DRÄGER EVITA INFINITY® V50002 |

Hospitals around the world are under increased financial pressure. Competitionfor patients is increasing and clinics are often required to benchmark qualityand outcome.

Under pressure

Need for standardizationInconsistent user interfaces, operating concepts,nomenclature and accessories for differentmodalities is a reality in many hospitals. There’s noeasy way to share and download information. Thismeans increased training and a higher risk ofsignificant medical error.

Data overloadMedical personnel have to analyze and interpret aconstant stream of raw data from various sources.Long working hours and the fast pace of ICUenvironments can compromise clinical decision-making.

Inner-hospital transport Transporting a ventilated patient can be risky; one isoften forced to compromise between performanceand portability when changing between a bedsideand a transport ventilator. In addition, setting updedicated transport equipment can be timeconsuming.

The solution to these and other problems can onlycome from an increase in efficiency. Technology canhelp you streamline workflow, access and interpretdata, automate processes and much more. Dräger has been making technology for life for overa century, and we firmly believe that an essentialelement of any successful health care strategy lies inchoosing the right technology to accomplish yourgoals.

Many hospitals share a number of challenges whichcan have a negative effect on workflow efficiencyand, ultimately, the quality of care.

COMMON HOSPITAL CHALLENGES

Challenging workplace ergonomicsDevice placement issues, cable clutter, limitedpatient access and unintuitive user interfaces; it’s anenvironment that can divert your attention away fromyour primary concern – the patient.

Limited flexibilityCompatibility of components and interfaces isseverely limited. There are just too many proprietarysolutions. In addition, equipment is often notdesigned to adapt to changing needs.

MT-1811-200

8

MT-1816-200

8

DRÄGER EVITA INFINITY® V500 | 03

More than just advanced respiratory therapy, thesynergy provided by the Infinity® Acute CareSystem™ can help you meet the challenges oftoday's health care environment:

Equipped with features that go beyond standard ventilation - the V500 is ahighly advanced ventilator for use in modern, acute care respiratory support.

The Dräger Evita Infinity® V500, a component of the Infinity® Acute Care System™

SMART

– use technology to turn data into information

MOBILE

– make technology available wherever you need it

SCALABLE

– expand the system to suit your needs

STANDARDIZED

– connect components quickly and easily

INTEGRATED

– combine several useful functions in a single device

MT-60

73-200

8

22

8.2

4.65.82

13

266

7993167/69118

07:27

ED

Thesolution

DRÄGER EVITA INFINITY® V50004 |

SmartCare®/PS is the automatic, knowledge-basedweaning system. The new version of SmartCare®/PSlets you configure weaning parameters for enhancedflexibility and control:– SmartCare®/PS has been shown to reduce

weaning times by up to 40% and ventilation timesby up to 33%1). This can help improve outcomeand reduce risks while simultaneously loweringcosts.

The Smart Pulmonary View performs real-timevisualization of pulmonary function data. By turningdata into useful visual information, the SmartPulmonary View helps reduce the cognitiveworkload of ICU staff.– Visual representation of data in real time – Intuitive anatomical analogy– Reduction of cognitive load

Infinity® ID accessories were developed to simplifyhandling and optimize workflow:– Mismatch control detects false connections of

the circuit to the ports and triggers an alarm,virtually eliminating the possibility of mismatchedbreathing circuits.

– Configuration control detects the connectedbreathing circuit type and adjusts device settingsaccordingly.

– Exchange control reminds personnel ofpreselected replacement intervals for breathingcircuits, disposable expiration valve and watertrap.

– Transfer of ventilation settings copies ventilationsettings just by connecting the circuit to anotherV500.

Incorporating automated weaning, visualization of pulmonary functions and RFID-based technology – the V500 is a smart choice.

Smart

1) F. Lellouche et al.; Am J respir Care Med Vol 174, pp 894-900, 2006. Results are based on a European Multicenter Randomized Trial with 144

patients demonstrating improved respiratory condition, with stable hemodynamic and neurologic status, and no ARDS prior to initiating weaning

MT-08

23-200

8

MT-08

19-200

8

ICU venti The advanced integrated

DRÄGER EVITA INFINITY® V50005 |

The mobile power supply PS500 greatly expandsyour transport range:– This compact yet powerful battery pack will give

you at least 100 minutes of independent power.

The GS500 mobile air supply provides air whereverneeded:– The GS500 is an electrically driven, turbine

powered air supply unit that can keep youindependent of a compressed air sourceindefinitely.

The Transport Supply Unit TSU lets you transportoxygen cylinders easily:– The optional TSU can be quickly attached to the

V500 transport trolley for ergonomic handling oflarge cylinders.

High level ventilation therapy during transport – that’s mobility with the V500.

