SERUM GLUCAGON KITS Part # 62SGLPEB & 62SGLPEF Test size#: 5 x 200 tests (62SGLPEB), 200 tests (62SGLPEF) - assay volume: 20 µL Revision: 02-Jan.2018 Store at: -60°C or below (62SGLPEB); -60°C or below (62SGLPEF) For research use only. Not for use in diagnostic procedures. ASSAY PRINCIPLE Cisbio Bioassays’ Serum Glucagon assay is only intended for quantitative measurement of Glucagon in plasma and serum using HTRF ® technology. The assay is compatible with human, mouse, rat, and porcine species and is highly specific for pancreatic Glucagon. Glucagon is detected in a sandwich assay format using 2 different specific monoclonal antibodies, one labeled with Terbium Cryptate (donor) and the second with d2 (acceptor). The detection principle is based on HTRF ® technology. When the dyes are in close proximity, the excitation of the donor with a light source (laser or flash lamp) triggers a Fluorescence Resonance Energy Transfer (FRET) towards the acceptor, which in turn fluoresces at a specific wavelength (665 nm). The two antibodies bind to the Glucagon present in the sample, thereby generating FRET. Signal intensity is proportional to the number of antigen-antibody complexes formed and therefore to the Glucagon concentration (Fig. 1). Glucagon Glucagon serum / plasma standard Glucagon Anti-Glucagon donor Antibody Anti-Glucagon acceptor Antibody Figure 1: Principle of HTRF Glucagon sandwich assay. PROTOCOL AT A GLANCE [Glucagon] pg/mL 10 µL Standard or Sample 5 µL Anti-Glucagon acceptor Antibody 5 µL Anti-Glucagon donor Antibody or 10 µL of pre-mixed Anti-Glucagon antibodies ADD READ ANALYSE Incubate 4 hours to overnight @ RT* *Following incubation, the signal remains stable over a period of 48 hours. Make sure to use the set-up for Tb 3+ Cryptate. For more information about set-up and compatible HTRF ® readers, please visit our website at: http://www.cisbio.com/compatible-readers PROTOCOL

Upload: vokhanh

Post on 04-Apr-2018

231 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: SERUM GLUCAGON KITS - Cisbio GLUCAGON KITS ... the donor with a light source (laser or flash lamp) ... 5 µL Anti Glucagon-Tb 3+ Cryptate Repeat Well B1 Repeat Well B1

SERUM GLUCAGON KITS

Part # 62SGLPEB & 62SGLPEFTest size#: 5 x 200 tests (62SGLPEB), 200 tests (62SGLPEF) - assay volume: 20 µLRevision: 02-Jan.2018Store at: -60°C or below (62SGLPEB); -60°C or below (62SGLPEF)For research use only. Not for use in diagnostic procedures.

ASSAY PRINCIPLE

Cisbio Bioassays’ Serum Glucagon assay is only intended for quantitative measurement of Glucagon in plasma and serum using HTRF® technology. The assay is compatible with human, mouse, rat, and porcine species and is highly specific for pancreatic Glucagon.

Glucagon is detected in a sandwich assay format using 2 different specific monoclonal antibodies, one labeled with Terbium Cryptate (donor) and the second with d2 (acceptor). The detection principle is based on HTRF® technology. When the dyes are in close proximity, the excitation of the donor with a light source (laser or flash lamp) triggers a Fluorescence Resonance Energy Transfer (FRET) towards the acceptor, which in turn fluoresces at a specific wavelength (665 nm). The two antibodies bind to the Glucagon present in the sample, thereby generating FRET. Signal intensity is proportional to the number of antigen-antibody complexes formed and therefore to the Glucagon concentration (Fig. 1).

Glucagon Glucagon

serum / plasma standard

GlucagonAnti-Glucagon donor Antibody Anti-Glucagon acceptor Antibody

Figure 1: Principle of HTRF Glucagon sandwich assay.

PROTOCOL AT A GLANCE

[Glucagon] pg/mL10 µL Standard

or Sample5 µL Anti-Glucagon acceptor Antibody

5 µL Anti-Glucagon donor Antibody

or 10 µL of pre-mixed Anti-Glucagon antibodies

ADD READ ANALYSE

Incubate 4 hours to

overnight @ RT*

*Following incubation, the signal remains stable over a period of 48 hours.

