shock, fire or explosion. inverter - home | daikin air...
TRANSCRIPT
PLXRHK1610
Cooling Only FTWK-A Series
InverterWall Mounted
Head Office:Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan.
Lot 60334, Persiaran Bukit Rahman Putra 3,Taman Perindustrian Bukit Rahman Putra,47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia.www.daikinmalaysia.com
DAIKIN MALAYSIA SDN. BHD.
DAIKIN INDUSTRIES, LTD.
DEALER
Specifications, designs and other content appearing in this brochure are current as of March 2016 but subject to change without notice. © All rights reserved.
Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
Read the User’s Manual carefully before using this product. The User’s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
Cautions on product corrosion1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Warning
Caution
If you have any enquiries, please contact your local importer, distributor and/or retailer.
OutdoorLightCompact &
Height: 420mm
Width: 765mm
Depth: 291mm
Weight: 24kg
Ergonomic handler position for transportation and installation.
Drain pan panel for effective water drainage.
“U-Shape base pan leg front eases installer in fixing unit
position.” Installer may fix the bolt before installing the unit.
Valve positioned at back top panel for easy servicing.
Easy access for wiring installation at back panel.
Drain hose located at lowest base point of outdoor to ensure
smooth water drainage.
Servicing Installation&Features
1 2
What is Invertertechnology?
Swing Compressor Advantages of Inverter technology
Low starting current
Reluctance DC motor for compressor
Inverter system ensures faster cooling with significant energy saving. Moreover, it helps to maintain consistent temperature in the room, makes you feel comfortable all the time especially when you are sleeping.
Daikin calls an inverter model that is equipped with a DC motor DC Inverter. A DC motor offers higher efficiency than an AC motor. A DC motor uses the power of magnets to attract and repel to generate rotation. A DC motor that is equipped with high-power neodynium magnets, which enables even greater efficiency, is called a Reluctance DC motor.
Thanks to its smooth rotation, the swing compressor decreases friction and vibration. It also prevents the leakage of refrigerant gas during compression. These advantages provide quiet and efficient operation.
Fixed speed (non-inverter) systems operate by compressor start-stop cycles which consumes more energy and have higher variance of the room temperature.
Taking the advantages of the ability to modulate the compressor speed, inverters are designed to operate with “soft start” feature. The compressor motor does not require high current during start up.
1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet.2. The torque created by the change in power between the iron and magnet parts.3. The frequency range used by air conditioners during periods of stable operation. This is the range in which air conditioners operate for the longest periods.
Neodymium magnets are used in the pink-coloured area.
Daikin DC Inverter models are equipped with the Reluctance DC motor for compressors. The Reluctance DC motor uses 2 different types of torque, neodymium magnet¹ and reluctance torque². This motor saves energy by generating more power with a smaller electric current than AC or conventional DC motors. It is more efficient at the low frequencies most commonly used by air conditioners³, improving efficiency by approximately 20%.
DC Inverter The swing compressor can reduceoperational vibration and sound because its piston moves smoothly inside the compressor.
LossLoss
SetTemperature
LossLoss
Uncomfortable(Energy Loss)
Uncomfortable(Energy Loss)
Comfortable
Daikin InverterSteady Temperature
Non InverterHigh Temperature
Flexible installation
Flexible performance, rapid response time
The extended piping length promotes flexible installation
After quickly reaching set temperature, the inverter system constantly adjusts and fine-tunes the cooling capacity to prevent undesired temperature swings. Room comfort level is constantly maintained even when the number of people in the room increases or decreases.
Note: Additional refrigerant is required if the piping is longer than the pre-charge length. For details, kindly refer to the installation manual.
ModelPre-
charge length
(m)
Max. length
(m)
Max. elevation
(m)
FTWK25AXV1HRWK25AXV1H 7.5 20 10
FTWK35AXV1HRWK35AXV1H 7.5 20 10
Precise & Stable Temperature ControlRoom
Temperature
SetTemperature
Time
Conventional SystemInverter System
Superior comfort Powerful operation Higher efficiency Better energy savings
3 4
Titanium Apatite Photocatalytic Air Purifying Filter Stylish Flat Panel
Micron-scale fibers trap dust while titanium apatite absorbs organic contaminants such as bacteria and viruses. In addition, the titanium oxide is activated by natural light, allowing it to break down and eliminate odours. The filter effectively deactivates bacteria and viruses. It lasts for three years without replacement if washed about once every six months.
