![Page 1: SCHNABEL DC Consultants India - greenbusinesscentre.com · SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010 CII - Energy Efficiency Summit 2010. Data Center Planning](https://reader033.vdocuments.net/reader033/viewer/2022052720/5f08ffbf7e708231d424be7d/html5/thumbnails/1.jpg)
Technical Building Systems Security SystemsData Center Planning
Data Center Cooling Technology
SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010
CII - Energy Efficiency Summit 2010
![Page 2: SCHNABEL DC Consultants India - greenbusinesscentre.com · SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010 CII - Energy Efficiency Summit 2010. Data Center Planning](https://reader033.vdocuments.net/reader033/viewer/2022052720/5f08ffbf7e708231d424be7d/html5/thumbnails/2.jpg)
Technical Building Systems Security SystemsData Center Planning
3
1
3
Introduction
Air Conditioning
44
45
“The Process of Treating Air in an Indoor Environment to Establish and Maintain Required Standards of Temperature, Humidity, Cleanliness and Motion”
![Page 3: SCHNABEL DC Consultants India - greenbusinesscentre.com · SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010 CII - Energy Efficiency Summit 2010. Data Center Planning](https://reader033.vdocuments.net/reader033/viewer/2022052720/5f08ffbf7e708231d424be7d/html5/thumbnails/3.jpg)
Technical Building Systems Security SystemsData Center Planning
3
1
3
Introduction
Environment Criteria – Temperature and Humidity
Parameter2004
Version2008
VersionLow End
Temperature20°C 18°C
44
45
Temperature20°C 18°C
High End Temperature
25°C 27°C
Low End Moisture
40% RH 5.5°C DP
High End Moisture
50% RH60% RH and
15°C DP
![Page 4: SCHNABEL DC Consultants India - greenbusinesscentre.com · SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010 CII - Energy Efficiency Summit 2010. Data Center Planning](https://reader033.vdocuments.net/reader033/viewer/2022052720/5f08ffbf7e708231d424be7d/html5/thumbnails/4.jpg)
Technical Building Systems Security SystemsData Center Planning
3
1
3
Introduction
Environment Criteria – Cleanliness
� Gaseous Contamination - Severity level G1 as per ANSI/ISA – 71.04 – 1985
� Particulate Contamination - Cleanliness level as per ISO14644 Class 8
44
45
- Cleanliness level as per ISO14644 Class 8- Deliquescent Relative Humidity of the Particulate Contaminate Should be
more than 60%- Data Center must be Free of Zinc Whiskers
![Page 5: SCHNABEL DC Consultants India - greenbusinesscentre.com · SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010 CII - Energy Efficiency Summit 2010. Data Center Planning](https://reader033.vdocuments.net/reader033/viewer/2022052720/5f08ffbf7e708231d424be7d/html5/thumbnails/5.jpg)
Technical Building Systems Security SystemsData Center Planning
3
1
3
Classic DC Cooling Methodology
44
45
![Page 6: SCHNABEL DC Consultants India - greenbusinesscentre.com · SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010 CII - Energy Efficiency Summit 2010. Data Center Planning](https://reader033.vdocuments.net/reader033/viewer/2022052720/5f08ffbf7e708231d424be7d/html5/thumbnails/6.jpg)
Technical Building Systems Security SystemsData Center Planning
3
1
3
Optimised DC Cooling Methodology
Isolation of Airstreams
44
45
Chimney Racks
Cold Aisle Containment
Hot Aisle Containment
![Page 7: SCHNABEL DC Consultants India - greenbusinesscentre.com · SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010 CII - Energy Efficiency Summit 2010. Data Center Planning](https://reader033.vdocuments.net/reader033/viewer/2022052720/5f08ffbf7e708231d424be7d/html5/thumbnails/7.jpg)
Technical Building Systems Security SystemsData Center Planning
3
1
3
Optimised DC Cooling Methodology
Moving Cooling Coil Closer to Load
44
45
Over Head Cooling Rear Door Heat ExchangerIn row Cooling
![Page 8: SCHNABEL DC Consultants India - greenbusinesscentre.com · SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010 CII - Energy Efficiency Summit 2010. Data Center Planning](https://reader033.vdocuments.net/reader033/viewer/2022052720/5f08ffbf7e708231d424be7d/html5/thumbnails/8.jpg)
