section e: pedestrian wayfinding - rutgers university · 2020-01-23 · rutgers university...

88
SECTION E: PEDESTRIAN WAYFINDING PDR10 SERIES PEDESTRIAN DIRECTIONAL PDR20 SERIES PEDESTRIAN DIRECTIONAL WITH ORIENTATION MAP ORT10 SERIES ORIENTATION MAP Some pedestrian wayfinding signs were implemented prior to the completion of this Universitywide Standard. These signs have been documented and are represented in this section. There are some pedestrian wayfinding signs that are unique to the Health Science campus and can be found in Section J of this manual.

Upload: others

Post on 10-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

SECTION E:

PEDESTRIANWAYFINDINGPDR10 SERIES PEDESTRIAN DIRECTIONAL

PDR20 SERIES PEDESTRIAN DIRECTIONAL

WITH ORIENTATION MAP

ORT10 SERIES ORIENTATION MAP

Some pedestrian wayfinding signs were implemented prior

to the completion of this Universitywide Standard. These

signs have been documented and are represented in this

section. There are some pedestrian wayfinding signs that are

unique to the Health Science campus and can be found in

Section J of this manual.

Page 2: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.22E.2

This Page Intentionally Left Blank

Page 3: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

SECTION E:

PDR10 SERIES

SUB-SECTION

Page 4: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

2E.4 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

PDR10 Series – Pedestrian Directional

PDR11Config. 1

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

PDR12

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

PDR11Config. 2

MessageMessage

MessageMessage

MessageMessage

MessageMessageMessage

PDR13Config. 1

Lot XXAddress

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

PDR13Config. 2

Lot XXAddress

MessageMessage

MessageMessage

MessageMessage

MessageMessageMessage

PDR14Config. 2

Lot XXAddress

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

PDR15Config. 1

Lot XXAddress

Lot XXAddress

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

PDR15Config. 2

Lot XXAddress

Lot XXAddress

MessageMessage

MessageMessage

MessageMessage

MessageMessageMessage

PDR10 Series Overview

Recommended sign type

configurations shown.

Additional module

configurations must be

approved by Rutgers

University Environmental

Graphics Coordinator &

or Department of Facilities,

Planning and Development

Below are the following steps for

selecting the correct pedestrian

directional for your needs.

A. Determine the number of

messages and parking messages

you require.

B. Determine message lengths

and character (letter) counts for

each message. Are your

messages 1, 2 or 3 lines long?

C. Select from the typical module

heights based on previous steps.

See graphic layout pages for

sample typographic layouts.

D. Review graphic dont’s to

ensure proper selection.

Sign Selection Process

Questions? Please contact xxxxx

?

1 MSG 2 MSG 3 MSG 4 MSG 5 MSG 6 MSG4 MSG

+ 1 PARK

4 MSG

+ 2 PARK

3 MSG

+ 3 PARK

3 MSG

+ 1 PARK

3 MSG

+ 2 PARK

3 ARROW N/A N/A N/A N/A N/A N/A N/A

PDR125 ARROW N/A N/A N/A N/AN/AN/AN/AN/A

4 ARROW N/A N/A N/AN/A N/AN/AN/AN/A N/A

PDR126 ARROW N/A N/A N/A N/A N/A N/A N/A N/A

2 ARROW N/A N/A N/A N/A N/A N/A

N/A N/A N/A

N/A N/A N/A N/A

1 ARROW N/APDR11

Config. 2

PDR11Config. 2

N/A N/A N/A N/A N/A N/A N/A N/A N/A

PDR10 SERIES:

PDR11Config. 2

PDR11Config. 2

PDR11Config. 1

PDR13Config. 1

PDR15Config. 2

PDR15Config. 1

PDR15Config. 2

PDR13Config. 2

PDR14Config. 2

Page 5: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessageMessage

Configuration 1 Configuration 2

27"

a

C

D

HB

E

G

F

I

J

Full length filler panels are used for single sided signs only. (not shown)

Stop panel below grade line. (not shown)

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT PEDESTRIAN DIRECTIONAL

PDR11

PART COUNTS

POST CAP POST CAP

SIGN POST SIGN POST

PNL.1 PNL.1

FP_1 FP_1

PNL.2 PNL.3

PNL.4

FP_2

FP_2

FP_3

FP_3

FP_S

FP_S

2 2

2 2

1 1

4 4

1 1

1

2

2

2

2

4

4

2 2

2 2

2 2

8 8

2 2

2

4

4

0

0

4

4

CONFIGURATION 1: CONFIGURATION 2:

SINGLE SIDED

SINGLE SIDED

DOUBLE SIDED

DOUBLE SIDED

A A

B B

C C

D D

E E

G H

H

I

I

J

J

* *

* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.

For specification and ordering purposes, contact EMS Delaware;

231 Executive Drive Suite 11

Newark, DE 19702 USA

Toll Free: 800-863-1496

Local Phone: 302-391-1370

Fax: 302-391-1371

Website: www.EasternMetal.com

Email: [email protected]

CONFIGURATIONS

Helpful Hints

• Keep in mind the intuitive

path of the user when locat-

ing and specifying exterior

directional signs.

• Use only standard and

approved nomenclature

and abbreviations.

• Refer to all appropriate state

and local codes, as needed,

for sign compliance, includ-

ing, but not limited to zon-

ing, ADAAG, MUTCD, etc.

• Sign fabricator to provide

all relevant engineering

calculations and provide all

methods and materials

of construction in

shop drawings.

Guidelines

• Provide pedestrians with

sequential guidance

throughout the campus with

strategic placement and

programmed messaging.

• Reinforce the brand equity

in the built environment with

brand color on the header.

• Use as a single-sided or

double-sided sign. Message

standards apply to both sides

of sign. It is acceptable to

use a different configuration

on each side.

• Locate signs at key decision

points and at locations

of optimal line of sight

from public buildings and

campus core.

• Arrow order should be as

follows: Up (straight),

Left, Right.

• Do not rearrange panel order.

PARTS

2E.5

Questions? Please contact xxxxx

?

SECTION E: PEDESTRIAN WAYFINDING

Page 6: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessageMessage

1/8"

4"1"

1'-8

15/

16"

1"8"

2'-3

"2"

min

.

5'-2

"

2'-6

"

eq.

6"eq

.

1'-4

"

3/4"2'-0"- graphic panel

3/4"

3 1/4" 1'-7" 3 1/4"

eq. 2'-1 1/2" eq.

2'-9 1/2"

grade line

A

CD

D

BH

CEF

CEF

G

G

E

G

IBA

J

F

I

PDR11: Configuration 1 3/4” = 1’-0”

Plan Elevation-Single side Sign(double side panels shown dashed)

DR33: Configuration 1, 21/2” = 1’-0”

PDR11: Configuration 23/4” = 1’-0”

Back Elevation- Single side Sign(panel configurationvaries, 1 shown)

KL

KL

2E.6

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P1. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E PNL.2 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P2.

*Use one panel only for single sided sign.

F PNL.3 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P3.

*Use one panel only for single sided sign.

PDR11PEDESTRIAN DIRECTIONAL

Page 7: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

2E.7

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

This Page Intentionally Left Blank

G PNL.5 Painted aluminum panel

w/ applied vinyl graphics.

Custom extruded panel

attachment to be mounted

to back of panel w/ hi-bond

adhesive. Paint all sides: P3.

*Use one panel only for single sided sign.

H FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

I FP_3 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1. *Use only for single sided signs.

J FP_S 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

K Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

L Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

SECTION E: PEDESTRIAN WAYFINDING

PEDESTRIAN DIRECTIONAL

PDR11

Page 8: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

becomessign panel

Component Parts /Assembly

Finished Sign

C

A

O

D

B

EFG

H

I

P

M

N

2E.8

DETAIL

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post

cap, mechanically fastened

w/ tamper-resistant, span-

ner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P1. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E PNL.2 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P2.

*Use one panel only for single sided sign.

F PNL.3 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P3.

*Use one panel only for single sided sign.

PDR11PEDESTRIAN DIRECTIONAL

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

Page 9: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

3'-2" panel length

3/4" 1 3/4" 3/4"

3 1/4"

1/8"typ.

2"

1/8"

typ

.

7/8"

4 1/

4"7/

8"

6"

1/8"7/8"

1/8"

1 1/8"

1/4"

pan

el e

xtru

sio

n v

arie

s-se

e el

evat

ion

s fo

r h

eig

ht

dim

ensi

on

s

1/4"

pan

el h

eig

ht

vari

es-

see

elev

atio

ns

for

hei

gh

t d

imen

sio

ns

4" a

bov

e fi

nis

hed

gra

de

Partial Horizontal Section 6” = 1’-0”

Vertical Section: Concrete Footerno scale

Plan Elevation at Sidewalkno scale

Panel Detail no scale

EFG

FE

G

G

B

P

O

O

P

grade line grade line

B

L

M

N

H

K

L

M

at concrete sidewalk condition

Vertical Section: Concrete Footerno scale

at earth / grass condition

2E.9

DETAIL

Specifications

SECTION E: PEDESTRIAN WAYFINDING

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

G PNL.4 Painted aluminum panel

w/ applied vinyl graphics.

Custom extruded panel

attachment to be mounted

to back of panel w/ hi-bond

adhesive. Paint all sides: P2.

*Use one panel only for single sided sign.

H FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

I FP_7 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1. *Use only for single sided signs.

K Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

L Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

M Expansion Joint To accommodate concrete

expansion and contraction.

N Sand Compacted sand for con-

densation drainage per

engineering requirements.

O Attachment Bracket Rutgers owned custom ex-

truded bracket cut to match

height of aluminum plate.

Permanently mount to back

of plate.

*See post extrusion spec. information on Parts sheet.

P Sign Panel Plate 1/8” Thk. aluminum plate cut

to dimensions shown

in elevations.

PEDESTRIAN DIRECTIONAL

PDR11

Page 10: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Lot XXAddress

Up to TwoLine Message

Up to TwoLine Message

Up to Three LineMessage

alig

nal

ign

Up to Two Line Message

Up to Two Line Message

Up to Two Line Message

Up toThree LineMessage

aB

aB

B

d

C

a

PNL.3 (max. message)1” = 1’-0”

PNL.2 (max. message)1” = 1’-0”

PNL.3 (max. message)1” = 1’-0”

CL

C L -

typ

.C L

CL

C L -

typ

.

CL CL

3" 2 1/4" 1'-4 1/4"- max. copy length

3"2"

-ty

p.

4"-

typ

.

1 1/

4"

3" 2 1/4" 1'-4 1/4"- max. copy length

3"2"

-ty

p.

4"-

typ

.

