Page 1: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

1

Securitas Operation Centre

Operational and Administrative Manual

Page 2: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

2

Contents

1. Introduction

1.1 Scope

1.2 Normative References

1.3 Registration & Approvals

1.4 Contact Details

2. Technical Arrangement

2.1 Monitoring Structure, Disaster Recovery and Business Continuity

2.2 Telecommunications (voice and data)

2.3 Monitoring Product Approval

3. SOC Administration

3.1 SOC Administration Department

3.2 Data Security (Passwords)

3.3 Standard Forms

3.4 New Connections

3.5 Transferring Systems to our SOC

3.6 Takeover of another Company’s Monitored Connection at our SOC

3.7 Alarm Configuration

3.8 Critical Data Omissions (CDO)

3.9 Data Changes

3.10 Monitoring Suspension & Reinstatement Suspension

3.11 Transferring Systems to an alternative SOC

3.12 Cancellation

3.13 Confirmation of Administrative Instructions

3.14 Reports

4. Commissioning Approved Monitoring Connections

4.1 Monitoring Products

4.2 Commissioning procedure

4.3 Commissioning Certification

5. Alarm Monitoring Responses

5.1 Alarm Response Performance

5.2 General Requirements – Alarm Signal Processing

5.3 Fire and Police (Agencies) Attendance

5.4 Filtering Policy

5.5 Mis-Operation Signals

5.6 Personal Attack/Hold-up Alarm Conditions

5.7 Intruder Alarms

5.8 Types of Confirmed Intruder Alarm

Page 3: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

3

5.9 Path Failure Alarm Conditions

5.10 Fault and Other Advisory Alarm Conditions

5.11 Linkdown Message

5.12 Late Restoral Alarm

5.13 Systems with Opening and Closing Time Schedules

5.14 Digital Communicator – Timer Tests

5.15 Unknown Signals

5.16 Excessive Signals

5.17 Calling Contacts/Keyholders

5.18 Calling Premises

5.19 Adverse Weather Conditions – Delays in Monitoring

5.20 Multiple Signalling Sites/Systems

5.21 Multiple Path Failures (Flood Conditions - WebWay)

5.22 Reasonable Alarm Monitoring and Associated Charges

5.23 Pre ACPO Responses

5.24 Remote Resets

6. Placing Systems On or Off Test

6.1 Testing Conditions

6.2 On Test Expiry Conditions

7. CCTV Pollution Management

8. Additional Services

8.1 Out of Hours Emergency Demand Service Calls

8.2 Loneworker Monitoring Services

9. Data Protection

10.1 GDPR

10.2 Audio Recording for SOC Telephone Conversations

10. Glossary Terms

11. Certification

Page 4: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

4

1. Introduction

1.1 Scope

This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd

and shall not be used or copied without our permission. Companies who connect monitored services

with us are permitted to use extracts from this document to form their own terms and conditions of

service to their customers.

This booklet sets out necessary information regarding the administrative and operational services

provided to Companies and End Users for the provision of monitoring services and should be read in

combination with our standard terms and conditions. Although we have attempted to cover all

aspects of service provision, the references cannot be extensive and our trained staff are always

available to assist you further.

Prior to connecting systems to our SOC you will need to have agreed a monitoring contract with us.

Alarm Responses stated throughout this booklet are in accordance with the ACPO / NPCC Policy,

ACPOS Policy and the industry standards noted under “Normative References” below. Reference to

pre-ACPO 2000 Alarm Response Plans.

Throughout this booklet “Company” refers to the organisation that provides service and

maintenance for alarm systems or who pays for the monitoring service for example Alarm Company,

National Account or End User, see Glossary for further definitions and abbreviations used

throughout this booklet.

Our commitment to the continual improvement of our quality systems and procedures to meet the

needs of our clients and to reflect changes in industry requirements means the contents of this

document are subject to change without notice.

1.2 Normative References This booklet has been formulated from Industry Standards and is intended as a guide to Companies who connect monitored services with our Alarm Receiving Centre (SOC). This guide is based on, and should be read in conjunction with, the following reference documents:

National Police Chiefs’ Council

ACPO (Association of Chief Police Officers) Security Systems Policy

Police Scotland - Security Systems Policy

BS5839 Fire detection and alarm systems for buildings

BS8473 Code of practice for management of false alarms

BS EN 50518 Code of practice for remote centres receiving signals for security systems

BS7858 Code of practice for security screening of individuals employed in a security environment

BS8484 Code of practice for the provision of lone worker device (LWD) services

Page 5: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

5

BS8243 Code of practice for the Installation and configuration of intruder and hold-up alarm systems designed to generate confirmed alarm conditions

BS EN 50131-1 Alarm systems - Intrusion systems - Part 1. General requirements

BS EN 50131-6 Alarm systems - Intrusion systems - Part 6. Power Supplies requirements

BS EN 50136 (All parts), Alarm Systems - Alarm transmission systems and equipment

PD6662 Scheme for the application of European standards for intruder alarm systems

Data Protection Act For alarm systems installed in Southern Ireland the following documents are also referenced:

• IS228 Monitoring Centres for Intruder Alarm System • SR25 SOC’s Alarm Handling Procedures • SR41 Electronic Security Services – Monitoring Services • Garda Siochana Policy on Monitored Intruder Alarms • PSA 33 Licensing Requirements Alarm Monitoring Centres

Installing and maintenance companies should also ensure that the technical requirements of control panel manufacturers and monitoring transmission providers are complied with. 1.3 Registration & Approvals Our Alarm Receiving Centre operates as trading divisions of Security Monitoring Centres Limited, registered in England No. 318215. The Alarm Receiving Centre (SOC) is assessed under the National Security Inspectorate (NSI) Gold Scheme as a Category II SOC for the monitoring of Fire and Intruder Alarms, monitoring of Lone Worker Devices and registered with the Private Security Authority in Ireland for the monitoring of Intruder Alarms and CCTV Alarm Systems. For further details refer to the certificates of approval within section 12. 1.4 Contact Details SOC Telephone number 01908-658100 Email [email protected] Opening times 24/7/365 Admin Telephone number 01908-658158 Email [email protected] Opening times 08:00 to 17:00 Monday to Friday Technical Helpdesk Telephone number 08081686486 Email [email protected] Opening times 24/7/365

Page 6: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

6

2. Technical Infrastructure 2.1 Monitoring Structure, Disaster Recovery and Business Continuity Through significant investment, our SOCs are supported via a redundant network to which enhanced alarm and voice call routing is managed. To best optimise service delivery, Companies are normally supported by a ‘host’ centre within our group. However, we may provide services from an alternate centre to maintain customer service levels.

2.2 Telecommunications (voice and data) The majority of the telephone lines into the SOC are covered by British Telecom’s total care maintenance package. On suspecting, or receiving a message form a client, that a line is faulty the Duty Supervisor shall check the line by either dialling into or out from the line. The telephone systems at Cobra House and the Fenny Stratford SOC are all interconnected in a way that provides a great deal of resilience. In the event one of the systems fails, the handsets shall automatically connect to an alternate phone system. In the event an issue prevents the phones connecting to an alternate system, a software based phone installed on each operator terminal can be configured to connect to any of three specified phone systems. Calls into the SOC are normally routed through the Fenny Stratford SOC and to the Cobra House SOC. In the event an interruption of service prevents calls being delivered in the normal way, the Supervisor can invoke a call forwarding plan to divert calls to SIP trunk lines presented at the SOC. Instructions how to achieve this shall be stored in the SOC Go-bag. A mobile phone shall be stored in the SOC GO-bag to help making calls in the event of a catastrophic failure. If the supervisor is satisfied that the line is out of order he should report it to British Telecom’s fault line and obtain a reference number and log the incident in the Non-conformance Log. The Supervisor may also seek advice from the Duty CTO technician(s). Should both lines of any receiver group the SOC Director and/or the CTO Director of Technology should immediately be advised. It should be noted that this is likely to be exceptional since signalling receivers are split between Cobra House and Fenny Stratford SOC and connected to independent telephone exchanges. Digital communicator numbers are presented on ISDN lines terminated on server based receivers. Support details for the receivers can be found in the SOC Go-bag. However, any suspected fault should be immediately escalated to the Duty CTO technician(s). All telephone calls are recorded as required by BS EN 50518. 2.3 Monitoring Product Approval In the event a supplier wishes to bring a new product to the monitoring market, we have a multiple staged approval process to ensure the product is compatible with our monitoring network and that we have configured response plans to interpret alarm signals received.

