scientific session 23 portal venous intervention

2
200 (6.1% vs 15.7% at 1 year, 6.1% vs 27.3% at 2 years, respectively) . CONCLUSION Catheter fixation method improves cath- eter stability and HA patency, and enables patients to undergo long-term arterial infusion. Scientific Session 23 Portal Venous Intervention Moderator: Robert K. Kerlan, Jr., MD 1:00 pm Effect of IV Vasopressin on the Portosystemic Gradient During TIPS Michael C. Soulen, Philadelphia, PA PURPOSE: Systemic vasopressin decreases portal venous pressure 200/0-30% and is used to treat acute variceal bleeding. This study evaluated whether pharmacologic suppression of portal pressure alters the portosystemic gradient, which is used as an endpoint during TIPS placement. METHODS: Nine patients underwent TIPS for variceal bleeding while receiving IV vasopressin. Portal vein and right atrial pressures were measured after TIPS placement, and again 20 minutes after weaning off the vasopressin infusion. Splenic venograms were also performed before and after withdrawal of vasopressin. RESULTS: Eight patients were receiving vasopressin at 0.4 units/min and one at 0.2 u/min. TIPS was success- ful in all cases. After stopping vasopressin the porto- systemic gradient increased in six of the nine patients. In three patients, the gradient rose from mmHg to 14-17 mmHg. The mean portosystemic gradient after TIPS placement was 9.3 ± 4.4 mmHg (S.D.), range 4-15 mmHg. After weaning off vasopressin, the mean portosystemic gradient was 10.3 ± 4.6 mmHg, range 4-17 mmHg (p = 0.45). There was no qualitative change in variceal opacification after stopping vaso- pressin. CONCLUSION On average, the portosystemic gradient across a TIPS is not significantly altered by systemic vasopressin. However, in some cases the gradient rises above the endpoint of 12 mmHg when vasopressin is withdrawn. 1:15 pm Intraluminal Irradiation for TIPS Stenosis: Results in a Swine Model Todd Lessie, MD, Salt Lake City, UT. Howard Nelson, MD Franklin j. Miller, MD. David Fillmore, MD. Hyo-Chun Yoon, MD, PhD PURPOSE: To evaluate the ability of 32Phosphorus in- traluminal irradiation to reduce pseudointimal hyperpla- sia (PIB) in TIPS. MATERIALS AND METHODS: TIPS were successfully placed in eleven swine with normal portal pressures. Six animals received 16 Gy intraluminal irradiation to the hepatic parenchyma and venous outflow tract at the time of TIPS placement using a Sodium 32Phosphorus e 2 p) filled balloon angioplasty catheter. Five control animals underwent TIPS and balloon angioplasty with saline. All animals were followed for 28 days, at which time per- cutaneous portography was performed, animals sacri- ficed, and the tissue around the TIPS stent processed for histologic analysis. Maximum PIH as a percentage of estimated TIPS diameter was calculated for each animal. RESULTS: At the time of sacrifice, all five control TIPS and all but one irradiated TIPS were occluded. Histologic analysis demonstrated considerable variability in the de- gree of pseudointimal hyperplasia within each TIPS and between animals. No significant difference was found in the maximum PIH between control and irradiated ani- mals. CONCLUSIONS: Irradiation of TIPS with 16 Gy 32p deliv- ered at the time of TIPS placement did not significantly improve TIPS patency or reduce the degree of pseudo- intimal hyperplasia in swine with normal portal pres- sures. 1:30 pm Bile Leak in TransjuguJar Intrahepatic Portosystemic Shunt: Effect on SMC Proliferation Gao-jun Teng, MD, Lebanon, NH. Michael A. Bettmann, MD. Paul Jack Hoopes, DVM; PhD. Robert j. Wagner, MA Byeong-Ho Park, MD. Li Yang, MD PURPOSE: To evaluate the effect of bile on smooth muscle cell (SMC) proliferation in vitro and in vivo in a porcine TIPS model. MATERIAL AND METHODS: In vitro, SMCs explanted from porcine thoracic aorta were cultured utilizing stan- dard technique, and were then subcultured in one of three groups: 1% PS [porcine serum] + 1% bile; 10% PS + 1% bile; 10% PS. Cells were harvested at 3, 10 or 14 days with measurement of DNA, Protein and DPM. In vivo, TIPS was successfully performed in 45 swine. The proliferative response within the stent was histologically quantified and correlated to evidence of bile leak. RESULTS: From pilot studies, 2.5-10% bile solutions caused 100% SMC mortality by 3 days. With 1% solutions (with and without PS), both DNA and protein production decreased significantly compared to PS alone (P < .05). In the in vivo model, 13 of 45 specimens (29%) showed bile leakage by gross or microscopic examination. There was less SMC proliferation in animals with than in those without bile leak. Thrombus formation was the primary component of TIPS occlusion or stenosis in specimens with bile leak, while myofibroblastic proliferation was the major component in the group without bile leak.

