scale: 1 = 50'-0 l1 - nashvillemaps.nashville.gov/sp/2016/2016sp-043/sp_2016sp-043.pdf ·...

3
0 25 50 100 200 SCALE: 1" = 50'-0" 25 575 570 565 560 555 550 545 540 535 530 540 545 550 560 555 565 570 545 540 535 530 525 530 535 540 545 550 555 560 565 560 555 550 545 540 535 530 525 520 515 530 525 0 545 545 540 535 530 525 520 515 520 525 530 535 540 545 550 560 555 550 545 545 550 560 555 555 565 570 565 560 555 525 520 520 525 T-DEC REQUIRED STREAM BUFFERS TVA OVERHEAD POWERLINE EASEMENT SEWER EASEMENT 60'-0" 60'-0" OLD TRINITY TONEY ROAD MIXED USE BUILDING A 4 STORIES MAX. MULTI-FAMILY BUILDING B 4 STORIES MAX. MULTI-FAMILY BUILDING C 4 STORIES MAX. MIXED USE 4 STORIES MAX MIXED USE 4 STORIES MAX MIXED USE 4 STORIES MAX. MIXED USE 4 STORIES MAX. TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING SURFACE PARKING SURFACE PARKING SURFACE PARKING PRIVATE DRIVE B PRIVATE DRIVE A (PARKING) PRIVATE POCKET PARK POCKET PARK TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES SURFACE PARKED DETACHED COTTAGES ATTACHED GARAGE PARKING PRIVATE DRIVE B MIXED USE BUILDING A 4 STORIES MAX. MULTI-FAMILY BUILDING B 4 STORIES MAX. MULTI-FAMILY BUILDING C 4 STORIES MAX. TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES ATTACHED GARAGE PARKING TOWNHOUSES SURFACE PARKED DETACHED COTTAGES ATTACHED GARAGE PARKING PRIVATE DRIVE A (PARKING) DRIVE A (PARKING) ROAD TONEY EXTEN SION OPEN SPACE OPEN SPACE OPEN SPACE RS7.5 SINGLE FAMILY LOTS (MAX. 11 LOTS; TOTAL ACREAGE: 2.17) PRIVATE DRIVE B COMMUNITY GARDEN DETACHED COTTAGES ATTACHED GARAGE PARKING DETACHED COTTAGES ATTACHED GARAGE PARKING BLOCK 1 5.55 ACRES BLOCK 2 5.66 ACRES BLOCK 3 10.28 ACRES LANE 49' R.O.W. MATTHEWS ROAD 56' R.O.W. MANNING FAMILY PARTNERS, L.P. 7101007000 CASANOVA, JUAN CARLOS & VALVERDE, LORELI 7101006900 ROBERTS, DAYA R. 7101017900 SUCCESSFUL SURVIVORS 7101005800 YOKLEY, CLEVE ETUX 7101005600 ZAI'MAH, ABDUR-RAHIM ET UX 7101005500 ZAI'MAH, ABDUR R. & MARY 7101005400 BUTLER, HARVEY ETUX 7101010300 THE BANK OF NEW YORK MELLON, TRUSTEE 710101500 WALKER, MARVA E. PENDERGRASS & CHARLES 7101014400 WALKER, CHARLES JR. 7101014500 CRUTCHER, TOMMY O. ET UX 7101014600 CARTER, MARSHALL A.D. & DIANE L. 7101014700 BROWN, WILLIAM A. 7101014800 JARRETT, CYNTHIA R. & GARR, JOSEPH 7101002300 TURNER, E. MARK 7101002600 LIPSCOMB, RONALD L. & JEANINE O. 7101002800 LEVIN, AARON & ALLEN 7101002900 WILLIAMS, RONNIE & ANGELA 7101003000 WILLIAMS, RONNIE & ANGELA 7101003100 BROWN, LISA BROOKS 7101003200 WILLIAMS, VIRGINIA R. 7101003300 O'MALLEY, ROBERT A. REVOCABLE TRUST 7101003400 WOODRUFF, ANDREA 7101003500 BROWN, WILLIAM A., III 7101003600 TOWNSEND, PAMELA B. 7101003700 METRO GOVERNMENT 5916024800 SPANN, SANDRA B 7101000600 JAKES, KENNETH L. 7101001300 MOSS INVESTMENTS 7101001500 NEW COVENANT IN FAITH CHRISTIAN CHURCH, A 7105001500 PERMEABLE PAVERS LEGEND METRO GOVERNMENT S HAYNES 7105003100 SERVICE SERVICE SERVICE SERVICE SERVICE SERVICE SERVICE SERVICE SERVICE APPROXIMATE LOCATION OF BIORETENTION 8'-0" 12'-0" 12'-0" 12'-0" 12'-0" PROVIDE IMPROVEMENTS ON TRINITY LANE PER MCSP 13'-0" 13'-0" 4' 4' 5' 5' PROVIDE IMPROVEMENTS ON OLD MATTHEWS RD PER MCSP D-3 BUFFER WITH 6' OPAQUE FENCE T-DEC REQUIRED STREAM BUFFERS SERVICE INCLUDING TRASH / RECYCLING 5' WIDE WALKING TRAIL IN LIEU OF SIDEWALK ON THIS SIDE OF DRIVE LANDSCAPE BUFFER GRIZZARD, GIFFORD ET UX 7101000700 MCCLAIN, RAY 7101000802 ZIRKER, DOROTHY 7101000801 POSEY, WILLIAM H. & SUSIE J. 7101000901 POSEY, WILLIAM H. & SUSIE J. 7101000902 POSEY, WILLIAM H. & SUSIE J. 7101000903 SIDEWALK AND PLANTING STRIP CURB AND GUTTER 6' 6' 13'-6" 13'-6" 6' 6' 12' 11' 11' 11' 11' 8' 6' DRIVING LANES AND CENTER LANE SIDEWALK AND FURNISHING ZONE BIKE LANE, CURB AND GUTTER NORTH JOB NO.: 15-742 DATE: 4-28-16 SCALE: 1" = 50'-0" SHEET: TRINITY LANE MASTERPLAN NASHVILLE, TENNESSEE PRELIMINARY SP 300 1 5-17-16 2 5-31-16 3 6-7-16 L1.00 DESIGN TEAM DEVELOPER: AERIAL DEVELOPMENT GROUP CONTACT: JOSH RANDOLPH ADDRESS: 521 5TH AVENUE S. NASHVILLE, TN 37203 PHONE: 615.669.6785 E-MAIL: josh@aerialdevelopmentgroup .com LANDSCAPE ARCHITECT: HAWKINS PARTNERS, INC. CONTACT: KIM HAWKINS ADDRESS: 105 BROADWAY, SUITE 300 NASHVILLE, TN 37201 PHONE: 615.255.5218 E-MAIL: k.hawkins@hawkinspartners .com CIVIL ENGINEER: CIVIL SITE DESIGN GROUP CONTACT: SEAN DECOSTER ADDRESS: 630 SOUTHGATE AVENUE, SUITE A NASHVILLE, TN 37203 PHONE: 615.248.9999 E-MAIL: seand@civil-site .com PROPERTY INFORMATION COUNCIL DISTRICT: (2) DECOSTA HASTINGS PARCEL 21: PARCEL ID: 07101002100 ADDRESS: 0 TONEY ROAD NASHVILLE, TN 37207 OWNER: AERIAL INVESTMENT PROPERTIES , LLC 1100 Douglas Ave., Nashville, TN 37206 CURRENT ZONING: RS7.5 ACREAGE: 9.46 ACRES PARCEL 20: PARCEL ID: 07101002000 ADDRESS: 0 OLD MATHEWS ROAD NASHVILLE, TN 37207 OWNER: AERIAL INVESTMENT PROPERTIES , LLC 1100 Douglas Ave., Nashville, TN 37206 CURRENT ZONING: RS7.5 ACREAGE: 2.93 ACRES PARCEL 19: PARCEL ID: 07101001900 ADDRESS: 0 OLD MATHEWS ROAD NASHVILLE, TN 37207 OWNER: AERIAL INVESTMENT PROPERTIES , LLC 1100 Douglas Ave., Nashville, TN 37206 CURRENT ZONING: RS7.5 ACREAGE: 3.28 ACRES PARCEL 18: PARCEL ID: 07101001800 ADDRESS: 509 W. TRINITY LANE NASHVILLE, TN 37207 OWNER: AERIAL INVESTMENT PROPERTIES , LLC 1100 Douglas Ave., Nashville, TN 37206 CURRENT ZONING: RS7.5 ACREAGE: 2.75 ACRES PARCEL 17: PARCEL ID: 07101001700 ADDRESS: 511 W. TRINITY LANE NASHVILLE, TN 37207 OWNER: AERIAL INVESTMENT PROPERTIES , LLC 1100 Douglas Ave., Nashville, TN 37206 CURRENT ZONING: RS7.5 ACREAGE: 1.38 ACRES PARCEL 16A: PARCEL ID: 07101001600 ADDRESS: 513 W. TRINITY LANE NASHVILLE, TN 37207 OWNER: WOODS, JAMES L. & DARRYL T. 8625 Mill Chase Ct. CURRENT ZONING: RS7.5 ACREAGE: 1.32 ACRES PARCEL 16B: PARCEL ID: 07105001600 ADDRESS: 515 B W. TRINITY LANE NASHVILLE, TN 37207 OWNER: WOODS, J. L. ETUX 515 W Trinity Ln., Nashville, TN 37207 CURRENT ZONING: RS7.5 ACREAGE: .38 ACRES TOTAL SITE AREA: 21.5 ACRES R.O.W. DEDICATION: 1.43 ACRES (TONEY ROAD EXTENSION) PURPOSE THE PURPOSE OF THIS PLAN IS TO PROVIDE A MIXED USE INFILL DEVELOPMENT NODE WHICH SUPPORTS A VARIETY OF RESIDENTIAL USES ALONG A MAJOR ARTERIAL AND COLLECTOR STREET. ARCHITECTURE THE FINAL BUILDING ELEVATIONS SHALL BE SUBMITTED WITH THE FINAL SITE PLAN AND SHALL BE CONSISTENT WITH THE FOLLOWING ARCHITECTURAL STANDARDS: A. STOREFRONTS, RESTAURANTS, AND OFFICES SHALL BE ACTIVATED FROM, AND FRONT ONTO TRINITY LANE OR OLD MATTHEWS ROAD. B. MIXED USE BUILDINGS SHALL PROVIDE ACCESS VIA GLAZED DOORS FROM BOTH THE FRONT AND REAR OF THE STRUCTURE. C. FOR MIXED USE BUILDINGS ALONG TRINITY LANE, GROUND FLOORS SHALL INCLUDE A MINIMUM OF 40% GLAZING; ADDITIONAL STORIES SHALL INCLUDE A MINIMUM OF 25% GLAZING. D. THE MINIMUM GROUND FLOOR HEIGHT FOR EACH MIXED USED BUILDING SHALL BE 14'-0". E. ANY CORNER UNIT/BUILDING SHALL ADDRESS BOTH CORNERS; THIS SHALL BE ACCOMPLISHED VIA WRAP AROUND PORCHES, WINDOWS, BAY WINDOWS, OR OTHER FAÇADE PROJECTIONS. F. FOR TOWNHOMES, COTTAGES AND SINGLE FAMILY HOMES 1. BUILDING FACADES FACING A STREET, PROVIDE ONE PRINCIPAL ENTRANCE AND A MINIMUM OF 25% GLAZING. 