simultaneous in-situ analysis of instabilities and first ... · physical hydrogels with good...

3
ABSTRACT The paper researched 10 wt% Pluronic F68 and 15 wt% Pluronic F127 with 5 wt% chondroitin-4-sulfate(CS) in Phosphate- buffered saline(PBS) in order to design physical hydrogels with good stability at 37°C. Pluronic hydrogels with 5 wt% CS are thermoreversible, and it is very fast to answer the thermal stimulus by rheology. INTRODUCTION Injectable hydrogels are environment responsive sol-gel transition behavior in solution, therefore, we pay more attention for versatile applications for macromolecular drug delivery and tissue engineering. Among the injectable hydrogel, PEO-PPO-PEO triblock copolymers also known as the Pluronics, is widely used as injectable carriers. However, Pluronic hydrogel injected into the body, the formed in situ Pluronic hydrogel structure was quickly disintergrated at the local site due to rapid dilution with the body fluid. Pluronic hydrogel formed physically crosslinked hydrogels in human body, the limit of its use due to the unstable. So, researchers have been many efforts to modify or blend the PEO-PPO-PEO copolymer structure in order to enhance their stability. 1,2 Chondroitin-4- sulfate based hydrogels will be a versatile platform for a wide range of application in drug delivery when an injection is required. 3 The structure of chondroitin sulfate is shown in Figure 1, according permeability coefficient to Table 1. 4 Table 1. The name and permeability coefficient of chondroitin sulfate. Letter identification Systematic name Permeability coefficient (x 10 -6 ) (n=3) (cm/sec) Chondroitin sulfate A chondroitin- 4-sulfate 10.1 (± 0.6) Chondroitin sulfate C chondroitin- 6-sulfate 7.94 (± 7.35) Chondroitin sulfate D chondroitin- 2,6-sulfate 0.00 (± 0.00) Chondroitin sulfate E chondroitin- 4,6-sulfate 3.63 (± 2.07) Figure 2. The structure of one unit in a chondroitin sulfate chain. MATERIALS Pluronic F127 and Pluronic F68 were purchased from Sigma -Aldrich. Chondroitin-4- sulfate (CS) were purchased The sol-gel of chondroitin-4-sulfate -based Pluronic hydrogels as injectable biomaterials Di Sun and Walther Richtering Institute of Physical Chemistry, RWTH Aachen, Aachen, Germany ANNUAL TRANSACTIONS OF THE NORDIC RHEOLOGY SOCIETY, VOL. 24, 2016 217

Upload: vodan

Post on 02-May-2018

215 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Simultaneous In-situ Analysis of Instabilities and First ... · physical hydrogels with good stability at 37°C ... responsive sol-gel transition behavior in ... reversible thermos-reversible

ABSTRACT The paper researched 10 wt% Pluronic

F68 and 15 wt% Pluronic F127 with 5 wt% chondroitin-4-sulfate(CS) in Phosphate-buffered saline(PBS) in order to design physical hydrogels with good stability at 37°C. Pluronic hydrogels with 5 wt% CS are thermoreversible, and it is very fast to answer the thermal stimulus by rheology.

INTRODUCTION

Injectable hydrogels are environment responsive sol-gel transition behavior in solution, therefore, we pay more attention for versatile applications for macromolecular drug delivery and tissue engineering. Among the injectable hydrogel, PEO-PPO-PEO triblock copolymers also known as the Pluronics, is widely used as injectable carriers. However, Pluronic hydrogel injected into the body, the formed in situ Pluronic hydrogel structure was quickly disintergrated at the local site due to rapid dilution with the body fluid. Pluronic hydrogel formed physically crosslinked hydrogels in human body, the limit of its use due to the unstable. So, researchers have been many efforts to modify or blend the PEO-PPO-PEO copolymer structure in order to enhance their stability.1,2 Chondroitin-4-sulfate based hydrogels will be a versatile platform for a wide range of application in drug delivery when an injection is required.3 The structure of chondroitin sulfate is shown

in Figure 1, according permeability coefficient to Table 1.4 Table 1. The name and permeability coefficient of chondroitin sulfate. Letter identification

