The signals from a DIRECTV® (4) polarity SLSP-F
SlimLine® dish with SL5 LNB, DTV66E 95º dish and a
possible 6th polarity are required for multiple switches
Amplifi ers are required to increase the signal level from
the dish to feed the taps. Model SD SA-6AL-T includes
automatic gain control for a constant input to the taps.
The tap values are 16 dB, 12 dB, 9 dB and 6 dB. Model
SD MST616 tap output is 16 dB less than the input
Model SD SA-6AL amplifi ers may be spaced at (5) fl oor
increments when used with model SD MST616, SD MST612, SD MST609 and SD MST606 tap per fl oor.
The trunk level is indicated on the left and the tap level
output is indicated on the right.
Automatic gain simplifi es the design and the installation
knowing that the amplifi er output is -18 dBm when the
LED lights are Green.
DIRECTV® MULTI-TAPS
Model SD MST616, SD MST612, SD MST609 and SD MST606 multiple input taps directionally couple a
portion of trunk signals to feed single or groups of
DBS switches.
SOLUTION
RELATED CONSIDERATIONS
Indoor / Outdoor, (6) coax, 54 to 2150 MHz DBS
directional couplers. DC passive OUTPUT to INPUT.
DC blocking at the tap port.
• CATV / Ka/Ku bandwidth ........................... 2 to 2150 MHz
• High Isolation adjacent input ............................... >35 dB
• DC passing .............................................. Output to Input
• DC blocking ......................................................... Tap Port
• Outdoor case .............. (2) 10 AWG Green Ground screws
-44 dBm
-26 dBm
-30 dBm
-44 dBm
-18 dBm
-18 dBm
-22 dBm
SDMST616
-34 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST616
-38 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST612
-38 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST609
-39 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
-36 dBmSDMST606
-42 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
DC
SD SA-6ALFLEX 1 FLEX 2
FLEX 1 FLEX 2
PS12
1000
DC
SD SA-6ALFLEX 1 FLEX 2
FLEX 1 FLEX 2
PS12
1000
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
9
8
7
6
FLOOR5
FLOOR10
1 floor Tap spacing20 ft RG6 per floor5 floor Amp spacing26 dB spacing
SD MST616
SD
MS
T6
XX
(6) IN
PU
T T
AP
S
SD MST612
SD MST606
SD MST609
Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com [email protected]
Revised Aug 23 2012
2SD MST6xx SWiM (6) TRUNK TAP
PARAMETER UNIT SD MST6xx
Operating Frequency MHz 5 -2150 MHz
Number Input / Output /
Tap PortsEach 6 SCTE Indoor
DC Power Output to Input Amps 3
Ground Studs Each 2
Dimensions L x W x H mm 60 x 150 x 47
Operating Temperature ºC -34 to + 60 Indoor / Lock box
Humidity Shall survive 95% relative humidity
over operating temperature
SD MST606
6 dBInsertion Loss
In-OutInsertion Loss
In - TapIsolationOut - Tap
Return LossINPUT
Return LossOUTPUT
Return LossTAP
Port to Port Isolation
5-250 MHz 3.4 ±0.2 6.3 ±0.2 >18 dB >12 dB >12 dB >12 dB >45 dB
250-1850 MHz 4.0 ±0.2 6.5 ±0.2 >18 dB >12 dB >12 dB >12 dB >45 dB
1850-2150 MHz 5.5 ±0.2 7.2 ±0.2 >18 dB >12 dB >12 dB >12 dB >40 dB
SD MST609
9 dBInsertion Loss
