servi and troubleshoo de - ceienterprises.com · ©2017 cei enterprises, inc. 2 ztnd 050200 aa 002...
TRANSCRIPT
Service and Troubleshooting Guide
Publication # 17-09-033
a publication of CEI Service & Parts Dept: 800.545.4034
1
How to determine impeller sizeon Sterling-SIHI hot oil pumps used by CEI
When replacing hot oil pumps, there are two key pieces of information you'll need to know. One, obviously, is the size of the pump (Figure 2).
The other is the size of the impeller that is in the pump.
Not all pumps of a given size will have the same size impeller. Depending on the application, the standard size impeller that the pump usually comes with may be too large. If so, the impeller may give too much resistance, resulting in excessive draw, tripping breakers, and likely causing other problems.
In these cases, the factory may trim the impeller to a more suitable size so that the pump will function reliably in its intended application.
On the Sterling-SIHI hot oil pumps used by CEI, the size of a trimmed impeller will be stamped or engraved on an information plate. This plate is attached to the casing of the pump (Figure 1).
The information plate denotes the size of the pump, as shown in Figure 3. The example shown is for a ZTND 050200. The standard impeller size for this pump is 214mm. The only visible indication that the pump is fitted with a standard size impeller is the lack of an additional marking in the field indicated in Figure 3.
If the factory trims the impeller, the size of the trimmed impeller will be stamped or engraved in this field (Figure 4).
Figure 1. Location of the information plate on a Sterling- SIHI hot oil pump.
Figure 2. Location of the pump impeller.
Impeller
CEI Service & Parts: 800.545.4034245 Woodward Rd. SE | Albuquerque, New Mexico 87102 | USA
©2017 CEI Enterprises, Inc. 2
ZTND 050200AA 002 1B 2GB
Pp-no. ES 1712310-08
m3/h nn
kg/l 2017180
|| 2G c T1-T5
% [---,-]
P kW t °Crpm
ZTND 050200AA 002 1B 2GB
Pp-no. ES 1712310-08
m3/h nn
kg/l 2017
|| 2G c T1-T5
% [---,-]
P kW t °Crpm
214ZTNC ZTND or older, ZTNY
ZTND 050200AA 002 1B 2GB
Pp-no. ES 1712310-08
m3/h nn
kg/l 2017180
|| 2G c T1-T5
% [---,-]
P kW t °Crpm
ZTND 050200AA 002 1B 2GB
Pp-no. ES 1712310-08
m3/h nn
kg/l 2017
|| 2G c T1-T5
% [---,-]
P kW t °Crpm
214ZTNC ZTND or older, ZTNY
Figure 3. Location of the pump size on the information plate. Note that this plate has no additional marking in the lower left field, indicating a full-size impeller.
Figure 4. This information plate denotes that the pump is fitted with a 180mm impeller.
THIS PUMP HAS A FULL-SIZE IMPELLER
THIS PUMP HAS A TRIMMED IMPELLER
PUMP SIZE