0.Abstract
2
I would like to explain … (1) Seismic motion Investigation for silent site selection. (2) Vibration isolation How to suppress seicmic noise ?
![Page 3: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/3.jpg)
Contents
1. Introduction 2. Seismic motion 3. Vibration isolation 4. Summary
3
![Page 4: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/4.jpg)
4
1. Introduction
Vibration of ground shakes mirrors.
Seismic noise limits sensitivity below 10 Hz. Sensitivity wall in low frequency region
![Page 5: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/5.jpg)
5
1. Seismic noise How can we reduce seismic noise ?
(1) Small seismic motion site
(2) Excellent vibration isolation system
![Page 6: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/6.jpg)
6
2. Seismic noise What is seismic motion ? If ground is perfectly equivalent to inertial frame, it implies no seismic noise (mirrors must be on inertial frame). Seismic motion is acceleration. Accelerometer is necessary for measurement. We often show power spectrum density of displacement, not acceleration. Acceleration spectrum is divided by (2πf)2 to convert acceleration to displacement.
![Page 7: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/7.jpg)
7
2. Seismic noise Site selection is essential !
How do we measure seismic motion ?
It is not easy even if seismic motion is typical one …
(a) Excellent (not usual !) commercial accelerometer
(b) Sensor made by ourselves …
One example : Michelson interferometer
A. Araya et al., Review of Scientific Instrument 64 (1993) 1337.
![Page 8: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/8.jpg)
2. Seismic noise Typical seismic motion
10-7[m/rtHz](1Hz/f) 2
(above 1Hz)
K. Arai, master thesis (1997)
![Page 9: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/9.jpg)
2. Seismic noise Typical seismic motion
Micro seismic peak (around 0.2 Hz) due to sea waves near coast. Amplitude strongly depends on weather.
K. Arai, master thesis (1997)
![Page 10: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/10.jpg)
2. Seismic noise
Measurement around center of Kamioka mine (CLIO)
T.Sekiguchi, JGW-T1402971
![Page 11: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/11.jpg)
2. Seismic noise
11
Under ground site has two orders of magnitudes smaller seismic motion.
R. X. Adhikari Reviews of Modern Physics, 86(2014)121.
![Page 12: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/12.jpg)
1. Seismic noise (1) Small seismic motion site
12
Under ground site has two orders of magnitudes smaller seismic motion.
R. X. Adhikari Reviews of Modern Physics, 86(2014)121.
![Page 13: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/13.jpg)
13
2. Seismic noise Where is Kamioka mine ?
![Page 14: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/14.jpg)
14
Location of LCGT LCGT is planed to be built underground at Kamioka, where the prototype CLIO detector is placed.
By K. Kuroda (2009 May Fujihara seminar)
![Page 15: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/15.jpg)
15
2. Seismic noise Many people measured seismic motion in Kamioka mine.
100 times smaller seismic motion at center of Kamioka mine.
However …
K. Yamamoto, JGW-G0500217, G0500218
![Page 16: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/16.jpg)
16
2. Seismic noise
All measurement was at center of mine. Mirror must be far from center !
K. Yamamoto, JGW-G0500217, G0500218
![Page 17: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/17.jpg)
17
2. Seismic noise
Measurement outside of mine and shaft
K. Yamamoto, JGW-G0500217, G0500218
![Page 18: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/18.jpg)
18
2. Seismic noise
Measurement at Atotsu office K. Yamamoto, JGW-G0500217, G0500218
![Page 19: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/19.jpg)
19
2. Seismic noise
Outside of Mozumi office
Exit of Mozumi shaft
Mozumi office
K. Yamamoto, JGW-G0500217, G0500218
![Page 20: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/20.jpg)
20
2. Seismic noise
Measurement apparatus
K. Yamamoto, JGW-G0500217, G0500218
![Page 21: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/21.jpg)
21
2. Seismic noise
Truck K. Yamamoto, JGW-G0500217, G0500218
![Page 22: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/22.jpg)
22
2. Seismic noise
Electric locomotive
K. Yamamoto, JGW-G0500217, G0500218
![Page 23: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/23.jpg)
23
2. Seismic noise Fixed accelerometer in Mozumi shaft
10 cm
K. Yamamoto, JGW-G0500217, G0500218
![Page 24: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/24.jpg)
24
2. Seismic noise
Outside of mine <1 Hz (Outside of mine) =(Center of mine) >1 Hz (Outside of mine) >(Center of mine) Vertical motion is similar to horizontal one. Results of other locations are similar.
