Page 1: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

Product Data SheetPS-00292-EUJanuary 2001

Series 3000 Coriolis Transmittersand Discrete Controllers

Page 2: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

2 Series 3000 Transmitters and Discrete Controllers

Series 3000 transmitters and discrete controllers

��������������������������������

PLC

DCS

Process Indicator

Investment

Cap

abili

ty

Series3000

Series3000

Pointof

Process

TemperatureConcentration

Den

sity

Micro Motion® Series 3000 electronics combineCoriolis transmitter functions and PLC capabilities inone instrument. Four models of Series 3000transmitter/controllers feature different combinations offunctionality to suit a wide variety of process controlapplications.

Series 3000 transmitter/controllers provide discreteprocess control for batch applications, advanceddensity analyses, net oil measurement, custodytransfer security, and more. Transmitter functionalityincludes highly accurate Coriolis flow, density, andtemperature measurement — in a single device. Withall this performance, Series 3000 transmitter/controllers deliver significant increases in capability ata cost-effective price.

For applications that require only simple valve closuresor alarms, select a model with discrete controlfunctions only. When also measuring and displayingprocess parameters, choose a discrete controller withan integrated transmitter. When your needs change,adding transmitter functionality to a controller youalready own is easy.

Because Series 3000 transmitter/controllers combinethe functionality of several instruments, you candecrease your plant's labor, maintenance, andoperating costs while increasing efficiency,accelerating throughput, and improving product quality.

In many cases, an application that might otherwiserequire density meters, temperature detectors,refractometers, or other peripheral instruments can besimplified with a single device — a Series 3000transmitter/controller. Series 3000 electronics take careof all your measurement needs, automatically, and withno maintenance. Manual calculations, estimations, andadditional laboratory testing are no longer necessary.

Micro Motion works closely with a number ofinternational standards organizations to providesolutions for many common processes. Processcurves, such as the one below, are developed byMicro Motion and entered into Series 3000 memory,either at the Micro Motion factory or at your site. TheSeries 3000 open architecture allows you to enter yourown proprietary process curve data, easily andaccurately.

Micro Motion has developed process curve data formany proprietary fluids. You benefit throughMicro Motion’s comprehensive understanding of theprocess variables that affect the accuracy of thesemeasurements.

Page 3: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

Series 3000 Transmitters and Discrete Controllers 3

POINT-OF-PROCESS CONTROLSeries 3000 transmitter/controllers allow you toefficiently and effectively optimize your unique processcontrol needs. Series 3000 electronics are the perfectsolution for point-of-process applications that requireaccurate process indication and focused PLCcapabilities.

Configuration, operation, and maintenance are allaccomplished using the innovative Series 3000user interface. The interface features an easy to use,oversized, backlit display with large, tactile-feedbackpushbuttons. Other user interfaces, such as hand-heldcommunication devices, are not required.

Each Series 3000 device can simultaneously supportup to three applications, and functionality can be addedto support your changing requirements. TheSeries 3000 architecture was designed to be flexiblefor easy field upgrades. Series 3000 electronicsinclude the ability to upload new software for additionalor future applications, and the capacity to accept newhardware as it becomes available.

Process monitor and totalizerAll Micro Motion Series 3000 discrete controllers andtransmitter/controllers provide process monitoring formultiple variables, including Coriolis mass flow, volumeflow, density, and temperature. Process monitoring andtransmitter totalizer control is built into the electronics.

Discrete batch controlDiscrete batch control is easy with Micro MotionSeries 3000 discrete controllers and transmitter/controllers. Batch control includes these functions:

• Configuration of up to six preset batch recipes

• One-stage or two-stage batch control

• End-of-batch warning and batch-overrun alarms

• Configuration by quantity or by percent of target forprimary valve closure, secondary valve openingand closure, end warning, and batch overrun

• Configuration for target lockout, or for targetadjustment during batch operation

Discrete batch control provides one more uniquefeature, automatic overshoot compensation. AOCmonitors and automatically adjusts flow rate to accountfor valve closure time, reducing setup time andmaintenance costs.

