short circuit protection (non-latch type) only for dc load...maximum 2.0 Ω within 1 s load short...
TRANSCRIPT
ASCTB28E 202009Panasonic Corporation 2020
FEATURESProtects Circuit from excess currentNo need for fuses, poly switches, or other protectorsHigh capacityCan control up to 0.5A (60V DC) load current.
Short circuit protection (Non-latch type) only for DC loadGU 1 Form A Short Circuit Protection non-latch type
PhotoMOS
TYPICAL APPLICATIONSIndustrial equipmentSecurity equipment
Note: Please contact our sales representative for automotive applications of PhotoMOS.
8.8 6.46.4
3.6
8.8
3.9
1
3
2
4
6
5
+
-
(Height includes standoff)
(Unit: mm)
TYPES
Category
Output rating*1 Part No. Packing quantity
Load voltage
Load current
Through holeterminal Surface mount terminal
Tube Tape and reelTube packing style Tape and reel
packing style X*2Tape and reel
packing style Z*2
DC only 60 V 500 mA AQV112KL AQV112KLA AQV112KLAX AQV112KLAZ 1-tube: 50 pcs.Outer carton: 500 pcs.
1-reel: 1,000 pcs.Outer carton: 1,000 pcs.
Note: The surface mount terminal shape indicator “A” and the packing style indicator “X” or “Z” are not marked on the device. (Ex. the label for product number AQV112KLAX is AQV112KL.)
*1.Indicate the DC values.*2.Tape and reel packing style X: picked from the 1/2/3-pin side, tape and reel packing style Z: picked from the 4/5/6-pin side.
Absolute maximum ratings (Ambient temperature: 25°C)Item Symbol AQV112KL (A) Remarks
Inpu
t
LED forward current IF 50 mALED reverse voltage VR 5 V
Peak forward current IFP 1 A f = 100 Hz, Duty Ratio = 0.1%
Power dissipation Pin 75 mW
Out
put Load voltage (peak AC) VL 7 to 60V
Continuous load current IL 0.5 A Peak AC, DCPower dissipation Pout 500 mW
Total power dissipation PT 550 mWI/O isolation voltage Viso 1,500 VrmsAmbient temperature (Operating) Topr -40 to +85°C (Avoid icing and
condensation)Ambient temperature (Storage) Tstg -40 to +100°C
RATING
industrial.panasonic.com/ac/e/2020.09 ー 1 ー
PhotoMOS GU 1 Form A Short Circuit Protection
Panasonic Corporation Electromechanical Control Business Divisionindustrial.panasonic.com/ac/e/ ASCTB28E 202009Panasonic Corporation 2020
90%
10%
Input
Output
ToffTon
*2. Turn on/Turn off time
Recommended operating conditions (Ambient temperature: 25°C)Please use under recommended operating conditions to obtain expected characteristics.
Item Symbol Min. Max. UnitLED current IF 10 30 mA
AQV112KL (A)Load voltage (DC) VL 10 48 VContinuous load current(DC) IL - 0.5 A
Electrical characteristics (Ambient temperature: 25°C)Item Symbol AQV112KL (A) Condition
Inpu
t
LED operate current
TypicalIFon
0.8 mAIL = 100 mA
Maximum 10 mA
LED turn off current
MinimumIFoff
0.3 mAIL = 100 mA
Typical 0.7 mA
LED dropout voltage
TypicalVF
1.35 V (1.17 V at IF = 10 mA)IF = 50 mA
Maximum 1.5 V
Out
put
On resistanceTypical
Ron
0.55 Ω IF = 10 mA IL = Max.Within 1 sMaximum 2.0 Ω
Load short circuit detection voltage*1
TypicalVLSHT
5 VIF = 10 mA
Maximum 7 VOff state leakagecurrent Maximum ILeak 1 μA IF = 0 mA
VL = Max.
Tran
sfer
cha
ract
eris
tics Turn on time*2
TypicalTon
2.0 ms IF = 10 mAIL = 100 mA VL = 10 VMaximum 5.0 ms
Turn off time*2Typical
Toff
0.1 ms IF = 10 mAIL = 100 mA VL = 10 VMaximum 1.0 ms
I/O capacitanceTypical
Ciso0.8 pF f = 1 MHz
VB = 0 VMaximum 1.5 pFInitial I/O isolationresistance Minimum Riso 1,000 MΩ 500 V DC
*1. At IF = 10mA, load current will be oscillated if the voltage between 4 (+) -6 (-) terminals becomes more than the delection voltage of the short circuit.