2. WINDOWS SHALL BE VERTICALLY ORIENTED AT A RATIO OF 1:5;1 OR GREATER, EXCEPT FOR DORMERS OR EGRESS WINDOWS. 3. PORCHES SHALL PROVIDE A MINIMUM DEPTH OF SIX FEET. 4. A RAISED FOUNDATION WILL BE PROVIDED FOR A 2'-0" MINIMUM AND 5'-0" MAXIMUM HEIGHT ABOVE THE GRADE FOR THE FRONT FAÇADE. G. PROHIBITED MATERIALS: VINYL SIDING AND EIFS (EXTERIOR INSULATED FINISH SYSTEM) IS PROHIBITED ON ALL FACADES. UNCOATED CHAINLINK FENCING IS PROHIBITED. H. ALLOWED MATERIALS SHALL INCLUDE, BUT NOT BE LIMITED TO, FIBER CEMENTIOUS SIDING/PANELS , BRICK, STONE, CMU BLOCK AND CONCRETE FOR FOUNDATIONS, AND ARCHITECTURAL SHINGLES OR METAL FOR DECORATIVE SIDING OR SLOPED ROOFING. I. AWNINGS: FIRST FLOOR CANOPIES/AWNINGS ARE APPROPRIATE AT BUILDING ENTRANCES AND ABOVE STROEFRONTS AND SHALL NOT BE OF PLASTIC MATERIAL, NOR SHOULD THEY BE TRANSPARENT OR INTERNALLY ILLUMINATED. ENCROACHMENTS EXPOSED, COVERED, OR ENCLOSED PORCHES AND DECKS MAY EXTEND INTO FRONT, SIDE AND BACK SETBACKS OR COMMON SPACE NOT EXCEEDING 6FT INTO COMMON SPACE OR 3FT FROM PRIVATE LOT PROPERTY LINES. FRONT SETBACK ENCROACHMENTS ARE NOT PERMITTED ALONG OLD MATHEWS ROAD. REFER TO MUNICODE 17.12.040: OTHER SETBACKS FOR ALL OTHER ALLOWABLE ENCROACHMENTS NOT IDENTIFIED ABOVE. PARKING FINAL PARKING COUNT SHALL BE SUBJECT TO METRO ZONING PARKING REQUIREMENTS . GENERAL PLAN/COMMUNITY PLAN CONSISTENCY The Trinity Lane SP is consistent with the following policies within the Nashville Next Community Plan: T3-NE (Neighborhood Evolving) T3-CC (Suburban Community Center) The development indicates mixed use with commercial uses and higher density residential uses in the portion of the site policied as Suburban Community Center, providing a concentrated walkable development node to serve the community. The back portion of the undeveloped site is policied as T3- NE, as such, the development plan indicates a variety of infill housing types with sensitivity to the identified stream, drainageways and grades. LAND USE AND BLOCK DESIGNATIONS OVERALL DEVELOPMENT: MIXED USE: 25,000 S.F. MAXIMUM - shall be a combination of two or more of MUL-A / Artisan Manufacturing allowed uses RESIDENTIAL UNITS: 341 MAXIMUM - Apartments, 210 maximum units - Townhomes, 115 maximum units - Detached Cottages, 16 maximum units - Single Family residential lots, 11 maximum lots IMPERVIOUS SURFACE RATIO: .66 TOTAL PARKING REQUIRED: 679 spaces Mixed Use: 125 spaces (Based on general retail)* Residential: - Apartments, 210 max units / 30% 2bdrm, 70% 1bdrm = 272 bdrm / 272 sp req’d** - Townhomes, 115 maximum units / 2 spaces per unit / 230 spaces required - Detached Cottages, 16 maximum units / 2 spaces per unit / 32 spaces required - Single Family residential lots, 10 maximum lots / 2 spaces per unit / 20 spaces req'd * determination of commercial mix shall be submitted with Final SP. Shared parking to be provided in Block 1 based on mix of uses. ** estimated unit mix. Determination of unit mix shall be submitted with Final SP. TOTAL PARKING PROVIDED: 729 spaces Block 1 – 309 Block 2 – 247 Block 3 - 173 $ $ & $ " $ ' # ! '" )%( # % BLOCK 1: approximately 5 .55 ACRES BUILDING FRONTAGE FOR W. TRINITY LANE AND OLD MATHEWS: 50% MINIMUM MIXED USE BUILDING: 25,000 maximum GSF / .80 MAXIMUM FAR Uses Allowed: to Match MUL-A and including Artisan Manufacturing as defined by Ordinance No. BL2015-1121 Building Mass: Build To Zone / Trinity Lane: 5-20’** Build To Zone / Old Mathews: 0-10’** Side Setback: 0’ Rear Setback: 0’ Height Maximum: 4 stories Height Minimum: 16’ one story Parking: Provided per zoning code with shared parking available with Block 1 uses, / 125 spaces required (Based on general retail)* not including shared parking **outdoor dining areas are allowed to be zero setback provided that public sidewalk meeting MCSP is provided in adjacent public ROW. Build-to lines are subject to proximity of overhead power lines. MIXED USE BUILDING A: 54 – 70 dwelling units. This building may include square footage meeting the uses allowed under MUL-A and including Artisan Manufacturing as defined by Ordinance No. BL2015-1121, to the maximum of 25,000 GSF of that use allowed for Block 1 and for the overall development. Building Mass: Build To Zone / Old Matthews: 0-10’ Side Setback: 0’ Rear Setback: 0’ Height Maximum: 4 stories Height Minimum: 16’ one story Parking: Provided per zoning code with shared parking available with Block 1 uses. Based on 30% 2bdrm, 70% 1bdrm = 90 bdrm / 90 maximum sp req’d** RESIDENTIAL (attached townhomes): 40 dwelling units maximum Uses allowed: to Match MUL-A Building Mass: Private drive setback: 8-15’ from curb Side Setback: 0’ Rear Setback: 0’ Height Maximum: 2 stories, 35' on public street face. A third, exposed basement level shall be allowed, where needed, to accomodate site grade change. Parking: Provided per zoning code within attached garages or immediately adjacent surface parking / 2 spaces per unit / 80 spaces required Total Block 1 required parking: 295 spaces (not including shared parking reduction) Total Block 1 Parking provided: approximat ely 237 surface parking, plus 72 attached garage spaces / 309 provided BLOCK 2: approximately 5 .66 ACRES MULTI-FAMILY BUILDING B and C: 126 - 140 dwelling units Uses allowed: to Match RM20 Building Mass: Private drive setback: 12-15’ from curb Side Setback: 0’ Rear Setback: 0’ Height Maximum: 4 stories Parking: Provided per zoning code. Based on 30% 2bdrm, 70% 1bdrm = 182 bdrm / 182 maximum sp req’d** RESIDENTIAL (attached townhomes): 20 dwelling units maximum Uses allowed: to Match RM20 Building Mass: Private drive setback: 8-15’ from curb Side Setback: 0’ Rear Setback: 0’ Height Maximum: 2 stories, 35' on public street face. A