Enhanced densitySeries 3000 electronics are unique in their ability toprovide enhanced density solutions for a number ofapplications, including:

• %HFCS, °Brix, °Plato, °Balling; °Baumé atSG60/60

• Density at reference temperature

• Specific gravity

• Concentration derived from reference density

• Concentration derived from specific gravity

Net oilThe Series 3000 Net Oil Computer is the perfectanswer for your crude oil applications. The Series 3000NOC provides:

• Well-performance measurement

• Group production, continuous measurement

• Oil and water density determination

• Transient bubble remediation (TBR)

• Backflow totalizers and compensation

Page 4: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

4 Series 3000 Transmitters and Discrete Controllers

Series 3000 transmitters and discrete controllers continued

DESIGNED TO FIT YOUR NEEDSFour models of Series 3000 electronics, plus anoptional relays accessory, provide variouscombinations of functionality to fit your applicationneeds. Features are compared on the opposite page.

Each Series 3000 device can run up to threeapplications simultaneously. New hardware andsoftware functionality can be added as it becomesavailable.

Model 3300 discrete controllerThe Model 3300 discrete controller providesmeasurement and control functions based on inputfrom external devices.

Model 3350 field-mount discrete controllerThe Model 3350 discrete controller features the samefunctionality as the Model 3300, in a field-mountenclosure that meets area classifications worldwide.

Model 3500 transmitter/controllerThe Model 3500 discrete controller with integratedtransmitter uses Micro Motion Coriolis technology forflow and density measurement to provide applicationsolutions capabilities.

Model 3700 field-mount transmitter/controllerThe Model 3700 discrete controller with integratedtransmitter features the same functionality as theModel 3500, in a field-mount enclosure that meets areaclassifications worldwide.

Model 3100 accessoryThe Model 3100 accessory features relay packs forinterfacing with high-energy solenoids, pump starters,and other devices.

Page 5: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

Series 3000 Transmitters and Discrete Controllers 5

Housing options

Rack-mount

Panel-mount

Field-mount IP67 (NEMA 4X)

Interface/display

Backlit LCD and keypad

Large, tactile feedback buttons

Electrical connections

Input and output connections

Type D connectors

Solder tails

Screw terminals

I/O cable, remote screw terminals

Internal wiring compartments

Power connection

Screw terminals

Power supply options

85 to 265 VAC

18 to 30 VDC

Input signals

One frequency/pulse input

Two discrete, momentary inputs

One intrinsically safe, 9-wireCoriolis sensor signal input

Output signals

One frequency/pulse output

Two active 4-20 mA outputs

Three discrete outputs

Printer port

One RS-485 port (requiresRS-232 adaptor)

Model 3300

u

u

u

u

u

u

u

u

u

u

u

u

u

Model 3350

u

u

u

u

u

u

u

u

u

u

u

u

u

u

Model 3500

u

u

u

u

u

u

u

u

u

u

u

u

u

u

Model 3700

u

u

u

u

u

u

u

u

u

u

u

u

u

u

u

Series 3000 features comparison

� Rack-mount version only.

� Standard on panel-mount version, optional on rack-mount version.

� Panel-mount version only.

Page 6: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

6 Series 3000 Transmitters and Discrete Controllers

Series 3000 functional specifications

HousingsRack-mount

486,2 mm rack-mount housing meets DIN standard 41494and IEC 297-3

Front panel is rated IP40

Panel-mountWith bezel mounting kit, fits into same cutout as

Micro Motion peripherals. Series 3000 bezel is largerthan bezel on Micro Motion DRT, FMS-3, DMS, NFC, orNOC; dimensions provided on page 11

Front panel with bezel is rated NEMA IP65 (NEMA 4X)

Field-mountCompartment with threaded cover contains electronics

Terminal compartment contains non-intrinsically safecompartment with input and output terminals; andintrinsically safe compartment with interface/display,sensor terminals (Model 3700 only), and optional inputand output terminals

Mounting bracket and interface/display rotate to allowmounting in four different orientations

Rated IP67 (NEMA 4X)

Interface/displayDisplay

Models 3300 and 3500Backlit LCD, 128x128 pixel, bit mapAdjustable contrastNon-glare, chemical-resistant acrylic lens

Models 3350 and 3700Backlit LCD, 128x128 pixel, bit mapAdjustable contrastNon-glare tempered glass lensSuitable for hazardous area installation

Keypad membrane switchLarge pushbuttons with tactile feedbackSoftware-defined function keysChemical-resistant polyester