Page 7: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

7

Companies using equipment connected to our SOC’s that have not been approved do so at their own

risk. The full list of currently approved monitoring products is detailed in our monitoring application

forms.

3. SOC Administration

3.1 SOC Administration Department

Our SOC administration is provided by a dedicated centralised team. In emergencies, our

operational centres can support basic administrative functions but we ask that wherever

possible these are requested during normal office hours only (Mon–Fri 08.30 – 17.00).

3.2 Data Security (Passwords)

All SOC’s operate a security discipline that requires persons contacting the SOC by

telephone to have a valid password before security information can be exchanged.

An audit of engineer’s and customer authorised access provision should be completed by

the Company at least once per annum. If a customer or engineer is no longer an employee

of the Company or End User Site, the SOC should be notified immediately so their access

can be terminated from the SOC monitoring system.

3.3 Standard Forms

Due to the security nature of instructions and to provide consistency and minimise errors it

is preferred that all applications for monitoring, subsequent data changes and cancellations

are completed on the correct form and submitted electronically via email.

We aim to process all instructions received before 12 noon on a weekday during the same

working day and instructions received after 12 noon, at weekends or bank holidays, the next

working day, (our normal working day is 0800 - 1700 Mon to Fri excluding English Bank

Holidays).

3.4 New Connections

All new connections should be processed on our connection forms and be emailed to

[email protected]

3.5 Transferring Systems to our SOC

3.5.1 Single Transfer-in

Ensure that the SOC is in receipt of a completed connection form and the form indicates this

is a transfer from another SOC and includes the identification number and the name of the

Page 8: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

8

relinquishing SOC. The application must include details of keyholders, zone requirements

and URN’s as these are sometimes not provided by the losing SOC.

Once the service provider has received the losing SOC’s confirmation, the transfer can go

ahead. Our SOC will then inform you that the system is ready and an engineer may be

required to attend site and complete the transfer.

If attending site the engineer should contact the SOC.

The engineer should ensure:

• The system is put on test and they advise us they are transferring the monitoring

service from another SOC to us.

• Every channel is activated noting order of transmission, i.e. Intruder, Open, Close,

Restore, etc.

• The requirements of Section 4.0, Commissioning Approved Products, are followed.

• We have received the correct channels in the appropriate order and have all the

correct data, e.g. Contacts/Keyholders, etc.

The system will normally be made 'LIVE' following expiry of the initial test period unless we

are instructed otherwise by the engineer.

3.5.2 Volume Transfer-in

The Company is required to provide full details of each connection to be transferred in,

including:

• Site Names & Addresses

• Contact Details

• URN's and their status

• Zone Details & Response Plans

• Open/Close Details & Schedules where required

• STU Numbers

SOC Administration will add the details to the Monitoring System Database.

Once agreement is reached that all system details are correct a date of transfer can be

agreed between the Company, the monitoring service provider and both SOC’s.

SOC Administration on the day of transfer and following days as required will run event

history reports to ensure that the systems transferred are signalling correctly or

alternatively any specific commissioning requirements agreed with the Company are carried

out.

Page 9: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

9

3.6 Takeover of another Company’s Monitored Connection at our SOC

It is imperative that the following procedures are adhered to at all times.

1. Both companies involved with the takeover must write to the SOC stating their intention

to either release or to accept the end-user to their account. Note: without these documents

the SOC will not be able to transfer the site as it is contracted to the current Company.

Companies can use the standard application forms.

2. The documents should include the following information:

CS number

Name

Full address

Signalling type

Police Force

URN

URN Status (i.e. Withdrawn or Normal)

Contacts/Keyholders

Zones and alarm response

Proposed transfer date

3. All critical data should be reviewed with the end-user to ensure accuracy.

4. The Company should check the SOC responses are correct and will meet the end-user

expectation, attention should be given to pre and post ACPO 2000 responses.

5. Transfers should be carried out Monday to Friday 09-00hrs to 16-00hrs, excluding all bank

holidays.

6. Billing will continue up to the transfer date and the out-going Company will be

responsible for these charges. After the transfer the new company will be responsible for

any transfer costs and the on-going monitoring charges.

7. The URN belongs to the Maintenance Company and the gaining company must write to

the authority, (using Appendix “F” of the Police Force Policy), prior to the transfer informing

them of the transfer. This may include a fee dependant on the authority. Failure to notify

the authority prior to the transfer may render the URN null and void.

Page 10: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

10

8. When the transfer is complete the SOC will normally confirm the cancellation to the

outgoing company and a new connection to the new company.

9. It is strongly recommended the system is re-commissioned and fully tested to our SOC as

detailed in section 4.2.

10. In the event the out-going company will not release an end-user account to a new

provider the only option is for the new provider to apply for a new account in the normal

way.

11. The SOC will not accept any responsibility if these procedures are not adhered to in full.

3.7 Alarm Configuration

To establish a common approach across the SOC, the default communication channel

designations are detailed in the commissioning section.

Our connection form details the connection type which will normally default by system type

to these zones with the appropriate agreed business response. If you wish to deviate from

these standard responses this must be clearly indicated on your application or through a

pre-existing agreement of default responses.

Changing grade of monitoring products

In the event the monitoring service is re-graded it is essential that the following guidelines

are adhered to:

1. The customer should be notified and the alarm system specification updated.

2. It is recommended that the customer is advised to obtain agreement from their insurance

company of the grade change.

3. When transferring the data from the old product to the new product a full commissioning

test should be carried out, see section 4.2.

4. On completion of the grade change a cancellation of the unwanted product should be

completed, refer to Section 3.12.

The SOC does not accept any liability for changes in monitoring product, unless items one;

two and three above are completed in full.

Page 11: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

11

Pre-ACPO 2000

Should an existing system be transferred to us and a pre-ACPO 2000 alarm response is to be

retained, we must be clearly instructed of this requirement on the application form.

Channel Configuration for EN50131 Systems

Under EN50131 there are requirements to send additional signals such as AC Mains Fail and

Tamper faults to the SOC. The main additional requirements are dependent on System

Grade as follows:

• For Grade 3 and Grade 4 systems, it is necessary to send AC mains fail signals if the

standby battery capacity is to be halved from 24 hours to 12 hours

• For Grade 3 and Grade 4 systems, it is necessary to send tamper signals to the SOC in

the set and unset conditions

3.8 Critical Data Omissions (CDO)

In the event that any critical information is missing on completion of a connection, (e.g.

Contacts/Keyholders, telephone numbers, URN’s, etc.), the Company will be informed of

missing information, usually by e-mail, a report will be also sent monthly detailing any

missing information on the company estate.

Failure to run or act upon reports received and make corrective actions could result in

customers/end-users not receiving the correct alarm dispatch, information they have paid

for or incurring additional cost. Our SOC will not accept any liability for failed alarm dispatch

or telecommunications costs from a third party supplier or customers/end-users where

reports have not been addressed with appropriate corrective actions.

3.9 Data Changes

3.9.1 Securitas Processed Changes

All data changes should be completed preferably via MASWeb or e-mailed to

[email protected]. We aim to process all data change requests received before

1200 hours on a normal working day the same day. All written data changes received after

1200 hours or outside the normal working day will be processed during the next normal

working day. The normal working day is defined as: 0830 - 1700, Monday to Friday excluding

'English' bank holidays.

3.9.3 Contacts/Keyholders:

Page 12: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

12

All change requests should list ‘all Contacts/Keyholders’, this will enable us to check that we

have them listed in the correct sequence and update our records accordingly. For changes

made via MASWeb it is important that all Contacts/Keyholders on the database have a

sequence number and contact telephone number, Contacts/Keyholders with no sequence

or telephone numbers will not be presented to a SOC operator for alarm dispatch.

It is important when advising the SOC of new or changes to existing Police and Fire Authority

URN’s that the elements the URN applies to is specified, i.e.

• PA only

• INTRUDER only

• PA & INTRUDER

• Fire only

Any changes to URN’s requested on a weekend are normally processed the next working

day.

3.10 Monitoring Suspension & Reinstatement Suspension

A method used by the SOC to ignore all alarm conditions for a period of more than 24 hours.

All instructions must be confirmed in writing or via email to [email protected]:

• Billing will continue during the suspension period.