ー 2 ー
PhotoMOS GU 1 Form A Short Circuit Protection
Panasonic Corporation Electromechanical Control Business Divisionindustrial.panasonic.com/ac/e/ ASCTB28E 202009Panasonic Corporation 2020
REFERENCE DATA
1. Load current vs. ambient temperature characteristics
-400
300
200
100
400
500
600
-20 0 20 40 60 80 10085
Load
cur
rent
(mA)
Ambient temperature (°C)
Allowable ambient temperature: –40 to +85°C
2. On resistance vs. ambient temperature characteristics
-400
0.5
1.0
1.5
2.0
-20 0 20 40 60 8085
On
resi
stan
ce (Ω
)
Ambient temperature (°C)
Measured portion: between terminals 4 and 6;LED current: 10 mA; Load current: Max. (DC)
3. Turn on time vs. ambient temperature characteristics
-400
2
1
3
4
5
-20 0 20 40 60 80 85
Turn
on
time
(ms)
Ambient temperature (°C)
Measured portion: between terminals 4 and 6;LED current: 10 mA; Load voltage: 10 V (DC);Load current: 100 mA
4. Turn off time vs. ambient temperature characteristics
-400
0.10
0.05
0.15
0.20
0.25
0.30
-20 0 20 40 60 8085
Turn
off
tim
e (m
s)
Ambient temperature (°C)
Measured portion: between terminals 4 and 6;LED current: 10 mA; Load voltage: 10 V (DC);Load current: 100 mA (DC)
5. LED operate current vs. ambient temperature characteristics
-400
1.0
0.5
1.5
2.0
2.5
3.0
-20 0 20 40 60 80 85
LED
ope
rate
cur
rent
(mA)
Ambient temperature (°C)
Measured portion: between terminals 4 and 6;Load current: 100 mA
6. LED turn off current vs. ambient temperature characteristics
-400
1.0
0.5
1.5
2.0
2.5
3.0
-20 0 20 40 60 8085
LED
turn
off
cur
rent
(mA)
Ambient temperature (°C)
Measured portion: between terminals 4 and 6;Load current: 100 mA
7. Off state leakage current vs. load voltage characteristics
0
10-11
10-12
10-9
10-10
10-8
10-6
10-7
10 20 30 5040 60Load voltage (V)
Off
sta
te le
akag
e cu
rren
t (A)
Measured portion: between terminals 4 and 6;Ambient temperature: 25°C
8. Current vs. voltage characteristics of output at MOS portion
-1.0
-0.6
0.6
0.4
0.2
0
-0.2
-0.4
-0.5 0 0.5 1.0Voltage (V)
Curr
ent (
A)
Measured portion: between terminals 4 and 6;Ambient temperature: 25°C
9. LED dropout voltage vs. ambient temperature characteristics
50 mA
30 mA
20 mA
10 mA
-401.0
1.1
1.2
1.3
1.4
1.5
-20 0 20 40 60 80 85Ambient temperature (°C)
LED
dro
pout
vol
tage
(V)
Measured portion: between terminals 1 and 2;LED current: 10 to 50 mA
ー 3 ー
PhotoMOS GU 1 Form A Short Circuit Protection
Panasonic Corporation Electromechanical Control Business Divisionindustrial.panasonic.com/ac/e/ ASCTB28E 202009Panasonic Corporation 2020
13. Short circuit peak current vs. time characteristics
01
1.5
2.0
2.5
3.0
3.5
4.0
10 20 30 40 50 60
VL = 24 VVL = 24 V
VL = 12 VVL = 12 V
VL = 60 VVL = 60 V
Shor
t circ
uit p
eak
curr
ent (
A)
Time (S)
Measured portion: between terminals 4 and 6;LED current: 10 mA; Load resistance: 0 Ω;Ambient temperature: 25°C
14. Short current monitoring interval vs. time characteristics
0
5
10
30
25
20
15
10 20 30 40 50 60
VL = 60 VVL = 60 V
VL = 24 VVL = 24 V
VL = 12 VVL = 12 V
0
Shor
t cur
rent
mon
itorin
g in
terv
al (m
s)
Time (S)
Measured portion: between terminals 4 and 6;LED current: 10 mA; Load resistance: 0 Ω;Ambient temperature: 25°C
