selection diagram... · 4g fd 1879-e7gm2k50 fc 3379-e7gm1k22 fd 874-e7m2k50 general catalog...

8
4G 79 80 79 FP FD FL FC FP 874 FD 874 FL 874 FR 874 FM 874 FX 874 FZ 874 18 9 20 21 22 33 34 General Catalog 2013-2014 4/127 Rope safety switches without reset for simple stop CONTACT BLOCKS 1NO+1NC slow action 2NC slow action 1NO+2NC slow action 3NC slow action 2NO+1NC slow action 1NO+1NC slow action 2NC slow action CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled With M12 metal connector assembled and wired With M12 plastic connector assembled and wired Selection diagram ACTUATORS ACTUATORS

Upload: others

Post on 21-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Selection diagram... · 4G FD 1879-E7GM2K50 FC 3379-E7GM1K22 FD 874-E7M2K50 General Catalog 2013-2014 4/128 Contact blocks 18 1NO+1NC, slow action 9 2NC, slow action 20 1NO+2NC, slow

4G

79 8079

FP FD FL FC

FP 874 FD 874 FL 874 FR 874 FM 874 FX 874 FZ 874

18 9 20 21

22 33 34

General Catalog 2013-20144/127

Rope safety switches without reset for simple stop

CONTACT BLOCKS 1NO+1NC

slow action 2NC

slow action1NO+2NC slow action

3NC slow action

2NO+1NC slow action

1NO+1NC slow action

2NC slow action

CONDUIT ENTRIES

Threaded conduit entries(standard)

With cable gland assembled

With M12 metal connector assembled and wired

With M12 plastic connector assembled and wired

Selection diagram

ACTUATORS ACTUATORS

Page 2: Selection diagram... · 4G FD 1879-E7GM2K50 FC 3379-E7GM1K22 FD 874-E7M2K50 General Catalog 2013-2014 4/128 Contact blocks 18 1NO+1NC, slow action 9 2NC, slow action 20 1NO+2NC, slow

4G

FD 1879-E7GM2K50

FC 3379-E7GM1K22

FD 874-E7M2K50

4/128General Catalog 2013-2014

Contact blocks

18 1NO+1NC, slow action9 2NC, slow action

20 1NO+2NC, slow action21 3NC, slow action22 2NO+1NC, slow action33 1NO+1NC, slow action 34 2NC, slow action

Actuating head

79 longitudinal head80 transversal head (only for FD-FL housing)

Threaded conduit entry

PG 13,5 (standard)

M2 M20x1,5

Contacts type

silver contacts (standard)

G silver contacts gold plated 1 µm

Housing

FD metal housing, one conduit entryFL metal housing, three conduit entriesFP polymer housing, one conduit entry

Contacts type

silver contacts (standard)

G silver contacts gold plated 1 µm

Contact blocks

33 1NO+1NC, slow action

34 2NC, slow action

Threaded conduit entry

PG 11 (standard)

M1 M16x1,5

Housing

FC metal housing, one conduit entry

Actuating head

79 longitudinal head

80 transversal head

Contact blocks

8 1NC, slow action Threaded conduit entry

PG 13,5 (standard)

A PG 11 (only for FR-FX housing)

M1 M16x1,5 (only for FR-FX housing)

M2 M20x1,5

Housing

FD metal housing, one conduit entryFL metal housing, three conduit entriesFP polymer housing, one conduit entryFR polymer housing, one conduit entryFM metal housing, one conduit entryFX polymer housing, two conduit entriesFZ metal housing, two conduit entries

Code structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office.

article options

article options

article options

Actuating force

standardE7 initial 20 N...final 40 N (only for head 79)

E9 initial 13 N...final 75 N (only for head 80)

Actuating force

standardE7 initial 20 N...final 40 N (only for head 79)

E9 initial 13 N...final 75 N (only for head 80)

Actuating force

standardE7 initial 20 N...final 40 N

Preinstalled cable gland

no cable gland (standard)

K22 with assembled cable gland suitable for Ø 5 to Ø 10 mm cables range

K26 with assembled cable gland suitable for Ø 3 to Ø 7 mm cables range

Preinstalled cable gland or connectors

no cable gland or connector (standard)

K21 with assembled cable gland suitable for Ø 6 to Ø 12 mm cables range

... ........................

