series ultra3 low nox lumiflame … dim 11-09.pdf1150 series ultra3 low no x tm lumiflame...
TRANSCRIPT
1150 SERIES ULTRA3 LOW NOX
TM LUMIFLAME REGENERATIVE BURNER
DIMENSIONS
“D” Catalog No.
1150- inches m 025 48.13 1.22 050 53.88 1.37 075 60.00 1.52 100 64.88 1.65 150 72.13 1.83 200 78.88 2.00 250 85.00 2.16
Dimension from centerline of burner to bottom of case. Not including support structure as shown on drawing.
MANUFACTURED UNDER U.S. PATENT NO. 5,180,300 CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations
11/09
© Bloom Engineering Co 2009 1
1150 SERIES ULTRA3 LOW NOX
TM LUMIFLAME REGENERATIVE BURNER
ALUMINUM APPLICATIONS
Standard 10° Down
Note: Secondary air and exhaust connections are 125# flanges standard. RPM flanges optional. NOTE: GENERAL DIMENSION INFORMATION. SEE BLOOM REPRESENTATIVE FOR CERTIFIED DIMENSIONS FOR CONSTRUCTION. CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations.
11/09
© Bloom Engineering Co 2009 2
1150 SERIES ULTRA3 LOW NOX
TM LUMIFLAME REGENERATIVE BURNER
ALUMINUM APPLICATIONS (cont’d)
Burner Dimensions (inches) Catalog
No. 1150-
Burner Head/Case
Size A B C D E F G H I K L M N P -050-050 -- -- 34 16 33.75 30 43.13 -- 11 .5 6 -- -- -- -075-075 -- -- 34 20 48 30 47.25 -- 13 .5 6 -- -- -- -100-100 -- -- 38 22.5 53.75 34 54.88 -- 14.25 .5 6 -- -- -- -100-150 94.63 99.63 44 22.5 64.25 40 55.63 22.63 14.25 .5 6 39.50 34.63 15.19-150-150 -- -- 44 27.5 64.25 40 55.63 -- -- .5 6 -- -- -- -150-200 104 104.38 48.5 27.5 76.25 44.5 55.88 24 16.75 .5 6 39.50 41.44 18.13-200-200 -- -- 48.5 32 76.25 44.5 55.88 -- 19 .5 6 -- -- -- -200-250 105.38 118.25 55.5 32 80.88 51.5 64.5 26.94 19 .5 6 35.75 41.06 20.5-200-300 124 121.5 52 32 101 48 67.75 26.94 19 .5 6 35.75 41.06 29 -350-350 -- -- 54.75 42 110 50.75 66 -- 24 .5 6 -- -- --
Burner Dimensions (inches) Catalog
No. 1150-
Burner Head/Case
Size R S T U V W Z AA AB AC AD AE AF AG AH
-050-050 -- 8 -- -- 9.13 13.88 -- -- -- -- -- 13.5 11.75 .88 8 -075-075 -- 8 -- -- 15.25 13.88 -- -- -- -- -- 13.5 11.75 .88 8 -100-100 -- 10 6 3 17 16 -- -- -- -- -- 16 14.25 1 12 -100-150 .5 12 6 3 24.13 16 13.19 33.75 32 .88 28 19 17 1 12 -150-150 -- 12 -- -- 24.13 16 -- -- -- -- -- 19 17 1 12 -150-200 .5 14 6 4 24.13 15.88 17.5 39.50 37.38 1.25 28 21 18.75 1.13 12 -200-200 .5 14 6 4 24.13 15.88 -- -- -- -- -- 21 18.75 1.13 12 -200-250 .5 16 6 4 26.31 17.88 17.63 44 41.88 1.25 28 23.5 21.25 1.13 16 -200-300 .5 18 8 4 36.25 19.5 17.63 44 41.88 1.25 28 25 22.75 1.25 16 -350-350 -- 20 -- -- 38.88 19.38 -- -- -- -- -- 27.5 25 1.25 20
Note: -- = not yet existing/designed MANUFACTURED UNDER U.S. PATENT NO. 5,180,300 NOTE: GENERAL DIMENSION INFORMATION. SEE BLOOM REPRESENTATIVE FOR CERTIFIED DIMENSIONS FOR CONSTRUCTION. CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations.
