3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: [email protected] The E6200 Series magnetic lock is mounted to the underside of the header, on the stop side of the door. P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E6200.vsd REV - 07-10 Page 1 Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email [email protected] INSTALLATION INSTRUCTIONS E6200 SERIES MAGNETIC LOCK Electrical Instructions: Use properly fused U. L. Listed Power Supply Do not install a diode in parallel with any magnetic lock. A diode will cause a delay when releasing the door and residual magnetism to occur. Although SDC recommends the use of a DC power supply, a transformer with an adjacent mounted full wave bridge rectifier may be used. A significant drop will occur when using a full wave bridge rectifier. Any low voltage condition will cause erratic operation of the optional board sensor. When using a full wave bridge rectifier all access controls and/or release contacts must be located between the EMlock and rectifier to ensure quick release. Electrical Specifications: Dual Voltage 12 or 24VDC Power Consumption .250mA@12VDC .125mA@24VDC DS Door Status Sensor SPDT, 500mA@30VDC LS Lock Status Sensor SPDT, 2A@30VDC Mounting Screws Armature Frame Outswing

Upload: jmac-supply

Post on 11-Nov-2015

270 views

Category:

Documents


2 download

DESCRIPTION

Buy the SDC E300 at JMAC Supply.https://www.jmac.com/Security_Door_Controls_E300_p/sdc-e300.htm?=scribd

TRANSCRIPT

  • 3580 Willow Lane, Westlake Village, CA 91361-4921

    (805) 494-0622 Fax: (805) 494-8861

    www.sdcsecurity.com E-mail: [email protected]

    The E6200 Series magnetic lock is mounted to the underside of the header, on the stop side of the door.

    P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E6200.vsd REV - 07-10 Page 1

    Any suggestions or comments to this instruction or

    product are welcome. Please contact us through

    our website or email [email protected]

    INSTALLATION INSTRUCTIONS

    E6200 SERIES MAGNETIC LOCK

    Electrical Instructions:

    Use properly fused U. L. Listed Power Supply

    Do not install a diode in parallel with any magnetic lock. A diode

    will cause a delay when releasing the door and residual magnetism

    to occur.

    Although SDC recommends the use of a DC power supply, a

    transformer with an adjacent mounted full wave bridge rectifier

    may be used. A significant drop will occur when using a full wave

    bridge rectifier.

    Any low voltage condition will cause erratic operation of the

    optional board sensor.

    When using a full wave bridge rectifier all access controls and/or

    release contacts must be located between the EMlock and rectifier

    to ensure quick release.

    Electrical Specifications:

    Dual Voltage 12 or 24VDC

    Power Consumption .250mA@12VDC

    .125mA@24VDC

    DS Door Status Sensor SPDT, 500mA@30VDC

    LS Lock Status Sensor SPDT, 2A@30VDC

    Mounting Screws

    Armature

    Frame

    Outswing

  • P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E6200.vsd REV - 07-10 Page 2

    1. Fold template as indicated on dotted line. For single doors locate template against the door and header on the

    lock jamb side of the frame.

    2. Mark and drill holes as indicated by the template.

    3. Mount armature to door.

    STEPS 1 & 2

    STEP 3

    N/C

    N/O

    COM

    YEL

    GRN

    ORG

    COMMON

    GOOD BOND

    NO/POOR BOND

    WIRE

    COLORCONTACT DESCRIPTION

    BOND SENSOR (BAS) WIRING

    To Properly

    Fused DC Power

    source (-)

    (+)* ACCESS CONTROL(S)

    E6200 EMLOCKBLUBLKBRN

    RED(+)

    (-)

    24VDC @ .125 Amps

    To Properly

    Fused DC Power

    source (-)

    (+)* ACCESS CONTROL(S)

    E6200 EMLOCKBLU

    BRNBLK

    RED(+)

    (-)

    12VDC @ .250 Amps

    24VDC CONFIGURATION

    12VDC CONFIGURATION

    N/C

    N/O

    COM

    WHT

    GRY

    VIO

    COMMON

    ACTIVATE WHEN DOOR

    OPEN

    ACTIVATE WHEN DOOR

    CLOSED

    WIRE

    COLORCONTACT DESCRIPTION

    DOOR POSITION SENSOR (DPS) WIRING

    4. WIRING DETAILS:

  • P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E6200.vsd REV - 07-10 Page 3

    5. Install magnet onto the header with the magnetic face towards the door side of the stop.

    Assure that the magnet and armature line up properly, then tighten down ALL mounting screws.

    STEP 5

    6. Test operation. When all is operating properly, install anti-

    tamper plugs over socket head screws using a soft hammer

    to avoid damage to the housing.

