Return to Contents High Voltage Joints & Terminations. Joints: • EHVS: Inline Joints - Heat Shrinkable - Polymeric Cables - up to 72kV Inline Joints - Heat Shrinkable - Polymeric Cables - up to 72kV - Selection Guide • EHVS: Inline Splice Break Joint - Polymeric Cables - 123kV up to 170kV Terminations: • IHVT/OHVT: Termination - Heat Shrinkable - Polymeric Cables - up to 72kV Termination - Heat Shrinkable - Polymeric Cables - up to 72kV - Selection Guide • OHVT: Termination - Outdoor Compact Dry Type - Polymeric Cables - 72kV up to 145kV • OHVT: Termination - Outdoor Composite Type - Polymeric Cables - 123kV up to 170kV • PHVS: Termination - Compact for Gas Insulated Switchgear - up to 145kV • S(T)HVT: Termination - Switch Gear and Transformer - 123kV up to 170kV Accessories: • EPPA-055: High Voltage Link Box - for Cross Bonding and Sectionalising • EPPA: Mechanical Connectors for High Voltage - Joints and Terminations Section 9: Energy Division http://energy.tycoelectronics.com

Upload: doankien

Post on 24-Apr-2018

226 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

Return to Contents

High Voltage Joints &Terminations.

Joints:• EHVS:

Inline Joints - Heat Shrinkable - Polymeric Cables - up to 72kV

Inline Joints - Heat Shrinkable - Polymeric Cables - up to 72kV - Selection Guide

• EHVS:Inline Splice Break Joint - Polymeric Cables - 123kV up to 170kV

Terminations: • IHVT/OHVT:

Termination - Heat Shrinkable - Polymeric Cables - up to 72kV

Termination - Heat Shrinkable - Polymeric Cables - up to 72kV - Selection Guide

• OHVT:Termination - Outdoor Compact Dry Type - Polymeric Cables - 72kV up to 145kV

• OHVT:Termination - Outdoor Composite Type - Polymeric Cables - 123kV up to 170kV

• PHVS:Termination - Compact for Gas Insulated Switchgear - up to 145kV

• S(T)HVT:Termination - Switch Gear and Transformer - 123kV up to 170kV

Accessories: • EPPA-055:

High Voltage Link Box - for Cross Bonding and Sectionalising

• EPPA:Mechanical Connectors for High Voltage - Joints and Terminations

Section 9:

Energy Divisionhttp://energy.tycoelectronics.com

Page 2: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

http://energy.tycoelectronics.comEnergy Division

Joints for Polymeric Insulated Cables 72 kV

The elastomeric Raychem 72 kVjoints are suitable for all polymericcables and can accommodate variouscross-bonding shield break andexternal grounding arrangements.

• Quick cable preparationNo need for insulation sanding or pencilling

• Simplified installationNo specialists required. A qualifiedmedium-voltage jointer will betrained in one day.

• Pre-engineered wall thicknessAll product dimensions are set andchecked at the factory before theproduct is shipped to the field.

• Time savingsDue to short installation time out-ages are kept to a minimum inrepair situations.

• High reliabilityThe combination of long experienceand rigorous testing to internationalstandards leads to high joint relia-bility.

R

EPP0341 03.09.2002 11:21 Uhr Seite 5

Page 3: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

Joints for Polymeric Insulated Cables 72 kV

Designed for easy jointingThe Raychem joint design comprisesof a connector that allows even largecross-sections to be jointed and twodual-wall, heat-shrinkable sleeves. A heavy-walled co-extrusion of twolayers of red insulation forms theinner sleeve. The outer sleeve con-sists of a thick layer of red insulationco-extruded under a black outer con-ductive layer which acts as the jointscreen.

Controlled-torque connectorThe connector design allows cablesto be jointed without special tools,heat treatment or filing off afterinstallation. Shear-head bolts ensurea pre-engineered electrical connec-tion. In developing this new connec-tor, much effort was devoted to simplifying the installation steps.Consequently, the key reliability features are engineered into the connector, before it leaves the factory. The outside surface isalready machined smooth. Theshear-head bolts break off at a pre-determined level below the outersurface of the connector, at adefined torque. This ensures the correct contact pressure is reachedevery time. Oxide-breaking and corrosion prevention is performedby the contact grease inside the connector body. The stable voltagedrop provided by this concept hasbeen demonstrated in field installa-tions which closely follow the predictions of long-term load-cyclingtests.Comprehensive qualification procedures like IEC 61238-1996 andANSI 119.4 1993 prove the excellentlong-term performance.

This is the kit …The set of pre-engineered compo-nents and the Raychem connectorrequire no special installation tools.After placing the heat-shrinkablecomponents over the cable end, theconnector is installed by tighteningthe special bolts, which shear offcleanly when the correct contactforce is reached. Each sleeve in turnis placed over the connector areaand shrunk down. Copper shieldingmesh and an adhesive-coated outersleeve for water sealing then com-plete the joint.