1 1/

4"1

1/4"

1 1/

4"

3" 2 5/8" 1 1/2"1'-2 1/2"-

max. copy length

3 3/

16"

2"

2E.10

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.10

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

GRAPHIC LAYOUTS

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A Copy 1 1/4” X-cap Height.

Type: T2. Tracking: +50.

Apply to front surface

of panel.

Applied Vinyl: V2.

B Arrow_Symbol.eps 1 3/4” Height.

Artwork provided by client.

Apply to front surface

of panel.

Applied Vinyl: V2. Rotate arrow around object

center-point.

C Copy 1 1/4” X-cap Height.

Type: T1. Tracking: +50.

Apply to front surface

of panel.

Applied Vinyl: V2.

D Parking_Symbol.eps 1 1/2” Height.

Artwork provided by client.

Apply to front surface

of panel.

Applied Vinyl: V2, V1.

PDR11PEDESTRIAN DIRECTIONAL

Page 11: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Visitors Must UseMain Entrance

University BehavioralHealth Care

No more than SIX messagesper sign.

ONLY includeparking messageson parking panels

No more than THREE lines per message.

Panels must MATCH the 27’’baseline.

Do NOT rearrangepanels.

PNL.2/PNL.3- Variation1” = 1’-0”

E2 3/

8"1

5/8"

1"

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

Message

Message

Message

Message

Message

Message

Message

MessageMessageMessage

MessageMessage

MessageMessage

Message

MessageMessage

Lot XXAddress

Lot XXAddress

Lot XXAddress

Lot XXAddress

2E.11

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

2E.11

GRAPHIC DONT’S

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

E Secondary Copy 1” X-cap Height.

Type: T1. Tracking: +50.

Apply to front surface

of panel.

Applied Vinyl: V2.

GRAPHIC LAYOUTS

SECTION E: PEDESTRIAN WAYFINDING

PEDESTRIAN DIRECTIONAL

PDR11

Page 12: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

2E.12 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

This Page Intentionally Left Blank

Page 13: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

Configuration 1

27"’

a

C

D

FB

E

G

H

Full length filler panels are used for single sided signs only. (not shown)

Stop panel below grade line. (not shown)

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR12

PART COUNTS

POST CAP

SIGN POST

PNL.1

FP_1

PNL.5

FP_2

FP_7

FP_S

2

2

1

2

1

2

2

4

2

2

2

4

2

4

0

4

CONFIGURATION 1:

SINGLE SIDED

DOUBLE SIDED

A

B

C

D

E

F

G

H

*

* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.

For specification and ordering purposes, contact EMS Delaware;

231 Executive Drive Suite 11

Newark, DE 19702 USA

Toll Free: 800-863-1496

Local Phone: 302-391-1370

Fax: 302-391-1371

Website: www.EasternMetal.com

Email: [email protected]

CONFIGURATIONS

PEDESTRIAN DIRECTIONAL

Helpful Hints

• Keep in mind the intuitive

path of the user when locat-

ing and specifying exterior

directional signs.

• Use only standard and

approved nomenclature

and abbreviations.

• Refer to all appropriate state

and local codes, as needed,

for sign compliance, includ-

ing, but not limited to zon-

ing, ADAAG, MUTCD, etc.

• Sign fabricator to provide

all relevant engineering

calculations and provide all

methods and materials

of construction in

shop drawings.

Guidelines

• Provide pedestrians with

sequential guidance

throughout the campus with

strategic placement and

programmed messaging.

• Reinforce the brand equity

in the built environment with

brand color on the header.

• Use as a single-sided or

double-sided sign. Message

standards apply to both sides

of sign. It is acceptable to

use a different configuration

on each side.

• Locate signs at key decision

points and at locations

of optimal line of sight

from public buildings and

campus core.

• Arrow order should be as

follows: Up (straight),

Left, Right.

• Do not rearrange panel order.

PARTS

2E.13

Questions? Please contact xxxxx

?

SECTION E: PEDESTRIAN WAYFINDING

Page 14: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

1/8"

4"1"

2'-3

"2"

min

.

5'-2

"

eq.

6"eq

.

1'-4

"

3/4"2'-0"- graphic panel

3/4"

3 1/4" 1'-7" 3 1/4"

eq. 2'-1 1/2" eq.

2'-9 1/2"

3'-2

"

grade line

A

CD

BF

CEF

CEF

G

G

E

gBA

g

PDR12 3/4” = 1’-0”

Plan Elevation-Single side Sign(double side panels shown dashed)

DR33: Configuration 1, 21/2” = 1’-0”

Back Elevation- Single side Sign

ij

KL

H

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

2E.14

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P1. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E PNL.4 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P2.

*Use one panel only for single sided sign.

F FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

G FP_7 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

J FP_S 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

PDR12PEDESTRIAN DIRECTIONAL

Page 15: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

2E.15

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

This Page Intentionally Left Blank

K Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and

appropriate wind-loads for

individual structure. Footer

to be below grade and

landscaping, by others,

where necessary.

L Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

SECTION E: PEDESTRIAN WAYFINDING

PEDESTRIAN DIRECTIONAL

PDR12

Page 16: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

becomessign panel

Component Parts /Assembly

Finished Sign

C

A

M

D

B

E

F

G

N

M

N

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

2E.16

DETAIL

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post

cap, mechanically fastened

w/ tamper-resistant, span-

ner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P1. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E PNL.4 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P2.

*Use one panel only for single sided sign.

F FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

G FP_7 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1. *Use only for single sided signs.

PDR12PEDESTRIAN DIRECTIONAL

Page 17: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

3'-2" panel length

3/4" 1 3/4" 3/4"

3 1/4"

1/8"typ.

2"

1/8"

typ

.

7/8"

4 1/

4"7/

8"

6"

1/8"7/8"

1/8"

1 1/8"

1/4"

pan

el e

xtru

sio

n v

arie

s-se

e el

evat

ion

s fo

r h

eig

ht

dim

ensi

on

s

1/4"

pan

el h

eig

ht

vari

es-

see

elev

atio

ns

for

hei

gh

t d

imen

sio

ns

4" a

bov

e fi

nis

hed

gra

de

Partial Horizontal Section 6” = 1’-0”

Vertical Section: Concrete Footerno scale

Plan Elevation at Sidewalkno scale

Panel Detail no scale

E

E

G

B

N

M

M

N

grade line grade line

B

J

K

L

I

I

J

K

at concrete sidewalk condition

Vertical Section: Concrete Footerno scale

at earth / grass condition

2E.17

DETAIL

Specifications

SECTION E: PEDESTRIAN WAYFINDING

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

I Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and

appropriate wind-loads for

individual structure. Footer

to be below grade and

landscaping, by others,

where necessary.

J Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

K Expansion Joint To accommodate concrete

expansion and contraction.

L Sand Compacted sand for con-

densation drainage per

engineering requirements.

M Attachment Bracket Rutgers owned custom ex-

truded bracket cut to match

height of aluminum plate.

Permanently mount to back

of plate.

*See post extrusion spec. information on Parts sheet.

N Sign Panel Plate 1/8” Thk. aluminum plate cut

to dimensions shown

in elevations.

PEDESTRIAN DIRECTIONAL

PDR12

Page 18: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Up to TwoLine Message

Up to TwoLine Message

Up to TwoLine Message

Up to TwoLine Message

Up to TwoLine Message

Up to TwoLine Message

alig

n

PNL.4 (max. message)1” = 1’-0”

AB

CL

C L -

typ

.

3" 2 1/4" 1'-4 1/4"- max. copy length

3"2"

-ty

p.

4"-

typ

.

1 1/

4"

2E.18

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.18

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

GRAPHIC LAYOUTS

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A Copy 1 1/4” X-cap Height.

Type: T2. Tracking: +50.

Apply to front surface

of panel.

Applied Vinyl: V2.

B Arrow_Symbol.eps 1 3/4” Height.

Artwork provided by client.

Apply to front surface

of panel.

Applied Vinyl: V2. Rotate arrow around object

center-point.

PDR12PEDESTRIAN DIRECTIONAL

Page 19: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Visitors Must UseMain Entrance

University BehavioralHealth Care

No more than SIX messagesper sign.

ONLY includeparking messageson parking panels

No more than THREE lines per message.

Panels must MATCH the 27’’baseline.

Do NOT rearrangepanels.

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessageMessageMessageMessage

MessageMessage

MessageMessage

Message

Message

Message

Message

Message

MessageMessage

Lot XXAddress

Lot XXAddress

Lot XXAddress

Lot XXAddress

Lot XXAddress

Lot XXAddress

PNL.3- Variation1” = 1’-0”

C2 3/

8"1

5/8"

1"

2E.19

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

2E.19

GRAPHIC DONT’S

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

C Secondary Copy 1” X-cap Height.

Type: T1. Tracking: +50.

Apply to front surface

of panel.

Applied Vinyl: V2.

GRAPHIC LAYOUTS

SECTION E: PEDESTRIAN WAYFINDING

PEDESTRIAN DIRECTIONAL

PDR12

Page 20: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

2E.20 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

This Page Intentionally Left Blank

Page 21: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Lot XX

Lot XX

Address

Address

MessageMessage

MessageMessage

MessageMessageMessage

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

MessageMessage

Configuration 1 Configuration 2

26"

a

C

D

HB

E

G

F

I

J

Full length filler panels are used for single sided signs only. (not shown)

Stop panel below grade line. (not shown)

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

CONFIGURATIONS

PDR13

PART COUNTS

POST CAP POST CAP

SIGN POST SIGN POST

PNL.1 PNL.1

FP_1 FP_1

PNL.2 PNL.3

PNL.4

FP_2

FP_2

FP_3

FP_3

FP_S

FP_S

2 2

2 2

1 1

4 4

1 1

1

2

2

2

2

4

4

2 2

2 2

2 2

8 8

2 2

2

4

4

0

0

4

4

CONFIGURATION 1: CONFIGURATION 2:

SINGLE SIDED

SINGLE SIDED

DOUBLE SIDED

DOUBLE SIDED

A A

B B

C C

D D

E E

G H

H

I

I

J

J

* *

* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.

For specification and ordering purposes, contact EMS Delaware;

231 Executive Drive Suite 11

Newark, DE 19702 USA

Toll Free: 800-863-1496

Local Phone: 302-391-1370

Fax: 302-391-1371

Website: www.EasternMetal.com

Email: [email protected]

PEDESTRIAN DIRECTIONAL

Helpful Hints

• Keep in mind the intuitive

path of the user when locat-

ing and specifying exterior

directional signs.

• Use only standard and

approved nomenclature

and abbreviations.

• Refer to all appropriate state

and local codes, as needed,

for sign compliance, includ-

ing, but not limited to zon-

ing, ADAAG, MUTCD, etc.

• Sign fabricator to provide

all relevant engineering

calculations and provide all

methods and materials

of construction in

shop drawings.