In-OutInsertion Loss
In - TapIsolationOut - Tap
Return LossINPUT
Return LossOUTPUT
Return LossTAP
Port to Port Isolation
5-250 MHz 1.7 ±0.2 8.8 ±0.2 >18 dB >12 dB >12 dB >12 dB >45 dB
250-1850 MHz 2.7 ±0.2 8.8 ±0.2 >18 dB >12 dB >12 dB >12 dB >45 dB
1850-2150 MHz 4.3 ±0.2 9.0 ±0.2 >18 dB >12 dB >12 dB >12 dB >45 dB
SD MST612
12 dBInsertion Loss
In-OutInsertion Loss
In - TapIsolationOut - Tap
Return LossINPUT
Return LossOUTPUT
Return LossTAP
Port to Port Isolation
5-250 MHz 1.5 ±0.2 11.5 ±0.2 >18 dB >12 dB >12 dB >12 dB >35 dB
250-1850 MHz 1.7 ±0.2 11.6 ±0.2 >18 dB >12 dB >12 dB >12 dB >35 dB
1850-2150 MHz 1.9 ±0.2 12.1 ±0.2 >18 dB >12 dB >12 dB >12 dB >35 dB
SD MST616
16 dBInsertion Loss
In-OutInsertion Loss
In - TapIsolationOut - Tap
Return LossINPUT
Return LossOUTPUT
Return LossTAP
Port to Port Isolation
5-250 MHz 1.2 ±0.2 16 ±0.2 >18 dB >12 dB >12 dB >12 dB >35 dB
250-1850 MHz 1.6 ±0.2 15.5 ±0.2 >18 dB >12 dB >12 dB >12 dB >35 dB
1850-2150 MHz 1.9 ±0.2 15.5 ±0.2 >18 dB >11 dB >12 dB >10 dB >35 dB
Multi-Satellite Taps allow SWM expansion Chassis to be connected to a common satellite distribution backbone
SD MST6xx Trunk Tap
• (6) Trunk Capacity
• Passes DC Voltage Out-to-In
• DC Blocking on Tap Port
• 10 AWG Ground Lug
MODEL# Description UPC #SD MST606 (6) Input , 6 dB Multi-Tap 609465599014
SD MST609 (6) Input , 9 dB Multi-Tap 609465599021
SD MST612 (6) Input , 12 dB Multi-Tap 609465599038
SD MST616 (6) Input , 16 dB Multi-Tap 609465599045
Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com [email protected]
Revised Aug 23 2012
3AMPLIFIER SPACING
DC
SD SA-6ALFLEX 1 FLEX 2
FLEX 1 FLEX 2
PS12
1000
DC
SD SA-6ALFLEX 1 FLEX 2
FLEX 1 FLEX 2
PS12
1000
-18 dBm
-45 dBm
-22 dBm
-26 dBm
-31 dBm
-18 dBm
-39 dBm
SDMST616
-34 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST616
-38 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST612
-38 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST606
-37 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST616
-34 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
29
28
27
FLOOR30
FLOOR26
20 ft RG6 per floor1 floor Tap spacing5 dB ave tap loss4 taps x 5 dB =20 dB Amp Spacing
Tap per Floor, 4 Floor Amp, 20 dB SpacingThe SD SA-6AL automatic gain amplifi ers are located
at (4) fl oor (20) dB spacing. Lower tap values provide
the highest tap output per fl oor. A minimum IDF input
of -37 dBm is budgeted.
SD MST6xx / Floor, SD SA-6AL 20 dB Spacing
MHz/ dB 250 950 1450 2150RG-6 80 ft 2.5 5.1 6.3 7.7
MST616 1.0 1.3 1.4 1.9
MST616 1.0 1.3 1.4 1.9
MST612 1.5 1.8 1.9 2.1
MST606 3.4 3.8 4.5 5.5
TOTAL 8.4 13.3 15.8 20.2
The RevB SD SA-6AL internal slope compensation
off sets 12 dB of the 12 dB slope.
The PERFECT10 built D2 Advantage™ MDU boxes
contain a SD MST606 tap in front of either a SWM16 or
SWM32 switch. The tap port feeds the switch and the
through port is available to feed an additional box if
needed. The minimum IDF output equals the minimum
switch input plus 6 dB. (-45 dBm switch input - 6 dB
tap loss = -39 dBm minimum IDF output.)
Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com [email protected]
Revised Aug 23 2012
4
DC
SD SA-6ALFLEX 1 FLEX 2
FLEX 1 FLEX 2
PS12
1000
DC
SD SA-6ALFLEX 1 FLEX 2
FLEX 1 FLEX 2
PS12
1000
-18 dBm
-45 dBm
-22 dBm
-26 dBm
-30 dBm
-18 dBm
-44 dBm
SDMST616
-34 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST616
-38 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST612
-38 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST609
-39 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST616
-34 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
29
28
27
-36 dBm SDMST606
-42 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SWMBOX-xx27
FLOOR30
FLOOR26
20 ft RG6 per floor1 floor Tap spacing5 dB ave tap loss5 taps x 5 dB =25 dB Amp Spacing
Tap per Floor, 5 Floor Amp, 25 dB SpacingThe (3) SD SA-6AL automatic gain amplifi ers are located
at (5) fl oor, (25) dB spacing.
The AGC output of the SD-SA-6AL amplifi er is updated
to the equivalent of the -1 dBm composite output (-18
dBm peak at 2150 MHz).
A minimum IDF input of -42 dBm is budgeted.
SD MST6xx / Floor, SD SA-6AL 25 dB Spacing
MHz/ dB 250 950 1450 2150RG-6 100 ft 3.9 6.4 7.9 9.7
MST616 1.0 1.3 1.4 1.9
MST616 1.0 1.3 1.4 1.9
MST612 1.5 1.8 1.9 2.0
MST609 1.7 2.0 3.0 4.3
MST606 3.4 3.8 4.5 5.5
TOTAL 12.5 16.6 20.1 25.3
The new SD SA-6AL internal slope compensation
off sets 12 dB of the 13 dB slope.
SONORA tested the system to the left with live signal
to verify the calculated levels and confi rm the signal
integrety.
Spectrum analyzer plots of the 18V 22kHz, 103º, 110º &
119º even transponders were recorded at each point in
the distribuion system.
A DIRECTV AIM meter was used to confi rm signal levels
and to measure Signal to Noise Ratios.
The plot on the left is the input to the SD SA-6AL
amplif ier after 100 feet of RG-6, a SD PI-6S and
SEQ509. The transponder bands are equal in
amplitude at -47 dBm.
(5) TAP AMPLIFIER SPACING
Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com [email protected]
Revised Aug 23 2012
5
31
29
28
27
26
25
FLOOR30
FLOOR24
DC
SD SA-6ALFLEX 1 FLEX 2
FLEX 1 FLEX 2
PS12
1000
DC
SD SA-6ALFLEX 1 FLEX 2
FLEX 1 FLEX 2
PS12
1000
-18 dBm
-41 dBm
-23 dBm
-28 dBm
-18 dBm
-36 dBm
SDMST616
-34 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST612
-35 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST606
-34 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST616
-34 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
18 ft RG6 per floor2 floor Tap spacing6 dB ave tap loss3 taps x 6 dB =18 dB Amp Spacing
Tap per Alternating Floors, 6 Floor, 20 dB Amp SpacingThe 20 dB amplifier spacing splits the distribution
equally between the (2) SD SA-6AL amplifi ers. The 20
dB amplifi er spacing allows more signal to be tapped
to feed IDF closets. Lower tap values have higher trunk
insertion loss.
A minimum IDF input of -36 dBm is budgeted.
SD MST6xx / 2 Floors, SD SA-6AL 20 dB Spacing
MHz/ dB 250 950 1450 2150RG-6 100 ft 3.9 6.4 7.9 9.7
MST616 1.0 1.3 1.4 1.9
MST612 1.5 1.8 1.9 2.1
MST606 3.4 3.8 4.5 5.5
TOTAL 9.8 13.7 15.9 19.7
The new SD SA-6AL internal slope compensation off sets
12 dB of the 10 dB slope.
AMPLIFIER SPACING
Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com [email protected]
Revised Aug 23 2012
6
29
28
27
26
25
24
23
FLOOR30
FLOOR22
-45 dBm
DC
SD SA-6ALFLEX 1 FLEX 2
FLEX 1 FLEX 2
PS12
1000
DC
SD SA-6ALFLEX 1 FLEX 2
FLEX 1 FLEX 2
PS12
1000
-18 dBm
-23 dBm
-28 dBm
-34 dBm
-18 dBm
-44 dBm
SDMST616
-34 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST616
-39 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST612
-40 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST606
-40 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST616
-34 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
18 ft RG6 per floor2 floor Tap spacing6 dB ave tap loss4 taps x 6 dB =24 dB Amp Spacing
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
Tap per Alternating Floors, 8 Floor, 26 dB Amp SpacingThe 26 dB amplifier spacing splits the distribution
between the (2) SD SA-6AL amplifi ers which have 30
dB maximum gain.
