Sira Certification Service Rake Lane, Eccleston, Chester, CH4 9JN, England Tel: +44 (0) 1244 670900 Fax: +44 (0) 1244 681330 Email: [email protected] Web: www.siracertification.com CERTIFICATION Project Number 21346 D R Stubbings BA MIET C. Index 14 Certification Manager This certificate and its schedules may only be reproduced in its entirety and without change. Page 1 of 3 Form 9400 Issue 1 1 EC TYPE-EXAMINATION CERTIFICATE 2 Equipment intended for use in Potentially Explosive Atmospheres Directive 94/9/EC 3 Certificate Number: Sira 02ATEX3291 Issue: 3 4 Equipment: Universal Gas Sensors 5 Applicant: General Monitors (Ireland) Ltd General Monitors Inc 6 Address: Ballybrit Industrial Estate Galway Ireland 26776 Simpatica Circle Lake Forest California USA 7 This equipment and any acceptable variation thereto is specified in the schedule to this certificate and the documents therein referred to. 8 Sira Certification Service, notified body number 0518 in accordance with Article 9 of Directive 94/9/EC of 23 March 1994, certifies that this equipment has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of equipment intended for use in potentially explosive atmospheres given in Annex II to the Directive. The examination and test results are recorded in the confidential reports listed in Section 14.2. 9 Compliance with the Essential Health and Safety Requirements, with the exception of those listed in the schedule to this certificate, has been assured by compliance with the following documents: EN 50014:1997 (Amendments A1 & A2) EN 50018:2000 EN 50019:2000 10 If the sign ‘X’ is placed after the certificate number, it indicates that the equipment is subject to special conditions for safe use specified in the schedule to this certificate. 11 This EC type-examination certificate relates only to the design and construction of the specified equipment. If applicable, further requirements of this Directive apply to the manufacture and supply of this equipment. 12 The marking of the equipment shall include the following: HC Detector Head Assembly: II 2 G EEx ed IIC T4 Ta -40°C to +75°C EEx ed IIC T3 Ta -40°C to +120°C HC Hi-Temp Detector Head Assembly: II 2 G EEx ed IIC T2 Ta -40°C to +180°C H 2 S Detector Head Assembly: II 2 G EEx ed IIC T4 Ta -40°C to +75°C

Upload: adrian-laureniu-radulescu

Post on 26-Oct-2015

139 views

Category:

Documents


7 download

DESCRIPTION

Datasheet

TRANSCRIPT

Page 1: SENSOR J-BOX- 02ATEX3291Iss_3.pdf

Sira Certification Service Rake Lane, Eccleston, Chester, CH4 9JN, England Tel: +44 (0) 1244 670900 Fax: +44 (0) 1244 681330 Email: [email protected] Web: www.siracertification.com

C E R T I F I C A T I O N

Project Number 21346 D R Stubbings BA MIET C. Index 14 Certification Manager This certificate and its schedules may only be reproduced in its entirety and without change. Page 1 of 3 Form 9400 Issue 1

1 EC TYPE-EXAMINATION CERTIFICATE 2 Equipment intended for use in Potentially Explosive Atmospheres Directive 94/9/EC 3 Certificate Number: Sira 02ATEX3291 Issue: 3 4 Equipment: Universal Gas Sensors 5 Applicant: General Monitors (Ireland) Ltd General Monitors Inc 6 Address: Ballybrit Industrial Estate

Galway Ireland

26776 Simpatica Circle Lake Forest California USA

7 This equipment and any acceptable variation thereto is specified in the schedule to this certificate and

the documents therein referred to. 8 Sira Certification Service, notified body number 0518 in accordance with Article 9 of Directive 94/9/EC

of 23 March 1994, certifies that this equipment has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of equipment intended for use in potentially explosive atmospheres given in Annex II to the Directive.

