ServiceManual Philips Consumer Lifestyle Published by Philips Consumer Lifestyle Printed in the Netherlands © Copyright reserved Subject to modification Steam Generator GC9220 11/08 PRODUCT INFORMATION Fast & powerful crease removal - Soleplate: SteamGlide - OptimalTemp - Continiuous steam output: 120 g/min - Steam boost: 230 g/min - Vertical steam - Steam pressure: Up to 5 bar - Steam tip - Power: 2400 W Easy to use - Water tank capacity: 1500 ml - Filling and emptying water: Detachable water tank Extra large opening door - Refill any time - Heat-up time: 2 min - Hose storage: Hose storage compartment - Cord storage: Cord storage compartment - Power cord lenght: 1.8 m - Cord freedom (swivel): 180 degree cord freedom - Hose length: 1.7 m - Safe for all fabrics: Even for delicates like silks Calc management - Suitable for tap water - Calc clean solution: Easy De-calc - Calc clean reminder EMF & Service Information - This product meets the requirements regarding interference suppression on radio & TV. - After the product has been repaired, it should function properly & has to meet the safety requirements as officially laid down at this moment. TECHNICAL INFORMATION Voltage : 220 - 240 V Frequency : 50 - 60 Hz Power - Iron : 800 W at 230 V - Boiler : 1370 W at 230 V Dimension (F-box) : 491 mm x 305 mm x 335 mm (Depth x Width x Height) Weight : Weight of iron: 1.2 kg Weight of iron + base: 5 kg Optimal Temp technology - Delivers always perfect combination of steam and temperature - 100% easy to use, no adjustment required - 100% safe on all ironable garments - 100% effective on all fabrics, no other iron is faster - Tested and approved by independent textile experts Always the perfect setting thanks to: 1 - Cylonic steam chamber 2 - Advanced Smart control processor Easy De-calc Easy De-calc cap allows hassle free & effective scale removal to extend the life of the steam generator. 1 2

Upload: hoangtruc

Post on 07-Jul-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

Service ManualPhilips Consumer Lifestyle

Published by Philips Consumer Lifestyle Printed in the Netherlands © Copyright reserved Subject to modification

Steam Generator

GC9220

11/08

PRODUCT INFORMATION

Fast & powerful crease removal- Soleplate: SteamGlide- OptimalTemp- Continiuous steam output: 120 g/min- Steam boost: 230 g/min- Vertical steam- Steam pressure: Up to 5 bar- Steam tip- Power: 2400 W

Easy to use- Water tank capacity: 1500 ml- Filling and emptying water: Detachable water tank

Extra large opening door- Refill any time- Heat-up time: 2 min- Hose storage: Hose storage compartment- Cord storage: Cord storage compartment- Power cord lenght: 1.8 m- Cord freedom (swivel): 180 degree cord freedom- Hose length: 1.7 m- Safe for all fabrics: Even for delicates like silks

Calc management- Suitable for tap water- Calc clean solution: Easy De-calc- Calc clean reminder

EMF & Service Information- This product meets the requirements regarding interference

suppression on radio & TV.- After the product has been repaired, it should function

properly & has to meet the safety requirements as officially laid down at this moment.

TECHNICAL INFORMATIONVoltage : 220 - 240 VFrequency : 50 - 60 HzPower - Iron : 800 W at 230 V - Boiler : 1370 W at 230 VDimension (F-box) : 491 mm x 305 mm x 335 mm

(Depth x Width x Height)Weight : Weight of iron: 1.2 kg

Weight of iron + base: 5 kgOptimal Temp technology- Delivers always perfect combination of steam and temperature- 100% easy to use, no adjustment required- 100% safe on all ironable garments- 100% effective on all fabrics, no other iron is faster- Tested and approved by independent textile experts

Always the perfect setting thanks to: 1 - Cylonic steam chamber 2 - Advanced Smart control processor

Easy De-calcEasy De-calc cap allows hassle free & effective scale removalto extend the life of the steam generator.