Guidelines

• Provide pedestrians with

sequential guidance

throughout the campus with

strategic placement and

programmed messaging.

• Reinforce the brand equity

in the built environment with

brand color on the header.

• Use as a single-sided or

double-sided sign. Message

standards apply to both sides

of sign. It is acceptable to

use a different configuration

on each side.

• Locate signs at key decision

points and at locations

of optimal line of sight

from public buildings and

campus core.

• Arrow order should be as

follows: Up (straight),

Left, Right.

• Do not rearrange panel order.

PARTS

2E.21

Questions? Please contact xxxxx

?

SECTION E: PEDESTRIAN WAYFINDING

Page 22: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Lot XX

Lot XX

Address

Address

MessageMessage

MessageMessage

MessageMessageMessage

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

MessageMessage

eq.

6"eq

.

1'-4

"

3/4"2'-0"- graphic panel

3/4"

3 1/4" 1'-7" 3 1/4"

eq. 2'-1 1/2" eq.

2'-9 1/2"

1/8"

4"2"

min

.

5'-2

"

1"1'

-9"

1"8"

1"8"

2'-2

"

2'-6

"

1"

8"

grade line

CEF

CEF

G

G

IBA

I

PDR11: Configuration 1 3/4” = 1’-0”

Plan Elevation-Single side Sign(double side panels shown dashed)

DR33: Configuration 1, 21/2” = 1’-0”

PDR11: Configuration 23/4” = 1’-0”

Back Elevation- Single side Sign(panel configurationvaries, 1 shown)

KL

KL

A

CD

D

D

BH

E

G

G

F

J

2E.22

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post

cap, mechanically fastened

w/ tamper-resistant, span-

ner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P1. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E PNL.2 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P2.

*Use one panel only for single sided sign.

F PNL.3 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P3.

*Use one panel only for single sided sign.

PDR13PEDESTRIAN DIRECTIONAL

Page 23: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

2E.23

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

This Page Intentionally Left Blank

G PNL.4 Painted aluminum panel

w/ applied vinyl graphics.

Custom extruded panel

attachment to be mounted

to back of panel w/ hi-bond

adhesive. Paint all sides: P3.

*Use one panel only for single sided sign.

H FP_4 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

I FP_7 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1. *Use only for single sided signs.

J FP_S 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

K Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

L Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

SECTION E: PEDESTRIAN WAYFINDING

PEDESTRIAN DIRECTIONAL

PDR13

Page 24: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

becomessign panel

Component Parts /Assembly

Finished Sign

C

A

O

D

B

EFG

H

I

P

M

N

2E.24

DETAIL

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR13PEDESTRIAN DIRECTIONAL

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P1. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E PNL.2 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P2.

*Use one panel only for single sided sign.

F PNL.3 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P3.

*Use one panel only for single sided sign.

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

Page 25: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

3'-2" panel length

3/4" 1 3/4" 3/4"

3 1/4"

1/8"typ.

2"

1/8"

typ

.

7/8"

4 1/

4"7/

8"

6"

1/8"7/8"

1/8"

1 1/8"

1/4"

pan

el e

xtru

sio

n v

arie

s-se

e el

evat

ion

s fo

r h

eig

ht

dim

ensi

on

s

1/4"

pan

el h

eig

ht

vari

es-

see

elev

atio

ns

for

hei

gh

t d

imen

sio

ns

4" a

bov

e fi

nis

hed

gra

de

Partial Horizontal Section 6” = 1’-0”

Vertical Section: Concrete Footerno scale

Plan Elevation at Sidewalkno scale

Panel Detail no scale

EFG

EFG

G

B

P

O

O

P

grade line grade line

B

l

m

N

K

K

L

M

at concrete sidewalk condition

Vertical Section: Concrete Footerno scale

at earth / grass condition

2E.25

DETAIL

Specifications

SECTION E: PEDESTRIAN WAYFINDING

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT PEDESTRIAN DIRECTIONAL

PDR13

G PNL.4 Painted aluminum panel

w/ applied vinyl graphics.

Custom extruded panel

attachment to be mounted

to back of panel w/ hi-bond

adhesive. Paint all sides: P2.

*Use one panel only for single sided sign.

H FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

I FP_7 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1. *Use only for single sided signs.

K Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

L Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

M Expansion Joint To accommodate concrete

expansion and contraction.

N Sand Compacted sand for con-

densation drainage per

engineering requirements.

O Attachment Bracket Rutgers owned custom ex-

truded bracket cut to match

height of aluminum plate.

Permanently mount to back

of plate.

*See post extrusion spec. information on Parts sheet.

P Sign Panel Plate 1/8” Thk. aluminum plate cut

to dimensions shown

in elevations.

Page 26: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Lot XXAddress

Up to TwoLine Message

Up to TwoLine Message

Up to Three LineMessage

alig

n

Up to Two Line Message

Up to Two Line Message

Up to Two Line Message

Up toThree LineMessage

alig

naB

B

d

C

a

PNL.3 (max. message)1” = 1’-0”

PNL.2 (max. message)1” = 1’-0”

PNL.3 (max. message)1” = 1’-0”

C L

CL

C L -

typ

.

CL CL

3" 2 1/4" 1'-4 1/4"- max. copy length

3"2"

-ty

p.

4"-

typ

.

1 1/

4"1

1/4"

1 1/

4"

3" 2 5/8" 1 1/2"1'-2 1/2"-

max. copy length

3 3/

16"

2"

2E.26

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.26

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

GRAPHIC LAYOUTS

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A Copy 1 1/4” X-cap Height.

Type: T2. Tracking: +50.

Apply to front surface

of panel.

Applied Vinyl: V2.

B Arrow_Symbol.eps 1 3/4” Height.

Artwork provided by client.

Apply to front surface

of panel.

Applied Vinyl: V2. Rotate arrow around object

center-point.

C Copy 1 1/4” X-cap Height.

Type: T1. Tracking: +50.

Apply to front surface

of panel.

Applied Vinyl: V2.

D Parking_Symbol.eps 1 1/2” Height.

Artwork provided by client.

Apply to front surface

of panel.

Applied Vinyl: V2, V1.

PDR13PEDESTRIAN DIRECTIONAL

Page 27: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Visitors Must UseMain Entrance

University BehavioralHealth Care

No more than SIX messagesper sign.

ONLY includeparking messageson parking panels

No more than THREE lines per message.

Panels must MATCH the 26’’baseline.

Do NOT rearrangepanels.

Lot XX

Lot XX

Address

Address

Message

Message

Message

Message

Message

Lot XX

Lot XX

Address

Address

MessageMessage

MessageMessageMessageMessageMessageMessage

Lot XX

Lot XX

Address

Address

Lot XX

Lot XX

Address

Address

MessageMessage

MessageMessage

MessageMessageMessage

Lot XX

Lot XX

Address

Address

MessageMessage

MessageMessage

MessageMessageMessage

Lot XXAddress

Lot XXAddress

Lot XXAddress

PNL.2/PNL.3- Variation1” = 1’-0”

E2 3/

8"1

5/8"

1"

2E.27

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

2E.27

GRAPHIC DONT’S

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

E Secondary Copy 1” X-cap Height.

Type: T1. Tracking: +50.

Apply to front surface

of panel.

Applied Vinyl: V2.

GRAPHIC LAYOUTS

SECTION E: PEDESTRIAN WAYFINDING

PEDESTRIAN DIRECTIONAL

PDR13

Page 28: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

2E.28 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

This Page Intentionally Left Blank

Page 29: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

Lot XXAddress

Configuration 1

18"

a

C

D

GB

E

F

H

I

Full length filler panels are used for single sided signs only. (not shown)

Stop panel below grade line. (not shown)

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR14

PART COUNTS

CONFIGURATIONS

PART COUNTS

POST CAP

SIGN POST

PNL.1

FP_1

PNL.5

PNL.4

FP_5

FP_7

FP_S

2

2

1

4

1

1

2

2

4

2

2

2

8

2

2

4

0

4

CONFIGURATION 1:

SINGLE SIDED

DOUBLE SIDED

A

B

C

D

E

F

G

H

I

*

* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.

For specification and ordering purposes, contact EMS Delaware;

231 Executive Drive Suite 11

Newark, DE 19702 USA

Toll Free: 800-863-1496

Local Phone: 302-391-1370

Fax: 302-391-1371

Website: www.EasternMetal.com

Email: [email protected]

PEDESTRIAN DIRECTIONAL

Helpful Hints

• Keep in mind the intuitive

path of the user when locat-

ing and specifying exterior

directional signs.

• Use only standard and

approved nomenclature

and abbreviations.

• Refer to all appropriate state

and local codes, as needed,

for sign compliance, includ-

ing, but not limited to zon-

ing, ADAAG, MUTCD, etc.

• Sign fabricator to provide

all relevant engineering

calculations and provide all

methods and materials

of construction in

shop drawings.

Guidelines

• Provide pedestrians with

sequential guidance

throughout the campus with

strategic placement and

programmed messaging.

• Reinforce the brand equity

in the built environment with

brand color on the header.

• Use as a single-sided or

double-sided sign. Message

standards apply to both sides

of sign. It is acceptable to

use a different configuration

on each side.

• Locate signs at key decision

points and at locations

of optimal line of sight

from public buildings and

campus core.

• Arrow order should be as

follows: Up (straight),

Left, Right.

• Do not rearrange panel order.

PARTS

2E.29

Questions? Please contact xxxxx

?

SECTION E: PEDESTRIAN WAYFINDING

Page 30: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

Lot XXAddress

1/8"

4"1"

2" m

in.

5'-2

"

eq.

6"eq

.

1'-4

"

3/4"2'-0"- graphic panel

3/4"

3 1/4" 1'-7" 3 1/4"

eq. 2'-1 1/2" eq.

2'-9 1/2"

3'-2

"1"

8"1'

-6"

grade line

A

CD

BG

CEF

CEF

G

G

E

F

HBA

g

PDR12 3/4” = 1’-0”

Plan Elevation-Single side Sign(double side panels shown dashed)

DR33: Configuration 1, 21/2” = 1’-0”

Back Elevation- Single side Sign

JK

JK

I

2E.30

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P1. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E PNL.5 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P2.

*Use one panel only for single sided sign.

F PNL.4 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P3.

*Use one panel only for single sided sign.

PDR14PEDESTRIAN DIRECTIONAL

Page 31: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

2E.31

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

This Page Intentionally Left Blank

G FP_5 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

H FP_7 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1. *Use only for single sided signs.

I FP_S 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

J Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

K Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

SECTION E: PEDESTRIAN WAYFINDING

PEDESTRIAN DIRECTIONAL

PDR14

Page 32: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

becomessign panel

Component Parts /Assembly

Finished Sign

C

A

O

D

B

FE

G

H

P

M

N

2E.32

DETAIL

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P1. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E PNL.5 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P2.

