service rinnova cond x inovia cond inovia in circuito comando rinnova cond x inovia cond inovia in...

43
Service Service RinNOVA Cond X RinNOVA Cond X Inovia Cond Inovia Cond Inovia IN Inovia IN CIRCUITO COMANDO CIRCUITO COMANDO

Upload: porfirio-scarpa

Post on 01-May-2015

250 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServiceService

RinNOVA Cond XRinNOVA Cond XInovia CondInovia CondInovia IN Inovia IN

CIRCUITO COMANDOCIRCUITO COMANDO

Page 2: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

PANNELLO COMANDOPANNELLO COMANDO

– DISPLAY LCD 70 mm X 50 mmDISPLAY LCD 70 mm X 50 mmDISPAY LCD 45 mm x 30 mm -DISPAY LCD 45 mm x 30 mm -

– TASTI TEMPERATURA SANITARIOTASTI TEMPERATURA SANITARIOTASTI TEMPERATURA SANITARIO -TASTI TEMPERATURA SANITARIO -

– TASTI TEMPERATURA RISCALDAMENTOTASTI TEMPERATURA RISCALDAMENTOTASTI TEMPERATURA RISCALDAMENTO -TASTI TEMPERATURA RISCALDAMENTO -

– SELETTORE STAGIONALE + ON/OFFSELETTORE STAGIONALE + ON/OFFSELETTORE STAGIONALE + ON/OFF + RESET -SELETTORE STAGIONALE + ON/OFF + RESET -

– TASTO ATTIVAZIONE PRERISCALDOTASTO ATTIVAZIONE PRERISCALDONON PRESENTE (combinazione di tasti) -NON PRESENTE (combinazione di tasti) -

– TASTO MENU’ INFOTASTO MENU’ INFONON PRESENTE (combinazione di tasti) –NON PRESENTE (combinazione di tasti) –

– TASTO RESETTASTO RESETTASTO RESET E ON/OFF MULTIFUNZIONE -TASTO RESET E ON/OFF MULTIFUNZIONE -

M260 M / M261 MM260 M / M261 M

PANNELLO COMANDI “MEDIUM”PANNELLO COMANDI “MEDIUM”M260 T M260 T

PANNELLO COMANDI “TOP”PANNELLO COMANDI “TOP”

Page 3: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

INDICAZIONI DISPLAY TOPINDICAZIONI DISPLAY TOP

REMOTO COLLEGATO;REMOTO COLLEGATO;

SE LAMPEGGIANTE SE LAMPEGGIANTE RICHIESTA IN ATTORICHIESTA IN ATTO POMPA ALIMENTATAPOMPA ALIMENTATA

PRESENZA FIAMMA E PRESENZA FIAMMA E LIVELLO DI LIVELLO DI MODULAZIONEMODULAZIONE

TEMP. ESTERNA TEMP. ESTERNA (SE COLLEGATA S.E.)(SE COLLEGATA S.E.)

ANTIGELOANTIGELO

PRESSIONE IN PRESSIONE IN CALDAIACALDAIA

SCADENZA SCADENZA MANUTENZIONEMANUTENZIONE

PRERISCALDO ATTIVO;PRERISCALDO ATTIVO;

SE LAMPEGGIANTE SE LAMPEGGIANTE PRERISCALDO IN ATTOPRERISCALDO IN ATTO

RICHIESTA RICHIESTA RISCALDAMENTORISCALDAMENTO

INGRESSO MENU’ INFOINGRESSO MENU’ INFO

LIVELLO INTEGRAZIONE LIVELLO INTEGRAZIONE SOLARESOLARE

ATTESA RIACCENSIONE ATTESA RIACCENSIONE BRUCIATOREBRUCIATORE

SPAZZACAMINO SPAZZACAMINO ATTIVOATTIVO

Page 4: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

INDICAZIONI DISPLAY MEDIUMINDICAZIONI DISPLAY MEDIUM

RICHIESTA RICHIESTA INTERVENTO INTERVENTO TECNICOTECNICO

PRESENZA FIAMMA PRESENZA FIAMMA

SANITARIO ATTIVO;SANITARIO ATTIVO;

SE LAMPEGGIANTE SE LAMPEGGIANTE RICHIESTA IN ATTORICHIESTA IN ATTO

RISCALDAMENTO ATTIVO;RISCALDAMENTO ATTIVO;

SE LAMPEGGIANTE SE LAMPEGGIANTE RICHIESTA IN ATTORICHIESTA IN ATTO

RICHIESTA SBLOCCO RICHIESTA SBLOCCO

Page 5: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

SCHEMA ELETTRICO RINNOVA COND XSCHEMA ELETTRICO RINNOVA COND X

SCHEDA SIT SCHEDA SIT 14064 120814064 1208

Page 6: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

SCHEMA ELETTRICO INOVIA INSCHEMA ELETTRICO INOVIA IN

SCHEDA SIT SCHEDA SIT 14064 120814064 1208

Page 7: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

SCHEMA ELETTRICO INOVIA CONDSCHEMA ELETTRICO INOVIA COND

SCHEDA SIT SCHEDA SIT 14064 120814064 1208

Page 8: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

COLLEGAMENTI ELETTRICICOLLEGAMENTI ELETTRICI

COLLEGAMENTI ELETTRICI ESTERNI

ALLOGGIAMENTO ALLOGGIAMENTO SCHEDA COMANDO E SCHEDA COMANDO E CONNESSIONI CONNESSIONI ELETTRICHE ESTERNEELETTRICHE ESTERNE

Page 9: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

COLLEGAMENTI ELETTRICICOLLEGAMENTI ELETTRICICOLLEGAMENTI ELETTRICI ESTERNI AUSILIARI M260T /

M261MM260TM260TSCHEDA AUSILARE PER SCHEDA AUSILARE PER EVENTUALE VALVOLA EVENTUALE VALVOLA DI ZONADI ZONA

M261MM261MSCHEDA AUSILARE PER SCHEDA AUSILARE PER ELETTROVALVOLA DI ELETTROVALVOLA DI RIEMPIMENTORIEMPIMENTO

Page 10: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

• SCHEDA INTEGRATA SIT 14064.1208.0SCHEDA INTEGRATA SIT 14064.1208.0

• FUNZIONI NORMALIFUNZIONI NORMALI– MODULAZIONE IN SANITARIOMODULAZIONE IN SANITARIO– MODULAZIONE RISCALDAMENTOMODULAZIONE RISCALDAMENTO– VERIFICA PRESSIONE DI CARICO VERIFICA PRESSIONE DI CARICO

(TRASDUTTORE DI PRESSIONE)(TRASDUTTORE DI PRESSIONE)– GESTIONE GUASTO SONDE GESTIONE GUASTO SONDE – FUNZIONE ANTIGELO E 24 hFUNZIONE ANTIGELO E 24 h– GESTIONE SONDA ESTERNAGESTIONE SONDA ESTERNA

SCHEDA COMANDOSCHEDA COMANDO

• FUNZIONI PARTICOLARIFUNZIONI PARTICOLARI– GESTIONE VELOCITA’ POMPA; GESTIONE VELOCITA’ POMPA; – GESTIONE VALVOLA DI ZONA GESTIONE VALVOLA DI ZONA – PRERISCALDO CON PROGRAMMAZIONE ORARIAPRERISCALDO CON PROGRAMMAZIONE ORARIA– VISUALIZZAZIONE INFO SOLARE VISUALIZZAZIONE INFO SOLARE – SCADENZA MANUTENZIONESCADENZA MANUTENZIONE

Page 11: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

• COMPITOCOMPITO– PERMETTE DI MANTENERE COSTANTE LA TEMPERATURA IN MANDATA; PERMETTE DI MANTENERE COSTANTE LA TEMPERATURA IN MANDATA;

LA VARIAZIONE DI POTENZA AL BRUCIATORE E’ DATA DAL VARIARE LA VARIAZIONE DI POTENZA AL BRUCIATORE E’ DATA DAL VARIARE DEL NUMERO DI GIRI DEL VENTILATOREDEL NUMERO DI GIRI DEL VENTILATORE

• CARATTERISTICHECARATTERISTICHE– CONTROLLO DELLA TEMPERATURA ATTRAVERSO NTC PRIMARIO DI CONTROLLO DELLA TEMPERATURA ATTRAVERSO NTC PRIMARIO DI

MANDATAMANDATA– RAMPA DI SALITA FIAMMA: RAMPA DI SALITA FIAMMA:

– NEI PRIMI 2 MINUTI DOPO LA RICHIESTA LA FIAMMA RIMANE NEI PRIMI 2 MINUTI DOPO LA RICHIESTA LA FIAMMA RIMANE SEMPRE AL MINIMOSEMPRE AL MINIMO

– IN QUESTO PERIODO VIENE VERIFICATO L’AUMENTO DELLA IN QUESTO PERIODO VIENE VERIFICATO L’AUMENTO DELLA TEMPERATURA:SE L’AUMENTO E’ MINORE DI 5°C/MINUTO LA TEMPERATURA:SE L’AUMENTO E’ MINORE DI 5°C/MINUTO LA FIAMMA VIENE IMPOSTATA PER UN INCREMENTO DI 1° C OGNI 10 FIAMMA VIENE IMPOSTATA PER UN INCREMENTO DI 1° C OGNI 10 sec. (NTC DI MANDATA)sec. (NTC DI MANDATA)