K50 with assembled 5 poles M12 metal connector

... ........................For the complete list of all combinations, please contact our technical office.

Preinstalled cable gland or connectors

no cable gland or connector (standard)

K21 with assembled cable gland suitable for Ø 6 to Ø 12 mm cables range

... ........................

K50 with assembled 5 poles M12 metal connector

... ........................For the complete list of all combinations, please contact our technical office.

Page 3: Selection diagram... · 4G FD 1879-E7GM2K50 FC 3379-E7GM1K22 FD 874-E7M2K50 General Catalog 2013-2014 4/128 Contact blocks 18 1NO+1NC, slow action 9 2NC, slow action 20 1NO+2NC, slow

4G

Technical data

General Catalog 2013-20144/129

Cross section of the conductors (flexible copper wire)Contact blocks 20, 21, 22, 33, 34: min. 1 x 0,34 mm2 (1 x AWG 22) max. 2 x 1,5 mm2 (2 x AWG 16)Contact blocks 18, 8, 9: min. 1 x 0,5 mm2 (1 x AWG 20) max. 2 x 2,5 mm2 (2 x AWG 14)

Electrical data Utilization categories

Alternate current: AC15 (50...60 Hz)Ue (V) 250 400 500Ie (A) 6 4 1Direct current: DC13Ue (V) 24 125 250Ie (A) 6 1,1 0,4

Alternate current: AC15 (50...60 Hz)Ue (V) 24 120 250Ie (A) 4 4 4Direct current: DC13Ue (V) 24 125 250Ie (A) 4 1,1 0,4

Thermal current (Ith): 4 ARated insulation voltage (Ui): 250 Vac 300 VdcProtection against short circuits: fuse 4 A 500 V type gGPollution degrees: 3

with

4 o

r 5

pole

sM

12 c

onne

ctor

Thermal current (Ith): 2 ARated insulation voltage (Ui): 30 Vac 36 VdcProtection against short circuits: fuse 2 A 500 V type gGPollution degrees: 3w

ith 8

pol

esM

12 c

onne

ctor

Alternate current: AC15 (50...60 Hz)Ue (V) 24 Ie (A) 2 Direct current: DC13Ue (V) 24 Ie (A) 2

with

out

conn

ecto

r

HousingHousing type FP, FR and FX made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic Housing type FD, FL, FC, FM and FZ made of metal, coated with baked epoxy powder.FD, FP, FC, FR and FM series one conduit entryFX and FZ series two conduit entriesFL series three conduit entries Protection degree: IP67 according to EN 60529 with cable gland having equal or higher protection degree

General dataFor safety applications up to SIL 3 / PL eSafety parameters: see page 7/34Ambient temperature: from -25°C to +80°CVersion for operation in ambient temperature from -40°C to +80° C on request

Max actuation frequency: 1 operation cycles / 6 sMechanical endurance: 1 million of operations cycles1

Max actuating speed: 0,5 m/s Min. actuating speed: 1 mm/sDriving torque for installation: see pages 7/1-7/12(1) One operation cycle means two movements, one to close and one to open contacts, as foreseen by EN 60947-5-1 standard..

Main data

Metal or polymer housing, from one to three conduit entries

Protection degree IP67

7 contact blocks available

Transversal head or longitudinal head versions

M12 assembled connector versions

Silver contacts gold plated versions

Several accessories available

Rope safety switches without reset for simple stop

Markings and quality marks:

Approval IMQ: EG605 (FD-FL-FC series) EG606 (FP series) EG610 (FR-FX-FK series) EG609 (FM-FZ series)Approval UL: E131787Approval CCC: 2007010305230000 (FD-FL-FC series) 2007010305230014 (FP series) 2007010305230013 (FR-FX-FK series) 2007010305229998 (FM-FZ series)Approval EZU: 1010151Approval GOST: POCC IT.AB24.B04512

In conformity with requirements requested by: Low Voltage Directive 2006/95/EC, Machinery Directive 2006/42/EC and Electromagnetic Compatibility 2004/108/EC.Positive contact opening in conformity with standards: IEC 60947-5-1, EN 60947-5-1, VDE 0660-206.

In conformity with standards:IEC 60947-5-1, EN 60947-5-1, EN 60947-1, IEC 60204-1, EN 60204-1, EN 1088, EN ISO 12100-1, EN ISO 12100-2, IEC 60529, EN 60529, NFC 63-140, VDE 0660-200, VDE 0113.Approvals:IEC 60947-5-1, UL 508, GB14048.5-2001.

