schematic design pricing set a100 · 2019. 8. 7. · retail addition/renovation for restaurant 924...
TRANSCRIPT
EX. TOILET
EX. TOILET
RETAILAREA
STAIR
VEST.
INVENTORY
VERIFY THAT EXTERIOR CAN BE MOVED IN FRAME. IF NOT, DEMO AND SALVAGE ENTIRE ASSEMBLY FOR REUSE.
DEMO FOR NEW OPENING
EXISTING DECKING TO BE REMOVED WITHIN THE FENCELINE AND PREP AREA FOR NEW PAVERS
REMOVE CEILING AND FLOOR ABOVE FOR NEW COOLER
EXISITNG BEAM ABOVE
REMOVE AND SALVAGE DOORS FOR REUSE
REMOVE EXISITNG SWING DOORS AND OVERHEAD DOOR
REMOVE EXISTING CHAINLINK FENCE AND CONCRETE PAD.
PLAN FOR NEW OPENINGS
PLAN FOR NEW OPENINGS
PLAN FOR NEW OPENINGS
EXISTING CONCRETE SLAB TO BE REMOVED
EX
IST
ING
TR
EE
S T
O B
E R
EM
OV
ED
REMOVE EXISTING DOOR AND FRAME
EXISTING CONCRETE SLAB AND DECKING TO BE REMOVED AND PREPED FOR NEW PAVERS
EXISTING DECKING TO BE REMOVED
REMOVE EXISTING TRELLIS
REMOVE EXISTING WALL -SALVAGE DOOR FOR NEW LOCATION
1. Refer to Sheet A000 for general conditions and requirements for all construction.
2. contractor to perform the work outlined in these notes in all areas of construction unless noted otherwise in these documents:
3. refer to architectural plan, sheet a1.1 series, for dimensional extent of building elements to remain and to be removed.
4. remove and store existing doors as indicated for reuse. see construction plan sheet a1.1 for new locations.
5. where existing openings are to be infilled - remove existing h.m. frame, door and hardware and prepare opening for infilling with materials to match existing wall construction.
6. where new openings are planned - remove section of existing partition as indicated and prepare opening for installation of door / frame or cased opening as scheduled.
7. where new finishes are specified on the finish plan. remove all existing finishes -patch and repair walls and floor - prepare them to accept new scheduled finish per manufacturer's instructions.
GENERAL NOTES
DEMOLITION PLAN SYMBOLS
INDICATES AREAS TO BE REMOVED
Smith Gee Studio, LLC209 10th Avenue South, Suite 425
Nashville, Tennessee 37203phone: (615)739-5555
No: Date: Revision::
Pro
ject
Ad
dre
ss:
PR
ELIM
INA
RY
NO
T F
OR
CO
NSTR
UC
TIO
N
Copyright 2018 by Smith Gee Studio, LLC: All drawings and text contained in these drawings are the property of Smith Gee
Studio, LLC and cannot be used without the express written permission. Do not scale drawings, if dimensions are needed
but not shown consult architect.
No
tes:
Drawing:
9/2
0/2
018 5
:12:1
4 P
M
92
4 8
th A
ve S
, N
ash
vil
le,
TN
37
20
3
Re
tail
Ad
dit
ion
/Re
no
vati
on
fo
r R
esta
ura
nt
Clie
nt
Conta
ct
: E
mily
Layne
Thom
pson
SG
S P
roje
ct
Num
ber:
18047.0
0
Re
tail A
dd
itio
n/R
en
ov
ati
on
fo
rR
es
tau
ran
t
DEMO PLAN
A100
(615)
214-5
465
SG
S C
onta
ct
:Dalla
s C
audle
Schematic Design Pricing Set
Issue Date - 9/20/2018
1/4" = 1'-0"1
1ST FLOOR DEMO
UP
DN
A300
3
A300
2
A3
00
1
A220
2
AL-1
103
108107
104 EX01
105
106
111
EX07
EX06
EX05
110
EX04
EX03
109
EX08
A400
A101a
1
BUILT IN BENCHESSTAIN GRADE WITH LOW BACK AND PLENTH BASE BELOW
UNISTRUT FOR DECORATIVE STRING LIGHTS AND DECOR
UNISTRUT FOR DECORATIVE STRING LIGHTS AND DECOR
RETAIL SHELVING BY OWERNER (TYP).
RETAIL COUNTER SOLIDSURFACE AND KNEE WALLBELOW
BAR WITH QUARTZSURFACE COUNTER ANDKNEE WALL BELOW
Built in Shelving, Fixed Shelves, Stain Grade
Built in Shelving, Fixed Shelves, Stain Grade
PANTRY
COOLER
WASH
JAN.CLOS.
PREPKITCHEN
VEST.
OFFICE
INVENTORY
EX. TOILET
EX. TOILET
NEWTOILET
STORAGE
716 SFSOLARIUM
FILL IN EXISTING DOORS AND WINDOW. APPLY SHIP LAP SIDING (TYP.) TO DECK. SIDING TO BE PAINTED.
OPENNING FOR PASS THROUGH WITH STAINLESS STEEL TOP
LAMINATE COUNTER TOP WITH EQUIPMENT BELOW
WALK IN COOLER/ REF. TO BE BUILT IN PLACE AND PASS THROUGH UP AREA.
4' -
0"
114
BB
AA A
G
AL-2
A
AL-4
24' - 0"
5' -
4 1
/2"
2' -
5 5
/8"
12' -
2"
2' -
0"
12' -
2"
13' -
9 7
/8"
NEW FENCE AND GATE
EQ
EQ
60"
56"
JAN.