Electrical stress controlA material with stress adjustingcharacteristics is applied onto theconnector and cable screen ends.This heat-shrinkable sleeve incor-porates a conductive coating in the connector area which equalizespotential in the manner of a Faradaycage. It extends over the dielectric to accommodate possible insulationshrink-back.

EPP0341 03.09.2002 11:33 Uhr Seite 2

Page 4: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

Elastomeric TechnologyTwo dual-wall, heat-shrinkable elastomeric sleeves are at the heartof the joint. Because of the uniqueelastromeric technology used intheir manufacture, these dual-wallsleeves shrink rapidly and deliverpre-engineered, uniform layers ofthick insulation. In each case theouter wall of the co-extruded sleeveis heat-shrinkable, while the innerlayer is an elastomer held out in anexpanded form by the bond to theouter layer. Application of heat tothe outer wall causes it to shrink to a pre-determined diameter andsimultaneously allows the innerlayer to contract, conforming tightlyto the joint.In two short steps the installerapplies the required insulation thickness and joint screen. When the cable is in service the rubber-likecharacteristics of the insulation allowthe joint to conform to the dimensio-nal changes of the cable insulationduring load cycling.

Cross-bonding/shield breakThe use of heat-shrinkable sleevesfor stress control, insulation, andscreening provides a location for theshield break at the end of the joint. A mastic installed under the heat-shrinkable outer sleeve ensures highdielectric strength at this point. Thecross-bond can be made withoutinfluencing the electrical field in thejoint, and does not require any special additional components.Requirements according to IEEE # 575are fulfilled.

Outer sealingThe cable oversheath is replacedwith a thick-wall heat-shrinkableinsulating sleeve, which provides the required dielectric strength andis internally coated with a hot-meltadhesive. The heat of installationcauses the adhesive to melt andflow to create an effective water seal and corrosion protection.Grounding leads are sealed by an adhesive coated clip.

EPP0341 03.09.2002 11:34 Uhr Seite 3

Page 5: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

Technical data

Cable insulation diameter range 34–78 mm (1.3''–3.1'') 4 sizes

Space required for assembly 2 m (7 feet)

Max. voltage to ground 40 kV

Basic impulse level 350 kV

Max. continuous conductor 90 °Coperating temperature

Max. conductor emergency temperature 130 °C

1 sec. short circuit temperature 250 °C

The joint has been subjected to tests in accordance to international standardse.g. IEEE 404 1993, EDF HN-68-S-20, SEN 24 1434, ESI 09-16, IEC 840.

Qualification tests by KEMA (according to KEMA S10) and by Raychem(according to PPS 3015) are available on request.

Joints for Polymeric Insulated Cables 72 kV

Stripping tool for XLPE cable:Raychem's stripping tool, designedto remove both semi-conductivescreen and dielectric, will help pro-fessional jointers to overcome thisdifficulty.

© T

yco

Ele

ctro

nic

s E

PP

034

1 9/

02

Tyco Electronics Raychem GmbH, Energy DivisionFinsinger Feld 1, 85521 Ottobrunn/Munich, GermanyPhone: ++49-89-6089-0, Fax: ++49-89-6096345

Energy Division – a pioneer in the development of economical solutions forthe electrical power industry. Our product range includes: Cable accessories, connectors & fittings, electrical equipment, instruments, lighting, insulators &insulation enhancement and surge arresters.

For more information and your country contact person, please visit us at: http://energy.tycoelectronics.com

All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable.Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particularquality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forthin our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, Bowthorpe EMP, Dorman Smith, Dulmison, Hellstern, La Prairie, Morlynn, Raychem, and SIMEL are trademarks.

EPP0341 03.09.2002 11:34 Uhr Seite 4

Page 6: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base
Page 7: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base
Page 8: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base
Page 9: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base
Page 10: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base
Page 11: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base
Page 12: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS

Application

The joint is a pre-fabricated three-piece design for voltage classes up to 170kV. Polymer-insulated cables ofvarious designs can be adopted withrespect to shielding and metal sheath.Cross sections up to 2500 mm2 areapplicable.