Upload: buiminh

Post on 30-Dec-2016

225 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Scientific Session 23 Portal Venous Intervention

200

(6.1% vs 15.7% at 1 year, 6.1% vs 27.3% at 2 years,respectively) .

CONCLUSION Catheter fixation method improves cath­eter stability and HA patency, and enables patients to

undergo long-term arterial infusion.

Scientific Session 23Portal Venous InterventionModerator: Robert K. Kerlan, Jr., MD

1:00 pm

Effect of IV Vasopressin on the PortosystemicGradient During TIPSMichael C. Soulen, Philadelphia, PA

PURPOSE: Systemic vasopressin decreases portal venous

pressure 200/0-30% and is used to treat acute variceal

bleeding. This study evaluated whether pharmacologic

suppression of portal pressure alters the portosystemicgradient, which is used as an endpoint during TIPS

placement.

METHODS: Nine patients underwent TIPS for variceal

bleeding while receiving IV vasopressin. Portal vein

and right atrial pressures were measured after TIPS

placement, and again 20 minutes after weaning off the

vasopressin infusion. Splenic venograms were alsoperformed before and after withdrawal of vasopressin.

RESULTS: Eight patients were receiving vasopressin at

0.4 units/min and one at 0.2 u/min. TIPS was success­

ful in all cases. After stopping vasopressin the porto­

systemic gradient increased in six of the nine patients.

In three patients, the gradient rose from ~12 mmHg to

14-17 mmHg. The mean portosystemic gradient afterTIPS placement was 9.3 ± 4.4 mmHg (S.D.), range4-15 mmHg. After weaning off vasopressin, the meanportosystemic gradient was 10.3 ± 4.6 mmHg, range4-17 mmHg (p = 0.45). There was no qualitativechange in variceal opacification after stopping vaso­pressin.

CONCLUSION On average, the portosystemic gradientacross a TIPS is not significantly altered by systemic

vasopressin. However, in some cases the gradient rises

above the endpoint of 12 mmHg when vasopressin is

withdrawn.

1:15 pm

Intraluminal Irradiation for TIPS Stenosis: Resultsin a Swine ModelTodd Lessie, MD, Salt Lake City, UT. Howard Nelson,MD • Franklin j. Miller, MD. David Fillmore, MD.

Hyo-Chun Yoon, MD, PhD

PURPOSE: To evaluate the ability of 32Phosphorus in­

traluminal irradiation to reduce pseudointimal hyperpla­

sia (PIB) in TIPS.

MATERIALS AND METHODS: TIPS were successfullyplaced in eleven swine with normal portal pressures. Six

animals received 16 Gy intraluminal irradiation to the

hepatic parenchyma and venous outflow tract at the timeof TIPS placement using a Sodium 32Phosphorus e2p)

filled balloon angioplasty catheter. Five control animalsunderwent TIPS and balloon angioplasty with saline. All

animals were followed for 28 days, at which time per­

cutaneous portography was performed, animals sacri­ficed, and the tissue around the TIPS stent processed for

histologic analysis. Maximum PIH as a percentage of

estimated TIPS diameter was calculated for each animal.

RESULTS: At the time of sacrifice, all five control TIPS and

all but one irradiated TIPS were occluded. Histologic

analysis demonstrated considerable variability in the de­

gree of pseudointimal hyperplasia within each TIPS and

between animals. No significant difference was found in

the maximum PIH between control and irradiated ani­mals.

CONCLUSIONS: Irradiation of TIPS with 16 Gy 32p deliv­

ered at the time of TIPS placement did not significantly

improve TIPS patency or reduce the degree of pseudo­

intimal hyperplasia in swine with normal portal pres­sures.

1:30 pm

Bile Leak in TransjuguJar IntrahepaticPortosystemic Shunt: Effect on SMC ProliferationGao-jun Teng, MD, Lebanon, NH. Michael A.

Bettmann, MD. PaulJack Hoopes, DVM; PhD.

Robert j. Wagner, MA • Byeong-Ho Park, MD. LiYang, MD

PURPOSE: To evaluate the effect of bile on smoothmuscle cell (SMC) proliferation in vitro and in vivo in aporcine TIPS model.

MATERIAL AND METHODS: In vitro, SMCs explantedfrom porcine thoracic aorta were cultured utilizing stan­dard technique, and were then subcultured in one ofthree groups: 1% PS [porcine serum] + 1% bile; 10% PS+ 1% bile; 10% PS. Cells were harvested at 3, 10 or 14days with measurement of DNA, Protein and DPM. Invivo, TIPS was successfully performed in 45 swine. The

proliferative response within the stent was histologically

quantified and correlated to evidence of bile leak.

RESULTS: From pilot studies, 2.5-10% bile solutions

caused 100% SMC mortality by 3 days. With 1% solutions

(with and without PS), both DNA and protein production

decreased significantly compared to PS alone (P < .05).

In the in vivo model, 13 of 45 specimens (29%) showedbile leakage by gross or microscopic examination. There

was less SMC proliferation in animals with than in those

without bile leak. Thrombus formation was the primary

component of TIPS occlusion or stenosis in specimens

with bile leak, while myofibroblastic proliferation was

the major component in the group without bile leak.

