sectos sf load break switch - abb group...gas-low locking device or manual locking device as options...

21
© ABB Group October 30, 2014 | Slide 1 Sectos SF 6 Load Break Switch One ABB Surabaya, 30 th October 2014 Total Solution for Energy Efficiency and Improved Industrial Productivity

Upload: others

Post on 20-Jan-2020

28 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 1

Sectos SF6 Load Break Switch

One ABB Surabaya, 30th October 2014Total Solution for Energy Efficiency and Improved Industrial Productivity

Page 2: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 2

Sectos Load Breaking SwitchOverview

§ Sectos load breaking switch offers the following features:

§ Completely sealed stainless steel tank

§ 2-position(ON - OFF) or 3-position(ON - OFF - EARTH)§ Reliable spiral spring operation mechanism with light

reflecting and clear position indicator

§ Stable gas density switch with a temperaturecompensated gauge

§ Mechanical manual locking device or low gas lockingdevice

§ Multiple mounting modes

§ Complete feeder automation solutions§ Easily upgraded from manual to motor operation

Page 3: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 4

UnitedKingdom

NorwayFinland

SwedenLithuaniaPoland

HungarySlovenia

FranceSpain Croatia

Algeria

MoroccoIsrael

SaudiArabia

IranJordan

Tunisia

Egypt

India

China

ThailandVietnam

PhilippinesMalaysia

Indonesia

Australia

New Zealand

South Africa

Tanzania

Senegal

USA

Honduras

Ecuador

PeruBolivia

Chile

Argentina

Brazil

Greece

Sectos Load Breaking SwitchInstalled in more than 40 countries

Page 4: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 5

Sectos Load Breaking SwitchNXB and NXBD

NXB

Two-way load break switch

Three-position: ON / OFF /EARTH

NXBD

Three-way load break switch

Three-position: ON / OFF /EARTH

Page 5: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 6

Sectos Load Breaking Switch_NXBDStructure

NXBD

Three-way load break switch

2 position C/O

or 3-position: C/O/E© ABB GroupOctober 30, 2014 | Slide 6

Hook stick lever

Clear, reflectibleindicator

3 mm stainless steel tank

Silicone rubberinsulator

Operation housingIP67

Gas fillingvalve

Page 6: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 7

Sectos Load Breaking Switch_NXBDStructure

© ABB GroupOctober 30, 2014 | Slide 7

1 2

3

Page 7: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 8

Sectos Load Breaking Switch_NXBDFeature of NXBD

§ IEC 12-24 kV

§ 2- or 3-position load break switch

§ Silicone rubber insulator

§ Creepage distance 620mm

§ Low weight, appr. 141kg

§ Manual or motor operated

§ Protection degree of operate box IP67

§ Complete sealed 3mm stainless steel tank

§ Two separate Independent spiral springoperation mechanism with light reflecting andclear position indicator

Page 8: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 9

Sectos Load Breaking SwitchNXB and NXBD parameter

NXB NXBD

Rated voltage 12-24 kV 12-24 kV

Rated current 630 A 630 A

Number of breaking operation C – O ( undernormal load current) 400 400

Short time withstand current (4 sec) 20 kA 20 kA

Peak withstand current 50 kA 50 kA

Short circuit making operation(kA / operations)50kA / 5

31.5kA / 1050kA / 5

31.5kA / 10

Mechanical endurance C-O (No load operation)

Main switch 5000 5000

Earthing switch 2000 2000

Creepage distance 620/960 mm 620/960 mm

Two-way load break switch Yes -

Three-way load break switch - Yes

Page 9: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 10

Sectos Load Breaking SwitchNXBD

§ NXBD: double NXB

§ 3-way switch disconnector

§ Two independent operating mechanisms,one in each end numbered 1 and 2

§ Has all the features and functions of NXB

§ Especially useful for loop power supply

§ 1 input + 2 outputs or 2 inputs + 1 output

1 2

3

1 2

3

Two-position 3-wayswitch types NXBD__A_

Three-position 3-wayswitch types NXBD__C_

switchedway no.1

switchedway no.1

switchedway no.2

switchedway no.2

tapped way tapped way

Page 10: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 11

Sectos Load Breaking SwitchNXBD

§ NXBD application cases: Tölby station outside Vaasa,Finland

§ All 4 motors of the two NXBD are all controlled from thesame RTU (REC523 in the control box).