third, exposed basement level shall be allowed, where needed, to accomodate site grade change. Parking: Provided per zoning code within attached garages / 2 spaces per unit / 40 spaces required RESIDENTIAL (detached cottages): 8- 10 dwelling units Uses allowed: to Match RM20 Building Mass: Street setback: 5-10’ Side Spacing: 6’ minimum between units Rear Setback: not applicable Height Maximum: 2 stories, 35' on public street face. A third, exposed basement level shall be allowed, where needed, to accomodate site grade change. Parking: Provided per zoning code within attached garages / 2 spaces per unit / 20 spaces required Total Block 2 required parking: 242 spaces Total Block 2 Parking provided: approximately 187 surface parking, plus 60 attached garage spaces / 247 provided BLOCK 3: approximately 10 .28 ACRES RESIDENTIAL (attached townhomes): 55 dwelling units maximum Uses allowed: to match RM20, plus non-commercial community gardening Building Mass: Public road setback: 0-10’ from property line Private drive setback: 8-15’ from curb Side Setback: 0’ Rear Setback: 0’ Height Maximum: 2 stories, 35' on public street face. A third, exposed basement level shall be allowed, where needed, to accomodate site grade change. Parking: Provided per zoning code within attached garages or immediately adjacent surface parking / 2 spaces per unit / 110 spaces required RESIDENTIAL (detached cottages): 5-6 dwelling units Uses allowed: to match RM20, plus non-commercial community gardening Building Mass: Street setback: 5-10’ Side Spacing: 6’ minimum between units Rear Setback: not applicable Height Maximum: 2 stories, 35' on public street face. A third, exposed basement level shall be allowed, where needed, to accomodate site grade change. Parking: Provided per zoning code within attached garages / 2 spaces per unit / 12 spaces required RESIDENTIAL (detached single family lots): 11 residential lots maximum Uses allowed: to Match RS7.5 Building Mass: Street setback: per RS7.5 standards Side Setback: per RS7.5 standards Rear Setback: per RS7.5 standards Height Maximum: per RS7.5standards Parking: No parking is permitted between the primary structure and street. Hard surfaces for vehicular access shall be limited to 16 feet . 2 spaces per unit / 22 spaces required Total Block 3 required parking: 144 spaces Total Block 3 Parking provided: approximately 61 surface parking, plus 114 attached garage spaces / 175 provided LANDSCAPE THE DEVELOPMENT OF THIS PROJECT SHALL COMPLY WITH THE REQUIREMENTS FOR METRO ZONING CODE CHAPTER 17.24 ARTICLE II: TREE PROTECTION AND REPLACEMENT, AND WITH CHAPTER 17.40 ARTICLE X: TREE PROTECTION AND REPLACEMENT PROCEDURES. DETAILED LANDSCAPE ORDINANCE PLAN TO BE SUBMITTED WITH THE FINAL SP SUBMITTAL. A D-3 LANDSCAPE BUFFER PLUS A 6’ OPAQUE FENCE IS PROVIDED AT THE REAR OF SINGLE FAMILY LOTS ALONG OLD MATHEWS ROAD BETWEEN THE TVA LINE AND THE TONEY ROAD R.O.W. AS INDICATED. NO OTHER LANDSCAPE BUFFERS ARE PROVIDED. SOIL CLASSIFICATIONS BARFIELD ROCK OUTCROP COMPLEX (5-20% SLOPES) MIMOSA - URBAN LAND COMPLEX (5-25% SLOPES) ROADWAY CLASSIFICATIONS TRINITY LANE: T3-M-AB5 OLD MATHEWS ROAD: T3-R-CA2 TONEY ROAD: LOCAL STREET REFER TO TRAFFIC IMPACT STUDY, PREPARED BY FISCHBACH TRANSPORTATION GROUP, LLC AND DATED APRIL 2016 GENERAL NOTES ALL EXISTING STRUCTURES ON THESE PARCELS TO BE DEMOLISHED . ALL DEVELOPMENT WITHIN THE BOUNDARIES OF THIS PLAN MEETS THE REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT AND FAIR HOUSING ACT. THIS PROPERTY DOES NOT LIE WITHIN AN AREA DESIGNATED AS SPECIAL FLOOD HAZARD AREA ACCORDING TO FEDERAL EMERGENCY MANAGEMENT AGENCY FLOOD INSURANCE MAPS. (REFER TO CIVIL PLAN) TRASH AND RECYCLING SERVICES TO BE CONTRACTED BETWEEN THE DEVELOPER/OWNER AND A PRIVATE HAULER FOR ALL UNITS ON PRIVATE DRIVES. SINGLE FAMILY LOTS TO BE SERVICES BY METRO PUBLIC WORKS. USPS MAIL DELIVERY WILL BE PROVIDED BY CENTRALIZED KIOSKS/MAIL ROOMS WITHIN COMMERICAL AND MULTI-FAMILY BUILDINGS AND BY INDIVIDUAL MAILBOXES SERVICED FROM THE DRIVES/ALLEYS AND ROADS FOR OTHER RESIDENTIAL USES. THE FINAL SITE PLAN/BUILDING PERMIT SITE PLAN SHALL DEPICT A MINIMUM 5 FOOT CLEAR PATH OF TRAVEL FOR PEDESTRIAN WAYS, INCLUDING PUBLIC SIDEWALKS, AND THE LOCATION OF ALL EXISITNG AND PROPOSED OBSTRUCTIONS . PRIOR TO THE ISSUANCE OF USE AND OCCUPANCY PERMITS, EXISITNG OBSTRUCTIONS, INCLUDING POWER POLES AND SIGNAGE, WITHIN THE PATH OF TRAVEL SHALL BE RELOCATED TO PROVIDE A MINIMUM OF 5’ OF CLEAR ACCESS. SIDEWALKS ALONG TRINITY LANE AND OLD MATHEWS ROAD SHALL BE PER MCSP. THE SIDEWALK ALONG TONEY ROAD SHALL BE 5’ IN WIDTH MEETING THE PUBLIC WORKS STANDARD ST-210, AND INCLUDE A 4’ PLANTING STRIP. THE CURB AND GUTTER ALONG TONEY ROAD TO MEET THE PUBLIC WORKS STANDARD ST-200. STORMWATER/UTILITIES/INFRASTRUCTURE: STORMWATER PLANS FOR THIS DEVELOPMENT TO BE PROVIDED IN A MANNER CONSISTENT WITH THE STORMWATER VOLUME 5 LID MANUAL. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES TO INDICATE THE BASIC PREMISE OF THIS DEVELOPMENT AND PROPOSED STORMWATER LOCATIONS AND METHODS. FINAL DETIALS SHALL BE GOVERNED BY THE APPROPRIATE REGULATIONS AT THE TIEM OF THE SUBMITTAL. SIZE DRIVEWAY CULVERTS PER THE DESIGN CRITERIA SET FORTH BY METRO STORMWATER MANAGEMENT MANUAL. METRO WATER SERVICES SHALL BE PROVIDED SUFFICIENT AND UNENCUMBERED ACCESS IN ORDER TO MAINTAIN AND REPAIR UTILITIES ON THE SITE. ALL WATER AND SEWER CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE SPECIFICAITONS ANDSTNDARD DETAILS OF METRO WATER SERVICES. ALL ABOVE GROUND UTILITY BOXES/DEVICES WILL BE SCREENED APPROPRIATELY. ALL PROPOSED NEW PUBLIC UTILITIES AND SERVICES SHALL BE INSTALLED UNDERGROUND. ALL ACCESS DRIVES AND DRIVEWAYS WITHIN THIS DEVELOPMENT, WITH THE EXCEPTION OF TONEY ROAD, SHALL BE PRIVATE. ALL PRIVATE DRIVES/ALLEYS MAY BE PAVED WITH PERVIOUS PAVEMENT WITH MATERIAL AND CROSS-SECTION TO BE APPROVED BY METRO PUBLIC WORKS. NO FRONT-LOADED GARAGES ARE PERMITTED ON A PUBLIC ROAD. ALL SIDEWALKS LOCATED WITHIN THE PUBLIC R.O.W. ARE TO MEET METRO PUBLIC WORKS AND ADA STANDARDS. BUFFER FOR ON SITE STREAMS INDICATED IN ACCORDANCE WITH AQUATIC RESOURCE ASSESSMENT PERFORMED BY BDY DATED MARCH, 23, 2016. NO DEFINED TOP OF BANK WAS INDICATED FOR THS STREAM SECTION. REFER TO CIVIL DRAWINGS FOR ALL OTHER UTILITIES/ EASEMENTS. SITE W. TRINITY LN WHITES CREEK PIKE VICINITY MAP SP CASE NO.: 2016SP-043-001

