simplified liquid extraction faster. easier. reliable. sle ......simplified liquid extraction n o vu...
TRANSCRIPT
novumsimplified liquid extraction
Faster. Easier. Reliable. SLE Simplified.
Need Ultra-Low Detection Limits? Move Over Biotage® ISOLUTE® SLE+. Meet New Novum PRO.
www.phenomenex.com/Novum
PATENT PENDING
novumsimplified liquid extraction
novumsimplified liquid extraction
novumsimplified liquid extraction
novumsimplified liquid extraction
Rev
isio
n:
PH
EN
-RU
O-0
0132
0
Phenomenex l WEB: www.phenomenex.com2
Your Diatomaceous Earth SLE Product Could Use Some ImprovementsThe material inside your SLE product consists of diatomaceous earth (fossilized diatoms) that is extremely old and can make extractions unreliable.
© 2021 Phenomenex, Inc. All rights reserved.
All diatoms are unique, making each of your traditional SLE products unique and therefore inconsistent.
Diatomaceous earth can be found in various mines across the world. Do you know where each batch of your SLE media comes from?
1000x zoom of salt water vs. fresh water diatomaceous
earth sorbents
2
Phenomenex l WEB: www.phenomenex.com
Redefine Your SLE with Novum™ Simplified Liquid ExtractionNovum SLE (patent pending) eliminates the questions associated with diatomaceous earth. As a lab manufactured sorbent, you can expect reliable, more consistent results.
And Now Introducing Novum PRO SLEThe same reliable SLE sorbent with our new manufacturing capabilities to help you
achieve low limits of detection with clean, high-throughput extractions.
Proudly manufactured at
PhenomenexHeadquarters in
Torrance, CA USA
3
Phenomenex l WEB: www.phenomenex.com4
Visit www.phenomenex.com/Novum for buffer and elution solvent recommendations, technical notes, demonstration videos, and more!
2. WAIT For 5 minutes.
Novum™ SLE follows a simple 3 step procedure, allowing up to 96 samples to be processed in < 15 minutes. If further time savings are necessary, Novum SLE can be easily automated for rapid, hands free sample cleanup.
A Simplified Procedure
1. LOAD Dilute sample 1:1 with buffer or water and load onto NovumSLE sorbent using 2–15 seconds of vacuum.
novumsim
plified liquid extraction
novumsim
plified liquid extraction
Optimized frit system provides a consistent
flow of sample into the Novum SLE sorbent
3. ELUTE Apply elution solvent and allow to elute via gravity. Complete elution with 10 seconds of vacuum.
novumsim
plified liquid extraction
novumsim
plified liquid extraction
Applying vacuum can reduce the amount
of time required for elution without
sacrificing cleanliness
See page 5 to learn moreabout the benefits of vacuum or
positive pressure manifold processing.
Novum Simplified Liquid Extraction (SLE)Estimated Time Required = <15 minutes
4
Phenomenex l WEB: www.phenomenex.com Phenomenex l WEB: www.phenomenex.com
0 %
10 %
20 %
30 %
40 %
50 %
60 %
70 %
80 %
90 %
100 %
Lyso 1 Lyso 2 PC 1 PC 2 PC 4
MTBE
DCM
Ethyl Acetate
A Cleaner Extract for Improved LC-MS/MS Analysis Phospholipids are present in all bioanalytical samples and can cause a variety of issues in LC-MS/MS analysis including ion suppression, reduced column lifetime, and reduced mass spec sensitivity.
Have you monitored the cleanup ability of your SLE product?