*Use one panel only for single sided sign.

F PNL.4 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P3.

*Use one panel only for single sided sign.

G FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

PDR14PEDESTRIAN DIRECTIONAL

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

Page 33: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

3'-2" panel length

3/4" 1 3/4" 3/4"

3 1/4"

1/8"typ.

2"

1/8"

typ

.

7/8"

4 1/

4"7/

8"

6"

1/8"7/8"

1/8"

1 1/8"

1/4"

pan

el e

xtru

sio

n v

arie

s-se

e el

evat

ion

s fo

r h

eig

ht

dim

ensi

on

s

1/4"

pan

el h

eig

ht

vari

es-

see

elev

atio

ns

for

hei

gh

t d

imen

sio

ns

4" a

bov

e fi

nis

hed

gra

de

Partial Horizontal Section 6” = 1’-0”

Vertical Section: Concrete Footerno scale

Plan Elevation at Sidewalkno scale

Panel Detail no scale

EF

EF

G

B

O

N

N

O

grade line grade line

B

K

L

M

J

J

K

L

at concrete sidewalk condition

Vertical Section: Concrete Footerno scale

at earth / grass condition

2E.33

DETAIL

Specifications

SECTION E: PEDESTRIAN WAYFINDING

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

H FP_7 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1. *Use only for single sided signs.

J Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

K Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

L Expansion Joint To accommodate concrete

expansion and contraction.

M Sand Compacted sand for con-

densation drainage per

engineering requirements.

N Attachment Bracket Rutgers owned custom ex-

truded bracket cut to match

height of aluminum plate.

Permanently mount to back

of plate.

*See post extrusion spec. information on Parts sheet.

O Sign Panel Plate 1/8” Thk. aluminum plate cut

to dimensions shown

in elevations.

PEDESTRIAN DIRECTIONAL

PDR14

Page 34: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Up to TwoLine Message

Up to TwoLine Message

Up to TwoLine Message

Up to TwoLine Message

Up to TwoLine Message

Up to TwoLine Message

alig

n

Lot XXAddress

PNL.4 (max. message)1” = 1’-0”

AB

CL

C L -

typ

.

B

d

C

a

PNL.3 (max. message)1” = 1’-0”

C L

CL CL

3" 2 1/4" 1'-4 1/4"- max. copy length

3"2"

-ty

p.

4"-

typ

.

1 1/

4"1

1/4"

1 1/

4"

3" 2 5/8" 1 1/2"1'-2 1/2"-

max. copy length

3 3/

16"

2"

2E.34

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.34

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

GRAPHIC LAYOUTS

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A Copy 1 1/4” X-cap Height.

Type: T2. Tracking: +50.

Apply to front surface

of panel.

Applied Vinyl: V2.

B Arrow_Symbol.eps 1 3/4” Height.

Artwork provided by client.

Apply to front surface

of panel.

Applied Vinyl: V2. Rotate arrow around object

center-point.

C Copy 1 1/4” X-cap Height.

Type: T1. Tracking: +50.

Apply to front surface

of panel.

Applied Vinyl: V2.

D Parking_Symbol.eps 1 1/2” Height.

Artwork provided by client.

Apply to front surface

of panel.

Applied Vinyl: V2, V1.

PDR14PEDESTRIAN DIRECTIONAL

Page 35: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Visitors Must UseMain Entrance

University BehavioralHealth Care

No more than SIX messagesper sign.

ONLY includeparking messageson parking panels

No more than THREE lines per message.

Panels must MATCH the 18’’baseline.

Do NOT rearrangepanels.

MessageMessage

MessageMessage

Message

Message

Message

Message

Message

MessageMessage

Lot XXAddress

MessageMessageMessageMessageMessage

Lot XXAddress

Lot XXAddress

Lot XXAddress

Lot XXAddress

Lot XXAddress

Lot XXAddress

Lot XXAddress

Lot XXAddress

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

Lot XXAddress

E

PNL.2/PNL.3- Variation1” = 1’-0”

2 3/

8"1

5/8"

1"

MessageMessage

MessageMessage

MessageMessage

2E.35

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

2E.35

GRAPHIC DONT’S

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

E Secondary Copy 1” X-cap Height.

Type: T1. Tracking: +50.

Apply to front surface

of panel.

Applied Vinyl: V2.

GRAPHIC LAYOUTS

SECTION E: PEDESTRIAN WAYFINDING

PEDESTRIAN DIRECTIONAL

PDR14

Page 36: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

2E.36 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

This Page Intentionally Left Blank

Page 37: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Lot XX

Lot XX

Lot XX

Address

Address

Address

MessageMessage

MessageMessage

MessageMessageMessage

Lot XX

Lot XX

Address

Address

MessageMessage

MessageMessage

MessageMessageMessage

MessageMessage

Configuration 1 Configuration 2

17"

a

C

D

HB

E

G

F

I

J

Full length filler panels are used for single sided signs only. (not shown)

Stop panel below grade line. (not shown)

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR15

PART COUNTS

CONFIGURATIONS

PART COUNTS

POST CAP POST CAP

SIGN POST SIGN POST

PNL.1 PNL.1

FP_1 FP_1

PNL.2 PNL.3

PNL.5 PNL.5

FP_6 FP_6

FP_7 FP_7

FP_S FP_S

2 2

2 2

1 1

4 4

1 1

1 1

2 2

2 2

4 4

2 2

2 2

2 2

8 8

2 2

2 2

4 4

0 0

4 4

CONFIGURATION 1: CONFIGURATION 2:

SINGLE SIDED

SINGLE SIDED

DOUBLE SIDED

DOUBLE SIDED

A A

B B

C C

D D

E E

G G

H H

I I

J J

* *

* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.

For specification and ordering purposes, contact EMS Delaware;

231 Executive Drive Suite 11

Newark, DE 19702 USA

Toll Free: 800-863-1496

Local Phone: 302-391-1370

Fax: 302-391-1371

Website: www.EasternMetal.com

Email: [email protected]

PEDESTRIAN DIRECTIONAL

Helpful Hints

• Keep in mind the intuitive

path of the user when locat-

ing and specifying exterior

directional signs.

• Use only standard and

approved nomenclature

and abbreviations.

• Refer to all appropriate state

and local codes, as needed,

for sign compliance, includ-

ing, but not limited to zon-

ing, ADAAG, MUTCD, etc.

• Sign fabricator to provide

all relevant engineering

calculations and provide all

methods and materials

of construction in

shop drawings.

Guidelines

• Provide pedestrians with

sequential guidance

throughout the campus with

strategic placement and

programmed messaging.

• Reinforce the brand equity

in the built environment with

brand color on the header.

• Use as a single-sided or

double-sided sign. Message

standards apply to both sides

of sign. It is acceptable to

use a different configuration

on each side.

• Locate signs at key decision

points and at locations

of optimal line of sight

from public buildings and

campus core.

• Arrow order should be as

follows: Up (straight),

Left, Right.

• Do not rearrange panel order.

PARTS

2E.37

Questions? Please contact xxxxx

?

SECTION E: PEDESTRIAN WAYFINDING

Page 38: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Lot XX

Lot XX

Lot XX

Address

Address

Address

MessageMessage

MessageMessage

MessageMessageMessage

Lot XX

Lot XX

Address

Address

MessageMessage

MessageMessage

MessageMessageMessage

MessageMessage

eq.

6"eq

.

1'-4

"

3/4"2'-0"- graphic panel

3/4"

3 1/4" 1'-7" 3 1/4"

eq. 2'-1 1/2" eq.

2'-9 1/2"

1/8"

4"2"

min

.

5'-2

"

1"1'

-9"

1"8"

1"8"

2'-6

"

1"8"

1'-5

"

grade line

CEF

CEF

G

G

IBA

I

PDR11: Configuration 1 3/4” = 1’-0”

Plan Elevation-Single side Sign(double side panels shown dashed)

DR33: Configuration 1, 21/2” = 1’-0”

PDR11: Configuration 23/4” = 1’-0”

Back Elevation- Single side Sign(panel configurationvaries, 1 shown)

KL

KL

A

CD

D

D

BH

E

G

G

D

G

F

J

2E.38

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P1. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E PNL.2 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P2.

*Use one panel only for single sided sign.

F PNL.3 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P3.

*Use one panel only for single sided sign.

PDR15PEDESTRIAN DIRECTIONAL

Page 39: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

2E.39

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

This Page Intentionally Left Blank

G PNL.5 Painted aluminum panel

w/ applied vinyl graphics.

Custom extruded panel

attachment to be mounted

to back of panel w/ hi-bond

adhesive. Paint all sides: P3.

*Use one panel only for single sided sign.

H FP_6 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

I FP_7 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1. *Use only for single sided signs.

J FP_S 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

K Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

L Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

SECTION E: PEDESTRIAN WAYFINDING

PEDESTRIAN DIRECTIONAL

PDR15

Page 40: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

becomessign panel

Component Parts /Assembly

Finished Sign

C

A

O

D

B

EFG

H

I

P

M

N

2E.40

DETAIL

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post

cap, mechanically fastened

w/ tamper-resistant, span-

ner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P1. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E PNL.2 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P2.

*Use one panel only for single sided sign.

F PNL.3 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P3.

*Use one panel only for single sided sign.

PDR15PEDESTRIAN DIRECTIONAL

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

Page 41: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

3'-2" panel length

3/4" 1 3/4" 3/4"

3 1/4"

1/8"typ.

2"

1/8"

typ

.

7/8"

4 1/

4"7/

8"

6"

1/8"7/8"

1/8"

1 1/8"

1/4"

pan

el e

xtru

sio

n v

arie

s-se

e el

evat

ion

s fo

r h

eig

ht

dim

ensi

on

s

1/4"

pan

el h

eig

ht

vari

es-

see

elev

atio

ns

for

hei

gh

t d

imen

sio

ns

4" a

bov

e fi

nis

hed

gra

de

Partial Horizontal Section 6” = 1’-0”

Vertical Section: Concrete Footerno scale

Plan Elevation at Sidewalkno scale

Panel Detail no scale

EF

EF

G

B

P

O

O

P

grade line grade line

B

l

m

N

K

K

L

M

at concrete sidewalk condition

Vertical Section: Concrete Footerno scale

at earth / grass condition

2E.41

DETAIL

Specifications

SECTION E: PEDESTRIAN WAYFINDING

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

G PNL.5 Painted aluminum panel

w/ applied vinyl graphics.

Custom extruded panel

attachment to be mounted

to back of panel w/ hi-bond

adhesive. Paint all sides: P2.

*Use one panel only for single sided sign.

H FP_6 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

I FP_7 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1. *Use only for single sided signs.

K Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

L Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

M Expansion Joint To accommodate concrete

expansion and contraction.

N Sand Compacted sand for con-

densation drainage per

engineering requirements.

O Attachment Bracket Rutgers owned custom ex-

truded bracket cut to match

height of aluminum plate.

Permanently mount to back

of plate.

*See post extrusion spec. information on Parts sheet.

P Sign Panel Plate 1/8” Thk. aluminum plate

cut to dimensions shown in

elevations.

PEDESTRIAN DIRECTIONAL

PDR15

Page 42: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Up to TwoLine Message

Up to TwoLine Message

Up to TwoLine Message

Up to TwoLine Message

Up to TwoLine Message

Up to TwoLine Message

alig

n

Lot XXAddress

PNL.4 (max. message)1” = 1’-0”

AB

CL

C L -

typ

.

B

d

C

a

PNL.3 (max. message)1” = 1’-0”

C L

CL CL

3" 2 1/4" 1'-4 1/4"- max. copy length

3"2"

-ty

p.

4"-

typ

.

1 1/

4"1

1/4"

1 1/

4"

3" 2 5/8" 1 1/2"1'-2 1/2"-

max. copy length

3 3/

16"

2"

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

GRAPHIC LAYOUTS

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

2E.422E.42

A Copy 1 1/4” X-cap Height.

Type: T2. Tracking: +50.

Apply to front surface

of panel.

Applied Vinyl: V2.

B Arrow_Symbol.eps 1 3/4” Height.

Artwork provided by client.

Apply to front surface

of panel.

Applied Vinyl: V2. Rotate arrow around object

center-point.

C Copy 1 1/4” X-cap Height.

Type: T1. Tracking: +50.

Apply to front surface

of panel.

Applied Vinyl: V2.

D Parking_Symbol.eps 1 1/2” Height.

Artwork provided by client.

Apply to front surface

of panel.

Applied Vinyl: V2, V1.

PDR15PEDESTRIAN DIRECTIONAL

Page 43: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Visitors Must UseMain Entrance

University BehavioralHealth Care

No more than SIX messagesper sign.

ONLY includeparking messageson parking panels

No more than THREE lines per message.

Panels must MATCH the 17’’baseline.

Do NOT rearrangepanels.

Lot XX

Lot XX

Address

Address

MessageMessageMessage

MessageMessage

MessageMessage

Lot XX

Lot XX

Lot XX

Address

Address

Address

MessageMessage

MessageMessage

MessageMessageMessage

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

MessageMessage

Lot XXAddress

Lot XX

Lot XX

Address

Address

MessageMessageMessageMessageMessageMessage

MessageMessage

MessageMessage

Lot XX

Lot XX

Address

Address

Lot XXAddress

Lot XXAddress

Lot XXAddressLot XXAddress

Lot XXAddress

E

PNL.2/PNL.3- Variation1” = 1’-0”

2 3/

8"1

5/8"

1"

2E.43

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

2E.43

GRAPHIC DONT’S

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

E Secondary Copy 1” X-cap Height.

Type: T1. Tracking: +50.

Apply to front surface

of panel.

Applied Vinyl: V2.

GRAPHIC LAYOUTS

SECTION E: PEDESTRIAN WAYFINDING

PEDESTRIAN DIRECTIONAL

PDR15

Page 44: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

2E.442E.44 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

This Page Intentionally Left Blank

Page 45: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

SUB-SECTION

SECTION E:

PDR20 SERIES

Page 46: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

2E.46 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

PDR20 Series – Directional with Map

PDR21Config. 2

PDR22 PDR23Config. 1

PDR21Config. 1

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessageMessage

Lot XXAddress

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

PDR23Config. 2

PDR24Config. 2

PDR25Config. 2

PDR25Config. 1

Lot XXAddress

MessageMessage

MessageMessage

MessageMessage

MessageMessageMessage

Lot XXAddress

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

Lot XXAddress

Lot XXAddress

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

Lot XXAddress

Lot XXAddress

MessageMessage

MessageMessage

MessageMessage

MessageMessageMessage

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

1 MSG 2 MSG 3 MSG 4 MSG 5 MSG 6 MSG4 MSG

+ 1 PARK

4 MSG

+ 2 PARK

3 MSG

+ 3 PARK

3 MSG

+ 1 PARK

3 MSG

+ 2 PARK

3 ARROW N/A N/A N/A N/A N/A N/A N/A

PDR225 ARROW N/A N/A N/A N/AN/AN/AN/AN/A

4 ARROW N/A N/A N/AN/A N/AN/AN/AN/A N/A

PDR226 ARROW N/A N/A N/A N/A N/A N/A N/A N/A

2 ARROW N/A N/A N/A N/A N/A N/A

N/A N/A N/A

N/A N/A N/A N/A

1 ARROW N/APDR21

Config. 2

PDR21Config. 2

N/A N/A N/A N/A N/A N/A N/A N/A N/A

PDR20 SERIES:

PDR21Config. 2

PDR21Config. 2

PDR21Config. 1

PDR23Config. 1

PDR25Config. 2

PDR25Config. 1

PDR25Config. 2

PDR23Config. 2

PDR24Config. 2

PDR20 Series Overview

Recommended sign type

configurations shown.

Additional module

configurations must be

approved by Rutgers

University Environmental

Graphics Coordinator &

or Department of Facilities,

Planning and Development.

Below are the following steps for

selecting the correct pedestrian

directional for your needs.

A. Determine the number of

messages and parking messages

you require. Verify “heads up”

map orientation and artwork per

sign placement.

B. Determine message lengths

and character (letter) counts for

each message. Are your

messages 1, 2 or 3 lines long?

C. Select from the typical module

heights based on previous steps.

See graphic layout pages for

sample typographic layouts and

map artwork guidelines.

.

D. Review graphic dont’s to

ensure proper selection.

Sign Selection Process

Page 47: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

MessageMessage

MessageMessage

MessageMessage

MessageMessageMessage

Configuration 1 Configuration 2

27"

a

C

D

B

E

F

E

G Structural attachment angle (not shown)

Full length filler panels are used for single sided signs only. (not shown)

Stop panel below grade line. (not shown)

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR21

* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.

For specification and ordering purposes, contact EMS Delaware;

231 Executive Drive Suite 11

Newark, DE 19702 USA

Toll Free: 800-863-1496

Local Phone: 302-391-1370

Fax: 302-391-1371

Website: www.EasternMetal.com

Email: [email protected]

CONFIGURATIONS

DIRECTIONAL WITH MAP

Helpful Hints

• Keep in mind the intuitive path of

the user when locating and spec-

ifying exterior directional signs.

• Use only standard and

approved nomenclature

and abbreviations.

• Refer to all appropriate state

and local codes, as needed, for

sign compliance, including, but

not limited to zoning, ADAAG,

MUTCD, etc.

• Sign fabricator to provide

all relevant engineering calcu-

lations and provide all methods

and materials of construction in

shop drawings

Guidelines

• Provide pedestrians with sequential

guidance throughout the campus

with strategic placement and

programmed messaging.

• Reinforce the brand equity in the

built environment with brand color

on the header.

• Use as a single-sided or

double-sided sign. Message

standards apply to both sides

of sign. It is acceptable to use

a different configuration on

each side.

• Locate signs at key decision points

and at locations of optimal line of

sight from public buildings and

campus core.

• Arrow order should be as follows:

Up (straight), Left, Right.

• Do not rearrange panel order.

• Map orientation to match view of

pedestrian when standing at the

sign. What is shown ahead of you

on the map should appear ahead

of you.

• Contact Rutgers University

Environmental Graphics

Coordinator and or Department

of Facilities, Planning and

Development for correct

map artwork.

PART COUNTS

POST CAP POST CAP

SIGN POST SIGN POST

PNL.1 PNL.1

FP_1 FP_1

PNL.2 PNL.3

PNL.4

FP_2

FP_2

FP_3

FP_3

FP_S

FP_S

2 2

2 2

1 1

6 6

1 1

1

2

2

2

2

4

4

2 2

2 2

2 2

10 10

2 2

2

4

4

0

0

4

4

CONFIGURATION 1: CONFIGURATION 2:

SINGLE SIDED

SINGLE SIDED

DOUBLE SIDED

DOUBLE SIDED

A A

B B

C C

D D

E E

G H

H

I

I

J

J

* *

PARTS

2E.47

Questions? Please contact xxxxx

?

SECTION E: PEDESTRIAN WAYFINDING

Page 48: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

4"6"

4"

1'-4

"

2'-0"- graphic panel3/4"

1'-9 1/2" 3 1/4"

See PDR11, Configuration 1 forsign components, details

and graphic layouts.

See PDR11, Configuration 1 forsign components, details

and graphic layouts.

2" m

in.

2'-3

"2'

-6"

4'-9

"

1/8"

4" 4'-1 3/4" 4"

4'-9 3/4"

aligns to top of panel

aligns to bottomof panel

grade line

A

BD

CG

C

C

BA

F

E

PDR21: Configuration 1 3/4” = 1’-0”

Plan Elevation-Single side Sign(double side panels shown dashed)

See PDR11Configuration 1for sign components, details and graphic layouts.

PDR21: Configuration 1, 21/2” = 1’-0”

GI

GH

2E.48

ELEVATION

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

PDR21DIRECTIONAL WITH MAP

Page 49: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

This Page Intentionally Left Blank

2E.49

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

F FP_S 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

G Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

H Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

SECTION E: PEDESTRIAN WAYFINDING

DIRECTIONAL WITH MAP

PDR21

Page 50: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

becomessign panel

Component Parts /Assembly

Finished Sign

C

A

O

D

B

EFG

H

I

P

M

N

2E.50

DETAIL

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

PDR21

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

DIRECTIONAL WITH MAP

Page 51: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

3'-2" panel length

3/4" 1 3/4" 3/4"

3 1/4"

1/8"typ.

2"

1/8"

typ

.

7/8"

4 1/

4"7/

8"

6"

1/8"7/8"

1/8"

1 1/8"

1/4"

pan

el e

xtru

sio

n v

arie

s-se

e el

evat

ion

s fo

r h

eig

ht

dim

ensi

on

s

1/4"

pan

el h

eig

ht

vari

es-

see

elev

atio

ns

for

hei

gh

t d

imen

sio

ns

4" a

bov

e fi

nis

hed

gra

de

Partial Horizontal Section 6” = 1’-0”

Vertical Section: Concrete Footerno scale

Plan Elevation at Sidewalkno scale

Panel Detail no scale

EFG

FE

G

G

B

P

O

O

P

grade line grade line

B

L

M

N

H

K

L

M

at concrete sidewalk condition

Vertical Section: Concrete Footerno scale

at earth / grass condition

2E.51

DETAIL

Specifications

SECTION E: PEDESTRIAN WAYFINDING

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR21

H Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

I Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

J Expansion Joint To accommodate concrete

expansion and contraction.