– LA RAMPA DI SALITA SI INTERROMPE NON APPENA RAGGIUNTO IL LA RAMPA DI SALITA SI INTERROMPE NON APPENA RAGGIUNTO IL VALORE IMPOSTATO/CALCOLATOVALORE IMPOSTATO/CALCOLATO

– IL BRUCIATORE SI SPEGNE AL SUPERAMENTO IL BRUCIATORE SI SPEGNE AL SUPERAMENTO DEL SET IMPOSTATO; DEL SET IMPOSTATO;

– NEL TEMPO DI SPEGNIMENTO (NEL TEMPO DI SPEGNIMENTO (P10P10) IL DISPLAY INDICA) IL DISPLAY INDICA

MODULAZIONE RISCALDAMENTOMODULAZIONE RISCALDAMENTO

DISPLAY DISPLAY

MEDIUMMEDIUM

DISPLAY TOPDISPLAY TOP

Page 12: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

MODULAZIONE RISCALDAMENTO MODULAZIONE RISCALDAMENTO CON SONDA ESTERNACON SONDA ESTERNA

• COMPITOCOMPITO– FAR LAVORARE L’IMPIANTO ALLA TEMPERATURA PIU’ INDICATA IN BASE ALLA FAR LAVORARE L’IMPIANTO ALLA TEMPERATURA PIU’ INDICATA IN BASE ALLA

TEMPERATURA ESTERNA, MIGLIORANDO IL RENDIMNETO DI CALDAIA ED IMPIANTOTEMPERATURA ESTERNA, MIGLIORANDO IL RENDIMNETO DI CALDAIA ED IMPIANTO

• CARATTERISTICHECARATTERISTICHE– CONTROLLO DELLA TEMPERATURA ESTERNA TRAMITE SONDA ESTERNACONTROLLO DELLA TEMPERATURA ESTERNA TRAMITE SONDA ESTERNA

– OBBLIGATORIO IMPOSTARE IL COEFFICIENTE K OBBLIGATORIO IMPOSTARE IL COEFFICIENTE K (P15)(P15) PER RELAZIONARE LA PER RELAZIONARE LA TEMPERATURA DI MANDATA CON LA TEMPERATURA ESTERNA IN BASE ALLA ZONA TEMPERATURA DI MANDATA CON LA TEMPERATURA ESTERNA IN BASE ALLA ZONA CLIMATICA ED AL TIPO DI IMPIANTOCLIMATICA ED AL TIPO DI IMPIANTO

• PARAMETRI IMPOSTABILIPARAMETRI IMPOSTABILI

– P15P15 E’ IMPOSTABILE DA 01 A 60: E’ IMPOSTABILE DA 01 A 60:– (01 >>> K =0,1)(01 >>> K =0,1)– (60 >>> K =6,0)(60 >>> K =6,0)

– P7P7 MANDATA MASSIMA (45-85°) MANDATA MASSIMA (45-85°)

– P27 P27 MANDATA MINIMA (25-45°)MANDATA MINIMA (25-45°)– TRAMITE I TASTI SELEZIONE TEMP. TRAMITE I TASTI SELEZIONE TEMP.

MANDATA E’ POSSIBILE ALZARE O MANDATA E’ POSSIBILE ALZARE O ABBASSARE LA CURVA DI 15°CABBASSARE LA CURVA DI 15°C

P7 (45-85°)

P27 (25-45°)

Nel grafico in figura si vede l’effetto che ha l’impostazione dei parametri P15=2 P7=70 P27=35 sulla temperatura di mandata evidenziata in rosso

Page 13: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

MODULAZIONE SANITARIOMODULAZIONE SANITARIO

• COMPITOCOMPITO– MANTENERE COSTANTE LA TEMPERATURA DI MANTENERE COSTANTE LA TEMPERATURA DI

ACQUA CALDA SANITARIA ACQUA CALDA SANITARIA – IL CONFRONTO TRA LA TEMPERATURA LETTA IL CONFRONTO TRA LA TEMPERATURA LETTA

DA NTC E SET IMPOSTATO PORTA ALLA DA NTC E SET IMPOSTATO PORTA ALLA VARIAZIONE DEL NUMERO DI GIRI DEL VARIAZIONE DEL NUMERO DI GIRI DEL VENTILATOREVENTILATORE

• CARATTERISTICHECARATTERISTICHE– DUE MODALITA’ DI FUNZIONAMENTO DUE MODALITA’ DI FUNZIONAMENTO

DISTINTE:DISTINTE:

–P17P17=00 MODALITA’ MORMALE: AL =00 MODALITA’ MORMALE: AL RAGGIUNGIMENTO DEL SET SANITARIO RAGGIUNGIMENTO DEL SET SANITARIO IMPOSTATO IL BRUCIATORE SI PONE ALLA IMPOSTATO IL BRUCIATORE SI PONE ALLA MINIMA POTENZA E RIMANE ACCESO FINO MINIMA POTENZA E RIMANE ACCESO FINO A TEMPERATURA ACS = 65° CA TEMPERATURA ACS = 65° C

–P17P17=01 MODALITA’ ABBINAMENTO =01 MODALITA’ ABBINAMENTO SOLARE: AL RAGGIUNGIMENTO DEL SET SOLARE: AL RAGGIUNGIMENTO DEL SET SANITARIO IMPOSTATO + 5°C IL SANITARIO IMPOSTATO + 5°C IL BRUCIATORE SI SPEGNE (IDEALE PER BRUCIATORE SI SPEGNE (IDEALE PER ABBINAMENTO TRA CALDAIA ISTANTANEA ABBINAMENTO TRA CALDAIA ISTANTANEA E SISTEMA SOLARE A CIRCOLAZIONE E SISTEMA SOLARE A CIRCOLAZIONE NATURALENATURALE

– IN AMBO I CASI SE IN AMBO I CASI SE NTC RNTC R > 90° IL > 90° IL BRUCIATORE VIENE SPENTO ED IL DISPLAY BRUCIATORE VIENE SPENTO ED IL DISPLAY

INDICA INDICA L01L01

ESEMPIO DI ABBINAMENTO TRA ESEMPIO DI ABBINAMENTO TRA SISTEMA SOLARE A CIRCOLAZIONE SISTEMA SOLARE A CIRCOLAZIONE NATURALE E CALDAIA ISTANTANEANATURALE E CALDAIA ISTANTANEA

Page 14: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

FUNZIONE PRERISCALDO 3 STELLE FUNZIONE PRERISCALDO 3 STELLE

• COMPITOCOMPITO– DIMINUIRE IL CONSUMO D’ ACQUA DIMINUIRE IL CONSUMO D’ ACQUA

SANITARIA MANTENENDO IN SANITARIA MANTENENDO IN TEMPERATURA ILCIRCUITO PRIMARIO TEMPERATURA ILCIRCUITO PRIMARIO DELLA CALDAIADELLA CALDAIA

• CARATTERISTICHECARATTERISTICHE– LA FUNZIONE SI ATTIVA PREMENDO IL LA FUNZIONE SI ATTIVA PREMENDO IL

TASTO APPOSITOTASTO APPOSITO– IL SET SANITARIO DEFINISCE LE IL SET SANITARIO DEFINISCE LE

TEMPERATURE ON ed OFF DELLA TEMPERATURE ON ed OFF DELLA FUNZIONE (APPROSSIMATIVAMENTE FUNZIONE (APPROSSIMATIVAMENTE COME IN FIGURA)COME IN FIGURA)

– IL BRUCIATORE SI ACCENDE SE:IL BRUCIATORE SI ACCENDE SE:• SE SE NTC RNTC R <PR ON (vedi grafico) <PR ON (vedi grafico)• DOPO 55 MIN DALL’ULTIMA DOPO 55 MIN DALL’ULTIMA

ACCENSIONE PER PRERISCALDOACCENSIONE PER PRERISCALDO– IL BRUCIATORE SI SPEGNE QUANDO:IL BRUCIATORE SI SPEGNE QUANDO:

• NTC RNTC R >PR OFF >PR OFF• DOPO 90 sec DALL’ACCENSIONEDOPO 90 sec DALL’ACCENSIONE

– DURANTE LA FUNZIONE PRERISCALDO DURANTE LA FUNZIONE PRERISCALDO IL BRUCIATORE RIMANE SEMPRE AL IL BRUCIATORE RIMANE SEMPRE AL MINIMOMINIMO

– FUNZIONE ATTIVABILE ANCHE CON FUNZIONE ATTIVABILE ANCHE CON FASCE ORARIEFASCE ORARIE

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

50

60

SET SAN

ON

OFF

PR ON

PR OFF

SET

40

45

55

TEMP. RISC.TEMP. RISC.

SET SAN.SET SAN.