Make sure to use the set-up for Tb 3+ Cryptate. For more information about set-up and compatible HTRF® readers, please visit our website at: http://www.cisbio.com/compatible-readers

P R O T O C O L

Page 2: SERUM GLUCAGON KITS - Cisbio GLUCAGON KITS ... the donor with a light source (laser or flash lamp) ... 5 µL Anti Glucagon-Tb 3+ Cryptate Repeat Well B1 Repeat Well B1

MATERIALS PROVIDED:

Kit components 5 x 200 tests *Cat # 62SGLPEB

200 tests *Cat # 62SGLPEF

Glucagon Standard Frozen

1 vial 100 ng/mL

Ref# 62GLCCDA

5 vials 100 ng/mL

Ref# 62GLCCDA

Anti-Glucagon-Tb3+ Cryptate Antibody 1 vial - 20 µLFrozen - 50 X

5 vials - 20 µLFrozen - 50 X

Anti-Glucagon-d2 Antibody 1 vial - 20 µLFrozen - 50 X

5 vials - 20 µLFrozen - 50 X

Diluent #6 ** ready-to-use

1 vial 6 mL

5 vials 6 mL

Detection buffer ***ready-to-use

1 vial 3 mL

Detection Buffer #6

5 vials 3 mL

Detection Buffer #6

* When used as advised, the two available kit sizes will provide sufficient reagents for 500 and 10,000 tests respectively in 20 µL final. Assay volumes can be adjusted proportionally to run the assay in 96 or 1536 well microplates. ** The Diluent is an alternative to medium to prepare working standard solutions. *** The Detection buffer is used to prepare working solutions of acceptor and donor reagents.

PURCHASE SEPARATELY:

• HTRF® 96-well low volume plate Ref# 66PL96001• White 384-well low volume plate *• HTRF®-Certified Reader **. Make sure the setup for Tb3+ Cryptate is used.• Use white plate only * For HTRF microplate recommendations, please visit http://www.cisbio.com/drug-discovery/htrf-microplate-recommendations ** For a list of HTRF-compatible readers and set-up recommendations, please visit http://www.cisbio.com/compatible-readers

STORAGE AND STABILITY

Store the kit at -60°C or below. Under proper storage conditions, reagents are stable until the expiry date indicated on the label.

Reagents

If lyophilized, reconstituted reagents, antibodies, and standard stock solutions may be frozen and thawed only once. To avoid freeze/thaw cycles, it is recommended to dispense remaining stock solutions into disposable plastic vials for storage at -60°C or below for standard and at -20°C or below for antibodies.

Volume of Serum Glucagon standard aliquots should not be under 20 μL.

Thawed diluent and detection buffer can be stored at 2-8°C in your premises.

REAGENT PREPARATION

BEFORE YOU BEGIN:

• It is very important to prepare reagents in the specified buffers. The use of an incorrect diluent may affect reagent stability and assay results.• Thaw all reagents at room temperature, allow them to warm up to room temperature for at least 30 mins before use• Before use, allow Diluent and Detection buffer to warm up at room temperature and homogenize them with a vortex.• It is recommended to filter buffers.• Antibody solutions must be prepared in individual vials and can be mixed prior to dispensing.• Glucagon standards (for standard curve) must be prepared in diluent or in the same medium as the samples.

TAKE CARE TO PREPARE STOCK AND WORKING SOLUTIONS ACCORDING TO THE DIRECTIONS FOR THE KIT SIZE YOU HAVE PURCHASED.

2

Page 3: SERUM GLUCAGON KITS - Cisbio GLUCAGON KITS ... the donor with a light source (laser or flash lamp) ... 5 µL Anti Glucagon-Tb 3+ Cryptate Repeat Well B1 Repeat Well B1

TO PREPARE STANDARD , DILUENT & ANTIBODY STOCK SOLUTIONS:

5 X 200 TESTS KIT - 62SGLPEB 200 TESTS KIT - 62SGLPEF

Anti-Glucagon-Tb3+ Cryptate antibody Thaw the Anti-Glucagon-Tb3+ Cryptate antibody . Mix gently. This 50 X stock solution can be frozen and stored at -20°C or below.

Thaw the Anti-Glucagon-Tb3+ Cryptate antibody . Mix gently. This 50 X stock solution can be frozen and stored at -20°C or below.

Anti-Glucagon-d2 antibodyThaw the Anti-Glucagon-d2 antibody . Mix gently. This 50 X stock solution can be frozen and stored at -20°C or below.

Thaw the Anti-Glucagon-d2 antibody . Mix gently. This 50 X stock solution can be frozen and stored at -20°C or below.

Glucagon Standard Thaw the Glucagon Standard in order to obtain a 100 ng/mL stock solution. Mix gently. This stock solution can be frozen and stored at -60°C or below.