30' -
4 1
/4"
NEW SKYLIGHTS ABOVE
6' - 1" 10' - 6 7/8"
EQ EQ
9' - 5"
12' -
0 7
/8"
3' -
0"
6' - 5"
8' -
0 1
/8"
27' - 1 1/4"
LOADING DOCK
3' - 6" 20' - 6"
11' -
9 3
/4"
1' - 6 3/8"
17' - 0" 3' - 0 1/8"
10' -
5 1
/4"
10' -
5 1
/4"
10' -
5 1
/4"
1' -
0 5
/8"
EQ
EQ
EQ
EQ
EQ
EQ
EQ
5
1. ALL EXTERIOR DIMENSIONS ARE SHOWN FACE OF STUD, FACE OF CMU, OR FACE OF CONCRETE UNLESS NOTED OTHERWISE.
2. ALL INTERIOR DIMENSIONS ARE SHOWN TO FACE OF STUD, FACE OF CMU, OR FACE OF CONCRETE UNLESS NOTED OTHERWISE.
3. ELEVATIONS SHOWN IN ARCHITECTURAL ARE RELATIVE TO MEAN SEA LEVEL ELEVATION 0'-0". ACTUAL BUILDING ELEVATION ABOVE MEAN SEA LEVEL VARIES - REFER TO CIVIL DRAWINGS FOR ACTUAL BUILDING ELEVATION LEVELS, TYP.
4. REFER TO STRUCTURAL SLAB / FOUNDATION PLAN FOR CLARIFICATION OF SLAB, SLAB LEAVE-OUT AND CURB DIMENSIONS.
5. SEE SHEETS A200-A205 FOR EXTERIOR & INTERIOR WALL TYPES AND UL ASSEMBLIES.
6. ORIENTATION OF THE BUILDING PLAN ILLUSTRATED MAY BE DIFFERENT THAN THE ORIENTATION OF THE CONSULTANT PLANS. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
7. ALL MECHANICAL, ELECTRICAL, PLUMBING, SECURITY, UTILITY, CABLE TV, AND TELEPHONE EQUIPMENT SHALL BE INSTALLED SO AS NOT TO BE IN CONFLICT WITH ANY WINDOW OR DOOR, TYP.
8. PROVIDE POSITIVE DRAINAGE AWAY FROM THE BUILDING. PROVIDE POSITIVE DRAINAGE AWAY FROM EXTERIOR DOORS AND STOREFRONTS.
9. SEE SHEET A210-A223 FOR DOOR AND WINDOW SCHEDULE AND DETAIL INFORMATION.
10. ALL INTERIOR PARTITIONS SHALL EXTEND TO AND BE SEALED AGAINST THE FLOOR/ROOF DECK ABOVE.
11. PROVIDE AIR TIGHT CONSTRUCTION SEAL AROUND ALL PENETRATIONS (I.E., BEAM, CONDUIT, ETC.) THROUGH RATED WALLS.
12. SEE ENLARGED STAIR AND ELEVATOR PLANS FOR FIRE RATINGS.
PLAN NOTES
OVERALL PLAN LEGEND
XXX
UNIT TYPE
ADDRESS NUMBER
1/4" = 1'-0"1
1ST FLOOR
Smith Gee Studio, LLC209 10th Avenue South, Suite 425
Nashville, Tennessee 37203phone: (615)739-5555
No: Date: Revision::
Pro
ject
Ad
dre
ss:
PR
ELIM
INA
RY
NO
T F
OR
CO
NSTR
UC
TIO
N
Copyright 2018 by Smith Gee Studio, LLC: All drawings and text contained in these drawings are the property of Smith Gee
Studio, LLC and cannot be used without the express written permission. Do not scale drawings, if dimensions are needed
but not shown consult architect.
No
tes:
Drawing:
9/2
0/2
018 5
:12:1
6 P
M
92
4 8
th A
ve S
, N
ash
vil
le,
TN
37
20
3
Re
tail
Ad
dit
ion
/Re
no
vati
on
fo
r R
esta
ura
nt
Clie
nt
Conta
ct
: E
mily
Layne
Thom
pson
SG
S P
roje
ct
Num
ber:
18047.0
0
Re
tail A
dd
itio
n/R
en
ov
ati
on
fo
rR
es
tau
ran
t
FIRST FLOOR PLAN
A101
(615)
214-5
465
SG
S C
onta
ct
:Dalla
s C
audle
Schematic Design Pricing Set
Issue Date - 9/20/2018
ENLARGED PLAN LEGEND
DOOR NUMBER - REFER TO SHEET A220 FOR DOOR SCHEDULE
WINDOW NUMBER - REFER TO SHEET A230 FOR WINDOW SCHEDULE
STOREFRONT NUMBER - REFER TOSHEETS A240-A241 FOR TYPES
WALL TYPE - REFER TO SHEETS A200
UNIT TYPE
SHEET NUMBER
DETAIL NUMBER
XXX
3-HOUR RATED WALL
2-HOUR RATED WALL
4-HOUR RATED WALL
XXX
ROOM NAME
ROOM NUMBER
1t
1i
1i
1. ALL EXTERIOR DIMENSIONS ARE SHOWN FACE OF STUD, FACE OF CMU, OR FACE OF CONCRETE UNLESS NOTED OTHERWISE.
2. ALL INTERIOR DIMENSIONS ARE SHOWN TO FACE OF STUD, FACE OF CMU, OR FACE OF CONCRETE UNLESS NOTED OTHERWISE.
3. ELEVATIONS SHOWN IN ARCHITECTURAL ARE RELATIVE TO MEAN SEA LEVEL ELEVATION 0'-0". ACTUAL BUILDING ELEVATION ABOVE MEAN SEA LEVEL VARIES - REFER TO CIVIL DRAWINGS FOR ACTUAL BUILDING ELEVATION LEVELS, TYP.
4. REFER TO STRUCTURAL SLAB / FOUNDATION PLAN FOR CLARIFICATION OF SLAB, SLAB LEAVE-OUT AND CURB DIMENSIONS.
5. SEE SHEETS A200-A205 FOR EXTERIOR & INTERIOR WALL TYPES AND UL ASSEMBLIES.
6. ORIENTATION OF THE BUILDING PLAN ILLUSTRATED MAY BE DIFFERENT THAN THE ORIENTATION OF THE CONSULTANT PLANS. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
7. ALL MECHANICAL, ELECTRICAL, PLUMBING, SECURITY, UTILITY, CABLE TV, AND TELEPHONE EQUIPMENT SHALL BE INSTALLED SO AS NOT TO BE IN CONFLICT WITH ANY WINDOW OR DOOR, TYP.