An ideal blend of style and functionality. The front panel is designed for contemporary style without compromising on function. Air intake area is designed to ensure smooth air flow profile for better sound quality and optimized volume.
Lower Sound LevelWith up to five selectable fan speeds, users are given more choices. By selecting Quiet mode, the sound pressure level can be reduced down to an unobtrusive 21dBA.
Sleep ModePressing the Sleep button activates the Sleep Mode. This function prevents excessive cooling for a pleasant sleep.
Absorption power is more than doubled, dissolution force is increased.
• Photocatalytic deodorizing filter• Absorption of dangerous airborne particles like dust, pollen and cigarette smoke• Dissolves odour, bacteria and virus
• Mechanism of photocatalyst: - Titanium Oxide is activated by exposure to light - Becomes highly oxidative - Dissolves absorbed substances into harm less water(H2O) and carbon dioxide (CO2).
* This product is not a medical device, medical treatment device or therapeutic goods.* This product is not intended to have any therapeutic use or to be used for the diagnosis, treatment relief or prevention of illness.* If you have a health concern or are not feeling well, please consult a health care professional.
Cooling operation: 1) After 30 minutes, room temperature is raised by 0.5˚C.2) After 60 minutes, room temperature is raised by 0.5˚C.3) After 120 minutes, room temperature is raised by 1˚C.
Titanium Oxide
Time
Cooling
30mins
Sleep mode turns on
+
Set temp. before Sleep mode
begins to operate
++
30mins
60mins
20Rustling
of leaves 30Pendulum ofa wall clock 40
Library 50Normal office (dBA)
21dBA is so quiet you can even hear whispers
21dBAfor
FTWK25AXV1H; FTWK35AXV1H
5 6
Auto Random Restart with Last-State-Memory
Easy-to-use Wireless Remote Controller
Optional - Control System
In the event of a sudden power failure during operation, unit restarts automatically in 64 different recovery timing patterns (within 180 seconds to 244 seconds) and the unit will operate based on the previous setting (operating mode, temperature setting and fan speed). This ensures that air conditioners in the same building resume randomly instead of all units resuming at the same time, preventing power surge after a blackout.
Powerful OperationPowerful Operation is activated by pressing the Turbo button. Once activated, the air conditioner will run on full power with indoor fan running at maximum speed for 20 minutes. This enables the set temperature to be achieved faster. If Turbo and Sleep mode timer will be reset, it will resume after Turbo function is cleared.
Anti-Corrosion Hydrophilic Gold FinThe outdoor unit’s heat exchanger fins are constructed from anticorrosion hydrophilic gold fin. The anticorrosion fin increases the life span of the heat exchanger, especially when operating under corrosive and harsh environment.
20Rustling
of leaves 30Pendulum ofa wall clock 40
Library 50Normal office (dBA)
21dBA is so quiet you can even hear whispers
21dBAfor
FTWK25AXV1H; FTWK35AXV1H
E2 PROME2 PROM
RestartStopOperation
Power failure Power returns
Settings stored before power failure
“Glow-in-the-dark” On/Off switch
Quiet function
Off timer setting
Temperature setting: Up & down
Selectable Mode: Cool, Dry, Fan Fan speed selection: Low, Med, High, Auto
On timer setting
Real time clock
Vertical auto-swing
Sleep mode function
Turbo function
BRC52A62
Turbo function
Real time clock and day display
Delay timer (1 or 2 hours)
Swing function
7-days programmable timer
Cool, Dry, Fan mode
Temperature operate in ºC and ºF
Sleep functionLow, Med, High, Auto fan speed
Quiet function
On/Off switch
BRC51A62
T set
T room
Start 20min 30min
7 8
FTWK-AXV1H + RWK-AXV1H (Cooling only)
Specifications
Class 25/35
Note: 1. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB.2. Pre-charged refrigerant amount is based on standard pre-charged piping length of 7.5m.
