Scintillation counter installation on EBC
cryostatscintillators
gap scintillators
location ofMBTSscintillators
MBTS counterswill be pluggedinto fiber assemblies for 1/8 of cryostatscintillators
MBTS trigger The goal of the trigger is to be able to
define 1(2) filled bunches in conjunction with activity from the collision point
ATLAS Tilecal trigger cables will run from extended barrel up to rack where signals will be distributed through patch panels
understanding is that gap scintillators will be separated out through own connector
Q: what is meant by gap scintillators? Sometimes cryo scintillators are termed gap. Will find out.
MBTS counters will be plugged into PMT#1 (E#) which uses the muon trigger output; this may be bundled with other Tilecal trigger signals and will require intervention to separate out
NB
We will have to remove a cryostat scintillator for each MBTS counter in order to route the MBTS pigtail to the optical fiber assemblies
Can re-install only between runs
Higain counts Higain counts
eve
nts
eve
nts
50 mV trigger threshold4.6mV/pC at end of trigger cableX5 gain in coincidence board before descriminator12.5pC = 1024 counts (higain) => 50mV threshold = 178 counts on higain output
50mV threshold
50mV threshold
Tests performed at Chicago test-bench with counter
good separation between signaland noise offline; 30-40% efficiency per counter for mip attrigger level; trigger electronics notdesigned for this kind of signal
See however next slide
Muon trigger outputsOne of the PMT channels on each module has been
modified to have a higher gain (X30) for the L1 trigger output
The pigtails are long enough that inner and outer segments can be plugged into the modified channels on two adjacent Tilecal modules
This will boost signal and will boost S/N by an unknown amount (how much of noise is upstream of additional gain?) tests suggest 75% efficiency with 90% noise
rejectionNoise problems currently with finger supplies; would like
to check once situation is stable again with new trigger cables
Trigger signals What to do with trigger signals
once they leave patch panel? Is there a reason not to use the
Chicago stand-alone boards? I think Nick had an objection but
I can’t remember what it was Otherwise, we discussed using a
VME crate (either separate or sharing space with another system) and commercial logic boards that allow different combinations to be formed
A and C, A or C, etc If need be I can look for money
for buying components Output signal then goes to CTP
Issues
From Nick’s email to Ana can test trigger outputs of EBC drawers in ~1 month will get an idea of signal to noise using muon trigger
outputsSometime later (how much later?) can use
temporary trigger cables to send signals up to USA15
Better to wait until final EBC extended barrel trigger cables are installed?
How to test counters in place? Can we bring a source down to the cavern? How to measure radiation damage/aging? Keep track of average pulse heights from counters?