seven catalog
DESCRIPTION
Seven CatalogTRANSCRIPT
®
M A K E I T S I M P L E
A self-tapping internal hex. by
P.15
P.16-17
P.18-19
P.20-21
P.22
P.23
P.24-25
P.14
P.13
P.12
P.11
P.10
P.9
P.8
P.6-7
P.4-5
MIS Warranty:
MIS exercises great care and effort in maintaining a superior quality of products. All MIS' products are guaranteed to be clear from defects in material and workmanship. However, should a customer find fault with any MIS product while using it according to the instructions, the defective product will be replaced.
Warning: MIS' products should be used by licensed dentists only.
Introduction
Advantages
Implant range Narrow Platform
Ø3.30mm Implants
Implant range Standard Platform
Ø3.75mm Implants
Ø4.20mm Implants
Implant range Wide Platform
Ø5mm Implants
Ø6mm Implants
Drilling Procedures
Surgical Kit
Success
Delivery keys
Insertion Options.
Packaging
Table of contents.
4.
© MIS Corporation. All rights reserved.
Always dedicated to the development of innovative
products and technologies, MIS' scientists and engineers
conduct continuous laboratory and field studies in
collaboration with prestigious universities and dental
research institutes. SEVEN is the innovative result of an
extensive research and development process, offering a
unique combination of surgical and restorative benefits.
4.
6.
Advantages.
Screw type implant standard platform Ø 4.20mm.
Internal hex.MIS SEVEN implants feature an internal hex. connection, assuring proper implant abutment seating, anti-rotational engagement, resistance to lateral forces, excellent esthetic results and more.
Micro ringsMicro rings on the implant’s neck improve BIC (Bone To Implant Contact) at the crestal zone.
Dual threadA dual thread design increases BIC (Bone to Implant Contact), reinforcing osseointegration for long lasting clinical success. The overall insertion rate of SEVEN is 2.4mm per revolution.
Conical shapeConical, root-shaped geometry and a unique thread design ensure superior primary stability offering the ultimate choice for a wide range of clinical cases and loading protocols.
SurfaceThe surface roughness and micro-morphology is a result of sand blasting and acid etching. MIS' established surface technology has provided millions of patients and clinicians with excellent osseointegration results and long lasting clinical success.
Domed apexThe dome shaped apex prevents over-insertion for safer implant placement procedures.
Three spiral channelsThree spiral channels at the apical end of the implant support its self tapping properties. The channels also collect and amass bone chips in the course of insertion, supporting efficient osseointegration and long-term stability.
13mm 16mm11.50mm8mm6mm 10mm
Ø3.30mm
MF7-10330
MF7-11330
MF7-13330
MF7-16330
®
Type
8.
Ø3.30mm
MF7-10330
MF7-11330
MF7-13330
MF7-16330
MT-SRA10
MT-HLI10
MT-HSI10
MT-SHA10
MT-NRH20
MC1-00330
2/3/4mm
Ø 4mm
MH-N2330MH-N3330MH-N4330
Narrow PlatformScrew type implants range
Length
Surgical tools
Square connection to ratchet adapter
Long insertion tool, int. hex. connection
Short insertion tool, int. hex. connection
Hand wrench square connection
Hex. ratchet long adapter for int. hex. connection, NP
Available for heights: 2,3,4mm
Implant cover screws and healing caps
NARROW
.Catalog No Dimensions
Ø 2.40
Ø 3.30
2.10
Ø 2.20
Ø 3.20
L
Ø3.30mm
®
MF7-10330
MF7-11330
MF7-13330
MF7-16330 Ø3.30mm
Ø3.30mm
Ø3.30mm
Ø3.30mm
The drilling sequence is demonstrated by a 13mm implant.
Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.
Do not use the final drill for bone type 3&4
Narrow Platform
Titanium Alloy Ti 6Al 4V ELISand Blasted and Acid-Etched
Final DrillEach implant is supplied with a single use final drill corresponding to its diameter and length, allowing a short and safe drilling procedure.
DimensionsCatalog No.
1200-1500
Ø2.40 Ø3.30Ø1.90
900-1200
15-25
Ø2.20 Ø3.20
200-400
Ø2.40
Ø3.30mm Implant Procedure
Drilling Speed (RPM)
Diameter
For bonetype 1&2
Final drill
length 10mm
length 11.50mm
length 16mm
length 13mm
NARROW
13mm 16mm11.50mm8mm6mm 10mm
Ø 3.75mm
MF7-08375
MF7-10375
MF7-11375
MF7-13375
MF7-16375
Ø 4.20mm
MF7-06420
MF7-08420
MF7-10420
MF7-11420
MF7-13420
MF7-16420
Type
®
10.