Features

• Pre-fabricated three-piece splice design

• Using torque-controlled conductor sleeves

• Short cut-back dimensions

• Integrated moisture barrier usingH/S components

• Can adapt shield-break applications

• Pre-fabricated and tested Si-rubber

• Type tested according to IEC 60840 and IEEE 404 standards

R

EPP1061EHVS 12.07.2002 10:13 Uhr Seite 1

Page 13: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

Inline and Shield-Break Splice from 123 kV up to 170 kV

EHVS

DimensionsMax. voltage kV 123 145 170Base impulse level kV 550 650 750Conductor size mm2 (Cu/Al) 1600 1600 1400Max. outer diameter mm ≤ 92of the insulation screenLength mm 1200 1200 1200Weight complete kg 60 60 60

http://energy.tycoelectronics.com

Tyco Electronics Raychem GmbHEnergy DivisionHaidgraben 6, 85521 Ottobrunn/Munich, GermanyPhone: ++49-89-6089-0, Fax: ++49-89-6096345

ArgentinaPhone: ++54-11-4733 2277Fax: ++54-11-4733 2267AustraliaPhone: ++61-2-4390 1111Fax: ++61-2-4353 2497BrazilPhone: ++55-11-3611 1862Fax: ++55-11-3611 2457

CanadaPhone: ++1-905-475 6222Fax: ++1-905-470-4453FrancePhone: ++33-3-80583200Fax: ++33-3-80341015MexicoPhone: ++52-5-729 0405Fax: ++52-5-361-8545

ThailandPhone: ++66-2-7394026 - 32Fax: ++66-2-3260563 - 64United States of AmericaPhone: ++1-800-327-6996Fax: ++1-800-527-8350United KingdomPhone: ++44-1772-325400Fax: ++44-1772-726276

All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct andreliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance ofany particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for theseproducts is set forth in our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, Bowthorpe EMP, Critchley, Crompton, Dorman Smith, Dulmison, Guro, Hellstern, La Prairie, Morlynn, Raychem, and SIMEL are trademarks.

© T

yco

Ele

ctro

nic

s E

PP

106

1 7/

02

Major Design ElementsThe splice consists of connector (1),cable adaptors (2) – including stress cones and main splice body (3) – containing Faraday cage (4) and outer serving by heat-shrink techno-logy. The conductors of the cable are connected by a mechanical connector sleeve (1) using torque-controlled shear-off bolts. A metalshielding clamp (6) on top of the con-nector provides a smooth interface fit. A metal shielding clamp on top ofthis connector ensures perfect heattransmission. The fixing rings (5) keepthe cable dielectric in position.

The Si-rubber cable adaptors (2),accommodating the various cableinsulation diameters, will build up theconnection area to an almost constantdiameter. This makes it possible tocover four cross-section ranges withjust one main insulation splice body(3). Cross-section transitions are feasible without any extra compo-nents. No extra tooling is needed topush-on the Si-rubber cable adaptors(2) and the Si-rubber splice main body (3) due to its excellent elasticity.

Mechanical solderless connector tech-nologies (7) are used to connectmetal shields – copper wires, metalsheath and CAS.

Heat-shrink technologies (8,9) replacethe cable serving and the moisture barrier.

The joint concept is similar for theshield-break splices, despite theshield continuity. Special sealantcomponents make it possible to usecoaxial or double-insulated groundleads, and thereby to utilise theproven heat-shrink technology.

7 2 5 1 63 4 8 9

1 Mechanical connector2 Adaptor 3 Main body 4 HV electrodes5 Fixing ring6 Metal shielding clamp7 Solderless shield connection8 Conductive tubing9 Outer sealing sleeve

EPP1061EHVS 12.07.2002 10:13 Uhr Seite 2

Page 14: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

http://energy.tycoelectronics.comEnergy Division

R

Termination Systems for Polymeric Insulated Cables 72 kV

The slim, compound-free Raychem72 kV terminations are suitable forindoor and outdoor use on all poly-meric cables.

• Easy installation

• Non-tracking, heat-shrinkable outer insulation

• Heat-shrinkable stress controlsleeves

• Pre-coated track resistant sealant

• Water and corrosion resistant

• Light-weight components

• High reliability

EPP 0413 11/02 22.10.2002 17:51 Uhr Seite 5

Page 15: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

Termination Systems for Polymeric Insulated Cables 72 kV

Versatile useRaychem's 72 kV terminations aresuitable for all climates and environ-ments, even severely polluted areas,and for all installation conditions,including top feed installation. Thefactory-engineered kits contain aproven termination system whichsaves space, facilitates installationand enhances system reliability. Thespecial design of the termination,which incorporates pre-coated track-resistant sealants that melt duringthe shrinking process, results in areliable and lasting barrier againstmoisture and corrosion. Electrical stress control

Screened or shielded power cablesrequire electrical stress control inorder to reduce the electrical stressesat the end of the screen and at thetermination surface to avoid partialdischarge and surface corona underall service conditions. Corona orelectrical discharge can ultimatelydestroy the cable insulation, causingpremature failure.Raychem's stress control sleeveshave electrical properties that smoothout the electrical field at the end ofthe cable. This is achieved by theunique resistive and capacitive properties of the heat-shrinkablematerials.

