Operating InstructionsIncl. Declaration of Conformity
BG 805 195 BE / B (2004-08) 1
SingleGauge™Single-Channel Measurement andControl Unit for Compact Gauges
TPG 261
VACUUM
2 BG 805 195 BE / B (2004-08) TPG261.oi
In all communications with Pfeiffer Vacuum, pleasespecify the information on the product nameplate. Forconvenient reference copy that information into thespace provided below.
Typ: No: F-No: V Hz VA
Pfeiffer Vacuum, D-35614 Asslar
This document applies to products with part numberPTG28030.The part number (No.) can be taken from the productnameplate.
This manual is based on firmware version 302-510-A.If your unit does not work as described in this document,please check that it is equipped with the above firmwareversion (→ 57).
We reserve the right to make technical changes withoutprior notice.
All dimensions are indicated in mm.
Product Identification
Validity
BG 805 195 BE / B (2004-08) TPG261.oi 3
The TPG 261 is used together with Pfeiffer VacuumCompact Gauges (in this document referred to asgauges) for total pressure measurement. All productsmust be operated in accordance with their respectiveOperating Instructions.
The scope of delivery consists of following parts:1 TPG 261 Single-Channel Measurement and Control
Unit1 Power cord1 Connector for control connection4 Collar screws and plastic sleeves2 Rubber feet1 Rubber bar1 Operating Instructions (this document)1 Betriebsanleitung
SingleGauge™ INFICON AGFullRange™ INFICON GmbH
Intended Use
Scope of Delivery
Trademarks
4 BG 805 195 BE / B (2004-08) TPG261.oi
Contents
Product Identification 2Validity 2Intended Use 3Scope of Delivery 3Trademarks 3
1 Safety 61.1 Symbols Used 61.2 Personnel Qualifications 71.3 General Safety Instructions 71.4 Liability and Warranty 82 Technical Data 93 Installation 143.1 Personnel 143.2 Installation, Setup 143.2.1 Rack Installation 143.2.2 Installation in a Control Panel 173.2.3 Use as Desk-Top Unit 183.3 Mains Power Connector 193.4 Gauge Connector sensor 203.5 control Connector 213.6 relay Connector 223.7 Interface Connector RS232 234 Operation 244.1 Front Panel 244.2 Turning the TPG 261 On and Off 254.3 Operating Modes 264.4 Measurement Mode 274.5 Parameter Mode 314.5.1 Switching Function Parameters 334.5.2 Gauge Parameters 374.5.3 Gauge Control 464.5.4 General Parameters 514.5.5 Test Parameters 55
BG 805 195 BE / B (2004-08) TPG261.oi 5
5 Communication (Serial Interface) 645.1 RS232C Interface 645.1.1 Data Transmission 645.1.2 Communication Protocol 665.2 Mnemonics 685.2.1 Measurement Mode 695.2.2 Parameter Mode 755.2.2.1 Switching Function Parameters 755.2.2.2 Gauge Parameters 765.2.2.3 Gauge Control 805.2.2.4 General Parameters 815.2.2.5 Test Parameters 825.2.3 Example 886 Maintenance 896 Troubleshooting 908 Repair 919 Storage 9210 Disposal 92
Appendix 93A: Conversion Tables 93B: Default Settings 94C: Firmware Update 95D: Literature 98E: Index 100Declaration of Conformity 102
For cross-references within this document, the symbol(→ XY) is used, for cross-references to further docu-ments, listed under "Literature", the symbol (→ [Z]).
6 BG 805 195 BE / B (2004-08) TPG261.oi
1 Safety
DANGER
Information on preventing any kind of physical injury.
WARNING
Information on preventing extensive equipment andenvironmental damage.
Caution
Information on correct handling or use. Disregard canlead to malfunctions or minor equipment damage.
The lamp/display is lit.
The lamp/display flashes.
The lamp/display is dark.
Press the key (example: PARA key).
Do not press any key.
1.1 Symbols Used
Symbols for residualrisks
Further symbols
BG 805 195 BE / B (2004-08) TPG261.oi 7
Skilled personnel
All work described in this document may only be car-ried out by persons who have suitable technical train-ing and the necessary experience or who have beeninstructed by the end-user of the product.