Upload: others

Post on 12-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

0 25 50 100 200

SCALE: 1" = 50'-0"

25

575

57

0

5655605555

50545

540

535

530

540

545

550

560

555

565

570

545

54

0

535

530

525

530

535

540

545

550

555

560

565

560

555

550

545

540

535

530

525

520

515

530

525

0

545

545

540

535

530

525

520515

520

525

530

535

540

545

550

560

555

550

545

545

550

560

555

555

565

570

565560

555

525

520

520

525

T-DEC REQUIRED STREAM BUFFERS

TVA OVERHEAD POWERLINE EASEMENT

SEWER EASEMENT

60'-0"

60'-0"

OLDTRIN

ITY

TONEY ROAD

MIXED USE BUILDING A

4 STORIES MAX.

MU

LT

I-FA

MIL

Y B

UIL

DIN

G B

4 S

TO

RIE

S M

AX

.

MULTI-FAMILY BUILDING C

4 STORIES MAX.

MIX

ED

US

E

4 S

TO

RIE

S M

AX

MIX

ED

US

E

4 S

TO

RIE

S M

AX

MIX

ED

USE

4 STO

RIE

S M

AX.

MIX

ED

USE

4 STO

RIE

S M

AX.

TOWNHOUSES

ATTACHED GARAGE PARKING

TOWNHOUSES

ATTACHED GARAGE PARKING

TOW

NHOUSES

ATTACHED

GARAG

E PARKIN

G

TOWNHOUSES

ATTACHED GARAGE PARKING

TO

WN

HO

US

ES

AT

TA

CH

ED

GA

RA

GE

PA

RK

ING

SURFACE PARKING

SURFA

CE P

ARKIN

G

SURFACE PARKING

PRIVATE DRIVE B

PRIVATE DRIVE A (PARKING)

PRIVATE

POCKET

PARK

POCKET

PARK

TO

WN

HO

US

ES

AT

TA

CH

ED

GA

RA

GE

PA

RK

ING

TO

WN

HO

US

ES

AT

TA

CH

ED

GA

RA

GE

PA

RK

ING

TO

WN

HO

US

ES

AT

TA

CH

ED

GA

RA

GE

PA

RK

ING

TO

WN

HO

US

ES

ATTA

CH

ED

GA

RA

GE

PA

RK

ING

TO

WN

HO

US

ES

ATTA

CH

ED

GA

RA

GE

PA

RK

ING

TO

WN

HO

US

ES

ATTA

CH

ED

GA

RA

GE

PA

RK

ING

TOWNHOUSES

ATTACHED GARAGE PARKING

TOWNHOUSES

SURFACE PARKED

DETACHED COTTAGES

ATTACHED GARAGE PARKING

PRIVATE DRIVE B

MIXED USE BUILDING A

4 STORIES MAX.

MU

LT

I-FA

MIL

Y B

UIL

DIN

G B

4 S

TO

RIE

S M

AX

.

MULTI-FAMILY BUILDING C

4 STORIES MAX.

TOWNHOUSES

ATTACHED GARAGE PARKING

TOWNHOUSES

ATTACHED GARAGE PARKING

TOW

NHOUSES

ATTACHED

GARAG

E PARKIN

G

TOWNHOUSES

ATTACHED GARAGE PARKING

TO

WN

HO

US

ES

AT

TA

CH

ED

GA

RA

GE

PA

RK

ING

TO

WN

HO

US

ES

AT

TA

CH

ED

GA

RA

GE

PA

RK

ING

TO

WN

HO

US

ES

AT

TA

CH

ED

GA

RA

GE

PA

RK

ING

TO

WN

HO

US

ES

AT

TA

CH

ED

GA

RA

GE

PA

RK

ING

TO

WN

HO

US

ES

ATTA

CH

ED

GA

RA

GE

PA

RK

ING

TO

WN

HO

US

ES

ATTA

CH

ED

GA

RA

GE

PA

RK

ING

TO

WN

HO

US

ES

ATTA

CH

ED

GA

RA

GE

PA

RK

ING

TOWNHOUSES

ATTACHED GARAGE PARKING

TOWNHOUSES

SURFACE PARKED

DETACHED COTTAGES

ATTACHED GARAGE PARKING

PR

IVA

TE

DR

IVE

A (P

AR

KIN

G)

DRIVE A

(PARKING)

ROAD

TO

NE

Y

EX

TEN

SIO

N

OPEN SPACE

OPEN SPACE

OPEN SPACE

RS7.5 SINGLEFAMILY LOTS

(MAX. 11 LOTS;TOTAL ACREAGE: 2.17)

PR

IVA

TE

DR

IVE

B

CO

MM

UN

ITY

GA

RD

EN

DETACHED COTTAGES

ATTACHED GARAGE PARKING

DETACHED COTTAGES

ATTACHED GARAGE PARKING

BLOCK 1

5.55 ACRES

BLOCK 2

5.66 ACRES

BLOCK 3

10.28 ACRES

LA

NE

49' R

.O.W

.

MATTHEWS ROAD56' R.O.W.

MANNING FAMILYPARTNERS, L.P.

7101007000

CASANOVA, JUAN CARLOS& VALVERDE, LORELI

7101006900

ROBERTS, DAYA R.7101017900

SUCCESSFULSURVIVORS7101005800

YOKLEY, CLEVE ETUX7101005600

ZAI'MAH, ABDUR-RAHIM ET UX7101005500

ZAI'MAH, ABDUR R.& MARY

7101005400

BUTLER, HARVEY ETUX7101010300

THE BANK OF NEW YORKMELLON, TRUSTEE

710101500

WALKER, MARVA E.PENDERGRASS &

CHARLES7101014400 WALKER,

CHARLES JR.7101014500

CRUTCHER,TOMMY O. ET UX

7101014600

CARTER, MARSHALLA.D. & DIANE L.

7101014700

BROWN,WILLIAM A.7101014800

JARRETT, CYNTHIA R. &GARR, JOSEPH

7101002300

TURNER, E. MARK7101002600

LIPSCOMB, RONALD L.& JEANINE O.7101002800

LEVIN, AARON & ALLEN7101002900

WILLIAMS, RONNIE &ANGELA

7101003000

WILLIAMS, RONNIE &ANGELA

7101003100

BROWN, LISA BROOKS7101003200

WILLIAMS, VIRGINIA R.7101003300

O'MALLEY, ROBERT A.REVOCABLE TRUST

7101003400

WOODRUFF, ANDREA7101003500

BROWN, WILLIAM A., III7101003600

TOWNSEND, PAMELA B.7101003700

METRO GOVERNMENT5916024800SPANN,

SANDRA B7101000600

JAKES, KENNETH L.7101001300

MOSS INVESTMENTS7101001500

NEW COVENANT IN FAITHCHRISTIAN CHURCH, A

7105001500

PERMEABLE PAVERS

LEGEND

METROGOVERNMENT S

HAYNES7105003100

SERVICE

SERVICE

SERVICE

SERVICE

SERVICE

SERVICE

SERVICE

SERVICE

SE

RV

ICE

APPROXIMATE LOCATION OF BIORETENTION

8'-0"12'-0" 12'-0"

12'-0

"12'-0

"

PR

OV

IDE

IMP

RO

VE

ME

NTS

ON

TR

INIT

Y L

AN

E P

ER

MC

SP

13'-0"

13'-0"

4'

4' 5'

5'

PROVIDE IMPROVEMENTS ON

OLD MATTHEWS RD

PER MCSP

D-3 BUFFER WITH 6' OPAQUE

FENCE

T-DEC REQUIREDSTREAM BUFFERS

SERVICE INCLUDING TRASH / RECYCLING

5' WIDE WALKING TRAIL IN LIEU OF SIDEWALK ON THIS SIDE OF DRIVE

LANDSCAPE BUFFER

GRIZZARD,GIFFORD ET UX

7101000700

MCCLAIN, RAY7101000802

ZIRKER,DOROTHY

7101000801

POSEY,WILLIAM H.& SUSIE J.

7101000901

POSEY,WILLIAM H.& SUSIE J.7101000902

POSEY,WILLIAM H.& SUSIE J.

7101000903

SIDEWALK AND PLANTING STRIP

CURB AND GUTTER

6'

6'

13'-6

"13'-6

"6'

6'

12'11' 11'

11'11'

8'6'DRIVING LANES AND CENTER LANE

SIDEWALK AND FURNISHING ZONE

BIKE LANE, CURB AND GUTTER

NORTH

JOB NO.: 15-742

DATE: 4-28-16

SCALE: 1" = 50'-0"

SHEET:

TRIN

ITY

LA

NE

MA

STER

PLA

NN

ASH

VIL

LE, T

ENN

ESSE

E

PR

ELIM

INA

RY

SP

300

1 5-17-16

2 5-31-16

3 6-7-16

L1.00

DESIGN TEAMDEVELOPER: AERIAL DEVELOPMENT GROUPCONTACT: JOSH RANDOLPHADDRESS: 521 5TH AVENUE S.

NASHVILLE, TN 37203PHONE: 615.669.6785E-MAIL: josh@aerialdevelopmentgroup .com

LANDSCAPEARCHITECT: HAWKINS PARTNERS, INC.CONTACT: KIM HAWKINSADDRESS: 105 BROADWAY, SUITE 300

NASHVILLE, TN 37201PHONE: 615.255.5218E-MAIL: k.hawkins@hawkinspartners .com

CIVIL ENGINEER: CIVIL SITE DESIGN GROUPCONTACT: SEAN DECOSTERADDRESS: 630 SOUTHGATE AVENUE, SUITE A

NASHVILLE, TN 37203PHONE: 615.248.9999

E-MAIL: seand@civil-site .com

PROPERTY INFORMATIONCOUNCIL DISTRICT: (2) DECOSTA HASTINGS

PARCEL 21: PARCEL ID: 07101002100 ADDRESS: 0 TONEY ROAD

NASHVILLE, TN 37207 OWNER: AERIAL INVESTMENT PROPERTIES, LLC

1100 Douglas Ave., Nashville, TN 37206 CURRENT ZONING: RS7.5 ACREAGE: 9.46 ACRES

PARCEL 20: PARCEL ID: 07101002000 ADDRESS: 0 OLD MATHEWS ROAD

NASHVILLE, TN 37207 OWNER: AERIAL INVESTMENT PROPERTIES, LLC

1100 Douglas Ave., Nashville, TN 37206 CURRENT ZONING: RS7.5 ACREAGE: 2.93 ACRES

PARCEL 19: PARCEL ID: 07101001900 ADDRESS: 0 OLD MATHEWS ROAD

NASHVILLE, TN 37207 OWNER: AERIAL INVESTMENT PROPERTIES, LLC

1100 Douglas Ave., Nashville, TN 37206 CURRENT ZONING: RS7.5 ACREAGE: 3.28 ACRES

PARCEL 18: PARCEL ID: 07101001800 ADDRESS: 509 W. TRINITY LANE

NASHVILLE, TN 37207 OWNER: AERIAL INVESTMENT PROPERTIES, LLC

1100 Douglas Ave., Nashville, TN 37206 CURRENT ZONING: RS7.5 ACREAGE: 2.75 ACRES

PARCEL 17: PARCEL ID: 07101001700 ADDRESS: 511 W. TRINITY LANE

NASHVILLE, TN 37207 OWNER: AERIAL INVESTMENT PROPERTIES, LLC

1100 Douglas Ave., Nashville, TN 37206 CURRENT ZONING: RS7.5 ACREAGE: 1.38 ACRES

PARCEL 16A: PARCEL ID: 07101001600 ADDRESS: 513 W. TRINITY LANE

NASHVILLE, TN 37207 OWNER: WOODS, JAMES L. & DARRYL T. 8625 Mill Chase Ct. CURRENT ZONING: RS7.5 ACREAGE: 1.32 ACRES

PARCEL 16B: PARCEL ID: 07105001600 ADDRESS: 515 B W. TRINITY LANE

NASHVILLE, TN 37207 OWNER: WOODS, J. L. ETUX

515 W Trinity Ln., Nashville, TN 37207 CURRENT ZONING: RS7.5 ACREAGE: .38 ACRES

TOTAL SITE AREA: 21.5 ACRES

R.O.W. DEDICATION: 1.43 ACRES (TONEY ROAD EXTENSION)