• The SOC will not allow suspensions with an end date.

• The Company must review the suspended systems weekly to ensure the suspension

is still required.

Re-instatement

The instruction to reinstate a suspended system is normally required in writing, but may be

accepted over the telephone from an Authorised Contact/Keyholder, Company

Representative or Engineer.

3.11 Transferring Systems to an alternative SOC

3.11.1 Single Transfer-Out

The SOC’s agreement to participate in the transfer of monitored systems to another SOC,

unconnected with us, is dependent on the existing contractual arrangements in place

between the Company and our SOC. Terms and conditions can apply to both the Company’s

overall account and to individual monitored systems i.e.

• The account is within an initial fixed term.

• The monitored system is within its first year.

• The agreement to transfer or the agreement to a date of transfer will also be

dependent on the payment of any outstanding or future invoices.

Page 13: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

13

Our SOC Administration should be contacted in the first instance to progress any transfer

enquiry.

3.11.2 Volume Transfer-Out

1. A written instruction is required from the Company authorising our SOC to exchange

information with the alternative SOC.

2. The Company or alternative SOC, on the Company's behalf, shall provide our SOC with a

list of systems requiring transfer. Once agreement is reached that all system details are

correct a date of transfer can be agreed between the Service Provider and both SOC’s.

3. Our SOC will normally cancel the monitoring connections, subject to transfers, within 48

working hours of the agreed date of transfer without further instruction. All rights and

liabilities placed on our SOC shall cease at the time of transfer.

3.12 Cancellation

To ensure the accurate and timely cancellation of monitoring services, requests to cancel

will only be accepted by the completion of the appropriate Form, Company Email or

Letterhead to the Administration Department by one of the following options.

• Email: [email protected] (preferred option)

• Post: Securitas Security Services, Cobra House, FAO SOC Administration, Wavendon

Business Park, Milton Keynes, MK17 8LX

IMPORTANT:

1. Approved and processed cancellations will normally be confirmed back to the Company in

writing (email where available), within 24 hours of receipt. Any cancellations submitted that

are not confirmed within stated timescales must be queried as failure may lead to a delay in

cancellation.

2. We will not respond to alarm signals received following cancellation and it is important

that the communicator at the protected premises is removed or disabled to prevent further

signals being transmitted and associated telephone charges being incurred.

3. Any cancellations requested on a weekend will be processed the next working day.

3.13 Confirmation of Administrative Instructions

Automatic confirmation is provided by email, or post if not available, for all requests placed

for new services and cancellation of existing services; changes to existing services may also

be notified by email if required. Should the Company not receive the expected confirmation

they should contact the SOC administration team at their earliest opportunity.

Page 14: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

14

It is the Company’s responsibility to ensure that instructions sent have been received, this

may be achieved by receipt of an automated notice of confirmation for new orders and

cancellations.

3.14 Reports

Business Critical Daily / Weekly Reports

Our SOC provides the following reports. It is strongly recommended that all these reports

should be run daily / weekly and corrective actions completed on a daily / weekly basis.

1. Daily Activation Reports History – Lists all alarm incidents in the specified date range

2. Weekly Sites not commissioned – Lists sites ordered but not connected out of service

category “Needs Commissioning”

3. Weekly Systems in Path Failure – List all sites in signal path failure

4. Daily High Activity Sites – Lists of sites sending excessive signals

5. Daily New Connected Sites Reports – Lists the newly connected sites for the date range

specified

6. Daily Systems in Alarm Condition – Lists Unrestored alarm conditions

7. Monthly False Alarm Management – List all alarm conditions that require a reason code

Company Business Critical Monthly Reports

The MASWeb access allows companies to assign disposition codes against alarms and as an

aid to compliance with BS 8473 Intruder and hold-up alarm systems – Management of false

alarms – Code of practice.

Our SOC encourages the management of false alarms and strongly recommends the use of

the specific software written by the SOC to highlight reasons why alarm systems create false

alarms and corrective actions to reduce false alarm signal traffic to the SOC.

Automated Reports

The following automated reports are available to the Company on request:

1. Daily Activation Reports History – Lists all alarm incidents in the specified date range

Page 15: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

15

2. Systems in Path Failure – List all sites in signal path failure

3. High Activity Sites – Lists of sites sending excessive alarm signals

4. Health Check Report – this includes:

• Systems Awaiting Connection

• New Systems within the last 12 months

• Suspended Systems

• Systems Cancelled within the last 12 months

• Systems with No Site Password or Common Key-Holder Password

• Systems with less than 2 Key-Holders

• Systems Missing Data such as Premises Phone or Postcode

• Systems without an Agency or URN

• Systems with Reduced Police Response

• Systems with No Scheduled or Log-Only Open/Close within the last 30 days

• Systems with Unrestored Zones

• Systems with greater than 5 activations within the last 12 months

• Systems Out of Service

• Fire System with No Fire Brigade Response

5. Service Call Report (out of hours engineer call handling)

Where there is a requirement to send reports by post these will be sent by second-class

post.

4. Commissioning Approved Monitoring Connections

4.1 Monitoring Products

Our SOC’s support all major suppliers and their associated products in the security industry.

Any new products go through our product approval process, referred to in section 2.3,

before being connected to our SOC network.

Every new connection and system upgrade should always be commissioned to our SOC

network as detailed below.

4.2 Commissioning procedure

The following procedure must be adopted for all new, transferred and system upgrades.

1. Submit an approved application form to SOC Administration at least 24hrs in advance.

2. Ensure the Commissioning procedure can be completed during normal working hours and

before 16:00 hours.

Page 16: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

16

3. Contact our Administration Help Desk on 01908658158

4. Confirm what services are being connected and request the system to be placed ‘in-

service’ & ‘on-test’.

5. Test each alarm & restore condition, including single and dual path failures.

6. Check all the SOC responses meet with the end-users expectations.

7. Panel manufacturers and signalling providers may delay certain types of alarm conditions

to the SOC so be aware of these delays and how they can be tested.

8. Contact our Administration Help Desk on 01908658158 for test results.

9. Confirm all alarm signals sent have been received in the correct order.

10. The Help Desk will validate the ‘Signalling Test’ and ensure that all the information

required to support the Alarm Response has been provided.

11. On completion, the site will be taken off test and a commissioning report submitted to

the Company. It is important that the Company advises the SOC if a Commissioning Report is

not received.

4.3 Commissioning Certification

To help the Company identify the standard to which the alarm system is commissioned to

the SOC, two critical elements for effective monitoring are assessed during the

commissioning process:

1. Signalling – All zones and path failures including dual path failures have been tested and

the engineer has called back after the test to validate the results.

2. Data - All Critical Data is present on the monitoring system (MAS), for example

Name

Address & Post Code

Premises Tel Number

Keyholders (minimum of two) with appropriate contact numbers

Password for authentication of false alarms & other enquiries

5. Alarm Monitoring Responses

Page 17: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

17

5.1 Alarm Response Performance

Our SOC’s undertake to meet the standards for contacting the emergency services as set out

in BS EN 50518 & BS 8591 for Category II SOC’s, which are:

1. Fire 30 seconds for 90% of signals received, 90 seconds for 98.5% and 180 seconds for

100%

2. PA 30 seconds for 80% & 60 seconds for 98.5% signals received

3. Intruder 90 seconds for 80% of signals received and 180 seconds for 98.5% of signals

received.

These targets are exclusive of any imposed filtering period and exceptional circumstances

such as extreme weather conditions and the associated abort signals received under these

conditions.

5.2 General Requirements – Alarm Signal Processing

Our standard response to alarm signals is detailed within this section. All actions taken by

the SOC are as indicated unless the Company advises otherwise. It is the responsibility of the

Company to advise the End User what action the SOC will normally follow on receipt of an

alarm signal.

All alarms are assigned a priority as indicated in the table below. In the event of multiple

alarm signals only the highest priority alarm will be processed.

Our SOCs will only act on alarm signals received at the SOC. We accept no liability for signals

lost for whatever reason by suppliers or their agents.

Signal Type Priority

Loneworker 9

Fire 10

PA 20

Confirmed Intruder 39

Intruder 40

Line Fault 45

Trouble 46

Environmental 50

Page 18: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

18

5.3 Fire and Police (Agencies) Attendance

Agencies may have individual policies which you must comply with to ensure we can

dispatch alarms to them on your behalf. The SOC has dedicated telephone numbers with

most agencies where appropriate.