Systematic name

Permeability coefficient (x 10-6) (n=3) (cm/sec)

Chondroitin sulfate A

chondroitin-4-sulfate

10.1 (± 0.6)

Chondroitin sulfate C

chondroitin-6-sulfate

7.94 (± 7.35)

Chondroitin sulfate D

chondroitin-2,6-sulfate

0.00 (± 0.00)

Chondroitin sulfate E

chondroitin-4,6-sulfate

3.63 (± 2.07)

Figure 2. The structure of one unit in a chondroitin sulfate chain. MATERIALS Pluronic F127 and Pluronic F68 were purchased from Sigma -Aldrich. Chondroitin-4- sulfate (CS) were purchased

The sol-gel of chondroitin-4-sulfate -based Pluronic hydrogels as injectable

biomaterials

Di Sun and Walther Richtering

Institute of Physical Chemistry, RWTH Aachen, Aachen, Germany

Simultaneous In-situ Analysis of Instabilities and First Normal StressDifference during Polymer Melt Extrusion Flows

Roland Kádár1,2, Ingo F. C. Naue2 and Manfred Wilhelm2

1 Chalmers University of Technology, 41258 Gothenburg, Sweden2 Karlsruhe Institute of Technology - KIT, 76128 Karlsruhe, Germany

ANNUAL TRANSACTIONS OF THE NORDIC RHEOLOGY SOCIETY, VOL. 24, 2016

ABSTRACTA high sensitivity system for capillaryrheometry capable of simultaneously de-tecting the onset and propagation of insta-bilities and the first normal stress differ-ence during polymer melt extrusion flowsis here presented. The main goals of thestudy are to analyse the nonlinear dynam-ics of extrusion instabilities and to deter-mine the first normal stress difference inthe presence of an induced streamline cur-vature via the so-called ’hole effect’. Anoverview of the system, general analysisprinciples, preliminary results and overallframework are herein discussed.

INTRODUCTIONCapillary rheometry is the preferredrheological characterisation method forpressure-driven processing applications,e.g. extrusion, injection moulding. Themain reason is that capillary rheometry isthe only method of probing material rheo-logical properties in processing-like condi-tions, i.e. high shear rate, nonlinear vis-coelastic regime, albeit in a controlledenvironment and using a comparativelysmall amount of material.1 Thus, it isof paramount importance to develop newtechniques to enhance capillary rheome-ters for a more comprehensive probing ofmaterial properties. Extrusion alone ac-counts for the processing of approximately35% of the worldwide production of plas-tics, currently 280⇥ 106 tons (Plastics Eu-rope, 2014). This makes it the most im-portant single polymer processing opera-

tion for the industry and can be found ina variety of forms in many manufacturingoperations. Extrusion throughput is lim-ited by the onset of instabilities, i.e. prod-uct defects. Comprehensive reviews on thesubject of polymer melt extrusion insta-bilities can be found elsewhere.4,6 A re-cent method proposed for the detectionand analysis of these instabilities is that ofa high sensitivity in-situ mechanical pres-sure instability detection system for cap-illary rheometry.8,10 The system consistsof high sensitivity piezoelectric transducersplaced along the extrusion slit die. In thisway all instability types detectable, thusopening new means of scientific inquiry. Asa result, new insights into the nonlinear dy-namics of the flow have been provided.9,14

Moreover, the possibility of investigatingthe reconstructed nonlinear dynamics wasconsidered, whereby a reconstructed phasespace is an embedding of the original phasespace.2,14 It was shown that a positive Lya-punov exponent was detected for the pri-mary and secondary instabilities in lin-ear and linear low density polyethylenes,LDPE and LLDPE,.14 Furthermore, it wasdetermined that Lyapunov exponents aresensitive to the changes in flow regime andbehave qualitatively different for the iden-tified transition sequences.14 It was alsoshown that it is possible to transfer thehigh sensitivity instability detection sys-tem to lab-sized extruders for inline ad-vanced processing control and quality con-trol systems.13

A very recent possibility considered

217

Page 2: Simultaneous In-situ Analysis of Instabilities and First ... · physical hydrogels with good stability at 37°C ... responsive sol-gel transition behavior in ... reversible thermos-reversible

from Alfa Aesar and Phosphate-buffered saline(PBS) from Amesco, respectively. All chemicals were used without further purification. All solutions and gels were prepared with doubly distilled water. METHODS

The formulations were prepared by dissolving different amounts of Pluronic F127 and Pluronic F68 with 5 wt% Chondroitin-4-sulfate solution by mixing under continuous stirring at 4 °C until a clear solution. The clear solution form the gel under room temperature.