0 %
10 %
20 %
30 %
40 %
50 %
60 %
70 %
80 %
90 %
100 %
Lyso 1 Lyso 2 PC 1 PC 2 PC 4
MTBE
DCM
Ethyl Acetate
Phospholipids remain in the
extracted sample
Phospholipid Breakthrough Using Various Extraction Solvents
Biotage® ISOLUTE® SLE+* (diatomaceous earth)
Novum SLE (synthetic SLE sorbent)
Novum SLEresults in cleaner
extracts
Biotage® ISOLUTE® SLE+* vs. Novum™ SLE
Lyso 1: 1-Palmitoyl-2-OH-sn-glycero-phosphocholine (m/z 496-184)Lyso 2: 1-Oleoyl-2-OH-sn-glycero-phosphocholine (m/z 522-184)PC 1: 1-Palmitoyl-2-Oleoyl-sn-glycero-phosphocholine (m/z 761-184)PC 2: 1-Stearoyl-2-Lindoleoyl-sn-glycero-phosphocholine (m/z 787-184)PC 4: 1-Oleoyl-2-Lindoleoyl-sn-glycero-phosphocholine (m/z 784-184)
Extraction Method1. Load diluted plasma (diluted 1:1
with water) onto a SLE 96-Well Plate, apply vacuum for 2-5 seconds.2. Allow sample to soak into the SLE sorbent for 5 minutes.3. Elute with ethyl acetate.
Plasma extractions were performed using Novum SLE MAX and Biotage® ISOLUTE® SLE+* 400 µL plates. The recommended protocol provided with each product was followed. Comparative separations may not be representative of all applications.
5
Phenomenex l WEB: www.phenomenex.comPhenomenex l WEB: www.phenomenex.com6
0 %
10 %
20 %
30 %
40 %
50 %
60 %
70 %
80 %
90 %
100 %
Lyso 1 Lyso 2 PC 1 PC 2 PC 4
Novum SLE
Biotage® Isolute® SLE+*
Avoid the Risks Associated with Diatomaceous Earth SLEDiatomaceous earth sorbents can have inconsistent aqueous holding capacities, which ultimately results in sample breakthrough before or during the final vacuum or positive pressure step. This will yield unwanted phospholipids in sample extract as seen below.
Novum SLE will not allow water and phospholipids to breakthrough the sorbent during a standard vacuum or positive pressure step due to the consistent aqueous holding capacity, allowing you to maximize your extraction without negatively affecting your clean-up.
Even under a standard
vacuum elution, Novum still removes
>99% of phospholipids
Plasma extractions were performed using Novum SLE MAX and Biotage® ISOLUTE® SLE+* 400 µL plates. The recommended protocol provided with each product was followed. Comparative separations may not be representative of all applications.
Phospholipid Breakthrough Using 5” Hg VacuumNovum SLE vs. Biotage® ISOLUTE® SLE+*
Biotage® ISOLUTE® SLE+* vs. Novum™ SLE
Lyso 1: 1-Palmitoyl-2-OH-sn-glycero-phosphocholine (m/z 496-184)Lyso 2: 1-Oleoyl-2-OH-sn-glycero-phosphocholine (m/z 522-184)PC 1: 1-Palmitoyl-2-Oleoyl-sn-glycero-phosphocholine (m/z 761-184)PC 2: 1-Stearoyl-2-Lindoleoyl-sn-glycero-phosphocholine (m/z 787-184)PC 4: 1-Oleoyl-2-Lindoleoyl-sn-glycero-phosphocholine (m/z 784-184)
Extraction Method1. Load diluted plasma (diluted 1:1 with water)
onto a SLE 96-Well Plate, apply vacuum for 2-5 seconds.
2. Allow sample to soak into the SLE sorbent for 5 minutes.3. Elute with ethyl acetate.
Positive Pressure Manifold for Streamlined Sample Preparation • Pneumatic Handling • Consistent Flow Rates • Safe and Easy-to-Use • Go to www.phenomenex.com/Presston to learn more
Bitotage® ISOLUTE® SLE+*
Novum SLE
6
Phenomenex l WEB: www.phenomenex.com Phenomenex l WEB: www.phenomenex.comPhenomenex l WEB: www.phenomenex.com
More Reliable Clean-up,Lot-to-LotAs a naturally occurring product, the composition of diatomaceous earth used in traditional SLE products will vary. This results in inconsistency with the aqueous holding capacity which leads to incomplete cleanup of phospholipids.
Novum SLE is a lab manufactured sorbent, ensuring that the aqueous holding capacity is uniform leading to cleanup and recoveries that are consistent fromlot-to-lot.