8. PROVIDE POSITIVE DRAINAGE AWAY FROM THE BUILDING. PROVIDE POSITIVE DRAINAGE AWAY FROM EXTERIOR DOORS AND STOREFRONTS.
9. SEE SHEET A210-A223 FOR DOOR AND WINDOW SCHEDULE AND DETAIL INFORMATION.
10. ALL INTERIOR PARTITIONS SHALL EXTEND TO AND BE SEALED AGAINST THE FLOOR/ROOF DECK ABOVE.
11. PROVIDE AIR TIGHT CONSTRUCTION SEAL AROUND ALL PENETRATIONS (I.E., BEAM, CONDUIT, ETC.) THROUGH RATED WALLS.
12. SEE ENLARGED STAIR AND ELEVATOR PLANS FOR FIRE RATINGS.
PLAN NOTES
A220
1
COUNTERSERVICE
WASH
JAN.
PREPKITCHEN
PANTRY
COOLERRETAILAREA
A220
4
ATTIC
Cooler Below is Higher than Existing Attic Floor. Floor and Bracing will need to be modified to accomodate
4 Ton AC unit will need to be located up here.
Smith Gee Studio, LLC209 10th Avenue South, Suite 425
Nashville, Tennessee 37203phone: (615)739-5555
No: Date: Revision::
Pro
ject
Ad
dre
ss:
PR
ELIM
INA
RY
NO
T F
OR
CO
NSTR
UC
TIO
N
Copyright 2018 by Smith Gee Studio, LLC: All drawings and text contained in these drawings are the property of Smith Gee
Studio, LLC and cannot be used without the express written permission. Do not scale drawings, if dimensions are needed
but not shown consult architect.
No
tes:
Drawing:
9/2
0/2
018 5
:12:1
7 P
M
92
4 8
th A
ve S
, N
ash
vil
le,
TN
37
20
3
Re
tail
Ad
dit
ion
/Re
no
vati
on
fo
r R
esta
ura
nt
Clie
nt
Conta
ct
: E
mily
Layne
Thom
pson
SG
S P
roje
ct
Num
ber:
18047.0
0
Re
tail A
dd
itio
n/R
en
ov
ati
on
fo
rR
es
tau
ran
t
ENLARGED FIRSTFLOOR
A101a
(615)
214-5
465
SG
S C
onta
ct
:Dalla
s C
audle
Schematic Design Pricing Set
Issue Date - 9/20/2018
1/4" = 1'-0"1
ENLARGED KITCHEN PLAN 1/4" = 1'-0"
2ATTIC- ENLARGE PLAN
DN
A300
3
A3
00
2
New Bubble Skylights, 4' x 4' shown in at New Addition
New Roof and skylights to be to be provided by owner. This should be completed prior to Phase 1 Construction starting. Provide allowance for plumbing stub ups and vendting that will need to added to roof with construction and for modifications related to HVAC
New Roof to be in Phase 1
9' -
6 1
/2"
7' - 9 7/8" 10' - 9 1/8" 6' - 9 3/4"
5
Smith Gee Studio, LLC209 10th Avenue South, Suite 425
Nashville, Tennessee 37203phone: (615)739-5555
No: Date: Revision::
Pro
ject
Ad
dre
ss:
PR
ELIM
INA
RY
NO
T F
OR
CO
NSTR
UC
TIO
N
Copyright 2018 by Smith Gee Studio, LLC: All drawings and text contained in these drawings are the property of Smith Gee
Studio, LLC and cannot be used without the express written permission. Do not scale drawings, if dimensions are needed
but not shown consult architect.
No
tes:
Drawing:
9/2
0/2
018 5
:12:1
7 P
M
92
4 8
th A
ve S
, N
ash
vil
le,
TN
37
20
3
Re
tail
Ad
dit
ion
/Re
no
vati
on
fo
r R
esta
ura
nt
Clie
nt
Conta
ct
: E
mily
Layne
Thom
pson
SG
S P
roje
ct
Num
ber:
18047.0
0
Re
tail A
dd
itio
n/R
en
ov
ati
on
fo
rR
es
tau
ran
t
ROOF PLAN
A105
(615)
214-5
465
SG
S C
onta
ct
:Dalla
s C
audle
Schematic Design Pricing Set
Issue Date - 9/20/2018
1/4" = 1'-0"1
Enlarged - Roof
HOLLOW METAL DOOR
COMMON AREA DOOR ELEVATIONS
TYPE A TYPE B TYPE C TYPE D TYPE E
TYPE G
ALL EXISTING DOORS
FULL GLASS WOOD DOOR
NARROW VIEW DOUBLE DOOR
ALUMINUM STOREFRONT
GARAGE DOOR
TYPE FALUMINUM
STOREFRONT
CTCT CTCT
HOLLOW METAL FRAME
FRAME TYPES
TYPE HM-1 TYPE HM- 4DOUBLE-SWING
FIRE DOOR
NOTE:1. CT - Clear Tempered2. See building plans for door swing direction3. Refer to elevations for exterior finish at door trim (i.e. brick, metal, siding)
HARDWARE SET 01ashfjskafdsakjfhkasdfasdhfkasdjjfhsdfasdahfsdafjsaasdfjsafl
HARDWARE SETS
9' - 4"
3' - 3 3/4" 2' - 11 1/2" 3' - 0 3/4"
8' -
0"
1' -
0"
7' -
0"
EXTERIORALUMINUM STOREFRONT
TYPE AL-1SEE DOOR SCHEDULE
9' - 0"
3' - 0" 3' - 0" 3' - 0"
8' -
0"
6' -
8"
1' -
4"
EXTERIORALUMINUM STOREFRONT
TYPE AL-2
SEE DOOR SCHEDULE
EXTERIORALUMINUM STOREFRONT
TYPE AL-3
5' - 2"
1' - 11 1/2" 3' - 0" 2 1/2"
8' -
0"
7' -
0"
1' -
0"
EXTERIORALUMINUM STOREFRONT
TYPE AL-4
SEE DOOR SCHEDULE
WINDOW Match Existing Exterior
WINDOW TYPES
TYPE AWINDOW
Match Existing
TYPE B1' -
3 3
/4"
2' -
6"
4' -
10 1
/4"
Smith Gee Studio, LLC209 10th Avenue South, Suite 425
Nashville, Tennessee 37203phone: (615)739-5555
No: Date: Revision::
Pro
ject
Ad
dre
ss:
PR
ELIM
INA
RY
NO
T F
OR
CO
NSTR
UC
TIO
N
Copyright 2018 by Smith Gee Studio, LLC: All drawings and text contained in these drawings are the property of Smith Gee
Studio, LLC and cannot be used without the express written permission. Do not scale drawings, if dimensions are needed
but not shown consult architect.