1

2

GC9220

2-12

BACKPLATE ASSY 16

SOS KNOB 13

INLAY MOLDED 17

MICRO-SWITCH ASSY 12

HOSE CORD MOUNTEDASSY SOS 15

HOUSING & LENSASSY PRINTED 9

LIGHT GUIDE ASSY 10

COVER MOLDED SOS 8

DEVIATOR ASSY 3

SOLEPLATE MOUNTEDASSY 1

Remove Screw ADisassemble BACKPLATE SCREW PLATE 21Remove Screws B1, B2Disassemble BACKPLATE ASSY 16Remove Screws C1, C2Remove Cord clampDisassemble SOS KNOB COVER 18

Tip for disassembling SOS KNOB COVER 18:Carefully insert a sharp object into the gap at the side & slowly lift up the part

Disassemble SOS KNOB 13Remove Screw DDisassemble INLAY MOLDED 17Remove Screw EDisassemble MICRO-SWITCH ASSY 12Remove Screw FDisassemble HOUSING & LENS ASSY PRINTED 9Remove Screws G1, G2Disassemble LIGHT GUIDE ASSY 10Remove Screws H1 - H3Disassemble COVER MOLDED SOS 8Remove Screws J1 - J6Disassemble DEVIATOR ASSY 3

DISASSEMBLY ADVICE - IRON

GC9220

3-12

PARTS LIST - IRON

Pos Service code Description

12345

6789

10

1112131415

1617181920

21

4239 021 613714239 021 614714239 021 615234239 015 591514239 010 11991

4239 010 102814239 015 701534239 026 446214239 021 657414239 021 61771

4239 021 643614239 021 615614239 021 655314239 026 424814239 021 63482

4239 021 634914239 026 446514239 026 425214239 026 425314239 014 54961

4239 026 42551

Soleplate mounted assy 230 V / 800 WThermistor assy IronDeviator assyBraided rubber hose ironHose clip (ID=8.7)

Hose clip-Braided rubber hoseRyton ringCover molded SOSHousing & Lens assy printedLight Guide assy

Deco_Plate & top Cover assy printedMicro-switch assySOS knob sprayed paintedSOS lever moldedHose cord mounted assy SOS

Backplate assyInlay moldedSOS knob coverTrigger moldedTrigger spring

Backplate screw cap

GC9220

4-12

EXPLODED VIEW - IRON

18

13

17

14

20

19

9

8

3

1

Rubber gasket

21

5

11

12

Micro Switch holder

Cord clamp

2

6

4

7

D E

F

H2G1 G2

C1

B2

B1

A1

C2

H1

H3

J2

J6J5

J4

J1J3

15

10

16

GC9220

5-12

DISASSEMBLY ADVICE - STAND

WATER TANK PRINTEDASSY 58

TRAY MOLDED 53

DISPLAY COVER PRINTED ASSY 50

STAND TOP MOLDED 45

POWER CORD STORAGE MOLDED 42

HOSE CORD STORAGE COMPARTMENT ASSY 43

RINSE CAP ASSY 56

RINSE HOUSINGPRINTED 39

BOILER ASSY 36

BUTTON PANEL ASSY 51

POWER BOARD PCBASSY 60

Remove WATER TANK PRINTED ASSY 58Remove TRAY RUBBER CAP 54Remove Screws K1, K2Disassemble TRAY MOLDED 53Remove Screws L1 - L4Remove Screw MRemove Screws N1 - N4Disassemble DISPLAY COVER PRINTED ASSY 50Remove Screws P1 – P3Disassemble STAND TOP MOLDED 45Remove Screws Q1, Q2Disassemble POWER CORD STORAGE MOLDED 42 Disassemble HOSE CORD STORAGE COMPARTMENT ASSY 43Remove RINSE CAP ASSY 56Remove Screws R1, R2Disassemble RINSE HOUSING PRINTED 39Remove Screws S1, S2, S3Disassemble BOILER SUPPORT BRACKET MOLDED 41Disassemble BOILER ASSY 36Remove Screws T1, T2Disassemble BUTTON PANEL ASSY 51Remove Screw UDisassemble POWER BOARD PCB ASSY 60