Ø 3.75mm
MF7-08375
MF7-10375
MF7-11375
MF7-13375
MF7-16375
Ø 4.20mm
MF7-06420
MF7-08420
MF7-10420
MF7-11420
MF7-13420
MF7-16420
MT-SRA10
MT-SHA10
MT-HLI10
MT-HSI10
MC1-00375
MH-53375MH-54375MH-55375MH-56375
MH-03375MH-04375MH-05375MH-06375
3/4/5/6mm
Ø 4mm
3/4/5/6mm
Ø 5.5mm
Available for heights: 3,4,5,6mm
Implant cover screws and healing caps
Standard PlatformScrew type implants range
Length
Surgical tools
Square connectionto ratchet adapter
Hand wrenchsquare connection
Long insertion tool, int.hex. Connection
Short insertion tool, int.hex. Connection
STANDARD
.Catalog No Dimensions
Ø 3.10
Ø 3.75
2.45
Ø 2.80
Ø 3.60
L
Ø3.75mm
®
MF7-10375
MF7-11375
MF7-13375
MF7-16375
1200-1500
900-1200
Ø1.90 Ø2.80 Ø3.75Ø2.40 Ø2.40
500-700 15-25
Ø2.8 Ø3.60
Ø3.75
200-400
200-500
Ø2.80
Ø3.75mm
(MT-GDN33)
Ø3.75mm
Ø3.75mm
Ø3.75mm
Ø3.75mm
Ø3.75mm
Ø3.75Ø3.75
(MT-GDN33)(MT-GDN33)
MF7-08375
The drilling sequence is demonstrated by a 13mm implant.
Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.
Do not use the final drill for bone type 3&4
Implant Procedure
Drilling Speed (RPM)
Diameter
Catalog No. Dimensions
Titanium Alloy Ti 6Al 4V ELISand Blasted and Acid-Etched
Final DrillEach implant is supplied with a single use final drill corresponding to its diameter and length, allowing a short and safe drilling procedure.
Standard Platform
For bonetype 3&4
Countersink For bonetype 1&2
Final drill
length 8mm
length 10mm
length 11.50mm
length 16mm
length 13mm
OR
STANDARD
Ø3.30
Ø4.10
Ø 3.70
Ø 3.75
2.45
0.4mm
Ø 4.20
L
Ø4.20mm
®
MF7-06420
MF7-08420
MF7-10420
MF7-11420
MF7-13420
MF7-16420
Ø5mm
MF7-06500
MF7-08500
MF7-10500
MF7-11500
MF7-13500
MF7-16500
Ø6mm
MF7-06600
MF7-08600
MF7-10600
MF7-11600
MF7-13600
12.
1200-1500
900-1200
Ø2.40 Ø2.80Ø1.90 Ø2.40
500-700
Ø3.20 Ø3.20
400-700
Ø3.30Ø4.10
Ø3.30Ø4.20
200-400
200-500
Ø4.20
15-25
Ø4.20mm
Ø4.20mm
Ø4.20mm
Ø4.20mm
Ø4.20mm
Ø4.20mm
Ø4.20mm
Ø4.20Ø4.20
15-2515-25
The drilling sequence is demonstrated by a 13mm implant.
Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.
Do not use the final drill for bone type 3&4
Final DrillEach implant is supplied with a single use final drill corresponding to its diameter and length, allowing a short and safe drilling procedure.
Implant Procedure
Drilling Speed (RPM)
Diameter
Titanium Alloy Ti 6Al 4V ELISand Blasted and Acid-Etched
Standard PlatformCatalog No.