WeightModels 3300 and 3500

Maximum 1,6 kg, excluding prepared cables

Models 3350 and 37008,6 kg

Electrical connectionsInput and output connections

Rack-mountType D connectors per DIN standard 41612 (IEC 603-2)Available as solder tails (standard) or screw terminals

(optional)Screw terminals accept 0,25 mm2 to 1,5 mm2 wires

Panel-mountScrew terminals (standard) or I/O cable with remote DIN

rail-mount screw terminals (optional)Remote terminals attach to any of four rail types. I/O cable

is available in lengths of 0,6;1,5 and 3 metersTerminals accept 0,25 mm2 to 1,5 mm2 wires

Field-mountTwo color-coded wiring compartments

Compartment with intrinsically safe terminals hastwo 3/4-inch NPT or M20x1,5 conduit openings

Compartment with non-intrinsically-safe terminals hasthree 3/4-inch NPT or M20x1,5 conduit openings

Screw terminals accept 0,34 mm2 to 1,5 mm2 wires

Power connectionRack-mountScrew terminals are fixed to rack chassisGround makes first and breaks lastTerminals accept 0,75 mm2 to 2,5 mm2 wires

Panel-mountScrew terminals accept 0,75 mm2 to 2,5 mm2 wires

Field-mountScrew terminals accept 0,75 mm2 to 4,0 mm2 wires

Input signalsNon-intrinsically-safe input signals

One 2-wire frequency/pulse inputFrequency range 0-20000 HzMinimum pulse width 25 µ-secPower sourcing or sinkingVoltage 0-0,8 VDC low state

3-30 VDC high stateCurrent nominal 5 mA pull-up

Two discrete, momentary inputsPulse width 0,15 µ-sec minimumVoltage 0-0,8 VDC low state

3-30 VDC high statedry contacts

Intrinsically safe input signalsOne 9-wire Coriolis sensor signal input with ground

Page 7: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

Series 3000 Transmitters and Discrete Controllers 7

Output signalsNon-intrinsically-safe output signals

Two active 4-20 mA outputsIsolated to ± 50 VDC from all other outputs and earth

groundMaximum load limit, 1000 ohmsOutput is linear with process from 3,8 to 20,5 mA, per

NAMUR NE43 (June 1994)

Three discrete outputsConfigurable for the applicationPower

Active or passive, software selectableVoltage

24 VDC nominalCurrent

Sourcing at 5,6 mA when Vout = 3 VDCSinking up to 500 mA at 30 VDC maximum

One 2-wire frequency/pulse outputConfigurable for rate control or totalizationScalable to 10000 HzOutput is linear with flow rate to 12500 HzPulse width

50% duty cycle above 500 HzConfigurable for frequencies below 500 Hz

PowerActive or passive, software selectable

Voltage24 VDC nominal, active20 VDC applied maximum, passive

CurrentSourcing 10 mA at 3 VDC, activeSinking 500 mA, active or passive

Fault outputWhen a fault is detected, outputs go to configured states.User can select high, low, last measured value, or internalzero. Milliampere outputs conform to NAMUR NE43 (June1994).

High output limits can be configured from 21 to 24 mAfor milliampere; 15000 Hz for frequency

Low output limits can be configured from 1 to 3,6 mA formilliampere; 0 Hz for frequency

Last measured value is the last output for the processvariable

Internal zero drives the milliampere and frequencyoutputs for process variables to zero values

Printer portOne RS-485 port (standard)

Requires external adaptor (not included) for conversion toRS-232 signal

Send only

Power supplyAC power supply

Model 330085 to 265 VAC50/60 Hz, 15 VA0,25 A maximum at 85 VAC, 0,12 A maximum at 265 VACIEC 127-3/4 fuse, 0,63 A time-delayComplies with low-voltage directive 73/23/EEC per IEC

1010-1 with Amendment 2Installation (Overvoltage) Category II, Pollution Degree 2

Models 3350, 3500 and 370085 to 265 VAC50/60 Hz, 30 VA0,33 A maximum at 85 VAC, 0,15 A maximum at 265 VACIEC 127-3/4 fuse, 0,63 A time-delayComplies with low-voltage directive 73/23/EEC per IEC

1010-1 with Amendment 2Installation (Overvoltage) Category II, Pollution Degree 2

DC power supplyModel 330018 to 30 VDC7 watts typical, 14 watts maximumIEC 127-3/4 fuse, 1,6 A time-delay

