shaft-vibration · pdf file · 2017-06-24emerson’s dual-channel...

14
Specifications Sheet May 2015 CSI 3110 www.emersonprocess.com/csi Shaft-Vibration Monitor Emerson’s Dual-Channel Shaft-Vibration Monitor is designed for small and low channel applications such as small steam, gas, and hydro turbines, and such as compressors, pumps, and fans to measure relative shaft vibration signals. Measurement settings, alarms, and provided outputs are field configurable via software. Measurement Performance Sensor Input Type Eddy- Current Sensors Measurement Range: Sensor PR6422 0 to 250 µm Sensor PR6423 0 to 500 µm Sensor PR6424 0 to 1000 µm Sensor PR6425 0 to 1000 µm Frequency Range: High-Pass Filter 1 / 5 / 10 Hz Low-Pass Filter 50 to 1500 Hz Connection Type: Internal Converter “LEMO” socket External Converter “Harting” socket Environmental Shock Limit 20 g pk Temperature Range -20 to 65°C (-4 to149°F) Sealing IP65 Agency Ratings CE Mechanical Case Material / Weight Aluminum, stainless / ~ 1300 g (45.8 oz.) Mounting Wall mount Electrical Supply Voltage Nominal +24 VDC Permissible Voltage Range +18 to +31.2 VDC Power Consumption max. 6 W Buffered Out: Connection BNC and/or Pins (Cage Terminal) (2x) Voltage Range 2.0 to 10.0 VDC Accuracy ± 2.5% Shown here is one product option. Other options have slightly different sockets and wiring.

Upload: phamanh

Post on 08-Mar-2018

220 views

Category:

Documents


1 download

TRANSCRIPT

Specifications Sheet May 2015 CSI 3110

www.emersonprocess.com/csi

Shaft-Vibration MonitorEmerson’s Dual-Channel Shaft-Vibration Monitor is designed for small and low channel applications such as small steam, gas, and hydro turbines, and such as compressors, pumps, and fans to measure relative shaft vibration signals. Measurement settings, alarms, and provided outputs are field configurable via software.

Measurement Performance

Sensor Input Type Eddy- Current Sensors

Measurement Range: Sensor PR6422 0 to 250 µm

Sensor PR6423 0 to 500 µm

Sensor PR6424 0 to 1000 µm

Sensor PR6425 0 to 1000 µm

Frequency Range: High-Pass Filter 1 / 5 / 10 Hz

Low-Pass Filter 50 to 1500 Hz

Connection Type: Internal Converter “LEMO” socket

External Converter “Harting” socket

Environmental

Shock Limit 20 g pk

Temperature Range -20 to 65°C (-4 to149°F)

Sealing IP65

Agency Ratings CE

Mechanical

Case Material / Weight Aluminum, stainless / ~1300 g (45.8 oz.)

Mounting Wall mount

Electrical

Supply Voltage Nominal +24 VDC

Permissible Voltage Range +18 to +31.2 VDC

Power Consumption max. 6 W

Buffered Out: Connection BNC and/or Pins (Cage Terminal)

(2x) Voltage Range 2.0 to 10.0 VDC

Accuracy ± 2.5%

Shown here is one product option. Other options have slightly different sockets and wiring.

Specifications Sheet May 2015 CSI 3110

2

Current Out: Current Range 0/4 to 20 mA (20 to 4/0 mA)

(2x) Galvanically separated

Open circuit and short-circuit proof

Maximum Burden 500 Ohm

Relay Out: Voltage UMAX: 48 VDC

(5x make contact) Current IMAX: 1 A

Contact Rating PMAX: 50 W

Ordering Information

Part Number Description

A3110/022-000 CSI 3110 Shaft-Vibration Monitor Eddy-Current Converters: INTERNAL

A3110/022-020 CSI 3110 Shaft-Vibration Monitor Eddy-Current Converters: EXTERNAL (to be ordered separately)

Dimensions

A 3110/022-000

Specifications Sheet May 2015 CSI 3110

www.emersonprocess.com/csi

Emerson Process ManagementReliability Solutions835 Innovation DriveKnoxville, TN 37932 USAT 1(865) 675-2400

©2015, Emerson Process Management. All rights reserved.

The Emerson logo is a trademark and service mark of Emerson Electric Co. Machinery Health is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners.

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.

A3110 /022-020

Specifications Sheet May 2015 CSI 3120

www.emersonprocess.com/csi

Bearing-Vibration MonitorEmerson’s Dual-Channel Bearing-Vibration Monitor is designed for small and low channel applications such as small steam, gas, and hydro turbines, and such as compressors, pumps, and fans to measure absolute bearing vibration signals. Measurement settings, alarms, and provided outputs are field configurable via software.