For bonetype 1&2
Final drillCountersink(MT-GDN33)
For bone type 3&4
length 6mm
length 8mm
length 10mm
length 11.50mm
length 13mm
length 16mm
Dimensions
OR
STANDARD
13mm 16mm11.50mm8mm6mm 10mm
®
Ø5mm
MF7-06500
MF7-08500
MF7-10500
MF7-11500
MF7-13500
MF7-16500
Ø6mm
MF7-06600
MF7-08600
MF7-10600
MF7-11600
MF7-13600
MH-W3500MH-W4500MH-W5500
3/4/5mm
Ø 5mm
MH-W3630MH-W4630MH-W5630
MT-SRA10
MT-SHA10
MT-HLI10
MT-HSI10
MC1-00470
3/4/5mm
Ø 6.5mm
Available for heights: 3,4,5mm
Implant cover screws and healing caps
Square connectionto ratchet adapter
Hand wrenchsquare connection
Long insertion tool, int.hex. Connection
Short insertion tool, int.hex. Connection
Surgical tools
Wide PlatformScrew type implants range
Length
TypeTitanium Alloy Ti 6Al 4V ELISand Blasted and Acid-Etched
WIDE
Ø 4.50
Ø 4.50
0.4mm
Ø 4.10
Ø 4.90
2.45
Ø 5
L
Ø5mm
®
MF7-06500
MF7-08500
MF7-10500
MF7-11500
MF7-13500
MF7-16500
14.
Ø4.10 Ø 4.90
Ø5
200-400
200-500
Ø5
15-25
Ø4
400-600
1200-1500
900-1200
Ø2.40 Ø2.80 Ø3.20Ø2.40Ø1.90
500-700
400-700
Ø5mm
Ø4
Ø5mm
Ø5mm
Ø5mm
Ø5mm
Ø5mm
Ø5mm
The drilling sequence is demonstrated by a 13mm implant.
Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.
Do not use the final drill for bone type 3&4
Drilling Speed (RPM)
Diameter
Implant Procedure
Final DrillEach implant is supplied with a single use final drill corresponding to its diameter and length, allowing a short and safe drilling procedure.
Titanium Alloy Ti 6Al 4V ELISand Blasted and Acid-Etched
Wide PlatformCatalog No. Dimensions
length 6mm
length 8mm
length 10mm
length 11.50mm
length 13mm
length 16mm
For bonetype 3&4
For bonetype 1&2
Final drill CountersinkMT-GDN50
OR
WIDE
Ø 5.10
Ø 4.50
Ø 5.50
Ø 6
0.4mm
Ø 5.90
2.45
L
Ø6mm
®
MF7-06600
MF7-08600
MF7-10600
MF7-11600
MF7-13600
Ø5.10 Ø 5.90
Ø6
200-400
200-500
Ø6
15-25
Ø4
400-600
300-500
300-500
1200-1500
900-1200
Ø2.40 Ø2.80 Ø3.20Ø2.40Ø1.90
500-700
400-700
Ø6mm
Ø4.50 Ø5 Ø5
Ø6mm
Ø6mm
Ø6mm
Ø6mm
Ø6mm
Ø5Ø5
Final DrillEach implant is supplied with a single use final drill corresponding to its diameter and length, allowing a short and safe drilling procedure.
Titanium Alloy Ti 6Al 4V ELISand Blasted and Acid-Etched
Drilling Speed (RPM)
Diameter
Implant Procedure
Wide PlatformCatalog No. Dimensions
length 6mm
length 8mm
length 10mm
length 11.50mm
length 13mm
For bonetype 1&2
Final drill
For bonetype 3&4
CountersinkMT-GDN50
OR
WIDE
BO
DY T
RY
IN Ø
5
SPADE MARKING DRILL Ø1.90 SPADE MARKING DRILL Ø
1.90
S
PAD
E M
ARKI
NG
DR
ILL
Ø1.9
0
PILOT DRILL Ø2.40 PILOT DRILL Ø2.40
P
ILO
T D
RIL
L Ø
2.40
BODY TRY IN Ø2.40 BODY TRY IN Ø2.40
BO
DY T
RY
IN Ø
2.40
FINAL DRILL
TWIST DRILL Ø
2.80
T
WIS
T D
RIL
L Ø
2.80
FINAL D
RILL
IMPLANT
BODY TRY IN Ø2.80
T
WIS
T D
RIL
L Ø
3.20
COUNTERSINK
FINAL D
RILL
T
WIS
T D
RIL
L Ø
4
TWIS
T D
RIL
L Ø
4.50
TWIS
T D
RIL
L Ø
5
COUNTERSINK
FINAL DRILL
SPADE MARKING DRILL Ø1.90
SPADE M
ARKING D
RILL
Ø1.9
0
PILOT DRILL Ø2.40
PILOT D
RILL Ø
2.40
BODY TRY IN Ø2.40
B
ODY
TRY
IN Ø
2.40
TWIST DRILL Ø2.80
TWIST D
RILL Ø
2.80
TWIST DRILL Ø3.20
T
WIST D
RILL Ø
3.20
TWIST DRILL Ø4
BODY TRY
IN Ø
3.20
BODY TRY IN Ø4 COUNTERSINK
FI
NAL
DR
ILL
COUNTERSINK
FINAL DRILL
Ø3.30
Ø3.75
Ø4.20
Ø5
Ø6
16.