11/09
© Bloom Engineering Co 2009 3
1150 SERIES ULTRA3 LOW NOX
TM LUMIFLAME REGENERATIVE BURNER
STEEL APPLICATIONS
HORIZONTAL FIRING
MANUFACTURED UNDER U.S. PATENT NO. 5,180,300 NOTE: GENERAL DIMENSION INFORMATION. SEE BLOOM REPRESENTATIVE FOR CERTIFIED DIMENSIONS FOR CONSTRUCTION. CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations
11/09
© Bloom Engineering Co 2009 4
1150 SERIES ULTRA3 LOW NOX
TM LUMIFLAME REGENERATIVE BURNER
STEEL APPLICATIONS (cont’d)
Burner Dimensions (inches) Catalog
No. 1150-
Burner Head/Case
Size A B C D E F G H I J K L M N P
-025-025 -- -- 25 11.5 31 21 39.63 -- 8.75 11.75 6 .5 -- -- -- -025-035 47.56 68.38 27 11.5 33.5 23 43.13 16 8.75 11.75 6 .5 22.5 27.94 6.31-035-035 47.56 70.63 27 13.5 33.5 23 43.13 17.25 9.75 13 6 .5 23.25 28.69 5.56-035-050 49.69 70.63 34 13.5 33.75 30 43.13 17.25 9.75 13 6 .5 23.25 28.69 7.56-050-050 49.75 73.88 34 16 33.75 30 43.13 19.25 11 15 6 .5 24.38 30.81 6.5 -050-075 62.13 78.38 34 16 48 30 47.25 19.63 11 15 6 .5 24.38 30.81 11.75-075-075 -- -- 34 20 48 30 47.25 -- 13 -- 6 .5 -- -- -- -075-100 67.75 88.13 38 20 53.75 34 54.88 19.75 13 15.5 6 .5 25.25 32.44 13.75-100-100 -- -- 38 22.5 53.75 34 54.88 -- 14.25 -- 6 .5 -- -- -- -100-150 80.31 91.88 44 22.5 64.25 40 55.63 21.5 14.25 17.25 6 .5 26.94 35.63 19.25-150-150 80.81 97.13 44 27.5 64.25 40 55.63 24.25 16.75 19.75 6 .5 31.5 35.63 15.19-150-200 92.81 97.13 48.5 27.5 76.25 44.5 55.88 24 16.75 19.75 6 .5 31.5 35.63 21.19-200-200 -- -- 48.5 32 76.25 44.5 55.88 -- 19 -- 6 .5 -- -- --
Burner Dimensions (inches)
Catalog No.