Page 15: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

SISTEMA ANTIGELOSISTEMA ANTIGELO

• COMPITOCOMPITO– PROTEGGE LA CALDAIA IN CASO DI BASSE TEMPERATURE PROTEGGE LA CALDAIA IN CASO DI BASSE TEMPERATURE

• DATIDATI– ON 6 °C --- OFF 15° C ON 6 °C --- OFF 15° C

– CONTROLLO TEMPERATURA ATTRAVERSO LA SONDA CONTROLLO TEMPERATURA ATTRAVERSO LA SONDA NTC RNTC R– IL BRUCIATORE VIENE ACCESO ALLA MINIMA POTENZA, IL BRUCIATORE VIENE ACCESO ALLA MINIMA POTENZA,

VALVOLA TRE VIE IN SANIATRIOVALVOLA TRE VIE IN SANIATRIO

FUNZIONE “VENTIQUATTRORE”FUNZIONE “VENTIQUATTRORE”

• COMPITOCOMPITO– EVITA CHE IL CIRCOLATORE SI BLOCCHI NEL CASO LA CALDAIA RESTI EVITA CHE IL CIRCOLATORE SI BLOCCHI NEL CASO LA CALDAIA RESTI

INATTIVA PER LUNGHI PERIODIINATTIVA PER LUNGHI PERIODI• DATIDATI

– ON QUANDO LA CALDAIA RESTA INATTIVA PER PIU’ DI 24 OREON QUANDO LA CALDAIA RESTA INATTIVA PER PIU’ DI 24 ORE– I CIRCOLATORI VENGONO ALIMENTATI PER 30 SECONDII CIRCOLATORI VENGONO ALIMENTATI PER 30 SECONDI

DISPLAY DISPLAY

MEDIUMMEDIUM

DISPLAY TOPDISPLAY TOP

Page 16: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

GESTIONE GUASTO SONDE GESTIONE GUASTO SONDE

• GUASTO SONDE RISCALDAMENTOGUASTO SONDE RISCALDAMENTO

– ANOMALIA TRAMITE DISPLAY: ANOMALIA TRAMITE DISPLAY: E06E06 + + (sonda (sonda mandata)mandata)

– ANOMALIA TRAMITE DISPLAY: ANOMALIA TRAMITE DISPLAY: E12E12 + + (sonda (sonda ritorno)ritorno)

– UN GUASTO ALLE SONDE RISCALDAMENTO IMPEDISCE UN GUASTO ALLE SONDE RISCALDAMENTO IMPEDISCE QUALUNQUE ACCENSIONE DEL BRUCIATORE; QUALUNQUE ACCENSIONE DEL BRUCIATORE;

• GUASTO SONDA SANITARIOGUASTO SONDA SANITARIO

– ANOMALIA TRAMITE DISPLAY: ANOMALIA TRAMITE DISPLAY: E07E07 + + – UN GUASTO ALLA SONDA SANITARIA (CORTO CIRCUITO O UN GUASTO ALLA SONDA SANITARIA (CORTO CIRCUITO O

INTERROTTA) NON IMPEDISCE NESSUNA FUNZIONE;INTERROTTA) NON IMPEDISCE NESSUNA FUNZIONE;• GUASTO SONDA ESTERNAGUASTO SONDA ESTERNA

– ANOMALIA TRAMITE DISPLAY: ANOMALIA TRAMITE DISPLAY: E08E08 + +– UN GUASTO ALLA SONDA ESTERNA NON IMPEDISCE UN GUASTO ALLA SONDA ESTERNA NON IMPEDISCE

NESSUNA FUNZIONE MA E’ ESCLUSA LA FUNZIONE NESSUNA FUNZIONE MA E’ ESCLUSA LA FUNZIONE TEMPERATURA SCORREVOLE;TEMPERATURA SCORREVOLE;

• GUASTO SONDA FUMIGUASTO SONDA FUMI

– ANOMALIA TRAMITE DISPLAY: ANOMALIA TRAMITE DISPLAY: E09E09 + +– UN GUASTO ALLA SONDA FUMI IMPEDISCE QUALUNQUE UN GUASTO ALLA SONDA FUMI IMPEDISCE QUALUNQUE

ACCENSIONE DEL BRUCIATORE;ACCENSIONE DEL BRUCIATORE;

Page 17: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

GESTIONE TRASDUTTORE DI PRESSIONE GESTIONE TRASDUTTORE DI PRESSIONE • COMPITOCOMPITO

– VERIFICARE LA CORRETTA PRESSIONE DEL VERIFICARE LA CORRETTA PRESSIONE DEL CIRCUITO PRIMARIOCIRCUITO PRIMARIO

• CARATTERISTICHECARATTERISTICHE– ALIMENTATO A 5 VccALIMENTATO A 5 Vcc– IL VALORE DELLA PRESSIONE VIENE RICAVATO IL VALORE DELLA PRESSIONE VIENE RICAVATO

IN BASE ALLA CADUTA DI TENSIONE (COME IN BASE ALLA CADUTA DI TENSIONE (COME NTC)NTC)

– IN BASE ALLA PRESSIONE LETTA SI POSSONO IN BASE ALLA PRESSIONE LETTA SI POSSONO AVERE 4 SITUAZIONI DIVERSE COME DA AVERE 4 SITUAZIONI DIVERSE COME DA TABELLATABELLA

BARBAR DISPLAY DISPLAY MEDIUMMEDIUM

DISPLAY DISPLAY TOPTOP

LIVELLOLIVELLO BRUCIATOREBRUCIATORE

P > 2,8P > 2,8 ------ TROPPO ALTATROPPO ALTA LIMITATO ALLA POTENZA LIMITATO ALLA POTENZA MINIMAMINIMA

1,0 < P < 1,0 < P < 2,82,8

------ NORMALENORMALE FUNZIONAMENTO FUNZIONAMENTO NORMALENORMALE

0,25 < P < 0,25 < P < 0,80,8

RICHIESTA RICHIESTA RIEMPIMENTORIEMPIMENTO

FUNZIONAMENTO FUNZIONAMENTO NORMALENORMALE

0 < P < 0,250 < P < 0,25 E04E04 +E04+E04

OBBLIGO OBBLIGO RIEMPIMENTORIEMPIMENTO

BLOCCO PER MANCANZA BLOCCO PER MANCANZA ACQUAACQUA

Page 18: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

VERIFICA CIRCOLAZIONE ACQUA VERIFICA CIRCOLAZIONE ACQUA

• COMPITOCOMPITO– VERIFICARE LA SUFFICIENTE PORTATA VERIFICARE LA SUFFICIENTE PORTATA

D’ACQUA NELLO SCAMBIATORE PRIMARIOD’ACQUA NELLO SCAMBIATORE PRIMARIO• CARATTERISTICHECARATTERISTICHE

– QUESTA VERIFCA VIENE ESEGUITA QUESTA VERIFCA VIENE ESEGUITA REGISTRANDO LA VARIAZIONE DI REGISTRANDO LA VARIAZIONE DI TEMPERATRA SUL TEMPERATRA SUL NTC RNTC R

– LIMITE MAX INCREMENTO = 4 °C AL LIMITE MAX INCREMENTO = 4 °C AL SECONDOSECONDO

– SE QUESTO LIMITE VIENE SUPERATO:SE QUESTO LIMITE VIENE SUPERATO:

• INDICAZIONE DISPLAY INDICAZIONE DISPLAY E14E14 + +• POMPA E BRUCIATORE SPENTI PER 1 minPOMPA E BRUCIATORE SPENTI PER 1 min• TENTATIVO DI RIACCENSIONE DOPO 1 TENTATIVO DI RIACCENSIONE DOPO 1

minmin

Page 19: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

GESTIONE CIRCOLATOREGESTIONE CIRCOLATORE• COMPITOCOMPITO

– GESTIRE L’ALIMENTAZIONE ALLA POMPA IN BASE ALLO STATO DELLA CALDAIAGESTIRE L’ALIMENTAZIONE ALLA POMPA IN BASE ALLO STATO DELLA CALDAIA• DATIDATI

– E’ SEMPRE IL PRIMO COMPONENTE CHE VIENE ALIMENTATO A FRONTE DI UNA QUALUNQUE RICHIESTAE’ SEMPRE IL PRIMO COMPONENTE CHE VIENE ALIMENTATO A FRONTE DI UNA QUALUNQUE RICHIESTA– PUO’ ESSERE BLOCCATO DA:PUO’ ESSERE BLOCCATO DA:

• SEGNALE DI PRESSIONE CALDAIA TROPPO BASSA SEGNALE DI PRESSIONE CALDAIA TROPPO BASSA

• SCARSA CIRCOLAZIONE D’ACQUA (INCREMENTO TEMP SU SCARSA CIRCOLAZIONE D’ACQUA (INCREMENTO TEMP SU NTC RNTC R > 4° C/sec) > 4° C/sec)– POST CIRCOLAZIONE DIFFERENZIATA:POST CIRCOLAZIONE DIFFERENZIATA:

• DOPO RICHIESTA SANITARIO: 30 sec (NON MODIFICABILE)DOPO RICHIESTA SANITARIO: 30 sec (NON MODIFICABILE)

• DOPO RICHIESTA RISCALDAMENTO: 1 min (DEFAULT) (MODIFICABILE : DOPO RICHIESTA RISCALDAMENTO: 1 min (DEFAULT) (MODIFICABILE : P11P11= 0 -- 0 sec; = 0 -- 0 sec; P11P11=99 -- 10 min)=99 -- 10 min)– GESTIONE VELOCITA’ (solo INOVIA COND M260T):GESTIONE VELOCITA’ (solo INOVIA COND M260T):

• CON PARAMETRO CON PARAMETRO P03P03=02 GESTIONE AUTOMATICA (DEFAULT):=02 GESTIONE AUTOMATICA (DEFAULT):– RISCALDAMENTO E SANITARIO: VELOCITA’ MASSIMARISCALDAMENTO E SANITARIO: VELOCITA’ MASSIMA– POST CIRCOLAZIONI, ANTIGELO E PRERISCALDO: VELOCITA’ MINIMAPOST CIRCOLAZIONI, ANTIGELO E PRERISCALDO: VELOCITA’ MINIMA