Models 3350, 3500 and 370018 to 30 VDC18 watts typical, 25 watts maximumIEC 127-3/4 fuse, 1,6 A time-delay

Environmental limitsAmbient temperature limits

Operating –20 to 60°CStorage –40 to 70°C

Some darkening of display might occur above 55°CDisplay responsiveness decreases below –20°C

Humidity limits5 to 95% relative humidity, non-condensing at 60°C

Vibration limitsPer IEC 68-2-6 at 1,0 g over 15 to 2000 Hz, 50 sweep

cycles

Environmental effectsEMI effects

All Series 3000 devices conform to NAMUR NE21(June 1997)

Models 3300 and 3350Meets EMC directive 89/336/EEC per EN 50081-2(August 1993) and EN 50082-2 (March 1995)

Models 3500 and 3700Meets EMC directive 89/336/EEC per EN 61326 Industrial

Ambient temperature effectOn analog outputs ± 0,005% of span per °C

Page 8: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

8 Series 3000 Transmitters and Discrete Controllers

Hazardous area classificationsUL and CSA

Contact Micro Motion for UL Division 2 entity parameters

Model 3300Class I, Div. 2, Groups A, B, C, D when installed in asuitable enclosure.

Model 3350Class I, Div. 2, Groups A, B, C, and D (standard housing).

Model 3500Class I, Div. 2, Groups A, B, C, D when installed in asuitable enclosure. Provides non-incendive sensoroutputs for use in Class I, Div. 2, Groups A, B, C, D, orintrinsically safe sensor outputs for use in Class I, Div. 1,Groups C and D; Class II, Div. 1, Groups E, F, and G.

Model 3700Class I, Div. 2, Groups A, B, C, and D (standard housing).Provides non-incendive sensor outputs for use in Class I,Div. 2, Groups A, B, C, D, or intrinsically safe sensoroutputs for use in Class I, Div. 1, Groups C and D;Class II, Div. 1, Groups E, F, and G.

CENELECModel 3300CENELEC Zone 2 when properly installed in a suitableenclosure. Zone 2 certificate per prEN 50 021 (1996).

Model 3350CENELEC Zone 1 EEx de [ib] IIB/C T4

Model 3500Safe area only, when properly installed in a suitableenclosure. Can be connected to sensor in CENELEC[EEx ib] IIB/C area.

Model 3700CENELEC Zone 1 EEx de [ib] IIB/C T4

Model 3100 accessoryRelay packs

Three relaysSolid state, SPSTRated at 24–250 VAC, 40 mA to 5 A; or 0–70 VDC, 5 AEnergized by discrete outputsIP65(NEMA 4X) enclosure (optional)

UL and CSA approvalsClass I, Div. 2, Groups A, B, C, and D

CENELEC approvalsSuitable for installation in Zone 2, complying withATEX Directive (94/9/EC) for Group II, Category 3G,according to CENELEC standard prEN 50021:1998 andmarked as:

EEx n V II T4KEMA 97 ATEX4940XAmbient temperature –20 to 60°C

Additional, installation-specific requirements aredescribed in detail in the instructions that are shipped withthe Model 3100 accessory.

Series 3000 functional specifications continued

Page 9: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

Series 3000 Transmitters and Discrete Controllers 9

Model 3500/3700 performance specifications

Sensor model Flow accuracy *

ELITE® liquid ± 0,10% ± [(zero stability/flow rate) x 100]% of rategas ± 0,50% ± [(zero stability/flow rate) x 100]% of rate

T-Series liquid only ± 0,15% ± [(zero stability/flow rate) x 100]% of rate

F-Series liquid ± 0,20% ± [(zero stability/flow rate) x 100]% of rategas ± 0,70% ± [(zero stability/flow rate) x 100]% of rate

D (except DH38), DL and DT liquid ± 0,15% ± [(zero stability/flow rate) x 100]% of rategas ± 0,65% ± [(zero stability/flow rate) x 100]% of rate

DH38 liquid ± 0,15% ± [(zero stability/flow rate) x 100]% of rategas ± 0,50% ± [(zero stability/flow rate) x 100]% of rate

Sensor model Flow repeatability *

ELITE liquid ± 0,05% ± [½(zero stability/flow rate) x 100]% of rategas ± 0,25% ± [(zero stability/flow rate) x 100]% of rate