Implant
DrillingProcedures.
BO
DY T
RY
IN Ø
5
SPADE MARKING DRILL Ø1.90 SPADE MARKING DRILL Ø
1.90
S
PAD
E M
ARKI
NG
DR
ILL
Ø1.9
0
PILOT DRILL Ø2.40 PILOT DRILL Ø2.40
P
ILO
T D
RIL
L Ø
2.40
BODY TRY IN Ø2.40 BODY TRY IN Ø2.40
BO
DY T
RY
IN Ø
2.40
FINAL DRILL
TWIST DRILL Ø
2.80
T
WIS
T D
RIL
L Ø
2.80
FINAL D
RILL
IMPLANT
BODY TRY IN Ø2.80
T
WIS
T D
RIL
L Ø
3.20
COUNTERSINK
FINAL D
RILL
T
WIS
T D
RIL
L Ø
4
TWIS
T D
RIL
L Ø
4.50
TWIS
T D
RIL
L Ø
5
COUNTERSINK
FINAL DRILL
SPADE MARKING DRILL Ø1.90
SPADE M
ARKING D
RILL
Ø1.9
0
PILOT DRILL Ø2.40
PILOT D
RILL Ø
2.40
BODY TRY IN Ø2.40
B
ODY
TRY
IN Ø
2.40
TWIST DRILL Ø2.80
TWIST D
RILL Ø
2.80
TWIST DRILL Ø3.20
T
WIST D
RILL Ø
3.20
TWIST DRILL Ø4
BODY TRY
IN Ø
3.20
BODY TRY IN Ø4 COUNTERSINK
FI
NAL
DR
ILL
COUNTERSINK
FINAL DRILL
Ø5Ø4.50Ø4 Ø5Ø4Ø3.20Ø3.20Ø2.80Ø2.80Ø2.40Ø2.40
Spade / marking drill Ø1.90mm
Pilot drill Ø2.40mm
Body try in Ø2.40mm
Twist drill Ø2.80mm
Twist drill Ø3.20mm
Twist drill Ø4mm
Twist drill Ø4.50mm
Body try in Ø5mm
Countersink
Body try in Ø2.80mm
Body try in Ø3.20mm
Body try in Ø4mm
Twist drill Ø5mm
Final drill
STANDARD
NARROW
WIDE
MT-TDT28MT-BTT24 MT-BTT28 MT-RI030
MT-TDN19
MT-PP240
MT-P2416
MT-P2413
MT-NRH20
18.
MT-SMD10
MT-P2408
MT-P2406
MT-P2410
MT-P2411
With external irrigation drills
Advanced Surgical Instrument Kit.
MK-EI48
MT-BTT32 MT-BTT40 MT-BTT45
MT-GDN33
MT-GDN50
MT-SM005
MT-DE001
MT-SHA10
MT-LM005
MT-SRA10
MT-TDT32 MT-TDN40 MT-TDT45
MT-TDN50
MT-HMR10
MT-HSI10
MT-HLI10
MT-TDN50MT-TDN50MT-TDN50MT-TDN50
MT-BTT50
MT-DI001
20.
Micro Structure - Surface Morphology
The surface roughness and microgeometry is achieved by blasting particles and acid-etching. As a result, a larger surface area increases bone-to-implant contact, for long lasting osseointegration.The micro mechanical fixation increases implant stability.
Success.
SEVEN implants' high success rate is guaranteed by a combination of advanced geometric design and a cutting-edge surface technology.
20
15
10
5
0
Microgram
Implant
Jerusalem, Israel, IADRAugust 03, 2004
Hebrew University
Adsorption of Serum Protein to Modified Titanium SurfacesM.N. Sela, L.Badihi, G.Rosen, D.Kohavi and D. Steinberg
The use of Titanium (Ti) implants is a novel clinical procedure in dentistry. The adsorption of biological molecules to the implant’s surface triggers a sequence of events that may determine the outcome of this procedure. Clinical data suggests that modified Ti surfaces play an important role in the success or failure of the implant. Objective: the purpose of this study was to investigate the interaction between Ti implants with different surface properties and serum proteins, in order to find the optimal implant surfaces which may improve the Osseointegration process and implant intake.