Biotage® ISOLUTE® SLE+* vs. Novum™ SLE
Novum SLE Lot-to-Lot Phospholipid Breakthrough
Plasma extractions were performed using Novum SLE MINI and Biotage® ISOLUTE® SLE+* 200 µL plates. The recommended protocol provided with each product was followed. Comparative separations may not be representative of all applications.
0 %
10 %
20 %
30 %
40 %
50 %
60 %
70 %
80 %
90 %
100 %
Lyso 1 Lyso 2 PC 1 PC 2 PC 4
Biotage® Isolute® SLE+* lot #13165345SA
Biotage® Isolute® SLE+* lot #12161236TA
Biotage® ISOLUTE® SLE+* Lot-to-Lot Phospholipid Breakthrough
0.000 %
0.002 %
0.004 %
0.006 %
0.008 %
0.010 %
Lyso 1 Lyso 2 PC 1 PC 2 PC 4
Lot 1
Lot 2
Consistently remove > 99.9 % of phospholipids
Lyso 1: 1-Palmitoyl-2-OH-sn-glycero-phosphocholine (m/z 496-184)Lyso 2: 1-Oleoyl-2-OH-sn-glycero-phosphocholine (m/z 522-184)PC 1: 1-Palmitoyl-2-Oleoyl-sn-glycero-phosphocholine (m/z 761-184)PC 2: 1-Stearoyl-2-Lindoleoyl-sn-glycero-phosphocholine (m/z 787-184)PC 4: 1-Oleoyl-2-Lindoleoyl-sn-glycero-phosphocholine (m/z 784-184)
Extraction Method1. Load diluted plasma (diluted 1:1 with water) onto a SLE 96-Well Plate, apply vacuum for 2-5 seconds.2. Allow sample to soak into the SLE sorbent for 5 minutes.3. Elute with ethyl acetate.
Wow!
Bitotage® ISOLUTE® SLE+* lot #12161236TA
Bitotage® ISOLUTE® SLE+ lot #13165345SA
7
Phenomenex l WEB: www.phenomenex.com8
View more applications and informationabout Novum PRO SLE at
www.phenomenex.com/NovumPRO
Get Down to the Lowest Extraction Levels with Novum PRO SLE Offers the same reliable synthetic sorbent as Novum with additional clean manufacturing steps to reach low levels of detection for sensitive MS applications, with the same quality reproducibility for high-throughput samples.
• Specific manufacture capabilities to improve matrix factor response and reduce noisy baselines for low level testing of biological samples
• API 6500+ fit for purpose testing to ensure clean baseline with each batch• Available in both MINI and MAX 96-well plate formats for high-throughput
applications
Simple Method with Easy Transferability• Load• Wait• Elute
Low Level Detection• Applications that require low levels of
detection and sensitivity can now be met by Novum PRO SLE
Equivalent reliability to traditional synthetic Novum SLE
Detection Limits Getting Smaller and Smaller?
2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0 min0.0
500.0
1000.0
1500.0
2000.0
2500.0
3000.0
3500.0
4000.0
4500.0
5000.0
5500.0
6000.0
6500.0
7000.0
7500.0
8000.0
8500.0
9000.0
9500.0
1.0e4
1.1e4
1.1e4
1.2e4
1.2e4
1.3e4
1.3e4
1.4e4
1.4e4
Intensity, cps
3.93
3.08
3.40
3.20
2.93
2.522.36
2.63
5 pg/mL (LLOQ) Estriol (E3)
App
ID 2
6234
Easy Method Development• Screen elution solvents in less time• Easily determine the best solvent to use
for clean backgrounds
8
Phenomenex l WEB: www.phenomenex.com Phenomenex l WEB: www.phenomenex.com
Estrogen Panel from Plasma
Novum PRO SLE Protocol Pretreatment: 200 μL spiked plasma and 200 μL 50 mM Sodium phosphate buffer, pH unadjustedLoad: Pretreated sample onto Novum PRO MAX SLE (8E-S539-5GA), wait 5 minutes Elute: 2x 900 μL Hexane/Ethyl acetate (1:3)Dry: Down under NitrogenReconstitute: 50 μL Dansyl chloride/Sodium bicarbonate (1:1), incubate at 60 °C for 10 minutes
Low Level Hormones from Plasma Sensitive analysis requirements require clean MS backgrounds and precise low levels of analyte extractions. Novum PRO SLE makes this possible with LLOQs of 5-10 pg/mL for multiple estrogens and testosterone from plasma. With some diatomaceous earth SLE sorbents, background interferences can make peaks undetectable but with Novum PRO, recoveries are high with low limits of detection on a sensitive MS.