Agencies will respond in accordance with their published policies and where they require a

URN, it is the responsibility of the Company to ensure the SOC is in possession of a valid

URN and its response status is ‘active’.

Our SOC will not be liable for delays in response from agencies.

It should be noted that within any contractual agreement or communication we cannot

make any commitment that would involve assuming the powers of a civil authority, i.e. UK

Police, Garda Siochana or Fire Service, etc.

In some cases agencies may request the Company or the SOC to deviate from normal policy.

In these circumstances requests should be made in writing from the agency and directed to

the Customer Service Manager or the National Administration Manager. On receipt we will

propose a solution and communicate with the company. Such variations should be kept to

an absolute minimum. The SOC does not accept any liability for procedures that deviate

from standard policy.

Current policies can be accessed from the following web sites. Note these may have regional

variances.

ACPO policy (England and Wales) - http://www.acpo.police.uk/

England, Wales and Northern Ireland Police Response to Security Systems

Police Scotland - http://www.scotland.police.uk/

Scotland Security Systems Police Policy

CFOA policy - http://www.cfoa.org.uk

Fire Authorities Policy

5.4 Filtering Policy

The following filtering techniques are in accordance with ACPO Policy, Police Scotland

Policy, BS8243 and BS EN 50518.

For alarm systems installed in Southern Ireland the filtering requirements of ‘Monitoring

Centres for Intruder Alarm Systems’ (IS228) and the Garda Siochana Policy on Monitored

Intruder Alarms apply.

Page 19: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

19

5.5 Mis-Operation Signals

All systems shall either:

1. Send an unset/set (open/close) signal (Preferred Option)

or

2. Be capable of generating a secondary signal to indicate that the alarm system has been

mis-operated.

Where we are unable to identify whether the system is set/unset (open/closed) we will

action as "closed".

All intruder alarm conditions are delayed in accordance with the relevant agency policy

waiting for a mis-operation signal to abort the alarm. These are:

1. Open

2. Abort

At any time prior to operator intervention if the SOC receives items 1 or 2 the alarm

condition will be automatically aborted due to mis-operation.

Open/Close with monitored line communications

Where the SOC is asked to monitor communication path failures, i.e. PSTN/GPRS/GSM/IP

Networks & others it is imperative that the transmission equipment is programmed to send

open/close signalling to the SOC without exception. The reason for open/close is to allow

the SOC to make decisions based on the status of the alarm system to conform to ACPO and

EN50131. Failure to enable open/close signalling may render an incorrect response to alarm

conditions received at the SOC.

Should a Fire Authority response be required to fire alarm signals this must be specified on

the monitoring application form.

Fire Authority responses may be subject to individual Fire Authority filtering policies as per

the Chief Fire Officers Authority (CFOA) http://www.cfoa.org.uk .

It may be necessary to contact the premises prior to contact with the Fire Authority. If you

have dispensation for the SOC not to call the premises, we will normally need a copy of the

letter of authority from the Fire Brigade for the SOC to remove this facility.

Some Fire Authorities require Unique Reference Numbers (URN’s) for the SOC to be able to

dispatch calls to them. Some Fire Authorities adopting the CFOA call challenge procedures

Page 20: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

20

may refuse to attend a Fire Alarm unless the customer/premises confirms they have a fire &

furthermore these Brigades do not accept a ‘no reply’ as a confirmed situation.

In cases where open and close is monitored via the security system, we will normally not call

the premises in response to a fire alarm when they are known to be closed.

If our response to fire alarm signals requires changing we would normally expect to receive

this instruction in writing.

5.6 Personal Attack/Hold-up Alarm Conditions

It is our SOC policy that all PA’s/Hold Up Alarm conditions are police-able immediately (no

filter) with a valid police URN on level one police response. Normal Police rules apply see

section 5.3.

Confirmed hold-up alarms

BS 8243: 2010 sets out the requirements for confirmation of hold-up alarms where this is

required under ACPO or Police Scotland policies:

ACPO: 2014 states,

“3.4.5 For restoration of HUAs which have lost response, confirmation is mandatory”

Thereby Hold-up Alarm Systems (HAS) will be required to incorporate alarm confirmation

technology to gain reinstatement of Police response should the PA URN become withdrawn.

Types of confirmation

BS8243: 2010 clause 4.2.2 states:

“HASs should incorporate one or a combination of the following alarm confirmation

technologies:

1 audio confirmation

2 visual confirmation

3 sequential confirmation

4 telephone confirmation (call back)

An explanation of the selected combinations should be provided to the user/client to ensure

the most appropriate confirmation technology is used.

Unless agreed with the client in writing, sequential confirmation should be used only in

conjunction with telephone confirmation.

The installer should obtain written confirmation of the client/user’s acceptance of the

chosen option, and detail how the confirmation works”.

1) Audio Confirmation

Page 21: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

21

It must be clearly stated on the monitoring application form that audio confirmation is

required of Hold-up Alarms and the type of confirmation used. We only accept audio

systems with ring back.

Before commissioning the system please ensure the SOC is in receipt of a completed

application form and the form states the type of audio verification system used and the

telephone number which is to be used to dial up the system for alarm verification purposes.

2) Visual Confirmation

Where visual confirmation is required of Hold-up Alarms for systems designed to comply

with BS5979 and BS8243 rather than BS8418.

A typical response to a video confirmed hold-up alarms system is stated below.

2.1 Event is received and upon dialling into the video system there is no sign of activity

on site the SOC will contact the contacts/keyholders as an unconfirmed alarm.

2.2 Event is received and upon dialling into the video system there is sign of activity on

site the SOC will contact the police and contacts/keyholders.

3) Sequential & Telephone Confirmation

For hold-up alarm conditions to be considered sequentially confirmed BS8243: 2010, clause

5.4.1.2 states:

a) the HAS should be configured so that at least two separate alarm conditions are reported

within the confirmation time; and

b) signals emanating from HDs (hold-up devices) should be from either;

1) two or more HDs separately identifiable at the CIE; or

2) a multi action HD.

The hold-up confirmation time should be not less than 8 hours and not more than 20

hours”.

It must be stated on the monitoring application form that sequential confirmation is

required of Hold-up Alarms and the transmission protocol used.

Before commissioning the system please ensure the SOC is in receipt of a completed

application form and the form states the type of sequential verification used and the alarm

response required.

Default SOC Response

A) Hold–up alarms system without confirmation will result in only the police being

called.

Page 22: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

22

B) Hold-up alarm system with sequential confirmation will result in only the contacts

being called for the first alarm and only the police if the confirmation has been

received.

The hold-up confirmation time configured by the alarm system control and indicating

equipment (CIE) at the protected premises must not be less than 8 hours and not more than

20 hours. If at the expiry of the confirmation time HDs remain in an alarm condition and are

inhibited a signal should be sent from the CIE to the SOC.

Notes: 1. To function correctly and to minimise the likelihood of false alarms occurring a

signal must be sent to monitoring centre when channels are restored to their quiescent

state.

2. For systems sending SIA Protocol: If receipt of the ‘HA’ mnemonic should be interpreted

as

‘Duress’ and passed to the Police, you must advise us of this on application otherwise it will

be interpreted as an unconfirmed hold-up alarm.

To distinguish between a confirmed intruder alarm and a confirmed hold-up alarm for

systems signalling both events via the same alarm channel, i.e. usually channel 7 for ‘fast

format’, an extra event is attached to the system called ‘CONFPA’, this recognises, through

interrogation of the previous alarm events, when the alarm should be processed as a

confirmed hold-up event rather than a confirmed intruder event.

System Designation

As of 1st June 2012, new systems that specify confirmation of hold-up alarms will attract an

alarm response to the requirements of BS8243: 2010 and PD6662: 2010 unless we are

instructed otherwise.

If confirmation of hold-up alarms is not specified, our default response plan, will be applied

and unconfirmed hold-up alarms will be passed to the police.

It is important to ensure that we are informed of new systems that should receive an alarm

response to an earlier standard than BS8243: 2010 and PD6662: 2010 and of existing

systems that are upgraded to current standards and should have their response plan

changed.