• CON PARAMETRO CON PARAMETRO P03P03=00 SEMPRE MASSIMA VELOCITA’=00 SEMPRE MASSIMA VELOCITA’

• CON PARAMETRO CON PARAMETRO P03P03=01 SEMPRE’ MINIMA VELOCITA’=01 SEMPRE’ MINIMA VELOCITA’

DISPLAY DISPLAY

MEDIUMMEDIUM

Page 20: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

• COMPITOCOMPITO– VERIFICARE LA CORRETTA FUNZIONALITA’ DEL VENTILATOREVERIFICARE LA CORRETTA FUNZIONALITA’ DEL VENTILATORE

• CARATTERISTICHECARATTERISTICHE– LA SCHEDA INTEGRATA GENERA UN SEGNALE PWM IN BASE LA SCHEDA INTEGRATA GENERA UN SEGNALE PWM IN BASE

ALLA POTENZA TERMICA RICHIESTA; QUESTO SEGNALE ALLA POTENZA TERMICA RICHIESTA; QUESTO SEGNALE CORRISPONDE AL “NUMERO DI GIRI RICHIESTO”CORRISPONDE AL “NUMERO DI GIRI RICHIESTO”

– IL VENTILATORE SI “AUTOVERIFICA” E COMUNICA ALLA IL VENTILATORE SI “AUTOVERIFICA” E COMUNICA ALLA SCHEDA IL NUMERO DI GIRI EFFETTIVAMENTE EFFETTUATO SCHEDA IL NUMERO DI GIRI EFFETTIVAMENTE EFFETTUATO (EFFETTO HALL)(EFFETTO HALL)

– SE IL NUMERO DI GIRI EFFETTUATO DIFFERISCE DA QUELLO SE IL NUMERO DI GIRI EFFETTUATO DIFFERISCE DA QUELLO RICHIESTO:RICHIESTO:

• BRUCIATORE OFFBRUCIATORE OFF

• DISPLAY DISPLAY E05E05 + +• VENTILATORE OFFVENTILATORE OFF

– POST VENTILAZIONE: DOPO OGNI ACCENSIONE DEL POST VENTILAZIONE: DOPO OGNI ACCENSIONE DEL BRUCIATORE IL VENTILATORE RESTA ALIMENTATO PER 30 secBRUCIATORE IL VENTILATORE RESTA ALIMENTATO PER 30 sec

CONTROLLO E GESTIONE VENTILATORECONTROLLO E GESTIONE VENTILATORE

ALIM. 220 V ALIM. 220 V CACA

SEGNALE CONTROLLO SEGNALE CONTROLLO NUMERO DI GIRINUMERO DI GIRI

Page 21: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

• COMPITO:COMPITO:– FUNZIONE CHE PERMETTE DI RIPETERE AUTOMATICAMENTE FINO A 3 FUNZIONE CHE PERMETTE DI RIPETERE AUTOMATICAMENTE FINO A 3

TENTATIVI DI RIACCENSIONE DEL BRUCIATORETENTATIVI DI RIACCENSIONE DEL BRUCIATORE• DATI:DATI:

– SE PER UN QUALUNQUE MOTIVO IL BRUCIATORE NON RIESCE AD SE PER UN QUALUNQUE MOTIVO IL BRUCIATORE NON RIESCE AD ACCENDERSI (MANCATA ACCENSIONE) LA SCHEDA RIPETE FINO 3 ACCENDERSI (MANCATA ACCENSIONE) LA SCHEDA RIPETE FINO 3 TENTATIVI RITARDATI DI 30 sec TEMPO NEL QUALE RIMANE ATTIVO IL TENTATIVI RITARDATI DI 30 sec TEMPO NEL QUALE RIMANE ATTIVO IL VENTILATORE (FUNZIONE PULIZIA CAMERA DI COMBUSTIONE); VENTILATORE (FUNZIONE PULIZIA CAMERA DI COMBUSTIONE);

– LA RILEVAZIONE FIAMMA NON E’ SENSIBILE ALL’INVERSIONE FASE-LA RILEVAZIONE FIAMMA NON E’ SENSIBILE ALL’INVERSIONE FASE-NEUTRO; NEUTRO;

– SE SBAGLIA ANCHE IL TERZO TENTATIVO INDICAZIONE DISPLAY: SE SBAGLIA ANCHE IL TERZO TENTATIVO INDICAZIONE DISPLAY: E01E01

TENTATIVI MULTIPLI DI RIACCENSIONETENTATIVI MULTIPLI DI RIACCENSIONE

Page 22: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

POTENZA UTILE RISCALDAMENTOPOTENZA UTILE RISCALDAMENTO

16/16SV16/16SV 100100 17,1017,10 6,506,50

0000 6,506,50 6,506,50

20/25SV20/25SV 7474 21,2021,20 6,506,50

0000 6,506,50 6,506,50

30/35SV30/35SV 8484 32,1032,10 9,209,20

0000 9,209,20 9,209,20

• COMPITOCOMPITO– ADATTARE LA MASSIMA POTENZA DEL BRUCIATORE IN BASE ALLA DIMENSIONE ADATTARE LA MASSIMA POTENZA DEL BRUCIATORE IN BASE ALLA DIMENSIONE

DELL’IMPIANTO TERMICO SENZA VARIARE LA POTENZA MINIMA O LA POTENZA IN DELL’IMPIANTO TERMICO SENZA VARIARE LA POTENZA MINIMA O LA POTENZA IN SANITARIO (ANCHE PER VERSIONE SV)SANITARIO (ANCHE PER VERSIONE SV)

– TRAMITE IL TRAMITE IL P12P12 E’ POSSIBILE SELEZIONARE LA POTENZA MASSIMA PIU’ INDICATA: IL E’ POSSIBILE SELEZIONARE LA POTENZA MASSIMA PIU’ INDICATA: IL CAMPO DI MODULAZIONE PUO’ VARIARE COME DA TEBELLACAMPO DI MODULAZIONE PUO’ VARIARE COME DA TEBELLA

PotenzaPotenza Pr 12Pr 12 P. Max P. Max (50/30°c)

P. Min P. Min (50/30°C)(50/30°C)

20/25SM20/25SM 74**74** 21,2021,20 6,506,50

0000 6,506,50 6,506,50

30/35SM30/35SM 84**84** 32,1032,10 9,209,20

0000 9,29,2 9,209,20

Page 23: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

REGOLAZIONE DATA E ORA (solo INOVIA COND)REGOLAZIONE DATA E ORA (solo INOVIA COND)

SU QUESTA SCHEDA E’ POSSIBILE IMPOSTARE ORA E DATA CHE SERVONO SIA PER IMPOSTARE LE FASCE ORARIE DEL SU QUESTA SCHEDA E’ POSSIBILE IMPOSTARE ORA E DATA CHE SERVONO SIA PER IMPOSTARE LE FASCE ORARIE DEL PRERISCALDO CHE PER LA FUNZIONE “SCADENA MANUTENZIONE”PRERISCALDO CHE PER LA FUNZIONE “SCADENA MANUTENZIONE”

• IMPOSTAZIONE OROLOGIOIMPOSTAZIONE OROLOGIO

– TENERE PREMUTO PER CIRCA 5 sec IL TASTOTENERE PREMUTO PER CIRCA 5 sec IL TASTO L L – CON I TASTI CON I TASTI AA e e BB SI CAMBIA IL VALORE SI CAMBIA IL VALORE

– CON IL TASTO CON IL TASTO LL SI MEMORIZZA LA MODIFICA SI MEMORIZZA LA MODIFICA

– CON I TASTI CON I TASTI GG e e HH SI PASSA DI PARAMETRO SI PASSA DI PARAMETRO

– CON IL TASTO CON IL TASTO LL SI SALVANO LE MODIFICHE SI SALVANO LE MODIFICHE

– TENENDO PREMUTO TENENDO PREMUTO LL PER 5 sec SI ESCE DALLA PROGRAMMAZIONE PER 5 sec SI ESCE DALLA PROGRAMMAZIONE

Page 24: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

FASCIE ORARIE PRERISCALDO (solo INOVIA COND)FASCIE ORARIE PRERISCALDO (solo INOVIA COND)• COMPITOCOMPITO

– PROGRAMMARE LA FUNZIONE PRERISCALDO IN BASE ALLE REALI ESIGENZE DELL’UTENTEPROGRAMMARE LA FUNZIONE PRERISCALDO IN BASE ALLE REALI ESIGENZE DELL’UTENTE• IMPOSTAZIONE FASCIE ORARIE PRERISCALDOIMPOSTAZIONE FASCIE ORARIE PRERISCALDO

