siemens 3000 nova
TRANSCRIPT
-
Siemens-Elema ABSE-171 95 Solna, SwedenTel: +46-8-730-7473E-mail: [email protected]: http://SiemensMedical.com/mammo
Please contact your localSiemens representative for moreinformation on MAMMOMAT3000 Nova and other top-qualitysystems for Womens Health.
Siemens reserves the right tomodify the design and specifica-tions contained herein withoutprior notice.
Art.nr. 65 79 994Order No. A91003-M1270-B02-4A00Printed in Sweden WS1101
Siemens Has Your Answers
MAMMOMAT 3000 Nova clinical solutions are multi-purpose, reliable, and full of high-performance features.The system provides excellent return on investmentand is scalable to suit all environments from the privateclinic to the multi-department institution. Siemens alsoprotects your investment MAMMOMAT 3000 Nova isupgradeable at any time.
-
sBecause she deserves the very bestMAMMOMAT 3000 Nova
-
2
-
3Whether we are captivated by internationalbreast cancer statistics or touched by thepersonal experiences of our own patients, itis clear that breast care challenges are diverseand numerous.
Your breast care systems must enable you tohandle your patients' needs with confidence,speed and efficiency from screening anddiagnosis through therapy. MAMMOMAT
3000 Nova, an anchor system in Siemensspectrum of breast care solutions, expandsthe MAMMOMAT legacy by offering
screening, diagnostic work-up, andstereotactic biopsy capabilities in a singleunit.
MAMMOMAT 3000 Nova is a high perfor-mance, reliable mammography system. It ispatient- and user-friendly, and yields thehighest quality images. If your goal is toaccurately diagnose breast disease in itsearliest, most treatable stages, then youcouldn't have a better partner than Siemens -- or a more versatile mammography systemthan MAMMOMAT 3000 Nova.
Partners in Womens Health Care
-
4MAMMOMAT 3000 Nova offers themost versatile technology for breastimaging and biopsy guidance. Itsopen design, integrated features, andwork-horse reliability ensure thehighest performance.
Because it is a screening unit, diagnosticwork-up system and stereotactic biopsyunit all in one, MAMMOMAT 3000Nova maximizes system utilizationpotential, return on investment andspace savings. Imagine the efficiencyof using one system for:
Screening
Special Views
Magnification
Stereotactic biopsy, fine needle and core
Needle localization
Specimen radiography
Stereotactic biopsy can be performedwith the patient in a comfortablesitting or recumbent position. Thesystem accommodates biopsybetween +120 and 165, in steps of15.
With the functions of a dedicated biopsy system and the versatility tohandle all mammography procedures,MAMMOMAT 3000 Nova is aninvestment which pays for itself, overand over again.
One system for all procedures from screening through interventional diagnostics
Mammogram, mlo view
Stereotactic biopsy, patient seated
Stereotactic biopsy, patient recumbent
-
5Siemens engineers added newdesign elements, softer linesand a fresh look for MAMMOMAT3000 Nova, while preservingthe highly-appreciated featuresand options of our provenM3000.
Superior AccessibilityThe slim tube-head design andnarrow base allows easy, properpositioning of patients, includingthose in wheelchairs. Excellentergonomic conditions are pre-served for both operator andpatient, even during biopsy procedures.
IsocentricityMotorized isocentric movementoffers precision and time-savingswhen positioning patients.Because the swivel arm movesisocentrically, the object tableremains at the proper heightbetween projections. Change
between angle settings everyangle from cc to the inverted180 without readjusting theheight.
Pivoting BuckysThe unique dual Bucky designenables quick and easyswitching between 18x24 and24x30 cm formats. When theobject table is changed, the appropriate collimation automa-tically pre-selects. Additionally,either object table can bemanually replaced with the stereotactic device or magni-fication table.
Generous gantry free-spaceThe 65-cm gantry opening (SID)allows easy patient positioningand accommodates popularbiopsy devices. For example,the minimally-invasive vacuum-assisted Mammotome corebiopsy system can be mounted
in the vertical position in the stereotactic device in linewith the direction of compressionfor the shortest distance andgreatest accuracy in reachingthe lesion.
Ergonomic design and handling patient-friendly and user-friendly
-
6Advanced features in an advanced system
Women used to complainabout uncomfortable traditionalmammography. Now there isOpcomp optimized compression. This exclusiveSiemens feature, standard on
MAMMOMAT 3000 Nova, senses breast thickness andcompressibility. It compressesas long as the breast is soft andpliable, then stops preciselywhen image quality is maximized.
Opcomp spares your patient unnecessary discomfort, andensures consistent and repro-ducible compression technique.
Opdose Optimized doseMo/Mo, Mo/Rh, W/Rh
Siemens invented the dual-trackX-ray tube, with Molybdenumand Tungsten anode materialsin 1994, and it has gainedpopularity with every installation.The Opdose system auto-selects the best anode/filtercombination (Mo/Mo, Mo/Rh,W/Rh), and the lowest dose,according to individual breastcharacteristics. This is particularlyimportant for younger womenwhose breasts normally havehigher density and often requirehigher dose. By selecting W/Rhin appropriate cases, Opdosecan save up to 60% dose over acomparable Mo/Mo exposure.