PURPOSETHE PURPOSE OF THIS PLAN IS TO PROVIDE A MIXED USE INFILL DEVELOPMENT NODE WHICH SUPPORTS A VARIETY OF RESIDENTIAL USES ALONG A MAJOR ARTERIAL AND COLLECTOR STREET.

ARCHITECTURETHE FINAL BUILDING ELEVATIONS SHALL BE SUBMITTED WITH THE FINAL SITE PLAN AND SHALL BE CONSISTENT WITH THE FOLLOWING ARCHITECTURAL STANDARDS:

A. STOREFRONTS, RESTAURANTS, AND OFFICES SHALL BE ACTIVATED FROM, AND FRONT ONTO TRINITY LANE OR OLD MATTHEWS ROAD.

B. MIXED USE BUILDINGS SHALL PROVIDE ACCESS VIA GLAZED DOORS FROM BOTH THE FRONT AND REAR OF THE STRUCTURE.

C. FOR MIXED USE BUILDINGS ALONG TRINITY LANE, GROUND FLOORS SHALL INCLUDE A MINIMUM OF 40% GLAZING; ADDITIONAL STORIES SHALL INCLUDE A MINIMUM OF 25% GLAZING.

D. THE MINIMUM GROUND FLOOR HEIGHT FOR EACH MIXED USED BUILDING SHALL BE 14'-0".

E. ANY CORNER UNIT/BUILDING SHALL ADDRESS BOTH CORNERS; THIS SHALL BE ACCOMPLISHED VIA WRAP AROUND PORCHES, WINDOWS, BAY WINDOWS, OR OTHER FAÇADE PROJECTIONS.

F. FOR TOWNHOMES, COTTAGES AND SINGLE FAMILY HOMES

1. BUILDING FACADES FACING A STREET, PROVIDE ONE PRINCIPAL ENTRANCE AND A MINIMUM OF 25% GLAZING.

2. WINDOWS SHALL BE VERTICALLY ORIENTED AT A RATIO OF 1:5;1 OR GREATER, EXCEPT FOR DORMERS OR EGRESS WINDOWS.

3. PORCHES SHALL PROVIDE A MINIMUM DEPTH OF SIX FEET.

4. A RAISED FOUNDATION WILL BE PROVIDED FOR A 2'-0" MINIMUM AND 5'-0" MAXIMUM HEIGHT ABOVE THE GRADE FOR THE FRONT FAÇADE.

G. PROHIBITED MATERIALS: VINYL SIDING AND EIFS (EXTERIOR INSULATED FINISH SYSTEM) IS PROHIBITED ON ALL FACADES. UNCOATED CHAINLINK FENCING IS PROHIBITED.

H. ALLOWED MATERIALS SHALL INCLUDE, BUT NOT BE LIMITED TO, FIBER CEMENTIOUS SIDING/PANELS, BRICK, STONE, CMU BLOCK AND CONCRETE FOR FOUNDATIONS, AND ARCHITECTURAL SHINGLES OR METAL FOR DECORATIVE SIDING OR SLOPED ROOFING.

I. AWNINGS: FIRST FLOOR CANOPIES/AWNINGS ARE APPROPRIATE AT BUILDING ENTRANCES AND ABOVE STROEFRONTS AND SHALL NOT BE OF PLASTIC MATERIAL, NOR SHOULD THEY BE TRANSPARENT OR INTERNALLY ILLUMINATED.

ENCROACHMENTSEXPOSED, COVERED, OR ENCLOSED PORCHES AND DECKS MAY EXTEND INTO FRONT, SIDE AND BACK SETBACKS OR COMMON SPACE NOT EXCEEDING 6FT INTO COMMON SPACE OR 3FT FROM PRIVATE LOT PROPERTY LINES. FRONT SETBACK ENCROACHMENTS ARE NOT PERMITTED ALONG OLD MATHEWS ROAD.

REFER TO MUNICODE 17.12.040: OTHER SETBACKS FOR ALL OTHER ALLOWABLE ENCROACHMENTS NOT IDENTIFIED ABOVE.

PARKINGFINAL PARKING COUNT SHALL BE SUBJECT TO METRO ZONING PARKING REQUIREMENTS.

GENERAL PLAN/COMMUNITY PLAN CONSISTENCYThe Trinity Lane SP is consistent with the following policies within the Nashville Next Community Plan:T3-NE (Neighborhood Evolving)T3-CC (Suburban Community Center)

The development indicates mixed use with commercial uses and higher density residential uses in the portion of the site policied as Suburban Community Center, providing a concentrated walkable development node to serve the community.The back portion of the undeveloped site is policied as T3- NE, as such, the development plan indicates a variety of infill housing types with sensitivity to the identified stream, drainageways and grades.

LAND USE AND BLOCK DESIGNATIONSOVERALL DEVELOPMENT:

MIXED USE: 25,000 S.F. MAXIMUM - shall be a combination of two or more of MUL-A / Artisan Manufacturing allowed usesRESIDENTIAL UNITS: 341 MAXIMUM - Apartments, 210 maximum units - Townhomes, 115 maximum units - Detached Cottages, 16 maximum units - Single Family residential lots, 11 maximum lots

IMPERVIOUS SURFACE RATIO: .66

TOTAL PARKING REQUIRED: 679 spacesMixed Use: 125 spaces (Based on general retail)*Residential: - Apartments, 210 max units / 30% 2bdrm, 70% 1bdrm = 272 bdrm / 272 sp req’d** - Townhomes, 115 maximum units / 2 spaces per unit / 230 spaces required - Detached Cottages, 16 maximum units / 2 spaces per unit / 32 spaces required - Single Family residential lots, 10 maximum lots / 2 spaces per unit / 20 spaces req'd* determination of commercial mix shall be submitted with Final SP. Shared parking to be provided in Block 1 based on mix of uses.** estimated unit mix. Determination of unit mix shall be submitted with Final SP.

TOTAL PARKING PROVIDED: 729 spaces Block 1 – 309 Block 2 – 247 Block 3 - 173

BLOCK 1: approximately 5.55 ACRESBUILDING FRONTAGE FOR W. TRINITY LANE AND OLD MATHEWS: 50% MINIMUM

MIXED USE BUILDING:25,000 maximum GSF / .80 MAXIMUM FAR Uses Allowed: to Match MUL-A and including Artisan Manufacturing as defined by Ordinance No. BL2015-1121Building Mass: Build To Zone / Trinity Lane: 5-20’** Build To Zone / Old Mathews: 0-10’** Side Setback: 0’ Rear Setback: 0’ Height Maximum: 4 stories Height Minimum: 16’ one storyParking: Provided per zoning code with shared parking available with Block 1 uses, / 125 spaces required (Based on general retail)* not including shared parking**outdoor dining areas are allowed to be zero setback provided that public sidewalk meeting MCSP is provided in adjacent public ROW. Build-to lines are subject to proximity of overhead power lines.

