Sealed System Symptoms 2010. Sandeep Gupta RTC HA North Videocon. REFRIGERATOR NOT COOLING. NOT COOLING. COMPRESSOR DEFECTS. SEALED SYSTEM DEFECTS. ELECTRICAL. MECHANICAL. RUNNING BUT NOT COOLING. GROUND. NOISE. GAS LEAK. WINDING OPEN. CHOKE. STARTING NOISE. RUNING WINDING OPEN. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Sealed System Symptoms 2010

Sealed System Symptoms2010

Sealed System Symptoms2010

Sandeep Gupta RTC HA North Videocon

Sandeep Gupta RTC HA North Videocon

Page 2: Sealed System Symptoms 2010

REFRIGERATOR NOT COOLING

GROUND

RUNING WINDING OPEN

STARTING WINDING OPEN

WINDING OPEN

ANY WINDINGR OR S

BOTH WINDINGR & S

INTERNAL SHORT

MORE CURRENT

WINDING INSULATION RESISTANCE LOW

ELECTRICAL

STARTING NOISE

RUNNING NOISE

STOPPING NOISE

NOISE

POOR PUMPING

NOT PUMPING

JAMMED WHEN HOT

MECHANICAL

COMPRESSOR DEFECTS

GAS LEAK

CAPILLARY CHOKE

DRIER CHOKE

CHOKE

NOT PUMPING

RUNNING BUT NOT COOLING

OVER CHARGE

OIL TROUBLE

MOISTURE TROUBLE

PARTIAL CHOKE

SHORTAGE OF GAS

POOR PUMPING

LESS COOLING

SEALED SYSTEM DEFECTS

NOT COOLING

Page 3: Sealed System Symptoms 2010

LOW PRESSURE VAPOUR

LOW PRESSURE LIQUID HIGH PRESSURE VAPOUR

HIGH PRESSURE LIQUID

EVAPORATOR - FULLY FROSTED {COLD }

SUCTION PRESSURE - NORMAL

SUCTION LINE - SLIGHTLY BELOW ROOM

TEMP.

DISCHARGE PRESSURE - NORMAL

CONDENSER - HOT

CAPILLARY TUBE - WARM

COMPRESSOR DISCHARGE - VERY HOT

WATTAGE - RATED

CURRENT - NORMAL / RATED

EVAPORATORCONDENSER

DRIER

CAPILLARY

NORMAL SEALED SYSTEM

140 -150 psig.

5-7 psig.

PRESSURES SHOWN ARE AT NORMAL AMBIENT TEMP. OF 32 C

Page 4: Sealed System Symptoms 2010

OVER CHARGED SEALED SYSTEM

EVAPORATORCONDENSER

DRIER

CAPILLARY

150 -170 psig.

10-15 psig.

LOW PRESSURE VAPOUR

LOW PRESSURE LIQUID HIGH PRESSURE VAPOUR

HIGH PRESSURE LIQUID

PRESSURES SHOWN ARE AT NORMAL AMBIENT TEMP. OF 32 C

EVAPORATOR - FULLY FROSTED {COLD}

SUCTION PRESSURE - HIGHER THAN NORMAL

SUCTION LINE - VERY COLD

OR MAY FROST HEAVILY

DISCHARGE PRESSURE - NORMAL

OR SLIGHTLY HIGHER

CONDENSER - HOT

CAPILLARY TUBE - COOL

COMPRESSOR DISCHARGE - VERY HOT

WATTAGE > RATED

CURRENT > NORMAL / RATED

Page 5: Sealed System Symptoms 2010

EVAPORATOR - PARTIALLY FROSTED

{EXTREMLY COLD NEARINLET}

OUTLET BELOW ROOM TEMP.

SUCTION PRESSURE - LOWER THAN

NORMAL

SUCTION LINE - WARM / ROOM TEMP.

