sentry series remote telemetry units - iclinks.com sales... · 2014-12-19 · sentry series rtus...

6
Sentry Series Remote Telemetry Units Industrial Control Links, Inc. Ethernet I/O Wireless I/O Cellular I/O Serial I/O Data Logging Alarming

Upload: others

Post on 15-Mar-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Sentry Series Remote Telemetry Units - iclinks.com sales... · 2014-12-19 · Sentry Series RTUs Features & Benefits Smart & Economical Connectivity Easily connect to nearly any SCADA

Sentry Series Remote Telemetry Units

Industrial Control Links, Inc.

Ethernet I/o

Wireless I/o

Cellular I/o

Serial I/o

Data Logging

Alarming

Page 2: Sentry Series Remote Telemetry Units - iclinks.com sales... · 2014-12-19 · Sentry Series RTUs Features & Benefits Smart & Economical Connectivity Easily connect to nearly any SCADA

Sentry Series RTUs Features & Benefits Smart & Economical Connectivity

Easily connect to nearly any SCADA device, PLC or process control instrument.

Built-in Ethernet provides a high-speed means of configuration and back-up, and the ability to transfer information as registers and files. Configurable user screens provide a low-cost simple HMI which also allows for viewing trend graphs and downloading spreadsheet files. Serial communications includes hardwired and wireless technologies for register exchanges. Cellular wireless provides both register exchange capabilities, alarming and HMI access by text messaging.

Ethernet Networking

MoDBuS TCPIP/uDP

SDX

HTTP

TFTP

Data Storage

Replace expensive PC software or make sure that critical data is never lost when a communications link is down.

Data is logged to an internal flash disk, then displayed as tables and graphs in auto-generated web pages. Logged data can be downloaded into Excel or to your local PC.

Historical Trending & Data Logging

HISToRICAL TRENDING DoWN To 1 SEC

TREND uP To 16 VARIABLES

LoG 4 ToTALS EVERY MINuTE FoR THE LAST HouR

LoG 4 HouRLY ToTALS FoR oVER 5 YEARS

REALTIME ToDAY, YESTERDAY AND PEAK MINuTE, HouR, DAY ToTALS

AuTo GENERATED WEB TREND AND LoG DISPLAYS

PLoT, PAN, ZooM TRENDS AND ToTALS IN LoCAL GRAPHS

DoWNLoAD TREND AND ToTALS To CSV

Alarm Notification

Versatile, 3-state alarm management included— replace alarm dialers & expensive PC software.

TEXT MESSAGE ALARMS AND ACKNoWLEDGMENT

uP To 30 CoNFIGuRABLE ALARMS

8 CoNFIGuRABLE ALARM DESTINATIoNS

TIME oF DAY AND DAY oF WEEK SCHEDuLING

REALTIME ALARM STATuS DISPLAY oN WEB AND VIEWPoINT II HMIs

Serial Communications

MoDBuS RTu

SDX

DF1

SMS

Industrial Control Links, Inc.

Applications:

MIRRoRED I/o To ELIMINATE CoNDuIT AND CoPPER WIRING

ETHERNET AND WIRELESS DISTRIBuTED I/o EXPANSIoN

DATA RECoRDING FoR PRoDuCTIoN TRACKING AND CoMPLIANCE MoNIToRING

CELLuLAR ALARMING FoR LIFT STATIoNS AND PRoCESS CoNTRoLS

WIRELESS PuMP CoNTRoL WITHouT CoSTLY PLCs AND PRoGRAMMING

ENERGY MoNIToRING AND LoAD SHEDDING

Solaras II and Spectra RTUs have built-in solar controllers/UPSs. Save $$$ by simply adding a solar panel or power supply, and a battery.

SOLAR

Security

Latest security technologies to protect your systems and data exchanges.

SECuRE EMBEDDED oS

CoMMuNICATIoNS ENCRYPTIoN

SECuRE uSER ACCESS MANAGER

HMIs

Replace or supplement expensive PC HMI software. HMIs are built in and easier to use, with no recurring license fees, user limits, tag limits or maintenance fees.

CoNFIGuRABLE uSER WEB PAGES

TEXT MESSAGE HMI INTERFACE oVER CELLuLAR

BuILT-IN SuPPoRT FoR VIEWPoINT HMI PANELS

Control

Powerful pre-built control functions—simply fill in the blanks for configuration.