No
tes:
Drawing:
9/2
0/2
018 5
:12:1
9 P
M
92
4 8
th A
ve S
, N
ash
vil
le,
TN
37
20
3
Re
tail
Ad
dit
ion
/Re
no
vati
on
fo
r R
esta
ura
nt
Clie
nt
Conta
ct
: E
mily
Layne
Thom
pson
SG
S P
roje
ct
Num
ber:
18047.0
0
Re
tail A
dd
itio
n/R
en
ov
ati
on
fo
rR
es
tau
ran
t
DOOR, WINDOW, ANDSTOREFRONT TYPES &SCHEDULE
A220
(615)
214-5
465
SG
S C
onta
ct
:Dalla
s C
audle
Schematic Design Pricing Set
Issue Date - 9/20/2018
COMMON AREAS DOOR SCHEDULE
MARK WIDTH HEIGHT THICK
DOOR FRAME HARDWARESET REMARKSMATERIAL FINISH TYPE RATING GLAZING TYPE MATERIAL HEAD JAMB THRESHOLD
103 3' - 0" 6' - 8" 1 3/4" ALUMINUM / WOOD E Yes
104 3' - 0" 7' - 0" 1 3/4" ALUMINUM C Yes
105 3' - 0" 7' - 0" 1 3/4" ALUMINUM / WOOD E Yes
106 3' - 0" 7' - 0" 1 3/4" ALUMINUM / WOOD E Yes
107 3' - 0" 7' - 0" 0" ALUMINUM / WOOD B No
108 3' - 0" 7' - 0" 0" ALUMINUM / WOOD B No
109 3' - 0" 6' - 8" 1 3/4" HOLLOW METAL A No
110 2' - 6" 6' - 8" 1 3/4" HOLLOW METAL A No
111 2' - 6" 6' - 8" 1 3/4" HOLLOW METAL A No
114 3' - 0" 7' - 0" 1 3/4" WOOD B
115 6' - 0" 7' - 0" 1 3/4" HOLLOW METAL D No
116 6' - 0" 7' - 0" 1 3/4" HOLLOW METAL D No
117 3' - 0" 7' - 0" 1 3/4" WOOD B
118 3' - 0" 6' - 8" 1 3/4" HOLLOW METAL A No
119 3' - 0" 7' - 0" 1 3/4" ALUMINUM C Yes
120 3' - 0" 7' - 0" 0" ALUMINUM / WOOD B No
555 11' - 8" 11' - 10" HOLLOW METAL H No
559 3' - 0" 6' - 8" 1 3/4" HOLLOW METAL A No
561 3' - 0" 6' - 8" 1 3/4" HOLLOW METAL A No
581 6' - 0" 7' - 0" 2" HOLLOW METAL H No
EX01 3' - 0" 7' - 0" 1 3/4" WOOD B
EX02 3' - 0" 7' - 0" 1 3/4" WOOD B
EX03 3' - 0" 6' - 8" 1 3/4" WOOD B
EX04 3' - 0" 6' - 8" 1 3/4" WOOD B
EX05 3' - 0" 6' - 8" 1 3/4" WOOD B
EX06 3' - 0" 6' - 8" 1 3/4" WOOD B
EX07 3' - 0" 6' - 8" 1 3/4" WOOD B
EX08 3' - 0" 6' - 8" 1 3/4" WOOD B
1ST FLOOR0"
ROOF13' - 4"
ATTIC9' - 0"
1
A4004
A400
3
A400
3' - 2 3/4" 5' - 10 1/2" 3' - 0 3/4"
12' - 2" typ
1ST FLOOR0"
ROOF13' - 4"
ATTIC9' - 0"
1
A4004
A400
3
A400
Existing Canopy
5' - 2"
8' -
0"
New Storefront Relocated Door or New Storefront
1ST FLOOR0"
ROOF13' - 4"
ATTIC9' - 0"
4
A300
2
A400
Add Window to Match Existing
PHASE 2
PHASE ONE24' - 1 1/4" 1' - 3 1/2"
New Door and Window System to Match Existing
18' - 6" vif
8' -
8"
vif
1
A400
3
A400
Smith Gee Studio, LLC209 10th Avenue South, Suite 425
Nashville, Tennessee 37203phone: (615)739-5555
No: Date: Revision::
Pro
ject
Ad
dre
ss:
PR
ELIM
INA
RY
NO
T F
OR
CO
NSTR
UC
TIO
N
Copyright 2018 by Smith Gee Studio, LLC: All drawings and text contained in these drawings are the property of Smith Gee
Studio, LLC and cannot be used without the express written permission. Do not scale drawings, if dimensions are needed
but not shown consult architect.
No
tes:
Drawing:
9/2
0/2
018 5
:12:2
0 P
M
92
4 8
th A
ve S
, N
ash
vil
le,
TN
37
20
3
Re
tail
Ad
dit
ion
/Re
no
vati
on
fo
r R
esta
ura
nt
Clie
nt
Conta
ct
: E
mily
Layne
Thom
pson
SG
S P
roje
ct
Num
ber:
18047.0
0
Re
tail A
dd
itio
n/R
en
ov
ati
on
fo
rR
es
tau
ran
t
EXTERIOR ELEVATIONS
A300
(615)
214-5
465
SG
S C
onta
ct
:Dalla
s C
audle
Schematic Design Pricing Set
Issue Date - 9/20/2018
ELEVATION NOTES
1/4" = 1'-0"1
EAST ELEVATION FROM ALLEY
1/4" = 1'-0"2
WEST ELEVATION
1/4" = 1'-0"3
SOUTH ELEVATION
1/4" = 1'-0"4
PATIO ELEVATION LOOKING WEST
New Bubble Skylights (see Roof Plan)
Existing
New Windows to Match Existing
Wood siding to match existing
New fence surround @ mechanical units chain link
New wood siding
New Garage Door
Loading Dock and Steps Down
NEW TRELLIS AND CANOPY STRUCTURE
NEW TRELLIS AND CANOPY STRUCTURE
1ST FLOOR0"
ROOF13' - 4"
ATTIC9' - 0"
Unistruts
1ST FLOOR0"
ROOF13' - 4"
ATTIC9' - 0"
1
A400
4
A400
3
A400
EX1
EX1
A
Wall to be clad in Paint Grade ShiplapBAR WITH QUARTZSURFACE COUNTER ANDKNEE WALL BELOW
Floating Shelves along wall (typ.)