Reach highrecoveriesat LLOQ
Conditions for all samples:Columns: Kinetex® 1.7 μm Biphenyl
Dimensions: 50 x 2.1 mmPart No.: 00B-4628-AN
Mobile Phase: A: 0.1% Formic acid in Water B: 0.1% Formic acid in Methanol
Gradient: Time (min)012366.18
% B80809095958080
Flow Rate: 0.4 mL/minTemperature: Ambient
Injection: 10 µLDetection:
Analyte %Recovery %CV LLOQ Retention Time
Estrone (E1) 111 7 10 pg/mL 5.90
beta-Estadiol (E2) 92 7 10 pg/mL 4.35
Estriol (E3) 99 1 5 pg/mL 3.15
Estrogen Panel Recovery on Novum PRO SLE
Representative Chromatogram of Estrogen Panel at 2 ng/mL
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 min0.0
2.0e6
4.0e6
6.0e6
8.0e6
1.0e7
1.2e7
1.4e7
1.6e7
1.8e7
2.0e7
2.2e7
2.4e7
2.6e7
2.8e7
3.0e7
3.2e7
3.4e7
3.6e7
3.8e7
4.0e7
4.2e7
4.4e7
sp
c ,
yti
sn
etnI
App
ID 2
6214
New Novum PRO. Move Over Biotage® ISOLUTE® SLE+
9
Phenomenex l WEB: www.phenomenex.com10
0.5
1
1.5
2
3
3.5
4
4.5
5
0 20 40 60 80 100
2.5
5.2
120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500
beta-E2 Calibration Curve 10 pg/mL (LLOQ) beta-Estradiol
R2=.9955
3.4 3.6 3.8 4.0 4.2 4.4 4.6 4.8 5.0 min0
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800
4000
4200
4400
4600
4800
5000
5200
5400
5600
5800
6000
6200
6400
6600
6800
7000
7200
7400
7600
7800
8000
8200
8400
8600
8800
9000
Inte
nsity
, cps
4.28
4.08
3.92
3.47
4.65
4.73
5.15
App
ID 2
6233
App
ID 2
6230
App
ID 2
6234
2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0 min0.0
500.0
1000.0
1500.0
2000.0
2500.0
3000.0
3500.0
4000.0
4500.0
5000.0
5500.0
6000.0
6500.0
7000.0
7500.0
8000.0
8500.0
9000.0
9500.0
1.0e4
1.1e4
1.1e4
1.2e4
1.2e4
1.3e4
1.3e4
1.4e4
1.4e4
Intensity, cps
3.93
3.08
3.40
3.20
2.93
2.522.36
2.63
5 pg/mL (LLOQ) Estriol (E3) Calibration Curve of E3 from 2.5 to 500 pg/mL
0.2
0.6
1
0 20 40 60 80 100
1.2
120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 5000
0.4
0.8
1.4
1.6
1.8
2
2.2
2.4
App
ID 2
6231
R2=.9966
Move over Biotage! New Novum
PRO is here!
4.8 5.0 5.2 5.4 5.6 5.8 6.0 6.2 6.4 min0
200
400
600800
10001200
1400
16001800
20002200
2400
26002800
30003200
3400
36003800
40004200
4400
46004800
50005200
5400
56005800
60004.82
5.69
5.425.35
App
ID 2
6232
10 pg/mL (LLOQ) Estrone (E1) Calibration Curve of E1 from 5 to 500 pg/mL
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500Analyte Conc. / IS Conc.
