shelter outstation generic wiring diagram

1
LOCATION OF PROJECT NAME OF FACILITIES SUBJECT OF THE PROJECT KINGDOM OF SAUDI ARABIA General Authority of Civil Aviation Air Navigation Services 15 13 11 9 7 5 3 1 16 14 12 10 8 6 4 2 3 1 4 2 9 7 5 3 1 10 8 6 4 2 9 7 5 3 1 10 8 6 4 2 7 5 3 1 8 6 4 2 PL1 NON-ISOLATED DIGITAL INPUTS PL2 NON-ISOLATED DIGITAL OUTPUTS PL3 ANALOGUE INPUTS PL4 ISOLATED DIGITAL INPUTS PL6 SUPPLY V+ V- STONEFIELD RCM4000 SERIES OUTSTATION - 213-101 24V DC POWER SUPPLY V+ V- 12V 1.2Ah BATTERY (if fitted) DOOR MOUNTED KEYSWITCH Term PL9 - RS485 AB 4 3 2 1 N L WALL MOUNTED OUTSTATION ENCLOSURE 213-201 UNIT SELECT ACU 2 RUNNING ACU 1 RUNNING ACU PANEL - 3 x VOLT FREE CONTACTS -Ve +Ve Common NC NO IC SMOKE DETECTOR MAINS DISTRIBUTION PANEL CABLE MARSHALLING PANEL Junction Box fitted close to fuel Tank Connect Common (black) and N/C (grey) Installation cable colours and idents to be allocated by the Installation Engineers and recorded Serial RS485 comms must run as chain from PC to 1st outstation then to next outstation etc. On last outstation link "Term" (1) to "B" (2). For sites with Fibre connect single twisted pair to MOXA Nport INTRUDER DOOR SWITCH Cables shown dashed pre-installed by Stonefield Existing site cables between shelters Float Switch to be installed in fuel tank E Kingdom Wide Shelter Monitoring Remote Maintenance Monitoring Dave Gerrey David Lynd Stonefield Systems (Europe) Ltd Stable Cottage, Brook House Hammingden Lane Ardingly West Sussex, RH17 6SR United Kingdom +44 (0) 845 299 0096 www.stonefield.co.uk Twin Twisted Pair COMMS PAIR FROM PC OR PREVIOUS SHELTER COMMS PAIR TO NEXT SHELTER A B A A A B B B A B C D C D

Upload: sry-santos

Post on 18-Nov-2015

9 views

Category:

Documents


6 download

DESCRIPTION

wiring diagram

TRANSCRIPT

  • LOCATION OF PROJECTNAME OF FACILITIESSUBJECT OF THE PROJECT

    KINGDOM OF SAUDI ARABIA

    General Authority of Civil Aviation

    Air Navigation Services

    15 13 11 9 7 5 3 1

    16 14 12 10 8 6 4 2

    3 1

    4 2

    9 7 5 3 1

    10 8 6 4 2

    9 7 5 3 1

    10 8 6 4 2

    7 5 3 1

    8 6 4 2

    PL1NON-ISOLATEDDIGITAL INPUTS

    PL2NON-ISOLATED

    DIGITAL OUTPUTS

    PL3ANALOGUEINPUTS

    PL4ISOLATED

    DIGITAL INPUTS

    PL6SUPPLY

    V+ V-

    STONEFIELD RCM4000 SERIES OUTSTATION - 213-101

    24V DCPOWERSUPPLY

    V+ V-

    12V 1.2AhBATTERY(if fitted)

    DOORMOUNTEDKEYSWITCH

    Term

    PL9 - RS485

    A B4 3 2 1

    N L

    WALL MOUNTED OUTSTATION ENCLOSURE 213-201

    UNITSELECT

    ACU 2RUNNING

    ACU 1RUNNING

    ACU PANEL - 3 x VOLT FREE CONTACTS

    -Ve+VeCommonNCNOIC

    SMOKE DETECTOR

    MAINS DISTRIBUTIONPANEL

    CABLE MARSHALLINGPANEL

    Junction Box fitted closeto fuel TankConnect Common (black)and N/C (grey)

    Installation cable colours and identsto be allocated by the Installation

    Engineers and recorded

    Serial RS485 comms must run as chain from PC to 1st outstationthen to next outstation etc. On last outstation link "Term" (1) to "B" (2).

    For sites with Fibre connect single twisted pair to MOXA Nport

    INTRUDERDOOR SWITCH

    Cables shown dashedpre-installed byStonefield

    Existing site cables between shelters

    Float Switch to be installedin fuel tank

    E

    Kingdom WideShelter MonitoringRemote Maintenance Monitoring

    Dave Gerrey

    David Lynd

    Stonefield Systems (Europe) LtdStable Cottage, Brook HouseHammingden LaneArdinglyWest Sussex, RH17 6SRUnited Kingdom+44 (0) 845 299 0096www.stonefield.co.uk

    Twin Twisted Pair

    COMMS PAIR FROM PC OR PREVIOUS SHELTER

    COMMS PAIR TO NEXT SHELTER

    A

    B

    A A AB B B

    A BC D

    CD