Setting(I recommend we develop a mission statement)
• The October 15, 2006 earthquake caused substantial damage to several parts of both Keck 1 and 2. See: \TSD Planning\TSD Development Projects\Seismic Upgrade\2006 Quake Recovery Doc
• New requirements-driven restraints shall protect both telescopes See: \TSD Planning\TSD Development Projects\Seismic Upgrade\Requirements document
![Page 3: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/3.jpg)
Project Milestones (as of 2/25/11)
• System req review (completed 2/25/11)• PDR 3/29/11• DDR 5/3/11• K1 installation and testing complete 7/19/11• K2 installation and testing complete 8/23/11• Documentation complete 8/30/11• ORR 9/5/11
![Page 4: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/4.jpg)
USGS data 10/15/2006 collected on summit of Mauna Kea
Overview:
• Ground movement graphs (slide 4)
• Acceleration data: N-S, E-W, and vertical (slide 5)
• Fast Fourier Transform of E-W accelerations
![Page 5: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/5.jpg)
![Page 6: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/6.jpg)
For USGS accelerometer data see: \TSD Planning\TSD Development Projects\Seismic Upgrade\Seismometer data from 2006 seismic event
![Page 7: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/7.jpg)
FFT of E-W accelerations. First 20 seconds during the maximum intensity.
note: over time the peak frequency varies about +/- 1 Hz with a broad range to excite many resonances in telescope
![Page 8: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/8.jpg)
Existing azimuth restraints
• Keck 1 and Keck 2 have different seismic restraints systems!
• Keck 2 restraints built into radial hydrostatic support. (slide 10, 11)
• Keck 1 has additional large (white) radial restraints. (Slide 9)
• ½” MHMV pads provides crushable interface between the radial hydrostatic pad supports and the az journal (K1&K2)
• Uplift restraint is supplied by radial pads (K1 &K2) (see slide 11, 12)
![Page 9: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/9.jpg)
K1 Seismic Restraintnote: white nylon(?) pad between restraint and journal bearing
![Page 10: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/10.jpg)
Keck 1 restraint system
![Page 11: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/11.jpg)
Hydrostatic radial support
![Page 12: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/12.jpg)
Damage from 2006 earthquake.
![Page 13: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/13.jpg)
FEA model of K2 HBS radial pad support
• Slide 12 shows ~16mm permanent distortion. • Supports starts to yield at 100,000 lbs radial load
(far exceeded) • MathCAD model of seismic acceleration applied
to 300T telescope estimates support saw > 150,000 lbs.
• Note: stress in UHMV pad ~70,000 psi. (yields at 5800 psi.) Bolt heads restraining pad could damage journal?
![Page 14: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/14.jpg)
FEA models of K2 hydrostatic bearing support.
• Mesh model (slide 15)
• Von-Mises Equivalent Stress (slide 16)
![Page 15: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/15.jpg)
![Page 16: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/16.jpg)
von-Mises stress(16mm deflection)
![Page 17: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/17.jpg)
FEA model of AZ journal assembly including grout
• Mesh model of grout and anchors (slide 18)• Mesh model radial support applying load to
azimuth journal (slide 19)• 300T dummy load (note does not model
overturning moment) with 0.4g acceleration (slide 20)
• Resulting Von-Mises stress in radial support (slide 21)
• Stress in grout (HBS on) (slide 22, 23)
![Page 18: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/18.jpg)
Model of grout with anchor hardware
![Page 19: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/19.jpg)
Journal bearing, grout, and radial pad support
![Page 20: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/20.jpg)
0.4 g acceleration vector
![Page 21: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/21.jpg)
Von Mises Stress (way) beyond yield strength of UHMW (5800 psi) pads and steel (70kpsi) radial pad supports
![Page 22: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/22.jpg)
Stress in grout ~3x yield stressfrictionless journal to grout
![Page 23: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/23.jpg)
Grout stress >20kpsiGrout strength ~6-8kpsi
![Page 24: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/24.jpg)
Conclusions: existing system
• In a zone 4 “rare earthquake” event: journal bearing slips
• Grout under journal yields (cracks)
• Anchor bolts securing journal bend or break.
• In zone 4 “very rare earthquake” uplift restraint failure likely (need further analysis)
![Page 25: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/25.jpg)
The azimuth journal drawings
• KE-01100 sheet 2 of 3 shows a cross section of the az bearing journal.