  • P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E6200.vsd REV - 07-10 Page 4

    7.20

    (182.88)

    .375

    (9.525)

    4.00

    (101.60)

    MODEL E6200

    #1/4-20 x 2

    .50

    (12.70)

    .75

    (19.05) 1.84

    (46.74) 2.875

    (73.03)

    2.25

    (67.15)

    2.25

    (67.15)

    6.00

    (152.40)

    2.75

    (69.85).64

    (16.26)

    8.00

    (203.20)

    1.00

    (25.40)

    CL

  • 801 Avenida Acaso, Camarillo, Ca. 93012

    (805) 494-0622 Fax: (805) 494-8861

    www.sdcsecurity.com E-mail: [email protected]

    P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd REV A1 04-11 Page 1

    Any suggestions or comments to this instruction or

    product are welcome. Please contact us through

    our website or email [email protected]

    INSTALLATION INSTRUCTIONS

    E1200 SERIES MAGNETIC LOCK

    Electrical Instructions:

    Use properly fused U. L. Listed Power Supply

    Do not install a diode in parallel with any magnetic lock. A diode

    will cause a delay when releasing the door and residual magnetism

    to occur.

    Although SDC recommends the use of a DC power supply, a

    transformer with an adjacent mounted full wave bridge rectifier

    may be used. A significant drop will occur when using a full wave

    bridge rectifier.

    Any low voltage condition will cause erratic operation of the

    optional board sensor.

    When using a full wave bridge rectifier all access controls and/or

    release contacts must be located between the EMlock and rectifier

    to ensure quick release.

    Electrical Specifications:

    Dual Voltage 12 or 24VDC

    Power Consumption .500mA@12VDC

    250mA@24VDC

    DS Door Status Sensor SPDT, 500mA@30VDC

    LS Lock Status Sensor SPDT, 2A@30VDC

    Outswing

    Quick Mount

    Interlocking

    Mounting Assembly

    Mounting Screws

    Armature

    Interlocking

    Mounting Plate

    Frame

  • P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd REV A1 04-11 Page 2

    1. Inspect the frame header to determine if mounting accessories are required (refer to page 4).

    2. Fold template as indicated on dotted line. For single doors locate template against the door and header on the

    lock jamb side of the frame.

    3. Mark and drill holes as indicated by the template.

    4. Mount armature to door.

    STEP 4

    STEPS 2 & 3

    5. Install magnet onto the header with the magnetic stripes towards the door side of the stop.

    Assure that the magnet and armature line up properly, then tighten down ALL mounting screws.

    STEP 5

    HOLLOW METAL DOOR

    From Sexnut side of door, drill exactly 1/2 hole thru one metal

    thickness only. From Armature side of door, drill 5/8 hole to insert

    reinforcement tube. Press in sexnut and reinforcement tube all the

    way and mount armature to door using hardware provided.

    REINFORCEMENT

    TUBE1-3/4 HOLLOWMETAL DOOR

    5/8 DRILL

    STEEL WASHER 2X

    RUBBER WASHER

    5/16-18 SOC HD

    SCREW

    WITH 3/16 (5MM) ALLEN HEX

    ARMATURE1/2 DRILL

    SEXNUT

  • P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd REV A1 04-11 Page 3

    6. Holding the magnet housing at each end, engage the entire length of the interlock detail, by pushing towards the

    door. Tap with a soft hammer to ensure proper alignment and engagement.

    CAUTION: The lock body must be held in place until secured with mounting screws. Secure socket head

    screws provided inside the housing at each end. Start screws into threads carefully to avoid stripping the

    threads. Check alignment and tighten screws. Pull wires through frame, mounting plate and magnet housing

    STEP 6

    7. Select jumper position for 12VDC or 24VDC. Connect power to magnetic lock.

    A/C

    MAINS

    POWER

    SUPPLY

    12VDC

    or

    24VDC

    SWITCH or

    ACCESS

    CONTROL

    +

    -

    8. Test operation. When all is operating properly, tighten

    all screws as shown. Install security pins and screws

    as shown. Install anti-tamper plugs over socket head

    screws using a soft hammer to avoid damage to the housing.

    ATTACH THE RED SIDE OF THE CONNECTOR HERE

    FOR A GREEN LED ENERGIZED & SECURE (RED=ENERGIZED & UNSECURE)

    ATTACH THE GREEN SIDE OF THE CONNECTOR HERE

    FOR A RED LED ENERGIZED AND UNSECURE (GREEN=ENERGIZED & SECURE)

    COMNC

    NO

    Door Position Sensor (Reed switch)

    RED (open with door closed)

    GREEN (closed with door closed)

    BLACK

    RGBW

    GBR

    Door

    Position

    Sensor

    Lock

    Status

    Switch

    (Relay)

    Power

    Supply

    Voltage Jumper

    8NC

    7C

    6NO

    5NC4C

    3NO

    2-

    1+

    12VDC 24VDC

    LEDRED

    GRN

  • P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd REV A1 04-11 Page 4

    To maintain surface plating from corrosion:Do not touch the lock face with your hands.