MIXED USE BUILDING A:54 – 70 dwelling units. This building may include square footage meeting the uses allowed under MUL-A and including Artisan Manufacturing as defined by Ordinance No. BL2015-1121, to the maximum of 25,000 GSF of that use allowed for Block 1 and for the overall development.Building Mass: Build To Zone / Old Matthews: 0-10’ Side Setback: 0’ Rear Setback: 0’ Height Maximum: 4 stories Height Minimum: 16’ one storyParking: Provided per zoning code with shared parking available with Block 1 uses. Based on 30% 2bdrm, 70% 1bdrm = 90 bdrm / 90 maximum sp req’d**

RESIDENTIAL (attached townhomes):40 dwelling units maximumUses allowed: to Match MUL-ABuilding Mass: Private drive setback: 8-15’ from curb Side Setback: 0’ Rear Setback: 0’ Height Maximum: 2 stories, 35' on public street face. A third, exposed basement level shall be allowed, where needed, to accomodate site grade change.Parking: Provided per zoning code within attached garages or immediately adjacent surface parking / 2 spaces per unit / 80 spaces required

Total Block 1 required parking: 295 spaces (not including shared parking reduction)Total Block 1 Parking provided: approximately 237 surface parking, plus 72 attached garage spaces / 309 provided

BLOCK 2: approximately 5.66 ACRES

MULTI-FAMILY BUILDING B and C:126 - 140 dwelling unitsUses allowed: to Match RM20Building Mass: Private drive setback: 12-15’ from curb Side Setback: 0’ Rear Setback: 0’ Height Maximum: 4 storiesParking: Provided per zoning code. Based on 30% 2bdrm, 70% 1bdrm = 182 bdrm / 182 maximum sp req’d**

RESIDENTIAL (attached townhomes):20 dwelling units maximumUses allowed: to Match RM20Building Mass: Private drive setback: 8-15’ from curb Side Setback: 0’ Rear Setback: 0’ Height Maximum: 2 stories, 35' on public street face. A third, exposed basement level shall be allowed, where needed, to accomodate site grade change.Parking: Provided per zoning code within attached garages / 2 spaces per unit / 40 spaces required

RESIDENTIAL (detached cottages):8- 10 dwelling units Uses allowed: to Match RM20Building Mass: Street setback: 5-10’Side Spacing: 6’ minimum between units Rear Setback: not applicable Height Maximum: 2 stories, 35' on public street face. A third, exposed basement level shall be allowed, where needed, to accomodate site grade change.Parking: Provided per zoning code within attached garages / 2 spaces per unit / 20 spaces required

Total Block 2 required parking: 242 spaces Total Block 2 Parking provided: approximately 187 surface parking, plus 60 attached garage spaces / 247 provided

BLOCK 3: approximately 10.28 ACRES

RESIDENTIAL (attached townhomes):55 dwelling units maximumUses allowed: to match RM20, plus non-commercial community gardeningBuilding Mass: Public road setback: 0-10’ from property line Private drive setback: 8-15’ from curb Side Setback: 0’ Rear Setback: 0’ Height Maximum: 2 stories, 35' on public street face. A third, exposed basement level shall be allowed, where needed, to accomodate site grade change. Parking: Provided per zoning code within attached garages or immediately adjacent surface parking / 2 spaces per unit / 110 spaces required

RESIDENTIAL (detached cottages):5-6 dwelling units Uses allowed: to match RM20, plus non-commercial community gardeningBuilding Mass: Street setback: 5-10’ Side Spacing: 6’ minimum between units Rear Setback: not applicable Height Maximum: 2 stories, 35' on public street face. A third, exposed basement level shall be allowed, where needed, to accomodate site grade change. Parking: Provided per zoning code within attached garages / 2 spaces per unit / 12 spaces required

RESIDENTIAL (detached single family lots):11 residential lots maximumUses allowed: to Match RS7.5Building Mass: Street setback: per RS7.5 standards Side Setback: per RS7.5 standards Rear Setback: per RS7.5 standards Height Maximum: per RS7.5standards

Parking: No parking is permitted between the primary structure and street. Hard surfaces for vehicular access shall be limited to 16 feet. 2 spaces per unit / 22 spaces required

Total Block 3 required parking: 144 spaces Total Block 3 Parking provided: approximately 61 surface parking, plus 114 attached garage spaces / 175 provided

LANDSCAPETHE DEVELOPMENT OF THIS PROJECT SHALL COMPLY WITH THE REQUIREMENTS FOR METRO ZONING CODE CHAPTER 17.24 ARTICLE II: TREE PROTECTION AND REPLACEMENT, AND WITH CHAPTER 17.40 ARTICLE X: TREE PROTECTION AND REPLACEMENT PROCEDURES. DETAILED LANDSCAPE ORDINANCE PLAN TO BE SUBMITTED WITH THE FINAL SP SUBMITTAL.

A D-3 LANDSCAPE BUFFER PLUS A 6’ OPAQUE FENCE IS PROVIDED AT THE REAR OF SINGLE FAMILY LOTS ALONG OLD MATHEWS ROAD BETWEEN THE TVA LINE AND THE

TONEY ROAD R.O.W. AS INDICATED. NO OTHER LANDSCAPE BUFFERS ARE PROVIDED.

SOIL CLASSIFICATIONSBARFIELD ROCK OUTCROP COMPLEX (5-20% SLOPES)MIMOSA - URBAN LAND COMPLEX (5-25% SLOPES)

ROADWAY CLASSIFICATIONSTRINITY LANE: T3-M-AB5OLD MATHEWS ROAD: T3-R-CA2TONEY ROAD: LOCAL STREET

REFER TO TRAFFIC IMPACT STUDY, PREPARED BY FISCHBACH TRANSPORTATION GROUP, LLC AND DATED APRIL 2016

GENERAL NOTESALL EXISTING STRUCTURES ON THESE PARCELS TO BE DEMOLISHED.

ALL DEVELOPMENT WITHIN THE BOUNDARIES OF THIS PLAN MEETS THE REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT AND FAIR HOUSING ACT.

THIS PROPERTY DOES NOT LIE WITHIN AN AREA DESIGNATED AS SPECIAL FLOOD HAZARD AREA ACCORDING TO FEDERAL EMERGENCY MANAGEMENT AGENCY FLOOD INSURANCE MAPS. (REFER TO CIVIL PLAN)

TRASH AND RECYCLING SERVICES TO BE CONTRACTED BETWEEN THE DEVELOPER/OWNER AND A PRIVATE HAULER FOR ALL UNITS ON PRIVATE DRIVES. SINGLE FAMILY LOTS TO BE SERVICES BY METRO PUBLIC WORKS.

USPS MAIL DELIVERY WILL BE PROVIDED BY CENTRALIZED KIOSKS/MAIL ROOMS WITHIN COMMERICAL AND MULTI-FAMILY BUILDINGS AND BY INDIVIDUAL MAILBOXES SERVICED FROM THE DRIVES/ALLEYS AND ROADS FOR OTHER RESIDENTIAL USES.

THE FINAL SITE PLAN/BUILDING PERMIT SITE PLAN SHALL DEPICT A MINIMUM 5 FOOT CLEAR PATH OF TRAVEL FOR PEDESTRIAN WAYS, INCLUDING PUBLIC SIDEWALKS, AND THE LOCATION OF ALL EXISITNG AND PROPOSED OBSTRUCTIONS. PRIOR TO THE ISSUANCE OF USE AND OCCUPANCY PERMITS, EXISITNG OBSTRUCTIONS, INCLUDING POWER POLES AND SIGNAGE, WITHIN THE PATH OF TRAVEL SHALL BE RELOCATED TO PROVIDE A MINIMUM OF 5’ OF CLEAR ACCESS.

SIDEWALKS ALONG TRINITY LANE AND OLD MATHEWS ROAD SHALL BE PER MCSP. THE SIDEWALK ALONG TONEY ROAD SHALL BE 5’ IN WIDTH MEETING THE PUBLIC WORKS STANDARD ST-210, AND INCLUDE A 4’ PLANTING STRIP. THE CURB AND GUTTER ALONG TONEY ROAD TO MEET THE PUBLIC WORKS STANDARD ST-200.

STORMWATER/UTILITIES/INFRASTRUCTURE:STORMWATER PLANS FOR THIS DEVELOPMENT TO BE PROVIDED IN A MANNER CONSISTENT WITH THE STORMWATER VOLUME 5 LID MANUAL. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES TO INDICATE THE BASIC PREMISE OF THIS DEVELOPMENT AND PROPOSED STORMWATER LOCATIONS AND METHODS. FINAL DETIALS SHALL BE GOVERNED BY THE APPROPRIATE REGULATIONS AT THE TIEM OF THE SUBMITTAL.

SIZE DRIVEWAY CULVERTS PER THE DESIGN CRITERIA SET FORTH BY METRO STORMWATER MANAGEMENT MANUAL.

METRO WATER SERVICES SHALL BE PROVIDED SUFFICIENT AND UNENCUMBERED ACCESS IN ORDER TO MAINTAIN AND REPAIR UTILITIES ON THE SITE.

ALL WATER AND SEWER CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE SPECIFICAITONS ANDSTNDARD DETAILS OF METRO WATER SERVICES.

ALL ABOVE GROUND UTILITY BOXES/DEVICES WILL BE SCREENED APPROPRIATELY.

ALL PROPOSED NEW PUBLIC UTILITIES AND SERVICES SHALL BE INSTALLED UNDERGROUND.

ALL ACCESS DRIVES AND DRIVEWAYS WITHIN THIS DEVELOPMENT, WITH THE EXCEPTION OF TONEY ROAD, SHALL BE PRIVATE.

ALL PRIVATE DRIVES/ALLEYS MAY BE PAVED WITH PERVIOUS PAVEMENT WITH MATERIAL AND CROSS-SECTION TO BE APPROVED BY METRO PUBLIC WORKS. NO FRONT-LOADED GARAGES ARE PERMITTED ON A PUBLIC ROAD.

ALL SIDEWALKS LOCATED WITHIN THE PUBLIC R.O.W. ARE TO MEET METRO PUBLIC WORKS AND ADA STANDARDS.

BUFFER FOR ON SITE STREAMS INDICATED IN ACCORDANCE WITH AQUATIC RESOURCE ASSESSMENT PERFORMED BY BDY DATED MARCH, 23, 2016. NO DEFINED TOP OF BANK WAS INDICATED FOR THS STREAM SECTION.

REFER TO CIVIL DRAWINGS FOR ALL OTHER UTILITIES/ EASEMENTS.

