sendate-extend€¦ · source: nyteknik 2012 mega datacenter complexity . project idea . secure...

23
SENDATE-EXTEND Adj. prof. Tor Björn Minde, CEO SICS North Swedish ICT AB (Head of Strategy Ericsson Research) An EUREKA Celtic-plus project

Upload: others

Post on 22-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

SENDATE-EXTEND

Adj. prof. Tor Björn Minde, CEO SICS North Swedish ICT AB (Head of Strategy Ericsson Research)

An EUREKA Celtic-plus project

Page 2: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

MARKET TRENDS

Page 3: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

The digitalization looks like the industrialization

• Digitalization – traditional industries

• Data – great amount, owned & shared

• Things – connected and intelligent

• Communications – faster and more

• Users – active and enhanced • Functions – More and seamless

A new industry era and transformation

Page 4: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

Type Response times

Data amount

Traffic amount

Cache DC location

Cold storage seconds Gigabytes Mb/s remote

Off-line big data crunching seconds Gigabytes Gb/s remote

Chat/IoT type communication 100th milliseconds kilobytes kb/s remote

Web/app rendering 100th milliseconds Megabytes Mb/s Yes remote

Streaming 10th milliseconds Gigabytes Mb/s Yes mix

Real-time conferencing 10th milliseconds Megabytes Mb/s Yes mix

Real-time analytics milliseconds Megabytes Gb/s proximity

Transaction based/Control loops

milliseconds kilobytes kb/s proximity

Application characteristics

Page 5: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

Source: Nyteknik 2012

Mega datacenter complexity

Page 6: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

PROJECT IDEA

Page 7: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions

Improve efficiency and flexibility of deployment, monitoring, operations, maintenance and management of storage, compute, communication and

energy supply infrastructure within datacenters and in a distributed cloud.

SENDATE – EXTEND

19.10.2016 12

Page 8: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions

Improve efficiency and flexibility of operating all different parts

within datacenters and in a distributed cloud.

SENDATE – EXTEND

19.10.2016 13

Page 9: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

EXTEND – Holistic Datacenter Automation

19.10.2016 16

Control Control Control Control Control

Bu

ild

ing

Po

we

r

Co

olin

g

IT H

ard

wa

re

Ne

two

rkin

g

Ass

um

ptio

ns

Ass

um

ptio

ns

Ass

um

ptio

ns

Ass

um

ptio

ns

Control

IT S

oft

wa

re

Ass

um

ptio

ns

Control

Ap

plic

atio

n

Ass

um

ptio

ns

Page 10: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

EXTEND – Holistic Datacenter Automation

19.10.2016 17

Control Control Control Control Control

Bu

ild

ing

Po

we

r

Co

olin

g

IT H

ard

wa

re

Ne

two

rkin

g

Kn

ow

led

ge

Kn

ow

led

ge

Kn

ow

led

ge

Kn

ow

led

ge

Control

IT S

oft

wa

re

Kn

ow

led

ge

Control

Ap

plic

atio

n

Kn

ow

led

ge

Common Policies, Shared Data(base), Common Optimization Criteria

Page 11: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

SICS ICE – A PROJECT RESOURCE

Page 12: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

In operation since January 2016. 500 GB of metrics data now

SICS-ICE Room-in-room module 1

Page 13: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

Under construction. Ready for use January 2017

SICS-ICE room-in-room module 2

Page 14: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

A FEW USE-CASES

Page 15: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

The architecture enables to dynamically establish lightpath between racks in different DCs

• Impact of various abstraction policies (for the intra- and inter-DC resources) on the provisioning of ToR to ToR connectivity

• Protection and restoration strategies of provisioned cloud services based on the concept of VM migration

Converged architecture for geographically distributed metro DCs

Page 16: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

19.10.2016 29

SLA violation detection using model

Build SLA prediction model

Fault localizer (Localize faulty nodes)

Fault classification (manually or automated)

Actuation /Orchestration of system resources

OAM data from PMs and VMs

Data Pre-processor / Feature Engineer

Fa

ult D

ete

ctio

n

Fa

ult L

oc

aliza

tio

n

Cloud Monitoring System

RCA Analytics

Cloud Infrastructure

Fault localizer (Localize performance faults in a faulty node)

Alarm generating approaches:

• Complete GT availability

• SLA violation detection using predictions

• SLA violation forecasting

• Anomaly detection

•Fault/Anomaly Localization:

•Detecting faulty nodes

•Detecting faulty metrics

Calculate Actuation parameters

•Resource requirement prediction

Root Cause Analytics based on metric correlation

Source Ericsson

Page 17: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

Metrics ”backbone”

19.10.2016 30

”Zafka”

”Defka”

”Xxfka” Other systems

Page 18: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

19.10.2016 31

Metrics database

Asset management

Data collection

Asset positioning

Failure detection

Light-weight application

Maintenance application

Page 19: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

IT load vs Cooling

Use Case 1 - IT load vs CoolingMethod

Month DD, Year | Slide 4

© ABB Group

IT load scheduling analysis over a period to

find IT load pattern

Dynamic cooling control in zone-

level or rack-level

A tool to provide relations

among CRAHs and individual

racks and a degree of influence

Simulate a

number of cooling

strategies- Dynamic cooling, flow, T

- IT load shifting

- Distributed air flow

- Shutter flow control

IT load analysis over 48 hours to present IT load,

cooling load and server temperature variations

Source ABB

Page 20: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

PROJECT FACTS

Page 21: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

Project partners

19.10.2016 37

Large enterprises Medium enterprises

Small enterprises Academia Financial support

Page 22: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

Project budget

19.10.2016 38

Page 23: SENDATE-EXTEND€¦ · Source: Nyteknik 2012 Mega datacenter complexity . PROJECT IDEA . SEcure Networking for a DATa center cloud in Europe – EXTENded Datacenter solutions Improve

supported by