K Sand Compacted sand for con-

densation drainage per

engineering requirements.

L Attachment Bracket Rutgers owned custom ex-

truded bracket cut to match

height of aluminum plate.

Permanently mount to back

of plate.

*See post extrusion spec. information on Parts sheet.

M Sign Panel Plate 1/8” Thk. aluminum plate

cut to dimensions shown in

elevations.

DIRECTIONAL WITH MAP

Page 52: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

a

PNL.11” = 1’-0”

GRAPHIC FOR

PLACEMENT ONLY

2E.52

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.52

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

GRAPHIC LAYOUTS

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4. *Use one panel only for single sided sign.

DIRECTIONAL WITH MAP

PDR21

Page 53: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

27"

a

C

D

B

E

F

E

G Structural attachment angle (not shown)

Full length filler panels are used for single sided signs only. (not shown)

Stop panel below grade line. (not shown)

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR22

* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.

For specification and ordering purposes, contact EMS Delaware;

231 Executive Drive Suite 11

Newark, DE 19702 USA

Toll Free: 800-863-1496

Local Phone: 302-391-1370

Fax: 302-391-1371

Website: www.EasternMetal.com

Email: [email protected]

CONFIGURATIONS

Helpful Hints

• Keep in mind the intuitive path of

the user when locating and spec-

ifying exterior directional signs.

• Use only standard and

approved nomenclature

and abbreviations.

• Refer to all appropriate state

and local codes, as needed, for

sign compliance, including, but

not limited to zoning, ADAAG,

MUTCD, etc.

• Sign fabricator to provide

all relevant engineering calcu-

lations and provide all methods

and materials of construction in

shop drawings

Guidelines

• Provide pedestrians with sequential

guidance throughout the campus

with strategic placement and

programmed messaging.

• Reinforce the brand equity in the

built environment with brand color

on the header.

• Use as a single-sided or

double-sided sign. Message

standards apply to both sides

of sign. It is acceptable to use

a different configuration on

each side.

• Locate signs at key decision points

and at locations of optimal line of

sight from public buildings and

campus core.

• Arrow order should be as follows:

Up (straight), Left, Right.

• Do not rearrange panel order.

• Map orientation to match view of

pedestrian when standing at the

sign. What is shown ahead of you

on the map should appear ahead

of you.

• Contact Rutgers University

Environmental Graphics

Coordinator and or Department

of Facilities, Planning and

Development for correct

map artwork.

PART COUNTS

POST CAP

SIGN POST

PNL.1

FP_1

PNL.5

FP_2

FP_7

FP_S

2

2

1

2

1

2

2

4

2

2

2

4

2

4

0

4

CONFIGURATION 1:

SINGLE SIDED

DOUBLE SIDED

A

B

C

D

E

F

G

H

*

PARTS

DIRECTIONAL WITH MAP

2E.53

Questions? Please contact xxxxx

?

SECTION E: PEDESTRIAN WAYFINDING

Page 54: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

4"6"

4"

1'-4

"2'-0"- graphic panel

3/4"

1'-9 1/2" 3 1/4"

See PDR12, Configuration 1 forsign components, details

and graphic layouts.

See PDR11, Configuration 1 forsign components, details

and graphic layouts.

2" m

in.

2'-3

"3'

-2"

5'-5

"

1/8"

4" 4'-1 3/4" 4"

4'-9 3/4"

aligns to top of panel

aligns to bottomof panel

grade line

A

BD

CG

C

C

BA

F

E

PDR22: Configuration 1 3/4” = 1’-0”

Plan Elevation-Single side Sign(double side panels shown dashed)

See PDR11Configuration 1for sign components, details and graphic layouts.

PDR22: Configuration 1, 21/2” = 1’-0”

GI

GH

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

2E.54

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

DIRECTIONAL WITH MAP

PDR22

Page 55: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

This Page Intentionally Left Blank

2E.55

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

F FP_S 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

G Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

H Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

SECTION E: PEDESTRIAN WAYFINDING

PDR22DIRECTIONAL WITH MAP

Page 56: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

1/8"7/8"

1/8"

1 1/8"

1/4"

pan

el e

xtru

sio

n v

arie

s-se

e el

evat

ion

s fo

r h

eig

ht

dim

ensi

on

s

1/4"

pan

el h

eig

ht

vari

es-

see

elev

atio

ns

for

hei

gh

t d

imen

sio

ns

be

co

me

ssi

gn

pa

ne

l

Component Parts /Assembly

Finished Sign

Panel Detail no scale

CL

M

A

M

B

C

D

E

N

M

N

G

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

2E.56

DETAIL

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR22

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

DIRECTIONAL WITH MAP

Page 57: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

PDRPedestrian

Directional-see various

layouts,sheet 3.17.

4" a

bov

e fi

nis

hed

gra

de

2'-0"- graphic panel

3/4" 1 3/4" 3/4"

3 1/4"

7/8"

4 1/

4"7/

8"

6"

1/8"

typ

.

1/8"typ

2"

Partial Horizontal Section 3” = 1’-0”

Vertical Section: Concrete Footerno scale

Plan Elevation at Sidewalkno scale

C

L

M

g

grade line grade line

B

I

J

H

K

B

C

H

I

J

at concrete sidewalk condition

Vertical Section: Concrete Footerno scale

at earth / grass condition

2E.57

DETAIL

Specifications

SECTION E: PEDESTRIAN WAYFINDING

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR22

H Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

I Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

J Expansion Joint To accommodate concrete

expansion and contraction.

K Sand Compacted sand for con-

densation drainage per

engineering requirements.

L Attachment Bracket Rutgers owned custom ex-

truded bracket cut to match

height of aluminum plate.

Permanently mount to back

of plate.

*See post extrusion spec. information on Parts sheet.

M Sign Panel Plate 1/8” Thk. aluminum plate cut

to dimensions shown

in elevations.

DIRECTIONAL WITH MAP

Page 58: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

a

PNL21” = 1’-0”

2E.58

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.58

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

GRAPHIC LAYOUTS

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4. *Use one panel only for single sided sign.

GRAPHIC FOR

PLACEMENT ONLY

PDR22DIRECTIONAL WITH MAP

Page 59: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

2E.59

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

2E.59

GRAPHIC DONT’S

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

SECTION E: PEDESTRIAN WAYFINDING

PDR22

This Page Intentionally Left Blank

DIRECTIONAL WITH MAP

Page 60: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

2E.60 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

This Page Intentionally Left Blank

Page 61: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Lot XX

Lot XX

Address

Address

MessageMessage

MessageMessage

MessageMessageMessage

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Lot XXAddress

MessageMessage

MessageMessage

MessageMessageMessage

MessageMessage

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Configuration 1 Configuration 2

26"

a

C

D

B

E

F

E

G Structural attachment angle (not shown)

Full length filler panels are used for single sided signs only. (not shown)

Stop panel below grade line. (not shown)

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR23

* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.

For specification and ordering purposes, contact EMS Delaware;

231 Executive Drive Suite 11

Newark, DE 19702 USA

Toll Free: 800-863-1496

Local Phone: 302-391-1370

Fax: 302-391-1371

Website: www.EasternMetal.com

Email: [email protected]

CONFIGURATIONS

Helpful Hints

• Keep in mind the intuitive path of

the user when locating and spec-

ifying exterior directional signs.

• Use only standard and

approved nomenclature

and abbreviations.

• Refer to all appropriate state

and local codes, as needed, for

sign compliance, including, but

not limited to zoning, ADAAG,

MUTCD, etc.

• Sign fabricator to provide

all relevant engineering calcu-

lations and provide all methods

and materials of construction in

shop drawings

Guidelines

• Provide pedestrians with sequential

guidance throughout the campus

with strategic placement and

programmed messaging.

• Reinforce the brand equity in the

built environment with brand color

on the header.

• Use as a single-sided or

double-sided sign. Message

standards apply to both sides

of sign. It is acceptable to use

a different configuration on

each side.

• Locate signs at key decision points

and at locations of optimal line of

sight from public buildings and

campus core.

• Arrow order should be as follows:

Up (straight), Left, Right.

• Do not rearrange panel order.

• Map orientation to match view of

pedestrian when standing at the

sign. What is shown ahead of you

on the map should appear ahead

of you.

• Contact Rutgers University

Environmental Graphics

Coordinator and or Department

of Facilities, Planning and

Development for correct

map artwork.

PART COUNTS

POST CAP POST CAP

SIGN POST SIGN POST

PNL.1 PNL.1

FP_1 FP_1

PNL.2 PNL.3

PNL.4

FP_2

FP_2

FP_3

FP_3

FP_S

FP_S

2 2

2 2

1 1

6 6

1 1

1

2

2

2

2

4

4

2 2

2 2

2 2

10 10

2 2

2

4

4

0

0

4

4

CONFIGURATION 1: CONFIGURATION 2:

SINGLE SIDED

SINGLE SIDED

DOUBLE SIDED

DOUBLE SIDED

A A

B B

C C

D D

E E

G H

H

I

I

J

J

* *

PARTS

DIRECTIONAL WITH MAP

2E.61

Questions? Please contact xxxxx

?

SECTION E: PEDESTRIAN WAYFINDING

Page 62: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Lot XX

Lot XX

Address

Address

MessageMessage

MessageMessage

MessageMessageMessage

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

4"6"

4"

1'-4

"

2'-0"- graphic panel3/4"

1'-9 1/2" 3 1/4"

See PDR11, Configuration 1 forsign components, details

and graphic layouts.

4" 4'-1 3/4" 4"

4'-9 3/4"

See PDR11, Configuration 1 forsign components, details

and graphic layouts.

2" m

in.

2'-2

"3'

-3"

5'-5

"

1/8"

aligns to top of panel

aligns to bottomof panel

CG

C

BA

E

PDR23: Configuration 1 3/4” = 1’-0”

Plan Elevation-Single side Sign(double side panels shown dashed)

PDR23z: Configuration 1, 21/2” = 1’-0”

GH

See PDR11Configuration 1for sign components, details and graphic layouts.

grade line

A

BD

C

F

GI

2E.62

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

F FP_S 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

G Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to con-

form to engineering require-

ments and appropriate wind-

loads for individual structure.

Footer to be Below grade and

landscaping, by others, where

necessary.

H Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square, pour

footer below sidewalk and

repour sidewalk square.

