single tennis court class i a2 400w tb02 - · pdf filedisposal and with the aid of calculating...

10
Siteco Beleuchtungstechnik GmbH An Osram Business Page 1/10 Single Tennis court class I A2 400W TB02 SPORTS: Single Tennis court 24x11m for class I Installation : SiCompact A2 Midi with 400W short-arc lamp narrow beam Project number : Sample project Customer : Processed by : Siteco Light Consulting Date : 04.07.2014 Project description: Maintenance factor 0,8 Tennis court Principal Playing Area (PPA) 24 x 11m Tennis court Total Playing Area (TPA) 36 x 18m 6-mast-layout Mast height 8m 4-5 floodlights per mast Inclination 0° The determination of the lighting results is performed on a sales support basis, with great thoroughness, using the documents at our disposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). A guarantee / warranty / liability for this free calculation is not provided by SITECO. In this respect, we refer to the services of the light planning and engineering office. The following values are based on exact calculations on calibrated lamps, luminaires and their arrangement. In practice, gradual divergences can occur. Guarantee claims for luminaire data are excluded. Relux and the luminaire manufacturers accept no liability for consequential damage and damage which is occasioned to the user or to third parties.

Upload: duongdien

Post on 17-Feb-2018

219 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Single Tennis court class I A2 400W TB02 - · PDF filedisposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). ... Single Tennis court class

Siteco Beleuchtungstechnik GmbHAn Osram Business

Page 1/10Single Tennis court class I A2 400W TB02

SPORTS: Single Tennis court 24x11m for class I

Installation : SiCompact A2 Midi with 400W short-arc lamp narrow beam

Project number : Sample project

Customer :

Processed by : Siteco Light Consulting

Date : 04.07.2014

Project description:

Maintenance factor 0,8

Tennis court Principal Playing Area (PPA) 24 x 11m

Tennis court Total Playing Area (TPA) 36 x 18m

6-mast-layout

Mast height 8m

4-5 floodlights per mast

Inclination 0°

The determination of the lighting results is performed on a sales support basis, with great thoroughness, using the documents at our disposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux).A guarantee / warranty / liability for this free calculation is not provided by SITECO. In this respect, we refer to the services of the light planning and engineering office.

The following values are based on exact calculations on calibrated lamps, luminaires and their arrangement. In practice, gradual divergences can occur.

Guarantee claims for luminaire data are excluded.

Relux and the luminaire manufacturers accept no liability for consequential damage and damage which is occasioned to the user or to thirdparties.

Page 2: Single Tennis court class I A2 400W TB02 - · PDF filedisposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). ... Single Tennis court class

Table of contents

ObjectInstallationProject numberDate

: SPORTS: Single Tennis court 24x11m for class I: SiCompact A2 Midi with 400W short-arc lamp narrow beam: Sample project: 04.07.2014

Siteco Beleuchtungstechnik GmbHAn Osram Business

Page 2/10Single Tennis court class I A2 400W TB02

First Page 1Table of contents 21 Luminaire data1.1 Siteco, SiCOMPACT® A2 MIDI (5NA75871TB0208)1.1.1 Data sheet 32 Tennis court 500 lux2.1 Description, Tennis court 500 lux2.1.1 Floor plan 42.1.2 3D view, View 1 52.2 Summary, Tennis court 500 lux2.2.1 Result overview, Tennis PPA 62.2.2 Result overview, Tennis TPA 72.3 Calculation results, Tennis court 500 lux2.3.1 Table, Tennis PPA (E) 82.3.2 Table, Tennis TPA (E) 92.3.3 3D luminance, View 1 10

Page 3: Single Tennis court class I A2 400W TB02 - · PDF filedisposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). ... Single Tennis court class

1 Luminaire data

1.1 Siteco, SiCOMPACT® A2 MIDI (5NA75871TB0208)

1.1.1 Data sheet

ObjectInstallationProject numberDate

: SPORTS: Single Tennis court 24x11m for class I: SiCompact A2 Midi with 400W short-arc lamp narrow beam: Sample project: 04.07.2014

Siteco Beleuchtungstechnik GmbHAn Osram Business

Page 3/10Single Tennis court class I A2 400W TB02

Manufacturer: Siteco

5NA75871TB0208 floodlight-pylon annexe Si COMPACT® A2 MIDISiCOMPACT® A2 MIDI, floodlight, primary light control with reflector, of aluminium, highly specular, primaryoptical cover: cover panel, of toughened safety glass, light emission: direct distribution, primary lightcharacteristic: asymmetric, installation type: surface-mounted, for 1 x HIT-DE 400W, ignitor for instant hotre-ignition, control gear: LLCG, with thermal protection switch, parallel p.f. corrected, with terminal, 3-pole, max.2.5mm², mains connection: 230V, AC, 50Hz, luminaire housing, of diecast aluminium, coated, Siteco® metallicgrey (DB 702S), length: 565 mm, width: 465 mm, height: 155mm, mounting bracket, of steel, galvanised, coated,Siteco® metallic grey (DB 702S), protection rating (complete): IP66, insulation class (complete): insulation classI (protective earthing), certification: CE, ENEC in preparation, protection symbol: F, ball protection: ball impactresistant, standard: EN 50419, packaging unit: 1 piece,