The examination and test results are recorded in the confidential reports listed in Section 14.2. 9 Compliance with the Essential Health and Safety Requirements, with the exception of those listed in the

schedule to this certificate, has been assured by compliance with the following documents:

EN 50014:1997 (Amendments A1 & A2) EN 50018:2000 EN 50019:2000 10 If the sign ‘X’ is placed after the certificate number, it indicates that the equipment is subject to special

conditions for safe use specified in the schedule to this certificate. 11 This EC type-examination certificate relates only to the design and construction of the specified

equipment. If applicable, further requirements of this Directive apply to the manufacture and supply of this equipment.

12 The marking of the equipment shall include the following:

HC Detector Head Assembly:

II 2 G EEx ed IIC T4 Ta -40°C to +75°C EEx ed IIC T3 Ta -40°C to +120°C

HC Hi-Temp Detector Head Assembly:

II 2 G EEx ed IIC T2 Ta -40°C to +180°C

H2S Detector Head Assembly:

II 2 G EEx ed IIC T4 Ta -40°C to +75°C

Page 2: SENSOR J-BOX- 02ATEX3291Iss_3.pdf

Sira Certification Service Rake Lane, Eccleston, Chester, CH4 9JN, England Tel: +44 (0) 1244 670900 Fax: +44 (0) 1244 681330 Email: [email protected] Web: www.siracertification.com

C E R T I F I C A T I O N

SCHEDULE EC TYPE-EXAMINATION CERTIFICATE Sira 02ATEX3291 Issue 3

This certificate and its schedules may only be reproduced in its entirety and without change. Page 2 of 3 Form 9400 Issue 1

13 DESCRIPTION OF EQUIPMENT

The Universal Gas Sensors are intended to monitor combustible gases. They comprise a detector head assembly and a junction box. The detector head assembly has three variants: the HC Detector Head; the HC Hi-Temp Detector Head; the H2S Detector Head. All the detector head assembly variants utilise the same enclosure with only the internal components and arrangement differing. The sensor heads are manufactured from stainless steel and are cylindrical in shape with a hexagonal shoulder in the middle. The front end of the sensor head enclosure has a 250 μm sinter fused into its walls to allow penetration of the surrounding atmosphere and the appropriate presence of the relevant gas to be detected. The rear end of the sensor head contains Stycast 2850 FT Catalyst 11 setting compound through which the equipment wiring passes. The rear end of the sensor head also has a male ¾”-14 NPT thread-form to allow the sensor head to be mounted into a GB range component approved increased safety junction box manufactured by Bartec. The junction box contains an MK6.6 component approved increased safety terminal block manufactured by Klippon Microsystems.

Design options

Alternative setting compound: The HC Hi-Temp Detector Head Assembly utilises Stycast 2762 Catalyst

17. Alternative terminals: The HC Hi-Temp Detector Head Assembly utilises Type Ker-Ex

component approved increased safety terminals manufactured by Phoenix Contact GmbH & Co.

Alternative junction box: The HC Hi-Temp Detector Head Assemblies utilises a 07-5180

component approved increased safety junction box manufactured by Bartec.

Variation 1 - This variation introduced the following changes:

i. To permit the introduction of minor drawing modifications that include additional information

that is relevant to other approvals.

Variation 2 - This variation introduced the following changes:

i. To permit the removal of entry hole options M25 ISO x 1.5 and PG13.5 from the machined Hi-Temp Junction Box.

Variation 3 - This variation introduced the following changes:

i. The recognition of a drawing replacement to correct a typographical error, drawing number

B13-021 shall be replaced by drawing number B13-022.

Page 3: SENSOR J-BOX- 02ATEX3291Iss_3.pdf

Sira Certification Service Rake Lane, Eccleston, Chester, CH4 9JN, England Tel: +44 (0) 1244 670900 Fax: +44 (0) 1244 681330 Email: [email protected] Web: www.siracertification.com

C E R T I F I C A T I O N

SCHEDULE EC TYPE-EXAMINATION CERTIFICATE Sira 02ATEX3291 Issue 3

This certificate and its schedules may only be reproduced in its entirety and without change. Page 3 of 3 Form 9400 Issue 1

14 DESCRIPTIVE DOCUMENTS 14.1 Drawings

Refer to Certificate Annexe. 14.2 Associated Sira Reports and Certificate History

Issue Date Report number Comment 0 02 Apr 2003 R51A9354A The release of prime certificate.