5.7 Intruder Alarms

Type of Alarm Actions taken by the SOC

Unconfirmed Intruder Alarm Premises and Contacts/keyholders

Confirmed alarm when closed Police and Contacts/keyholder

Confirmed alarm when open Premises or Contacts/keyholders

Unconfirmed alarm followed by an open/abort No Action Taken

Page 23: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

23

Confirmed alarm followed by an open/abort signal

No Action Taken

All police calling systems must have a unique reference number (URN) for the SOC to be

able to dispatch to them.

All new intruder alarm systems installed within an ACPO or Police Scotland Authority Area

that require a police response and systems that have had police response withdrawn but

now require police response reinstating must incorporate confirmation technology.

All intruder alarm signals received from sequential confirmed intruder alarm systems within

premises residing in ACPO or Police Scotland Authority Areas are held for 120 seconds in

order that they may be aborted or confirmed by a second detector.

Southern Ireland Only: All intruder alarm signals received from sequential confirmed

intruder alarm systems within the Garda Siochana Police Authority Areas are held for 60

seconds in order that they may be aborted or confirmed by a second detector.

5.8 Types of Confirmed Intruder Alarm

5.8.1 Sequentially Confirmed Alarms

Sequential alarms are perhaps one of the simplest confirmation technologies. The SOC just

needs to know that two independent detectors or two detectors of different technologies

have activated within the protected premises.

Signals are held for an intentional delay of 120 seconds for premises residing within ACPO or

Police Scotland Authority Area's in order that they may be aborted or confirmed by a second

detector.

Should a confirmed intruder alarm signal be received within the alarm filter period of the

initial alarm, on expiry of the initial filter time the alarm is presented to an operator for

action as a confirmed alarm.

Should the End User send a mis-operation signal or a signal to indicate the system is unset

prior to any action by the SOC the alarm will normally be automatically aborted.

It is important that alarm systems incorporating sequential confirmation are set to re-arm

within a time window (30 - 60 minutes) following initial activation to prevent the

transmission of a confirmed alarm signal and to prevent the SOC from carrying out the

incorrect action on any subsequent activation. Should the zone that generated the initial

Page 24: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

24

unconfirmed alarm be isolated on re-arm then a signal should be sent to the SOC to indicate

a zone has been omitted.

Southern Ireland Only

Signals are held for a minimum of 60 seconds for premises residing within the Garda

Siochana Police Authority Area's in order that they may be aborted or confirmed by a

second detector.

Type of Sequentially Confirmed Alarm

A confirmed signal must be delivered by the appropriate mnemonic code within the

protocol used, the SOC will not accept ‘any’ second event as a confirmed alarm condition

and for second zone reporting the channels for the unconfirmed and confirmed intruder

signal must be pre-designated on application to the SOC.

Open & Close signals with Point ID and SIA

It is strongly recommended that open/close signals are enabled to the SOC when using Point

ID and SIA. In the event the Company wishes to disable open/close thorough checks must be

made by the Company to ensure all associated signals are also disabled when

commissioning the site.

It is the Company’s responsibility to ensure that every element of the connection is tested

with the SOC and the response required is confirmed.

It is imperative when changing control panel suppliers that a full test is carried out with the

SOC to ensure the connectivity and response required is correct.

The SOC cannot accept any responsibility for Point ID and SIA systems where the open/close

signals are disabled and associated zones are left enabled with no additional zones being

created.

5.8.2 Audibly Confirmed Alarms

Audio confirmation requires the SOC to listen to audio data from the protected premises

following the receipt of unconfirmed intruder alarm signals. We only accept audio systems

with ring back.

Page 25: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

25

Before attending site please ensure that SOC is in receipt of a completed Connection Form

and the form states the type of audio verification system used and the telephone number

which is to be used to dial up the system for alarm verification purposes.

The SOC should be contacted prior to the system being connected to place the system in-

service and on-test.

Testing of all microphones should be carried out in local mode by the engineer on site in

accordance with the manufacturers’ recommendations.

When you are satisfied with the audio coverage, the SOC should be contacted to carry out a

test dial into the site to ensure the system is working correctly and sounds can be heard.

For compliance with BS8243, audio systems must incorporate technology capable of

detecting and signalling to the SOC a sequential confirmation alarm should two detectors

activate that meet the sequential confirmed requirements of this code of practice.

Should a sound be heard then we will treat as a confirmed alarm. The SOC will not use

discretion.

The maximum time our SOC agent should listen is one minute. The Company must ensure

audio systems are configured to provide this response to ensure the alarm receives the

correct action by the SOC. All audio systems must send open/close signals to the SOC

5.8.3 Visually Confirmed Systems

We provide CCTV monitoring through our CCTV monitoring platform Immix.

For systems designed to comply with BS5979 and BS8243 rather than BS8418: Video

systems must incorporate technology capable of detecting and signalling to the SOC a

sequential confirmation alarm should two detectors activate that meet the sequential

confirmed requirements of BS8243.

5.9 Path Failure Alarm Conditions

EN50131 and EN50136 calls for signalling suppliers to report line failures to the SOC in the

following timings

Grade Primary Secondary

Grade 2 25 Hours 25 Hours

Grade 3 5 Hours 25 Hours

Grade 4 180 Seconds 5 Hours

Page 26: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

26

Signalling supplier’s interpretation of this standard may be different depending on grade

and supplier. Please check with your nominated supplier for the reporting times by grade.

The SOC will only respond to path failures received by the monitoring software (MAS) as

documented below unless otherwise instructed by the company or end-user or the site has

become troublesome as detailed in section 5.15. Changes to response must be documented

in writing.

Alarm Type Status Response

Single Path Failure Open Notification Via Email

Dual Path Failure Open Premises or Contacts

Single Path Failure Closed Notification Via Email

Dual Path Failure Closed Premises or Contacts

3. Systems that monitor path failures must also transmit open/close signals and restores

without exception to the SOC. This is to ensure the correct response to path failures is

carried out. Care should be taken to ensure the open/close signals are working the correct

way round. Our SOC will accept no liability for incorrect actions where the open/close

signals are working back to front.

4. The SOC may abort a response if the line failure restores in a reasonable time frame.

5. On receipt of restore signals the status of the corresponding path failure condition will be

returned to its dormant state, the SOC will log this event.

6. STU's that have temporarily lost power due to power supply problems may go into ‘no-

response’. The use of the “UP STU” command also allows for the possibility of STU

substitution in an attempt to compromise the system. Our SOC recommends that the “UP

STU” command is only used on instruction from an alarm engineer who has previously

placed the systems “on test” from the customer’s premises. Our SOC will only "UP" a STU in

response to an alarm event with a valid password or with prior written authorisation from

the Company and we do not accept liability for any loss or error that may occur as a result of

this action.

7. Single path failure conditions of EN50131 Grade 2 & 3 systems are normally filtered for 60

minutes and Grade 4 systems for 2 minutes in order that the alarm may be aborted through

receipt of a restore signal to avoid unnecessary call to Keyholders.

All intruder alarm signals received from sequential confirmed intruder alarm systems within

premises residing in ACPO or Police Scotland Authority Areas are held for 120 seconds in

order that they may be aborted or confirmed by a second detector.

Page 27: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

27

Southern Ireland Only

Where the alarm signalling and monitoring arrangements are such that a communication or

transmission fault might possibly give rise to Garda Siochana call-out, the Company should

advise the subscriber in writing at the time the alarm-monitoring agreement is being set up

that communication or transmission faults that result in Garda Siochana call-out can

adversely affect future Garda Siochana response to the alarm system.

Path Failure Reporting

Our SOC will normally advise the Company the next working day by report should a Path

Failure remain in 'Fault' for greater than 24 hours. Systems set to ‘log only’ may not report.

Our SOC considers that any 'duty of care' responsibilities to the Company in respect to

systems exhibiting signal failure will have been fulfilled following the above actions.

5.10 Fault and Other Advisory Alarm Conditions

Following the increased signalling requirements of EN50131 the number of signals to be

sent to the SOC have noticeably increased, especially those categorised as low priority or

advisory.

Customers recognise these low level alarms as ‘advisory events’ and in many cases,

dependent upon their circumstances, only require that these are recorded in a report for

subsequent review.

The default response to a range of fault and advisory events will be for our IVR system to

automatically call the premises and/or contacts/keyholders. If the signal restores in an

acceptable amount of time then the alarm will be aborted.

All these events are available by report for the Company to view the next working day as

necessary. It is the Company’s responsibility to action these events to the end-user where

applicable and to ensure corrective actions are carried out as required where required.