Built in Shelving, Fixed Shelves, Stain Grade
Metal Rolling Ladder and Rail
1ST FLOOR0"
ROOF13' - 4"
ATTIC9' - 0"
EX1 EX1EX1 EX1EX1 EX1
RETAIL COUNTER SOLIDSURFACE AND KNEE WALLBELOW
BAR WITH QUARTZSURFACE COUNTER ANDKNEE WALL BELOW
1ST FLOOR0"
ROOF13' - 4"
ATTIC9' - 0"
Unistruts
Built in Shelving, Fixed Shelves, Stain Grade
19' - 0" 18' - 6"
Built in Shelving, Fixed Shelves, Stain Grade
9' -
5 7
/8"
1' -
7 1
/8"
4' -
2"
Smith Gee Studio, LLC209 10th Avenue South, Suite 425
Nashville, Tennessee 37203phone: (615)739-5555
No: Date: Revision::
Pro
ject
Ad
dre
ss:
PR
ELIM
INA
RY
NO
T F
OR
CO
NSTR
UC
TIO
N
Copyright 2018 by Smith Gee Studio, LLC: All drawings and text contained in these drawings are the property of Smith Gee
Studio, LLC and cannot be used without the express written permission. Do not scale drawings, if dimensions are needed
but not shown consult architect.
No
tes:
Drawing:
9/2
0/2
018 5
:12:2
3 P
M
92
4 8
th A
ve S
, N
ash
vil
le,
TN
37
20
3
Re
tail
Ad
dit
ion
/Re
no
vati
on
fo
r R
esta
ura
nt
Clie
nt
Conta
ct
: E
mily
Layne
Thom
pson
SG
S P
roje
ct
Num
ber:
18047.0
0
Re
tail A
dd
itio
n/R
en
ov
ati
on
fo
rR
es
tau
ran
t
OVERALL BUILDINGSECTIONS
A400
(615)
214-5
465
SG
S C
onta
ct
:Dalla
s C
audle
Schematic Design Pricing Set
Issue Date - 9/20/2018
1/4" = 1'-0"1
SECTION FACING SOUTH
1/4" = 1'-0"2
CROSS SECTION FACING WEST
1/4" = 1'-0"3
LONGITUDINAL SECTION FACING NORTH
1/4" = 1'-0"4
SECTION FACING NORTH
1/4" = 1'-0"5
INTERIOR SECTION AT NEW SOLARIUM
SD
INVENTORY
NEWTOILET
EX. TOILET
EX. TOILET
RETAILAREA
VEST.
STAIR
EX1
A
B
B
B
B
B B B
EX1EX1
C
C
CC
C
C
EX1EX1 EX1
EX1 EX1
TYP.
Gyp8' - 0"C
F
EXF
RF
B
Ex. GYP.8' - 0"
Ex. GYP.8' - 0"
Ex. GYP.8' - 0"
Ex. GYP.8' - 0"
Mechanical to be extended into Solarium
Patch to Match Ceiling
Patch to Match Ceiling
Patch to Match Ceiling
Remove Existing Ceiling for New Walkin Cooler. See Floor plan for
coordeination notes
Plan for New Paver Lights along the Exterior in line with the Planter Boxes
F
F
F
F
F
F
F
F
F
Light included in unit
Replace existing fixtures w/LED equivalent
EQ
EQ
EQ
REFLECTED CEILING PLAN SYMBOLS
DOWNLIGHT
CEILING MOUNTED FIXTURE
CEILING PENDANT
DECORATIVE EXTERIOR SCONCE
HORIZONTAL VANITY SCONCE
DECORATIVE WALL SCONCE
LIGHT TRACK AND HEADS
LINEAR PENDANT
1X4 CEILING MOUNTED FLUORESCENT FIXTURE
4'-0" WALL MOUNTED FLUORESCENT FIXTURE
SMOKE DETECTOR
RETURN AIR GRILL
SUPPLY AIR GRILL
COMBINATION LIGHT EXHAUST FAN
STANDARD CEILING, HEIGHT VARIES
UNIT RCP - FURRED DOWN GYP. CEILING @ 8'-0" A.F.F.
REFER TO GENERAL NOTES SHEET AG02 FOR GENERAL CONDITIONS AND REQUIREMENTS FOR ALL CONSTRUCTION.
1. CONTRACTOR TO PERFORM THE WORK OUTLINED IN THESE NOTES IN ALL AREAS OF CONSTRUCTION UNLESS NOTED OTHERWISE IN THESE DOCUMENTS.
2. CEILING ELEMENTS (LIGHTING FIXTURES, MECHANICAL DIFFUSERS, SPRINKLER HEADS, ETC. ARE SHOWN FOR LAYOUT AND DESIGN INTENT ONLY. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION.
3. CEILING HEIGHTS DETERMINED IN BASE BUILDING DOCUMENTS.
4. SWITCHES ARE TO BE MOUNTED TO ALIGN WITH THE CENTERLINE OF THE DOOR LEVER 42" AFF. EACH ROOM TO BE SWITCHED INDIVIDUALLY UNLESS NOTED OTHERWISE.
5. ALL ADJACENT SWITCHES SHALL BE GANGED IN A SINGLE BOX WITH A SINGLE COVER PLATE. IF GANGING OF SWITCHES IS NOT POSSIBLE, INDIVIDUAL SWITCHES SHALL BE SPACED AN EQUAL AND MINIMUM DISTANCE APART AND LOCATED AT THE SAME ELEVATION AFF. STACKING OF SWITCHES MAY BE NECESSARY IF THE NUMBER IS EXCESSIVE.