If not expressly indicated in this chapter, for the right installation and the correct utilization of all articles see requirements indicated from page 7/1 to page 7/12.

Thermal current (Ith): 10 ARated insulation voltage (Ui): 500 Vac 600 Vdc 400 Vac 500 Vdc (contact blocks 20, 21, 22, 33, 34) Rated impulse withstand voltage (Uimp): 6 kV 4 kV (contact blocks 20, 21, 22, 33, 34)Conditional shot circuit current: 1000 A according to EN 60947-5-1Protection against short circuits: fuse 10 A 500 V type aMPollution degree: 3

Page 4: Selection diagram... · 4G FD 1879-E7GM2K50 FC 3379-E7GM1K22 FD 874-E7M2K50 General Catalog 2013-2014 4/128 Contact blocks 18 1NO+1NC, slow action 9 2NC, slow action 20 1NO+2NC, slow

4G

4/130General Catalog 2013-2014

These rope operated safety switches are installed on machines or conveyor belts, to activate the simple stop of the machine on every hand intervention on the rope, from any point.Provided with self-control function, they constantly check their correct working operation, signalling with the opening of the contacts an eventual loosening or breaking of the rope.

Please contact our technical service for the list of approved products.

Please contact our technical service for the list of approved products.

Data type approved by ULRated insulation voltage (Ui): 500 Vac 400 Vac (for contact blocks 20, 21, 22, 33, 34) Thermal current (Ith): 10 AProtection against short circuits: fuse 10 A 500 V type aMRated impulse withstand voltage (Uimp): 6 kV 4 kV (for contact blocks 20, 21, 22, 33, 34)Protection degree: IP67MV terminals (screw clamps)Pollution degrees 3Utilization category: AC15Operation voltage (Ue): 400 Vac (50 Hz)Operation current (Ie): 3 AForms of the contact element: Zb, Y+Y, Y+Y+X, Y+Y+Y, Y+X+XPositive opening of contacts on contact block 18, 8, 9, 20, 21, 22, 33, 34

In conformity with standards: EN 60947-1, EN 60947-5-1+ A1:2009, fundamental requirements of the Low Voltage Directive 2006/95/CE.

Description

Rotating headsRemoving the four fastening screws, in all switches, it is possible to rotate the head in 90° steps.

The switches (head 79 and 80) are provided with a green ring that shows the area of the correct stretching of the rope. The installer has only to stretch the rope until the black indicator will be in the middle of the green area. If a traction (or loosening ) of the rope it is high enough to permit the black indicator to go outside

the correct stretching area, there will be the opening of the safety contacts.

Rope regulation point indicator

Area of correct rope stretching

Stretching indicator

Data type approved by IMQ, CCC and EZUUtilization categories Q300 (69 VA, 125-250 Vdc) A600 (720 VA, 120-600 Vac)Data of the housing type 1, 4X “indoor use only”, 12, 13For all contact blocks use 60 or 75 °C copper (Cu) conductor and wire size No. 12-14 AWG. Terminal tightening torque of 7,1 lb in (0.8 Nm).

In conformity with standard: UL 508

Page 5: Selection diagram... · 4G FD 1879-E7GM2K50 FC 3379-E7GM1K22 FD 874-E7M2K50 General Catalog 2013-2014 4/128 Contact blocks 18 1NO+1NC, slow action 9 2NC, slow action 20 1NO+2NC, slow

18 L

9 L

20 L

21 L

22 L

33 L

34 L

18 L

9 L

20 L

21 L

22 L

33 L

34 L

4G

2828

4030

39

16

16

72

138

606305.3

5.3x

7.3

60

15

303040

726.

5

138.

5

28

38

28

16

5.3

5.3x

7.3

22

32

20

84

16

15

30

30

40

38

5.3

606.