Luminaire dataLuminaire efficiency : 66.1%Luminaire efficacy : 55.33 lm/W

A30 ↓ 100.0% ↑ 0.0% Classification :CIE Flux Codes : 39 84 99 100 66UGR 4H 8H (20%, 50%, 70%)C0 / C90 : 37.6 / 28.5Control gear : LLCGSystem power : 442 WLength : 565 mmWidth : 465 mmHeight : 155 mm

Equipped withQuantity : 1Designation : HIT-DE-h45

400W/960(OSRAM)

Power : 400WColour :Luminous flux : 37000 lm

Page 4: Single Tennis court class I A2 400W TB02 - · PDF filedisposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). ... Single Tennis court class

2 Tennis court 500 lux

2.1 Description, Tennis court 500 lux

2.1.1 Floor plan

ObjectInstallationProject numberDate

: SPORTS: Single Tennis court 24x11m for class I: SiCompact A2 Midi with 400W short-arc lamp narrow beam: Sample project: 04.07.2014

Siteco Beleuchtungstechnik GmbHAn Osram Business

Page 4/10Single Tennis court class I A2 400W TB02

-25 -20 -15 -10 -5 0 5 10 15 20 25[m]

1 : 500

-15.0

-12.5

-10.0

-7.5

-5.0

-2.5

0.0

2.5

5.0

7.5

10.0

12.5

15.0[m] N

Page 5: Single Tennis court class I A2 400W TB02 - · PDF filedisposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). ... Single Tennis court class

2.1 Description, Tennis court 500 lux

2.1.2 3D view, View 1

ObjectInstallationProject numberDate

: SPORTS: Single Tennis court 24x11m for class I: SiCompact A2 Midi with 400W short-arc lamp narrow beam: Sample project: 04.07.2014

Siteco Beleuchtungstechnik GmbHAn Osram Business

Page 5/10Single Tennis court class I A2 400W TB02

Page 6: Single Tennis court class I A2 400W TB02 - · PDF filedisposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). ... Single Tennis court class

2 Tennis court 500 lux

2.2 Summary, Tennis court 500 lux

2.2.1 Result overview, Tennis PPA

ObjectInstallationProject numberDate

: SPORTS: Single Tennis court 24x11m for class I: SiCompact A2 Midi with 400W short-arc lamp narrow beam: Sample project: 04.07.2014

Siteco Beleuchtungstechnik GmbHAn Osram Business

Page 6/10Single Tennis court class I A2 400W TB02

-25 -20 -15 -10 -5 0 5 10 15 20 25[m]

-15.0

-12.5

-10.0

-7.5

-5.0

-2.5

0.0

2.5

5.0

7.5

10.0

12.5

15.0[m] N

200 300 500 750 1000Illuminance [lx]

GeneralCalculation algorithm used Direct componentHeight of evaluation surface 0.00 mphotometric centre height. [m]: 8.19 mMaintenance factor 0.80

Total luminous flux of all lamps 962000 lmTotal power 11492 WTotal power per area (1500.00 m²) 7.66 W/m²

IlluminanceAverage illuminance Eav 562 lxMinimum illuminance Emin 479 lxMaximum illuminance Emax 649 lxUniformity Uo Emin/Em 1:1.17 (0.85)Diversity Ud Emin/Emax 1:1.36 (0.74)

Type No.\Make

Siteco1 26 Order No. : 5NA75871TB0208

Luminaire name : SiCOMPACT® A2 MIDIEquipment : 1 x HIT-DE-h45 400W/960 (OSRAM) 400W / 37000 lm

Page 7: Single Tennis court class I A2 400W TB02 - · PDF filedisposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). ... Single Tennis court class

2.2 Summary, Tennis court 500 lux

2.2.2 Result overview, Tennis TPA

ObjectInstallationProject numberDate

: SPORTS: Single Tennis court 24x11m for class I: SiCompact A2 Midi with 400W short-arc lamp narrow beam: Sample project: 04.07.2014

Siteco Beleuchtungstechnik GmbHAn Osram Business

Page 7/10Single Tennis court class I A2 400W TB02

-25 -20 -15 -10 -5 0 5 10 15 20 25[m]