6. DESIGN MECHANICAL SYSTEM TO PROVIDE SEPARATE ZONING FOR EACH EXPOSURE. BALANCE ALL ZONES AFFECTED BY CONSTRUCTION. PROVIDE TEST AND BALANCE REPORT TO BUILDING OWNER AND ARCHITECT FOR REVIEW. A COPY OF THE BALANCE INFORMATION SHALL BE SUBMITTED TO BUILDING REPRESENTATIVE UPON COMPLETION OF THE WORK.
7. ALL ABOVE CEILING SYSTEMS SHALL BE DESIGNED TO ACCOMMODATE CEILING HEIGHTS DOCUMENTED AND CEILING FIXTURES SPECIFIED. CEILING DROPS WILL NOT BE CONSIDERED TO ACCOMMODATE REROUTING OF SYSTEMS.
8. FOR SIMILAR FIXTURES, LAMP TYPE AND WATTAGE TO MATCH THROUGHOUT ENTIRE SPACE.
9. REFER TO ENLARGED PLAN SHEETS FOR INDIVIDUAL UNIT PLAN INFORMATION.
10. THESE DRAWINGS REPRESENT LIGHTING LOCATIONS, TYPES, AND QUANTITIES ONLY AND ARE NOT INTENDED TO DICTATE NUMBERS OF FIXTURES ON A CIRCUIT. REFERENCE ELECTRICAL SUBCONTRACTOR'S DRAWINGS FOR CIRCUITING LAYOUTS.
11. REFERENCE HVAC MECHANICAL SUBCONTRACTOR'S DRAWINGS FOR HVAC REQUIREMENTS AND GRILLE/DIFFUSER LAYOUTS.
12. DUE TO ACTUAL FIELD LOCATIONS OF EXISTING DUCTWORK OR OTHER ELEMENTS, THERE MAY BE CONFLICTS WITH INTENDED NEW LIGHT FIXTURE LOCATIONS.
13. LIGHT FIXTURE PLACEMENTS INDICATED ON REFLECTED CEILING PLANS TAKE PRIORITY OVER ANY OTHER NEW CEILING FIXTURE PLACEMENT, INCLUDING BUT NOT LIMITED TO SPEAKERS, AIR GRILLES, DIFFUSERS, EXIT SIGNS, AND SPRINKLERS. IN CASE OF ACONFLICT, REQUEST CLARIFICATION FROM DESIGNER PRIOR TO PROCEEDING WITH INSTALLATION.
14. CONTRACTOR TO SUBMIT CUT SHEETS AND TECHNICAL DATA ON ALL LIGHT FIXTURES SPECIFIED TO ANDERSON DESIGN STUDIO PRIOR TO PURCHASE. REPLACEMENT OF LIGHT FIXTURES NOT SUBMITTED TO AND APPROVED BY ARCHITECT SHALL BE AT CONTRACTOR'S EXPENSE.
15. ALL LIGHT SWITCH COVER PLATES SHALL BE LOCATED 6" FROM INSIDE FACE OF DOOR FRAME, UNLESS NOTED OTHERWISE.
16. ALL SWITCH COVER PLATES AND DEVICES SHALL BE BUILDING STANDARD, UNLESS NOTED OTHERWISE.
17. ALL NEW EQUIPMENT HVAC, ELECTRICAL AND PLUMBING EQUIPMENT SHALL BE FREE OF DEFECTS. ANY DAMAGED OR DEFECTIVE EQUIPMENT, WHETHER BUILDING STANDARD OR SPECIAL ORDER, SHALL BE REPLACED.
18. CONTRACTOR SHALL INSURE THAT LENSES IN LIGHTING CONTRACTOR SHALL INSURE THAT LENSES IN LIGHTING PLASTIC LABELS SHALL BE REMOVED FROM FIXTURES AT PROJECT COMPLETION.
19. REFER TO THE REFLECTED CEILING PLANS LEGEND SCHEDULE FOR FIXTURE TYPES.
20. EXIT SIGNS WITH DIRECTIONAL ARROWS SHALL BE PROVIDED WHERE NECESSARY TO MEET ALL APPLICABLE CODES. REFERENCE ELECTRICAL SUBCONTRACTOR'S DRAWINGS. EXIT SIGNS SHALL BE WIRED TO BUILDING EMERGENCY GENERATOR. IN CASE A GENERATOR IS NOT AVAILABLE, CONTRACTOR SHALL PROVIDE ALL EMERGENCY FIXTURES WITH BATTERY PACKS.
21. CONTRACTOR SHALL PROVIDE AUDIBLE/ VISUAL FIRE STROBES, TIED TO BUILDING ALARM SYSTEM AS REQUIRED BY LOCAL CODE OFFICIALS. REFER TO ELECTRICAL SUBCONTRACTOR'S DRAWINGS FOR LOCATIONS.
22. ALL ACCESS PANELS IN HARD CEILING ARE TO BE FLUSH "RIMLESS" TYPE IN COLOR MATCH CEILING. CONTRACTOR IS TO SUBMIT PLAN INDICATING SIZE AND LOCATION TO INTERIOR DESIGNER FOR APPROVAL.
23. ALL LIGHTING TO BE ON DIMMERS IN AMENITY SPACES UNLESS OTHERWISE NOTED.
24. ALL VENTING DUCTS TO BE CENTERED BETWEEN FLOOR JOISTS
GENERAL NOTES
OVERALL RCP - FURRED DOWN GYP. (SEE CALLOUT ON RCP)
EXIT SIGN
Smith Gee Studio, LLC209 10th Avenue South, Suite 425
Nashville, Tennessee 37203phone: (615)739-5555
No: Date: Revision::
Pro
ject
Ad
dre
ss:
PR
ELIM
INA
RY
NO
T F
OR
CO
NSTR
UC
TIO
N
Copyright 2018 by Smith Gee Studio, LLC: All drawings and text contained in these drawings are the property of Smith Gee
Studio, LLC and cannot be used without the express written permission. Do not scale drawings, if dimensions are needed
but not shown consult architect.