    Clean lock face with Scotch-Brite pad by 3M (do not use

    sandpaper).

    Apply a thin film of rust inhibitor (LPS-3) on lock face.

    Repeat application on armature plate.

    Supplied Mounting Hardware

    ANGLE BRACKET

    E12L

    Inches: 10.5" L x 0.5" H x 0.75" D

    mm: 266 L x 12.7 H x 19 D

    ADJUSTABLE ANGLE BRACKET

    E12A

    For use with Model E1200 Series

    STOP FILLER PLATE

    EF02

    Inches: 10.5" L x 0.5" H x 0.75" D

    mm: 266 L x 12.7 H x 19 D

    GLASS DOOR ARMATURE BRACKET

    E12U

    For use with Model E600 Series

    Field adjustable for glass thickness

    TOP JAMB MOUNTING BRACKET

    E12Z

    For use with Model E1200 Series

    MOUNTING ACCESSORIES:

  • 801 Avenida Acaso, Camarillo, Ca. 93012

    (805) 494-0622 Fax: (805) 494-8861

    www.sdcsecurity.com E-mail: [email protected]

    The E600 Series magnetic lock is mounted to the underside of the header, on the stop side of the

    door. An inswing mounting kit (optional) can be used when mounting on the hinge side of the

    door.

    P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E600.vsd REV A1 04-11 Page 1

    Any suggestions or comments to this instruction or

    product are welcome. Please contact us through

    our website or email [email protected]

    INSTALLATION INSTRUCTIONS

    E600 SERIES MAGNETIC LOCK

    Outswing

    Electrical Instructions:

    Use properly fused U. L. Listed Power Supply

    Do not install a diode in parallel with any magnetic lock. A diode

    will cause a delay when releasing the door and residual magnetism

    to occur.

    Although SDC recommends the use of a DC power supply, a

    transformer with an adjacent mounted full wave bridge rectifier

    may be used. A significant drop will occur when using a full wave

    bridge rectifier.

    Any low voltage condition will cause erratic operation of the

    optional board sensor.

    When using a full wave bridge rectifier all access controls and/or

    release contacts must be located between the magnetic lock and rectifier

    to ensure quick release.

    Electrical Specifications:

    Dual Voltage 12 or 24VDC

    Power Consumption 500mA@12VDC

    250mA@24VDC

    DS Door Status Sensor SPDT, 500mA@30VDC

    LS Lock Status Sensor SPDT, 2A@30VDC

    Quick Mount

    Interlocking

    Mounting Assembly

    Mounting Screws

    Armature

    Interlocking

    Mounting Plate

    Frame

  • P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E600.vsd REV A1 04-11 Page 2

    1. Inspect the frame header to determine if mounting accessories are required (refer to page 4).

    2. Fold template as indicated on dotted line. For single doors locate template against the door and header on the

    lock jamb side of the frame.

    3. Mark and drill holes as indicated by the template.

    4. Mount armature to door.

    STEP 4

    STEPS 2 & 3

    STEP 5

    5. Install mounting plate to header with the interlock detail away from the door side of the stop.

    Loosely fasten screws through adjustment slot as shown. Assure that the mounting plate and

    armature line up properly, then tighten down ALL mounting screws.

    HOLLOW METAL DOOR

    From Sexnut side of door, drill exactly 1/2 hole thru one metal

    thickness only. From Armature side of door, drill 5/8 hole to insert

    reinforcement tube. Press in sexnut and reinforcement tube all the

    way and mount armature to door using hardware provided.

    REINFORCEMENTTUBE

    1-3/4 HOLLOW

    METAL DOOR

    5/8 DRILL

    STEEL WASHER 2X

    RUBBER WASHER

    5/16-18 SOC HD

    SCREW

    WITH 3/16 (5MM)

    ALLEN HEX

    ARMATURE1/2 DRILL

    SEXNUT

  • P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E600.vsd REV A1 04-11 Page 3

    7. Select jumper position for 12VDC or 24VDC. Connect power to magnetic lock.

    STEP 6

    A/C

    MAINS

    POWER

    SUPPLY

    12VDC

    or

    24VDC

    +

    -SWITCH or ACCESS CONTROL

    8. Test operation. When all is operating properly, tighten

    all screws as shown. Install anti-tamper plugs over socket head

    screws using a soft hammer to avoid damage to the housing.