Adhere to the applicable regulations and take the nec-essary precautions for all work you are going to do andconsider the safety instructions in this document.
DANGER
Caution: mains voltageContact with live parts is extremely hazardouswhen any objects are introduced or any liq-uids penetrate into the unit.Make sure no objects enter through the lou-vers and no liquids penetrate into the equip-ment.
Communicate the safety instructions to all other users.
1.2 PersonnelQualifications
1.3 General SafetyInstructions
8 BG 805 195 BE / B (2004-08) TPG261.oi
Pfeiffer Vacuum assumes no liability and the warrantybecomes null and void if the end-user or third parties• disregard the information in this document• use the product in a non-conforming manner• make any kind of interventions (modifications, altera-
tions etc.) on the product• use the product with accessories not listed in the cor-
responding product documentation.
1.4 Liability andWarranty
BG 805 195 BE / B (2004-08) TPG261.oi 9
2 Technical Data
Voltage 90 … 250 VACFrequency 50 … 60 HzPower consumption ≤45 WOvervoltage category IIProtection class 1Connection European appliance connec-
tor IEC 320 C14 (→ 19)
Temperaturestorageoperation
–20 … +65 °C+ 5 … +50 °C
Relative humidity ≤80% up to +31 °C,decreasing to 50% at +40 °C
Use indoors onlymax. altitude 2000 m NN
Pollution degree IIProtection type IP30
Number 1CompatibleCompact Gauges
Pirani
Pirani CapacitanceCold CathodeFullRange™ CCProcess IonFullRange™ BACapacitancePiezo
TPR 261, TPR 265, TPR 280,TPR281PCR 260IKR 251, IKR 261, IKR 270PKR 251, PKR 261IMR 265PBR 260CMR 261 … CMR 275APR 250 … APR 267
Number 1sensor connector Amphenol C91B appliance
connector, female, 6-pole(pin assignment → 20)
Mains specifications
Ambiance
Compatible gauges
Gauge connections
10 BG 805 195 BE / B (2004-08) TPG261.oi
Voltage +24 VDC ±5%Current 750 mAPower 18 WFuse protection 900 mA with PTC element,
self-resetting after turning theTPG 261 off or disconnectingthe gauge. The supply con-forms to the requirements of agrounded protective extra lowvoltage (SELV-E according toEN 61010).
Front panelRemote control
via 3 keysvia RS232C interface
Measurement range depending on gauge(→ [1] … [14])
Measurement errorgain erroroffset error
≤0.01% F.S.≤0.01% F.S.
Measurement rate 50 / sDisplay rate 10 / sFilter time constant
slownormal (nor)fast
1.2 s (fg = 0.13 Hz)400 ms (fg = 0.4 Hz) 20 ms (fg = 8 Hz)
Measurement units mbar, Pa, TorrOffset correction for linear gauges
–5 … 110% F.S.Calibration factor for logarithmic gauges
0.10 … 9.99for linear gauges0.500 … 2.000
A/D converter resolution 0.001% F.S.