T-Series liquid only ± 0,05% ± [½(zero stability/flow rate) x 100]% of rate

F-Series liquid ± 0,10% ± [½(zero stability/flow rate) x 100]% of rategas ± 0,35% ± [(zero stability/flow rate) x 100]% of rate

D (except DH38), DL and DT liquid ± 0,05% ± [½(zero stability/flow rate) x 100]% of rategas ± 0,30% ± [(zero stability/flow rate) x 100]% of rate

DH38 liquid ± 0,05% ± [½(zero stability/flow rate) x 100]% of rategas ± 0,25% ± [½(zero stability/flow rate) x 100]% of rate

Sensor model Density accuracy Density repeatability

ELITE (except high-pressure CMF010P) liquid ± 0,5 kg/m3 ± 0,2 kg/m3

gas ± 2,0 kg/m3 ± 1,0 kg/m3

ELITE high-pressure CMF010P liquid ± 2,0 kg/m3 ± 1,0 kg/m3

gas ± 8,0 kg/m3 ± 4,0 kg/m3

T-Series liquid only ± 2,0 kg/m3 ± 0,5 kg/m3

F-Series liquid only ± 2,0 kg/m3 ± 1,0 kg/m3

D6, D12, D25, D40, liquid only ± 2,0 kg/m3 ± 1,0 kg/m3

DH100, DH150

DH6, DH12, DH25, DH38 liquid only ± 4,0 kg/m3 ± 2,0 kg/m3

D65, DL65, DT65, liquid only ± 1,0 kg/m3 ± 0,5 kg/m3

D100, DT100, D150, DT150,DH300

DL100, DL200 liquid only ± 0,5 kg/m3 ± 0,2 kg/m3

D300, D600

Sensor model Temperature accuracy Temperature repeatability

All models ± 1°C ± 0,5% of reading in °C ± 0,2°C

* Flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. All specifications are based on reference conditions of water at20 to 25°C, and 1 to 2 bar unless otherwise noted. For values of zero stability, refer to product specifications for each sensor.

Page 10: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

10 Series 3000 Transmitters and Discrete Controllers

Dimensions in mm

Rack-mount

Model 3300/3500 physical specifications

3HE

25 TE 127

128,5

28 TE 142,2

122,5

4x M2,5 - 11

19” - 486 mm subrack conforms toDIN 41494, Part 5 and IEC 297-3Not included as part of Model 3300/3500

27 TE2 x coding pins

4 TE* 16 TE* 25 TE*

*Distance from neighboring unit or from edge of subrack.

Front View

19” - 486 mm subrack conforms toDIN 41494, Part 5 and IEC 297-3Not included as part of Model 3300/3500

4 x M2,5 - 8 (Model 3300)6 x M2,5 - 8 (Model 3500)

Back View

Power-supplyterminals

Standard solder terminals shownScrew terminals optional

Sensor and intrinsicallysafe I/O terminals(Model 3500 only)

Non-intrinsicallysafe I/O terminals

25,4 169,9

186,7

200,6

216,2

Intrinsic safety barrier(Model 3500 only)

Screw-terminal connector(optional)

Rear rail for mountingconnectors conforming toDIN 41612 and ICE 603-2

Page 11: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

Series 3000 Transmitters and Discrete Controllers 11

Dimensions in mm

Panel-mount with optional I/O cable

Panel-mount with standard screw terminals

Model 3300/3500 physical specifications continued

Bezel

152

152

214

200Frame

114

170

Intrinsic safety barrier(Model 3500 only)

12

Mounting surfaceCutout: 138 square

Power-supplycable

165

Intrinsically safesensor and I/O terminals(Model 3500 only)

Non-intrinsically safeI/O terminals

152

152

Bezel Frame

Intrinsic safety barrier(Model 3500 only)

Mounting surfaceCutout: 138 square

Intrinsically safesensor and I/O cable(Model 3500 only)

Non-intrinsicallysafe I/O cable

Power-supplycable

222

135

170

12

165

Minimumradius 100 To DIN-rail-mount

terminals

DIN-rail-mountscrew terminals detail

57

90

66

77

229

DIN rail

Page 12: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

12 Series 3000 Transmitters and Discrete Controllers

Dimensions in mm

Model 3350/3700 physical specifications

305

2794 x 9

102 71

92

152

102

234

Display cover can berotated 90 degrees

228

156

221

394

129 minimum clearance forremoval of circuit boards

2 x 71

2 x 24

264

190

146

Case ground

Mounting brackets can berotated 90 degrees4 x M 8 - 16 bolts are includedto Model 3350 or 3700