Where the event is a trouble, polling, communications path or other unexpected event, it is

recommended that a full test of the alarm system including every zone and all signalling

paths is carried out to the SOC for each alarm and restore channel.

All events are available as LOG only where requested by the customer.

Page 28: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

28

5.11 Linkdown Message

“Linkdown” is a message sent to the SOC if the BT Scanner in the exchange has lost

connectivity with the subscriber transmission device (STU) normally through planned

outages on the BT RedCARE network. Our operational teams suspend these “Link Down”

messages normally from 60 to 120 minutes depending on the severity of the volume of

alarms as the majority do restore (Link OK) in this time. This could in some circumstances

effect the transmission of the GSM also.

As a duty of care if we do not see the “Link OK” in a reasonable time frame we will notify the

customer of the situation.

5.12 Late Restoral Alarm

BS8243 requires all intruder signalling systems to send restores without exception. All

connections should be commissioned with the zones working the correct way round. It is

bad practice to ask the SOC to invert the response and act on restores.

The majority of intruder and path failure conditions that have failed to restore in

approximately 90 minutes from full clearing the alarm condition may be reported by the

LRAC processing. The Late Restoral Alarm processing is a reportable service on MASWeb.

When the Company identifies a Late Restoral Alarm, they should proceed to restore the

alarm condition as soon as possible.

Where the Late Restoral Alarm is a signal path failure this may take longer to rectify by the

path supplier but still needs the company’s attention. Until the alarm zone is restored, the

SOC may not be in a position to action any further alarm conditions from that zone or zones,

this includes signal path failure alarms.

5.13 Systems with Opening and Closing Time Schedules

Our SOC offers timed monitoring for open and close signals against a time schedule

normally at an additional cost.

LTC – Late to Close (Additional charges may apply)

ETO – Early to Open (Additional charges may apply)

Late to Close and early to open notifications

Response to the above notifications would normally be from our operators, when calling the

premises they will request a password and a new close time, this new close time will be

added to our system.

Page 29: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

29

This process should be repeated if the protected premises has not closed by the new close

time. If the premises do not answer or confirm the correct password the call will be referred

to premises keyholders. If there is no response from any keyholder we will try for a

maximum of 4 hours after this the alarm will be cleared from our system.

5.14 Digital Communicator – Timer Tests

Systems communicating via Digital Communicators that are required to send a signal to the

SOC every 24 hours which meets the requirements of EN50131, should be configured to

send daily timer test signals. The SOC monitoring system will normally log these signals and

should a Digital Communicator fail to signal, the Company will receive an automated email

at the time of the missed signal.

5.15 Unknown Signals

If the SOC receives signals from a site/customer but the signal is unknown to the SOC we will

normally disregard the signal. This unknown signal will be reported to the customer the next

day on their daily report.

5.16 Excessive Signals

The SOC monitors excessive signal traffic. Should a particular site/system become

'troublesome', through the receipt at the SOC of unknown signals, unwanted signals or

repetitive alarm incidents, we will normally inform the company of the site affected. Our

SOC reserves the right to charge for excessive signal traffic.

5.17 Calling Contacts/Keyholders

There should be a minimum of two Contacts/Keyholders available 24 hours a day for seven

days per week, unless a 24-hour key holding service is utilised in accordance with ACPO

requirements. It is recommended, even if a 24-hour key holding company is employed, that

key holders are still maintained in the unlikely event the key holding company are unable to

attend.

When calling the contacts/keyholders we will ring for approximately 60 seconds before

terminating the call, if the contact/keyholders are unavailable at the time of the alarm we

will sleep the alarm for a minimum of 15 minutes and will make further attempts to contact

them up to but not exceeding 2 hours.

When the SOC initiates the telephone call to the Contact/Keyholder we normally ask for the

named contact but we don’t require a password at this point. Once a legitimate

Contact/Keyholder has been contacted the incident will be closed. Should a

Contact/Keyholder decline to attend the premises it will be their responsibility to contact

Page 30: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

30

another authorised Contact/Keyholder. The SOC cannot advise on what actions the

Contact/Keyholder should make. It is recommended if the SOC calls a Contact/Keyholder

they attend the protected premises without exception.

Interactive Voice Response (IVR)

We currently use an IVR to deal with low priority alarm events, the IVR system will call the

contact/keyholders and notify them of the full address of the site and the alarms that has

been received. The recipient of the IVR call will need to press 8 on their telephone keypad to

accept the call. In the event that the recipient does not answer or does not press 8 the

system will call the next contact/keyholder on the list. In the event all contacts/keyholders

have been called and none of them accept the alarm, the system will sleep the alarm and try

again after 5 minutes.

5.18 Calling Premises

There are two premises telephone number fields available on the monitoring database and

only premises telephone numbers should be contained in these fields. Under no

circumstances should the premises number be inserted in the keyholder fields as this may

cause confusion for operators and may render the password not being requested which is a

security risk.

5.19 Adverse Weather Conditions – Delays in Monitoring

Our SOC maintains operating levels to meet normal fluctuations of alarm signal traffic and

have contingency plans in place should alarm signals reach unacceptable levels. In

exceptional circumstances, notably through severe weather conditions where signals

received exceed the number of operators available, the alarm queue will normally be

managed in order of priority by type of event and time of receipt. In such conditions, if an

Abort or Open signal is received from a queuing alarm condition this may be aborted and

not presented to an Operator.

If the delay continues, only the highest priority alarms may be dispatched. The SOC may

introduce automated keyholder contact during this period.

5.20 Multiple Signalling Sites/Systems

It is strongly recommended that for every signalling system only one site is associated.

Connecting multiple signalling sites/systems can be very complex in nature and should be

discouraged.

For example, a digital communicator signalling with two intruder sites shop 1 and shop 2

should have separate zones/pins per shop.

The commission process would need to ensure that both areas are fully tested.

Page 31: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

31

We accept no liability if sites are not fully commissioned to the SOC.

5.21 Multiple Path Failures (Flood Conditions - WebWay)

All networks are susceptible to disruption and occasionally this may affect a large number of

remote locations monitored by the SOC. The potential impact on the operation is serious as

multiple communications failures are reported to our agents simultaneously.

Flood condition identifies a mass network outage and protects the SOC from a flood of

communication failures being delivered to operators. The end-user should benefit from

unnecessary disturbance due to planned/unplanned network maintenance that does not

compromise the integrity of their remote IAHS systems (where dual path systems have been

deployed).

Activation of Flood automatically delivers a high level alarm to SOC support. The status of

the sites affected are then monitored, and once the network outage has cleared Flood

Condition is released.

Flood does not block the delivery of alarm activations from the protected premises to the

operator (e.g. Fire, Intruder, Open, Close, Confirmed Intruder, etc.).

5.22 Reasonable Alarm Monitoring and Associated Charges

Our SOC reserve the right to charge for additional alarm/activity where excessive traffic is

not fair and reasonable and deemed to be over and above normal expected levels, before

any charges are received we will attempt to contact the customer and notify them via email.

Once the email has been sent the SOC expects the customer to rectify the issue in a

reasonable amount of time.

5.23 Pre ACPO Responses

The following is our SOC standard alarm response plan for systems issued with a URN prior

to ACPO 2000 or ACPOS 2002 (as amended 1st April 2005), which have not had their police

response withdrawn.

Service Type Response

PA Police

Intruder (Site Closed) Police & Contacts/Keyholders

Confirmed Intruder Police & Contacts/Keyholders

5.24 Remote Resets On receipt of a telephone request for a remote reset by an end user the operator must

Page 32: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

32

ensure that the guidelines are followed as per British Standards document BS 8473:2006+A1:2008, Section 10.1 to 10.9. Callers who demand or believe they have a right to Remote Reset will still be fully checked before a remote reset is authorized. If the caller is unable to quote the correct code word then no remote reset will be authorized, the caller will be asked to contact the site Maintenance Company. When a request for a remote reset is received the caller’s identity will be confirmed by use of: The Account Number The Account or Keyholder code word The Account Name and Address The Engineer’s ID Number The caller will then be asked the reason for the activation which must have been received at the SOC. The following are valid reasons for activation/reset when authorized by the Customer or at the request of the alarm engineer:

1. A Keyholder error 2. An incorrect entry procedure; 3. An incorrect exit procedure;

4. Insecure premises; 5. A twenty-four hour circuit has been activated (i.e. a fire door has been opened); 6. An animal or insect has caused the Alarm to activate. 7. The reset has been authorized by the Customer; 8. The reset is at the request of an Alarm Engineer.