1.1. TENERE PREMUTO PER 5 sec I TASTI TENERE PREMUTO PER 5 sec I TASTI LL e e HH

2.2. IL DISPLAY INDICA IL DISPLAY INDICA P1ONP1ON (PRIMO ORARIO DI ATTIVAZIONE) (PRIMO ORARIO DI ATTIVAZIONE)

3.3. CON IL TASTO CON IL TASTO DD SI ENTRA IN MODIFICA DI SI ENTRA IN MODIFICA DI P1ONP1ON

4.4. CON I TASTI CON I TASTI AA e e BB SI IMPOSTA L’ORARIO DESIDERATO SI IMPOSTA L’ORARIO DESIDERATO

5.5. CON IL TASTO CON IL TASTO LL SI MEMORIZZA LA MODIFICA SI MEMORIZZA LA MODIFICA

6.6. CON IL TASTO CON IL TASTO HH SI ESCE DALLA MODIFICA SI ESCE DALLA MODIFICA

7.7. CON I TASTI CON I TASTI GG e e HH SI AVANZA DI PARAMETRO SI AVANZA DI PARAMETRO

8.8. IL DISPLAY INDICA IL DISPLAY INDICA P01OFP01OF (TERMINE PRIMA FASCIA ORARIA) (TERMINE PRIMA FASCIA ORARIA)

9.9. RIPETERE LE OPERAZIONI DAL PUNTO 3RIPETERE LE OPERAZIONI DAL PUNTO 3

10.10. LE FASCIE ORARIE NON UTILIZZATE IMPOSTARE A 00:00LE FASCIE ORARIE NON UTILIZZATE IMPOSTARE A 00:00

11.11. CON IL TASTO CON IL TASTO F F ATTIVARE LA FUNZIONE PRERISCALDOATTIVARE LA FUNZIONE PRERISCALDO

SE TUTTO CORRETTO IL DISPLAY VISUALIZZA LE DUE ICONE EVIDENZIATE IN FIGURASE TUTTO CORRETTO IL DISPLAY VISUALIZZA LE DUE ICONE EVIDENZIATE IN FIGURA

Page 25: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

INTEGRAZIONE SOLAREINTEGRAZIONE SOLARE

• COMPITOCOMPITO– METTERE IN COMUNICAZIONE CENTRALINA SOLARE E SCHEDA METTERE IN COMUNICAZIONE CENTRALINA SOLARE E SCHEDA

COMANDO CALDAIA PER VISUALIZZARE L’APPORTO DEL PANNELLO COMANDO CALDAIA PER VISUALIZZARE L’APPORTO DEL PANNELLO SOLARE SOLARE

• COLLEGAMENTO ELETTRICO ED INDICAZIONI DISPLAY CALDAIA COLLEGAMENTO ELETTRICO ED INDICAZIONI DISPLAY CALDAIA – CENTRALINA SOLARE E CALDAIA COMUNICANO ATTRAVERSO LA LINEA COMANDO REMOTO (OT)CENTRALINA SOLARE E CALDAIA COMUNICANO ATTRAVERSO LA LINEA COMANDO REMOTO (OT)– ATTRAVERSO APPOSITA ICONA SUL PANNELLO COMANDI CALDAIA VIENE INDICATO SIA IL ATTRAVERSO APPOSITA ICONA SUL PANNELLO COMANDI CALDAIA VIENE INDICATO SIA IL

COLLEGAMENTO CHE L’EFFETTIVA INTEGRAZIONE DISTINTA NEL CASO CHE CI SIA O MENO COLLEGAMENTO CHE L’EFFETTIVA INTEGRAZIONE DISTINTA NEL CASO CHE CI SIA O MENO PRELIEVO PRELIEVO

SIMBOLO PRESENTE:COLLEGAMENTO ATTIVOSIMBOLO PRESENTE:COLLEGAMENTO ATTIVO

SIMBOLO LAMPEGGIANTE: POMPA SOLARE ATTIVASIMBOLO LAMPEGGIANTE: POMPA SOLARE ATTIVA

REMOTOREMOTO

Page 26: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

INTEGRAZIONE SOLAREINTEGRAZIONE SOLARE

• COLLEGAMENTO IDRAULICO ED INDICAZIONI DISPLAY COLLEGAMENTO IDRAULICO ED INDICAZIONI DISPLAY – CALDAIA MISTA – COLLEGAMENTO SOLO CIRCUITO SANITARIOCALDAIA MISTA – COLLEGAMENTO SOLO CIRCUITO SANITARIO

• CONSIGLIATA L’INSTALLAZIONE DI VALVOLA MISCELATRICE/DEVIATRICE CHE IN BASE ALLA TEMPERATURA DELL’ACQUA IN CONSIGLIATA L’INSTALLAZIONE DI VALVOLA MISCELATRICE/DEVIATRICE CHE IN BASE ALLA TEMPERATURA DELL’ACQUA IN USCITA DAL BOLLITORE DEVIA O VERSO L’INGRESSO ACQUA FREDDA CALDAIA O DIRETTAMENTE ALL’UTENZAUSCITA DAL BOLLITORE DEVIA O VERSO L’INGRESSO ACQUA FREDDA CALDAIA O DIRETTAMENTE ALL’UTENZA

• LA CENTRALINA SOLARE COMUNICA IL VALORE DI S1 (vedi schema) ALLA CALDAIA CHE VISUALIZZERA’ IL LIVELLO DI LA CENTRALINA SOLARE COMUNICA IL VALORE DI S1 (vedi schema) ALLA CALDAIA CHE VISUALIZZERA’ IL LIVELLO DI INTEGRAZIONE COME DA TABELLAINTEGRAZIONE COME DA TABELLA

TEMPERATURA TEMPERATURA BOLLITORE S1 BOLLITORE S1

(letta dalla (letta dalla centralina)centralina)

NO PRELIEVONO PRELIEVO CON PRELIEVO CON PRELIEVO (lampeggiano solo (lampeggiano solo le lineette)le lineette)

S1 > 70°S1 > 70°

47°<S1<70°47°<S1<70°

36°<S1<47°36°<S1<47°

25°<S1<36°25°<S1<36°

S1<=25S1<=25

Page 27: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

INTEGRAZIONE SOLAREINTEGRAZIONE SOLARE

• COLLEGAMENTO IDRAULICO ED INDICAZIONI DISPLAY COLLEGAMENTO IDRAULICO ED INDICAZIONI DISPLAY – CALDAIA SV – COLLEGAMENTO SOLO CIRCUITO PRIMARIOCALDAIA SV – COLLEGAMENTO SOLO CIRCUITO PRIMARIO

• ATTRAVERSO LA LETTURA DELLA SONDA ATTRAVERSO LA LETTURA DELLA SONDA SBSB LA CALDAIA SI ATTIVA AUTONOMAMENTE PER INTEGRAZIONE BOLLITORE LA CALDAIA SI ATTIVA AUTONOMAMENTE PER INTEGRAZIONE BOLLITORE• LA CENTRALINA SOLARE COMUNICA IL VALORE DI S1 (vedi schema) ALLA CALDAIA CHE VISUALIZZERA’ IL LIVELLO DI LA CENTRALINA SOLARE COMUNICA IL VALORE DI S1 (vedi schema) ALLA CALDAIA CHE VISUALIZZERA’ IL LIVELLO DI

TEMPERATURA DEL BOLLITORE COME DA TABELLATEMPERATURA DEL BOLLITORE COME DA TABELLA

TEMPERATURA TEMPERATURA BOLLITORE S1 BOLLITORE S1

(letta dalla (letta dalla centralina)centralina)

INDICAZIONI INDICAZIONI DISPLAYDISPLAY

S1>70°S1>70°

S1>47°S1>47°

S1>36°S1>36°

S1>25°S1>25°

S1<=25S1<=25

Page 28: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

• COMPITOCOMPITO– IL COMANDI REMOTO, A FRONTE DI UNA RICHIESTA DI CALORE DALL’AMBIENTE, PUO’ COMANDARE L’ACCENSIONE DELLA CALDAIA E L’APERTURA DI UNA VALVOLA DI ZONA IL COMANDI REMOTO, A FRONTE DI UNA RICHIESTA DI CALORE DALL’AMBIENTE, PUO’ COMANDARE L’ACCENSIONE DELLA CALDAIA E L’APERTURA DI UNA VALVOLA DI ZONA

• CARATTERISTICHECARATTERISTICHE

– FUNZIONE ATTIVABILE TRAMITE FUNZIONE ATTIVABILE TRAMITE P04P04 (default 00, non attiva)(default 00, non attiva)– SCHEDA AUSILIARE A RELE’ CON USCITA A 220 VacSCHEDA AUSILIARE A RELE’ CON USCITA A 220 Vac– 3 CONTATTI: N (neutro) – NO (apertura) – NC (chiusura)3 CONTATTI: N (neutro) – NO (apertura) – NC (chiusura)– IN CASO DI IMPIANTO CON PIU’ VALVOLE DI ZONA COLLEGARE I LORO FINE CORSAIN CASO DI IMPIANTO CON PIU’ VALVOLE DI ZONA COLLEGARE I LORO FINE CORSA

SULLA LINEA TA (contatti 1 e 3 in morsettiera).SULLA LINEA TA (contatti 1 e 3 in morsettiera).

IN QUESTO CASO LE TEMPERATURE DI IN QUESTO CASO LE TEMPERATURE DI

MANDATA SONO DIVERSIFICABILI:MANDATA SONO DIVERSIFICABILI:

ZONA REMOTO: SET DA REMOTOZONA REMOTO: SET DA REMOTO

ZONE TA: SET DA PANNELLO COMANDIZONE TA: SET DA PANNELLO COMANDI

CALDAIA CALDAIA

GESTIONE VALVOLA DI ZONA (solo INOVIA COND)GESTIONE VALVOLA DI ZONA (solo INOVIA COND)

– IN CASO DI RICHIESTE CONTEMPORANEE LA IN CASO DI RICHIESTE CONTEMPORANEE LA TEMPERATURA DI MANDATA E’ IN FUNZIONE DI: TEMPERATURA DI MANDATA E’ IN FUNZIONE DI: P04P04 = 01 SET RISC. = 01 SET RISC. + ALTO+ ALTO

P04P04 = 02 SET RISC. + BASSO = 02 SET RISC. + BASSO

Page 29: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

SCADENZA MANUTENZIONESCADENZA MANUTENZIONE

• COMPITOCOMPITO– RICORDARE ALLL’UTENTE FINALE LA SCADENZA DELLA RICORDARE ALLL’UTENTE FINALE LA SCADENZA DELLA

MANUTENZIONEMANUTENZIONE.