The AGC output of the SD-SA-6AL amplifi er is updated
to the equivalent of the -1 dBm composite output
(-18dBm peak at 2150 MHz). The fi rst generation SD-SA-6AL were set at -18 dBm @ 2150 MHz.
A minimum IDF input of -40 dBm is budgeted.
SD MST6xx / 2 Floors, SD SA-6AL 28 dB Spacing
MHz/ dB 250 950 1450 2150RG-6 150 ft 5.9 9.6 11.7 14.5
MST616 1.0 1.3 1.4 1.9
MST616 1.0 1.3 1.4 1.9
MST612 1.5 1.8 1.9 2.1
MST606 3.4 3.8 4.5 5.5
TOTAL 12.8 17.8 20.9 25.9
The new SD SA-6AL internal slope compensation off sets
12 dB of the 13 dB slope.
AMPLIFIER SPACING
Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com [email protected]
Revised Aug 23 2012
7
28,29
31
27
25,26
24
22,23
20
FLOOR30
FLOOR21
-45 dBm
DC
SD SA-6ALFLEX 1 FLEX 2
FLEX 1 FLEX 2
PS12
1000
DC
SD SA-6ALFLEX 1 FLEX 2
FLEX 1 FLEX 2
PS12
1000
-18 dBm
-25 dBm
-32 dBm
-18 dBm
-42 dBm
SDMST616
-34 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST612
-37 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST606
-38 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SDMST616
-34 dBm
FLEX 1 FLEX 2
FLEX 1 FLEX 2
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
SWMBOX-xx
15 ft RG6 per floor3 floor Tap spacing8 dB ave tap loss3 taps x 8 dB =24 dB Amp Spacing
Tap per (3) Floors, 9 Floor, 24 dB Amplifi er SpacingThe 24 dB amplifier spacing splits the distribution
between the (2) SD SA-6AL amplifi ers. A minimum IDF
input of -38 dBm is budgeted.
SD MST6xx / 3 Floors, SD SA-6AL 24 dB Spacing
MHz/ dB 250 950 1450 2150RG-6 150 ft 5.9 9.6 11.7 14.5
MST616 1.0 1.3 1.4 1.9
MST612 1.5 1.8 1.9 2.1
MST606 3.4 3.8 4.5 5.5
TOTAL 11.8 16.5 19.5 23.5
The SD SA-6AL internal slope compensation off sets
12 dB of the 12 dB slope.
AMPLIFIER SPACING
Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com [email protected]
Revised Aug 23 2012
8SONORA CONFIDENTIAL
C11
THRU OUT 11
2
1 2
C12
C1
C7
T1
12
1 2
THRU IN 11
2
TAP 1 1
2
R1
R3
R5
C5
12
C9
R7C15
C2
TAP 71
2
C52
THRU IN 71
2
1 2
R27C56
R28
C54
R26
C58
C53
1T 1 2
C51
C49 C50
R25
T7
0.5T 12THRU OUT 7
1
22T 1 2
C57
4T 12
C55
BALUN TYPE, 250 -2150 MHZ, 2 AMP DC
BYPASS TYPE, 2 -2150 MHZ, 2 AMP DC
BALUN TYPE VS BYPASS TAPSSONORA has two ferrite based directional coupler
designs. Both designs allow up to 2 amps of DC to pass
from Output to Input and block DC from the tap port.
The (top) Balun type design is limited to 250 to 2150 MHz
because 2 amps of current will signifi cantly aff ect the
insertion loss in the 2 to 50 MHz range. This design has
the minimal insertion loss at 2150 MHz.
The (bottom) by-pass design blocks the DC from passing
through the balun and bypasses the current through a
separate inductor. This circuit would be recommended
for applications where SMATV signals would be present .
Both models have been developed with samples
available.