Outdoor unit
Sound power level
3525
dB(A) 50/44 51/44
RWK-AXV1H
DimensionNet weight Pipe connection Liquid
Gas
R410A
Min. lengthPiping Max. length
mmkg
mmmm
mm
HxWxD
0.65Pre-charged refrigerant
kg
420x765x291 420x765x2912524
Ø9.52 Ø9.52Ø6.35 Ø6.35
0.90
2.5 2.520 20
Max. elevation m 10 10
Drain mm Ø19.05Ø19.05
Power supply Ph/V/Hz 1 phase, 220 V, 50 Hz (Power from Indoor) 1 phase, 220 V, 50 Hz (Power from Indoor)
Class 25/35comes with gold fin
3.20 (3.50-1.10)
4.87
8700 (9300-3300) 10900 (11900-3700)2.55 (2.75-0.98)
3.65
Efficiency Data 25 35
Cooling capacity MAX-MIN
Running current Cooling
Btu/hrkW
A
Cooling W
m
1040780Power consumption
7.57.5Pre-charged piping length
4.964.94CSPF
11Energy efficiency grading
Indoor unit FTWK-AXV1H378/345/272/215/165
42/41/34/30/22
25 35392/358/282/232/165
41/40/34/29/21Air flow T/H/M/L/Q
T/H/M/L/Qcfm
Sound power level dB(A)
9Titanium Apatite Photocatalytic Air Purifying Filter
288x859x209 288x859x2099
Dimension HxWxDNet weight
mm
Filter typekg
Function Dictionary
Vertical Auto-Swing (up and down)
Wide-Angle Louvers
wolfriA elbatrofmoC
The smoothly curved Wide-Angle Louvers provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room.
This function automatically moves the flaps up and down to distribute air across a room.
Indoor Unit On/Off Switch
Lifestyle Convenience
New Powerful OperationNew Powerful Operation boosts airflow to maximum volume for a 20-minute period. After this, the unit automatically returns to its previous settings.
The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged.
Sleep Mode
Timers
24-Hour On/Off TimerThis timer can be preset to start and stop at any time within a 24-hour period. The air conditioner is started/ stopped simply by pressing the On/Off timer button on the wireless remote controller.
Pressing the Sleep button activates the Sleep Mode. After 30 minutes, room temperature is raised by 0.5°C.After 60 minutes, room temperature is raised by 0.5°C.After 120 minutes, room temperature is raised by 1°C.
Washable Saranet Filter
Cleanliness
Wipe-Clean Flat Panel
Titanium Apatite Photocatalytic Air-Purifying FilterThis filter contains the new photocatalytic material titanium apatite. While the filter’s micron-level fibers trap dust, this photocatalyst absorbs and decomposes bacteria. The filter can be used for up to 3 years with proper maintenance.
Removal of airborne dust particles through saranet filter ensures cleaner air supply.
The flat panel models can be cleaned with only the single pass of a cloth across their smooth surface. The flat panel can also be easily removed for more thorough cleaning.
Auto Random Restart with Last-State-Memory
Worry Free
Self-Diagnosis
GOLDAnticorrosion Hydrophilic Gold Fin
BLINK
In the event of a sudden power failure during operation, unit restarts automatically in 64 different recovery timing patterns (within 180 seconds to 244 seconds) and the unit will operate based on the previous setting (operating mode, temperature setting and fan speed).
Malfunctioning of air conditioner unit by blinking of LED lights for fast and easy maintenance.
The outdoor unit’s heat exchanger fins are constructed from anticorrosion hydrophilic gold fin. The anticorrosion fin increases the life span of the heat exchanger, especially when operating under corrosive and harsh environment.
Indoor Unit Quiet Operation
lortnoC trofmoC
Programme Dry Function
Auto Fan Speed
Indoor unit operating sound levels are decreased by 3dB(A) from the Low setting fan speed using the wireless remote controller.
This function automatically reduces the level of humidity.
The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature.
9 10