This is the kit …The kit contains a limited number of light-weight components withunlimited shelf life under normalstorage conditions. The heat-shrink-able sleeves are extremely versatile,and accommodate a wide range ofcable diameters. Three basic kitscover all cable sizes, permittingreduced inventories and an efficientstocking policy.The light weight of the componentsand limited volume of the kits facili-tate safe and easy transportationand handling. All components areincluded in a single box.The set of pre-engineered compo-nents requires no special or expen-sive tools for installation. Installationinvolves a simple set of standardprocedures with no soldering re-quired. Neither does the terminationrequire filling with oil or compound.Risk of leakage is avoided, and fillingand topping-up time on the job siteis saved.

High-performance materialRaychem terminations are made of aspecially formulated material withexcellent tracking and erosion resis-tance characteristics. Acceleratedand natural weathering tests whichare constantly being carried out atRaychem facilities and independenttest sites around the world havedemonstrated that the terminationsare UV and water resistant and per-form reliably even when exposed tosudden temperature variations. A Tracking and Erosion Test as perASTM D2303 showed no tracking.IEC 112 was also conducted with noerosion or tracking observed.

10%

20% 30% 40% 50% 60% 70%

80%

90%

EPP 0413 11/02 22.10.2002 17:51 Uhr Seite 2

Page 16: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

A universal systemThe material used in Raychem's 72 kVtermination is suitable for all climatesand environments, it is not susceptibleto damage from transportation orvandalism. The termination has a discreet, low profile which allows it to blend into landscapes.

%

%

Non-tracking

heat-shrinkable

outer insulation

Outdoor

Construction and design

Indoor

Controlled torque lug

Heat-shrinkable

sheds

Heat-shrinkable

stress-control sleeves

Stress-relief material

Solderless

grounding accessory

High-voltage sealant

EPP 0413 11/02 22.10.2002 17:51 Uhr Seite 3

Page 17: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

Technical data

Cable insulation diameter range 33 to 77 mm (4 sizes)1.5 to 3.0 inches

Maximum voltage to ground 40 kVBasic impulse level outdoor ± 350 kV

indoor ± 350 kVMaximum continuous conductor 90 °Coperating temperatureMaximum conductor 130 °Cemergency temperature1 s conductor short circuit temperature 250 °CCreepage length* indoor >1450 mm (57.0 inches)

outdoor >2100 mm (82.6 inches)* Longer creepage length on request

The termination has been tested in accordance with international specifi-cations (e.g., IEEE 48, IEC 840, SEN 24 1434, ESI 09-16, EdF HN-62/5448/2,KEMA S10).Qualification by KEMA (according to KEMA S10) and by Raychem (accordingto PPS 3015) are available on request.The joint has been subjected to tests in accordance to international stan-dards e.g. IEEE 404 1993, EDF HN-68-S-20, SEN 24 1434, ESI 09-16, IEC 840.Qualification tests by KEMA (according to KEMA S10) and by Raychem(according to PPS 3015) are available on request.

Termination Systems for Polymeric Insulated Cables 72 kV

Stripping tool for XLPE cable:Raychem's stripping tool, designedto remove both semi-conductivescreen and dielectric, will help professional jointers to overcomethis difficulty.

© T

yco

Ele

ctro

nic

s E

PP

413

11/

02

Tyco Electronics Raychem GmbH, Energy DivisionFinsinger Feld 1, 85521 Ottobrunn/Munich, GermanyPhone: +49-89-6089-0, Fax: +49-89-6096345

Energy Division – a pioneer in the development of economical solutions forthe electrical power industry. Our product range includes: Cable accessories, connectors & fittings, electrical equipment, instruments, lighting, insulators &insulation enhancement and surge arresters.

For more information and your country contact person, please visit us at: http://energy.tycoelectronics.com

All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable.Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particularquality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forthin our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, BOWTHORPE EMP, CROMPTON INSTRUMENTS, DORMAN SMITH, DULMISON, GURO, HELLSTERN, LA PRAIRIE, MORLYNN, RAYCHEM, and SIMEL are trademarks.

EPP 0413 11/02 22.10.2002 17:51 Uhr Seite 4

Page 18: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base
Page 19: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base
Page 20: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base
Page 21: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

http://energy.tycoelectronics.comEnergy Division

Compact Dry Outdoor Termination from 72kV up to 145kV OHVT

The termination and its componentsare designed to operate under severeenvironmental conditions. The creepage length is adjusted tothe appropriate pollution levels of IEC 60071-1 1996, IEC 60071-2 1996and IEEE-1313.1- 1996.The comprehensive design can coverpolymeric insulated cable systems upto a cross section of 1200 mm2. Thetermination is a complete dry designand is free from any insulation liquid.