DISCHARGE PRESSURE < NORMAL

CONDENSER - WARM

CAPILLARY TUBE - WARM

COMPRESSOR DISCHARGE - HOT

WATTAGE < RATED

CURRENT < NORMAL / RATED

UNDER CHARGED SEALED SYSTEM

EVAPORATOR CONDENSER

DRIER

CAPILLARY130 psig.

At / bellow 0 psig.

LOW PRESSURE VAPOUR

LOW PRESSURE LIQUID HIGH PRESSURE VAPOUR

HIGH PRESSURE LIQUID

PRESSURES SHOWN ARE AT NORMAL AMBIENT TEMP. OF 32 C

Page 6: Sealed System Symptoms 2010

COMPRESSOR POOR PUMPING

130-140 psig.

10 -15 psig.

LOW PRESSURE VAPOUR

LOW PRESSURE LIQUID HIGH PRESSURE VAPOUR

HIGH PRESSURE LIQUID

PRESSURES SHOWN ARE AT NORMAL AMBIENT TEMP. OF 32 C

EVAPORATOR

CONDENSER

DRIER

CAPILLARY

EVAPORATOR - MAY BE FULLY FROSTED

{ COLD - BUT NOT SUFFICIENT}

SUCTION PRESSURE - SLIGHTLY

ABOVE NORMAL

SUCTION LINE - AT ROOM TEMP.

DISCHARGE PRESSURE - LESS THAN

NORMAL

CONDENSER - HOT [LESS INTENCITY]

CAPILLARY TUBE - WARM

COMPRESSOR DISCHARGE - HOT

WATTAGE < RATED

CURRENT < NORMAL / RATED

Page 7: Sealed System Symptoms 2010

EVAPORATOR -NO FROST

SUCTION PRESSURE - ABOVE

NORMAL

SUCTION LINE -AT ROOM TEMP.

DISCHARGE PRESSURE - LESS

THAN NORMAL

CONDENSER - AT ROOM TEMP.

CAPILLARY TUBE - AT ROOM TEMP.

COMPRESSOR DISCHARGE - AT

ROOM TEMP.

WATTAGE < RATED

EVAPORATOR

CONDENSER

DRIER

CAPILLARY

COMPRESSOR NOT PUMPING

40-50 psig.

40-50 psig.

LOW PRESSURE VAPOUR

LOW PRESSURE LIQUID HIGH PRESSURE VAPOUR

HIGH PRESSURE LIQUID

PRESSURES SHOWN ARE AT NORMAL AMBIENT TEMP. OF 32 C

Page 8: Sealed System Symptoms 2010

EVAPORATOR - NO FROST

SUCTION PRESSURE - NEAR ZERO PSIG

SUCTION LINE - ROOM TEMP.

DISCHARGE PRESSURE - NEAR ZERO

PSIG

CONDENSER - ROOM TEMP.

CAPILLARY TUBE - ROOM TEMP.

COMPRESSOR DISCHARGE - ROOM

TEMP.

WATTAGE < NORMAL

CURRENT < NORMAL / RATED IF CHOKE

AT ANY POIN & MOTOR RUN

CONTINIOUSLY,

GAS LEAKED SEALED SYSTEM

EVAPORATORCONDENSER

DRIER

CAPILLARY

>0 psig.(Ambient)

<0 psig. (Ambient)

LOW PRESSURE VAPOUR

LOW PRESSURE LIQUID HIGH PRESSURE VAPOUR

HIGH PRESSURE LIQUID

PRESSURES SHOWN ARE AT NORMAL AMBIENT TEMP. OF 32 C

Page 9: Sealed System Symptoms 2010

EVAPORATOR - NO FROST

SUCTION PRESSURE - DEEP VACUUM

SUCTION LINE - ROOM TEMP.

DISCHARGE PRESSURE -LESS THAN

NORMAL

CONDENSER - INITIALLY HOT THEN DROPS

TO ROOM TEMP

CAPILLARY TUBE - ROOM TEMP.

COMPRESSOR DISCHARGE - ROOM TEMP.

