schneider electric oem product offer

16
Schneider Electric OEM Product Offer “Make the Most of your Energy” Page 1 Confidential Property of Schneider Electric |

Upload: others

Post on 15-Jan-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Schneider Electric OEM Product Offer

“Make the Most of your Energy”

Page 1Confidential Property of Schneider Electric |

Page 2Confidential Property of Schneider Electric |

Metalclad Offer

Semi-Assembled Switchgear

OEM Structures

Cradles

Vacuum Circuit Breakers

Metal-enclosed Offer

Semi-assembled

OEM Switches

Contents

Page 3Confidential Property of Schneider Electric |

Medium Voltage Metalclad Switchgear Offer

MasterCladCORE OEM Switchgear OEM Components

Fully – Assembled Semi – Assembled Structures Cradles Vacuum Circuit Breakers

Page 4Confidential Property of Schneider Electric |

Medium Voltage Metalclad Switchgear Offer

MasterCladCORE OEM Switchgear OEM Components

Fully –Assembled

Semi –Assembled Structures Cradles Vacuum Circuit Breakers

UL

Rated Voltage 5/15kV5/15kV (Arc Res)27kV

5/15kV27kV

5/15kV27kV

5/15kV27kV

5/15kV27kV

Rated Current 1200A2000A3000A4000A

1200A2000A3000A

1200A2000A3000A

1200A2000A3000A

1200A2000A3000A4000A

Interrupting Up to 63kA(40kA @ 27kV)

Up to 63kA(40kA @ 27kV)

Up to 50kA(40kA @ 27kV)

- Up to 63kA(40kA @ 27kV)

Application IndoorOutdoor

IndoorOutdoor

Indoor - -

LV Wiring Yes Optional No - -

Doors Yes Optional Ordered separately - -

Circuit Breakers Included Included Ordered separately - -

Lead Time 14-16 weeks 10-12 weeks 6-8 weeks 4-6 weeks 4-6 weeks

StandardsIEEE/ ANSI C37.20.2IEEE/ ANSI C37.20.7 (Arc Resistant)

OEM Value Add Options (can be removed by SE) • Doors• CTs, VTs, CPTs

Accessories• Lightning arresters• Ground Studs

Page 5Confidential Property of Schneider Electric |

Semi-AssembledMasterclad Switchgear without LV control wiring ready for OEM value add

Voltage Class 5 - 15kV 27kV

Continuous Current

1200A 2000A 3000A*4000A**

1200A2000A2750A#

Interrupting Current

25 kA, 40kA, 50kA, 63kA 16kA, 25kA, 40kA

Enclosure Type NEMA 1, 3R, Arc-resistant NEMA 1, 3R

* One-high construction only** One high NEMA 1, passive arc resistant construction# 27.0 kV, 2750A Non - UL Listed Rating

Not Included• Side sheets

‒ Top/bottom pans• LV Wiring• Doors• Bus• CTs, CPTs, VTs

5-15kV Layout Configurations*see SW-OEM Price Guide for 27kV

Page 6Confidential Property of Schneider Electric |

OEM StructuresPre-configured 2-high metalclad switchgear structures ready for OEM value add

Ratings• 5/15kV 3000A 50kA max • 27kV 2000 40kA max

Included• Copper ground bus• Glass polyester insulating bushings (porcelain

available)• Secondary control wiring bundled with wire

markers• Shutter locking provisions for both key interlock

and padlock

OptionsFactory wired

‒ MOC Switch‒ TOC Switch

Shipped Loose‒ Capacitor Trip Unit‒ Shutter Barrier Assembly‒ Test Cabinet‒ Lift Truck‒ Racking handle

Page 7Confidential Property of Schneider Electric |

VR Circuit Breaker CradleEnabling OEM to leverage their own switchgear design

Also available as a loose part kit.