0.000.050.100.150.200.250.300.350.400.450.500.550.600.650.700.750.800.850.900.951.001.05
aerA
SI / aerA etylan
A
App
ID 2
6215
R2=.9963
Estrogen Panel from Plasma (cont’d)
Ana
lyte
Are
a /
IS A
rea
Analyte Conc. / IS Conc.
10
Ana
lyte
Are
a /
IS A
rea
Analyte Conc. / IS Conc.
Inte
nsit
y, C
PS
Inte
nsit
y, C
PS
Inte
nsit
y, C
PS
Phenomenex l WEB: www.phenomenex.com Phenomenex l WEB: www.phenomenex.com
80 pg/mL Testosterone
1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 min0
100020003000400050006000700080009000
1e41.1e41.2e41.3e41.4e41.5e41.6e41.7e41.8e41.9e4
2e42.1e42.2e42.3e4
Inte
nsity
, cps
App
ID 2
6240
Reach required LLOQ with Novum PRO SLEwith no background interferences.
App
ID 2
6236
1000
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 380
2000
3000
4000
5000
6000
7000
8000
9000
Plasma Blank
20 pg/mL of Testosterone
1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 min
1000
0
2000
3000
4000
5000
6000
7000
8000
9000
1e4
1.10e4
Inte
nsity
, cps
Testosterone Panel from Plasma Novum PRO SLE Protocol Pretreatment: 200 μL spiked plasma and 200 μL 50 mM Sodium phosphate buffer, pH unadjustedLoad: Pretreated sample onto Novum PRO MAX SLE (8E-S539-5GA), wait 5 minutes Elute: 2x 900 μL Hexane/Ethyl acetate (1:3)Dry: Down under NitrogenReconstitute: 50 μL Water/Methanol (80:20)
Conc. S/N
10 pg/mL 9.42
25 pg/mL 25.93
50 pg/mL 33.17100 pg/mL 77.59250 pg/mL 202.07500 pg/mL 138.62
Signal-to-Noise Ratio at Diverse Concentrations
10 pg/mL (LLOQ) of Testosterone
1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 min0200
1000
2000
3000
4000
5000
6000
7000
8000
9000
Inte
nsity
, cps
Conditions for all samples:Columns: Kinetex® 1.7 μm Biphenyl
Dimensions: 50 x 2.1 mmPart No.: 00B-4628-AN
Mobile Phase: A: 0.1% Formic acid in Water B: 0.1% Formic acid in Methanol
Gradient: Time (min)0233.15
% B6090956060
Flow Rate: 0.4 mL/minTemperature: Ambient
Injection: 10 µLDetection: SCIEX® 6500+ QTRAP® MS/MS
Sample: Testerstone
Inte
nsit
y, C
PS
Inte
nsit
y, C
PS
Inte
nsit
y, C
PS
Inte
nsit
y, C
PS
Good signal-to-noisefor different
concentrations oftestosterone!
1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 min0200
1000
2000
3000
4000
5000
6000
7000
8000
9000
Inte
nsity
, cps
App
ID 2
6238
App
ID 2
6239
11
Phenomenex l WEB: www.phenomenex.comPhenomenex l WEB: www.phenomenex.com12
Calibration Curve of Testosterone from 10 to 300 pg/mL
10 50 100 150 200 250Analyte Conc. / IS Conc.
0
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.750.79
Ana
lyte
Are
a / I
S A
rea
App
ID 2
6235
Testerstone Recovery and at Diverse Concentrations
Testosterone % Recovery % CV
20 pg/mL 111 10
40 pg/mL 92 9
80 pg/mL 99 12150 pg/mL 105 12300 pg/mL 103 12
Recovery Data
R2=.995
Good recoveries and low %CVs at diverse levels of
concentration with clean-upusing Novum PRO!
Quotes, Methods, Tips... We're here to help
www.phenomenex.com/ChatNow
Have Questions?
Testosterone Panel from Plasma (cont’d)
12
Ana
lyte
Are
a /
IS A
rea
Analyte Conc. / IS Conc.