FuLL DuPLEX PuMP CoNTRoLLER

DuAL LooP PID CoNTRoLLER (SPRITE II)

8 SETPoINT CoNTRoL BLoCKS

ENERGY CALCuLATIoN BLoCKS

Page 3: Sentry Series Remote Telemetry Units - iclinks.com sales... · 2014-12-19 · Sentry Series RTUs Features & Benefits Smart & Economical Connectivity Easily connect to nearly any SCADA

Description

Eth

erne

t

uP

S/S

olar

Con

trol

ler

I/O Internal Options*External Options

Terminal Diagrams Wiring Diagram Examples Dimensions

uni

vers

al In

puts

Ana

log

Inpu

ts

Ana

log

out

puts

Dig

ital I

nput

s

Dig

ital o

utpu

ts

Dig

ital I

/o

RS

-232

/RS

-485

Ser

ial P

ort

Mic

roha

rd R

adio

Free

wav

e R

adio

Dig

i/Max

stre

am R

adio

Cel

lula

r M

odem

Leas

ed L

ine

Mod

em

Eth

erne

t Rad

ios

VH

F/u

HF

Rad

io

Sprite II Sprite II is a general purpose I/o module with a symmetrical I/o mix: 2 universal analog inputs and 2 analog outputs, 4 digital inputs and 4 relay outputs. Sprite II is ideal for “mirrored” I/o, pump control, and lift stations. Includes closed-loop PID Control.

1 2 2 4 4 • • • • • • • •

Solaras II Solaras II is designed from the ground up as a solar-powered or battery backed RTu. Just add a battery and a solar panel or DC power source; no external solar controller or uPS required! Solaras II is the ideal solution for tank, stream and reservoir monitoring and alarming.

1 SOLAR 2 8 • • • • • • • •

Spectra Spectra is also designed from the ground up as a solar-powered or battery backed RTu. Just add a battery and a solar panel or DC power source; no external solar controller or uPS required! Spectra has the most analog inputs especially for energy usage, as well as compliance and regulatory monitoring.

1 SOLAR 4 2** 2 • • • • • • • •

Stratus Stratus has many analog outputs and digital I/o, making it ideal as one end of a “mirrored” I/o system. Take readings from the field and re-drive loop displays, chart recorders or PLCs with secure communications.

1 6 6 • • • • • • • •

Spirit Spirit has isolated high performance analog inputs where non ground referenced signals must be measured. Besides reading voltage, mV, thermocouples and current loops, Spirit can read ripple voltage and mV; ideal for monitoring cathodic protection systems.

1 8*** 2 • • • • • • • •

* Can have 1 serial port option plus 1 internal radio option. ** 20mA *** 4 pairs of analog inputs, one V, mV, and TC input, and one current input, per pair.

Sentry Series Selection Guide

Page 4: Sentry Series Remote Telemetry Units - iclinks.com sales... · 2014-12-19 · Sentry Series RTUs Features & Benefits Smart & Economical Connectivity Easily connect to nearly any SCADA

Description

Eth

erne

t

uP

S/S

olar

Con

trol

ler

I/O Internal Options*External Options

Terminal Diagrams Wiring Diagram Examples Dimensions

uni

vers

al In

puts

Ana

log

Inpu

ts

Ana

log

out

puts

Dig

ital I

nput

s

Dig

ital o

utpu

ts

Dig

ital I

/o

RS

-232

/RS

-485

Ser

ial P

ort

Mic

roha

rd R

adio

Free

wav

e R

adio

Dig

i/Max

stre

am R

adio

Cel

lula

r M

odem

Leas

ed L

ine

Mod

em

Eth

erne

t Rad

ios

VH

F/u

HF

Rad

io

Sprite II Sprite II is a general purpose I/o module with a symmetrical I/o mix: 2 universal analog inputs and 2 analog outputs, 4 digital inputs and 4 relay outputs. Sprite II is ideal for “mirrored” I/o, pump control, and lift stations. Includes closed-loop PID Control.

1 2 2 4 4 • • • • • • • •

+Pow

er In

Grou

nd+2

4V L

op P

ower

Out

Univ

ersa

l (An

alog

) Inp

ut 1

Univ

ersa

l (An

alog

) Inp

ut 2

Anal

og O

utpu

t 1An

alog

Out

put 2

Grou

ndDi

gita

l Inp

ut/O

utpu

t 1Di

gita

l Inp

ut/O

utpu

t 2Di

gita

l Inp

ut/O

utpu

t 3Di

gita

l Inp

ut/O

utpu

t 4Re

lay

Outp

ut 1

Rela

y Ou

tput

2Re

lay

Outp

ut 3

Rela

y Ou

tput

4Re

lay

Outp

ut C

omm

on

20m

A

24Vd

cPo

wer

20m

A20

mA

20m

A

5V

+ +++ +

+

+- +-

1.41.4˝̋

3.73.7˝̋

3.73.7˝̋

0.60.6˝̋

3.13.1˝̋

Solaras II Solaras II is designed from the ground up as a solar-powered or battery backed RTu. Just add a battery and a solar panel or DC power source; no external solar controller or uPS required! Solaras II is the ideal solution for tank, stream and reservoir monitoring and alarming.