Re-issued 27 May 2003 to correct a typographical error 1 04 Aug 2005 R51A13733A The introduction of Variation 1. 2 25 Oct 2005 R51A14004A The introduction of Variation 2. 3 11 May 2010 R21346A/00 This Issue covers the following changes:

• All previously issued certification was rationalised into a single certificate, Issue 3, Issues 0 to 2 referenced above are only intended to reflect the history of the previous certification and have not been issued as documents in this format.

• The introduction of Variation 3. 15 SPECIAL CONDITIONS FOR SAFE USE (denoted by X after the certificate number)

None 16 ESSENTIAL HEALTH AND SAFETY REQUIREMENTS OF ANNEX II (EHSRs) The relevant EHSRs that are not addressed by the standards listed in this certificate have been

identified and individually assessed in the reports listed in Section 14.2. 17 CONDITIONS OF CERTIFICATION 17.1 The use of this certificate is subject to the Regulations Applicable to Holders of Sira Certificates. 17.2 Holders of EC type-examination certificates are required to comply with the production control

requirements defined in Article 8 of directive 94/9/EC.

17.3 The certificate relies on the following previously certified products. When they are used as part of the Universal Gas Sensors the key attributes listed below shall still be maintained by their original certificate.

Description Certificate Number Key Attributes General Monitors Type HC, HC Hi-Temp & H2S Sensor Heads Sira 00ATEX1039U EEx d IIC Bartec Type GB Junction Box BAS 98ATEX3090X EEx e II Bartec 07-5180 Junction Box Enclosure BAS 75127/B/11

PTB Ex90C3182U EEx e II

Klippon Microsystems MK Range Terminals BAS 99ATEX2123U EEx e II Phoenix Contact Ker-Ex Range Terminals BAS 90C3200U EEx e II

Page 4: SENSOR J-BOX- 02ATEX3291Iss_3.pdf

Sira Certification Service Rake Lane, Eccleston, Chester, CH4 9JN, England Tel: +44 (0) 1244 670900 Fax: +44 (0) 1244 681330 Email: [email protected] Web: www.siracertification.com

C E R T I F I C A T I O N

Certificate Annexe Certificate Number: Sira 02ATEX3291 Equipment: Universal Gas Sensors Applicant: General Monitors (Ireland) Ltd

This certificate and its schedules may only be reproduced in its entirety and without change.

Page 1 of 1 Form 9400 Issue 1

Issue 0 Drawing No.: Sheets Rev. Date: Description B13-020 1 of 1 B 30 Sep 02 Detector Head Assembly Universal Sensor, Combustible B13-021 1 of 1 B 02 Apr 98 Detector Head Assy Universal HC Hi-Temp Sensor, M20 B14-020 1 of 1 B 30 Sep 02 Detector Head Assembly Universal Sensor, Hydrogen

Sulphide 10081 1 of 3 G 01 Apr 02 Sensor Nameplate Universal Sensor 10081 2 of 3 G 01 Apr 02 Sensor Nameplate Universal Sensor 10081 3 of 3 G 01 Apr 02 Sensor Nameplate Universal Sensor 10544 1 of 1 D 29 Sep 02 Hi-Temp Junction Box Machined Issue 1 Drawing No. Sheets Rev. Date (Sira stamp) Description B13-020 1 of 1 C 03 Aug 05 Detector Head Assembly, Universal Sensor, Combustible B13-021 1 of 1 D 03 Aug 05 Detector Head Assy, Universal HC HI-Temp Sensor, M20 B14-020 1 of 1 C 03 Aug 05 Detector Head Assembly, Universal Sensor, Hydrogen

Sulphide Issue 2 Drawing No. Sheets Rev. Date (Sira stamp) Description 10544 1 of 1 E 13 Oct 05 Hi-Temp Junction Box Machined Issue 3 Drawing No. Sheets Rev. Date (Sira stamp) Description B13-022 1 of 1 A 01 Apr 10 Detector Head Assy Universal IIC Hi-Temp Sensor M20