5

5.3x7.3

28

28

56

57

18

40

33

7212

9

6

14.5

14.5

5.3x6.3

57

18

406

56 33

2232

2084

14.5

14.5

89

5.2x6.2

28

28

40

28.5

4472

116

14.5

14.5

33

5.5

40

84

2232

30

20 14.5

28.5

3314.5

5.544

76

23-24

11-120 8.57.5

2 8S

41.5

7

FP 1879 1NO+1NC

FP 979 2NC

FP 2079 1NO+2NC

FP 2179 3NC

FP 2279 2NO+1NC

FP 3379 1NO+1NC

FP 3479 2NC

FD 1879 1NO+1NC

FD 979 2NC

FD 2079 1NO+2NC

FD 2179 3NC

FD 2279 2NO+1NC

FD 3379 1NO+1NC

FD 3479 2NC

FD 1880 1NO+1NC

FD 980 2NC

FD 2080 1NO+2NC

FD 2180 3NC

FD 2280 2NO+1NC

FD 3380 1NO+1NC

FD 3480 2NC

FL 1879 1NO+1NC

FL 979 2NC

FL 2079 1NO+2NC

FL 2179 3NC

FL 2279 2NO+1NC

FL 3379 1NO+1NC

FL 3479 2NC

FC 3379 1NO+1NC

FC 3479 2NC

FC 3380 1NO+1NC

FC 3480 2NC

FL 1880 1NO+1NC

FL 980 2NC

FL 2080 1NO+2NC

FL 2180 3NC

FL 2280 2NO+1NC

FL 3380 1NO+1NC

FL 3480 2NC

Min. force

Travel diagrams

Min. force

Travel diagrams

Accessories See page 6/1

General Catalog 2013-20144/131

Initial 63 N...Final 83 N (90 N )

page 4/132 - group 1

Initial 63 N...Final 83 N (90 N )

page 4/132 - group 1

Initial 147 N...Final 235 N (250 N )

page 4/132 - group 2

Initial 63 N...Final 83 N (90 N )

page 4/132 - group 1

Initial 63 N...Final 83 N (90 N )

page 4/132 - group 1

Initial 147 N...Final 235 N (250 N )

page 4/132 - group 2

Initial 147 N...Final 235 N (250 N )

page 4/132 - group 2

Dimensional drawings

NO opening

Max travel

NC closing Positive opening travel

Closed contact

Open contact

Ideal rope tension pointIMPORTANT: In safety applications it is necessary to activate the switch at least up to the positive opening point indicated in the diagrams with the symbol . Operate the switch at least with the positive opening force, indicated between brackets, below each article, next the value of minimum force.

How to read travel diagrams All measures in the diagrams are in mm

Example diagram

All measures in the drawings are in mm

Contacts type:

L = slow action

Contact blocks

Contact blocks

Min. force

Travel diagrams

Min. force

Travel diagrams

Rope safety switches without reset for simple stop

Page 6: Selection diagram... · 4G FD 1879-E7GM2K50 FC 3379-E7GM1K22 FD 874-E7M2K50 General Catalog 2013-2014 4/128 Contact blocks 18 1NO+1NC, slow action 9 2NC, slow action 20 1NO+2NC, slow

4G

8 L

8 L

2022 24.2

51.5

30.8 30.8

14.2

38.8

15.3

108.

6

12.2

3 4.2x7.2

3

30.8 31.5

24.22022

12.2

14.2

54.4

38.8

15.3

111.

5

4.2x7.2

18.5

45

20224042

4

3

58

5611 24.2

14.231.7

46.1

15.3

12.2

3

50

24.2

31.5

18.5

45

14.2

12.2

38.8

102.

115

.3

4.2x7.2

20224042

15.3

18.5332

.360

6

30116.

6

40

5.3

5.3x7.3

16

16

3039

32.1

30

15.3

116.

9

18.53

40 15.2

16

30

38

6.5

60

5.3

5.3x7.3

18.5315

.3

7

40

5732

.1

107

18

56

5.3x6.3

14.5

14.5

33

6

FR 874 1NC FM 874 1NC FX 874 1NC

181NO+1NC

0 8.57

7.4

1.5

1.1 8S

4 0 16133.5

4 12.6 14S

8

81NC

0

6.3

8.51 8

S

4

92NC

0 8.5

7.21.4

8

S

4 0

133.5

14.5

S

8 16

201NO+2NC

0 8.571.5

7.41.1

8

S

4 0 16

133.5

3.8 12.614

S

8

213NC

0 8.5

71.5

8

S

4 0 163.5 12.614

S

8

222NO+1NC

0 8.571.5

7.41.1

8

S

4 0

133.5

3.8 12.614

S

8 16

331NC+1NO

0 8.57

7.4

1.5

1.1 8S

4 0 16

133.5

3.8 12.614

S

8

342NC

0 8.5

71.5

8

S

4 0 163.8 12.614

S

8

FZ 874 1NC

FP 874 1NC FD 874 1NC FL 874 1NC

4/132General Catalog 2013-2014

Travel diagrams table

Initial 63 N...Final 83 N (90 N )