5 x 3/4-14 NPT female orM 20 x 1,5 conduit openings

48

Page 13: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

Series 3000 Transmitters and Discrete Controllers 13

IP65 (NEMA 4X) enclosure physical specificationsDimensions in mm

86165

314

159

210 286

314

273

152 4 x Ø 8

IP65 (NEMA 4X) enclosure for Model 3100 relays only

Page 14: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

14 Series 3000 Transmitters and Discrete Controllers

Series 3000 model number overview

Step 1. Specify a product model number and application code

Example:

Product model number 3500R1A03A1UEDBZ Model 3500 rack-mount, 85 to 265 VACpower-supply, standard 9-wire sensor interface,solder-pin connectors, UL approval,English-language display and instructions, discretebatch control and enhanced density software withpredefined algorithms for food & beverageapplications

See pages 15-18

Step 2. Optional: For languages other than English, French, or German, specify a language code forquick-reference installation instructions

Example:

Language code QREF3000RS Additional Model 3300/3500 rack-mountquick-reference guide in Spanish

See page 19

Step 3. Optional: Specify desired accessories (optional)

Example:

Accessory code 3100A1AUE Optional Model 3100 high-energy relays, 24 to 250 VACpower supply, UL approval, English instructions

See page 19

Page 15: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

Series 3000 Transmitters and Discrete Controllers 15

Code Discrete controller model

3300 Model 3300 discrete controller

Code Mounting options

R Rack mountP Panel mount

Code Power-supply options

1 85 to 265 VAC2 18 to 30 VDC

Code Communication gateway module

A None

Code Additional hardware module

0 None1 USA - W&M custody transfer — does not meet OIML requirements

Code Sensor interface

0 None

Code Terminals

A Solder pins — mounting code R onlyB Screw terminalsC I/O cables, 0,6 meters long — mounting code P onlyD I/O cables, 1,3 meters long — mounting code P onlyE I/O cables, 2,5 meters long — mounting code P only

Code Optional relays and housings

1 None

Code Approvals

M Micro Motion standard (no approvals)U UL Class I, Div. 2, Groups A–D, with non-incendive outputsB CENELEC Zone 2

Code Language

E EnglishB English for Brazil or ArgentinaF FrenchG German

Code Application software

ZZZ Process monitor/totalizer (standard) — not available with hardware module code 1DZZ Discrete batch controller

Example:

3300 R 1 A 0 0 A 1 U E ZZZ

Model 3300 product matrix

Page 16: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

16 Series 3000 Transmitters and Discrete Controllers

Code Discrete controller model

3350 Model 3350 field-mount discrete controller

Code Mounting options

A Standard

Code Power-supply options

1 85 to 265 VAC2 18 to 30 VDC

Code Communication gateway module

A None

Code Additional hardware module

0 None1 USA - W&M custody transfer — does not meet OIML requirements

Code Sensor interface

0 None

Code Conduit connections

A M20 without conduit glandsB M20 with three increased-safety conduit glandsC M20 with five increased-safety conduit glandsD 3/4-inch NPT without conduit seals

Code Approvals

M Micro Motion standard (no approvals)U UL Class I, Div. 2, Groups A–D, with non-incendive outputsZ CENELEC Zone 1

Code Language

E EnglishB English for Brazil or ArgentinaF FrenchG German

Code Application software

ZZZ Process monitor/totalizer (standard) — not available with hardware module code 1DZZ Discrete batch controller

Example:

3350 A 1 A 0 0 A U E DZZ

Model 3350 number matrix

Page 17: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

Series 3000 Transmitters and Discrete Controllers 17

Code Transmitter/controller model

3500 Model 3500 discrete controller with integrated Coriolis transmitter

Code Mounting options

R Rack mountP Panel mount

Code Power-supply options

1 85 to 265 VAC2 18 to 30 VDC

Code Communication gateway module

A None

Code Additional hardware module

0 None1 USA - W&M custody transfer — does not meet OIML requirements

Code Sensor interface

3 Standard 9-wire interface4 T-Series sensor interface (excluding T050)

Code Terminals

A Solder pins — mounting code R onlyB Screw terminalsC I/O cables, 0,6 meters long — mounting code P onlyD I/O cables, 1,3 meters long — mounting code P onlyE I/O cables, 2,5 meters long — mounting code P only