PDR23DIRECTIONAL WITH MAP

Page 63: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

This Page Intentionally Left Blank

2E.63

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

SECTION E: PEDESTRIAN WAYFINDING

PDR23DIRECTIONAL WITH MAP

Page 64: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

1/8"7/8"

1/8"

1 1/8"

1/4"

pan

el e

xtru

sio

n v

arie

s-se

e el

evat

ion

s fo

r h

eig

ht

dim

ensi

on

s

1/4"

pan

el h

eig

ht

vari

es-

see

elev

atio

ns

for

hei

gh

t d

imen

sio

ns

be

co

me

ssi

gn

pa

ne

l

Component Parts /Assembly

Finished Sign

Panel Detail no scale

CL

M

A

M

B

C

D

E

N

M

N

G

2E.64

DETAIL

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR23

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4

*Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

DIRECTIONAL WITH MAP

Page 65: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

PDRPedestrian

Directional-see various

layouts,sheet 3.17.

4" a

bov

e fi

nis

hed

gra

de

2'-0"- graphic panel

3/4" 1 3/4" 3/4"

3 1/4"

7/8"

4 1/

4"7/

8"

6"

1/8"

typ

.

1/8"typ

2"

Partial Horizontal Section 3” = 1’-0”

Vertical Section: Concrete Footerno scale

Plan Elevation at Sidewalkno scale

C

L

M

g

grade line grade line

B

I

J

H

K

B

C

H

I

J

at concrete sidewalk condition

Vertical Section: Concrete Footerno scale

at earth / grass condition

2E.65

DETAIL

Specifications

SECTION E: PEDESTRIAN WAYFINDING

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR23

H Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

I Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

J Expansion Joint To accommodate concrete

expansion and contraction.

K Sand Compacted sand for con-

densation drainage per

engineering requirements.

L Attachment Bracket Rutgers owned custom ex-

truded bracket cut to match

height of aluminum plate.

Permanently mount to back

of plate.

*See post extrusion spec. information on Parts sheet.

M Sign Panel Plate 1/8” Thk. aluminum plate cut

to dimensions shown

in elevations.

DIRECTIONAL WITH MAP

Page 66: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

a

PNL21” = 1’-0”

GRAPHIC FOR

PLACEMENT ONLY

2E.66

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.66

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

A PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4. *Use one panel only for single sided sign.

PDR23

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

DIRECTIONAL WITH MAP

Page 67: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

Lot XXAddress

27"

a

C

D

B

E

F

E

G Structural attachment angle (not shown)

Full length filler panels are used for single sided signs only. (not shown)

Stop panel below grade line. (not shown)

Configuration 1

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR24

* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.

For specification and ordering purposes, contact EMS Delaware;

231 Executive Drive Suite 11

Newark, DE 19702 USA

Toll Free: 800-863-1496

Local Phone: 302-391-1370

Fax: 302-391-1371

Website: www.EasternMetal.com

Email: [email protected]

CONFIGURATIONS

Helpful Hints

• Keep in mind the intuitive path of

the user when locating and spec-

ifying exterior directional signs.

• Use only standard and

approved nomenclature

and abbreviations.

• Refer to all appropriate state

and local codes, as needed, for

sign compliance, including, but

not limited to zoning, ADAAG,

MUTCD, etc.

• Sign fabricator to provide

all relevant engineering calcu-

lations and provide all methods

and materials of construction in

shop drawings

Guidelines

• Provide pedestrians with sequential

guidance throughout the campus

with strategic placement and

programmed messaging.

• Reinforce the brand equity in the

built environment with brand color

on the header.

• Use as a single-sided or

double-sided sign. Message

standards apply to both sides

of sign. It is acceptable to use

a different configuration on

each side.

• Locate signs at key decision points

and at locations of optimal line of

sight from public buildings and

campus core.

• Arrow order should be as follows:

Up (straight), Left, Right.

• Do not rearrange panel order.

• Map orientation to match view of

pedestrian when standing at the

sign. What is shown ahead of you

on the map should appear ahead

of you.

• Contact Rutgers University

Environmental Graphics

Coordinator and or Department

of Facilities, Planning and

Development for correct

map artwork.

PART COUNTSPART COUNTS

POST CAP

SIGN POST

PNL.1

FP_1

PNL.5

PNL.4

FP_5

FP_7

FP_S

2

2

1

6

1

1

2

2

4

2

2

2

10

2

2

4

0

4

CONFIGURATION 1:

SINGLE SIDED

DOUBLE SIDED

A

B

C

D

E

F

G

H

I

*

PARTS

DIRECTIONAL WITH MAP

2E.67

Questions? Please contact xxxxx

?

SECTION E: PEDESTRIAN WAYFINDING

Page 68: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

MessageMessage

Lot XXAddress

4"6"

4"

1'-4

"2'-0"- graphic panel

3/4"

1'-9 1/2" 3 1/4"

See PDR12, Configuration 1 forsign components, details

and graphic layouts.

See PDR11, Configuration 1 forsign components, details

and graphic layouts.

2" m

in.

2'-3

"3'

-2"

5'-5

"

1/8"

4" 4'-1 3/4" 4"

4'-9 3/4"

aligns to top of panel

aligns to bottomof panel

grade line

A

BD

CG

C

C

BA

F

E

PDR243/4” = 1’-0”

Plan Elevation-Single side Sign(double side panels shown dashed)

PDR241/2” = 1’-0”

GI

GH

See PDR11Configuration 1for sign components, details and graphic layouts.

2E.68

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post

cap, mechanically fastened

w/ tamper-resistant, span-

ner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

PDR24DIRECTIONAL WITH MAP

Page 69: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

This Page Intentionally Left Blank

2E.69

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

F FP_S 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

G Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

H Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

SECTION E: PEDESTRIAN WAYFINDING

PDR24DIRECTIONAL WITH MAP

Page 70: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

1/8"7/8"

1/8"

1 1/8"

1/4"

pan

el e

xtru

sio

n v

arie

s-se

e el

evat

ion

s fo

r h

eig

ht

dim

ensi

on

s

1/4"

pan

el h

eig

ht

vari

es-

see

elev

atio

ns

for

hei

gh

t d

imen

sio

ns

be

co

me

ssi

gn

pa

ne

l

Component Parts /Assembly

Finished Sign

Panel Detail no scale

CL

M

A

M

B

C

D

E

N

M

N

G

2E.70

DETAIL

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR24

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

DIRECTIONAL WITH MAP

Page 71: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

PDRPedestrian

Directional-see various

layouts,sheet 3.17.

4" a

bov

e fi

nis

hed

gra

de

2'-0"- graphic panel

3/4" 1 3/4" 3/4"

3 1/4"

7/8"

4 1/

4"7/

8"

6"

1/8"

typ

.

1/8"typ

2"

Partial Horizontal Section 3” = 1’-0”

Vertical Section: Concrete Footerno scale

Plan Elevation at Sidewalkno scale

C

L

M

g

grade line grade line

B

I

J

H

K

B

C

H

I

J

at concrete sidewalk condition

Vertical Section: Concrete Footerno scale

at earth / grass condition

2E.71

DETAIL

Specifications

SECTION E: PEDESTRIAN WAYFINDING

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR24

H Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

I Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

J Expansion Joint To accommodate concrete

expansion and contraction.

K Sand Compacted sand for con-

densation drainage per

engineering requirements.

L Attachment Bracket Rutgers owned custom ex-

truded bracket cut to match

height of aluminum plate.

Permanently mount to back

of plate.

*See post extrusion spec. information on Parts sheet.

M Sign Panel Plate 1/8” Thk. aluminum plate cut

to dimensions shown

in elevations.

DIRECTIONAL WITH MAP

Page 72: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

a

PNL21” = 1’-0”

2E.72

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.72

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

GRAPHIC LAYOUTS

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4. *Use one panel only for single sided sign.

GRAPHIC FOR

PLACEMENT ONLY

DIRECTIONAL WITH MAP

PDR24

Page 73: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Lot XX

Lot XX

Address

Address

MessageMessage

MessageMessage

MessageMessageMessage

MessageMessage

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental SchLot XX

Lot XX

Lot XX

Address

Address

Address

MessageMessage

MessageMessage

MessageMessageMessage

Configuration 1 Configuration 2

26"

a

C

D

B

E

F

E

G Structural attachment angle (not shown)

Full length filler panels are used for single sided signs only. (not shown)

Stop panel below grade line. (not shown)

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR25

* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.

For specification and ordering purposes, contact EMS Delaware;

231 Executive Drive Suite 11

Newark, DE 19702 USA

Toll Free: 800-863-1496

Local Phone: 302-391-1370

Fax: 302-391-1371

Website: www.EasternMetal.com

Email: [email protected]

CONFIGURATIONS

Helpful Hints

• Keep in mind the intuitive path of

the user when locating and spec-

ifying exterior directional signs.

• Use only standard and

approved nomenclature

and abbreviations.

• Refer to all appropriate state

and local codes, as needed, for

sign compliance, including, but

not limited to zoning, ADAAG,

MUTCD, etc.

• Sign fabricator to provide

all relevant engineering calcu-

lations and provide all methods

and materials of construction in

shop drawings

Guidelines

• Provide pedestrians with sequential

guidance throughout the campus

with strategic placement and

programmed messaging.

• Reinforce the brand equity in the

built environment with brand color

on the header.

• Use as a single-sided or

double-sided sign. Message

standards apply to both sides

of sign. It is acceptable to use

a different configuration on

each side.

• Locate signs at key decision points

and at locations of optimal line of

sight from public buildings and

campus core.

• Arrow order should be as follows:

Up (straight), Left, Right.

• Do not rearrange panel order.

• Map orientation to match view of

pedestrian when standing at the

sign. What is shown ahead of you

on the map should appear ahead

of you.

• Contact Rutgers University

Environmental Graphics

Coordinator and or Department

of Facilities, Planning and

Development for correct

map artwork.

PART COUNTSPART COUNTS

POST CAP POST CAP

SIGN POST SIGN POST

PNL.1 PNL.1

FP_1 FP_1

PNL.2 PNL.3

PNL.5 PNL.5

FP_6 FP_6

FP_7 FP_7

FP_S FP_S

2 2

2 2

1 1

6 6

1 1

1 1

2 2

2 2

4 4

2 2

2 2

2 2

10 10

2 2

2 2

4 4

0 0

4 4

CONFIGURATION 1: CONFIGURATION 2:

SINGLE SIDED

SINGLE SIDED

DOUBLE SIDED

DOUBLE SIDED

A A

B B

C C

D D

E E

G G

H H

I I

J J

* *

PARTS

DIRECTIONAL WITH MAP

2E.73

Questions? Please contact xxxxx

?

SECTION E: PEDESTRIAN WAYFINDING

Page 74: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental SchLot XX

Lot XX

Lot XX

Address

Address

Address

MessageMessage

MessageMessage

MessageMessageMessage

4"6"

4"

1'-4

"2'-0"- graphic panel

3/4"

1'-9 1/2" 3 1/4"

See PDR11, Configuration 1 forsign components, details

and graphic layouts.