A check will then be made on the account history file of our Alarm handling computer. If there are any previous activations on the account for which a valid known reason has been given, but if police action has been taken twice within the last rolling twelve months, the reset may be refused and the caller asked to contact the site maintenance company. If the caller is unable to give a valid known reason the caller will be asked to contact the site maintenance company and the remote reset will be refused. If the Caller can give a valid reason and has not had two polices alarm within a 12 month rolling period then the remote reset will be given by: 1. Log into the remote reset program and find the account. 2. Ask the customer what reset code they have 3. Put this code into the code box and click get reset 4. Give the code which is generated to the customer to enter in his alarm panel 5. If the reset was successful then click on successful reset 6. If the reset was not successful the click on failed remote reset and inform the customer that they need to contact they maintained company to get them to reset the system

Page 33: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

33

6. Placing a System On or Off Test

6.1 Testing Conditions

It is imperative if a system is being tested by a customer/engineer that it is placed ‘on test’

prior to testing. This will ensure that whilst testing, an alarm conditions are not passed to an

SOC operator for action and the creation of a call to the emergency services in error. To

place systems on test we have a few options:

1. The use of MASWeb

2. The use of MAS Mobile

3. Call the SOC

All monitored alarm systems must have a unique identifier number known as the chip

number and an authorised password.

6.5 On Test Expiry Conditions

All test periods expire automatically at the time set upon the commencement of a test

period or earlier if the Engineer/Customer contacts the SOC to complete the test.

If the SOC monitors restore conditions and a test automatically expires, but the system has

not been restored and remains in alarm, such conditions will be reported to the customer

the following day via their daily reports. The SOC will not accept any liability for tests that

expire with unrestored alarm conditions.

7. CCTV Pollution Management

There is a significant differential between healthy, well and regularly maintained sites and those that

have not been subject to review of procedures, false alarm activations and servicing schedules on a

regular or routine basis. There can be a serious impact from a site that is not healthy, well and regularly

maintained and where pollution and false alarm activity is not periodically reviewed with corrective

action being taken.

Securitas apply a prioritisation for handling CCTV alarms in a manner that is fairer to customers. The

rationale for this is a small number of highly polluting sites may generate a significant number of false

alarms, the volume of these alarms impacts on customers whose sites generate a low or expected

volume of alarms.

For the purpose of remote CCTV monitoring false alarms are defined as an CCTV alarm that is

activated, set off or signals to the monitoring station needlessly; causes an alarm or indicates an event

that proves to be unfounded; or gives a warning about untoward activity that fails to be present or

happen.

Page 34: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

34

On a 3 monthly basis a review will be undertaken to calculate the average number of CCTV alarms

generated by a site on a per month average basis. After this the below grading criteria will be applied.

A site where the highest score below has been applied, represents the highest priority in how a CCTV

alarm from a site will present to a SOC Operator for handling. The lowest grading will present to the

Operator as the last alarm to process. The rationale being that an average or standard site for example,

sending an average of 150 CCTV alarms per month will receive a faster response than a site that is

sending 10,000 alarms per month.

The grading table below sets out the grading of sites based on (the 3-month average) number of CCTV

alarms received:

CCTV Alarm Reporting

Our SOC produce a range of reports of site CCTV activity which are disseminated by email direct to

customers. These are available on a daily, weekly, monthly and/or ad-hoc basis. The purpose of the

reports is to highlight the activity, functionality and health of a system. I.e. no alarms over a number

of days indicates an issue at site which requires urgent investigation, likewise a very high number of

alarms (considered to be in excess of 300 per month) indicates a system that requires review and

investigation by the owner and/or their engineer to reduce the number of false alarms generated.

Customers are strongly recommended to have a robust process to review alarms on a regular basis

and it is recommended that this is combined with CCTV system walk testing and service schedules.

For any support or reporting requirements please contact [email protected]

Appeal Process

Should a customer take remedial action to resolve the number of false CCTV alarms being signalled

through from a site and wish their grading to be reviewed prior to the end of the 3-month review

period, to ensure that it is more accurately graded, this can be done by emailing the ARC

Administration team requesting in the title of the email ‘CCTV Grading Review Appeal’.

The ARC Administration team email address is: [email protected]

Priority Grading

Highest to Lowest

Monthly CCTV Alarms

(3 month average)

500 0-250

400 251-1,000

300 1,001-10,000

200 10,001-25,000

100 25,000+

Page 35: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

35

8. Additional Services

8.1 Out of Hours Emergency Demand Service Calls

Our SOC is able to offer an additional service to the Company for the handling of out of

hour’s service requests from their clients outside of normal working hours.

• Procedure – On receipt of a call from your customer, we will take their name,

address, contact name and number, reference numbers and what their issue is. These

details will be entered onto our system, whereby a message will be raise. We shall contact

the on call engineer via telephone. If we are unable to contact the engineer we will continue

to call them every 15 minutes. After 3 attempts we will proceed to call the companies

escalation contacts.

This service is available from 17:00hrs until 08:30hrs weekdays, all weekends and covering

all recognised Bank Holidays as standard.

8.2 Lone Worker Monitoring Services

Our Alarm Receiving Centre is inspected and approved for the monitoring of lone worker

devices to BS 8484 the code of practice for the provision of lone worker device services by

the National Security Inspectorate.

Lone workers are vulnerable from all aspects of risk and the provision of a lone worker

device may assist in summoning an emergency responder to assist when incidents occur

that requires assistance from a third party.

To enable the SOC to monitor and respond to signals received from a Lone Worker Device

effectively the following conditions apply:

1. The Lone Worker Device must comply with the requirements of BS8484 and the supplier

must issue a certificate of conformity for the device confirming compliance with and

detailing how compliance is achieved.

2. The type and model of lone worker device must have been accepted by the SOC as

compatible with its alarm monitoring platform and permit alarm signals to be managed to

the requirements of BS8484.

3. The SOC must be in receipt of a Monitoring Application Form for each device providing

personal details of the user as defined within BS8484.

4. The SOC may only pass lone worker alarms to the emergency services where listening-in

by the SOC operator or whilst in conversion with the user it is deemed by the SOC operator

that an emergency response is desirable. In all cases an emergency responder other than

the emergency services must be provided to assist the user in cases where an emergency

service response is unavailable.

Page 36: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

36

The requirements for Police attendance to lone worker devices is set out within Appendix V

of the ACPO Policy.

Incident data, alarm response plans, personal details of lone workers and customer details,

as provided to enable effective monitoring and response to activations received from lone

worker devices, are held within our BS EN 50518 approved SOCs.

9. Data Protection

9.1 General Data Protection Regulation

We will only process the personal information in accordance with your written instructions.

All our staff who process personal information provided by you are under a contractual

obligation of confidentiality. Securitas will provide reasonable support to assist you in

complying you’re your obligations under the GDPR. In the event of a data breach, we will

notify you immediately and provide the necessary support to enable you to comply with the

requirements of the GDPR and resolve the incident.

Personal information relating to you, your employees, your customers, their authorised

contacts and Keyholders will be held by our SOC on the Alarm Monitoring System. Please

ensure that relevant names, addresses and contact details are correct. Information received

by post or email, including replies and forwarded copies (which may contain alterations)

subsequently transmitted from the SOC are confidential and solely for the use of the

intended recipient within the purpose of the original transmission. The SOC will retain this

data including personal information either electronically or in hardcopy. Telephone calls to

and from our SOC’s are recorded for security purposes and you must ensure your

employees, clients and their authorised Contacts/Keyholders are aware of this. You must

ensure that you have a lawful reason to process the personal information you provide to us.

Personal data is retained for the periods defined within our Quality System. This is in

accordance with our recognition of operating BS EN 50518, as recognised by NSI, for the

monitoring of Intruder Alarms and Fire Alarms. Company employees who have access to

personal data, alarm system information and activation records are security screened to

BS7858 as part of the company induction process and continued employment is dependent

on successful security screening.

Page 37: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

37

9.2 Audio Recording for SOC Telephone Conversations

Our SOCs have to comply with BS EN50518, therefore all inbound and outbound telephone

conversations are recorded and held for a period in excess of one year. These recordings are

the property of our SOCs. We will only release copies of these recordings under the terms of

the Data Protection Act.