1 2 8 • • • • • • • •

+Pow

er In

Grou

nd+1

2V B

atte

ry+P

ower

Out

+24V

Loo

p Po

wer

Out

Univ

ersa

l (An

alog

) Inp

ut 1

Univ

ersa

l (An

alog

) Inp

ut 2

Grou

ndDi

gita

l Inp

ut/O

utpu

t 1Di

gita

l Inp

ut/O

utpu

t 2Di

gita

l Inp

ut/O

utpu

t 3Di

gita

l Inp

ut/O

utpu

t 4Di

gita

l Inp

ut/O

utpu

t 5Di

gita

l Inp

ut/O

utpu

t 6Di

gita

l Inp

ut/O

utpu

t 7Di

gita

l Inp

ut/O

utpu

t 8Gr

ound

+V GND

+BAT

+VA

UI1

UI2

GND

DIO1

DIO2

DIO3

DIO4

DIO5

DIO6

DIO7

DIO8

GND

+VO

20m

A+ +

20m

A

5V

+V GND

+BAT

+VA

UI1

UI2

GND

DIO1

DIO2

DIO3

DIO4

DIO5

DIO6

DIO7

DIO8

GND

+VO

Sola

rPa

nel

+ +

+- +-

+

Spectra Spectra is also designed from the ground up as a solar-powered or battery backed RTu. Just add a battery and a solar panel or DC power source; no external solar controller or uPS required! Spectra has the most analog inputs especially for energy usage, as well as compliance and regulatory monitoring.

1 4 2** 2 • • • • • • • •

+Pow

er In

Grou

nd+1

2V B

atte

ry+P

ower

Out

+24V

Loo

p Po

wer

Out

Univ

ersa

l (An

alog

) Inp

ut 1

Univ

ersa

l (An

alog

) Inp

ut 2

Grou

ndUn

iver

sal (

Anal

og) I

nput

3Un

iver

sal (

Anal

og) I

nput

4Gr

ound

Anal

og In

put 5

Anal

ig In

put 6

Grou

ndDi

gita

l Inp

ut/O

utpu

t 1Di

gita

l Inp

ut/O

utpu

t 2Gr

ound

Sola

rPa

nel

+

+

+-

20m

A+

20m

A+

20m

A+

20m

A+

+-

Stratus Stratus has many analog outputs and digital I/o, making it ideal as one end of a “mirrored” I/o system. Take readings from the field and re-drive loop displays, chart recorders or PLCs with secure communications.

1 6 6 • • • • • • • •

+Pow

er In

Grou

ndAn

alog

Out

put 1

Anal

og O

utpu

t 2An

alog

Out

put 3

Grou

ndAn

alog

Out

put 4

Anal

og O

utpu

t 5An

alog

Out

put 6

Grou

ndDi

gita

l Inp

ut/O

utpu

t 1Di

gita

l Inp

ut/O

utpu

t 2Di

gita

l Inp

ut/O

utpu

t 3Gr

ound

Digi

tal I

nput

/Out

put 4

Digi

tal I

nput

/Out

put 5

Digi

tal I

nput

/Out

put 6

24Vd

cPo

wer

+

20m

A+

20m

A+

20m

A+

20m

A+

20m

A+

20m

A+

5V

+

+

-

+-

Spirit Spirit has isolated high performance analog inputs where non ground referenced signals must be measured. Besides reading voltage, mV, thermocouples and current loops, Spirit can read ripple voltage and mV; ideal for monitoring cathodic protection systems.

1 8*** 2 • • • • • • • •

+Pow

er In

Grou

ndAI

-1 V

/mV

AI-2

Cur

rent

Com

mon

AI-1

/2AI

-3 V

/mV

AI-4

Cur

rent

Com

mon

AI-3

/4AI

-5 V

/mV

AI-6

Cur

rent

Com

mon

AI-5

/6AI

-7 V

/mV

AI-8

Cur

rent

Com

mon

AI-7

/8Di

gita

l Inp

ut/O

utpu

t 1Di

gita

l Inp

ut/O

utpu

t 2Gr

ound

24Vd

cPo

wer

+

5V+

20m

A+

20m

A+

20m

A+

1V+

20m

A+

+- +-

* Can have 1 serial port option plus 1 internal radio option. ** 20mA *** 4 pairs of analog inputs, one V, mV, and TC input, and one current input, per pair.