Opcomp is easy tooperate - when theoptimal value isreached, the green in-dicator light on thefloor display is activa-ted, and the systemis ready for exposure.
Opcomp Optimized Compression No More, No Less
-
7GeneratorHigh-voltage wave form: MultipulseExposure voltage: 23kV to 35kV, adjustable in increments of 1kVmAs range: Mo X-ray tube: 2mAs to 560 mAs (mAs-mode)
up to 600mAs (AEC-mode)Mo/W X-ray tube: 2mAs to 710 mAs (mAs-mode)up to 752 mAs (AEC-mode)
Exposure times: From 10 ms to 4sFrom 10 ms to 7s for magnification technique
Automatic exposure controlAutomatic exposure control (AEC): Microprocessor controlled, transparency compensationDetectors: Semi conductor detectorAccuracy of optical density (2-6 cm): 0.15 OD from the mean optical density for predefined film-
screen combinations (separately for each grid table, magnification table and anode-filter combination at appropriate clinical kV).
Density correction: 3 exposure points, adjustable in 1/8 step incrementsFilm-screen combinations: 2; User selectable on the generator control panel (H/D).
X-ray tube assemblyX-ray tube (Mo resp. Mo/W): Molybdenum/Tungsten rotating anode tube with Beryllium window,
P40 Mo/W four focus tube with nominal focal spot value 0.1/0.3 (star pattern), 0.15/0.3 (DIN/IEC 336/1993)
Tube current (Mo resp. Mo/W): Molybdenum max. large focal spot: 150 mA at 25 kV, max. small focal spot: 28 mA at 25 kV. Tungsten max. large focal spot. 188 mA at 25 kV, max. small focal spot 34 mA at 25 kV.
Total heat storage capacity: 1 100 00 Joule (1 500 00 HU)(IEC 613/1989)Anode heat storage capacity: 120 000 Joule (162 000 HU)(IEC 613/1989)Anode speed: 8 800 r.p.m.Filter: Mo tube : 30m Molybdenum, 25m Rhodium
Mo/W tube: 30m Molybdenum, 25m Rhodium, 50m Rhodium
X-ray standHeight adjustment: Motorized, 650 mm to 1350 mm floor to object table (in all angles) Swivel range: +135 / -180Rotation of swivel arm: Motorized, isocentricSource to Image Distance (SID): 65 cmFilm formats: 18cm x 24cm, 24cm x 30cm (15 mm thick Mammography
cassettes according to DIN 6832/IEC 406). Automatic collimation to film format
Grid: Reciprocating; Pb 4/27 (4:1 ratio, 27 lines/cm) Compression device: Opcomp, motorized compression initiated via footswitch or
manual adjustment
Technical specificationsMAMMOMAT 3000 Nova
-
8Compression force: Maximum motorized force 200NMagnification technique: Factor of 1.5 and 1.8Power supply: 110V, 208V, 230V, 240V, 277V, 10%, 1-phase; 208V, 230V,
277V, 400V 10%, 2-phase; 50 Hz or 60 HzFuse: 35A at 110V
20A at 208V to 400V
Stereotactic biopsy deviceAccuracy for 100mm: x,y,z 1.0 mmNeedle position in steps: 0.1 mmBiopsy field size: 58 x 40 mmCompression opening: 0-140 mmAccommodates needle lengths: from 30mm to 175mmNeedle holders: 0.7mm (22G), 0.9mm (20G), 1.2mm (18G), 1.65mm (16G)
2.1mm (14G), 2.5mm ( 13G), Open needle holders (localization): 0.9mm (20G), 1.2mm (18G)Film size: 18cm x 24cmCassettes: DIN 6832 / IEC 406 (15mm thickness)Weight, biopsy unit: 12 kgWeight, evaluation unit: 12 kg
Installation InformationX-ray stand including base plate: 300 kgGenerator with control console and radiation shield: 141 kg, 0.3mm Pb Eq.Free standing radiation shield 46 kg, 0.1mm alt. 0.3mm Pb Eq.
-
Digital imaging has manyadvantages over film post-processing, image enhancement,better workflow and moreefficient image transfer/archivaland retrieval processes. Butbecause of its very high require-ments for image quality, resolu-tion and viewing, mammo-graphy has been called thelast modality to go digital. Aguaranteed upgrade path ensu-res that your investment todayis secure MAMMOMAT 3000and MAMMOMAT 3000 Novaare the platforms for futuredigital technology.
9
A platform for the digital future
As the gold standard, Opdima
offers the industry's largestfield of view (49x85mm) andsuperior detector resolution foroptimum clinical utility and imagequality. Near real-time displaysends the image quickly to theworkstation for post-processing,diagnosis, target-setting, etc.With substantial time-savingsversus film, Opdima meanshigher patient throughput andimproved patient tolerance.The upgradeable MAMMOMAT3000 Nova can be configuredwith Opdima initially or addedlater.
MAMMOMAT 3000 Nova with Opdima
FFDM Full-Field Digital Mammography
OpdimaDigital biopsy and spot imaging