Release of recording to Data Subjects

By law, we must gain permission from all parties involved in the telephone conversation

before we can release copies. It is imperative even if we release copies these are not copied

or played back to a third party without our permission. To identify and reduce time taken to

recover telephone conversations it is necessary for the exact time and date of the telephone

call to be provided, without this information we will be unable to fulfil the request. The

copies will only be released by e-mail, and we reserve the right to charge for the service. We

do not normally make transcripts of audio conversations.

Page 38: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

38

10. Glossary Term Definition Alarm Condition Condition of an alarm system, or part thereof,

that results from the response of the system to the presence of a hazard.

Alarm Filtering Procedure whereby signalled alarm conditions are intentionally delayed at the SOC and their status reviewed for the purpose of preventing unnecessary calls to the relevant emergency service by cancelling certain alarm conditions in line with industry standards. It is the obligation of the Company to ensure the Customer is aware that some alarm signals may be filtered.

Alarm Message Message conveyed from an SOC to the relevant emergency service indicating that an alarm condition has occurred at a protected premises, or providing supplementary information concerning a previously reported alarm message.

Alarm Receiving Centre (SOC) Continuously manned remote centre to which information concerning the status of one or more alarm systems is reported. We trade in the UK under the trading name Securitas UK Ltd.

Alarm Signal Signal which, upon being received at an SOC or other remote location, identifies a signalled alarm condition.

Alarm Transmission Equipment (ATE) Defines equipment that transmits signals to the SOC.

Agency or/and Agencies An emergency service for example Police, Fire, Ambulance, Key holding Service, etc.

Audibly Confirmed Status in which an incident has been confirmed by an SOC Operator at a remote location (normally an SOC), having interpreted audio information transmitted from the protected premises, has made a decision that there is a high probability that a genuine intrusion, or a genuine attempted intrusion, has occurred.

Confirmed Alarm Condition that follows after two independent actions or signals have been generated from an audible, visual, or sequential source confirming there is a high probability that a genuine alarm has occurred.

Control and Indicating Equipment (CIE) Equipment for receiving, processing, controlling, indicating and initiating the onward transmission of information.

Commissioned System A statement used by the SOC to facilitate the connection process to ensure all the critical data is present and the signalling system has been tested to the SOC and commissioned by the attending engineer.

Company or Companies Organisation that provides service and maintenance for alarm systems or who pays for

Page 39: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

39

the monitoring service for example Alarm Company, National Account or End User.

Contact / Keyholder A representative of the protected premises with authority to make changes to the SOC response to signalled alarm conditions and/or attend the protected premises in response to signalled alarm conditions.

Control Panel Unit (CPU) The user interface for the alarm system. Customer / End-user Person or organisation utilising the services of an

Alarm Company. Disposition Reason Reason for alarm activity Early to Open (ETO) A system that is unset prior to the scheduled

opening time Global System for Mobile Communications (GSM)

A network used by some signalling devices to transport alarm conditions to the SOC.

General Packet Radio Service (GPRS) A network used by some signalling devices to transport alarm conditions to the SOC.

False Alert (FA) Signalled alarm condition that without having been extended to the relevant emergency service is regarded by the SOC as cancelled either by an open or abort, if programmed, or mis-operation validated by the customer / end-user quoting their authorised password.

History A table of event history, including open/close signal, alarm conditions, SOC actions and service call out logs (where applicable).

Hold-up Alarm System (HAS) An alarm system that incorporates Hold-up/Panic Alarm Devices

Intruder Alarm System (IAS) An alarm system that is designed to detect intrusion.

In Service A site/system placed ‘in service’ has reached a status where alarm conditions received will be processed by the SOC.

Internet Protocol (IP) A network used by some signalling devices to transport alarm conditions to the SOC.

Local Area Network (LAN) Local Network available to support communication suppliers to transport alarm conditions to the SOC.

Last Alarm Condition The last time an alarm condition was communicated to the SOC from the protected premises.

Late Restoral Alarm Condition (LRAC) An alarm condition that has not restored to its quiescent state within a predefined period.

Late to Close (LTC) A system that remains unset after the scheduled closing time.

Line Failure/ No Response / Line Fault / Path Failure

A break in the communications link between the protected premises and the SOC.

MasterMind The Alarm Receiving Centre monitoring software. Mis-operation signal Signal that is definitely and unambiguously

identifiable at the SOC as indicating to the SOC that the alarm system has mis-operated and

Page 40: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

40

therefore that the alarm signal is to be filtered out and not extended to the relevant emergency service.

Monitoring Centre Transceiver (MCT) Alarm transmission equipment. On test/off test A mechanism for an authorised person/engineer

to ask the SOC to ignore alarm conditions during a period of time not exceeding 24hours.

Operator / Agent A member of the SOC team who may be involved in dispatch of alarm conditions or administrative procedures.

Order The result of sending a monitoring application form to the SOC.

Out of hours (OOH) Out of normal working hours Out of service (OOS) Alarm signals received for a site/system that has

been placed out of service will be ignored until such time that instructions are received to reinstate the monitoring service.

Personal Attack/Hold Up Alarm A manually operated device at the protected premises, normally requiring a double input to be activated

Paknet - Vodaphone A network used by some signalling devices to transport alarm conditions to the SOC.

Polling A process used to determine if the signalling system is still in place and operational.

Polling Server (PSV) The server that is polling the communication device.

PIN (Personal Identification number)/ Password A unique identifier for the customer / end-user / engineer to identify themselves to the SOC.

Protected Premises The part of a building to which protection is afforded by an alarm system.

Public Switch Telephone Network (PSTN) A network used by some signalling devices to transport alarm conditions to the SOC.

Receiving Centre Transceiver (RCT) Alarm transmission equipment. Remote Restore / Remote Reset (RR) A process where the customer/end-user calls a

Restore Management Centre, normally the SOC, to obtain a code to facilitate resetting of the alarm system.

Response Agreement Set of instructions agreed between the SOC and the Company or End User as to the actions to be taken in the event of an alarm signal being received by the SOC.

Restore An alarm condition that has restored to its normal state.

Router Multilayer switching device Sequentially Confirmed Status in which confirmation emanates from two

or more independent sensors, detectors, hold-up devices and/or processors, which are so configured that there is a high probability that a genuine intrusion, or a genuine attempted intrusion, has occurred.

Page 41: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

41

Signalled Alarm Condition State of monitoring equipment at an SOC (or other remote location) that indicates intrusion, attempted intrusion or unauthorised interference has occurred at the protected premises, or is likely to occur.

Signalling The transmission of an alarm condition from the protected premises to a remote location.

Signalling Devices Transmission equipment for sending alarm conditions to the SOC.

Site/Protected Premises The location where the alarm is installed. Status This identifies the status of a zone and if it

requires restoring. Supervised Premises Transceiver (SPT) Alarm transmission equipment Suspend Monitoring A method to ask the SOC to ignore alarm

conditions for more than 24hrs, billing continues during this period.

System The alarm system installed at the protected premises.

Unconfirmed Alarm A single alarm activation, i.e. a signal that has not been designated as audibly, visually or sequentially confirmed

Unset / Set or Open / Close or Disarm / Armed Varying terms used to describe if an Intruder Alarm System (IAS) is set or unset.

URN & URN Status The Unique Reference Number (URN) issued by the Police or Fire Authorities and the

(Permit & Permit Dispatch Status) status, for example Level 1 (On Response) authorities may attend or Level 3 withdrawn (Off response) authorities may not attend.

User Person authorised to operate an alarm system. Visually Confirmed Status which is confirmed by an SOC Operator

being at a remote location (normally an SOC), after having interpreted a visual image transmitted from the protected premises, has made a decision that there is a high probability that a genuine intrusion, or a genuine attempted intrusion, has occurred.

Wide Area Network (WAN) External Network for communication suppliers to transport alarm conditions to the SOC.

Zones (Channels) Segmentation of the alarm system to enable differing alarm conditions to be identified and signalled to the SOC.

Page 42: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

42

11. Certification

Page 43: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

43

Page 44: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

44

Page 45: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

45

Page 46: Securitas Operation Centre · 4 1. Introduction 1.1 Scope This booklet and the material recorded herein is the property of Securitas Security Services UK Ltd and shall not be used

46