No
tes:
Drawing:
9/2
0/2
018 5
:12:2
4 P
M
92
4 8
th A
ve S
, N
ash
vil
le,
TN
37
20
3
Re
tail
Ad
dit
ion
/Re
no
vati
on
fo
r R
esta
ura
nt
Clie
nt
Conta
ct
: E
mily
Layne
Thom
pson
SG
S P
roje
ct
Num
ber:
18047.0
0
Re
tail A
dd
itio
n/R
en
ov
ati
on
fo
rR
es
tau
ran
t
RCP GENERAL NOTES,LEGENDS, AND CEILINGFINISH SCHEDULE
A600
(615)
214-5
465
SG
S C
onta
ct
:Dalla
s C
audle
Schematic Design Pricing Set
Issue Date - 9/20/2018
1/4" = 1'-0"1
ENLARGED - 1st Floor
Smith Gee Studio, LLC209 10th Avenue South, Suite 425
Nashville, Tennessee 37203phone: (615)739-5555
No: Date: Revision::
Pro
ject
Ad
dre
ss:
PR
ELIM
INA
RY
NO
T F
OR
CO
NSTR
UC
TIO
N
Copyright 2018 by Smith Gee Studio, LLC: All drawings and text contained in these drawings are the property of Smith Gee
Studio, LLC and cannot be used without the express written permission. Do not scale drawings, if dimensions are needed
but not shown consult architect.
No
tes:
Drawing:
9/2
0/2
018 5
:12:2
4 P
M
92
4 8
th A
ve S
, N
ash
vil
le,
TN
37
20
3
Re
tail
Ad
dit
ion
/Re
no
vati
on
fo
r R
esta
ura
nt
Clie
nt
Conta
ct
: E
mily
Layne
Thom
pson
SG
S P
roje
ct
Num
ber:
18047.0
0
Re
tail A
dd
itio
n/R
en
ov
ati
on
fo
rR
es
tau
ran
t
COVER
AG00
(615)
214-5
465
SG
S C
onta
ct
:Dalla
s C
audle
Schematic Design Pricing Set
Issue Date - 9/20/2018
All Seasons Gardening and Brewing Supply
Retail Addition/Renovation forRestaurant
Schematic Design Pricing Set
924 8th Ave S, Nashville, TN 37203
DRAWING INDEXSheet Discipline # NUMBER SHEET NAME PERMIT SET REVISION # LAST ISSUE DATE
GENERAL
00 GENERAL AG00 COVER TBD
00 GENERAL AG03 CODE ANALYSIS TBD
ARCHITECTURAL
03 ARCHITECTURE A100 DEMO PLAN TBD
03 ARCHITECTURE A101 FIRST FLOOR PLAN TBD
03 ARCHITECTURE A101a ENLARGED FIRST FLOOR TBD
03 ARCHITECTURE A105 ROOF PLAN TBD
03 ARCHITECTURE A220 DOOR, WINDOW, AND STOREFRONT TYPES & SCHEDULE TBD
03 ARCHITECTURE A300 EXTERIOR ELEVATIONS TBD
03 ARCHITECTURE A400 OVERALL BUILDING SECTIONS TBD
03 ARCHITECTURE A600 RCP GENERAL NOTES, LEGENDS, AND CEILING FINISH SCHEDULE TBD
METROPOLITAN NASHVILLE, TENNESSEE
2012 INTERNATIONAL BUILDING CODE WITH LOCAL AMENDMENTS*2012 INTERNATIONAL PLUMBING CODE WITH LOCAL AMENDMENTS*2012 INTERNATIONAL MECHANICAL CODE WITH LOCAL AMENDMENTS*2012 INTERNATIONAL FUEL GAS CODE WITH LOCAL AMENDMENTS*2012 INTERNATIONAL FIRE CODE WITH LOCAL AMENDMENTS**2012 LIFE SAFETY CODE (NFPA 101) WITH LOCAL AMENDMENTS **2011 NATIONAL ELECTRICAL CODE WITH LOCAL AMENDMENTS*2012 INTERNATIONAL ENERGY CONSERVATION CODE2009 ICC/ANSI A-117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES2012 INTERNATIONAL RESIDENTIAL CODE WITH LOCAL AMENDMENTS*
* See Chapter 16 of Metro Code of Laws for Local Code Amendment** See Chapter 10 of Metro Code of Laws for Adopted and Local Amendments*** See Chapter 17 of Metro Code of Laws for Zoning Text
APPLICABLE CODES
EX. TOILET
EX. TOILET
NEWTOILET
CLOS.
STAIR
VEST.
TYPE OF CONSTRUCTION:TYPE VB (UNSPRINKLERED) EXISTING BUILDING ADDITION/ RENOVATION
USE AND OCCUPANCY CLASSIFICATION (IBC 310.4):EXISTING - M MERCANTILE -NEW - GROUP A2 ASSEMBLY AND MERCANTILE
BUILDING AREA:ALLOWED: GROUP A2 1 STORY 6000 SF PER TABLE 503PROVIDED: EXISTING 4806 SF + 642 SF ADDITION = 5448 SF
BUILDING HEIGHT:ALLOWED: 40' PER TABLE 503 PROVIDED: 16'-9"
AREA BY OCCUPANCY USECONDITIONED SPACE (NEW ) 131.6 OCCUPANTSASSEMBLY TABLES/CHAIRS: 1015 NSF/15 = 67.7KITCHEN USE: 724 GSF/200 = 3.6MERCANTILE USE: 1700 GSF/30 = 56.7STORAGE/STOCK/UTILITY: 1100 GSF/300 = 3.6INCLUDES OCCUPIABLE ATTIC AREA
CONDITIONED SPACE (NEW -PHASE 1) 24.7 OCCUPANTS STORAGE/STOCK/UTILITY: 267 GSF/300 = 1.0SOLARIUM/RETAIL 711 GSF/30 = 23.7
157 OCCUPANTS INSIDE
UNCONDITIONED SPACE ASSEMBLY TABLES/CHAIRS: 900 NSF/15 = 60 OCCUPANTS OUTSIDE
TOTAL OCCUPANT LOAD - 217 OCCUPANTS
EGRESS EVALUATION
ALL AREAS EXCEPT THE MAIN RETAIL/RESTAURANT AREA - REQUIRE ONLY ONE MEANS OF EGRESS.