Technical Building Systems Security SystemsData Center Planning
3
1
3
Optimised DC Cooling Methodology
Hybrid
44
45
Close Coupled Racks
In row Cooling withAisle Containment
Supplemental Fans
![Page 9: SCHNABEL DC Consultants India - greenbusinesscentre.com · SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010 CII - Energy Efficiency Summit 2010. Data Center Planning](https://reader033.vdocuments.net/reader033/viewer/2022052720/5f08ffbf7e708231d424be7d/html5/thumbnails/9.jpg)
Technical Building Systems Security SystemsData Center Planning
3
1
3
DC Energy Efficiency
Data Center Efficiency Metrics
� DCiE = IT Equipment Energy / Total Facility Energy
Standard Good Better.5 .7 .9
44
45� PUE = 1/ DCiE = Total Facility Energy / IT Equipment Energy
Standard Good Better2.0 1.4 1.1
.5 .7 .9
![Page 10: SCHNABEL DC Consultants India - greenbusinesscentre.com · SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010 CII - Energy Efficiency Summit 2010. Data Center Planning](https://reader033.vdocuments.net/reader033/viewer/2022052720/5f08ffbf7e708231d424be7d/html5/thumbnails/10.jpg)
Technical Building Systems Security SystemsData Center Planning
3
1
3
DC Energy Efficiency
Climate Zones - ASHRAE Standards 90.1-2007 and 90.2-2007
44
45
![Page 11: SCHNABEL DC Consultants India - greenbusinesscentre.com · SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010 CII - Energy Efficiency Summit 2010. Data Center Planning](https://reader033.vdocuments.net/reader033/viewer/2022052720/5f08ffbf7e708231d424be7d/html5/thumbnails/11.jpg)
Technical Building Systems Security SystemsData Center Planning
3
1
3
DC Energy Efficiency
DCiE by Climate Zone & Data Center Type, ASHRAE TC9.9 Committee
44
45
![Page 12: SCHNABEL DC Consultants India - greenbusinesscentre.com · SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010 CII - Energy Efficiency Summit 2010. Data Center Planning](https://reader033.vdocuments.net/reader033/viewer/2022052720/5f08ffbf7e708231d424be7d/html5/thumbnails/12.jpg)
Technical Building Systems Security SystemsData Center Planning
3
1
3
DC Energy Efficiency
Mechanical System Efficiency Metrics
� PUE Mechanical = Energy Mechanical / Energy IT
� Recommended PUE Mechanical as per Climatic Zone =0.55
44
45
as per Climatic Zone =0.55
� Mechanical System Effectiveness = KWh/yr IT /kWh/yr HVAC
Standard Good Better
0.7 1.4 2.5
![Page 13: SCHNABEL DC Consultants India - greenbusinesscentre.com · SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010 CII - Energy Efficiency Summit 2010. Data Center Planning](https://reader033.vdocuments.net/reader033/viewer/2022052720/5f08ffbf7e708231d424be7d/html5/thumbnails/13.jpg)
Technical Building Systems Security SystemsData Center Planning
3
1
3
DC Energy Efficiency
Social Impact
44
45
![Page 14: SCHNABEL DC Consultants India - greenbusinesscentre.com · SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010 CII - Energy Efficiency Summit 2010. Data Center Planning](https://reader033.vdocuments.net/reader033/viewer/2022052720/5f08ffbf7e708231d424be7d/html5/thumbnails/14.jpg)
Technical Building Systems Security SystemsData Center Planning
3
1
3
Energy Efficiency
CII Initiative
“Energy Efficiency Guidelines and Best Practices in Indian Data Centers”
44
45
![Page 15: SCHNABEL DC Consultants India - greenbusinesscentre.com · SCHNABEL DC Consultants India Sreekumar K M, Consultant 02.09.2010 CII - Energy Efficiency Summit 2010. Data Center Planning](https://reader033.vdocuments.net/reader033/viewer/2022052720/5f08ffbf7e708231d424be7d/html5/thumbnails/15.jpg)
Technical Building Systems Security SystemsData Center Planning
3
1
3Thank You
44
45
SCHNABEL DC Consultants India Pvt. Ltd.Bangalore Mumbai
Phone: +91-80-42471000Fax: +91-80-42471088
www.schnabelag.in
Sreekumar Kollara [email protected]