Thaw the Glucagon Standard in order to obtain a 100 ng/mL stock solution. Mix gently. This stock solution can be frozen and stored at -60°C or below.

DiluentThe diluent is ready-to-use.

The diluent is ready-to-use.

TO PREPARE ANTIBODY WORKING SOLUTIONS:

Each well requires 5 µL of Anti-Glucagon-Tb3+ Cryptate Antibody and 5 µL of Anti-Glucagon-d2 Antibody. Prepare the two antibody solutions in separate vials.

5 X 200 TESTS KIT - 62SGLPEB 200 TESTS KIT - 62SGLPEF

Anti-Glucagon- Cryptate antibody

Dilute 50-fold the 50 X stock solution (thawed reagent) of Anti Glucagon-Tb3+ -Cryptate-antibody with the Detection buffer #6: add 1 volume of Cryptate antibody stock solution in 49 volumes of Detection buffer #6 (e.g., 20 µL of reconstituted Cryptate-antibody stock solution + 0.98 mL of Detection Buffer #6).

1 vol 49 vol 1 vol 49 vol Dilute 50-fold the 50 X stock solution (thawed reagent) of Anti-Glucagon-Tb3+ -Cryptate-antibody with the Detection buffer #6: add 1 volume of Cryptate antibody stock solution in 49 volumes of Detection buffer #6 (e.g., 100 µL of reconstituted Crypate-antibody stock solution + 4.9 mL of Detection Buffer #6).

Anti-Glucagon-d2 antibodyDilute 50-fold the 50 X stock solution (thawed reagent) of Anti Glucagon d2-antibody with the Detection buffer #6: add 1 volume of d2-antibody stock solution in 49 volumes of Detection buffer #6 (e.g., 20 µL of reconstituted d2-antibody stock solution + 0.98 mL of Detection Buffer #6).

1 vol 49 vol 1 vol 49 vol Dilute 50-fold the 50 X stock solution (thawed reagent) of Anti Glucagon d2-antibody with the Detection buffer #6: add 1 volume of stock solution in 49 volumes of Detection buffer #6 (e.g., 100 µL of reconstituted d2-antibody stock solution + 4.9 mL of Detection Buffer #6).

Antibody mix

It is possible to pre-mix the two ready-to-use antibody solutions just prior to dispensing the reagents by adding 1 volume of d2-antibody solution to 1 volume of Cryptate-antibody solution (e.g. 1 mL of d2-antibody + 1 mL of Cryptate-antibody).

It is possible to pre-mix the two ready-to-use antibody solutions just prior to dispensing the reagents by adding 1 volumes of d2-antibody solution to 1 volume of Cryptate-antibody solution (e.g. 5 mL of d2-antibody + 5 mL of Cryptate-antibody).

3

Page 4: SERUM GLUCAGON KITS - Cisbio GLUCAGON KITS ... the donor with a light source (laser or flash lamp) ... 5 µL Anti Glucagon-Tb 3+ Cryptate Repeat Well B1 Repeat Well B1

TO PREPARE STANDARD WORKING SOLUTIONS:

• Each well requires 10 µL of standard.• Dilute the standard stock solution serially with diluent #6 • In order to check for a potential interference effect from your assay buffer when using the assay for the first time, we highly

recommend the parallel preparation of a standard curve in your own supplemented cell culture medium and in diluent #6 .• In order to counteract any standard sticking, we recommend changing tips between each dilution.

A recommended standard dilution procedure is listed and illustrated below:

Dilute the standard stock solution 50-fold with diluent #6 to prepare high standard (Std 8) for the top of the curve: e.g. take 4 µL of standard stock solution and add it to 196 µL of diluent #6 . Mix gently.

Use the high standard (Std 8) to prepare the standard curve using 1/2 serial dilutions as follows:

• Dispense 100 µL of diluent #6 in each vial from Std 7 to Std 0.

• Add 100 µL of standard to 100 µL of diluent #6 , mix gently and repeat the 1/2 serial dilution to make standard solutions: std7, std6, std5, std4, std3, std2, std1.

This will create 8 standards for the analyte. Std 0 (Negative control) is diluent #6 or appropriate culture medium alone.

100 µL100 µL100 µL100 µL4 µL

Glucagon

Std0

Std..

Std1

Std..

