SYSTEM DATA SHEET Sikalastic®-624 WP Waterproofing System LIQUID APPLIED ALKALINE-RESISTANT SINGLE COMPONENT FULLY REINFORCED SYSTEM WITH FIBERGLASS OR POLYESTER REINFORCEMENT PRODUCT DESCRIPTION Sikalastic®-624 WP Waterproofing System combine a cold applied, aliphatic, single component, alkali resistant, moisture-triggered polyurethane resin with fiberglass mat or polyester fleece reinforcement to create a seam- less membrane and flashing system. Typical applications include a separate wearing course (overlayment or over- burden), but Sikalastic®-624 WP Waterproofing System is UV resistant without protection board and is there- fore suitable for direct exposure waterproofing applica- tions as well. System components are: Sika® or Sikalastic® Primer: Select primer per substrate material in accordance with Priming Guide Sikalastic®-624 WP: Resin used for all systems with Sika Reemat or Sika Fleece reinforcements Sikalastic® Reemat Premium: Chopped strand fiberglass mat Sika® Fleece 120, 140, 170: Non-woven, needle-punched polyester fleece in various weights USES Sikalastic®-624 WP Waterproofing System may only be used by experienced professionals. Sikalastic® waterproofing systems, including Sikalastic® Plaza Deck/PMA and Vegetated systems for both new construction and refurbishment Split-slab waterproofing - between slabs Vegetated deck waterproofing Plaza decks with concrete pavers, and asphalt or con- crete paving stones in a sand bed Waterproofing under tile in a mortar bed Applications involving cementitious and asphalt pave- ment overlays Waterproofing around/beneath mechanical equipment CHARACTERISTICS / ADVANTAGES Proven technology with over 30 year track record Single component - no mixing and ready to use Fully reinforced with highly conformable Sika® Reemat or Sika® Fleece Integrated flashings utilizing same resin and reinforce- ments Ideal for complex details and geometry or when access- ibility is limited Moisture triggered chemistry that is rapidly weather- proof after application Highly elastic and crack bridging Seamless and fully adhered Vapor permeable UV resistant and non-yellowing Abrasion and chemical resistant Alkali resistant formulation Adheres to most common construction materials when suitable primer is used. APPROVALS / STANDARDS Miami Dade County approved: NOA No.: 15-0113.01 Meets ASTM C836 Standard Specification for High Solids Content, Cold Liquid-Applied Elastomeric Water- proofing Membrane for Use with Separate Wearing Course. Meets ASTM E-108-00 Spread of Flame: Class A at slope of 1:12 System Data Sheet Sikalastic®-624 WP Waterproofing System May 2018, Version 01.01 020915909000000015 1 / 9

Upload: others

Post on 28-Dec-2019

11 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Sikalastic®-624 WP Waterproofing System · cold applied, aliphatic, single component, alkali resistant, moisture-triggered polyurethane resin with fiberglass mat or polyester fleece

SYSTEM DATA SHEETSikalastic®-624 WP Waterproofing SystemLIQUID APPLIED ALKALINE-RESISTANT SINGLE COMPONENT FULLY REINFORCED SYSTEM WITHFIBERGLASS OR POLYESTER REINFORCEMENT

PRODUCT DESCRIPTIONSikalastic®-624 WP Waterproofing System combine acold applied, aliphatic, single component, alkali resistant,moisture-triggered polyurethane resin with fiberglassmat or polyester fleece reinforcement to create a seam-less membrane and flashing system. Typical applicationsinclude a separate wearing course (overlayment or over-burden), but Sikalastic®-624 WP Waterproofing Systemis UV resistant without protection board and is there-fore suitable for direct exposure waterproofing applica-tions as well. System components are: Sika® or Sikalastic® Primer: Select primer per substratematerial in accordance with Priming GuideSikalastic®-624 WP: Resin used for all systems with SikaReemat or Sika Fleece reinforcementsSikalastic® Reemat Premium: Chopped strand fiberglassmatSika® Fleece 120, 140, 170: Non-woven, needle-punchedpolyester fleece in various weights

USESSikalastic®-624 WP Waterproofing System may only beused by experienced professionals.