Page 8Confidential Property of Schneider Electric |

VT – CPT – Fuse Truck• Drawout truck with secondary disconnects• Rails to mount into auxiliary cubicle• Set of primary disconnects (stationary and

movable) with glass polyester insulators• Primary barrier between stationary primary

disconnects and truck• Barriers at rear between cell and bussing

compartment (with porcelain cable guides and primary cable)

• Shipped fully-assembled

Auxiliary Cradles and TrucksVT - CPT – Fuse compartments available complete or bare

Blank Truck• Ready for OEM Value Add• VT, CPT or Fuses not included• Direct fit into auxiliary cradle

Auxiliary Cradle• Cut-out in cell for primary cable

connection barrier to isolate double VT • Horizontal CPT or Fuse trucks in one cell• Hinges for customer-supplied doors • UL Recognized components

StandardsANSI/IEEE C37.06, C37.09, and C37.54ANSI/IEEE C37.013A (Generator Switching)ANSI/IEEE C1 Cap Switching @ 410A

Ratings• 5/15kV 4000A 63kA max• 27kV 2750A 40kA max

Standard Features• 3-cycle interrupting rating• UL Listed• Spring-charged, stored-energy operating mechanism• Permanently mounted manual charging handle• Two “a” and “b” spare contacts• Wheels that roll directly to floor level from lower cell for maintenance

Benefits• Special wheel design allows for easy maneuvering of the breaker in

the rail channel support internal to the breaker section• Maintenance requirements are minimized via enclosed long-life

vacuum interrupters • The inherent rigidity and mechanical strength of the circuit breaker

design complement the operating mechanism, resulting in high endurance and reliability

• Allows for customized system designs and applications

Page 9Confidential Property of Schneider Electric |

VR Circuit BreakerIndustry-proven vacuum circuit breaker

Page 10Confidential Property of Schneider Electric |

Metalclad Offer

Semi-Assembled Switchgear

OEM Structures

Cradles

Vacuum Circuit Breakers

Metal-enclosed Offer

Semi-assembled

OEM Switches

Next – Metal Enclosed

Medium Voltage Metal Enclosed Switchgear Offer

Page 11Confidential Property of Schneider Electric |

Medium Voltage Metal Enclosed Switchgear Offer

HVLHVL/cc

CORE OEM Switchgear OEM Components

Fully – Assembled HVLSemi – Assembled

HVL/ccSemi –

Assembled

HVLComponents

HVL/ccComponents

Medium Voltage Metal Enclosed Switchgear Offer

Page 12Confidential Property of Schneider Electric |

Medium Voltage Metal Enclosed Switchgear Offer

HVLHVL/cc

CORE OEM Switchgear OEM Components

Fully – Assembled HVLSemi – Assembled

HVL/ccSemi – Assembled

HVLSwitch

HVL/ccSwitch

Switch Rated Voltage

5/15kV27kV38kV

5/15kV27kV38kV

5/15/15kV27kV38kV

5/15kV27kV

Rated Current 400 - 1200A 400 - 1200A 600 - 1200A600A @ 34.5kV

600 - 1200A600A @ 25.8-38kV

Max Short Circuit 50kA @ 15kV25kA @ 27-38kV

50kA @ 15kV25kA @ 27-38kV

50kA @ 15kV25kA @ 27-38kV

40kA fault close @ 15kV32kA fault close @ 27-38kV

Application IndoorOutdoor

IndoorOutdoor - -

Fully wired Yes Optional - -

Doors Yes Optional - -

Fusing Optional Optional Not includedDIN-E or Boric Acid

Not includedDIN-E

Lead Time 10-16 weeks 10-16 weeks 4-8 weeks 4-8 weeks

Page 13Confidential Property of Schneider Electric |

Semi-Assembled SwitchgearHVL & HVL/cc options for load break switching with power fuse protection

HVLSquare D’s original open air switchgear for visual confirmation of load interruption. Power fuses provide short circuit protection. Interlocks ensure that the switch and fuse compartment remains closed until the switch is opened.

HVL/ccThe smallest footprint switchgear in the power distribution market. Its compact Class 1 Div 2 design uses a factory sealed sulfur hexafluoride compartment for load break switching and power fuses for short circuit protection.

Page 14Confidential Property of Schneider Electric |

Catalog Number 5kV-38kV● Open Style Switch (OTM)● Upright or inverted● Fusible or Non-fusible● Glass Poly (standard) or Porcelain

Insulators (optional)● Reference pricing guide for additional

accessories● 2NO/2NC aux contacts● Cable Lugs● Fuses● Phase barriers

● Lead-times● 3-4 weeks

HVL Switch

Page 15Confidential Property of Schneider Electric |

Open style switch• 15kV, 600A & 1200A, 40kA fault close• 27kV & 38kV 600A, 32kA fault close• 2 types of mechanism

‒ OTM: Over Toggle Mech‒ SEM: Stored Energy Mech

• Grounding position available• DIN/E size fuses or non-fused• Reference pricing guide for additional accessories

• Load connections• Boots, • Live Line Indicators

HVL/cc SwitchHVL/cc