GC9220

6-12

PARTS LIST - STAND

Pos Service code Description

3031323334

3536373839

4041424344

4546474849

5051525354

5556575859

60

4239 021 635314239 021 616014239 026 420814239 015 592014239 010 10261

4239 026 321814239 021 616114239 017 109024239 021 618124239 021 65611

4239 026 316414239 026 425814239 026 447314239 021 635514239 000 11571

4239 026 447614239 026 447714239 014 549824239 021 635614239 026 44801

4239 021 635714239 021 635914239 021 636014239 026 448514239 015 59221

4239 015 592314239 021 636114239 015 582014239 021 636214239 021 61721

4239 021 61652

Stand bottom assyPump assyDe-air valveBraided rubber hose boilerInox clamp

Spacer Bottom moldedBoiler assyElectrovalveThermistor assy BoilerRinse Housing printed

Spacer top moldedBoiler support bracket moldedPower cord storage moldedHose cord storage compartment assyCord set EU

Stand top moldedTank Catch moldedTank Catch SpringInlet coupling plate weldedDe-air coupling molded

Display cover printed assyButton panel assyFront Bracket assyTray moldedTray rubber cap

Rinse Rubber BushRinse cap assyO-ringWater tank printed assyHall sensor PCBA assy

Power Board PCB assy

GC9220

7-12

EXPLODED VIEW - STAND

58

46

35

37

49

48

45

43

31

59

30

32

52

53

42

40

36

41

39

56

57

60

38

34

33

44

55

54

47

L1L2

L3

P2

K2K1

P3

P1 M

Q2

Q1

S1

T2

T1

U

R2R1

N1

N2

N4

N3

S3

S2

L4

50

51

Cordclamp

GC9220

8-12

ELECTRICAL BLOCK DIAGRAM

IronLED

STAND IRON

Power Board

LL

Stand Electronics

Hall SensorBoard

UI Board

Thermistor

Pump SteamE-valve Boiler Heating

Element

ThermalFuseM

NN

N

L

E

EE

Thermistor

TriggerSwitch

IronHeatingElement

ThermalFuse

GC9220

9-12

WIRING DIAGRAM

LEGEND:

Female Push-on 4.8 x 0.8 mm L-shape Connector

Female Push-on 5.2 x 0.8 mm L-shape Connector

Male Tab Terminal 4.8 x 0.8 mm

Female Push-on L-shape Connector 6.35 x 0.8 mm

Piggy Back Push-on Connector 4.8 x 0.8 mm

Male Tab Terminal 6.35 x 0.8 mm

Female Push-on Connector 6.35 x 0.8 mm

Sleeve - Fiber Glass

Insulated Tab - Silicon Rubber

Ring Terminal M4.3

Splice 6.0 mm

Directly soldered on PCB

7-pin Board-in Connector 2 mm (horizontal)

7-pin Connector 2 mm (vertical)

POWER BOARD

HALLSENSORBOARD

HOSCORD

FLEX ASSY IRON

UI BOARD

9013

(Li

ve)

9016

(P

ump-

Con

trol

)

9015

(E

valv

e-C

ontr

ol)

THERMALFUSE (L)

TH

ER

MIS

TOR

TR

IGG

ER

NE

UT

RA

L

9014

(Li

ve)

WA

1 : P

CB

-Pum

p (L

)

WA

2 : P

CB

-Pum

p (c

trl)

WA

7 : P

CB

-EV

(ct

rl)

WA

4 : P

CB

-EV

(L)

WA

5 : P

CB

-Fus

e (L

)WA19 : HE-Fuse (L)

WA

6 : P

CB

-Fus

e (N

)

9003

(B

oile

r-L)

3

2

1

3

2

1

2

1

9009

(B

oile

r-N

)

9001

(Li

ve)

9002

(N

eutr

al)