Page 2: Scientific Session 23 Portal Venous Intervention

CONCLUSIONS: These data, from both in vitro and invivo studies, suggests that the proliferative response inTIPS is not primarily due to bile leak.

1:45 pm

Comparison of Polyethelene Teraphthalate (PET)Covered Wallstents Versus Uncovered Wallstentsfor TIPS Creation in an Animal ModelZiv Haskal, MD, Philadelphia, PA

PURPOSE: To evaluate the safety and efficacy of a poly­ethelene teraphthalate (PET) covered Wallstent for TIPScreation in an animal model.

MATERIALS AND METHODS: Thirteen TIPS were createdin 13 minipigs: 8 lined with PET-covered Wallstents (wa­ter permeability: 750-2000 cc/cmjeP2/min), 5 with stan­dard Wallstents. Shunt venography was performed at5-8 weeks, necropsy at 7-8 weeks. Histology, immuno­histopathology, and electron microscopy was performedon the explants.

RESULTS: The devices proved equally easy to deploy. At7-8 week venography, the mean shunt stenoses of thecontrol and graft groups were 45% (range 26-83%) and53% (range 0-90%), respectively. There was 1 graft TIPSocclusion. All stenoses developed within the liver tract.One stenosis was due to trans-stent proliferation of normalporcine liver tissue. Typical myofibroblast and collagenmatrix proliferation encompassed both control and graftTIPS. There was no evidence of bile staining within thistissue. A neointima of varying thickness lined the lumina inboth groups. Slightly more pronounced inflammation waspresent at the graft ends (site of PET material fixation).

CONCLUSION This TIPS stent-graft is easy and safe toplace. Its healing response and patency, in this specificanimal model, are similar to bare stent TIPS.

2:00 pm

Percutaneous Retroperitoneal Splenorenal Shunt:An Experimental Study in SwineToshio Kaminou, MD, PhD, Portland, OR. Barry T.

Uchida, BS. ShOji Sakaguchi, MD • Dusan Pavcnik,MD, PhD. Hans A. Timmermans, BFA. Frederick S.Keller, MD

PURPOSE: To evaluate percutaneous retroperitonealsplenorenal shunt (PRESS) in swine, which potentiallycan be a new minimal invasive treatment of portal hy­pertension.

MATERIAL AND METHODS: Eight domestic swine un­derwent PRESS. A modified TIPS puncture set wasintroduced from the right femoral vein into the leftrenal vein. The proximal splenic vein was punctured.A Wallstent and a PTFE covered stent-graft were thenplaced connecting both veins through the retroperito­neal cavity. The animals were followed up weekly bysplenic venography until the shunt occluded.

RESULTS: Puncture of the splenic vein and stent place­ment was successfully completed in all cases. In seven ofeight animals, good flow from the splenic vein to the leftrenal vein through the shunt tract was observed onehour after PRESS. No changes in vital signs were noticedduring the procedure. Five of eight tracts showed ob­struction one week after PRESS. At necropsy minimalretroperitoneal hematoma along the tract were found.Stents and stent grafts were positioned in the retroperi­toneal cavity connecting both veins in all cases. Remark­able intimal hyperplasia with clots was present in thetracts.

CONCLUSIONS: Creation of a percutaneous splenorenalshunt is technically possible and further experimentalstudies of its efficacy are warranted.

2:15 pm

Portal Vein Embolization for Extension ofHepatectomy IndicationsThierry de Baere, MD, Villejuif, France. Alain Roche,

PhD. Dominique Elias, MD. Philippe Lasser, MD

PURPOSE: To render hepatectomy feasible in patientswith an initially deficient volume of the future remnantliver (FRL).

MATERIALS AND METHODS: Portal blood flow wasredistributed towards the FRL with preoperative em­bolization of the portal veins (POPE) feeding the fu­ture resected liver. POPE was performed in 38 patientswith malignant tumors and in 2 with benign lesions.POPE was performed under fluoroscopic guidance,via a percutaneous transhepatic access to the portalvein.

RESULTS: FRL volume values were 90-560 cc (m = 271cc) before POPE and 160-933 cc (m = 455 cc) afterPOPE, which represents a volume increase of 83 ± 49%.Hypertrophy of the FRL was 92% ± 62% after 31 dayswith Cyanoacrylate, 53% ± 6% after 43 days with Gel­foam, and 44 ± 30% after 35 days with coils. Slightshrinkage was obtained in the volume of the embolizedliver. POPE was well tolerated and surgery was possiblein 32 patients. Seven operations were cancelled due totumor spread, but only one due to insufficient hypertro­phy of the FRL.

CONCLUSION Although exclusively applicable in a lim­ited subset of patients, POPE widens the possibilities ofcurative hepatectomies, because it induces hypertrophyof unembolized liver segments. Among embolic materi­als, cyanoacrylate seems to ensure better and faster hy­pertrophy.

Scientific Session 24Venous ThrombolysisModerators: Martin Richard Crain, MDj Julien 1.

Struyven, MD201