Phenomenex l WEB: www.phenomenex.com Phenomenex l WEB: www.phenomenex.comPhenomenex l WEB: www.phenomenex.com
Faster Method DevelopmentSLE products may be the single easiest method development product, making it super easy to screen for diverse extraction solvents. With Novum™ SLE, you can trust that results will be consistent with the correct extraction solvent.
For typical applications, Novum™ SLE provides excellent recovery and cleanup using ethyl acetate as an extraction solvent, significantly reducing your method development time.
Recovery of 18 Pain Management Drugs from Urine
using a Single Extraction Method on Novum SLE
0 %
20 %
40 %
60 %
80 %
100 %
120 %
Amphe
tam
ine
Bupre
norp
hine
Codein
e
Fent
anyl
MDM
A
MDEA
Mep
eridine
Met
hadon
e
Mep
robam
ate
Met
ham
pheta
mine
Norfe
ntan
yl
Norm
eper
idinePCP
Propox
yphe
ne
Sufen
tanil
Tem
azep
am
Tram
adol
Nordiaz
epam
Rec
over
y (%
)
Analyte % RSD
Amphetamine 3
Buprenorphine 5
Codeine 10
Fentanyl 6
MDEA 4
MDMA 4
Meperidine 9
Meprobamate 7
Methadone 2
Methamphetamine 12
Nordiazepam 1
Norfentanyl 3
Normeperidine 4
PCP 2
Propoxyphene 9
Sufentanil 11
Temazepam 2
Tramadol 9
A Simplified Procedure
For typical applications ethyl acetate provides the
best balance of cleanup and recovery! But screening for multiple solvents is easy
with Novum SLE.Extraction Method1. Load diluted urine (diluted 1:1 with 0.5 M Ammonium hydroxide) onto Novum SLE MAX 96-well plate, apply vacuum for 2-15 seconds
2. Allow sample to soak into Novum SLE sorbent for 5 minutes
3. Elute with ethyl acetate
13
Phenomenex l WEB: www.phenomenex.com14
A Variety of Formats to Fit Your Sample and Throughput RequirementsTubesProcess samples as small as 100 µL or as large as 1 mL using Novum SLE tubes. Ideal for all types of applications including Bioanalytical, Food Safety, and Environmental.
96-Well PlatesProcess 96 samples at once in an easily automatable 96-well plate. Perfect for high-throughput applications
novumsim
plified liquid extraction
novumsim
plified liquid extraction
novumsim
plified liquid extraction
novumsim
plified liquid extraction
novumsim
plified liquid extraction
novumsim
plified liquid extraction
novumsim
plified liquid extraction
novumsim
plified liquid extraction
Novum SLE Tube 1 cc 3 cc 6 cc 12 cc
Maximum Sample Volume (before dilution)
100 µL 200 µL 500 µL 1 mL
Recommended Elution Volume 1.2 mL 1.8 mL 5 mL 10 mL
Novum SLE 96-Well Plate MINI MAX
Maximum Sample Volume (before dilution)
150 µL 200 µL
Recommended Elution Volume 1 mL 1.8 mL
New Novum PRO 96-Well Plates Made to reach low level extraction capabilities with new manufacturing
processes and same 96-well plate formats as traditional Novum forhigh-throughput, reliable SLE clean-up.
14
Phenomenex l WEB: www.phenomenex.com Phenomenex l WEB: www.phenomenex.com
AccessoriesCollection Plates (deep well, polypropylene) UnitAH0-7192 96-Well Collection Plate, 350 µL/well Conical 50/pkAH0-7193 96-Well Collection Plate, 1 mL/well Conical 50/pkAH1-7022 96-Well Collection Plate, 2 mL/well Conical 50/pkAH0-8636 96-Well Collection Plate, 2 mL Round/Round, 8 mm 50/pkAH1-7025 96-Well Collection Plate, 1 mL/well Round, 7 mm 50/pkSealing MatsAH0-8597 Sealing Mats, Pierceable, 96-Square Well, Silicone 50/pkAH0-8598 Sealing Mats, Pre-Slit, 96-Square Well, Silicone 50/pkAH0-7362 Sealing Tape Pad 10/pkVacuum and Positive Pressure ManifoldsAH0-8950 96-Well Plate Manifold, Universal with Vacuum Gauge eaVM12 12-Position Vacuum Manifold Set eaVM24 24-Position Vacuum Manifold Set eaAH1-7033 Presston 1000 Postive Pressure Manifold, 96-Well Plate ea
Terms and Conditions Subject to Phenomenex Standard Terms and Conditions, which may be viewed at www.phenomenex.com/TermsAndConditions. Trademarks Novum, BE-HAPPY, and Presston are trademarks and Kinetex is a registered trademark of Phenomenex. Biotage and ISOLUTE are registered trademarks of Biotage AB.