K. Yamamoto, JGW-G0500217, G0500218
![Page 25: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/25.jpg)
25
2. Seismic noise
Inside of mine > 50 m Silent sufficiently ! Main mirrors 50 m from ground
K. Yamamoto, JGW-G0500217, G0500218
![Page 26: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/26.jpg)
26
2. Seismic noise
Mirror displacement around 10Hz must be below 10-19 m/rtHz. Seismic motion around 10Hz is 10-11 m/rtHz even at Kamoka. At least 8 (in typical, 10) orders of magnitude vibration isolation is necessary !
![Page 27: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/27.jpg)
27
2. Seismic noise
R. X. Adhikari Reviews of Modern Physics, 86(2014)121.
Mirror displacement around 10Hz must be below 10-19 m/rtHz. Seismic motion around 10Hz is 10-11 m/rtHz even at Kamoka ! At least 8 (in typical, 10) orders of magnitude vibration isolation is necessary ! No silver bullet ! We need many tricks !
![Page 28: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/28.jpg)
28
3. Vibration isolation
Mirrors must be suspended because they should act as like free mass. Otherwise, transfer function from gravitational wave to detector output is too small. “Suspended” mirror is also isolated from seismic motion.
![Page 29: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/29.jpg)
29
3. Vibration isolation
Mirrors are suspended.
Slow motion Mirror follows motion of support point.
Rapid motion Mirror can not follow motion of support point.
![Page 30: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/30.jpg)
30
3. Vibration isolation Transfer function : (Motion of mirror)/(Motion of support)
Motion of mirror
Motion of support f0
![Page 31: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/31.jpg)
31
3. Vibration isolation
Typical resonant frequency 25cm pendulum, 1Hz
Transfer function : (Motion of mirror)/(Motion of support)
f0
![Page 32: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/32.jpg)
32
1. Seismic noise
Not enough …
Transfer function : (Motion of mirror)/(Motion of support)
f0
![Page 33: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/33.jpg)
33
3. Vibration isolation How to improve isolation ratio ? Softer spring (Lower resonant frequency)
f0 10 times smaller
100 times smaller
M. Ando, JGW-G1503397
![Page 34: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/34.jpg)
34
3. Vibration isolation How to improve isolation ratio ? Softer spring (Lower resonant frequency)
f0 10 times smaller
100 times smaller
Pendulum f0 ~ l-1/2 (l is length.) 1Hz : 25cm 0.1Hz : 25m !
![Page 35: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/35.jpg)
35
3. Vibration isolation How to improve isolation ratio ?
Soft pendulum with reasonable size
Inverted pendulum Elasticity : Positive spring constant Gravity : Negative spring constant Both spring constants cancel each other. 30mHz resonance is feasible.
A. Takamori, LCGT design document (2004)
![Page 36: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/36.jpg)
36
3. Vibration isolation How to improve isolation ratio ?
Soft pendulum with reasonable size
Inverted pendulum Elasticity : Positive spring constant Gravity : Negative spring constant Both spring constants cancel each other. 30mHz resonance is feasible.
A. Takamori, LCGT design document (2004)
![Page 37: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/37.jpg)
37
3. Vibration isolation How to improve isolation ratio ?
Soft pendulum with reasonable size
Inverted pendulum Elasticity : Positive spring constant Gravity : Negative spring constant Both spring constants cancel each other. 30mHz resonance is feasible.
A. Takamori, LCGT design document (2004)
![Page 38: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/38.jpg)
38
3. Vibration isolation How to improve isolation ratio ?
Soft pendulum with reasonable size
Inverted pendulum Elasticity : Positive spring constant Gravity : Negative spring constant Both spring constants cancel each other. 30mHz resonance is feasible.
A. Takamori, LCGT design document (2004)
![Page 39: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/39.jpg)
39
3. Vibration isolation How to improve isolation ratio ?
Soft pendulum with reasonable size
A. Takamori, LCGT design document (2004)
Inverted pendulum Drawbacks (1)Soft spring can be broken easily (tilt..). Control system or limiter are necessary. (2)Elasticity depends on temperature. Small temperature change causes drastic change of resonant frequency.