RHEOLOGY

The rheology experiments include temperature sweep and viscometry which were carried out with a Kinexus pro (Malvern) rheometer. For all measurements parallel plate tools (40 mm diameter) were used and all samples were measured directly after polymerization without further swelling. The temperature sweep measurements were performed at heating rate of 1°C/min. The shear stress was varied between 0.01 and 100 Pa.

10 20 30 40 50 600,01

0,1

1

10

100

1000

10000

100000

G',G

''/ P

a

Temperature/°C

G'-heating G''-heating G'-cooling G''-cooling

Figure 2.Temperature ramp of 10 wt% Pluronic F68 and 15 wt% Pluronic F127 and 10 wt% F68 with the addition of 5 wt% chondroitin-4-sulfate. The temperature sweep measurements were performed at heating and cooling rate of 1°C/min.

We blend of CS and Pluronic hydrogel in PBS solutions and successfully obtained

the physical hydrogel which is close to the body temperature. The rheological measurements of Pluronic hydrogel blended with chondroition-4-sulfate showed that the gelation temperature of the Pluronic is closed to body temperature by the addition of 5 wt%. As showed in Figure 2, the viscoelastic moduli showed a sharp increase near the gel point, G’ increases more than 4 orders of magnitude and reaches a constant level (12 000 Pa), which were very sensitive to the sol−gel transition process was obtained. Kyung et al.5 found The CP solution underwent a sol–gel transition around 25 °C at which the storage modulus (G′) approaches 104 Pa, highlighting the potential of this material as an injectable scaffold for cartilage regeneration.

0 10 20 30 40 50 60

0,1

1

10

100

1000

10000

G',G

''/ P

a

T/°C

G' PBS-5 wt% CS G''

Figure 3.Temperature ramp of 5 wt% chondroitin-4-sulfate in PBS. The temperature sweep measurements were performed at heating rate of 1°C/min. Figure 3 described CS that undergo a temperature induced phase transition in Pluronic solution providing an important basis for enhancing their stability. The G’ is higher than G’’ when CS concentration increased to 5 wt% in PBS. It means CS formed the weak gel in PBS.

D. Sun and W. Richtering

218

Page 3: Simultaneous In-situ Analysis of Instabilities and First ... · physical hydrogels with good stability at 37°C ... responsive sol-gel transition behavior in ... reversible thermos-reversible

0,01 0,1 1 10 100

0,01

0,1

1

10

100

1000

10000

100000

1000000

S

hear

vis

cosi

ty/P

a s

Shear rate/ s-1

20 °C 37°C 50°C

Figure 4. Shear rate dependence of the viscosity of 10 wt% Pluronic F68 -15 wt% F127 Pluronic with 5 wt % CS in PBS.

We examined the effect of chondroitin

sulfate on the viscosity of different solutions through their rheological flow behavior. The viscosity of the solution containing 5 wt% chondroitin -4-sulfate in a flow was constant at all shear rates examined (0,01–100 s−1) at room temperature.

However, the viscosity of solutions of hydrogel plus chondroitin sulfate decreased in a shear rate-dependent manner, exhibiting shear thinning behavior. CONCLUSION

The rheological properties of the gels were intended for the local administration of drugs by injection. We studied the effect of Pluronic hydrogel with branched polysaacharides on the rheological properties. Indeed, the heteroglycans’s polysaacharides strengthened the network due to their interactions with multiblock copolymers of PEO-PPO-PEO in PBS by sol-gel gelation, resulting the Pluronic hydrogel with 5 wt% CS was totally the reversible thermos-reversible properties. It was easy to injectable through needles due to the shear thinning behavior of the gels. ACKNOWLEDGMENTS

We thank to the China Scholarship Council for funding (201306740056).