Gauge supply
Operation
Measurement values
BG 805 195 BE / B (2004-08) TPG261.oi 11
Number 2Reaction delay ≤20 ms if switching threshold
close to measurement value(for larger differences con-sider filter time constant)
Adjustment range depending on gauge(→ [1] … [14])
Hysteresis ≥1% F.S. for linear gauges,≥10% of measurement valuefor logarithmic gauges
Contact type floating changeover contactLoad max. 30 VAC, 30 W (ohmic)
60 VDC, 1 A, 30 W (ohmic)Service life
mechanicelectric
5×107 cycles1×105 cycles (at max. load)
Contact positions → 22Relay connector D-Sub appliance connector,
female, 15-pole(pin assignment → 22)
Number 1Reaction time ≤20 ms
Contact type floating normally open contactLoad max. 30 VAC, 30 W (ohmic)
60 VDC, 1 A, 30 W (ohmic)Service life
mechanicelectric
5×107 cycles1×105 cycles (at max. load)
Contact positions → 21Control connector Amphenol C91B appliance
connector, female, 7-pole(pin assignment → 21)
Switching functions
Switching function relays
Error signal
Error signal relay
12 BG 805 195 BE / B (2004-08) TPG261.oi
Manualvia keysactivation/deactivation (→ 28, 48, 49)
Externalvia control connectorON conditionOFF condition
signal ≤ +0.8 VDCsignal +2.0 … 5 VDC or inputopen
Hotstartwhen mains power on (→ 48)
Self controldeactivation whenpressure risesOFF threshold adjustable (→ 50)
Control connector Amphenol C91B applianceconnector, female, 7-pole(pin assignment → 21)
Number 1Voltage range 0 … +10 VDCInternal resistance 660 ΩMeasuring signal vs.pressure
depending on gauge(→ [1] … [14])
Control connector Amphenol C91B applianceconnector, female, 7-pole(pin assignment → 21)
Standard RS232CProtocol ACK/NAK, ASCII with
3-character mnemonics,bi-directional data flow,8 data bits, no parity bit,1 stop bit
RS232C only TXD and RXD usedTransmission rate 9600, 19200, 38400 baudRS232 connector D-Sub appliance connector,
male, 9-pole(pin assignment → 23)
Gauge control
Analog output
Interface
BG 805 195 BE / B (2004-08) TPG261.oi 13
228.5 2.5≈310
111.
6
68.1
VACUUM
ø3.555.970.8
122.
512
8.5
For incorporation into a rack or control panel or as desk-top unit.
1.1 kg
Dimensions [mm]
Use
Weight
14 BG 805 195 BE / B (2004-08) TPG261.oi
3 Installation
Skilled personnel
The unit may only be installed by personswho have suitable technical training and thenecessary experience or who have been in-structed by the end-user of the product.
The TPG 261 is suited for incorporation into a 19" rackor a control panel or for use as desk-top unit.
DANGER
Caution: damaged productPutting a damaged product into operation canbe extremely hazardous.In case of visible damages, make sure theproduct is not put into operation.
The TPG 261 is designed for installation into a 19" rackchassis adapter according to DIN 41 494. For this pur-pose, four collar screws and plastic sleeves are suppliedwith it.
DANGER
Caution: protection class of the rackIf the product is installed in a rack, it is likelyto lower the protection class of the rack(protection against foreign bodies and water)e.g. according to the EN 60204-1 regulationsfor switching cabinets.Take appropriate measures for the rack tomeet the specifications of the protectionclass.
3.1 Personnel
3.2 Installation, Setup
3.2.1 Rack Installation
BG 805 195 BE / B (2004-08) TPG261.oi 15
In order to reduce the mechanical strain on the frontpanel of the TPG 261, preferably equip the rack chassisadapter with a guide rail.
For safe and easy installation of heavy rack chassisadapters, preferably equip the rack frame with slide rails.
Guide rail
Slide rails
16 BG 805 195 BE / B (2004-08) TPG261.oi
Secure the rack adapter in the rack frame.
The admissible maximum ambient tem-perature (→ 9) must not be exceededneither the air circulation obstructed.
Rack chassis adapterHeight 3 U
Slide the TPG 261 into the rack chassis adapter …
… and fasten the adapter panel to the rack chas-sis adapter using the screws supplied with theTPG 261.
Height 3 U rackchassis adapter
BG 805 195 BE / B (2004-08) TPG261.oi 17
DANGER
Caution: protection class of the control panelIf the product is installed in a control panel, itis likely to lower the protection class of thecontrol panel (protection against foreignbodies and water) e.g. according to theEN 60204-1 regulations for switching cabi-nets.Take appropriate measures for the controlpanel to meet the specifications of the pro-tection class.
For mounting the TPG 261 into a control panel, the fol-lowing cut-out is required:
M3 or ø 3.5
122.
5
113
70
55.9
The admissible maxi-mum ambient tem-perature (→ 9) mustnot be exceeded nei-ther the air circulationobstructed.
For reducing the mechanical strain on the front panel,preferably support the unit.
3.2.2 Installation in aControl Panel
18 BG 805 195 BE / B (2004-08) TPG261.oi
Slide the TPG 261 into the cut-out of the controlpanel …
… and secure it with four M3 or equivalent screws.