Measurement Performance

Sensor Input Type Seismic Sensors of Type PR9268

Measurement Range Freely selectable by means of configuration software according to the measuring range of the applied sensors

Frequency Range: High-Pass Filter 5 / 10 / 15 Hz

Low-Pass Filter 50 to 1500 Hz

Connection Type “Harting” socket

Environmental

Shock Limit 20 g pk

Temperature Range -20 to 65°C (-4 to149°F)

Sealing IP65

Agency Ratings CE

Mechanical

Case Material / Weight Aluminum, stainless / ~1300 g (45.8 oz.)

Mounting Wall mount

Electrical

Supply Voltage Nominal +24 VDC

Permissible Voltage Range +18 to +31.2 VDC

Power Consumption max. 6 W

Buffered Out: Connection Available at Pins (Cage Terminal)

(2x) Voltage Range ±5.0 VDC

Accuracy ± 2.5%

Current Out: Current Range 0/4 to 20 mA (20 to 4/0 mA)

(2x) Galvanically separated

Open circuit and short-circuit proof

Maximum Burden 500 Ohm

Shown here is one product option. Other options have slightly different sockets and wiring.

Specifications Sheet May 2015 CSI 3120

www.emersonprocess.com/csi

Emerson Process ManagementReliability Solutions835 Innovation DriveKnoxville, TN 37932 USAT 1(865) 675-2400

©2015, Emerson Process Management. All rights reserved.

The Emerson logo is a trademark and service mark of Emerson Electric Co. Machinery Health is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners.

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.

Relay Out: Voltage UMAX: 48 VDC

(5x make contact) Current IMAX: 1 A

Contact Rating PMAX: 50 W

Ordering Information

Part Number Description

A3120/022-000 CSI 3120 Bearing-Vibration Monitor

Dimensions

A 3120/022-000

Specifications Sheet May 2015 CSI 3125

www.emersonprocess.com/csi

Bearing-Vibration MonitorEmerson’s Dual-Channel Bearing-Vibration Monitor is designed for small and low channel applications such as small steam, gas, and hydro turbines, and such as compressors, pumps, and fans to measure absolute bearing vibration signals. Measurement settings, alarms, and provided outputs are field configurable via software.

Measurement Performance

Sensor Input Type ICP Piezo-Electric Sensors

Measurement Range Freely selectable by means of configuration software according to the measuring range of the applied sensors

Linearity Error 0.2% at 25°C

Linearity Error, Calculated with Sensor <2.2% at 25°C

Output Stability as Function of Temperature

<0.08% / 10K

Long-Term Drift max. 1% of measuring range

Frequency Range: High-Pass Filter 5 to 5000 Hz

Low-Pass Filter 50 to 5000 Hz

Connection Type: “Harting” socket

Environmental

Shock Limit 20 g pk

Temperature Range -20 to 65°C (-4 to149°F)

Sealing IP65

Agency Ratings CE

Mechanical

Case Material / Weight Aluminum, stainless / ~1300 g (45.8 oz.)

Mounting Wall mount

Electrical

Supply Voltage Nominal +24 VDC

Permissible Voltage Range +18 to +31.2 VDC

Power Consumption max. 6 W

Buffered Out: Connection Available at Pins (Cage Terminal)

(2x) Voltage Range ±4.0 VDC

Accuracy ± 2.5%

Shown here is one product option. Other options have slightly different sockets and wiring.

Specifications Sheet May 2015 CSI 3125

2

Current Out: Current Range 0/4 to 20 mA (20 to 4/0 mA)

(2x) Galvanically separated

Open circuit and short-circuit proof

Maximum Burden 500 Ohm

Relay Out: Voltage UMAX: 48 VDC

(5x make contact) Current IMAX: 1 A

Contact Rating PMAX: 50 W

Ordering Information

Part Number Description

A3125/022-010 CSI 3125 Bearing-Vibration Monitor Vibration Acceleration (100mV / g 40g)

A3125/022-020 CSI 3125 Bearing-Vibration Monitor Vibration Velocity (100mV / in / s)

Dimensions

A 3125/022-0x0

Specifications Sheet May 2015 CSI 3125

www.emersonprocess.com/csi

Emerson Process ManagementReliability Solutions835 Innovation DriveKnoxville, TN 37932 USAT 1(865) 675-2400

©2015, Emerson Process Management. All rights reserved.

The Emerson logo is a trademark and service mark of Emerson Electric Co. Machinery Health is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners.

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.