4" 4'-1 3/4" 4"

4'-9 3/4"

2" m

in.

2'-2

"3'

-3"

5'-5

"

1/8"

aligns to top of panel

aligns to bottomof panel

See PDR11, Configuration 1 forsign components, details

and graphic layouts.

CG

C

BA

E

PDR23: Configuration 1 3/4” = 1’-0”

Plan Elevation-Single side Sign(double side panels shown dashed)

PDR23z: Configuration 1, 21/2” = 1’-0”

GH

grade line

A

BD

C

F

GI

See PDR11Configuration 1for sign components, details and graphic layouts.

2E.74

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

EFP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

DIRECTIONAL WITH MAP

PDR25

Page 75: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

This Page Intentionally Left Blank

2E.75

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

F FP_S 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

G Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

H Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

SECTION E: PEDESTRIAN WAYFINDING

PDR25DIRECTIONAL WITH MAP

Page 76: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

1/8"7/8"

1/8"

1 1/8"

1/4"

pan

el e

xtru

sio

n v

arie

s-se

e el

evat

ion

s fo

r h

eig

ht

dim

ensi

on

s

1/4"

pan

el h

eig

ht

vari

es-

see

elev

atio

ns

for

hei

gh

t d

imen

sio

ns

be

co

me

ssi

gn

pa

ne

l

Component Parts /Assembly

Finished Sign

Panel Detail no scale

CL

M

A

M

B

C

D

E

N

M

N

G

2E.76

DETAIL

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR25

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4

*Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

DIRECTIONAL WITH MAP

Page 77: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

PDRPedestrian

Directional-see various

layouts,sheet 3.17.

4" a

bov

e fi

nis

hed

gra

de

2'-0"- graphic panel

3/4" 1 3/4" 3/4"

3 1/4"

7/8"

4 1/

4"7/

8"

6"

1/8"

typ

.

1/8"typ

2"

Partial Horizontal Section 3” = 1’-0”

Vertical Section: Concrete Footerno scale

Plan Elevation at Sidewalkno scale

C

L

M

g

grade line grade line

B

I

J

H

K

B

C

H

I

J

at concrete sidewalk condition

Vertical Section: Concrete Footerno scale

at earth / grass condition

2E.77

DETAIL

Specifications

SECTION E: PEDESTRIAN WAYFINDING

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

PDR25

H Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

I Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

J Expansion Joint To accommodate concrete

expansion and contraction.

K Sand Compacted sand for con-

densation drainage per

engineering requirements.

L Attachment Bracket Rutgers owned custom ex-

truded bracket cut to match

height of aluminum plate.

Permanently mount to back

of plate.

*See post extrusion spec. information on Parts sheet.

M Sign Panel Plate 1/8” Thk. aluminum plate

cut to dimensions shown in

elevations.

DIRECTIONAL WITH MAP

Page 78: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

PNL.31” = 1’-0”

a

2E.78

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.78

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4. *Use one panel only for single sided sign.

GRAPHIC LAYOUTS

GRAPHIC FOR

PLACEMENT ONLY

PDR25DIRECTIONAL WITH MAP

Page 79: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

This Page Intentionally Left Blank

2E.79

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

2E.79

GRAPHIC DONT’S

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

SECTION E: PEDESTRIAN WAYFINDING

PDR25DIRECTIONAL WITH MAP

Page 80: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

This Page Intentionally Left Blank

2E.80 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

Page 81: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

SECTION E:

ORT10 SERIES

SUB-SECTION

Page 82: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.82

ORT10 Series – Orientation Map

ORT11

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

ORT10 Series Overview

Recommended sign type

configurations shown.

Additional module

configurations must be

approved by Rutgers

University Environmental

Graphics Coordinator &

or Department of Facilities,

Planning and Development.

Below are the following steps for

selecting the correct vehicular

directional for your needs.

A. Verify “heads up” map

orientation and artwork per sign

placement.

.

Sign Selection Process

Questions? Please contact xxxxx

?

Page 83: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

26"

a

C

D

G

B

E

I

H

Full length filler panels are used for single sided signs only. (not shown)

Stop panel below grade line. (not shown)

Configuration 1

* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.

For specification and ordering purposes, contact EMS Delaware;

231 Executive Drive Suite 11

Newark, DE 19702 USA

Toll Free: 800-863-1496

Local Phone: 302-391-1370

Fax: 302-391-1371

Website: www.EasternMetal.com

Email: [email protected]

2E.83

PARTS

CONFIGURATIONS

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

POST CAP

SIGN POST

DR_PNL.x

FP_1

DR_PNL.x

DR_PNL.x

FP_x

FP_x

FP_S

2

2

1

4

1

1

2

2

4

2

2

2

8

2

2

4

0

4

PART COUNTS

SINGLE SIDED

DOUBLE SIDED

A

B

C

D

E

F

G

I

J

*

SECTION E: PEDESTRIAN WAYFINDING

CONFIGURATION 1: CONFIGURATION 2:

ORIENTATION MAP

ORT11

Helpful Hints

• Keep in mind the intuitive

path of the user when locat-

ing and specifying exterior

directional signs.

• Use only standard and

approved nomenclature

and abbreviations.

• Refer to all appropriate state

and local codes, as needed,

for sign compliance, includ-

ing, but not limited to zon-

ing, ADAAG, MUTCD, etc.

• Sign fabricator to provide

all relevant engineering

calculations and provide all

methods and materials

of construction in

shop drawings.

Guidelines

• Provide pedestrians with a

visual guide of the campus.

• Reinforce the brand equity

in the built environment with

brand color on the header.

• Use as a single-sided or

double-sided sign. Message

standards apply to both

sides of sign.

• Map “heads up” orientation

to match view of pedestrian

when standing at the sign.

What is shown ahead of you

on the map should appear

ahead of you.

• Contact Rutgers

University Environmental

Graphics Coordinator and

or Department of Facilities,

Planning and Development

for correct map artwork.

Questions? Please contact xxxxx

?

Page 84: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

1/8"

4"1"

3'-3

"2'

-2"

2" m

in.

5'-1

0"

eq.

6"eq

.

1'-4

"

3/4"2'-0"- graphic panel

3/4"

3 1/4" 1'-7" 3 1/4"

eq. 2'-1 1/2" eq.

2'-9 1/2"

A

CD

E

E

GBA

G

ORT113/4” = 1’-0”

Plan Elevation-Single side Sign(double side panels shown dashed)

ORT11: Configuration 1, 21/2” = 1’-0”

Back Elevation- Single side Sign(panel configurationvaries, 1 shown)

IJ

grade line

BF

E

H

IJ

2E.84

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post

cap, mechanically fastened

w/ tamper-resistant, span-

ner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P1. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E PNL.2 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P2.

*Use one panel only for single sided sign.

F FP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

ORIENTATION MAP

ORT11

Page 85: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

This Page Intentionally Left Blank

2E.85

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

G FP_3 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1. *Use only for single sided signs.

H FP_S 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

I Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and

appropriate wind-loads for

individual structure. Footer

to be below grade and

landscaping, by others,

where necessary.

J Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

SECTION E: PEDESTRIAN WAYFINDING

ORT11ORIENTATION MAP

Page 86: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

becomessign panel

Component Parts /Assembly

Finished Sign

C

A

M

D

B

E

F

G

N

M

N

2E.86

DETAIL

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

A Post Cap 1/8” thk. Pre-punched and

painted aluminum post cap,

mechanically fastened w/

tamper-resistant,

spanner-head screws.

Paint all sides: P4.

B Sign Post Rutgers owned custom,

extruded sign post w/inset

grooves for ease of panel

install and removal.

Paint all sides: P4. All drilled holes to be weath-

er-proofed for water and

environmental considerations.

*See post extrusion spec. information on Parts sheet.

C PNL.1 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P1. *Use one panel only for single sided sign.

D FP_1 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

E PNL.2 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P2.

*Use one panel only for single sided sign.

FFP_2 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1.

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

ORT11ORIENTATION MAP

Page 87: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

3'-2" panel length

3/4" 1 3/4" 3/4"

3 1/4"

1/8"typ.

2"

1/8"

typ

.

7/8"

4 1/

4"7/

8"

6"

1/8"7/8"

1/8"

1 1/8"

1/4"

pan

el e

xtru

sio

n v

arie

s-se

e el

evat

ion

s fo

r h

eig

ht

dim

ensi

on

s

1/4"

pan

el h

eig

ht

vari

es-

see

elev

atio

ns

for

hei

gh

t d

imen

sio

ns

4" a

bov

e fi

nis

hed

gra

de

Partial Horizontal Section 6” = 1’-0”

Vertical Section: Concrete Footerno scale

Plan Elevation at Sidewalkno scale

Panel Detail no scale

E

E

G

B

n

m

m

n

grade line grade line

B

j

k

l

i

i

j

k

at concrete sidewalk condition

Vertical Section: Concrete Footerno scale

at earth / grass condition

2E.87

DETAIL

Specifications

SECTION E: PEDESTRIAN WAYFINDING

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

G FP_7 1/8” thk. Painted aluminum

filler panel.

Paint all sides: P1. *Use only for single sided signs.

I Concrete Footer / Pad Minimum 3’-0”d. concrete

footer. Each footer to

conform to engineering

requirements and appropri-

ate wind-loads for individual

structure. Footer to be Be-

low grade and landscaping,

by others, where necessary.

J Concrete Sidewalk If sign is located at sidewalk,

remove sidewalk square,

pour footer below sidewalk

and repour sidewalk square.

K Expansion Joint To accommodate concrete

expansion and contraction.

L Sand Compacted sand for con-

densation drainage per

engineering requirements.

M Attachment Bracket Rutgers owned custom ex-

truded bracket cut to match

height of aluminum plate.

Permanently mount to back

of plate.

*See post extrusion spec. information on Parts sheet.

N Sign Panel Plate 1/8” Thk. aluminum plate cut

to dimensions shown

in elevations.

ORT11ORIENTATION MAP

Page 88: SECTION E: PEDESTRIAN WAYFINDING - Rutgers University · 2020-01-23 · RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL For typography, finish/material and

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School

Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch

PNL.31” = 1’-0”

a

2E.88

ELEVATION

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

Specifications

RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.88

PARTS

ELEVATION

DETAIL

GRAPHIC LAYOUT

GRAPHIC LAYOUTS

For typography, finish/material and symbol specifications

refer to Manual Part 2, Section A: Graphic Standards.

A PNL.3 Painted aluminum panel w/

applied vinyl graphics. Cus-

tom extruded panel attach-

ment to be mounted to back

of panel w/ hi-bond adhesive.

Paint all sides: P4.

GRAPHIC FOR

PLACEMENT ONLY

ORT11ORIENTATION MAP