Materials & Methods: Six mm in diameter Ti disks with two types of surface modifications were compared: Machined and Sandblast plus Acid-Etched. The disks were coated with mixtures of Human Serum Albumin conjugated with fluorescein (HAS-FITC).
Following incubation, the coat was removed from the disks by SDS. A Confocal Scanning Laser Microscope was used to visualize and measure the HAS-FITC coat and the degree of protein removal from the Ti surfaces.
Results: The Confocal Microscope images revealed a significantly higher amount of HAS-FITC coat on the rough disks, as compared with the machined disks. Furthermore, under similar experimental conditions, less HAS-FITC could be removed from the rough disks than from the machined disks.
Conclusions: Absorption of albumin to the rough treated Ti surface is both qualitatively and quantitatively far more intense, as compared with the machined surfaces. Further studies of the chemical and physical characterization of the modified Ti surfaces are underway. Moreover, additional serum proteins, as well as oral microorganisms, are being examined for their interactions with the modified Ti surfaces.
Albumin
IGG
Fibronectin
Fibrinogen
Machine
Machine
MIS Surface
20.22.
MT-HLI10
MT-SRA10
MT-SHA10 MT-HSI10
Han
d w
renc
h sq
uare
con
nect
ion
Squ
are
conn
ectio
n to
rat
chet
ada
pter
Long
inse
rtio
n to
ol, i
nt. h
ex. C
onne
ctio
n
Sho
rt in
sert
ion
tool
, int
. hex
. Con
nect
ion
Available within MIS' advanced surgical kit, the SEVEN key system is designed to facilitate quick and reliable implants procedures.
The new keys are suitable for use with SEVEN NARROW connectors.
Delivery keys.
20.
1.
2.
3.
13
22
The unique "3 in One" key system minimizes the number of tools, and maximizes flexibility.
Insertion Options.
The improved insertion tool allows the delivery of a cover screw or a healing cap onto the implant after its insertion.
Please note: In order to assure their efficient operation, keys should be fully inserted into the implants. A complete insertion of the key optimizes the transfer of force during implant placement and enables simple.release of the key from the hex. whenever necessary
Please note: Key will not hold implant unless it is complety forced into the hex.
Insertion tool in hand key adapter
Insertion tool for motor
Insertion tool in ratchet adapter
24.
Each SEVEN implant comes with a large range of sterilized components for any clinical scenario.
Following the “Make It Simple” philosophy, MIS is proud to be the first to include a sterile single use final drill with every SEVEN implant, to ensure safe and precise surgical procedure.
Package Content.
Cov
er S
crew
Fina
l Dril
l
Insi
de T
ube
Out
side
Tub
e
Impl
ant
Advantages.
Easy pull tab
Implant identification
The easily identified pull tab facilitates quick and easy opening during surgery.
A sticker on top of the box, specifies implant's diameter, length and platform size.
Implant diameter & platform indicationThe outer tube is color-coded, indicating the implant's platform. The numeric indication specifies implant's diameter and length.
Prosthetic platform indicationProsthetic components are marked by specific colors, representing their platforms.
A double packing system ensures sterilization and safety. Packages are designed for ease of use during surgery and for use with surgical gloves.
Packaging.
® All rights reserved. No part of this publication may be reproduced, transcribed, stored in an electronic retrieval system, translated into any language or computer language, or be transmitted in any form whatsoever, without the prior written consent of the publisher.
Authorized European Representative:MIS Germany, Paulinenstraße 12a, 32427 Minden, GERMANY
ISO 9001:2000ISO 13485:20030483
© MIS Corporation. All Rights Reserved.
MIS Implants Technologies Ltdwww.mis-implants.com
MC
-UN
O08 R
ev.1M
C-U
NO
08 Rev.1
© MIS Corporation. All rights reserved.
MIS’ Quality System complies with
international quality standards: ISO
13485:2003 - Quality Management System
for Medical Devices, ISO 9001: 2008 - Quality
Management System and CE Directive for
Medical Devices 93/42/EEC. MIS’ products
are cleared for marketing in the USA and
CE approved.
MC
-SE
VE
N R
ev.11
MIS Implants Technologies Ltd.www.mis-implants.com
®