Features:

• Operates under severe conditions

• The stand alone insulator is selfsupporting

• Creepage length is adjustable

• Using torque controlled multi-contact conductor bolts

• Prefabricated and tested Silicon-rubber cone

• Short cable cut-back dimensions ~400 mm

• Fast and simple installation com-bining GIS plug-in technology withcomposite Silicon-rubber shed insulator

• No special devices, no special toolsare required

• No insulating-oil filling

• Combine novel ZnO varistor tech-nology allowing slim dimension bysuperior BIL performance

• Type tested according to IEC 60840standard

R

EPP1041 19.08.2002 17:04 Uhr Seite 1

Page 22: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

© T

yco

Ele

ctro

nic

s E

PP

104

1 8

/02

Tyco Electronics Raychem GmbH, Energy DivisionHaidgraben 6, 85521 Ottobrunn/Munich, GermanyPhone: ++49-89-6089-0, Fax: ++49-89-6096345

Energy Division – a pioneer in the development of economical solutions forthe electrical power industry. Our product range includes: Cable accessories, connectors & fittings, electrical equipment, instruments, lighting, insulators &insulation enhancement and surge arresters.

For more information and your country contact person, please visit us at: http://energy.tycoelectronics.com

All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable.Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particularquality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forthin our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, Bowthorpe EMP, Dorman Smith, Dulmison, Hellstern, La Prairie, Morlynn, Raychem, and SIMEL are trademarks.

Compact Dry Outdoor Termination from 72kV up to 145kV

OHVT

Major Design Elements

An epoxy-resin insulator with embed-ded multi-contact electrode forms theelectrically sound interface betweenthe plug-in cable termination.

Cable outer serving is adaptedthrough the gland system, whichaddresses the individual shieldingand armouring and mechanical cableoversheath fixture including sealantby prefabricated spring loadeddevices.

A torque controlled shear-off boltmulti contact connector fits the cableconductor, thus ensuring a seal to thetop assembly, without the need forspecial installation tools.

Silicon-rubber stress cone providesthe electrical field control and caneasily be applied by hand owing toits excellent elasticity.

A metal spring-loaded compressionring presses the rubber cone into theresin housing, ensuring an electricallysound interface.

Distribution of ElectricalPotential

Max. Voltage kV 72 123 145

Base Impulse Level kV 350 550 650

Cantilever Force N 5000 5000 5000

Arcing Distance mm 830 1450 1450

Specific Creepage Length cm/kV 2.2 2.2 1.9

Weight complete kg 35 60 60

Conductor Size mm2 (Cu & Al) ≤1200 ≤1200 ≤1200

Max. outer diameter mm ≤100 ≤100 ≤100of the insulation

Perc

enta

ge

EPP1041 19.08.2002 17:04 Uhr Seite 2

Page 23: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

Outdoor Composite Termination from 123 kV up to 170 kV OHVT

Application

The termination and its componentsare designed to operate under severeenvironmental conditions. The creepage length is adjusted to theappropriate pollution levels accordingto IEC 60071-1 1996, IEC 60071-2 1996and IEEE-1313.1-1996.The comprehensive design can coverpolymeric insulated cable systems upto a cross section of 2500 mm2.

Features

• Operates under severe conditions

• Creepage length is adjustable

• Pressure-tight composite housing

• Si-oil filling

• Using torque-controlled conductor bolts

• Prefabricated and tested Si-rubber cone

• Fittings are made from corrosion-resistant alloy

• Type tested according to IEEE 48 and IEC 60840 standards

R

EPP1051OHVT 12.07.2002 10:14 Uhr Seite 1

Page 24: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

Outdoor Composite Termination from 123 kV up to 170 kV

OHVT

2

1

4

5

6

7

8

3

DimensionsMax. voltage kV 123 145 170 170 170Base impulse level kV 550 650 750 750 750Cantilever force N 5000 5000 5000 5000 5000Arcing distance mm 1335 1335 1335 1500 1500Creepage distance mm 3165 3165 3750 4580 5270Pollution level IEC 60137 III II II III IV

and IEC 60072Length mm 1800 1800 2110 2110 2110Oil volume l 40 40 75 75 75Weight complete kg 130 130 165 165 165Conductor size mm2 (Cu/Al)acc. to separate tableMax. outer diameter mm ≤ 101of the insulation screen

1 Upper metal fitting 2 Mechanical connector 3 Composite housing 4 Oil-filled

5 Stress cone6 Base plate 7 Support insulators (optional)8 Gland and sealing

http://energy.tycoelectronics.com

Tyco Electronics Raychem GmbHEnergy DivisionHaidgraben 6, 85521 Ottobrunn/Munich, GermanyPhone: ++49-89-6089-0, Fax: ++49-89-6096345

ArgentinaPhone: ++54-11-4733 2277Fax: ++54-11-4733 2267AustraliaPhone: ++61-2-4390 1111Fax: ++61-2-4353 2497BrazilPhone: ++55-11-3611 1862Fax: ++55-11-3611 2457

CanadaPhone: ++1-905-475 6222Fax: ++1-905-470-4453FrancePhone: ++33-3-80583200Fax: ++33-3-80341015MexicoPhone: ++52-5-729 0405Fax: ++52-5-361-8545

ThailandPhone: ++66-2-7394026 - 32Fax: ++66-2-3260563 - 64United States of AmericaPhone: ++1-800-327-6996Fax: ++1-800-527-8350United KingdomPhone: ++44-1772-325400Fax: ++44-1772-726276

All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct andreliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance ofany particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for theseproducts is set forth in our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, Bowthorpe EMP, Critchley, Crompton, Dorman Smith, Dulmison, Guro, Hellstern, La Prairie, Morlynn, Raychem, and SIMEL are trademarks.