page 4/132 - group 3

Initial 63 N...Final 83 N (90 N )

page 4/132 - group 3

Initial 63 N...Final 83 N (90 N )

page 4/132 - group 3

Initial 63 N...Final 83 N (90 N )

page 4/132 - group 3

Initial 63 N...Final 83 N (90 N )

page 4/132 - group 3

Initial 63 N...Final 83 N (90 N )

page 4/132 - group 3

Initial 63 N...Final 83 N (90 N )

page 4/132 - group 3

Contacts type:

L = slow action

Contact blocks

Contact blocks

Min. force

Travel diagrams

Min. force

Travel diagrams

Contact blocksGroup 1 Group 2 Group 3

In the rest position (with rope correctly tightened) the two contacts of contact block 8 are both closed and are activated respectively by actuating or loosening the rope. In order to use this contact block for safety applications is necessary to connect the two contacts in series. For this reason in wiring diagrams the contact block 8 is indicated as 1NC, whereas in travel dia-grams are indicated both contacts.

Items with code on the green background are available in stock

Page 7: Selection diagram... · 4G FD 1879-E7GM2K50 FC 3379-E7GM1K22 FD 874-E7M2K50 General Catalog 2013-2014 4/128 Contact blocks 18 1NO+1NC, slow action 9 2NC, slow action 20 1NO+2NC, slow

4G

50 m MAX

3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m

FD

188

0F

D 1

880

FD

188

0

70 m MAX

3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m

FD

188

0

FD

188

0

16 m MAX

35 m MAX

3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m

FD 1879

18 m MAX

2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m

FD 1879

24 m MAX

2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m

FD 1879

6 m MAX

FD 1879

12 m MAX

2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m

FD 1879

FD 1880

5 m max 5 m max

FD 1879

FD 874

3 m max 3 m max

General Catalog 2013-20144/133

Application examples and max rope length for switches with longitudinal heads

VF AF-ME78

Application examples and max rope length for switches with transversal heads

VF AF-TR5 VF AF-MR5

VF AF-MR5VF AF-TR5

VF AF-TR5 VF AF-MR5

VF AF-MR5VF AF-TR5

VF AF-ME80

VF AF-TR5 VF AF-MR5

VF AF-MR5VF AF-TR5

VF AF-TR5 VF AF-MR5

VF AF-MR5VF AF-TR5

Example A

Example B

Example C

Example D

Example F

Example G

Example H

Example I

Example J

PulleyVF AF-TR8

Pulley

Example E

VF AF-TR8

VF AF-MR5

VF AF-MR5

Rope safety switches without reset for simple stop

Page 8: Selection diagram... · 4G FD 1879-E7GM2K50 FC 3379-E7GM1K22 FD 874-E7M2K50 General Catalog 2013-2014 4/128 Contact blocks 18 1NO+1NC, slow action 9 2NC, slow action 20 1NO+2NC, slow

4G

0

5

10

15

20

25

30

0 10 20 30 40 50 60 70 80 90 100

0

10

20

30

40

50

60

70

80

0 10 20 30 40 50 60 70 80 90 100

4/134General Catalog 2013-2014

Max rope length

Max rope length for switches with longitudinal heads

Max

leng

ths

of t

he r

ope

(m)

Thermal differential (°C)

Max rope length for switches with transversal heads

Max

leng

ths

of t

he r

ope

(m)

Thermal differential (°C)

Important: The above data are guaranteed only using original rope and accessories. See page 4/135.

example Aexample B

example C-Eexample D

example Fexample G

example H-Jexample I

In the diagram, the suggested max. rope lengths with regard to changes of temperature (thermal differential) to which the switch is expected to be exposed in the working area are indicated.For instance, for an example C installation which expects a thermal differential of 30°C, a max rope length of 10 meters is suggested.

Adjusting of intervention point

For switches with head 79 and 80: Stretch the rope connected to the switch, until the end of the indicator (1)

reaches about the middle of the green ring (2).

For switches with head 74: stretch the rope connected to the switch till the thimble will be at about 4 mm from

the head.