-15.0

-12.5

-10.0

-7.5

-5.0

-2.5

0.0

2.5

5.0

7.5

10.0

12.5

15.0[m] N

200 300 500 750 1000Illuminance [lx]

GeneralCalculation algorithm used Direct componentHeight of evaluation surface 0.00 mphotometric centre height. [m]: 8.19 mMaintenance factor 0.80

Total luminous flux of all lamps 962000 lmTotal power 11492 WTotal power per area (1500.00 m²) 7.66 W/m²

IlluminanceAverage illuminance Eav 525 lxMinimum illuminance Emin 429 lxMaximum illuminance Emax 649 lxUniformity Uo Emin/Em 1:1.22 (0.82)Diversity Ud Emin/Emax 1:1.51 (0.66)

Type No.\Make

Siteco1 26 Order No. : 5NA75871TB0208

Luminaire name : SiCOMPACT® A2 MIDIEquipment : 1 x HIT-DE-h45 400W/960 (OSRAM) 400W / 37000 lm

Page 8: Single Tennis court class I A2 400W TB02 - · PDF filedisposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). ... Single Tennis court class

2 Tennis court 500 lux

2.3 Calculation results, Tennis court 500 lux

2.3.1 Table, Tennis PPA (E)

ObjectInstallationProject numberDate

: SPORTS: Single Tennis court 24x11m for class I: SiCompact A2 Midi with 400W short-arc lamp narrow beam: Sample project: 04.07.2014

Siteco Beleuchtungstechnik GmbHAn Osram Business

Page 8/10Single Tennis court class I A2 400W TB02

Height of the reference plane : 0.00 mAverage illuminance Eav : 562 lxMinimum illuminance Emin : 479 lxMaximum illuminance Emax : 649 lxUniformity Uo Emin/Eav : 1 : 1.17 (0.85)Diversity Ud Emin/Emax : 1 : 1.36 (0.74)

611 632 549 (479) 506 537 560 537 506 (479) 549 632 611

608 570 555 528 508 536 567 536 508 528 555 570 608

561 528 552 595 577 593 606 593 577 595 552 528 561

538 519 554 612 616 632 [649] 632 616 612 554 519 538

561 528 552 595 577 593 606 593 577 595 552 528 561

608 570 555 528 508 536 567 536 508 528 555 570 608

611 632 549 (479) 506 537 560 537 506 (479) 549 632 611

0 2 4 6 8 10 12 14 16 18 20 22[m]

Illuminance [lx]

0

1

2

3

4

5

6

7

8

9[m]

Page 9: Single Tennis court class I A2 400W TB02 - · PDF filedisposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). ... Single Tennis court class

2.3 Calculation results, Tennis court 500 lux

2.3.2 Table, Tennis TPA (E)

ObjectInstallationProject numberDate

: SPORTS: Single Tennis court 24x11m for class I: SiCompact A2 Midi with 400W short-arc lamp narrow beam: Sample project: 04.07.2014

Siteco Beleuchtungstechnik GmbHAn Osram Business

Page 9/10Single Tennis court class I A2 400W TB02

Height of the reference plane : 0.00 mAverage illuminance Eav : 525 lxMinimum illuminance Emin : 429 lxMaximum illuminance Emax : 649 lxUniformity Uo Emin/Eav : 1 : 1.22 (0.82)Diversity Ud Emin/Emax : 1 : 1.51 (0.66)

433 497 481 544 482 437 444 (429) 444 437 482 544 481 497 433

468 521 563 648 529 481 525 554 525 481 529 648 563 521 468

456 565 596 559 556 542 533 578 533 542 556 559 596 565 456

497 597 550 520 564 617 625 [649] 625 617 564 520 550 597 497

456 565 596 559 556 542 533 578 533 542 556 559 596 565 456

468 521 563 648 529 481 525 554 525 481 529 648 563 521 468

433 497 481 544 482 437 444 (429) 444 437 482 544 481 497 433

0 5 10 15 20 25 30[m]

Illuminance [lx]

0

2

4

6

8

10

12

14[m]

Page 10: Single Tennis court class I A2 400W TB02 - · PDF filedisposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). ... Single Tennis court class

2.3 Calculation results, Tennis court 500 lux

2.3.3 3D luminance, View 1

ObjectInstallationProject numberDate

: SPORTS: Single Tennis court 24x11m for class I: SiCompact A2 Midi with 400W short-arc lamp narrow beam: Sample project: 04.07.2014

Siteco Beleuchtungstechnik GmbHAn Osram Business

Page 10/10Single Tennis court class I A2 400W TB02

Luminance in the sceneMinimum: : 0 cd/m²Maximum: : 5040 cd/m²