WATTAGE < NORMAL

CURRENT < NORMAL / RATED IF CHOKE AT

ANY POINT & MOTOR RUNS CONTINIOUSLY OR

CURRENT > NORMAL / RATED IF CHOKE

ON DISCHARGE TUBE & MOTOR MAY TRIP.

COMPLETELY RESTRICTED SEALED SYSTEM

EVAPORATORCONDENSER

DRIER

CAPILLARY

80-90 psig.@ =60%NORMAL

20”-25” vacuum.

LOW PRESSURE VAPOUR

LOW PRESSURE LIQUID HIGH PRESSURE VAPOUR

HIGH PRESSURE LIQUID

PRESSURES SHOWN ARE AT NORMAL AMBIENT TEMP. OF 32 C

Page 10: Sealed System Symptoms 2010

PARTIALLY RESTRICTED SEALED SYSTEM

EVAPORATOR CONDENSER

DRIER

CAPILLARY

90-100 psig.

5” - 20” vac

LOW PRESSURE VAPOUR

LOW PRESSURE LIQUID HIGH PRESSURE VAPOUR

HIGH PRESSURE LIQUID

PRESSURES SHOWN ARE AT NORMAL AMBIENT TEMP. OF 32 C

EVAPORATOR - PARTIALLY FROSTED

{EXTREMLY COLD NEARINLET}

OUTLET BELOW ROOM TEMP.

SUCTION PRESSURE < NORMAL/ IN

VACUUM

SUCTION LINE - WARM / ROOM TEMP.

DISCHARGE PRESSURE < NORMAL

CAPILLARY TUBE - AT ROOM TEMP. /

COLDER.

CONDENSER - TOP COILS VERY HOT LOWER

COILS AT ROOM TEMP / BELOW ROOM TEMP.

COMPRESSOR DISCHARGE - VERY HOT

WATTAGE < RATED

CURRENT < NORMAL / RATED

Page 11: Sealed System Symptoms 2010

EVAPORATOR - FULLY FROSTED

{PATCHES OF ICE FORMATION}

SUCTION PRESSURE -SLIGHTLY

ABOVE NORMAL

SUCTION LINE - HIGHER THAN ROOM

TEMP.

DISCHARGE PRESSURE - SLIGHTLY

ABOVE NORMAL.

CONDENSER - HOT

CAPILLARY TUBE - WARM

COMPRESSOR DISCHARGE - VERY HOT

WATTAGE > RATED

CURRENT > NORMAL / RATED

EVAPORATORCONDENSER

DRIER

CAPILLARY

OIL TROUBLE

150 -160 psig.

5 -10 psig.

LOW PRESSURE VAPOUR

LOW PRESSURE LIQUID HIGH PRESSURE VAPOUR

HIGH PRESSURE LIQUID

PRESSURES SHOWN ARE AT NORMAL AMBIENT TEMP. OF 32 C

Page 12: Sealed System Symptoms 2010

EVAPORATORCONDENSER

DRIER

CAPILLARY

140-150 psig.

5-7 psig.

SEALED SYSTEM RESTRICTED WITH MOISTURE

80-90 psig.

20”-25” vac.

90-100 psig.

5” - 18” VACUUM

EVAPORATOR - NO FROST { OR INTERMITANT

FROST}

SUCTION PRESSURE - DEEP VACUUM

SUCTION LINE - ROOM TEMP.

DISCHARGE PRESSURE -LESS THAN NORMAL

CONDENSER - ROOM TEMP.

CAPILLARY TUBE - ROOM TEMP.

COMPRESSOR DISCHARGE - ROOM TEMP.

WATTAGE > RATED

CURRENT > NORMAL / RATED

LOW PRESSURE VAPOUR

LOW PRESSURE LIQUID HIGH PRESSURE VAPOUR

HIGH PRESSURE LIQUID

When any moisture reaches to capillary tube's mouth gets

freeze up there after the system behaves like choke till it

melts move ahead

PRESSURES SHOWN ARE AT NORMAL AMBIENT TEMP. OF 32 C