© T

yco

Ele

ctro

nic

s E

PP

105

1 7/

02

Major Design Elements

The pressure-tight composite housing (3) made from GFR including top andbottom non-corrosive Al- alloy fittings (1) (6), which incorporate the top andbottom assembly. Si sheds are molded INSITU to the GFR housing. Cable outer serving is adapted through a gland system (8), which addressesthe individual shielding and armoring and the sealant by heat-shrink technology.

Support insulators (7) are supplied as an option when sectionalization and cross-bonding become part of the cable transmission system and separategrounding is required.

A torque-controlled shear-off bolt connector (2) fits the cable conductor, thus ensuring a seal to the top assembly, without the need of special installa-tion tools. Heat-shrinkable polymeric tubing containing oil-resistant sealant encapsulates the connector barrel and the polymeric insulation transition.

Si-rubber stress cone (5) provides the electrical field control and can easily be applied by hand owing to its excellent elasticity.

The interface between stress cone, cable insulation and inner GFR housing isfilled with Si oil (4). Filling and release studs are available at the base plateand the top bolt assembly.

EPP1051OHVT 12.07.2002 10:14 Uhr Seite 2

Page 25: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

Compact Switchgear DRY Terminationup to 145 kV PHVS(T)

Application

The compact dry-type termination for voltages up to Um = 145kV isdesigned to be installed in cable-entry housings for gas-insulatedswitchgear (GIS). It complies with IEC 60859 standards, and accordinglymeets the interface requirements. If requested, the termination will be adapted to fit existing GIS thatdoes not comply with IEC 60859.The application cross-section is limited to 1200mm2, depending on the overall dimension of the cable.

Features

• Operates under severe conditions

• Pressure-tight resin housing

• Using torque-controlled multi-contact conductor bolts

• Prefabricated and tested Si-rubber cone

• Adapts IEC 60859 dimensions

• No Si-oil filling, dry interface

• Type tested according to IEC 60840 standard

R

EPP1031PVHS 12.07.2002 10:12 Uhr Seite 1

Page 26: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

Compact Switchgear DRY Terminationup to 145 kV

PHVS(T)

DimensionsMax. voltage kV 123 145Base impulse level kV 550 650Operating pressure SF6 hPa > 200 > 200Conductor size mm2 (Cu/Al) ... 1200Max. outer diameter of mm ≤ 75the insulation screen

Length Weightmm kg

Version A 386 27Version B 470 38Version C 757 62

http://energy.tycoelectronics.com

Tyco Electronics Raychem GmbHEnergy DivisionHaidgraben 6, 85521 Ottobrunn/Munich, GermanyPhone: ++49-89-6089-0, Fax: ++49-89-6096345

ArgentinaPhone: ++54-11-4733 2277Fax: ++54-11-4733 2267AustraliaPhone: ++61-2-4390 1111Fax: ++61-2-4353 2497BrazilPhone: ++55-11-3611 1862Fax: ++55-11-3611 2457

CanadaPhone: ++1-905-475 6222Fax: ++1-905-470-4453FrancePhone: ++33-3-80583200Fax: ++33-3-80341015MexicoPhone: ++52-5-729 0405Fax: ++52-5-361-8545

ThailandPhone: ++66-2-7394026 - 32Fax: ++66-2-3260563 - 64United States of AmericaPhone: ++1-800-327-6996Fax: ++1-800-527-8350United KingdomPhone: ++44-1772-325400Fax: ++44-1772-726276

All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct andreliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance ofany particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for theseproducts is set forth in our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, Bowthorpe EMP, Critchley, Crompton, Dorman Smith, Dulmison, Guro, Hellstern, La Prairie, Morlynn, Raychem, and SIMEL are trademarks.

© T

yco

Ele

ctro

nic

s E

PP

103

1 7/

02

Major Design Elements

An epoxy-resin insulator (3) with embedded multi-contact electrode forms the gas pressure-tight interface between GIS cable entry and ‘plug-in’ cabletermination.

Cable outer serving is adapted through a gland system (5), which addressesthe individual shielding and armouring and mechanical cable oversheath fixture including sealant by heat-shrink technology.

A torque-controlled shear-off bolt multi-contact connector (2) fits the cableconductor, thus ensuring a seal to the top assembly, without the need for special installation tools.