Sikalastic® waterproofing systems, including Sikalastic®Plaza Deck/PMA and Vegetated systems for both newconstruction and refurbishment

Split-slab waterproofing - between slabs▪Vegetated deck waterproofing▪Plaza decks with concrete pavers, and asphalt or con-crete paving stones in a sand bed

Waterproofing under tile in a mortar bed▪Applications involving cementitious and asphalt pave-ment overlays

Waterproofing around/beneath mechanical equipment▪

CHARACTERISTICS / ADVANTAGESProven technology with over 30 year track record▪Single component - no mixing and ready to use▪Fully reinforced with highly conformable Sika® Reemator Sika® Fleece

Integrated flashings utilizing same resin and reinforce-ments

Ideal for complex details and geometry or when access-ibility is limited

Moisture triggered chemistry that is rapidly weather-proof after application

Highly elastic and crack bridging▪Seamless and fully adhered▪Vapor permeable▪UV resistant and non-yellowing▪Abrasion and chemical resistant▪Alkali resistant formulation▪Adheres to most common construction materials whensuitable primer is used.

APPROVALS / STANDARDSMiami Dade County approved: NOA No.: 15-0113.01▪Meets ASTM C836 Standard Specification for HighSolids Content, Cold Liquid-Applied Elastomeric Water-proofing Membrane for Use with Separate WearingCourse.

Meets ASTM E-108-00 Spread of Flame: Class A at slopeof 1:12

System Data SheetSikalastic®-624 WP Waterproofing SystemMay 2018, Version 01.01020915909000000015

1 / 9

Page 2: Sikalastic®-624 WP Waterproofing System · cold applied, aliphatic, single component, alkali resistant, moisture-triggered polyurethane resin with fiberglass mat or polyester fleece

SYSTEM INFORMATIONSystem Structure Sikalastic® RoofPro WP System Guide with Sika® Reemat

RoofPro 15 WP* RoofPro 20 WP* RoofPro 25 WP*

1. Primer See PrimingGuide

See PrimingGuide

See PrimingGuide

2. Base Layer:Sikalastic®-624-WP

45 mils wet35 sf/gal.

45 mils wet35 sf/gal.

45 mils wet35 sf/gal.

3. Reinforcement: Sika® ReematPremium

Sika® ReematPremium

Sika® ReematPremium

4. Top Layer:Sikalastic®-624-WP

30 mils wet53 sf/gal.

40 mils wet40 sf/gal.

30 mils wet53 sf/gal.

5. Top Layer:Sikalastic®-624-WP

- - 30 mils wet53 sf/gal.

Sikalastic® RoofPro WP System Guide with Sika® Fleece

RoofPro 15 WP* RoofPro 20 WP* RoofPro 25 WP*

1. Primer See PrimingGuide

See PrimingGuide

See PrimingGuide

2. Base Layer:Sikalastic®-624-WP

45 mils wet35 sf/gal.

50 mils wet32 sf/gal.

65 mils wet24 sf/gal.

3. Reinforcement: Sika® Fleece120 (US)

Sika® Fleece140 (US)

Sika® Fleece170 (US)

4. Top Layer:Sikalastic®-624-WP

25 mils wet64 sf/gal.

35 mils wet45 sf/gal.

40 mils wet40 sf/gal.

* Substrates: Concrete or cementious, metals, woods, single-ply or bituminous, stone. Primer required (seeSubstrate Priming Guide). Detailing: Sika® Flexitape Heavy centered over seams, transitions and properlytreated cracks and joints. Note: Coverage rates provided are optimal and are not guaranteed - cover-age rates will vary depending on temperature, surface roughness and poros-ity, aggregate selection and embedment, and application technique.

Chemical base Moisture triggered Polyurethane

Colour White, Pearl Gray

System Data SheetSikalastic®-624 WP Waterproofing SystemMay 2018, Version 01.01020915909000000015

2 / 9

Page 3: Sikalastic®-624 WP Waterproofing System · cold applied, aliphatic, single component, alkali resistant, moisture-triggered polyurethane resin with fiberglass mat or polyester fleece

Dry film thickness Sikalastic® RoofPro WP System Guide with Sika® ReematRoofPro 15 RoofPro 20 WP RoofPro 25 WP53 mils dry 60 mils dry 75 mils dry

Sikalastic® RoofPro WP System Guide with Sika® FleeceRoofPro 15 WP RoofPro 20 WP RoofPro 25 WP50 mils dry 60 mils dry 75 mils dry

Note: Coverage rates provided are optimal and are not guaranteed - cover-age rates will vary depending on temperature, surface roughness and poros-ity, aggregate selection and embedment, and application technique.