![Page 40: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/40.jpg)
40
3. Vibration isolation How to improve isolation ratio ?
Multiple pendulum
M. Punturo, GWDAW Rome 2010 Mirror
VIRGO: Super Attenuator
![Page 41: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/41.jpg)
41
3. Vibration isolation How to improve isolation ratio ?
Double pendulum as example of multiple pendulum
Mirror Mirror
K. Arai, master thesis(1997)
Upper mass
![Page 42: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/42.jpg)
42
3. Vibration isolation How to improve isolation ratio ?
Double pendulum as example of multiple pendulum
(f0/f)2
(f0/f)4
N-stages (f0/f)2N
20dB=10 40dB=100
K. Arai, master thesis(1997)
![Page 43: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/43.jpg)
43
3. Vibration isolation How to improve isolation ratio ? Double pendulum as example of multiple pendulum
One peak
Two peaks N-stages N peaks
K. Arai, master thesis(1997)
![Page 44: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/44.jpg)
44
3. Vibration isolation We are interested with gravitational wave above 10Hz. Do we need NOT to take care of vibration below 10 Hz ?
R. X. Adhikari Reviews of Modern Physics, 86(2014)121.
![Page 45: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/45.jpg)
45
3. Vibration isolation We are interested with gravitational wave above 10Hz. Do we need NOT to take care of vibration below 10 Hz ? Contribution from this low frequency region dominates root mean square of vibration. Root mean square (RMS) is integral of power spectrum in all frequency region. In typical case, RMS is on the order of µm. Even at Kamioka, it is several times 10 nm. Dynamic range for interferometer (detector) is about 1 nm.
![Page 46: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/46.jpg)
46
3. Vibration isolation Dynamic range of interferometer (detector) is about 1 nm. Control and damping is necessary. Since they could be noise sources, we have to design carefully (weaker effect of control or damping is better). For example … Double pendulum with eddy current damping
Upper mass
Mirror
Magnets
K. Arai, master thesis(1997)
![Page 47: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/47.jpg)
47
3. Vibration isolation Eddy current damping
Magnets (metal) move near metal (magnets). Eddy current occurs. This electric current in resisitance is dissipation .
Wikipedia Eddy current
![Page 48: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/48.jpg)
48
3. Vibration isolation
Resonant peaks are suppressed.
K. Arai, master thesis(1997)
![Page 49: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/49.jpg)
49
3. Vibration isolation
Magnet is fixed on ground. So, this damping introduce seismic motion.
K. Arai, master thesis(1997)
![Page 50: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/50.jpg)
50
3. Vibration isolation
Magnet is also suspended. So, seismic motion can not be introduced.
K. Arai, master thesis(1997)
![Page 51: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/51.jpg)
51
3. Vibration isolation
Control (or damping) have to work only around resonant frequency (about 1 Hz). Otherwise, noise by this system contaminates observation band (above 10 Hz).
![Page 52: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/52.jpg)
52
3. Vibration isolation Only upper mass is applied eddy current damping. It can suppress resonant motion because both masses move. On the other hand, noise by damping can not be transferred to mirror because stage between upper mass and mirror act as vibration isolation.
K. Arai, master thesis(1997)
![Page 53: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/53.jpg)
53
3. Vibration isolation Passive vs Active Eddy current damping -> Passive (without any power supply) Active (with power supply) : For example, monitors and actuators. Active system is more complicate. On the other hand, we can use some tricks. However, points for design are same; Control (or damping) works only around resonant frequency (about 1 Hz). On the contrary, we have to stop it in observation band
![Page 54: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/54.jpg)
54
3. Vibration isolation Vertical vibration isolation Is it problem ? Yes, due to curvature of Earth !
θ~ 0.2mrad
![Page 55: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/55.jpg)
55
1. Seismic noise Vertical vibration isolation Imperfection of suspension (differences between wires …) make coupling between vertical and horizontal motion. In other words, vertical seismic motion causes not only vertical motion of mirror, but also horizontal one. Roughly speaking, the ratio is 1/100 or 1/1000. In the case of KAGRA, baseline has 1/300 gradient to drain water.