Std 7

diluent #6 or appropriate medium

100 µL

diluent #6 or appropriate medium

Std 8

196 µL

* Standard curve can be prepared in other appropriate medium

4

Page 5: SERUM GLUCAGON KITS - Cisbio GLUCAGON KITS ... the donor with a light source (laser or flash lamp) ... 5 µL Anti Glucagon-Tb 3+ Cryptate Repeat Well B1 Repeat Well B1

TO PREPARE SAMPLES:

• Each well requires 10 µL of sample.• Just after their collection, put the samples at 4°C and test them immediately. For later use, samples should be dispensed into disposable plastic vials and stored at -60°C or below. Avoid multiple freeze/thaw cycles.• In order to prepare plasma samples, we recommend collecting blood in EDTA-tubes• Samples with a concentration above the highest standard (Std 8) must be diluted in diluent #6 or in your appropriate sample medium.• Avoid the use of samples with a high degree of hemolysis• Many proteases present into the blood may degrad Glucagon. In order to avoid any degration, blood sample should be drawn into tubes containing Aprotinin (500 KIU/ mL of whole blood). Alternately, Aprotinin has to be added immediately after blood collection

ASSAY PROTOCOL

Standard (Std 0 - Std 8) Samples

Step

1 Dispense 10 µL of each Glucagon standard (Std 0 - Std 8) into each standard well Dispense 10 µL of each sample into each sample well

Step

2

Add 5 µL of Anti-Glucagon-d2 working solution to all wells

Step

3

Add 5 µL of Anti Glucagon-Tb3+ Cryptate working solution to all wells

Step

4

Seal the plate and incubate 4 hours to overnight @ RT* at room temperature

Step

5

Remove the plate sealer and read on an HTRF® compatible reader

5

Page 6: SERUM GLUCAGON KITS - Cisbio GLUCAGON KITS ... the donor with a light source (laser or flash lamp) ... 5 µL Anti Glucagon-Tb 3+ Cryptate Repeat Well B1 Repeat Well B1

1 2 3 4 5 6

A10 µL Std 0 (Negative control) 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well A1 Repeat Well A1

10 µL Sample 1 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well A4 Repeat Well A4

B10 µL Std 1 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well B1 Repeat Well B1

10 µL Sample 2 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well B4 Repeat Well B4

C10 µL Std 2 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well C1 Repeat Well C1

10 µL Sample 3 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well C4 Repeat Well C4

D10 µL Std ... 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well D1 Repeat Well D1

10 µL Sample ... 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well D4 Repeat Well D4

E10 µLStd ... 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well E1 Repeat Well E1

10 µL Sample ... 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well E4 Repeat Well E4

F10 µL Std ... 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well F1 Repeat Well F1

10 µL Sample ... 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well F4 Repeat Well F4

G10 µL Std ... 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well G1 Repeat Well G1

10 µL Sample ... 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well G4 Repeat Well G4

H10 µL Std ... 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well H1 Repeat Well H1

10 µL Sample ... 5 µL Anti-Glucagon-d2 5 µL Anti Glucagon-Tb3+ Cryptate

Repeat Well H4 Repeat Well H4

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24ABCDEFGEHIJKLMNOP

6

Page 7: SERUM GLUCAGON KITS - Cisbio GLUCAGON KITS ... the donor with a light source (laser or flash lamp) ... 5 µL Anti Glucagon-Tb 3+ Cryptate Repeat Well B1 Repeat Well B1

DATA REDUCTION & INTERPRETATION

1. Calculate the ratio of the acceptor and donor emission signals for each individual well.

Ratio = Signal 665 nm

Signal 620 nm x 104

2. Calculate the % CVs. The mean and standard deviation can then be worked out from ratio replicates.

CV (%)= Standard deviation

Mean Ratio x 100

3.the role of an internal assay control. Delta F is used for the comparison of day to day runs of the same assay.

delta F (%) =Ratio Standard or sample - Ratio Negative Control

Ratio Negative Controlx 100

Calculate the % delta F which reflects the signal to background of the assay. The negative control (Standard 0) plays

For more information about data reduction, please visit http://www.cisbio.com/htrf-ratio-and-data-reduction

RESULTS

This data must not be substituted for the data obtained in the laboratory and should be considered only as an example (readouts on PHERAstar Plus with a flash lamp). Results may vary from one HTRF® compatible reader to another.