Si-rubber stress cone (4) provides the electrical field control and can easily be applied by hand owing to its excellent elasticity.

A metal spring-loaded compression ring (6) presses the rubber stress coneinto the resin housing, ensuring an electrically sound interface.

Various bus-bar extensions (1) accommodating different GIS specifications are available to fit the top electrode of the resin housing (3).

The same concept applies to a transformer cable entry, where a corona shieldis added to the top upper resin-housing electrode.

1

2

3

4

6

5

1 IEC Adaptor2 Mechanical connector 3 Resin housing 4 Stress cone5 Gland and sealing6 Spring-loaded compression ring

EPP1031PVHS 12.07.2002 10:12 Uhr Seite 2

Page 27: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

Switchgear and Transformer Termination from 123 kV up to 170 kVS(T)HVT

Application

The termination is designed for directinstallation into oil-filled cable entries(power transformers) and gas-insu-lated switchgear (GIS). Upon request,the termination can be adapted to anexisting switchgear or transformer.Cross-sections up to 2500 mm2 areapplicable.

Features

• Operates under severe conditions

• Pressure-tight resin housing

• Si-oil filling

• Uses torque-controlled conductor connectors

• Prefabricated and tested Si-rubber cone

• Fittings are made from corrosion- resistant alloy

• Type tested according to IEC-60859 Standard

R

EPP1021SVHT 18.07.2002 10:45 Uhr Seite 1

Page 28: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

Switchgear and Transformer Termination from 123 kV up to 170 kV

S(T)HVT

DimensionsMax. voltage kV 123 145 170Base impulse level kV 550 650 750Cantilever force N 6500 6500 6500Creepage distance mm 650 650 650Oil volume l 12 12 12Weight kg 92 92 92Conductor size mm2 (Cu/Al) ... 1600Max. outer diameter mm ≤ 101of the insulation screen

3

2

1

4

6

5

7

http://energy.tycoelectronics.com

Tyco Electronics Raychem GmbHEnergy DivisionHaidgraben 6, 85521 Ottobrunn/Munich, GermanyPhone: ++49-89-6089-0, Fax: ++49-89-6096345

ArgentinaPhone: ++54-11-4733 2277Fax: ++54-11-4733 2267AustraliaPhone: ++61-2-4390 1111Fax: ++61-2-4353 2497BrazilPhone: ++55-11-3611 1862Fax: ++55-11-3611 2457

CanadaPhone: ++1-905-475 6222Fax: ++1-905-470-4453FrancePhone: ++33-3-80583200Fax: ++33-3-80341015MexicoPhone: ++52-5-729 0405Fax: ++52-5-361-8545

ThailandPhone: ++66-2-7394026 - 32Fax: ++66-2-3260563 - 64United States of AmericaPhone: ++1-800-327-6996Fax: ++1-800-527-8350United KingdomPhone: ++44-1772-325400Fax: ++44-1772-726276

All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct andreliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance ofany particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for theseproducts is set forth in our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, Bowthorpe EMP, Critchley, Crompton, Dorman Smith, Dulmison, Guro, Hellstern, La Prairie, Morlynn, Raychem, and SIMEL are trademarks.

© T

yco

Ele

ctro

nic

s E

PP

102

1 7/

02

Major Design Elements

An epoxy-resin insulator (2) with embedded electrode forms the gas pressure-tight interfacebetween GIS cable entry and the oil pressure-tightinterface between the transformer cable boxes.

Cable outer serving is adapted through a gland sys-tem (6), which addresses the individual shieldingand armouring and the sealant by heat-shrink technology.

The base plate (5) including sealing gaskets providethe interface fit between the resin housing andcable entry.

A torque-controlled shear-off bolt connector (1) fitsthe cable conductor assuring the sealing to the topassembly without use of special installation tools.Heat-shrinkable polymeric tubing containing oil-resistant sealant encapsulates the connector barreland the polymeric insulation transition.

Si-rubber stress cone (4) provides the electrical fieldcontrol and can easily be applied by hand owing toits excellent elasticity.

The interface between stress cone, cable insulationand inner resin-housing is filled with Si Oil (3).Filling and release studs are available at the baseplate and the top bolt assembly.For top-down or horizontal installations an oilextension vessel can be provided on request.

The same concept applies to a transformer cableentry, where a corona shield is added to the topupper resin housing electrode.

1 Mechanical connector 2 Composite housing 3 Oil-filled4 Stress cone5 Base plate 6 Gland and sealing7 Corona shield

EPP1021SVHT 18.07.2002 10:45 Uhr Seite 2

Page 29: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

Miscellaneous Product Data EPPA 055 Link Box

Raychem Product Guide 1 Effective: 18.10.00Electrical Products Section 6 Supersedes: 12/93Division

Typical ApplicationEPPA 055 is a Link Box, used for cross bonding and sectionalisation for high-voltage cable systems.