• INDICAZIONE DISPLAYINDICAZIONE DISPLAY– LA SEGNALAZIONE COMPARE 2 MESI PRIMA DELL’EFFETTIVA LA SEGNALAZIONE COMPARE 2 MESI PRIMA DELL’EFFETTIVA

SCADENZASCADENZA– LA SEGNALAZIONE NON IMPEDISCE ALCUNA FUNZIONE LA SEGNALAZIONE NON IMPEDISCE ALCUNA FUNZIONE

DELL’APPARECCHIODELL’APPARECCHIO

– IL RESET DEI MESI SI FA TRAMITE IL IL RESET DEI MESI SI FA TRAMITE IL PM 28PM 28

Page 30: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

MANCATA ACCENSIONE BRUCIATOREMANCATA ACCENSIONE BRUCIATORE E01 resetE01 reset

INTERVENTO TERMOSTATO DI SICUREZZA (T>105°C)INTERVENTO TERMOSTATO DI SICUREZZA (T>105°C) E02 resetE02 reset

ALTRI GUASTI ALTRI GUASTI E03 resetE03 reset

MANCANZA ACQUA (PRESSOSTATO ASSOLUTO) MANCANZA ACQUA (PRESSOSTATO ASSOLUTO) E04 resetE04 reset

ANOMALIA CONTROLLO VELOCITA’ VENTILATOREANOMALIA CONTROLLO VELOCITA’ VENTILATORE E05 + E05 +

ANOMALIA SONDA NTC RISCALDAMENTOANOMALIA SONDA NTC RISCALDAMENTO E06 + E06 +

ANOMALIA SONDA NTC SANITARIOANOMALIA SONDA NTC SANITARIO E07 +E07 +

ANOMALIA SONDA ESTERNAANOMALIA SONDA ESTERNA E08 + E08 +

ANOMALIA SONDA NTC FUMI ANOMALIA SONDA NTC FUMI E09 + E09 +

BLOCCO PER TEMPERATURA FUMI ECCESSIVA (T> 120°C)BLOCCO PER TEMPERATURA FUMI ECCESSIVA (T> 120°C) E10 resetE10 reset

ANOMALIA SONDA NTC RISCALDAMENTO RITORNOANOMALIA SONDA NTC RISCALDAMENTO RITORNO E12 + E12 +

DT CICUITO PRIMARIO > 40°DT CICUITO PRIMARIO > 40° E13 +E13 +

ASSENZA DI CIRCOLAZIONE ACQUA (AUMENTO TEMPERATURA > 2K/s) ASSENZA DI CIRCOLAZIONE ACQUA (AUMENTO TEMPERATURA > 2K/s) (RIPRISTINO POSSIBILE SOLO DOPO 10 MINUTI)(RIPRISTINO POSSIBILE SOLO DOPO 10 MINUTI)

E14 +E14 +

ASSENZA DI CIRCOLAZIONE ACQUA CON INTERVENTO TERMOSTATO ASSENZA DI CIRCOLAZIONE ACQUA CON INTERVENTO TERMOSTATO DI SICUREZZA T>105°CDI SICUREZZA T>105°C

E14 resetE14 reset

NON CORRETTO SCAMBIO TERMICO DURANTE PRODUZIONE A.C.S. NON CORRETTO SCAMBIO TERMICO DURANTE PRODUZIONE A.C.S. (TEMPERATURA > 85°C SU CIRCUITO PRIMARIO)(TEMPERATURA > 85°C SU CIRCUITO PRIMARIO)

L01L01

DIAGNOSTICADIAGNOSTICA

Page 31: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLAY – MENU’ INFODISPLAY – MENU’ INFO• COMPITOCOMPITO

– IL MENU’ INFO PERMETTE ESCLUSIVAMENTE LA LETTURA DEI “DATI DI IL MENU’ INFO PERMETTE ESCLUSIVAMENTE LA LETTURA DEI “DATI DI SERVIZIO” DELLA CALDAIA DURANTE IL FUNZIONAMENTOSERVIZIO” DELLA CALDAIA DURANTE IL FUNZIONAMENTO.

• UTILIZZO MENU’ INFOUTILIZZO MENU’ INFO– PER ENTRARE NEL MENU’ INFOPER ENTRARE NEL MENU’ INFO

• TOPTOP: PREMERE IL PULSANTE : PREMERE IL PULSANTE BB FINO A CHE IL DISPLAY NON INDICA FINO A CHE IL DISPLAY NON INDICA J00J00 + + VALORE PARAMETROVALORE PARAMETRO

• MEDIUMMEDIUM: PREMERE C + D FINO A CHE IL DISPLAY NON INDICA : PREMERE C + D FINO A CHE IL DISPLAY NON INDICA d0d0 + + VALORE PARAMETROVALORE PARAMETRO

– PER SCORRERE I PARAMETRI UTILIZZARE I TASTI PER SCORRERE I PARAMETRI UTILIZZARE I TASTI CC o o DD– PER USCIRE DAL MENU’ INFO PREMERE CONTEMPORANEAMENTE I TASTI PER USCIRE DAL MENU’ INFO PREMERE CONTEMPORANEAMENTE I TASTI AA e e DD

AA

CC

DD

BBAA

CC

DD

Page 32: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLAY – MENU INFODISPLAY – MENU INFO

LISTA PARAMETRI DA MENU’ INFOLISTA PARAMETRI DA MENU’ INFO

PRESSIONE CIRCUITO PRIMARIOPRESSIONE CIRCUITO PRIMARIO J00J00

TEMPERATURA ESTERNATEMPERATURA ESTERNA J01J01

COEFFICIENTE K (Sonda esterna)COEFFICIENTE K (Sonda esterna) J02J02

OFFSET (TRASLAZIONE DEL DIAGRAMMA OFFSET (TRASLAZIONE DEL DIAGRAMMA RELATIVO A K ± 15°C)RELATIVO A K ± 15°C)

J03J03

TEMPERATURA RISCALDAMENTO TEMPERATURA RISCALDAMENTO (CALCOLATA)(CALCOLATA)

J04J04

TEMPERATURA MANDATA TEMPERATURA MANDATA RISCALDAMENTO (°C)RISCALDAMENTO (°C)

J05J05

TEMPERATURA RITORNO TEMPERATURA RITORNO RISCALDAMENTO (°C)RISCALDAMENTO (°C)

J06J06

TEMPERATURA SANITARIO (°C)TEMPERATURA SANITARIO (°C) J09J09

PORTATA ACQUA SANITARIA (L/MIN)PORTATA ACQUA SANITARIA (L/MIN) J10J10

TEMPERATURA FUMI (°C)TEMPERATURA FUMI (°C) J11J11

VELOCITA’ VENTILATOREVELOCITA’ VENTILATORE J12J12

VALORE IONIZZAZIONEVALORE IONIZZAZIONE J14J14

MESI MANCANTI ALLA MANUTENZIONEMESI MANCANTI ALLA MANUTENZIONE J15J15

Page 33: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

MENU’ HISTORYMENU’ HISTORY

• COMPITOCOMPITO– LA MODALITA’ HISTORY PERMETTE LA VISUALIZZAZIONE GLI ULTIMI 10 ERRORILA MODALITA’ HISTORY PERMETTE LA VISUALIZZAZIONE GLI ULTIMI 10 ERRORI

• DATIDATI– PER ACCEDERE ALLA MODALITA’ “HISTORY” VEDI IMMAGINI SEGUENTIPER ACCEDERE ALLA MODALITA’ “HISTORY” VEDI IMMAGINI SEGUENTI– NEL DISPLAY COMPARIRA’ IL CODICE DELL’ERRORE ALTERNATO DAL NUMERO NEL DISPLAY COMPARIRA’ IL CODICE DELL’ERRORE ALTERNATO DAL NUMERO

PROGRESSIVO DELL’ERRORE (PROGRESSIVO DELL’ERRORE (H00H00 + + EE - - INDICA L’ULTIMO ERRORE - - INDICA L’ULTIMO ERRORE REGISTRATO) REGISTRATO)

– IL PRIMO ERRORE CHE COMPARIRA’ E’ L’ULTIMO ACCADUTO.IL PRIMO ERRORE CHE COMPARIRA’ E’ L’ULTIMO ACCADUTO.– TRAMITE I TASTI DEL SANITARIO SI POSSONO SCORRERE GLI ULTIMI 10 ERRORI TRAMITE I TASTI DEL SANITARIO SI POSSONO SCORRERE GLI ULTIMI 10 ERRORI

MEMORIZZATI.MEMORIZZATI.