Mobile

The V500 is equipped with standardized interfacesfor optional hardware components or softwareupgrades.– The device-set-up can be adjusted to changing

patient needs over the course of treatment. – For the treatment of all patient ranges, the V500

provides optional neonatal ventilation capabilities.– Additional Infinity® Acute Care System™

components linked to the system will revealpotential synergies departmental or crossdepartmental level.

Uncompromising scalability now and in the future - the V500 is a safeinvestment.

Scalable

MT-08

21-200

8

MT-08

18-200

8

lation system

| 06DRÄGER EVITA INFINITY® V500

With its configuration export function, you can easilycopy user interface, therapy and alarm configurationsto a standard USB storage device.– V500s can be easily standardized with the

configuration of your choice within minutes.– This same function also allows a quick export of

screen dumps and data, such as logbooks andtrends, further supporting information exchangeand documentation.

– A common medical cockpit supports cross-departmental standardization with alignednomenclature. And the user-friendly operatingconcept helps to reduce training efforts andmakes the V500 easy to learn and to operate.

– Workplace integration: V500 can be mounted to a38mm pole or on vertical front rails.

– Power and air integration: Secure independencefrom air and power supplies with the GS500 andPS500.

– Service integration: The Infinity® Service programensures that your V500 can always be updatedwith the latest software and helps to maximizedevice uptime.

Setting your individual standard –quick and easy configuration withthe V500.

Standardized

An integral system component with exciting standalone features – the V500.

Integrated

MT-08

24-200

8

MT-08

20-200

8

Invasive ventilationAside from a complete range of standard invasiveventilation patterns, the V500 incorporates advancedinvasive ventilation features not found in any otherventilator.

SmartCare®/PS– The automated, knowledge based weaning

system, now complete with configurable weaningprotocol parameters for added flexibility.

Variable PS– Subtle, random variations in inspiratory pressure

have been shown to have a positive effect onpulmonary function.2) This “noisy” PS ventilationmimics the natural variation of biological systems.

APRV AutoRelease– Dräger’s APRV AutoRelease automatically

optimizes Tlow to terminate expiration at anadjustable percentage of peak expiratory flow,keeping end-expiratory lung volume and CO2

removal optimally balanced, even in the face ofchanging respiratory mechanics and expiratoryflow patterns.

Full-featured, non-invasive ventilation.– With its automatic, dynamic compensation

features, the V500 successfully manages one of the most common issues in NIV: leaks. In order to rapidly restore optimal synchrony, the V500 recognizes and compensates for leaksquickly by adjusting both inspiratory trigger andtermination points.

The Dräger Infinity® V500 gives youworld-class ventilation designed forpatients of all ages and acuity levels.

DRÄGER EVITA INFINITY® V500 | 07

MT-60

73-200

8

Invasive and non-invasive

ventilation

2) Abreu MG; Noisy pressure support ventilation: A pilot study on a new assisted ventilation mode in experimental lung injury;

Crit Care Med 2008 Vol. 36, No. 3

90 66 35

0 | 09

.10-3 | Marketing Com

munications | LSL | LE

| Prin

ted in G

ermany | Chlorine-free –

environm

entally com

patible

| Sub

ject to

mod

ifications

| © 2010 Dräge

rwerk AG & C

o. KGaA

Manufacturer:Dräger Medical GmbH23542 Lübeck, GermanyThe quality management system atDräger Medical GmbH is certifiedaccording to ISO 13485, ISO 9001and Annex II.3 of Directive93/42/EEC (Medical devices).

HEADQUARTERSDrägerwerk AG & Co. KGaAMoislinger Allee 53–5523558 Lübeck, Germany

www.draeger.com

REGION EUROPE CENTRAL AND EUROPE NORTHDräger Medical GmbH Moislinger Allee 53–5523558 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 [email protected]

REGION EUROPE SOUTHDräger Médical S.A.S. Parc de Haute Technologie d’Antony 225, rue Georges Besse92182 Antony Cedex, FranceTel +33 1 46 11 56 00Fax +33 1 40 96 97 [email protected]

REGION MIDDLE EAST, AFRICA, CENTRAL AND SOUTH AMERICADräger Medical GmbHBranch Office DubaiDubai Healthcare CityP.O. Box 505108Dubai, United Arab EmiratesTel + 971 436 24 762Fax + 971 436 24 [email protected]

REGION ASIA / PACIFICDraeger Medical South East Asia Pte Ltd25 International Business Park#04-27/29 German CentreSingapore 609916, SingaporeTel +65 6572 4388Fax +65 6572 4399 [email protected]

REGION NORTH AMERICADraeger Medical, Inc.3135 Quarry Road Telford, PA 18969-1042, USATel +1 215 721 5400Toll-free +1 800 437 2437Fax +1 215 723 [email protected]