10. Turn on time vs. LED forward current characteristics
0-1
1
0
2
3
4
5
10 20 30 40 50LED forward current (mA)
Turn
on
time
(ms)
Measured portion: between terminals 4 and 6;Load voltage: 10 V (DC); Load current: 100 mA (DC);Ambient temperature: 25°C
11. Turn off time vs. LED forward current characteristics
00
0.05
0.10
0.15
0.20
10 20 30 40 50LED forward current (mA)
Turn
off
tim
e (m
s)
Measured portion: between terminals 4 and 6;Load voltage: 10 V (DC); Load current: 100 mA (DC);Ambient temperature: 25°C
12. Output capacitance vs. applied voltage characteristics
00
200
100
300
400
500
10 20 30 40 50 60Applied voltage (V)
Out
put c
apac
itanc
e (p
F)
Measured portion: between terminals 4 and 6;Frequency: 1 MHz; Ambient temperature: 25°C
What is short circuit protection Non-latch type?
If the load current reaches a predetermined overcurrent level, the output-side short circuit protection function cuts off the load current. It then monitors the load current, and if it returns to normal, automatically recovers to normal device operation.In order to operate the short circuit protection function, ensure that the input current is at least IF = 10 mA.
Operation chart (Non-latch type)
Input Current
Output Current
①Load short detected
②Function operation
③Load turn off③Load turn off
ー 4 ー
PhotoMOS GU 1 Form A Short Circuit Protection
Panasonic Corporation Electromechanical Control Business Divisionindustrial.panasonic.com/ac/e/ ASCTB28E 202009Panasonic Corporation 2020
7.
62±
0 .05
±0 .
056 .
4
±0.058.8 3.4
±0 .
23 .
9
0.47 0.47
1.25
2.54 2.54
1.25
3
1.25
0.47
Max.10°
Max.10°
Terminal thickness: t = 0.25General tolerance: ±0.1
8.8±0.05
6.4±
0 .05
7 .6
3.4
1
3.4
0.47 0.470.47
1.251.25 1.25
2.54 2.54
0.2+0
.2ー0
Max.10°
Terminal thickness: t = 0.25General tolerance: ±0.1
5.08 2.546-0.8 dia.
2.54
7 .626 .4
Tolerance: ±0.1
8 .3
1 .9
1.5
2.542.54
Tolerance: ±0.1
CAD Through hole terminal typeExternal dimensions
DIMENSIONS CAD The CAD data of the products with a “CAD” mark can be downloaded from our Website. Unit: mm
PC board pattern(Bottom view)
Recommended mounting pad(Top view)
Surface mount terminal typeExternal dimensions
CAD
Please refer to "the latest product specifications"when designing your product.•Requests to customers:https://industrial.panasonic.com/ac/e/salespolicies/
SAFETY STANDARDS
Part No.UL (Recognized) CSA (Certified)
RemarksFile No. (Standard No.) Contact rating File No.
(Standard No.) Contact rating
AC/DC dual use AQV112KL (A) E191218 (UL1577) 0.5A 60V DC (Certified by C-UL) VDE approved
(Nr. 40051981)
Note: For the latest information on compliance with safety standards, please refer to our website.
SCHEMATIC AND WIRING DIAGRAMS
Schematic Outputconfiguration
Load type Connection Wiring diagram
+
-1
3
2
4
6
5
*
1 Form A DC A
1
E1IL
2
3
6
5
4VL (DC) IL
6
4VL (DC)
+ +
IF
Load
Load
*Terminal 3 cannot be used, since it is in the internal circuit of the device.
ー 5 ー
Please contact ..........
Electromechanical Control Business Division
industral.panasonic.com/ac/e/
Specifications are subject to change without notice.
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan
©Panasonic Corporation 2020
ASCTB28E 202009