Before After

Page 11: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 12

Main Components of SectosContact system

§ Contact material: copperwith silver-plating.

§ Short time withstandcurrent: 20kA / 4 seconds.

§ Making current: 50kA / 5times

§ Effective arc extinction bycooling plate

§ Large clearance betweenopen contact gaps

§ Internal arc fault current16kA/1S

Page 12: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 13

Main Components of SectosEarthing Switch

§ Integrated earthing switchfor NXB & NXBD type

§ Earthing Switch for safetymaintenance

§ Close-open-earthingoperations sequence, onlyearthing the switch whenSectos is opened

§ Mechanical endurance2000 CO

§ Earthing switch can only beoperated by manualoperation for safety reason

Page 13: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 14

Main Components of SectosOperation Mechanism

§ Reliable manual and motor operation mechanism.

§ Independent spiral spring operation mechanism (no need

to charge the spring first)

§ Easy to be upgraded from manual operation to motoroperation at site

§ Operation mechanism box made from aluminum alloy

§ Spray painting of RAL7035, anti-corrosion, IP67

Page 14: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 15

Main Components of SectosPosition Indicator

§ Large position indicatorsymbols

§ Reflective colours

§ Visible even at night

§ The reliable indication ofthe device meets thedesign and testing of IEC129 A2

Page 15: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 16

Main Components of SectosGas Pressure Indicators

§ Temperature compensated gas density switch and gauge

§ Gas density switch: gas-low contact (NC) will open whenthe gas pressure is below 1.2bar, the alarm is then sent tothe relay

§ Gas gauge: under the tank, with large indication symbols.

Page 16: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 17

Main Components of SectosGas Pressure Locking Devices

§ Optional gas-low locking device and manual locking device.

§ Gas-low locking device will lock the switch when gaspressure is below 1.1bar, the alarm contact (NC) will openand providing the signal to the relay

§ The switch will be completely locked when manual lockingdevice is active, and the motor control circuit is alsoautomatically disabled in the locked position

Page 17: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 18

Main Components of SectosMeasurement Input Signals

Ring type current transformer for current measurement

§ Installed around the bushings for protection and monitoring

§ Easily to be installed and replaced.

§ Internal solution is also available

§ Service conditions: -40...+40 ℃.

§ Ith/Idyn: 20/50 kA.

§ Type: KOKU 072 G4

§ Ratio: 400/1A,600/1A

§ Burden/Class 3VA/5P10(0.5) 0.5VA/5P20

Page 18: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 19

Main Components of SectosMeasurement Input Signals

§ With 3 ABB voltage sensors (KEVCY 24 SA 2) and 3Combi sensors (KEVCY 24 SB 3)

§ Or 6 local capacitive voltage dividers and 3 currenttransformers

§ Providing 6 voltage inputs and 3 current inputs.

Page 19: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 21

Summary

§ Completely sealed stainless steel tank (Leakage<0.15% per year)

§ ABB patent spiral spring operation mechanism with clear indicator

§ Reliable, stable gas density switch and gauge with temperaturecompensation

§ Gas-low locking device or manual locking device as options

§ Easily upgrading from manual to motor operation

§ Safe, compact design and wide dynamic range of the sensorsolution

§ Powerful relay solution with strongly logic function

§ Full options for Sectionalizer: Current-count and Voltage-time

Page 20: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 22

Contact

Ganjar NugrahaPower Product Medium VoltageTlp. : 021-2551 5555 / 0811-9998004E-mail : [email protected] : www.abb.com

Page 21: Sectos SF Load Break Switch - ABB Group...Gas-low locking device or manual locking device as options Easily upgrading from manual to motor operation Safe, compact design and wide dynamic

© ABB GroupOctober 30, 2014 | Slide 23