SITE

W. TRINITY LN

WH

ITES C

REEK P

IKE

VICINITY MAP

SP CASE NO.: 2016SP-043-001

5

4

0

5

4

5

5

4

5

5

4

0

5

4

5

5

4

5

5

4

5

5

5

0

5

4

0

540

5

3

5

5

4

0

5

3

0

5

2

5

5

4

0

550

555

5

6

0

565

5

6

0

5

6

5

5

6

0

565

5

6

0

5

5

5

5

5

5

5

6

5

5

5

0

5

4

5

5

4

5

5

5

0

5

5

0

5

4

0

5

3

0

530

5

3

0

5

3

0

5

3

5

5

4

0

5

3

5

5

3

5

5

3

5

5

4

0

5

4

5

5

4

0

5

4

5

5

5

0

555

5

3

0

5

4

0

5

4

5

5

5

0

5

5

5

5

5

5

550

S

T

ST

ST

S

T

S

T

S

T

S

T

S

T

STS

T

S

T

S

T

ST

ST

ST

S

T

S

T

S

T

S

T

S

T

S

T

ST

ST

S

T

S

T

S

T

ST

S

T

S

T

S

T

S

T

540

545

545

5

4

5

100'

BE

NC

HM

AR

K - E

LE

V.=

54

1.7

6'

BE

NC

HM

AR

K - E

LE

V.=

54

6.6

3'

BE

NC

HM

AR

K - E

LE

V.=

54

6.7

5'

5

2

5

5

3

0

5

3

5

540

545

5

5

0

5

5

5

560

5

6

5

570

5

7

0

565

5

6

0

555

550

5

4

5

5

5

0

5

5

0

5

2

5

5

3

0

5

3

5

5

4

0

5

4

5

5

4

5

5

4

0

5

5

5

5

6

0

565

570

575

5

6

5

5

7

0

5

6

0

555

5

4

5

520

5

2

0

5

2

5

5

3

0

5

3

5

5

4

0

545

550

555

5

6

0

565

5

2

5

5

3

0

5

3

5

5

4

0

5

4

5

5

5

0

5

5

5

5

6

0

SE

AN K . DECOSTER

NO . 0 0 1 0 6 2 5 0STATE OF T ENNE S SEE

REG I STERED ENG INEER

CO

M M E R CE

05/17/16

JOB NO.: 15-742DATE: 4-28-16

5-17-16

SHEET:

TRIN

ITY

LA

NE

MA

STER

PLA

NN

ASH

VIL

LE, T

ENN

ESSE

E

DETAILS 01

L3.00

??%

CO

NST

RU

CTI

ON

DO

CU

MEN

TS

PREL

IMIN

AR

Y S

P

MAP 71-01 PARCELS

PROJECT BENCHMARK:

DESCRIPTION: MAG NAIL FLUSH

IN CONCRETE

ELEVATION: 541.76' (NAVD88)

17, 18, 19

20 & 21

CSDG PROJECT # : 15-098-02

0 5040302010 100 150

GRAPHIC SCALE 1"=50'

H

T

R

O

N C3.00GRADING AND

DRAINAGE PLAN

NOTES:1. MINOR MODIFICATIONS TO THE PRELIMINARY SP PLAN MAY BE APPROVED BY THE PLANNING COMMISSION OR ITS DESIGNEE BASED

UPON FINAL ARCHITECTURAL, ENGINEERING OR SITE DESIGN AND ACTUAL SITE CONDITIONS. ALL MODIFICATIONS SHALL BE CONSISTENTWITH THE PRINCIPLES AND FURTHER THE OBJECTIVES OF THE APPROVED PLAN. MODIFICATIONS SHALL NOT BE PERMITTED, EXCEPTTHROUGH AN ORDINANCE APPROVED BY METRO COUNCIL THAT INCREASE THE PERMITTED DENSITY OR FLOOR AREA, ADD USES NOTOTHERWISE PERMITTED, ELIMINATE SPECIFIC CONDITIONS OR REQUIREMENTS CONTAINED IN THE PLAN AS ADOPTED THROUGH THISENACTING ORDINANCE, OR ADD VEHICULAR ACCESS POINTS NOT CURRENTLY PRESENT OR APPROVED

2. THE REQUIRED FIRE FLOW SHALL BE DETERMINED BY THE METRO/NASHVILLE FIRE MARSHAL'S OFFICE PRIOR TO THE ISSUANCE OF ABUILDING PERMIT.

3. APPROVAL OF ANY SPECIFIC PLAN DOES NOT EXEMPT ANY PARCEL SHOWN ON THE PLAN OR ANY DEVELOPMENT WITHIN THE SP FROMCOMPLIANCE WITH ALL PROVISIONS OF THE METRO ZONING CODE WITH RESPECT TO FLOODPLAIN, STEEP SLOPES, UNSTABLE SOILS,SINKHOLES, ROCK OUTCROPPINGS, STREAMS, SPRINGS AND CRITICAL LOTS.

4. ANY EXCAVATION, FILL OR DISTURBANCE OF THE EXISTING GROUND MUST BE DONE IN ACCORDANCE WITH STORMWATERMANAGEMENT ORDINANCE 78-840 AND APPROVED BY THE METRO DEPARTMENT OF WATER SERVICES.

5. INDIVIDUAL WATER AND SEWER SERVICE LINES ARE REQUIRED FOR EACH UNIT.6. THE DEVELOPER OF THIS PROJECT SHALL COMPLY WITH THE REQUIREMENTS OF THE SP ADOPTED TREE ORDINANCE 2008-328 (METRO

CODE CHAPTER 17.24)7. ALL SURFACE PARKING AREAS MUST MEET THE "PARKING AREA SCREENING AND LANDSCAPING" REQUIREMENTS SPECIFIED IN THE

METRO ZONING CODE.8. ACCORDING TO FEMA'S CURRENT FLOOD MAPS (47037C0208F, DATED APRIL 20, 2001), AS WELL AS METRO'S GIS INFORMATION, THERE IS

NO 100-YEAR FLOODPLAIN WITHIN THE SP BOUNDARY.9. ACCORDING TO THE NRCS SOILS MAP, THE SOILS ON THE PROPERTY ARE BbD (BARFILED-ROCK OUTCROP), MmD (MIMOSA SILT LOAM),

MsD (MIMOSA-URBAN LAND COMPLEX). THESE SOILS ARE NOT “PROBLEM SOILS” AS NOTED IN SECTION 17.28.050 OF THE METROZONING CODE.

11. THERE ARE 2.13 ACRES OF THE SITE THAT HAVE EXISTING SLOPES FROM 15% TO 25% AND 0.39 ACRES THAT HAVE EXISTING SLOPESABOVE 25%.

12. TONEY ROAD SHALL BE PUBLIC RIGHT OF WAY. ALL OTHER ACCESS DRIVES AND DRIVEWAYS SHALL BE PRIVATE STREETS WITH PUBLICACCESS EASEMENTS.

13. THERE ARE NO KNOWN EXISTING WETLANDS WITHIN THE SP BOUNDARY.14. SIGNAGE SHALL MEET METRO DESIGN STANDARDS. A DETAILED SIGNAGE PLAN WILL BE SUBMITTED WITH THE FINAL SP DOCUMENTS, IF

REQUIRED.15. ALL DEVELOPMENT WITHIN THE BOUNDARIES OF THIS PLAN WILL BE DESIGNED BASED ON THE REQUIREMENTS OF THE AMERICANS WITH

DISABILITIES ACT AND THE FAIR HOUSING ACT.16. THE REQUIREMENTS OF THE METRO FIRE MARSHAL'S OFFICE FOR EMERGENCY VEHICLE ACCESS AND ADEQUATE WATER SUPPLY FOR FIRE

PROTECTION MUST BE MET PRIOR TO THE ISSUANCE OF ANY BUILDING PERMITS.17. ALL PROPOSED PUBLIC UTILITIES AND SERVICES SHALL BE INSTALLED UNDERGROUND.18. METRO WATER SERVICES SHALL BE PROVIDED SUFFICIENT AND UNENCUMBERED ACCESS IN ORDER TO MAINTAIN AND REPAIR UTILITIES

IN THIS SITE.19. SIZE DRIVEWAY CULVERTS PER THE DESIGN CRITERIA SET FORTH BY THE METRO STORMWATER MANAGEMENT MANUAL (MINIMUM

DRIVEWAY CULVERT IN METRO ROW IS 15" CMP).20. BUFFER FOR ON SITE STREAMS INDICATED IN ACCORDANCE WITH AQUATIC RESOURCE ASSESSMENT PERFORMED BY BDY ON MARCH 23,

2016. COPIES OF THIS STUDY AVAILABLE UPON REQUEST.21. BUFFERS SHOWN SHALL BE AN AREA WHERE THE SURFACE IS LEFT IN A NATURAL STATE AND NOT DISTURBED BY CONSTRUCTION

ACTIVITY. THIS IS IN ACCORDANCE WITH THE REGULATIONS IN THE STORMWATER MANAGEMENT MANUAL VOLUME 1.