TECHNICAL INFORMATIONTensile Strength Sikalastic® WP 20 with

Sika® Reemat PremiumSikalastic® WP 20 withSika® Fleece 140

2450 psi 1100 psi

(ASTM D-751 Proc. B)

Note: Data for other WP assemblies available upon request

Elongation at Break Sikalastic® WP 20 withSika® Reemat Premium

Sikalastic® WP 20 withSika® Fleece 140

10 % 78 %

(ASTM D-751)

Note: Data for other WP assemblies available upon request

Tear Strength Sikalastic® WP 20 withSika® Reemat Premium

Sikalastic® WP 20 withSika® Fleece 140

430 lbf/in 300 lbf/in

(ASTM D-624)

Note: Data for other WP assemblies available upon request

Resistance to Static Puncture Sikalastic® WP 20 withSika® Reemat Premium

Sikalastic® WP 20 withSika® Fleece 140

>55 lbf >55 lbf

(ASTM D-5602)

Note: Data for other WP assemblies available upon request

Reaction to Fire Class A (ASTM E 108)

Chemical Resistance Strong resistance to a wide range of reagents, including paraffin, petrol, fueloil, white spirit, acid rain, detergents and moderate solutions of acids and al-kalis. Some low molecular weight alcohols can soften the material. ContactTechnical Service for specific recomendations. Salt spray to ASTM B117 (1000hours continuous exposure) and prohesion testing to ASTM G85-94: Annex A5(1000 hours cyclic exposure)

Solar Reflectance 86.8 % (ASTM C-1549) (White)

Thermal Emittance 0.87 (ASTM C-1371) (White)

Solar Reflectance Index 109 (ASTM E-1980) (White)

Service Temperature -22–176 °F (-30–80 °C) intermittent

System Data SheetSikalastic®-624 WP Waterproofing SystemMay 2018, Version 01.01020915909000000015

3 / 9

Page 4: Sikalastic®-624 WP Waterproofing System · cold applied, aliphatic, single component, alkali resistant, moisture-triggered polyurethane resin with fiberglass mat or polyester fleece

APPLICATION INFORMATIONAmbient Air Temperature 41 °F (5 °C) min. / 95 °F (35 °C) max

Relative Air Humidity 80 % R.H. max.

Substrate Temperature 41 °F (5 °C) min. / 140°F (60°C) max.

Dew Point Beware of condensation.The substrate and uncured coating must be ≥ 5 °F (3 °C) above dew point.

Substrate Moisture Content ≤ 4 % moisture content Test method: Sika®-Tramex meterNo rising moisture according to ASTM (Polyethylene-sheet)

Substrate Pre-Treatment Refer to Priming Guide to select primer for properly evaluated and preparedsubstrate. Refer to separate primer Product Data Sheet for for applicationmethods, coverage rates, cure times and recoat windows. Always allowprimer to cure thoroughly before applying detail or base resin layer. Sikalastic®-624 WP Waterproofing System Priming GuideSubstrate Primer optionsConcrete1 Sikalastic® Concrete Primer Lo-VOC

Sika® Concrete PrimerSika® Bonding PrimerSikalastic® DTE PrimerSikalastic® EP Primer/Sealer

Lightweight concrete*1 Sikalastic® Concrete Primer Lo-VOCSika® Concrete PrimerSikalastic® DTE Primer

Brick, stone*3 Sikalastic® Concrete Primer Lo-VOCSika® Concrete PrimerSikalastic® EP Primer/SealerSika® Bonding Primer

Bituminous substrate-asphalt, bituminous felts, bitumin-ous coatings, granulated or smoothSBS & APP cap sheets2,3

Sikalastic® EP Primer/Sealer

Roof tiles (unglazed)*3,4 Sika® Bonding PrimerSikalastic® EP Primer/Sealer

Metal-aluminium, galvanized, cast iron,copper, lead, brass, stainless steel,steel, zinc3

Sikalastic® EP Primer/Sealer

Pre-coated metal*3 -Paints & Coatings-paints & coatings*3

-aluminized solar reflective coatings3

-Sikalastic® EP Primer/Sealer

Wood - Timber & plywood*5 Bonding PrimerSikalastic® EP Primer/Sealer

* Consult Sika1 New cementitious substrates must be Portland based and be cured min. 28 days.2 The presence of volatiles may cause discoloration of Sikalastic® if not properly primed.3 Surface evaluation and field adhesion testing.4 Glazed tile consult Sika.5 Pressure treated lumber consult Sika.

System Data SheetSikalastic®-624 WP Waterproofing SystemMay 2018, Version 01.01020915909000000015

4 / 9

Page 5: Sikalastic®-624 WP Waterproofing System · cold applied, aliphatic, single component, alkali resistant, moisture-triggered polyurethane resin with fiberglass mat or polyester fleece

Waiting Time / Overcoating Ambient conditions Minimum waiting time overcoating+40 °F / 50 % r.h. 14 hours+50 °F / 50 % r.h. 6 hours+70 °F / 50 % r.h. 5 hours

*After 7 days the surface must be cleaned and primed with Sika® Reactiva-tion Primer before continuing.Note: Times are approximate and will be affected by changing ambient condi-tions particularly temperature and relative humidity.

Applied Product Ready for Use Ambient condi-tions

Rain resistant Touch dry Full cure

+40 °F / 50 % r.h. 10 min. 12 hours 24 hours+50 °F / 50 % r.h. 10 min. 6 hours 18–24 hours+70 °F / 50 % r.h. 10 min. 4 hours 12–18 hours

Note: Times are approximate and will be affected by changing ambient condi-tions particularly temperature and relative humidity.

PRODUCT INFORMATIONPackaging 5 gal. (18.9 L) pails

Shelf Life 9 months in original, unopened and undamaged sealed containers

Storage Conditions Store dry at 35–77 °F (2–25 °C). Condition material to 50–77 °F (10–25 °C) be-fore using for ease of application

APPLICATION INSTRUCTIONSSUBSTRATE PREPARATION

Substrate EvaluationConcrete and cementitious substratesNew concrete shall be allowed to cure a minimum of 28days. Concrete shall have a minimum compressivestrength of 20.7 MPa (3000 psi) and exhibit a minimumtensile bond strength of 1.4 MPa (200 psi). time. Moistor sheet curing methods should be used, as opposed tothe use of curing compounds, which may interfere withthe bond of the membrane. Inspect the concrete, includ-ing upstands, and all areas should be hammer tested.Concrete must be suitably finished, preferably by woodfloat or steel pan. A power float finish is acceptablewhere the surface is prepared to avoid laitance (atamped finish is not acceptable). The surface finish mustbe uniform and free from defects such as laitance, voidsor honeycombing. Gypsum and Cement based sheathingSheathing boards shall be clean, dry and dust free, andshall be properly secured to the structure. Loose, dam-aged, or contaminated boards shall be removed and re-placed. Brick and stoneMortar joints must be sound and preferably flush poin-ted.AsphaltAsphalt contains volatiles which can cause bleeding and

slight non-detrimental staining. The asphalt must becarefully assessed for moisture and/or air entrapment,grade and surface finish. Bituminous feltEnsure that bituminous felt is firmly adhered or mechan-ically fixed to the substrate. Bituminous felt shall notcontain badly degraded areas.Bituminous coatingsBituminous coatings shall not have sticky or mobile sur-faces, volatile mastic coatings, or old coal tar coatings. MetalsMetals must be in sound condition. Wooden substratesPlywood and timber based roof decks must be in goodcondition, firmly adhered and mechanically fixed. All ply-wood should be identified as conforming to PS 1 for con-struction and industrial plywood by grade, APA (Americ-an Plywood Association) trademark, or equivalent. Formaximum smoothness, EXT Type APA, Grade A-C shouldbe used, and the “A” side should be positioned to re-ceive the Sikalastic® resin. Plywood decks to receive res-in directly shall be at least 1/2'' thick and attached andsupported according to APA guidelines, using only non-rusting screw, spiral or coated nail type fasteners. Agood practice would be to recess or counter sink fasten-ers 1/8 to 1/4'' and fill with Sikaflex® sealant. Suitableedge support to prevent differential deflection betweenpanels shall be provided. Panel edges shall be tongueand groove or supported on solid blocking. Space panels

System Data SheetSikalastic®-624 WP Waterproofing SystemMay 2018, Version 01.01020915909000000015