Code Optional relays and housings

1 None

Code Approvals

M Micro Motion standard (no approvals)U UL Class I, Div. 2, Groups A–D, with non-incendive outputsB CENELEC safe area with intrinsically safe sensor outputs (Model 3500)

Code Language

E EnglishB English for Brazil or ArgentinaF FrenchG German

Code Control application software

Z Process monitor/totalizer (standard) — not available with hardware module code 1D Discrete batch controller

Code Measurement application software

ZZ NoneGZ Enhanced densityBZ Enhanced density with predefined algorithms for food & beverageNZ Net oil computer — control application code Z only

Example:

3500 R 1 A 0 3 A 1 U E D BZ

Model 3500 product matrix

Page 18: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

18 Series 3000 Transmitters and Discrete Controllers

Code Transmitter/controller model

3700 Model 3700 field-mount discrete controller with integrated Coriolis transmitter

Code Mounting options

A Standard

Code Power-supply options

1 85 to 265 VAC2 18 to 30 VDC

Code Communication gateway module

A None

Code Additional hardware module

0 None1 USA - W&M custody transfer — does not meet OIML requirements

Code Sensor interface

3 Standard 9-wire interface4 T-Series sensor interface (excluding T050)

Code Conduit connections

A M20 without conduit glandsB M20 with three increased-safety conduit glandsC M20 with five increased-safety conduit glandsD 3/4-inch NPT without conduit seals

Code Approvals

M Micro Motion standard (no approvals)U UL Class I, Div. 2, Groups A–D, with non-incendive outputsZ CENELEC Zone 1

Code Language

E EnglishB English for Brazil or ArgentinaF FrenchG German

Code Control application software

Z Process monitor/totalizer (standard) — not available with hardware module code 1D Discrete batch controller

Code Measurement application software

ZZ NoneGZ Enhanced densityBZ Enhanced density with predefined algorithms for food & beverageNZ Net oil computer — control application code Z only

Example:

3700 A 1 A 0 3 A U E D BZ

Model 3700 number matrix

Page 19: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

Series 3000 Transmitters and Discrete Controllers 19

Model 3100 product matrix

Series 3000 language codes

Code Document

QREF Quick-reference installation instructions

Code Device

3000R Model 3300/3500 rack mount3000P Model 3300/3500 panel mount3000F Model 3350/3700

Code Language

A DanishD DutchE EnglishB English for Brazil or ArgentinaH FinnishF FrenchG GermanI ItalianN NorwegianP PortugueseS SpanishW Swedish

Example:

QREF 3000R S

Code Accessory model

3100 Model 3100 high-energy relays

Code Device

A 3 relays, 24 to 250 VAC, 5 ampsB 3 relays, 0 to 70 VDC, 5 amps

Code Housing

1 None2 IP65 (Nema 4X) housing for relays only (not Cenelec Zone 2)

Code Approvals

M Micro Motion standard (no approvals)U UL Class I, Div. 2, Groups A–DB CENELEC Zone 2

Code Language for instructions

E EnglishB English for Brazil or ArgentinaF FrenchG German

Example:

3100 A 1A U E

Page 20: Series 3000 Coriolis Transmitters and Discrete Controllers · Product Data Sheet PS-00292-EU January 2001 Series 3000 Coriolis Transmitters and Discrete Controllers

© 2001, Micro Motion, Inc.All rights reservedPS-00292-EU (01/01)

Due to Micro Motion's commitment to continuous improvement of our products, all specifications are subject to change without notice. Micro Motion andELITE are registered trademarks of Micro Motion, Inc., Boulder, Colorado.

Customer ServiceTel +31 318 549 443Fax +31 318 549 449

Micro Motion EuropeGroeneveldselaan 83903 AZ VeenendaalThe NetherlandsTel +31 (0) 318 549 549Fax +31 (0) 318 549 559

Visit us on the Internet atwww.micromotion.com

Micro Motion toll-free numbers (UK only)

Tel. 0800 966 180 / Fax. 0800 966 181