1150- Burner
Head/Case Size R S T U V W Z AA AB AC AD AE AF AG AH
-025-025 .38 6 -- -- 8.25 13 -- 22.5 20.75 .88 16 11 9.5 .88 8 -025-035 .38 8 2.5 1.5 9 13.88 9.5 22.5 20.75 .88 16 13.5 11.75 .88 8 -035-035 .38 8 2.5 1.5 9 13.88 10.25 24.5 22.75 .88 20 13.5 11.75 .88 8 -035-050 .38 8 3 1.5 9.13 13.88 10.25 24.5 22.75 .88 20 13.5 11.75 .88 8 -050-050 .38 8 4 2 9.13 13.88 11.38 27 25.25 .88 20 13.5 11.75 .88 8 -050-075 .38 8 4 2 15.25 13.88 11.38 27 25.25 .88 20 13.5 11.75 .88 8 -075-075 .5 8 -- -- 15.25 13.88 -- 31.25 29.5 .88 24 13.5 11.75 .88 8 -075-100 .5 10 6 2.5 17 16 13 31.25 29.5 .88 24 16 14.25 1 12 -100-100 .5 10 -- -- 17 16 -- 33.75 31.75 .88 28 16 14.25 1 12 -100-150 .5 12 6 3 24.13 16 13.94 33.75 31.75 .88 28 19 17 1 12 -150-150 .5 12 6 4 24.13 16 15.94 39.5 37.38 1.25 28 19 17 1 12 -150-200 .5 14 6 4 24.13 15.88 15.94 39.5 37.38 1.25 28 21 18.75 1.13 12 -200-200 .5 14 -- -- 24.13 15.88 -- 44 41.88 1.25 28 21 18.75 1.13 12
Note: -- = not yet existing/designed MANUFACTURED UNDER U.S. PATENT NO. 5,180,300 NOTE: GENERAL DIMENSION INFORMATION. SEE BLOOM REPRESENTATIVE FOR CERTIFIED DIMENSIONS FOR CONSTRUCTION. CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations.
11/09
© Bloom Engineering Co 2009 5
1150 SERIES ULTRA3 LOW NOX
TM LUMIFLAME REGENERATIVE BURNER
MEDIA CASE DIMENSIONS
FOR STEEL AND ALUMINUM APPLICATIONS
General Dimensions (inches/mm) Media Case Size J K L M N P 025* 6 152 31 787 21 533 39.63 1006 8 203 13 330035* 8 203 33.50 851 23 584 43.13 1095 9 229 13.88 352050* 8 203 33.75 857 30 762 43.13 1095 9.13 232 13.88 352075 8 203 48 1219 30 762 47.25 1200 15.25 387 13.88 352100 10 254 53.75 1365 34 864 54.88 1394 17 432 16 406150 12 305 64.25 1632 40 1016 55.63 1413 24.13 613 16 406200 14 356 76.25 1937 44.50 1130 55.88 1419 24.13 613 15.88 403250 16 406 80.88 2054 51.50 1308 64.50 1638 26.31 668 17.88 454300 18 457 101 2565 48 1219 67.75 1721 36.25 921 19.50 495350 20 508 110 2794 50.81 1289 66.00 1676 38.88 987 19.38 492
*Hinged door not available on this size. NOTE: GENERAL DIMENSION INFORMATION. SEE BLOOM REPRESENTATIVE FOR CERTIFIED DIMENSIONS FOR CONSTRUCTION. CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations.
11/09
© Bloom Engineering Co 2009 6
1150 SERIES ULTRA3 LOW NOX
TM LUMIFLAME REGENERATIVE BURNER
ROOF MOUNTED MEDIA CASE
General Dimensions (inches/mm) Approximate Weight
Catalog No.
1100-1150- A B C D E F G H J K lbs kg
59.75 47.0 38.5 33.75 31.0 9.0 28.0 26.0 12.0 11.0 025 1518 1194 978 857 787 229 711 660 305 279
3180 1442
64.25 55.0 42.13 36.5 34.0 12.63 31.63 27.75 12.0 12.0 050 1632 1397 1070 927 864 321 803 705 305 305
4160 1887
80.0 54.5 45.0 50.75 36.0 15.5 34.5 29.25 12.0 12.0 075 2032 1384 1143 1289 914 394 876 743 305 305
5180 2350
86.75 62.5 47.5 56.25 38.0 18.0 37.0 30.5 12.0 14.0 100 2203 1588 1207 1429 965 457 940 775 305 357
6350 2880
102.0 66.0 54.5 66.5 41.0 22.0 41.0 35.5 12.0 14.0 150 2591 1676 1384 1689 1041 559 1041 902 305 357
8090 3670
NOTE: GENERAL DIMENSION INFORMATION. SEE BLOOM REPRESENTATIVE FOR CERTIFIED DIMENSIONS FOR CONSTRUCTION. CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations.
11/09
© Bloom Engineering Co 2009 7