5 / 9

Page 6: Sikalastic®-624 WP Waterproofing System · cold applied, aliphatic, single component, alkali resistant, moisture-triggered polyurethane resin with fiberglass mat or polyester fleece

1/8 to 3/16'' at panel ends. Paints and coatingsEnsure the existing material is sound and firmly adhered. Existing Sikalastic® SystemThe existing Sikalastic® System shall be soundly adheredto the substrate. Surface PreparationConcrete and cementitious substratesCementitious or mineral based substrates must be pre-pared mechanically using abrasive blast cleaning or scari-fying equipment to remove cement laitance and toachieve an open textured surface (CSP 3-5 per ICRIguidelines). Loose friable material and weak concretemust be completely removed and surface defects suchas blowholes and voids must be fully exposed. Theamount of embedment coat required may increase overrough or highly porous surfaces.Repairs to the substrate, filling of joints, blowholes/voidsand surface levelling must be carried out. Consult Sikafor product recommendations based on project require-ments. High spots must be removed by grinding or simil-ar method. Outgassing is a naturally occurring phe-nomenon of concrete that can produce pinholes in li-quid applied materials. The concrete must be carefullyassessed for moisture content, air entrapment, and sur-face finish prior to any roofing work. Particular require-ments for priming must also be considered. Installing theprimer and membrane either when the concrete tem-perature is falling or stable can reduce outgassing. It isgenerally beneficial, therefore, to apply the primer andembedment coat in the late afternoon or evening. Gypsum and Cement based sheathingSheathing boards shall be clean, dry and dust free. Se-cure loose boards if in sound condition. Damaged or con-taminated boards shall be removed and replaced. Brick and stonePower wash and use biodegradeable non-sudsing deter-gent with clean water rinse as required. AsphaltPower wash and use biodegradeable non-sudsing deter-gent with clean water rinse as required. All major cracksshould be sealed to allow continuity of the Sikalastic®system. Bituminous feltPower wash and use biodegradeable non-sudsing deter-gent with clean water rinse as required. Treat blisters bystar cutting and removing any underlying water. Allow todry and re-adhere using suitable adhesive. Bituminous coatingsRemove any loose or degraded coatings.

MetalsFerrous metals should be thoroughly cleaned by grind-ing or blast cleaning prior to priming (SSPC-SP3 to near-white metal). Non-ferrous metals are prepared by re-moving any deposits of dust and oxidation and abradingto bright metal. Wire brushing can be used for soft met-al such as lead. The surface must be clean and free fromgrease which, if present, must be removed with asolvent wipe or wash with detergent, rinse and dry. Wooden substratesTimber and timber based roof decks require additionalreinforcement such as the installation of plywood, ap-proved insulation or cover board. Small timber protru-sions and suitable decks may be treated directly,provided that the timber is of exterior quality, e.g. ply-wood. Fill joints flush with Sikaflex® sealant.Paints/CoatingsRemove any loose or degraded coatings. Ensure the sur-face is clean and free from grease. Sikaplan®/Sarnafil® membranesClean membranes with Sarna® Cleaner (PVC mem-branes) and Sarnafil® T Clean (TPO membranes) prior toapplication of primer. Existing Sikalastic® SystemsClean the membrane using a water jet at approximately140 bar (2000 psi) and biodegradeable non-sudsing de-tergent with clean water rinse. Allow todry.

MIXING

No mixing necessary

APPLICATION

DetailingNon-structural cracks up to 1/16''- Detail application notnecessary. Apply embedment/base resin layer per be-low. Non-structural cracks between 1/16 inch and 1/4 inch -Rout and seal with Sikaflex® sealant. Apply 40-45 mil res-in layer embedded with 3 inch Sika® Flexitape Heavycentered over crack. Alternativly Sika® Joint Tape SA canbe applied. Apply embedment/base resin layer per be-low. Cracks and joints between 1/4 ' and 1''- Rout and sealwith Sikaflex® sealant. Apply bond breaker tape suffi-cient to span width of crack or joint followed by 40-45mil resin layer embedded with 6'' Sika® Flexitape Heavycentered over crack or joint. Apply embedment/baseresin layer by terminating Sika® Reemat or Sika® Fleeceat edges of crack or joint overlapping Sika® FlexitapeHeavy a minimum of 2 inches on both sides. Joints greater than 1''- Treat as expansion joint. Consult