    6. Holding the magnet housing at each end, engage the entire length of the interlock detail, by pushing towards the

    door. Tap with a soft hammer to ensure proper alignment and engagement.

    CAUTION: The lock body must be held in place until secured with mounting screws. Secure socket head

    screws provided inside the housing at each end. Start screws into threads carefully to avoid stripping the

    threads. Check alignment and tighten screws. Pull wires through frame, mounting plate and magnet housing

    COMNC

    NO

    Door Position Sensor (Reed switch)

    RED (open with door closed)

    GREEN (closed with door closed)BLACK

    +-NO

    CNC

    12

    34

    5

    Power

    Supply Lock Status

    Switch

    Voltage Jumper 12VDC24VDC

    A RED LED INDICATES

    ENERGIZED & UNSECURED

    (GREEN=ENERGIZED & SECURE)

    LED

  • P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E600.vsd REV A1 04-11 Page 4

    To maintain surface plating from corrosion:Do not touch the lock face with your hands.

    Clean lock face with Scotch-Brite pad by 3M (do not use sandpaper).

    Apply a thin film of rust inhibitor (LPS-3) on lock face.

    Repeat application on armature plate.

    Supplied Mounting Hardware

    ANGLE BRACKET

    E12L

    Inches: 10.5" L x 0.5" H x 0.75" D

    mm: 266 L x 12.7 H x 19 D

    May be field cut for use with E600

    ADJUSTABLE ANGLE BRACKET

    E6A

    For use with Model E600 Series

    STOP FILLER PLATE

    EF02

    Inches: 10.5" L x 0.5" H x 0.75" D

    mm: 266 L x 12.7 H x 19 D

    May be field cut for use with E600

    GLASS DOOR ARMATURE BRACKET

    E6U

    For use with Model E600 Series

    Field adjustable for glass thickness

    TOP JAMB MOUNTING BRACKET

    E6Z

    For use with Model E600 Series

    MOUNTING ACCESSORIES:

  • The E300 Series magnetic lock is mounted to the underside of the cabinet housing

    or vertically inside the cabinet.

    P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E300.vsd REV A 04-11 Page 1

    Any suggestions or comments to this instruction or

    product are welcome. Please contact us through

    our website or email [email protected]

    INSTALLATION INSTRUCTIONS

    E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK

    Electrical Specifications:

    Dual Voltage 12 or 24VDC

    Power Consumption 360mA@12VDC

    180mA@24VDC

    LS Lock Status Sensor SPDT, 250mA@30VDC

    801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622

    www.sdcsecurity.com E-mail: [email protected]

    Select jumper position for 12VDC or 24VDC. Connect power to magnetic lock.

    A/C

    MAINS

    POWER

    SUPPLY

    12VDC

    or

    24VDC

    +

    -SWITCH or ACCESS CONTROL

    Test operation. After verifying proper operation, tighten

    all screws as shown. Install anti-tamper plugs over socket

    screws using a soft hammer to avoid damage to the housing.

    +-

    12

    Power

    Supply

    Voltage Jumper 12VDC24VDC

    COMNC

    NO

    Lock Status Switch

    RED (open with power and door closed)

    GREEN (closed with power and door closed)BLACK

  • P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E300.vsd REV A 04-11 Page 2

    STEP 2MOUNT THE ARMATURE PLATE TO DOOR USING (1 )

    RUBBER WASHER SANDWICHED BETWEEN (2)

    STEEL WASHERS (THE RUBBER WASHER AND (2)

    STEEL WASHERS ARE INSTALLED ON THE

    MOUNTING BOLT BETWEEN THE ARMATURE PLATE

    AND DOOR).

    DRILL HOLES AS INDICATED

    ON TEMPLATE.

    PLACE TEMPLATE AGAINST

    CABINET DOOR AND FRAME.

    STEP 1FOLD TEMPLATE ALONG

    DOTTED LINE.

    STEP 3INSTALL THE MOUNTING PLATE

    ADJUST THE MOUNTING PLATE SO THAT IT AND

    THE ARMATURE FORM A RIGHT ANGLE.

    INSTALL THE REMAINING MOUNTING SCREWS.

    STEP 4INSTALL MAGNET TO

    MOUNTING PLATE.

    CAUTION: The lock body must be held in place until secured with mounting screws. Secure socket head

    screws provided inside the housing at each end. Start screws into threads carefully to avoid stripping the

    threads. Check alignment and tighten screws. Pull wires through frame, mounting plate and magnet housing