Page 5: Sentry Series Remote Telemetry Units - iclinks.com sales... · 2014-12-19 · Sentry Series RTUs Features & Benefits Smart & Economical Connectivity Easily connect to nearly any SCADA

Sentry Series—Common Features

Storage 32MB Internal Flash Disk (64MB and Larger optional)

Universal Inputs 16-bit Analog Inputs with Sensor Conditoning and Configurable Filtering, up to 800 Samples/Second

20mA, 0 to 2V, 0 to 5V, 100 mV, 250 mV, +/-250 mV, 30K and 300K ohms, Thermocouple

(Type J, K, T, E, R, S, B, N), Thermistor (10K, Type II & Type III), RTD 2 and 3-wire (10,100, 1K ohm)

note: 3-wire RTDs Require 2 Inputs Each

Analog Inputs 0/4 to 20mA, 1mA oR 0 to 5V, 100 mV, 250 mV, +/-250 mV, Thermocouple (Type J, K, T, E, R, S, B, N)

Depending on Model

Analog Outputs 16-Bit, 0/4 to 20mA

Digital Inputs Contact Closure, or 0 to 30Vdc Inputs, Configurable Filtering, Counting to 10kHz

Digital I/O Contact Closure, or 0 to 30Vdc Inputs, 0 to 30Vdc 1A Protected FET outputs, Configurable Filtering,

Counting to 10kHz

Digital Outputs (Sprite) Relay Contacts up to 120V, up to 3A

Solar Controller/UPS (Solaras and Spectra only) up to 3A Battery Backed Power to External Equipment in Addition to Controller.

Requires External 12V Lead-acid Gel-Cel Battery, 3 to 18 AH, 0.8A Charge Current Max.

Warranty 3 Years, Factory Parts and Labor

Operating Range -40˚F (-40˚C) to 158˚F (70˚C), 5%RH to 95%RH, Non-Condensing

Safety Certified for use in Hazardous Locations—Class 1, Div 2, Groups A, B, C, D (uL/CSA)

Power 10 to 28Vdc Power Draw Depends on I/o & option Configuration—Contact Factory

Mounting 35mm DIN Rail

Internal Options

Serial Port RS-232 and RS-485, Baud Rate adjustable from 1200 to 115200

Wireless Options 902MHz to 928MHz Spread Spectrum, Frequency Hopping, 1Watt, 115K Baud

Digi/Maxstream Sensitivity: -110dBm @9600 Baud, -100dBm @115K Baud, Point to Multipoint & Peer to Peer, DigiMesh

Microhard Sensitivity: -108dBm (BER 10-6), 32-bit CRC, Point to Multipoint, Network Diagnostics

Freewave Sensitivity: -108dBm (BER 10-6), 32-bit CRC, Point to Multipoint, Network Diagnostics, FGR-115 Compatible

Cellular GSM/GPRS/HSPA (AT&T, T-Mobile, Rogers, Telus), Quad Band 850/900/1800/1900 MHz

CDMA/EV-Do (Verizon, Sprint), Dual Band 800/190 MHz

External Options (Requires Serial Port option—Except for Ethernet Radios)

Leased Line Input: -40dB to +6d8, Automatic Gain Adjust

output: 600 ohms, -40dB to +6dB, user Settable

VHF/MURS Radio 150MHz to 174MHz, 5W (VHF), 2W (MuRS),

Sensitivity: -118dBm@1200bps, -114dBm @ 4800bps, -108 dBM @ 9600bps

UHF Radio 450MHz to 480MHz, 5W (uHF),

Sensitivity: -116 dBm@4800bps, -108dBm @ 9600bps

Ethernet Radios 900MHz, up to 1.2 Mbps, 1W, up to -108dBm Sensitivity

2.4GHz, 5.8 GHz, up to 54 Mbps, 1W, up to -97dBm Sensitivity

Page 6: Sentry Series Remote Telemetry Units - iclinks.com sales... · 2014-12-19 · Sentry Series RTUs Features & Benefits Smart & Economical Connectivity Easily connect to nearly any SCADA

Industrial Control Links, Inc.

12840 Earhart Avenue Auburn, CA 95602 uSA

Phone: 530.888.1800Fax: 530.888.7017E-mail: [email protected]

www.iclinks.com

For Additional Product Information Visit www.iclinks.com

Industrial Control Links, Inc.