REFERENCES 1. Hoffman, A. S. (2012), Hydrogels for biomedical applications. Advanced drug delivery reviews, 64, 18-23. 2. Ruel-Gariepy, E.; Leroux, J.-C.(2004), In situ-forming hydrogels—review of temperature-sensitive systems. European Journal of Pharmaceutics and Biopharmaceutics, 58, 409-426. 3. Millane, R.; Mitra, A.; Arnott, S.(1983) Chondroitin 4-sulfate: Comparison of the structures of the potassium and sodium salts. Journal of molecular biology, 169, 903-920. 4. Uebelhart, D. (2008), Clinical review of chondroitin sulfate in osteoarthritis., Osteoarthritis and Cartilage, 16, 19-21. 5. Park, K. M.; Lee, S. Y.; Joung, Y. K.; Na, J. S.; Lee, M. C.; Park, K. D. (2009),Thermosensitive chitosan–Pluronic hydrogel as an injectable cell delivery carrier for cartilage regeneration. Acta biomaterialia, 5, 1956-1965.

Simultaneous In-situ Analysis of Instabilities and First Normal StressDifference during Polymer Melt Extrusion Flows

Roland Kádár1,2, Ingo F. C. Naue2 and Manfred Wilhelm2

1 Chalmers University of Technology, 41258 Gothenburg, Sweden2 Karlsruhe Institute of Technology - KIT, 76128 Karlsruhe, Germany

ANNUAL TRANSACTIONS OF THE NORDIC RHEOLOGY SOCIETY, VOL. 24, 2016

ABSTRACTA high sensitivity system for capillaryrheometry capable of simultaneously de-tecting the onset and propagation of insta-bilities and the first normal stress differ-ence during polymer melt extrusion flowsis here presented. The main goals of thestudy are to analyse the nonlinear dynam-ics of extrusion instabilities and to deter-mine the first normal stress difference inthe presence of an induced streamline cur-vature via the so-called ’hole effect’. Anoverview of the system, general analysisprinciples, preliminary results and overallframework are herein discussed.

INTRODUCTIONCapillary rheometry is the preferredrheological characterisation method forpressure-driven processing applications,e.g. extrusion, injection moulding. Themain reason is that capillary rheometry isthe only method of probing material rheo-logical properties in processing-like condi-tions, i.e. high shear rate, nonlinear vis-coelastic regime, albeit in a controlledenvironment and using a comparativelysmall amount of material.1 Thus, it isof paramount importance to develop newtechniques to enhance capillary rheome-ters for a more comprehensive probing ofmaterial properties. Extrusion alone ac-counts for the processing of approximately35% of the worldwide production of plas-tics, currently 280⇥ 106 tons (Plastics Eu-rope, 2014). This makes it the most im-portant single polymer processing opera-

tion for the industry and can be found ina variety of forms in many manufacturingoperations. Extrusion throughput is lim-ited by the onset of instabilities, i.e. prod-uct defects. Comprehensive reviews on thesubject of polymer melt extrusion insta-bilities can be found elsewhere.4,6 A re-cent method proposed for the detectionand analysis of these instabilities is that ofa high sensitivity in-situ mechanical pres-sure instability detection system for cap-illary rheometry.8,10 The system consistsof high sensitivity piezoelectric transducersplaced along the extrusion slit die. In thisway all instability types detectable, thusopening new means of scientific inquiry. Asa result, new insights into the nonlinear dy-namics of the flow have been provided.9,14

Moreover, the possibility of investigatingthe reconstructed nonlinear dynamics wasconsidered, whereby a reconstructed phasespace is an embedding of the original phasespace.2,14 It was shown that a positive Lya-punov exponent was detected for the pri-mary and secondary instabilities in lin-ear and linear low density polyethylenes,LDPE and LLDPE,.14 Furthermore, it wasdetermined that Lyapunov exponents aresensitive to the changes in flow regime andbehave qualitatively different for the iden-tified transition sequences.14 It was alsoshown that it is possible to transfer thehigh sensitivity instability detection sys-tem to lab-sized extruders for inline ad-vanced processing control and quality con-trol systems.13

A very recent possibility considered

219