BIORETENTION

BIORETENTION

HEADWALL

(TYP)

CURB INLET

(TYP)

STORM

MANHOLE

(TYP)

CATCH

BASIN

(TYP)

RETAINING

WALL

(TYP)

30' STREAM

BUFFER

PUBLIC UTILITY AND

DRAINAGE EASEMENT (TYP)

BIORETENTION

BIORETENTION

B

I

O

R

E

T

E

N

T

I

O

N

B

IO

R

E

T

E

N

T

IO

N

BIORETENTION

interng5
Typewritten Text
SP CASE NO.: 2016SP-043-001

W

W

W

W

W

W

W

W

W

W

SA

SA

SA

SA

SA

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

S

A

S

A

S

A

S

A

S

A

S

A

W

S

A

SA

W

S

A

W

W

W

W

W

W

W

W

W

W

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

T

ST

ST

S

T

S

T

S

T

S

T

S

T

STS

T

S

T

S

T

ST

ST

ST

S

T

S

T

S

T

S

T

S

T

S

T

ST

ST

S

T

S

T

S

T

ST

S

T

S

T

S

T

S

T

O

H

E

O

H

E

O

H

E

O

H

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

O

H

E

O

H

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

OH

E

O

H

E

O

H

E

O

H

E

O

H

E

O

H

E

O

H

E

G

G

G

G

G

G

G

O

H

E

O

H

E

O

H

E

OH

E

OH

E

O

H

E

O

H

E

O

H

E

O

H

E

O

H

E

OHE

O

H

E

O

H

E

O

H

E

O

H

E

O

H

E

OHE

O

H

E

O

H

E

O

H

E

O

H

E

O

H

E

O

H

E

O

H

E

W

W

W

W

W

W

W

W

W W W

W

W

W

W

W

W

W

O

H

E

O

H

E

O

H

E

O

HE

OH

E

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

O

H

E

OHE

O

H

E

O

H

E

O

H

E

O

H

E

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

SA

SA

SA

SA

SA

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

S

A

100'

O

H

E

O

H

E

BE

NC

HM

AR

K - E

LE

V.=

54

1.7

6'

BE

NC

HM

AR

K - E

LE

V.=

54

6.6

3'

BE

NC

HM

AR

K - E

LE

V.=

54

6.7

5'

2

0

'

20'

SE

AN K . DECOSTER

NO . 0 0 1 0 6 2 5 0STATE OF T ENNE S SEE

REG I STERED ENG INEER

CO

M M E R CE

05/17/16

JOB NO.: 15-742DATE: 4-28-16

5-17-16

SHEET:

TRIN

ITY

LA

NE

MA

STER

PLA

NN

ASH

VIL

LE, T

ENN

ESSE

E

DETAILS 01

L3.00

??%

CO

NST

RU

CTI

ON

DO

CU

MEN

TS

PREL

IMIN

AR

Y S

P

MAP 71-01 PARCELS

PROJECT BENCHMARK:

DESCRIPTION: MAG NAIL FLUSH

IN CONCRETE

ELEVATION: 541.76' (NAVD88)

17, 18, 19

20 & 21

CSDG PROJECT # : 15-098-02

0 5040302010 100 150

GRAPHIC SCALE 1"=50'

H

T

R

O

N C4.00SITE UTILITY PLAN

SANITARY

MANHOLE

(TYP)

1

0

' M

IN

.

S

E

P

A

R

A

T

IO

N

(T

Y

P

)

CONNECT TO

EX. WATERLINE

DOG HOUSE

MANHOLE

CONNECT TO

EX. WATERLINE

CONNECT TO

EX. WATERLINE

EX. UTILITY

EASEMENT

30' STREAM

BUFFER

30' STREAM

BUFFER

CONNECT TO

EX. MANHOLE

CONNECT TO

EX. WATERLINE

CONNECT TO

EX. MANHOLE

CONNECT TO

EX. MANHOLE

CONNECT TO

EX. MANHOLE

DOG HOUSE

MANHOLE

TVA EASEMENT

NOTES:1. MINOR MODIFICATIONS TO THE PRELIMINARY SP PLAN MAY BE APPROVED BY THE PLANNING COMMISSION OR ITS DESIGNEE BASED

UPON FINAL ARCHITECTURAL, ENGINEERING OR SITE DESIGN AND ACTUAL SITE CONDITIONS. ALL MODIFICATIONS SHALL BE CONSISTENTWITH THE PRINCIPLES AND FURTHER THE OBJECTIVES OF THE APPROVED PLAN. MODIFICATIONS SHALL NOT BE PERMITTED, EXCEPTTHROUGH AN ORDINANCE APPROVED BY METRO COUNCIL THAT INCREASE THE PERMITTED DENSITY OR FLOOR AREA, ADD USES NOTOTHERWISE PERMITTED, ELIMINATE SPECIFIC CONDITIONS OR REQUIREMENTS CONTAINED IN THE PLAN AS ADOPTED THROUGH THISENACTING ORDINANCE, OR ADD VEHICULAR ACCESS POINTS NOT CURRENTLY PRESENT OR APPROVED

2. THE REQUIRED FIRE FLOW SHALL BE DETERMINED BY THE METRO/NASHVILLE FIRE MARSHAL'S OFFICE PRIOR TO THE ISSUANCE OF ABUILDING PERMIT.

3. APPROVAL OF ANY SPECIFIC PLAN DOES NOT EXEMPT ANY PARCEL SHOWN ON THE PLAN OR ANY DEVELOPMENT WITHIN THE SP FROMCOMPLIANCE WITH ALL PROVISIONS OF THE METRO ZONING CODE WITH RESPECT TO FLOODPLAIN, STEEP SLOPES, UNSTABLE SOILS,SINKHOLES, ROCK OUTCROPPINGS, STREAMS, SPRINGS AND CRITICAL LOTS.

4. ANY EXCAVATION, FILL OR DISTURBANCE OF THE EXISTING GROUND MUST BE DONE IN ACCORDANCE WITH STORMWATERMANAGEMENT ORDINANCE 78-840 AND APPROVED BY THE METRO DEPARTMENT OF WATER SERVICES.

5. INDIVIDUAL WATER AND SEWER SERVICE LINES ARE REQUIRED FOR EACH UNIT.6. THE DEVELOPER OF THIS PROJECT SHALL COMPLY WITH THE REQUIREMENTS OF THE SP ADOPTED TREE ORDINANCE 2008-328 (METRO

CODE CHAPTER 17.24)7. ALL SURFACE PARKING AREAS MUST MEET THE "PARKING AREA SCREENING AND LANDSCAPING" REQUIREMENTS SPECIFIED IN THE

METRO ZONING CODE.8. ACCORDING TO FEMA'S CURRENT FLOOD MAPS (47037C0208F, DATED APRIL 20, 2001), AS WELL AS METRO'S GIS INFORMATION, THERE IS

NO 100-YEAR FLOODPLAIN WITHIN THE SP BOUNDARY.9. ACCORDING TO THE NRCS SOILS MAP, THE SOILS ON THE PROPERTY ARE BbD (BARFILED-ROCK OUTCROP), MmD (MIMOSA SILT LOAM),

MsD (MIMOSA-URBAN LAND COMPLEX). THESE SOILS ARE NOT “PROBLEM SOILS” AS NOTED IN SECTION 17.28.050 OF THE METROZONING CODE.

11. THERE ARE 2.13 ACRES OF THE SITE THAT HAVE EXISTING SLOPES FROM 15% TO 25% AND 0.39 ACRES THAT HAVE EXISTING SLOPESABOVE 25%.

12. TONEY ROAD SHALL BE PUBLIC RIGHT OF WAY. ALL OTHER ACCESS DRIVES AND DRIVEWAYS SHALL BE PRIVATE STREETS WITH PUBLICACCESS EASEMENTS.

13. THERE ARE NO KNOWN EXISTING WETLANDS WITHIN THE SP BOUNDARY.14. SIGNAGE SHALL MEET METRO DESIGN STANDARDS. A DETAILED SIGNAGE PLAN WILL BE SUBMITTED WITH THE FINAL SP DOCUMENTS, IF

REQUIRED.15. ALL DEVELOPMENT WITHIN THE BOUNDARIES OF THIS PLAN WILL BE DESIGNED BASED ON THE REQUIREMENTS OF THE AMERICANS WITH

DISABILITIES ACT AND THE FAIR HOUSING ACT.16. THE REQUIREMENTS OF THE METRO FIRE MARSHAL'S OFFICE FOR EMERGENCY VEHICLE ACCESS AND ADEQUATE WATER SUPPLY FOR FIRE

PROTECTION MUST BE MET PRIOR TO THE ISSUANCE OF ANY BUILDING PERMITS.17. ALL PROPOSED PUBLIC UTILITIES AND SERVICES SHALL BE INSTALLED UNDERGROUND.18. METRO WATER SERVICES SHALL BE PROVIDED SUFFICIENT AND UNENCUMBERED ACCESS IN ORDER TO MAINTAIN AND REPAIR UTILITIES

IN THIS SITE.19. SIZE DRIVEWAY CULVERTS PER THE DESIGN CRITERIA SET FORTH BY THE METRO STORMWATER MANAGEMENT MANUAL (MINIMUM

DRIVEWAY CULVERT IN METRO ROW IS 15" CMP).20. BUFFER FOR ON SITE STREAMS INDICATED IN ACCORDANCE WITH AQUATIC RESOURCE ASSESSMENT PERFORMED BY BDY ON MARCH 23,

2016. COPIES OF THIS STUDY AVAILABLE UPON REQUEST.21. BUFFERS SHOWN SHALL BE AN AREA WHERE THE SURFACE IS LEFT IN A NATURAL STATE AND NOT DISTURBED BY CONSTRUCTION

ACTIVITY. THIS IS IN ACCORDANCE WITH THE REGULATIONS IN THE STORMWATER MANAGEMENT MANUAL VOLUME 1.

BIORETENTION

BIORETENTION

BIORETENTION

BIORETENTION

B

I

O

R

E

T

E

N

T

I

O

N

B

IO

R

E

T

E

N

T

IO

N

BIORETENTION

PUBLIC UTILITY &

DRAINAGE EASEMENT

interng5
Typewritten Text
SP CASE NO.: 2016SP-043-001