Specifications Sheet May 2015 CSI 3210

www.emersonprocess.com/csi

Shaft-Position MonitorEmerson’s Dual-Channel Shaft-Position Monitor is designed for small and low channel applications such as small steam, gas, and hydro turbines, and such as compressors, pumps, and fans to measure relative shaft displacement signals. Measurement settings, alarms, and provided outputs are field configurable via software.

Measurement Performance

Sensor Input Type Eddy- Current Sensors

Measurement Range Freely selectable by means of configuration software according to the measuring range of the applied sensors

Frequency Range: Low-Pass Filter 10 Hz

Connection Type: Internal Converter “LEMO” socket

Environmental

Shock Limit 20 g pk

Temperature Range -20 to 65°C (-4 to149°F)

Sealing IP65

Agency Ratings CE

Mechanical

Case Material / Weight Aluminum, stainless / ~1300 g (45.8 oz.)

Mounting Wall mount

Electrical

Supply Voltage Nominal +24 VDC

Permissible Voltage Range +18 to +31.2 VDC

Power Consumption max. 6 W

Buffered Out: Connection Available at Pins (Cage Terminal)

(2x) Voltage Range 2.0 to 10.0 VDC

Accuracy ± 2.5%

Current Out: Current Range 0/4 to 20 mA (20 to 4/0 mA)

(2x) Galvanically separated

Open circuit and short-circuit proof

Maximum Burden 500 Ohm

Shown here is one product option. Other options have slightly different sockets and wiring.

Specifications Sheet May 2015 CSI 3210

2

Relay Out: Voltage UMAX: 48 VDC

(5x make contact) Current IMAX: 1 A

Contact Rating PMAX: 50 W

Ordering Information

Part Number Description

A3210/022-000 CSI 3210 Shaft-Position Monitor Eddy-Current Converters: INTERNAL

Dimensions

A 3210/022-000

Specifications Sheet May 2015 CSI 3210

www.emersonprocess.com/csi

Emerson Process ManagementReliability Solutions835 Innovation DriveKnoxville, TN 37932 USAT 1(865) 675-2400

©2015, Emerson Process Management. All rights reserved.

The Emerson logo is a trademark and service mark of Emerson Electric Co. Machinery Health is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners.

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.

Specifications Sheet May 2015 CSI 3311

www.emersonprocess.com/csi

Speed and Key MonitorEmerson’s Speed and Key Monitor is designed for small and low channel applications such as small steam, gas, and hydro turbines, and such as compressors, pumps, and fans to measure speed and generate key signals. Measurement settings, alarms, and provided outputs are field configurable via software.

Measurement Performance

Sensor Input Type Eddy- Current Sensors

Measurement Range Freely selectable by means of configuration software, max. 65535 rpm limited by input frequency

Linearity Error 0.25% at 25°C

Linearity Error, Calculated with Sensor Depending on sensor, max. -6% at 25°C

Output Stability as Function of Temperature

<0.08% / 10K

Long-Term Drift max. 1% of measuring range

Frequency Range 0 to 20 kHz Automatic setting of trigger level

Connection Type: Internal Converter “LEMO” socket

Environmental

Shock Limit 20 g pk

Temperature Range -20 to 65°C (-4 to149°F)

Sealing IP65

Agency Ratings CE

Mechanical

Case Material / Weight Aluminum, stainless / ~1300 g (45.8 oz.)

Mounting Wall mount

Electrical

Supply Voltage Nominal +24 VDC

Permissible Voltage Range +18 to +31.2 VDC

Power Consumption max. 6 W

Buffered Out: Connection Available at Pins (Cage Terminal)

(2x) Voltage Range 2.0 to 10.0 VDC

Accuracy ± 2.5%

Shown here is one product option. Other options have slightly different sockets and wiring.

Specifications Sheet May 2015 CSI 3311

2

Current Out: Current Range 0/4 to 20 mA (20 to 4/0 mA)

(2x) Galvanically separated

Open circuit and short-circuit proof

Maximum Burden 500 Ohm

Relay Out: Voltage UMAX: 48 VDC

(5x make contact) Current IMAX: 1 A

Contact Rating PMAX: 50 W

Ordering Information

Part Number Description

A3311/022-000 CSI 3110 Speed & Key Monitor Eddy-Current Converters: INTERNAL

Dimensions

A 3311/022-000

Specifications Sheet May 2015 CSI 3311

www.emersonprocess.com/csi

Emerson Process ManagementReliability Solutions835 Innovation DriveKnoxville, TN 37932 USAT 1(865) 675-2400

©2015, Emerson Process Management. All rights reserved.

The Emerson logo is a trademark and service mark of Emerson Electric Co. Machinery Health is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners.

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.