![Page 56: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/56.jpg)
56
3. Vibration isolation Vertical vibration isolation Spring constant k (resonant frequency) of vertical motion is higher than that of horizontal motion in usual. Typical resonant frequency Horizontal 1 Hz, Vertical 10 Hz Summary (1)Vertical-horizontal coupling (2)Higher vertical resonant frequency ->Vertical motion effect is larger.
![Page 57: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/57.jpg)
57
3. Vibration isolation Vertical vibration isolation
A. Takamori, LCGT design document (2004)
![Page 58: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/58.jpg)
58
3. Vibration isolation Vertical vibration isolation Softer vertical spring has larger stretch from natural length. Vertical resonant frequency is proportional to k1/2. Stretch from natural length is proportional to k. Resonant frequency Stretch from natural length 10 Hz 2.5 mm 1 Hz 25 cm 0.1Hz 25 m
![Page 59: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/59.jpg)
59
3. Vibration isolation Vertical vibration isolation Soft vertical spring with reasonable size KAGRA adopts Geometrical Anti Spring (GAS).
![Page 60: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/60.jpg)
60
3. Vibration isolation
60
Geometrical Anti Spring (GAS) Elasticity : Positive spring constant Compression : Negative spring constant Both spring constants cancel each other. 0.2 Hz resonance is feasible.
A. Takamori, LCGT design document (2004)
Vertical vibration isolation Soft vertical spring with reasonable size
![Page 61: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/61.jpg)
61
3. Vibration isolation
61
Geometrical Anti Spring (GAS) Elasticity : Positive spring constant Compression : Negative spring constant Both spring constants cancel each other. 0.2 Hz resonance is feasible.
A. Takamori, LCGT design document (2004)
Vertical vibration isolation Soft vertical spring with reasonable size
![Page 62: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/62.jpg)
62
3. Vibration isolation
62
Geometrical Anti Spring (GAS) Elasticity : Positive spring constant Compression : Negative spring constant Both spring constants cancel each other. 0.2 Hz resonance is feasible. Same drawbacks of inverted pendulum …
A. Takamori, LCGT design document (2004)
Vertical vibration isolation Soft vertical spring with reasonable size
![Page 63: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/63.jpg)
63
4. Summary Summary of seismic motion
Underground site is excellent. 100 times smaller seismic motion
Depth of mirror must be more than 50 m. If not so, seismic motion is not so small even if the site is country side …
Typical seismic motion : 10-7[m/rtHz](1Hz/f)2 (above 1Hz) Microseismic peak is around 0.2 Hz.
![Page 64: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/64.jpg)
64
Summary of vibration isolation
Soft vibration isolation with reasonable size Cancel of positive and negative spring constant
Not only horizontal but also vertical motion must be supressed.
4. Summary
Multiple pendulum to enhance vibration isolation ratio
Control and damping to suppress resonant motion is necessary. But they have to work only around resonant frequency (about 1 Hz). Otherwise, noise by this system contaminates observation band (above 10 Hz).
At least 8 (in typical, 10) orders of magnitude vibration isolation is necessary.
![Page 65: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/65.jpg)
65
Thank you for your attention !
![Page 66: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/66.jpg)
66
1. Seismic noise (1) Small seismic motion site
Where is silent sites ? Underground !
BFO (Black Forest Observatory): -162m BRG (Berggieshübel seism Observatory): -36m GRFO (Graefenberg borehole station): -116m Kamioka (Kamioka mine): -1000m
Kamioka mine
M. Punturo,
GWDAW Rome 2010
![Page 67: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/67.jpg)
67
1. Seismic noise (2) Good vibration isolation system
Unfortunately, single pendulum does not have enough isolation for gravitational wave detection.
We need multi stage isolation system.
M. Punturo, GWDAW Rome 2010
VIRGO: Super Attenuator
Mirror
![Page 68: Seismic noise and vibration isolation - University of …...1 Kazuhiro Yamamoto Department of Physics, Faculty of Science, University of Toyama Seismic noise and vibration isolation](https://reader034.vdocuments.net/reader034/viewer/2022042100/5e7cd12c766d5f3dc05bfbc1/html5/thumbnails/68.jpg)
68
3. Vibration isolation Vertical vibration isolation Stack : rubber and spring.