System Data SheetSikalastic®-624 WP Waterproofing SystemMay 2018, Version 01.01020915909000000015

6 / 9

Page 7: Sikalastic®-624 WP Waterproofing System · cold applied, aliphatic, single component, alkali resistant, moisture-triggered polyurethane resin with fiberglass mat or polyester fleece

Sika for recommendations. Metal seams and plywood/coverboard joints - Apply40–45 mil resin layer embedded with 3 or 6'' Sika® Flex-itape Heavy centered over seam. Alternativly Sika® JointTape SA can be applied. Apply embedment resin layerper below. Transitions between dissimilar materials - Apply 40–45mil resin layer embedded with Sika® Flexitape Heavycentered over edge. Apply embedment resin layer perbelow. Embedment/Base Resin Layer with Sika® Reemat Rein-forcementMixing not required. Apply Sikalastic®-624 WP Water-proofing System Guide at the coverage rate in the ARSystem Guide with a 1/2'' nap phenolic resin core roller.Material can also be squeegee or spray applied, in whichcase it should be backrolled prior to embedding Sika®Reemat. Place Sika® Reemat in wet base resin layer over-lapping seams a minimum of 2'' (place frayed edge overcut edge of roll) and apply wet roller to topside to satur-ate completely. After approximately 5 minutes the bind-er will begin to dissolve allowing the fiber strands to con-form to irregular surfaces. Do not over work once thefibers have conformed to the substrate. Allow to cure 12hours at 70 °F and 50 % R.H. or until tack free before topresin layer. Keep clean and dry and apply top resin layerwithin 7 days. If window is exceeded clean with non-sudsing detergent and clean water rinse, and allow todry prior to application of Sika® Reactivation Primer. Top Resin Layer with Sika® Reemat ReinforcementMixing not required. Apply Sikalastic®- 624-WP-Water-proofing at the coverage rate in the RoofPro SystemGuide with a 1/2'' nap phenolic resin core roller. Materi-al can also be squeegee or spray applied, in which case itshould also be backrolled. In the case of RoofPro 25 al-low the first top resin layer to cure 12 hours at 70 °F and50 % R.H. or until tack free before applying second topresin layer. On top of the complete RoofPro system addi-tional resin layers may be applied with aggregate for slipresistance - consult Sika for recommendations. Keepclean and dry and apply additional resin layers within 7days. If window is exceeded clean with non-sudsing de-tergent and clean water rinse, and allow to dry prior toapplication of Sika® Reactivation Primer. Wet on Wet Application with Sika® Fleece Reinforce-mentMixing not required. To primed substrate apply two-thirds of the Sikalastic®- 624-WP-Waterproofing spe-cified in the WP System Guide with a 1/2'' nap phenolicresin core roller. Immediately place specified Sika®Fleece into wet resin overlapping seams a minimum of3” along the edge and 6” end-to-end. Apply wet roller totopside with light pressure to saturate fleece from bot-tom and ensure air pockets are completely removed. Im-mediately apply all of remaining one-third of Sikalastic®-

