short-range wakes in elliptical pipe geometry

26
Short-Range Wakes in Elliptical Pipe Geometry Igor Zagorodnov Beam Dynamics Group Meeting 05.09.05

Upload: deo

Post on 18-Jan-2016

27 views

Category:

Documents


3 download

DESCRIPTION

Short-Range Wakes in Elliptical Pipe Geometry. Igor Zagorodnov Beam Dynamics Group Meeting 05.09.05. Pumping slot. Theoretical results (Bethe theory) only for. Pumping slot. Effect of the slot is small. Accuracy estimation of the numerical results. Wake scaling for geometry parameters. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Short-Range Wakes in Elliptical Pipe Geometry

Short-Range Wakes in Elliptical Pipe Geometry

Igor Zagorodnov

Beam Dynamics Group Meeting

05.09.05

Page 2: Short-Range Wakes in Elliptical Pipe Geometry

1w mm width of the slot 5L m length of the slot

Pumping slot

25w m

Theoretical results (Bethe theory) only for .w

Page 3: Short-Range Wakes in Elliptical Pipe Geometry

Pumping slot

Effect of the slot is small.

•Accuracy estimation of the numerical results.•Wake scaling for geometry parameters.

Used tools: ECHO (time-domain), CST Microwave Studio (modeling, meshing), Matlab (pre- and postprocessing).

Page 4: Short-Range Wakes in Elliptical Pipe Geometry

0 lnhi

Z bZ

a 2

hiloss

z

Z ck

250 m

25 m

1( ln( / ))lossk O b a

37.2 /lossk V pC

372 /lossk V pC

in outW W W

Out In

2( ) /(2 )L b a

ba

Page 5: Short-Range Wakes in Elliptical Pipe Geometry

[m]

dx

[dy,dz

[Loss,2D

[V/pC]

Error, 2D

[V/pC]

Loss, 3D

[V/pC]

Error, 3D

[V/pC]

250 1/40 1/40 36.3097 ref.

250 1/20 1/20 36.2932 0.016

250 1/5 1/5 36.2369 0.07 36.2265 0.1

25 1/20 1/20 370.77 ref.

25 1/10 1/10 370.60 0.17

25 1/5 1/5 369.96 0.8

25 1/5 2 369.78 1

outlossk

1( ln( / ))outlossk O b a

Accuracy of 3D calculations

Page 6: Short-Range Wakes in Elliptical Pipe Geometry

-5 0 5-15

-10

-5

0

5x 10-3

out V mW

pC

/s

250 m

25 m

1( )outW O

Page 7: Short-Range Wakes in Elliptical Pipe Geometry

[m]

dx

[dy,dz

[Loss,2D

[V/pC]

Error, 2D

[V/pC]

Loss, 3D

[V/pC]

Error, 3D

[V/pC]

250 1/40 1/40 -0.8606 ref.

250 1/10 1/10 -0.8678 0.001

250 1/5 1/5 -0.8802 0.012 -0.8478 0.013

25 1/20 1/20 0.8639 ref.

25 1/10 1/10 -0.8619 0.002

25 1/5 1/5 -0.8859 0.02

25 1/5 2 -0.9380 0.17

inlossk

1( )inlossk O a

in outloss lossk k

Accuracy of 3D calculations

Page 8: Short-Range Wakes in Elliptical Pipe Geometry

-5 0 50

0.5

1

1.5

2in V

WpC

/s

250

(3 )

m

D

(1), 0inW O

25

(3 )

m

D

25

(2 )

m

D

Page 9: Short-Range Wakes in Elliptical Pipe Geometry

1 lnoutloss

bk O

a

1inlossk O

a

Scaling laws

Out In

2( ) /(2 )L b a

ba

Page 10: Short-Range Wakes in Elliptical Pipe Geometry

( )w

1 lnoutloss

bk O

a

inlossk O

a

, ?

Scaling laws

w

a

b

Page 11: Short-Range Wakes in Elliptical Pipe Geometry

w10h mm

4a mm

Out In

Page 12: Short-Range Wakes in Elliptical Pipe Geometry

w10h mm

4a mm

w

[mm]

[m]

Loss

[V/pC]

7 0.339 250 3.04+-0.1

4 0.167 250 0.91+-0.1

2 0.083 250 0.23+-0.1

7 0.339 25 31.8+-1

4 0.167 25

2 0.083 25 2.8+-1

outlossk

1( )outlossk O

1.8( ) ?!outlossk O

w

Page 13: Short-Range Wakes in Elliptical Pipe Geometry

-5 0 5-1.5

-1

-0.5

0

0.51.8 1.8

outW V

pC rad

/s

0.3392

1.8( ), 0,outW O w

0.1672

0.0832

250 m

Page 14: Short-Range Wakes in Elliptical Pipe Geometry

w10h mm

4a mm

w

[mm]

[m]

Loss

[V/pC]

7 0.339 250 -0.162+-0.013

4 0.167 250 -0.065+-0.013

2 0.083 250 -0.01+-0.013

7 0.339 25 -0.247+-0.17

4 0.167 25

2 0.083 25

inlossk

( ) ?!inlossk O

(1), 0inlossk O

in outloss lossk k

w

Page 15: Short-Range Wakes in Elliptical Pipe Geometry

-5 0 5-0.05

0

0.05

0.1

0.15

0.2inW V

pC rad

/s

0.3392

( ), 0,inW O w

0.1672

0.0832

250 m

?error

Page 16: Short-Range Wakes in Elliptical Pipe Geometry

w

1 1.8 lnoutloss

bk O

a

inlossk O

a

w

[mm]

a,

[mm]