9018 (Iron LED)

9007

9004 (Iron Live)

9006

(To

UI)

PUMP

EVALVE-EARTH

7x

2x

3x

H

VsF

sFsF

F

sFm

F

mF

sF

sF

sF sPB

sM

sM

F

M

sF

FF

M M #1

#1

#2

#1

#1

#2

#2

THERMALFUSE (N)

sFsF

#2#1

#2

F

F

F

H

V

M

M

M

WA20 : HE-Fuse (N)

WA

3 : E

AR

TH

WIR

E_B

OIL

ER

THERM-BOILER

sPB

9012

(3.96 mm)9017

GC9220

10-12

REPAIR INSTRUCTIONS

- Due to the high wattage of the iron, only the specified cord set must be used.- Should damage be observed on the HOSE CORD MOUNTED ASSY 15 or CORD SET 44, they must be replaced.

Continued usage is not allowed.- When replacing the MICROSWITCH ASSY 12, please dress the 2 attached wires such that they are free of tension. Pulling force

on the wires may affect the steam triggering.- To avoid damage to the sealing & components of the BOILER ASSY 36, NEVER clean the boiler assy with vinegar, descaling

agent or other corrosive chemicals.- When replacing ELECTROVALVE 37 or PUMP ASSY 31, please be reminded to apply loctite at the joints for good sealing.- After the product has been repaired, it should function properly and has to meet the safety requirements & legal regulations as

laid down & officially established at this moment.- The following tests are common checks that are conducted on a repaired product before it is returned to the consumer.

1. Soleplate temperatureCheck that soleplate temperature is within IEC requirement.

Measure the temperature of the soleplate after the iron has reached steady state i.e connected to the mains for at least 15 minutes. The table below shows the temperature requirement.

MarkingSoleplate temperature (Deg C)

Material, for example

Test-point

=

=

Minimum Maximum Nominal + Tolerance

• (1 dot) 70 120 95 ± 25 Acetate, elastane, polyamide, polyproylene

•• (2 dots) 100 160 130 ± 30 Cupro, polyester, silk, triacetate, viscose, wool

••• (3 dots) 140 210 175 ± 35 Cotton, linen

2. Leakage currentCheck that leakage current is within IEC requirement.

Measure leakage current between LIVE/NEUTRAL & EARTH.IEC requirement is that at 230 V supply, the EARTH leakage current must be less than 0.75 mA.

3. Water leakage / FunctionalityCheck that there is no water leakage from any part of the product during operation.

Check that the functionality of the product (product dependent) eg. steaming, variable steam, SOS, ASO etc is working properly.

4. Loose partCheck that there are no loose parts eg. extra screw in the product that can cause short-circuit or product malfunction.

GC9220

11-12

REPAIR INSTRUCTIONS

5. Crimping INOX CLAMP 34When exchanging BOILER ASSY 36 or DE-AIR VALVE 32 or BRAIDED RUBBER HOSE BOILER 33, it is necessary to replace the INOX CLAMP 34. Below instructions ensure that the inox clamp is crimped correctly.

CAUTION: When crimping on plastic part like DE-AIR VALVE, avoid over crimping which may lead to plastic part crack.

Inox clamp Crimping tool

Knipex Crimping tool

2.7 mm(max)

1 - 2 mm

Distance from edge ofcrimp to rubber hose

Fold in crimpDirect crimp form

3.5 mm(max)

GC9220

12-12

REPAIR INSTRUCTIONS

6. Replacing ELECTROVALVE 37To prevent damage to the electrovalve during service activity, please observe below precautions during disassembly & reassembly.

Tools required: Torque wrench (set to 6 kgf)

CAUTION #1: The torque wrench engagement is allowed ONLY at the yellow box locations in below picture.

CAUTION #2: Ensure torque wrench jaw does not contact the solenoid body.

Contact area for torquewrench to screw/unscrewthe electrovalve.

Torque wrench

Electro-valvesolenoid body

Maintain gap betweenthe torque wrench and

the solenoid body