624-WP-Waterproofing resin specified in the WP SystemGuide to ensure even and complete fleece saturationfrom topside and uniform texture. Overburden ApplicationSikalastic®-624-WP-Waterproofing membrane may beused as the waterproofing layer under a wide range ofoverburden materials. Depending on the overburdentype, different surfacing, drainage, and protection layersmay be required. Protected Membrane AssembliesInstall Sika® 420 Drain Mat over the Sikalastic®-624-WP-Waterproofing membrane prior to the installation of theextruded polystyrene insulation layer. No aggregatedmembrane surfacing is required. Concrete Pavers with Pedestal SupportsInstall Sika® 420 Drain Mat over the Sikalastic®-624-WP-Waterproofing membrane to provide additional protec-tion of the membrane under the pedestal supports. Tile Adhered in a Cementitious Thin-Set AdhesiveA full aggregate broadcast surfacing is required toprovide an adhesion key for the tile adhesive. Apply asupplemental 15 wet mils of Sikalastic®-624-WP-Water-proofing resin, followed by a full broadcast of 16–30 or12–20 kiln-dried sand to refusal, typically 40–50 lbs./100sf. Remove all loose sand once resin has cured. Do notseal the aggregated surface. Tile in a Cementitious Setting BedInstall Sika 720 Drain Mat over the Sikalastic®-624-WP-Waterproofing membrane prior to installation of the ce-mentitious setting bed, which is typically 1–1/2”-3” inthickness, and which may be sloped to create positivedrainage. Secure the Sika® 720 Drain Mat to the Sikalast-ic®-624-WP-Waterproofing membrane as required toprevent shifting during setting bed installation by spot-adhering with Sikaflex® 11 FC. Bi-level drains should beinstalled to provide drainage capability at the mem-brane level as well as drainage of the finished surface. Concrete/Asphalt Pavers in a Sand Setting BedInstall Sika® 420 Drain Mat over the Sikalastic®-624-WP-Waterproofing membrane prior to installation of thesand setting bed, which is typically either graded silicasand or a mix of sand and asphalt. Secure the Sika® 420Drain Mat to the Sikalastic®-624-WP-Waterproofingmembrane as required to prevent shifting during settingbed installation by spot-adhering with Sikaflex® 11 FC.Bi-level drains should be installed to provide drainagecapability at the membrane level as well as drainage ofthe finished surface. Vegetation and Growing Media/SoilThe selection of a vegetated overburden assembly is typ-ically project specific and specified by a qualified designprofessional. At a minimum, install Sika® GRS Drain Matover the Sikalastic®-624-WP-Waterproofing membrane

System Data SheetSikalastic®-624 WP Waterproofing SystemMay 2018, Version 01.01020915909000000015

7 / 9

Page 8: Sikalastic®-624 WP Waterproofing System · cold applied, aliphatic, single component, alkali resistant, moisture-triggered polyurethane resin with fiberglass mat or polyester fleece

prior to application of all other overburden components.Secure the Sika® GRS Drain Mat to the Sikalastic®-624-WP-Waterproofing membrane as required to preventshifting during vegetative overburden assembly compon-ents by spot-adhering with Sikaflex® 11 FC. Bi-leveldrains should be installed to provide drainage capabilityat the membrane level as well as drainage at grade level. Concrete PavementInstall Sika® 1000 Drain Mat over the Sikalastic®-624-WP-Waterproofing membrane prior to application of thefresh concrete. Secure the Sika® 1000 Drain Mat to theSikalastic®-624-WP-Waterproofing membrane as re-quired to prevent shifting during concrete placement byspot-adhering with Sikaflex® 11 FC. Bi-level drains shouldbe installed to provide drainage capability at the mem-brane level as well as drainage of the finished surface. Asphalt PavementInstall Sika® 1000 Drain Mat over the Sikalastic®-624-WP-Waterproofing membrane, followed by the installa-tion of a ¼” thick asphalt protection board. Overlap theprotection board at all end and side laps by 2” min. Se-cure the Sika® 1000 Drain Mat and asphalt protectionboard as required to prevent shifting during asphaltpavement placement by spot-adhering with Sikaflex® 11FC. Bi-level drains should be installed to provide drain-age capability at the membrane level as well as drainageof the finished surface.

CLEANING OF TOOLS

Clean all tools and application equipment with appropri-ate solvent immediately after use. Hardened and/orcured material can only be removed mechanically

LIMITATIONSMinimum age of concrete must be 28 days dependingon curing and drying conditions.

Do not thin with solvents.▪Do not store materials outdoors exposed to sunlightand moisture for prolonged periods.

Do not apply to substrate surfaces where moisture va-por transmission will occur during application and cure.This condition may be checked using ASTM D-4263(Polyethylene Sheet method).

Substrate must be dry prior to application. Do not ap-ply to a frosted, wet or damp surface.

Allow sufficient time for the substrate to dry after rainor inclement weather, as there is the potential forbonding problems.

On substrates likely to exhibit outgassing apply duringfalling ambient and substrate temperature.

If applied during rising temperature pinholing may oc-cur.

Use sunglasses with UV filter when applying highly re-flective white resins.

Do not use for indoor applications.▪Precautions should be taken to prevent vapors and/or▪

odors from entering the building/ structure, includingbut not limited to turning off and sealing air intakevents and throughwallair conditioners, and othermeans of vapor/odor ingress during application andcure.For areas with direct exposure to heavy or frequentfoot traffic, an additional wear coat protection with slipresistant aggregate is required. Opening to traffic priorto cure may result in loss of aggregate or permanentstaining and subsequent premature failure.