[m]

Loss

[V/pC]

7 4 0.339 250 -0.16

1 7.5 0.021 25 -0.005

0.021 40.16 0.005

0.339 7.5inloss

Vk

pC

w

[mm]

b,

[mm]

a,

[mm]

[m]

Loss

[V/pC]

7 10 4 0.339 250 3

1 20 7.5 0.021 25 0.2

1.820

ln0.021 7.5

3 10 0.2100.339

ln4

outloss

Vk

pC

0.2loss

Vk

pC

Scaling laws and extrapolation

Page 17: Short-Range Wakes in Elliptical Pipe Geometry

in outW W W 2out in eW W W

2 2 2 , 0in e e inW W W W if W

in outloss lossk k

( )ez ellipse ellipse slot zW w w w

(K. Zotter et al. , Impedances and Wakes …, 1998 andK.L.F.Bane, I.A.Zagorodnov, SLAC-PUB-11388, 2005)

w

Energy method

Page 18: Short-Range Wakes in Elliptical Pipe Geometry

w

[mm]

[m]K_loss from time-domain

[V/pC]

K_loss from energy

[V/pC]

Error,

[V/pC]

7 250 2.88 3.10 0.22

7 25 31.5 31.0 0.5

2 250 0.22 0.26 0.04

2 25 2.75 2.63 0.12

Accuracy of the energy method

Page 19: Short-Range Wakes in Elliptical Pipe Geometry

[mm] Mesh step in

Ellipse Ellipse with slot

0.25 2 2.89161337 2.89165659 4.32e-5

0.25 1 2.90553777 2.90560728 6.95e-5

0

2w

Z c

0.03 0.12 /lossk V pC

, 0.001 /kick xk V pC( , 0, 0)

( , 0, 0)s

yx

W s x yW s x y ds

a

xy

xa

20h mm

2 2 5000 25 3 16 [ ]h L e mm

0.2 /lossk V pC

Energy method

Page 20: Short-Range Wakes in Elliptical Pipe Geometry

3mm

3.3mm3.8mm

84 248 257 /loss s sk x y V pC

, 390 46 436 /kick x s wk x x x V pC

, 348 47 301 /kick y s wk y y y V pC

Energy method

85 /lossk V pC

Round (a=3.8, b=3.3)

0.5mm

15mm

3mm

7.6yw mm

2 351 /( )Dkickk V pC m

3 359 /( )Dkickk V pC m

Direct time-domain with ECHO

x

y

9yw mm

7.8yw mm 85 /lossk V pC

91 /lossk V pC

Old pipe?

The energy loss for the new smaller pipe is a little smaller!

2%Error

Page 21: Short-Range Wakes in Elliptical Pipe Geometry

x

y0.5mm

15mm

3mm

7.6 mm

250 250 /84loss s sk x y V pC

, 390 46 /436kick x s wk x x x V pC

, 348 47 /301kick y s wk y y y V pC

1200 1200 /42loss s sk x y V pC

, 280 206 /486kick x s wk x x x V pC

, 78 208 /130kick y s wk y y y V pC

Loss,

V/pC

Spread,

V/pC

Peak,

V/pC

var1 84 33 -118

var2 42 16 -58

Page 22: Short-Range Wakes in Elliptical Pipe Geometry

x

yKick

, /486kick xk x V pC

, /130kick yk y V pC

xy

xa

, 0.001 /slotkick xk V pC

, ,0.0001 0.01 /slot abskick x kick xk k V pC

Page 23: Short-Range Wakes in Elliptical Pipe Geometry

pro section (6.1 m)

Loss,

V/pC

Spread,

V/pC

Peak,

V/pC

absorber 1 42 16 -58

pumping slot 1 <0.2 <0.1 >-0.3

pump 1 9 4 -13

BPM 1

bellow 1 13 5 -18

flange gap 1 6 2.4 -8.5

Total geom. 70 25 -95

resistive (Cu) 6.1m 220 279 -542

resistive (Al) 6.1m 303 325 -660

Longitudinal wake for the case of the elliptical pipe (3.8mm)

Page 24: Short-Range Wakes in Elliptical Pipe Geometry

-5 0 5

-300

-200

-100

0

100

200

300

-5 0 5-300

-200

-100

0

100

200

300

Shape dependence

-5 0 50

1000

2000

3000

4000

5000

Loss,

V/pC

Spread,

V/pC

Peak,

V/pC

Gauss, cu/al 36/50 46/53 -89/108

Rect, cu/al 79/93 90/72 -256/243

-1 -1: 5.8e+7[ m ], =2.46e-14[sec]cond relaxcu -1 -1: 3.66e+7[ m ], =7.1e-15[sec]cond relaxal

copper aluminum

I A

VW

pC

VW

pC

/ zs

/ zs / zs

25z m

Page 25: Short-Range Wakes in Elliptical Pipe Geometry

4000 [ ]bN bunches

10 [ ]repf Hz

1[ ]q nC

2b rep lossP N f q k

0.52geom

WP

m

, 1.4res Cu

WP

m

, 2res Al

WP

m

Power Loss (Gaussian bunch)

Page 26: Short-Range Wakes in Elliptical Pipe Geometry

Conclusion

• Loss and kick of the pumping slot are negligible • Wake of the absorber is reduced by factor 2• Resistive wake is dominant• Non-smooth bunch shape (rectangular) increases

the energy spread less than by factor 2