Page 34: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

• COMPITOCOMPITO– SETTARE LA SCHEDA DI RICAMBIO SETTARE LA SCHEDA DI RICAMBIO – ADATTARE LA CALDAIA AL TIPO DI IMPIANTOADATTARE LA CALDAIA AL TIPO DI IMPIANTO

• SCHEDA DI RICAMBIOSCHEDA DI RICAMBIO– APPENA INSTALLATA LA SCHEDA DI RICAMBIO VIENE APPENA INSTALLATA LA SCHEDA DI RICAMBIO VIENE

SEGNALATO SEGNALATO E99E99. . TALE ERRORE SI RESETTA SOLO TALE ERRORE SI RESETTA SOLO IMPOSTANDO IL PARAMETROIMPOSTANDO IL PARAMETRO P01P01

• INGRESSO MENU’ PROGRAMMAZIONE DA PANN. COMANDIINGRESSO MENU’ PROGRAMMAZIONE DA PANN. COMANDI

– TENERE PREMUTO I PULSANTI TENERE PREMUTO I PULSANTI A+B+DA+B+D IN FIGURA (CIRCA 10 IN FIGURA (CIRCA 10

sec): IL DISPLAY INDICHERAsec): IL DISPLAY INDICHERA’’ P01P01 CON IL RELATIVO VALORE CON IL RELATIVO VALORE IMPOSTATOIMPOSTATO

– CON I TASTI CON I TASTI AA e e BB SI SCORRONO I VARI PARAMETRI SI SCORRONO I VARI PARAMETRI

– CON I TASTI CON I TASTI HH e e GG SI MODIFICANO I VALORI IMPOSTATI SI MODIFICANO I VALORI IMPOSTATI

– CON IL TASTO CON IL TASTO DD SI CONFERMA LA MODIFICA SI CONFERMA LA MODIFICA

– TENERE PREMUTO I PULSANTI TENERE PREMUTO I PULSANTI A+B+D A+B+D PER USCIRE DALLA PER USCIRE DALLA PROGRAMMAZIONE OPPURE TOGLIERE ALIMENTAZIONE PROGRAMMAZIONE OPPURE TOGLIERE ALIMENTAZIONE ELETTRICAELETTRICA

INOVIA COND : MENU’ PROGRAMMAZIONEINOVIA COND : MENU’ PROGRAMMAZIONE

DD

A+B+A+B+DD

H o GH o GA o BA o B

Page 35: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

• COMPITOCOMPITO– SETTARE LA SCHEDA DI RICAMBIO SETTARE LA SCHEDA DI RICAMBIO – ADATTARE LA CALDAIA AL TIPO DI IMPIANTOADATTARE LA CALDAIA AL TIPO DI IMPIANTO

• SCHEDA DI RICAMBIOSCHEDA DI RICAMBIO– APPENA INSTALLATA LA SCHEDA DI RICAMBIO VIENE APPENA INSTALLATA LA SCHEDA DI RICAMBIO VIENE

SEGNALTO SEGNALTO E99E99. . TALE ERRORE SI RESETTA SOLO TALE ERRORE SI RESETTA SOLO IMPOSTANDO IL PARAMETROIMPOSTANDO IL PARAMETRO P01P01

• INGRESSO MENU’ PROGRAMMAZIONE DA PANN. INGRESSO MENU’ PROGRAMMAZIONE DA PANN. COMANDICOMANDI

– TENERE PREMUTO I PULSANTI TENERE PREMUTO I PULSANTI 15+16+1715+16+17 PER CIRCA 10 PER CIRCA 10 sec, IL DISPLAY INDICHERA’sec, IL DISPLAY INDICHERA’ ALTERNATIVAMENTE “ALTERNATIVAMENTE “P01P01” e ” e ““0101” ”

– PREMERE CONTEMPORANEAMENTE I TASTI PREMERE CONTEMPORANEAMENTE I TASTI 15 E 1715 E 17 PER PER VEDERE IL VALORE DEL PARAMETRO;VEDERE IL VALORE DEL PARAMETRO;

– MODIFICARE IL VALORE DEL PARAMETRO CON I TASTI MODIFICARE IL VALORE DEL PARAMETRO CON I TASTI 16 E 16 E 17;17;

– CONFERMARE IL VALORE IMPOSTATO CON IL TASTO CONFERMARE IL VALORE IMPOSTATO CON IL TASTO 1515;;– PER SCORRERE I VARI PARAMETRI UTILIZZAREI TASTI PER SCORRERE I VARI PARAMETRI UTILIZZAREI TASTI 16 E 16 E

17;17;– PER USCIRE PREMERE CONTEMPORANEAMENTE I TASTI PER USCIRE PREMERE CONTEMPORANEAMENTE I TASTI 15, 15,

16 E 1716 E 17 OPPURE TOGLIERE ALIMENTAZIONE ELTTRICA OPPURE TOGLIERE ALIMENTAZIONE ELTTRICA

RINNOVA COND : MENU’ PROGRAMMAZIONE RINNOVA COND : MENU’ PROGRAMMAZIONE

Page 36: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI

DISPLADISPLAYY

REMOTREMOTOO

FUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P01P01 TIPO CALDAIA TIPO CALDAIA 0000 : Nessun Modello selezionato => Er 99 : Nessun Modello selezionato => Er 99

0101 : Rinnova Cond 25 S (1°e 2° serie: M160 2025SM) : Rinnova Cond 25 S (1°e 2° serie: M160 2025SM)

0303 : Rinnova Cond 35 S (1°e 2° serie: M160 3035SM) : Rinnova Cond 35 S (1°e 2° serie: M160 3035SM)

10 10 : Rinnova Cond 12 SV (2°serie: M160 1212SV) (con : Rinnova Cond 12 SV (2°serie: M160 1212SV) (con NTC bollitore)NTC bollitore)

1212 : Rinnova Cond 25 SV (1°serie: M160 2525SV) (con : Rinnova Cond 25 SV (1°serie: M160 2525SV) (con NTC bollitore)NTC bollitore)

1313 : Rinnova Cond 30 SV (1° serie: M160 3030SV) : Rinnova Cond 30 SV (1° serie: M160 3030SV) (con NTC bollitore)(con NTC bollitore)

14 14 : Rinnova Cond 12 SV (2°serie: M160 1212SV) (con: Rinnova Cond 12 SV (2°serie: M160 1212SV) (con

termostato bollitore)termostato bollitore)

1616 : Rinnova Cond 25 SV (1° serie: M160 2525SV) : Rinnova Cond 25 SV (1° serie: M160 2525SV) (con termostato bollitore)(con termostato bollitore)

1717 : Rinnova Cond 30 SV (1° serie: M160 3030SV) : Rinnova Cond 30 SV (1° serie: M160 3030SV) (con termostato bollitore)(con termostato bollitore)

2323 : :Rinnova Solar Tank 25 S (T 160 2525) Rinnova Solar Tank 25 S (T 160 2525)

2424 : :Rinnova Solar Tank 35 S (T 160 3035)Rinnova Solar Tank 35 S (T 160 3035)

Page 37: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLADISPLAYY

REMOTREMOTOO

FUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P01P01 TIPO CALDAIA TIPO CALDAIA 2727: : Rinnova Cond 25 SV (2°serie: M160 2025SV) (con Rinnova Cond 25 SV (2°serie: M160 2025SV) (con NTC bollitore)NTC bollitore)

2828: : Rinnova Cond 35 SV (2°serie: M160 3035SV) (con Rinnova Cond 35 SV (2°serie: M160 3035SV) (con NTC bollitore)NTC bollitore)

3030: : Rinnova Cond 25 SV (2°serie: M160 2025SV) (con Rinnova Cond 25 SV (2°serie: M160 2025SV) (con termostato bollitore)termostato bollitore)

3131: : Rinnova Cond 35 SV (2°serie: M160 3035SV) (con Rinnova Cond 35 SV (2°serie: M160 3035SV) (con termostato bollitore)termostato bollitore)

33 :33 : Inovia Cond IN25 S (M261 2025SM) Inovia Cond IN25 S (M261 2025SM)

34 :34 : inovia Cond IN 35 S ( M261 3035SM) inovia Cond IN 35 S ( M261 3035SM)

3535 : Inovia Cond 25 S (M260 2025SM) : Inovia Cond 25 S (M260 2025SM)

3737 : Inovia Cond 35 S (M260 3035SM) : Inovia Cond 35 S (M260 3035SM)

4545 : : Inovia Cond 16 SV (M260 1616SV) (con NTC Inovia Cond 16 SV (M260 1616SV) (con NTC bollitore)bollitore)

4646 : : Inovia Cond 25 SV (M260 2025SV) (con NTC Inovia Cond 25 SV (M260 2025SV) (con NTC bollitore)bollitore)

4747 : : Inovia Cond IN 16 SV (M261 1616SV) (con NTC Inovia Cond IN 16 SV (M261 1616SV) (con NTC bollitore)bollitore)

4848 : : Inovia Cond IN 25 SV (M260 2025SV) (con NTC Inovia Cond IN 25 SV (M260 2025SV) (con NTC bollitore)bollitore)

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI

Page 38: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLADISPLAYY

REMOTREMOTOO

FUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P01P01 TIPO CALDAIA TIPO CALDAIA 4949 :: Inovia Cond 35 SV (M260 3035SV) (con NTC Inovia Cond 35 SV (M260 3035SV) (con NTC bollitore)bollitore)

5151 : : Inovia Cond 16 SV (M260 1616SV) (con termostato Inovia Cond 16 SV (M260 1616SV) (con termostato bollitore)bollitore)

5252 : : Inovia Cond 25 SV (M260 2025SV) (con termostato Inovia Cond 25 SV (M260 2025SV) (con termostato bollitore)bollitore)

5353 : : Inovia Cond IN 16 SV (M261 16SV) (con termostato Inovia Cond IN 16 SV (M261 16SV) (con termostato bollitore)bollitore)

