Scintillation detectors performance and status report. JSPS Core to Core Program Seminar and Hall-C HKS/HES collaboration meeting 8 May 2009 T.Gogami. HKS side. HTOF2Y. HTOF1Y. It had gaps between scintillators . (~3[mm]) Event loss >=5% Redesign. The former HTOF1Y. - PowerPoint PPT PresentationTRANSCRIPT
Scintillation detectors performance and status report
JSPS Core to Core Program Seminar and
Hall-C HKS/HES collaboration meeting8 May 2009 T.Gogami
HKS side
HTOF2Y
HTOF1Y
It had gaps between scintillators.
(~3[mm])Event loss >=5%
Redesign
The former HTOF1Y
HTOF1Y with 3mm gaps between each scintillators in GEANT4
HTOF1Y Put scintillator zigzag
Position was optimized by GEANT4
K+ event loss ~0%
HTOF1YNow it was already assembled
TOF resolution σ~100[ps] HTOF1Y @ EEL124
Cosmic ray test @ EEL126
HTOF1X
TOF resolution
σ~70[ps]
cosmic ray test @EEL126
HTOF2X Check PMT performance & Light leak
Found one segment leaks light
We have to fix it some day
350h×95w×20t ×18segments HTOF2X @ EEL124
HTOF2Y
T0 counter35h×2000w×30t
I have not assembled yet.
HTOF2Y @ EEL126
HES sideEHODO3
EHODO TOF resolution
σ~130[ps] Local patch
EHODO @ EEL126
EHODO3 T0 counter timing resolution σ~100[ps]
cosmic ray test @ EEL126EHODO3 & EHODO
summary