• The center of the telescope is to the left.
• Sheet 1 shows the top down view of the journal bearing.
![Page 26: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/26.jpg)
![Page 27: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/27.jpg)
![Page 28: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/28.jpg)
Eccentricity of track
• Tomas Krasuski et. al. measured the radial run out of az journal 3/29/2009 (slide 29)
• Based on telescope logs showing telescope position during 2006 earthquake, journal shape is elongated along direction of quake
![Page 29: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/29.jpg)
![Page 30: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/30.jpg)
What happens if HBS off? Add friction and add overturning moment due to telescope weight
above azimuth restraints.
Model parameters
• Frictional contact elements between hydrostatic pad and journal (COF= 0.08)
• Frictional contact elements between grout and journal (COF 0.45)
• dummy mass wt. 300 tons
• 150,000 lbs weight applied to top of HBS pad
• Horizontal acceleration 0.4g (154 in/s^2) in y-direction (Zone 4 rare earthquake requirement)
• Grout fixed at bottom
• Dummy telescope vertical displacement fixed (assume only horizontal displacement)
![Page 31: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/31.jpg)
FEA model results
• Mesh model showing loads
• Mesh model showing grout
• Stress in grout (beyond yield)
• Minimum principal stress (tensile) detail
![Page 32: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/32.jpg)
Course mesh modelrefined mesh at grout holes
![Page 33: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/33.jpg)
Course mesh of grout(Journal surface hidden)
Coefficient of friction (COF) COF grout-steel 0.45
COF lubed steel-steel 0.08
![Page 34: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/34.jpg)
Minimum principal stressin grout
stress concentration at anchor holes beyond yield
![Page 35: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/35.jpg)
Minimum principal stress
![Page 36: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/36.jpg)
Conceptual Design questions
• Can we spread the load over more of the journal/ anchor bolts?
• The current clearance is only ~11 mm.
• Can we increase clearance to decrease accelerations?
• (Acceleration inversely proportional to stopping distance)
![Page 37: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/37.jpg)
Conceptual Design Strategies: active control: Magneto restrictive
• An active control system is designed to induce artificial damping to the isolation structure of a building without increasing its stiffness. The control forces needed are exerted only on the base of the structure, and the system is quite practical. This control system can operate efficiently if the time delay that exists in the actual system does not exceed its critical value. The critical delay time depends on both the fundamental frequencies of the structure and the artificial damping introduced by the control system.
![Page 38: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/38.jpg)
Active Restraints
Pros: • Active isolators provide excellent energy
dissipation over a wide range of frequencies.• Damping does not add to system stiffness.• Tunable to allow improved radial stiffness during
operations yet use the maximum travel during a seismic event.
• Cons: Expensive• Complex systems: requires ultra high reliability• Must be maintained
![Page 39: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/39.jpg)
Passive restraints (Pros)
Pros: • Relatively inexpensive• Simple systems• Little maintenanceCons: • Damping increases natural frequency • Effectiveness dependant on seismic input frequencies.• Resonant maximum natural frequency close to seismic
excitation frequencies: “Reduction in transfer of vibratory forces is obtained only when the ratio of the disturbing frequency to the natural frequency is greater than 1.414”
![Page 40: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/40.jpg)
Ordinate: 2006 seismic excitation frequencies between 2-10 Hz.
Minimum stiffness (K) set by our 7/16” travel.
Abscissa: Calculated static deflection is 1.5” (just off right of chart)
It will be difficult to get above the region of “magnification factor” or resonances with passive restraints.
(Sorry, still looking for a clearer graphic.)
![Page 41: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/41.jpg)
Adding damping: ShocksDamping c is conveniently referenced to Critical Damping c c which is the value of damping at which a system will not oscillate when disturbed from equilibrium.
See: http://www.kineticsystems.com/page306.html
![Page 42: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/42.jpg)
under-damped oscillator
• Adding damping increases the “damped natural frequency”. This means we need to lower the stiffness of the system to achieve the same accelerations (fragility factor).
• This is counter productive to our goal to increase operational radial rigidity.
![Page 43: Seismic Upgrade Conceptual Design material Shawn Callahan Mike Pollard 3/2/1011](https://reader038.vdocuments.net/reader038/viewer/2022110320/56649cc05503460f94986e70/html5/thumbnails/43.jpg)
End of presentation