Standard curve fitting with the 4 Parameter Logistic (4PL) model:

7

Page 8: SERUM GLUCAGON KITS - Cisbio GLUCAGON KITS ... the donor with a light source (laser or flash lamp) ... 5 µL Anti Glucagon-Tb 3+ Cryptate Repeat Well B1 Repeat Well B1

FOR MORE INFORMATION Europe and other countries +33(0)466-796-705 U.S. and Canada 1-888-963-4567 China +86-21-5018-9880 Japan +81-(0)43-306-8712 Visit www.cisbio.com to find a list of our regional distributors

This product contains material of biologic origin. Use for research purposes only. Do not use in humans or for diagnostic purposes. The purchaser assumes all risk and responsibility concerning reception, handling and storage. The use of the cell line will be done with appropriate safety and handling precautions to minimize health and environmental impact. Remaining disclaimer.

Copyright 2016 Cisbio Bioassays. All rights reserved. HTRF and and the HTRF logo are trademarks or registered trademarks of Cisbio Bioassays.

Page 9: SERUM GLUCAGON KITS - Cisbio GLUCAGON KITS ... the donor with a light source (laser or flash lamp) ... 5 µL Anti Glucagon-Tb 3+ Cryptate Repeat Well B1 Repeat Well B1

Thaw antibodies & Glucagon standard.

1

See assay recommendations on next page

SERUM GLUCAGON KITS

S H O R T P R O T O C O L : P ar t # 6 2SGL P E B (5 x 2 0 0 t es t s) & 6 2 SGL P E F (2 0 0 t es t s) - as s ay vo lume: 2 0 µ L

Allow the reagents to warm up to room temperature for at least 30 mins before use.

Prepare standard curve (Std8-Std1) by making 1:2 serial dilutions from Std8 in diluent # 6 1 X or other appropriate medium. Mix between each dilution.Std 8 is obtained by diluting 50-fold the glucagon stock solution.3

Seal the plate and incubate 4 hours to overnight at RT. The best sensitivity is reached after ON incubation time.6

Prepare conjugate working solutions 1 X (from 50 X see table on next page) using detection buffer by diluting 50-fold the stock solutions.2

Dispense the antibody solutions in all wells: 5 µL of anti Glucagon-cryptate-antibody and 5 µL of anti Glucagon-d2-antibody or 10 µL of the 2 pre-mixed antibodies.5

Remove the plate sealer and read on an HTRF® compatible reader.

7

Dispense standard curve and sample in their dedicated well*: Add 10 µL of each standard (Std 8 to Std 0) and 10 µL of sample.4

Page 10: SERUM GLUCAGON KITS - Cisbio GLUCAGON KITS ... the donor with a light source (laser or flash lamp) ... 5 µL Anti Glucagon-Tb 3+ Cryptate Repeat Well B1 Repeat Well B1

FOR MORE INFORMATION Europe and other countries +33(0)466-796-705 U.S. and Canada +1-888-963-4567 China +86-21-5018-9880Japan +81(0)43-306-8712 Visit www.cisbio.com to find a list of our regional distributors

This product contains material of biologic origin. Use for research purposes only. Do not use in humans or for diagnostic purposes. The purchaser assumes all risk and responsibility concerning reception, handling and storage.

Copyright 2017 Cisbio, France. All rights reserved. HTRF®, Tag-lite®, and EPIgeneous™ are trademarks or registered trademarks of Cisbio All other trademarks are the property of their respective owners.

KIT SIZE ANTI-GLUCAGON DONOR ANTIBODY ANTI-GLUCAGON ACCEPTOR ANTIBODY

Concentrations after thawing Concentrations after thawing

200 TESTS 50 X 50 X

5 X 200 TESTS 50 X 50 X

GLUCAGON STANDARD200 TESTS &5 X 200

TESTS 50 X

S H O R T P R O T O C O L - R E C O M M E N D A T I O N S

Store the kit at -60°C or below until the expiration date indicated on the labels.

It is very important to prepare reagents in the specified buffers. The use of an incorrect diluent may affect reagent stability and assay results.

Thaw all reagents at room temperature, allow them to warm up to room temperature for at least 30 mins before use.

It is recommended to filter buffers (diluent & detection buffer).

After first opening, store the diluent at -20°C.

Volume of Serum Glucagon aliquots should not be under 20 μL.

Standard curve must be prepared in diluent or in the same medium as the samples.

For standard curve preparation, in order to prevent any standard carry-over we recommend changing tips between each dilu-tion.

Many proteases present into the blood may degrad Glucagon. In order to avoid any degration, blood sample should be drawn into tubes containing Aprotinin (500 KIU/mL of whole blood). Alternately, Aprotinin has to be added immediately after blood collection.

In order to prepare plasma samples, we recommend collecting blood in EDTA-tubes.

Avoid the use of samples with a high degree of hemolysis.