The link box can be used as grounding box or as link box, equipped with shield voltage limiters (SVL).The link box is normally used with Raychem EHVS joints with shield break (MOD Code –01).

Material: Link Box: stainless steel. SVL: Zinc oxide ZnO3 .

Part No. Number ofphases

Sheath voltagelimiter

DimensionsL (mm) W (mm) H (mm)

EPPA-055-0/1 Direct grounding 1 --- 300 190 165EPPA-055-3/1 Cross bonding 1 3 kV 300 190 165EPPA-055-6/1 Cross bonding 1 6 kV 300 190 165EPPA-055-0/3 Direct grounding 3 --- 310 310 255EPPA-055-3/3 Cross bonding 3 3 kV 310 310 255EPPA-055-6/3 Cross bonding 3 6 kV 310 310 255

Literature: Test Report PPR 1168 Type Test of Link Box LBOX3-ZnO-3PPR 1449 Type Test of Link Box EPPA-055-6/3

Brochure EPP 0865

3-Phase Link Box: EPPA-055-x/31-Phase Link Box EPPA-055-x/1

H

W

L

W

L

H

Page 30: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

R HV Torque ControlledLugs and Connectors

Features

Torque controlled shear off bolts

Application range

Connectors

Lugs

Benefits

– fast and safe installation– excellent electrical performance– excellent mechanical performance– easy installation with standard box

spanner

– pre-engineered design for perfect fit– Cu and Al conductors– up to 1600 mm2

– straight and size transition type– body made of aluminum alloy

– variety of different palms available– body made of tinned aluminum alloy

Designed for heat-shrinkable joints and terminations

Lugs/Connect. 03.03.2000 10:58 Uhr Seite 1

Page 31: Section 9: High Voltage Joints & Terminations. 12.07.2002 10:13 Uhr Seite 1 Inline and Shield-Break Splice from 123 kV up to 170 kV EHVS Dimensions Max. voltage kV 123 145 170 Base

© R

aych

em E

PP 0

850

3/00

Description DimensionsHV mechanical connector EPPA-047-xx/XX-LLL L = 130 mm/180 mmfor straight connection x, X according to cable dimensions*

HV mechanical connector EPPA-047-xx/XX-yy/YY-LLL L = 130 mm/180 mmfor size transition x, X, y; Y according to cable dimensions*

Cable lug with rod Ø 30 mm EPPA-050-xx/XX L = 190 mm l = 100 mm a = 64 mm Ø = 30 mmx, X according to cable dimensions

Cable lug with rod Ø 40 mm EPPA-053-xx/XX L = 264 mm l = 125 mm a = 108 mm Ø = 40 mmx, X according to cable dimensions*

Cable lug with 1-hole pad EPPA-052-xx/XX L = 190 mm l1 = 100 mm l2 = 50 mma = 64 mm d = 18 mmx, X according to cable dimensions*

Cable lug with 2-hole pad EPPA-051-xx/XX L = 190 mm l1 = 100 mm l2 = 45 mm l3 = 27,5 mma = 64 mm d = 17 mmx, X according to cable dimensions*

Cable lug with 4-hole NEMA pad EPPA-054-xx/XX L = 232 mm l1 = 100 mm (80 mm) l2 = 45 mma = 112 mm d = 18 mmx, X according to cable dimensions*

*Diameter over conductor and diameter over dielectric

www.tycoelectronics.com

All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate thesuitability of each product for the desired application. Under no cirumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or expli-cit contractual arrangements. Our liability for this product is set forth in our standard terms and conditions of sale. AMP, ELCON, ELO TOUCHSYSTEMS, HTS, M/ACOM, MADISON, NETCONNECT, RAYCHEM, SIMEL are trademarks of Tyco International Ltd.

Tyco Electronics Raychem GmbHEnergy DivisionHaidgraben 685521 Ottobrunn/Munich GermanyTel. (089) 6089-0 Fax (089) 609 63 45

Tyco Electronics CorporationEnergy Divisionc/o AMP Singapore Pte LtdNo. 26 Ang Mo Kio Industrial Park 2Singapore 569507Tel. 65-4836012Fax 65-4836031

Tyco Electronics CorporationEnergy Division8000 Purfoy RoadFuquay-Varina, NC 27526-9349, USATel. (800) 327-6996Fax (800) 527-8350

Members of the Tyco Electronics Corporation:

• Wedge technology products • Electrical connectors • Cable accessories • Asset protection • Surge arresters • Insulators • Fittings • Associated toolings

EPPA-047-xx/XX-LLL EPPA-047-xx/XX-yy/YY-LLL EPPA-050-xx/XX, EPPA-053-xx/XX

EPPA-052-xx/XX EPPA-051-xx/XX EPPA-054-xx/XX

HV Torque Controlled Lugs and Connectors

Lugs/Connect. 03.03.2000 10:58 Uhr Seite 2