sin título-2 - pacific blowers...*the allowable tolerance of dimension is ± 5mm *the dimension can...

3
* The allowable tolerance of dimension is ± 5mm *The dimension can be changed for improvement without notice. RING BLOWER VACUUM & PRESSURE PB-301 www.pacificblowers.com - Call Us: (305) 718-8895 - Fax: (305) 722-7387 - info@pacificblowers.com Third Angle Single Phase 343mm (13,5") 338mm (13,3") 85mm (3,34") 155mm (6,1") 325mm (12,8") 115mm (4,52") 29 HOLE 299mm (11,77") 53mm (2,08") 120mm (4,72") 177mm (6,96") 325mm (12,8") 262mm (10,31") (INLET PORT) (DISCHARGE PORT) PT 2" PT 2" 4 - 15 HOLE

Upload: others

Post on 30-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • * The allowable tolerance of dimension is ± 5mm

    *The dimension can be changed for improvement without notice.

    RING BLOWER VACUUM & PRESSURE

    PB-301

    www.pacificblowers.com - Call Us: (305) 718-8895 - Fax: (305) 722-7387 - [email protected]

    Third Angle

    Single Phase

    343mm(13,5")

    338m

    m(1

    3,3

    ")

    85mm(3,34") 155mm

    (6,1")

    325mm(12,8")

    115mm(4,52")

    29 HOLE

    299mm(11,77")

    53

    mm

    (2,0

    8")

    120mm(4,72")

    177m

    m(6

    ,96

    ")

    325mm(12,8")

    262mm(10,31")

    (INLET PORT)

    (DISCHARGE PORT)

    PT 2"

    PT 2"

    4 - 15 HOLE

  • 60Hz50Hz

    ADVANTAGES

    * Low noise 75dB

    * Continuous, low-maintenance operation

    * Saves space and electricity

    * Trouble-free installation

    * Easy replacement of parts

    * Outboard bearings yielding longer life

    * Dual voltage 110/230

    PRODUCT OPTIONS

    * 2” Relief Valve (recommended)

    * Inlet Filter (recommended)

    * Check Valve (recommended)

    * Silencer (recommended)

    * Liquid filled gauge (recommended)

    * Enclosed motor starter (recommended)

    * Filter motor gauge (recommended)

    * Belt-driven bare shaft blowers are

    available upon request (Special Order)

    * Explosion proof motors available upon

    request (Special Order)

    [Class 2/Groups E,F,G/Division 1 Certified]

    * The performances above were measured under conditions of air temperature 20ºC and

    atmospheric pressure 1,013 mbar

    * The allowable tolerance of the perfomance value is ± 10%

    * The sound level was measured at a distance of 1.5m with the fully open inlet and outlet ports

    * The continuous operation can be made at a point below the curve, however, the continuous

    operation nearby the rated pressure point may cause a motor breakdown. In the case of

    continuous operation close to the rated pressure, it is strongly recommended to use the

    pressurerelief valve.

    * The allowable tolerance of the performance value is ± 10%

    PERFORMANCE CURVES

    50Hz 60Hz

    PhaseMotor

    (HP)

    Motor

    (Kw)

    Current (A) 110 / 220 V

    Flow

    (cfm)

    Flow

    (m3/min)

    Flow

    (m3/hr)

    Max

    Pressure

    (in H2O)

    Max

    Pressure

    (mmAq)

    Max

    Pressure

    (psig)

    Max

    Pressure

    (mbar)

    Max

    Vacuum

    (in H2O)

    Max

    Vacuum

    (mmAq)

    Max

    Vacuum

    (psig)

    Max

    Vacuum

    (mbar)

    Sound

    Level

    (dB/A)

    Weight

    (lbs.)

    Weight

    (Kg)

    Diameter

    (INLET/OUTLET)

    inch

    1 2,0 1,50 25.0/ 12.5 141 4,0 240 71 1800 2,56 177 63 1600 2,27 157 75 73 33 2

    PhaseMotor

    (HP)

    Motor

    (Kw)

    Current (A)

    110 / 220 V

    Flow

    (cfm)

    Flow

    (m3/min)

    Flow

    (m3/hr)

    Max

    Pressure

    (in H2O)

    Max

    Pressure

    (mmAq)

    Max

    Pressure

    (psig)

    Max

    Pressure

    (mbar)

    Max

    Vacuum

    (in H2O)

    Max

    Vacuum

    (mmAq)

    Max

    Vacuum

    (psig)

    Max

    Vacuum

    (mbar)

    Sound

    Level

    (dB/A)

    Weight

    (lbs.)

    Weight

    (Kg)

    Diameter

    (INLET/OUTLET)

    inch

    1 1,5 1,10 23.0/ 11.5 113 3,2 192 71 1800 2,56 177 63 1600 2,27 157 75 73 33 2

    Single Stage Regenerative Blowers / 1 Phase (110 / 220 V) - 50 Hz

    Single Stage Regenerative Blowers / 1 Phase (110 / 220 V) - 60 Hz

  • All Pacific blowers are available in unassembled kits for either pressure or vacuum applications.

    These kits include:

    Vacuum* Silencer* Inlet Filter* Relief Valve* Vacuum Gauge* Flow Meter (optional)

    Pressure* Relief Valve* Check Valve* Pressure Gauge* Inlet Filter* Flow Meter (optional)* Silencer (optional)

    KVPB-301 - Vacuum Kit Drawing

    KPPB-301 - Pressure Kit Drawing

    (16,97")(24,36")

    (20,98")

    (1,9")

    2" NPT

    (16,79")

    (13,30")

    (3,43")(4,72")

    (10,24")

    (11,75")

    618,74mm

    325,85mm

    87,12mm (4,53")115mm

    532,9mm

    426,46mm

    48,26mm

    431mm

    119,88mm

    298,45mm

    260mm

    Kit Pressure Pump 2" NPT KPPB-301

    (13.27")

    (29,23")

    (16,38")

    2" NPTFEMALE

    (3,43") (4,53")

    (3,20")

    (13,30")

    (4,72")

    (11,75")

    (1,89")

    337,82mm

    87,12mm 155mm

    742,44mm 81,28mm

    337mm

    48mm

    416mm

    (10,26")260,6mm

    298,45mm

    119,9mm

    (10,24")260mm

    Kit Vacuum Pump 2" NPT KVPB-301

    Página 1Página 2Página 3