5353 : : Inovia Cond IN 25 SV (M261 25SV) (con termostato Inovia Cond IN 25 SV (M261 25SV) (con termostato bollitore)bollitore)

5555 :: Inovia Cond 35 SV (M260 3035SV) Inovia Cond 35 SV (M260 3035SV) (con termostato (con termostato bollitore)bollitore)

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI

Page 39: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLAYDISPLAY

REMOTOREMOTOFUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P02P02 TIPO SENSORE ACQUATIPO SENSORE ACQUA

TRASDUTTORE FLUSSOSTATOTRASDUTTORE FLUSSOSTATO

PRESSOSTATO FLUSSIMETROPRESSOSTATO FLUSSIMETRO

0000 = PRESSOSTATO + FLUSSOSTATO(M160 = PRESSOSTATO + FLUSSOSTATO(M160 1°serie)1°serie)

0000 = SV CON PRESSOSTATO (M160 1°serie) = SV CON PRESSOSTATO (M160 1°serie)

0101 = TRASDUTTORE + FLUSSIMETRO = TRASDUTTORE + FLUSSIMETRO

(M260, M160 2°serie)(M260, M160 2°serie)

0101 = SV CON TRASDUTTORE (M260, M160 2°serie) = SV CON TRASDUTTORE (M260, M160 2°serie)

0202 = TRASDUTTORE + FLUSSOSTATO (T160) = TRASDUTTORE + FLUSSOSTATO (T160)

0303 = PRESSOSTATO + FLUSSIMETRO = PRESSOSTATO + FLUSSIMETRO

P03P03 GESTIONE VELOCITA’ GESTIONE VELOCITA’ CIRCOLATORECIRCOLATORE

0000 = SEMPRE ALLA MASSIMA = SEMPRE ALLA MASSIMA

0101 = SEMPRE ALLA MINIMA = SEMPRE ALLA MINIMA

0202 = SELEZIONE AUTOMATICA = SELEZIONE AUTOMATICA

P04P04 GESTIONE ZONEGESTIONE ZONE 0000 = 1 ZONA (solo TA o solo remoto) = 1 ZONA (solo TA o solo remoto)0101 = TA + REMOTO e VALVOLA DI ZONA = TA + REMOTO e VALVOLA DI ZONA

(set temperatura + alta) (set temperatura + alta) (SOLO M260)(SOLO M260)

0202 = TA + REMOTO e VALVOLA DI ZONA = TA + REMOTO e VALVOLA DI ZONA

(set temperatura + bassa) (set temperatura + bassa) (SOLO M260)(SOLO M260)

03 03 = T160= T160

P05P05 TIPO GAS TIPO GAS 0000 : METANO : METANO

0505 : GPL : GPL

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI

Page 40: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLAYDISPLAY

REMOTOREMOTOFUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P06P06 NON UTILIZZATONON UTILIZZATO

P07P07 MASSIMA TEMPERATURA MASSIMA TEMPERATURA RISCALDAMENTO (°C)RISCALDAMENTO (°C)

45÷8545÷85 (DEFAULT 85°C)(DEFAULT 85°C)

P08P08 RIPRISTINO PARAMETRI RIPRISTINO PARAMETRI DI FABBRICADI FABBRICA

04 04 : : TUTTI I PARAMETRI RITORNANO AL TUTTI I PARAMETRI RITORNANO AL SETTAGGIO DI DEFAULT AD ECCEZIONE DI (Pr 01 SETTAGGIO DI DEFAULT AD ECCEZIONE DI (Pr 01 & Pr 05)& Pr 05)

3939 : : RESET DI TUTTI I PARAMETRI:RESET DI TUTTI I PARAMETRI:•Pr 05=00 => G20;Pr 05=00 => G20;•Pr 01=00 => Er 99 => NECESSARIO IMPOSTARE Pr 01=00 => Er 99 => NECESSARIO IMPOSTARE TIPO CALDAIATIPO CALDAIA

P09P09 INGRESSO MODALITA’ INGRESSO MODALITA’ SPAZZACAMINO PER SPAZZACAMINO PER TARATURA CALDAIATARATURA CALDAIA

0000 = FUNZIONE NON ATTIVA = FUNZIONE NON ATTIVA

0101 = MINIMO SANITRIO = MINIMO SANITRIO

0202 = MINIMO RISCALDAMENTO = MINIMO RISCALDAMENTO

0303 = MASSIMO RISCALDAMENTO = MASSIMO RISCALDAMENTO

0404 = MASSIMO SANITARIO = MASSIMO SANITARIO

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI

Page 41: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLAYDISPLAY

REMOTOREMOTOFUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P10P10 RITARDO RIACCENSIONE RITARDO RIACCENSIONE IN RISCALDAMENTOIN RISCALDAMENTO

00÷10000÷100 (0÷600 sec) (0÷600 sec) (DEFAULT 30 = 3 min)(DEFAULT 30 = 3 min)

P11P11 POST CIRCOLAZIONE IN POST CIRCOLAZIONE IN RISCALDAMENTORISCALDAMENTO

00÷10000÷100 (0÷600 sec) (0÷600 sec) (DEFAULT 10 = 1 min)(DEFAULT 10 = 1 min)

P12P12 POTENZA IN POTENZA IN RISCALDAMENTO %RISCALDAMENTO %

00 ÷10000 ÷100

00 00 == SOLO MINIMA POTENZASOLO MINIMA POTENZA

100 100 == NESSUNA RIDUZIONE (VEDI NESSUNA RIDUZIONE (VEDI DIAGRAMMA SU LIBRETTO CALDAIADIAGRAMMA SU LIBRETTO CALDAIA

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI

Page 42: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLAYDISPLAY

REMOTOREMOTOFUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P13P13 MODO POMPA MODO POMPA 0000 : ON SU RICHIESTA(DEFAULT) : ON SU RICHIESTA(DEFAULT)

0404 : SEMPRE IN FUNZIONE : SEMPRE IN FUNZIONE

P14P14 POTENZA DI POTENZA DI ACCENSIONEACCENSIONE

00÷10000÷100 (0÷100%) (0÷100%)

(DEFAULT: 50)(DEFAULT: 50)

P15P15 IMPOSTAZIONE VALORE K IMPOSTAZIONE VALORE K (SETTAGGIO SONDA (SETTAGGIO SONDA ESTERNA) ESTERNA)

00 00 = OFF (DEFAULT)= OFF (DEFAULT)

01 – 60 (Pr15=10=K1 Pr15=60=K601 – 60 (Pr15=10=K1 Pr15=60=K6

P16P16 POTENZA MINIMA POTENZA MINIMA RISCALD.RISCALD.

00÷10000÷100 (0÷100%) (0÷100%)

(DEFAULT: 00)(DEFAULT: 00)

P17**P17** SPEGNIMENTO IN SPEGNIMENTO IN SANITARIOSANITARIO

0000 = SET FISSO (65° C) (DEFAULT) = SET FISSO (65° C) (DEFAULT)

01 = SET POINT + 5°C01 = SET POINT + 5°C

02 = SET POINT + 3°C 02 = SET POINT + 3°C

P18P18 ABILITAZIONE NTC SU ABILITAZIONE NTC SU RITORNO RITORNO RISCALDAMENTORISCALDAMENTO

0000 : : NON PRESENTENON PRESENTE

01 : PRESENTE01 : PRESENTE

** NB: Se la scheda viene settata per bollitore con sonda ntc allora P17 determina la frequenza di attivazione della funzione antilegionella

P17 = 01 ANTILEGIONELLA OGNI 2 GGP17 = 01 ANTILEGIONELLA OGNI 2 GG

P17= 02 ANTILEGIONELLA OGNI 3 GGP17= 02 ANTILEGIONELLA OGNI 3 GG

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI

Page 43: Service RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO COMANDO

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLAYDISPLAY

REMOTOREMOTOFUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P24P24 DUTY CICLEDUTY CICLE 0 ÷ 30 0 ÷ 30 (DEFAULT 0)(DEFAULT 0)

0 0 = VALVOLA DI ZONA SEMPRE APERTA CON = VALVOLA DI ZONA SEMPRE APERTA CON RICHIESTA RICHIESTA

1 ÷ 30 1 ÷ 30 MINUTI DEL CICOLO DI MINUTI DEL CICOLO DI APERTURA/CHIUSURA DELLA VALVOLA DI APERTURA/CHIUSURA DELLA VALVOLA DI ZONAZONA

P27P27 TEMPERATURA MINIMA TEMPERATURA MINIMA RISCALDAMENTORISCALDAMENTO

25÷4525÷45 (DEFAULT 25°) (DEFAULT 25°)

P28P28 SCADENZA SCADENZA MANUTENZIONEMANUTENZIONE

00 ÷ 48 00 ÷ 48 (DEFAULT 12 MESI)(DEFAULT 12 MESI)

P29P29 NTC INGRESSO NTC INGRESSO SANITARIOSANITARIO

0000 = NON PRESENTE = NON PRESENTE

0101 = PRESENTE = PRESENTE

0404 = CENTRALINA SOLARE COLLEGATA = CENTRALINA SOLARE COLLEGATA

P30P30 PRESSIONE IMPIANTO PRESSIONE IMPIANTO RISCALDAMENTO RISCALDAMENTO CORRETTA CORRETTA

1010 (sotto 1,0 bar si accende l’icona di (sotto 1,0 bar si accende l’icona di richiesta carico) (richiesta carico) (SOLO M260)SOLO M260)

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI