1 2 3 4 4 3 2 1 -NOTICE- THIS DRAWING IS PROPRIETARY AND SHALL NOT BE COPIED OR ITS CONTENTS DISCLOSED TO OUTSIDE PARTIES WITHOUT THE WRITTEN CONSENT OF THE TRANE COMPANY A B C D D C B A REV.: DRAWING NO.: OF: SHEET: TITLE: PLOT SCALE: MFG. APPROVAL BY/DATE: ENG. APPROVAL BY/DATE: E.C.N. PRO-E ENTRY BY/DATE: LATEST E.C.N. NO.: APPROVAL: DESIGNED BY/DATE: PRO-E ENTRY BY/DATE: PRO-E FILE: CHECKED BY/DATE: THE TRANE COMPANY C B A 17.56 [446,1] 14.69 [373,0] 16.54 [420,0] .98 [25,0] 2.28 [58,0] 11.97 [304,0] A B C D1 FRAME 1154 [45.5] 1208 [47.5] 1166 [45.9] D2 FRAME 1535 [60.4] 1588 [62.4] 1545 [60.8] TIER 1 TIER 2 TIER 3 D1 WEIGHT 220 lbs [100 kg] 420 lbs [190 kg] 585 lbs [265 kg] D2 WEIGHT 320 lbs [450 kg] 575 lbs [260 kg] 950 lbs [431 kg] MTG,INSTRUCTIONS 174N3459 CONTROL CONDUITS ENTRY FOR NEMA TYPE 12 UNIT USE NEMA TYPE 12 CUNDUITS AND HUBS NOTES: 1. THIS ENCLOSURE CONFIGURATION USED FOR OPTION COMBINATIONS CONTAINING DRIVE FUSING / DRIVE DISCONNECT 2. AT MINIMUM THE TWO OUTSIDE LIFTING POINTS ARE REQUIRED WHEN HANDLING THIS UNIT. MN 10/17/08 1 5 MN 10/17/08 NONE A SAK 09/01/10 SP10100 NOTE 2 NOTE 2 POWER CONDUIT ENTRY/EXIT

Upload: others

Post on 09-Nov-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SCALE 0 - Danfoss

1234

4 3 2 1

-NOTICE-THIS DRAWING IS PROPRIETARY AND SHALL NOTBE COPIED OR ITS CONTENTS DISCLOSED TOOUTSIDE PARTIES WITHOUT THE WRITTEN

CONSENT OF THE TRANE COMPANY

A

B

C

D D

C

B

A

REV.:DRAWING NO.: OF:SHEET:

TITLE:

PLOT SCALE:

MFG. APPROVAL BY/DATE:

ENG. APPROVAL BY/DATE:

E.C.N. PRO-E ENTRY BY/DATE:LATEST E.C.N. NO.:

APPROVAL:

DESIGNED BY/DATE:

PRO-E ENTRY BY/DATE:

PRO-E FILE:

CHECKED BY/DATE:

THE TRANE COMPANY

CBA

17.56[446,1]

14.69[373,0]

16.54[420,0]

.98[25,0]

2.28[58,0]

11.97[304,0]

A B C

D1 FRAME 1154[45.5]

1208[47.5]

1166[45.9]

D2 FRAME 1535[60.4]

1588[62.4]

1545[60.8]

TIER 1 TIER 2 TIER 3

D1 WEIGHT 220 lbs[100 kg]

420 lbs[190 kg]

585 lbs[265 kg]

D2 WEIGHT 320 lbs[450 kg]

575 lbs[260 kg]

950 lbs[431 kg]

MTG,INSTRUCTIONS

174N3459

CONTROL CONDUITS ENTRYFOR NEMA TYPE 12 UNIT USE NEMATYPE 12 CUNDUITS AND HUBS

NOTES: 1. THIS ENCLOSURE CONFIGURATION USED FOR OPTION COMBINATIONS CONTAINING DRIVE FUSING / DRIVE DISCONNECT 2. AT MINIMUM THE TWO OUTSIDE LIFTING POINTS ARE REQUIRED WHEN HANDLING THIS UNIT.

MN 10/17/08

1 5

MN 10/17/08

NONE ASAK 09/01/10SP10100

SCALE 0.063

NOTE 2NOTE 2

POWER CONDUIT ENTRY/EXIT

Page 2: SCALE 0 - Danfoss

1234

4 3 2 1

-NOTICE-THIS DRAWING IS PROPRIETARY AND SHALL NOTBE COPIED OR ITS CONTENTS DISCLOSED TOOUTSIDE PARTIES WITHOUT THE WRITTEN

CONSENT OF THE TRANE COMPANY

A

B

C

D D

C

B

A

REV.:DRAWING NO.: OF:SHEET:

TITLE:

PLOT SCALE:

MFG. APPROVAL BY/DATE:

ENG. APPROVAL BY/DATE:

E.C.N. PRO-E ENTRY BY/DATE:LATEST E.C.N. NO.:

APPROVAL:

DESIGNED BY/DATE:

PRO-E ENTRY BY/DATE:

PRO-E FILE:

CHECKED BY/DATE:

THE TRANE COMPANY

ABC

2.11[53,6]

.98[25,0]

11.97[304,0]

16.54[420,0]

11.97[304,0]

14.69[373,0]

17.56[446,1]

33.07[840,0]

A B C

D1 FRAME 1154[45.5]

1208[47.5]

1166[45.9]

D2 FRAME 1535[60.4]

1588[62.4]

1545[60.8]

CONTROL CONDUITS ENTRYFOR NEMA TYPE 12 UNIT USENEMA TYPE 12 CONDUITS AND HUBS.

MTG,INSTRUCTIONS

174N3459

NOTES: 1. THIS ENCLOSURE CONFIGURATION USED FOR ALL OPTION COMBINATIONS EXCEPT BYPASS WITH DV/DT FILTER OR LINE REACTOR OR CONTACT MOTOR SELECT 2. AT MINIMUM THE TWO OUTSIDE LIFTING POINTS ARE REQUIRED WHEN HANDLING THIS UNIT.

2 5

MN 10/17/08

MN 10/17/08

NONE ASP10100

SCALE 0.062

SEE DETAIL B

NOTE 2NOTE 2 SEE DETAIL A

SAK 09/01/10

SEE DETAIL C

POWER CONDUIT ENTRY/EXIT

SEE DETAIL A

SEE DETAIL B

SEE DETAIL C

Page 3: SCALE 0 - Danfoss

1234

4 3 2 1

-NOTICE-THIS DRAWING IS PROPRIETARY AND SHALL NOTBE COPIED OR ITS CONTENTS DISCLOSED TOOUTSIDE PARTIES WITHOUT THE WRITTEN

CONSENT OF THE TRANE COMPANY

A

B

C

D D

C

B

A

REV.:DRAWING NO.: OF:SHEET:

TITLE:

PLOT SCALE:

MFG. APPROVAL BY/DATE:

ENG. APPROVAL BY/DATE:

E.C.N. PRO-E ENTRY BY/DATE:LATEST E.C.N. NO.:

APPROVAL:

DESIGNED BY/DATE:

PRO-E ENTRY BY/DATE:

PRO-E FILE:

CHECKED BY/DATE:

THE TRANE COMPANY

ABC

2.11[53,6]

.98[25,0]

11.97[304,0]

16.54[420,0]

11.97[304,0]

33.07[840,0]

11.97[304,0]

17.56[446,1]

49.61[1260,0]

14.69[373,0]

A B C

D1 FRAME 1154[45.5]

1208[47.5]

1166[45.9]

D2 FRAME 1535[60.4]

1588[62.4]

1545[60.8]

MTG,INSTRUCTIONS

174N3459

CONTROL CONDUITS ENTRYFOR NEMA TYPE 12 UNIT USENEMA TYPE 12 CONDUITS AND HUBS.

NOTES: 1. THIS ENCLOSURE CONFIGURATION USED FOR OPTION COMBINATIONS CONTAINING BYPASS WITH DV/DT FILTER OR LINE REACTOR OR CONTACT MOTOR SELECT 2. AT MINIMUM THE TWO OUTSIDE LIFTING POINTS ARE REQUIRED WHEN HANDLING THIS UNIT.

3 5

MN 10/17/08

ASP10100 SAK 09/01/10

SCALE 0.062

NOTE2

NOTE 2

MN 10/17/08

NONE

POWER CONDUIT ENTRY/EXITUSER OPTION DEPENDANT

Page 4: SCALE 0 - Danfoss

1234

4 3 2 1

-NOTICE-THIS DRAWING IS PROPRIETARY AND SHALL NOTBE COPIED OR ITS CONTENTS DISCLOSED TOOUTSIDE PARTIES WITHOUT THE WRITTEN

CONSENT OF THE TRANE COMPANY

A

B

C

D D

C

B

A

REV.:DRAWING NO.: OF:SHEET:

TITLE:

PLOT SCALE:

MFG. APPROVAL BY/DATE:

ENG. APPROVAL BY/DATE:

E.C.N. PRO-E ENTRY BY/DATE:LATEST E.C.N. NO.:

APPROVAL:

DESIGNED BY/DATE:

PRO-E ENTRY BY/DATE:

PRO-E FILE:

CHECKED BY/DATE:

THE TRANE COMPANY

8.86[225.0]

8.86[225.0]

8.86[225.0]

15.71[399.0]

2.11[53,6]

.98[25,0]

4X .4311,0[ ]

4X .4311,0[ ]

.9825,0[ ]

.87[22,0]

.98[25,0]

7.87[200,0]

14.96[380,0] .43

[11,0]

11.54[293,1]

13.94[354,0]

9.69[246,0]

R.287,0[ ]

SWING ANGLE105.0�$

MTG,INSTRUCTIONS

174N3459

VFD COOLING: THE VFD MUST BE INSTALLED VERTICALLY WITH THEMINIMUM FREE SPACE. ALL UL NEMA TYPE 1/IP21 AND NEMA TYPE 12/IP54 UNITS MAY BE MOUNTED SIDE BY SIDE, WITH NO MINIMUM SIDE CLEARANCE.

4 5

MN 10/17/08

MN 10/17/08

NONE ASP10100 SAK 09/01/10

DETAIL ALIFTING EYESCALE 0.250

DETAIL BTOP MOUNTING HOLES

SCALE 0.250

DETAIL CBOTTOM MOUNTING HOLES

SCALE 0.250

8X USE M10 MTG BOLT

CEILING

FLOOR

WALL MOUNTPEDESTAL MOUNT

CEILING

PEDESTALFLOOR MOUNT

Page 5: SCALE 0 - Danfoss

1234

4 3 2 1

-NOTICE-THIS DRAWING IS PROPRIETARY AND SHALL NOTBE COPIED OR ITS CONTENTS DISCLOSED TOOUTSIDE PARTIES WITHOUT THE WRITTEN

CONSENT OF THE TRANE COMPANY

A

B

C

D D

C

B

A

REV.:DRAWING NO.: OF:SHEET:

TITLE:

PLOT SCALE:

MFG. APPROVAL BY/DATE:

ENG. APPROVAL BY/DATE:

E.C.N. PRO-E ENTRY BY/DATE:LATEST E.C.N. NO.:

APPROVAL:

DESIGNED BY/DATE:

PRO-E ENTRY BY/DATE:

PRO-E FILE:

CHECKED BY/DATE:

THE TRANE COMPANY

460V

SERIES

FRAMEFC 302 FC 102/202

5000 (HO/NO) 4000/6000/8000

HP 125/150 150 D1KW 90/110 110 D1HP 150/200 200 D1KW 110/132 132 D1HP 200/250 250 D2KW 132/160 160 D2HP 250/300 300 D2KW 160/200 200 D2HP 300/350 350 D2KW 200/250 250 D2

600V

SERIES

FRAMEFC 302 FC 102/202

5000 (HO/NO) 4000/6000/8000

HP 75/100 100 D1KW 55/75 75 D1HP 100/125 125 D1KW 75/90 90 D1HP 125/150 150 D1KW 90/110 110 D1HP 150/200 200 D1KW 110/132 132 D1HP 200/250 250 D2KW 132/160 160 D2HP 250/300 300 D2KW 160/200 200 D2HP 300/350 350 D2KW 200/250 250 D2HP 350/400 400 D2KW 250/315 315 D2

174N3459

MTG,INSTRUCTIONS

MN 10/17/08