EXIT SEPARATIONDIAGONAL OF OVERALL SPACE: REFERENCE DRAWINGS UNSPRINKLED HALF THE DISTANCE: REFERENCE DRAWINGS
GREATEST TRAVEL DISTANCE:DISTANCE ALLOWED TO EXIT: 200' MAX UNSPRINKLEREDMAX DISTANCE - REFERENCE DRAWING
DEAD END CORRIDOR:DISTANCE ALLOWED: 20'-0" MAX UNSPRINKLEREDN/A
COMMON PATH OF TRAVEL:DISTANCE ALLOWED: 75'-0" MAX UNSPRINKLEREDN/A
PARKING REQUIREMENTSRESTAURANT - INDOOR AND OUTDOOR AREA - 3100 SF
(- FIRST 1000 SF)2100 SF/150 = 14 SPACES
MERCANTILE AND STORAGE - 3778 SF
(- FIRST 4000 SF) = 0 SPACES
SIDEWALK AND TRANSIT DISCOUNT -4.3 SPACES
10 SPACES REQUIRED
PROVIDED - 14 PAVED SPACES AND 4 EMPLOYEE SPACES AT THE ALLEY2% REQUIRED TO BE HANDICAPPED - 1 SPACE PROVIDED
PLUMBING REQUIREMENTSASSEMBLY USE - 132 OCCUPANTS/66 EACH SEXTOILETS - 1 EACH REQUIREDMERCANTILE USE - 85 OCCUPANTS - 1/500TOILETS - 1 REQUIRED
THREE PROVIDED, TWO ACCESSIBLELAVATORIES - 2 REQUIRED
THREE PROVIDED, TWO ACCESSIBLEDRINKING FOUNTAINS - NONE REQUIRED - PROVIDING WATER AT NO
COST, ONE WALL FOUNTAIN PROVIDEDSERVICE SINK - 1 REQUIRED - TWO PROVIDED
BUILDING DATA -
F2
WALL RATINGS -PER TYPE III-B CONSTRUCTION THE FOLLOWING WALL RATINGS ARE REQUIRED:
COLUMNS/BEAMS/GIRDERS/TRUSSES 0 HOUREXTERIOR BEARING WALLS 2 HOUREXTERIOR NON-BEARING WALLS (TABLE 602)
< 5' SEPARATION DISTANCE 1 HOUR> 5' & < 10' SEPARATION DISTANCE 1 HOUR> 10' & < 30' SEPARATION DISTANCE 1 HOUR> 30' SEPARATION DISTANCE 0 HOUR
INTERIOR BEARING WALLS 0 HOURINTERIOR NON-BEARING WALLS AND PARTITIONS 0 HOURFLOOR & FLOOR/CEILING ASSEMBLIES 0 HOURROOF & ROOF/CEILING ASSEMBLIES 0 HOUR
FIRE EXTINGUISHERS:PROVIDE SPECIFIED FIRE EXTINGUISHERS IN FULLYRECESSED CABINET AS INDICATED ON PLAN. FIREEXTINGUISHER LOCATIONS ARE HIGHLIGHTED ON THE LIFESAFETY PLAN WITH THIS SYMBOL.
PROVIDE SPECIFIED WALL MOUNTED FIRE EXTINGUISHERS INAS INDICATED ON PLAN. FIRE EXTINGUISHER LOCATIONS AREHIGHLIGHTED ON THE LIFE SAFETY PLAN WITH THISSYMBOL.
F1
ATTIC
3-HOUR RATED WALL
LIFE SAFETY LEGEND
2-HOUR RATED WALL
F1
POINT OF FARTHEST TRAVEL DISTANCE
FIRE EXTINGUISHER CABINET, PROVIDE 1 HOUR RECESSED FIRE EXTINGUISHER CABINET AT MAXIMUM 75' AS REQUIRED
FIRE EXTINGUISHER, SURFACE MOUNTED
NOTE: EXTINGUISHER CABINET LAYOUTS ARE BASED ON 2A20 BC FIRE EXTINGUISHER RATINGS.
COMMON PATH OF TRAVEL (125' MAX.)
TRAVEL DISTANCE - (250' MAX.)
POINT OF EXIT DISCHARGE
1-HOUR RATED WALL
NOTE: OVERALL PLANS FOR REFERENCE ONLY. REFER TO ENLARGED PLANS FOR ALL DIMENSIONS
NOTE: PROVIDE EXTINGUISHER UNDER COUNTER FOR EACH UNIT, TYP.
4-HOUR RATED WALL
VISUAL / HEARING IMPAIRED UNITHV
F2
Smith Gee Studio, LLC209 10th Avenue South, Suite 425
Nashville, Tennessee 37203phone: (615)739-5555
No: Date: Revision::
Pro
ject
Ad
dre
ss:
PR
ELIM
INA
RY
NO
T F
OR
CO
NSTR
UC
TIO
N
Copyright 2018 by Smith Gee Studio, LLC: All drawings and text contained in these drawings are the property of Smith Gee
Studio, LLC and cannot be used without the express written permission. Do not scale drawings, if dimensions are needed
but not shown consult architect.
No
tes:
Drawing:
9/2
0/2
018 5
:12:2
5 P
M
92
4 8
th A
ve S
, N
ash
vil
le,
TN
37
20
3
Re
tail
Ad
dit
ion
/Re
no
vati
on
fo
r R
esta
ura
nt
Clie
nt
Conta
ct
: E
mily
Layne
Thom
pson
SG
S P
roje
ct
Num
ber:
18047.0
0
Re
tail A
dd
itio
n/R
en
ov
ati
on
fo
rR
es
tau
ran
t
CODE ANALYSIS
AG03
(615)
214-5
465
SG
S C
onta
ct
:Dalla
s C
audle
Schematic Design Pricing Set
Issue Date - 9/20/2018
3/16" = 1'-0"1
FIRST FLOOR LIFE SAFETY PLAN
3/16" = 1'-0"2
ATTIC
LIMITED AREA IS OCCUPIABLE SPACE