Any repairs required to achieve a level surface must beperformed prior to application (consult a Sika repres-entative for guidance on various product solutions).Surface irregularities may reflect through the cured sys-tem.

When applying over existing coatings or membranescompatibility and adhesion testing, and subsequent ap-proval by Technical Services is required.

Opening to traffic prior to cure may result in loss of ag-gregate or permanent staining and subsequent prema-ture failure

On grade concrete decks should not be covered withSikalastic® RoofPro membrane systems.

Unvented metal pan, split/sandwich slab with encapsu-lated membrane and/or insulation, cinder fill decks,and lightweight insulating concrete overlays should notbe covered with

Sikalastic® RoofPro membrane systems without addi-tional deck evaluation and subsequent approval byTechnical Services.

Do not subject to continuous immersion.▪Not recommended for use over ceramic tile.▪

.

BASIS OF PRODUCT DATAResults may differ based upon statistical variations de-pending upon mixing methods and equipment, temper-ature, application methods, test methods, actual siteconditions and curing conditions.

LOCAL RESTRICTIONSPrior to each use of any Sika product, the user must al-ways read and follow the warnings and instructions onthe product’s most current Product Data Sheet, productlabel and Safety Data Sheet which are available online athttp://usa.sika.com/ or by calling Sika's Technical Ser-vice Department at 800.933.7452 nothing contained inany Sika materials relieves the user of the obligation toread and follow the warnings and instructions for eachSika product for each Sika product as set forth in the cur-rent Product Data Sheet, product label and Safety DataSheet prior to product use.

ECOLOGY, HEALTH AND SAFETYKeep container tightly closed. Keep out of reach of chil-dren. Not for internal consumption. For industrial useonly. For professional use only. For further information

System Data SheetSikalastic®-624 WP Waterproofing SystemMay 2018, Version 01.01020915909000000015

8 / 9

Page 9: Sikalastic®-624 WP Waterproofing System · cold applied, aliphatic, single component, alkali resistant, moisture-triggered polyurethane resin with fiberglass mat or polyester fleece

and advice regarding transportation, handling, storageand disposal of chemical products, users should refer tothe actual Safety Data Sheets containing physical, ecolo-gical, toxicological and other safety related data. Readthe current actual Safety Data Sheet before using theproduct. In case of emergency, call CHEMTREC at 1-800-424-9300, International 703-527-3887.

LEGAL NOTESPrior to each use of any Sika product, the user must al-ways read and follow the warnings and instructions onthe product’s most current Product Data Sheet, productlabel and Safety Data Sheet which are available online athttp://usa.sika.com/ or by calling Sika’s Technical Ser-vice Department at 800-933-7452. Nothing contained inany Sika materials relieves the user of the obligation toread and follow the warnings and instruction for eachSika product as set forth in the current Product DataSheet, product label and Safety Data Sheet prior toproduct use. SIKA warrants this product for one yearfrom date of installation to be free from manufacturingdefects and to meet the technical properties on the cur-rent Product Data Sheet if used as directed within shelflife. User determines suitability of product for intendeduse and assumes all risks. Buyer’s sole remedy shall belimited to the purchase price or replacement of productexclusive of labor or cost of labor. No other warrantiesexpress or implied shall apply including any warranty ofmerchantability or fitness for a particular purpose. Sikashall not be liable under any legal theory for special orconsequential damages. Sika shall not be responsible forthe use of this product in a manner to infringe on anypatent or any other intellectual property rights held byothers. Sale of Sika products are subject to Sika's termsand conditions of sale available at http://usa.sika.com/or by calling 201-933-8800.

Sikalastic-624WPWaterproofingSystem-en-US-(05-2018)-1-1.pdf

Sika Corporation201 Polito AvenueLyndhurst, NJ 07071Phone: 800-933-7452Fax: 201-933-6225

Sika Canada Inc.601 Delmar AvenuePointe ClaireQuebec H9R 4A9Phone: 514-697-2610Fax: 514-694-2792

Sika Mexicana S.A. de C.V.Carretera Libre Celaya Km. 8.5Fracc. Industrial BalvaneraCorregidora, QueretaroC.P. 76920Phone: 52 442 2385800Fax: 52 442 2250537

System Data SheetSikalastic®-624 WP Waterproofing SystemMay 2018, Version 01.01020915909000000015

9 / 9