Disclaimer Comparative separations may not be representative of all applications. Novum is patent pending. Phenomenex is in no way affiliated with Biotage AB.
FOR RESEARCH USE ONLY. Not for use in clinical diagnostic procedures.
© 2021 Phenomenex, Inc. All rights reserved.
TipFor more information about Phenomenex sample preparation products, visit www.phenomenex.com/sampleprepinfo
Redefine Your SLE Novum SLE 96-Well Plates
Part No. Description Unit8E-S138-FGA Novum SLE MINI 96-Well Plate 1/pk8E-S138-5GA Novum SLE MAX 96-Well Plate 1/pk8E-S539-FGA Novum PRO SLE MINI, 96-Well Plate 1/pk8E-S539-5GA Novum PRO SLE MAX, 96-Well Plate 1/pk
Novum SLE Tubes
Part No. Description Unit8B-S138-FAK Novum SLE 1 cc tubes 100/pk8B-S138-5BJ Novum SLE 3 cc tubes 50/pk8B-S138-JCH Novum SLE 6 cc tubes 30/pk8B-S138-KDG Novum SLE 12 cc tubes 20/pk
Phenomenex warrants the Presston 1000 Positive Pressure Manifold against defects in materials and workmanship under normal installation, use, and maintenance for a period of 12 months following delivery. Please visit www.phenomenex.com/presstonwarranty for complete warranty information.
Your happiness is our mission. Take45 days to try our products.
If you
are not happy, we’ll make it right.
guarantee
www.phenomenex.com/behappy
Take
novumsimplified liquid extraction
novumsimplified liquid extraction
novumsimplified liquid extraction
novumsimplified liquid extraction
15
Faster. Easier. Reliable.
SLE Simplified.
novumsimplified liquid extraction
BR
2898
1120
_W
Australiat: +61 (0)2-9428-6444
Austriat: +43 (0)1-319-1301
Belgiumt: +32 (0)2 503 4015 (French)t: +32 (0)2 511 8666 (Dutch)
Canadat: +1 (800) 543-3681
Chinat: +86 400-606-8099
Czech Republict: +420 272 017 077
Denmarkt: +45 4824 8048
Finlandt: +358 (0)9 4789 0063
Francet: +33 (0)1 30 09 21 10
Germanyt: +49 (0)6021-58830-0
Indiat: +91 (0)40-3012 2400
Irelandt: +353 (0)1 247 5405
Italyt: +39 051 6327511
Luxembourgt: +31 (0)30-2418700
Mexicot: 01-800-844-5226
The Netherlandst: +31 (0)30-2418700
New Zealandt: +64 (0)9-4780951
Norwayt: +47 810 02 005
Polandt: +48 22 104 21 72
Portugalt: +351 221 450 488
Singaporet: +65 800-852-3944
Slovakiat: +420 272 017 077
Spaint: +34 91-413-8613
Swedent: +46 (0)8 611 6950
Switzerlandt: +41 (0)61 692 20 20
Taiwant: +886 (0) 0801-49-1246
Thailandt: +66 (0) 2 566 0287
United Kingdomt: +44 (0)1625-501367
USAt: +1 (310) 212-0555
All other countries/regions Corporate Office USA
t: +1 (310) 212-0555 [email protected]
www.phenomenex.comPhenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at [email protected]
PATENT PENDING