seam quality

11
SEAM WELDING viraj engg.

Upload: suraj-ahire

Post on 19-Feb-2017

60 views

Category:

Engineering


2 download

TRANSCRIPT

Page 1: Seam quality

SEAM WELDING

viraj engg.

Page 2: Seam quality

Seam welding :

. Resistance seam welding is a variant of the basic

resistance spot welding process. In spot welding a weld nugget is produced by passing an electric current through the sheet materials to be welded while they are held together under a mechanical force between shaped copper electrodes in a lap configuration.

Page 3: Seam quality

Machine make : JAYA HIND SCIAKY LIMITEDM/C Type : Circumferential Seam Welding machineControl : ForwelCylender Bore Dia : 100mmKVA at 50%duty cycle : 150

Page 4: Seam quality

Sample tank taken : Fuel tankMaterial of tank : CRCAMaterial Thickness : 0.8 mm

Page 5: Seam quality

Seam welding Quality check1) Follow the recommended practice as

per Instruction manual of jaya hind sciaky limited.

2) Visual inspection a) Straightness of seam welding.3) Test to insure the quality of seam. a) Tear down test . b) pillow test.

Page 6: Seam quality

1) Follow the recommended practice as per Instruction manual of jaya hind sciaky limited.

Page 7: Seam quality

1 2 3 4 5 6 7 8 9 10

25mm

Referring instruction manual as shown above for this case of 0.8 mm thickens sheet material we are considering 10 nose of nuggets in 25 mm length.

Page 8: Seam quality

We are optimized the acceptable seam welding quality by controlling the following parameter : 1. Welding current. 2. Electrode force. 3. Squeeze, Heat and cool timings. 4. Welding speed.

Page 9: Seam quality

1) Visual inspection We are insuring the straightness of seam

welding end cover and longitudinal seam welding.

Page 10: Seam quality

3) Test to insure the quality of seam. a) Tear down test : By setting correct parameter

we go for tear test . One sheet is clamp to the vise jaw and other sheet is pulled.

Page 11: Seam quality

B) Pillow test : Two square sheet of 0.8mm is seam weld along the edge with adapter at center . Then air at pr. Of 0.3 kg/cm 2. is filled into the sheet through adapter result into the swelling of sheet , Then go for leakage test.