The TPG 261 is also suited for use as desk-top unit. Forthis purpose, two self-adhesive rubber feet as well as aslip-on rubber bar are supplied with it.
Stick the two supplied rubber feet to the rear partof the bottom plate …
… and slip the supplied rubber bar onto the bot-tom edge of the front panel.
3.2.3 Use as Desk-TopUnit
BG 805 195 BE / B (2004-08) TPG261.oi 19
Select a location where the admissible maxi-mum ambient temperature (→ 9) is not ex-ceeded (e.g. due to sun irradiation).
DANGER
Caution: line voltageIncorrectly grounded products can be ex-tremely hazardous in the event of a fault.Use only a 3-conductor power cable withprotective ground. The power connector mayonly be plugged into a socket with a protec-tive ground. The protection must not be nulli-fied by an extension cable without protectiveground.
The unit is supplied with a power cord. If the mains con-nector is not compatible with your system, use your own,suitable cable with protective ground (3×1.5 mm3).
The socket must befuse-protected with
10 Amax
If the unit is installed in a switching cabinet, the mainsvoltage should be supplied and turned on via a centraldistributor.
3.3 Mains PowerConnector
20 BG 805 195 BE / B (2004-08) TPG261.oi
Do not unfastenthis screw
(internal groundprotection)
Connect the gauge to the sensor connector viaa sensor cable set available from us (→ salesliterature) or your own, screened (electromag-netic compatibility) sensor cable. Make sure thegauge you are connecting is compatible(→ 9).
Pin assignment ofthe female 6-poleAmphenol C91B ap-pliance connector:
1
2
3
4
56
1 2
5 4
6 3
Pin Signal 1 6 2 3 4 5
IdentificationSupply +24 VDCSupply common GNDSignal input (measuring signal+)Signal common (measuring signal–)Screening
3.4 Gauge Connectorsensor
Pin assignmentsensor
BG 805 195 BE / B (2004-08) TPG261.oi 21
This connector allows to read the measuring signal, toevaluate the state of the floating contacts of the errorrelay, and to activate or deactivate the gauge (→ 46).
Connect the peripheral components to thecontrol connector on the rear of the unit usingyour own, screened (electromagnetic compati-bility) cable.
Pin assignment ofthe female 7-poleAmphenol C91B ap-pliance connector:
13
25
4
67
8
6 4
7 5
8 2
1
3
Pin Signal 2 5 4
1, 6
Analog output gauge 0 … +10 VDCScreening GNDGauge on signal ≤+0.8 VDC
off signal +2.0 … 5 VDC or input openNot assigned
3 7 No error
Error or powersupply turned off
A suitable connector is supplied with the TPG 261.
3.5 control Connector
Pin assignmentContact positionscontrol
22 BG 805 195 BE / B (2004-08) TPG261.oi
This connector allows to use the floating switching con-tacts for an external control system.
Connect the peripheral components to the relayconnector on the rear of the unit using yourown, screened (electromagnetic compatibility)cable.
Pin assignment ofthe female 15-poleD-Sub applianceconnector:
15
9
8
1
Pin Signal
Switching function 1 4 3 2
Pressure belowthreshold
Pressure abovethreshold or powersupply turned off
Switching function 2 7 6 5
Pressure belowthreshold
Pressure abovethreshold or powersupply turned off
9 … 14 Not connected
Supply for relays with higher switching power
15 1 8
+24 VDC, 200 mAGNDGND
Fuse-protected at 300 mA with PTCelement, self-resetting after poweroff or pulling the relay connector.Meets the requirements of agrounded protective extra low volt-age (SELV-E according toEN 61010).
3.6 relay Connector
Pin assignmentContact positionsrelay
BG 805 195 BE / B (2004-08) TPG261.oi 23
The RS232C interface allows for operating the TPG 261via a HOST or terminal (→ 64). It can also be used forupdating the firmware (→ 95).
Connect the serial interface to the RS232 con-nector on the rear of the unit using your own,screened (electromagnetic compatibility) cable.
e.g. PC TPG 261
Chassis2 RXDRXD3 TXDTXD5 GND
Chassis
GND
(Minimum configuration)
Pin assignment ofthe male 9-poleD-Sub applianceconnector:
5
1
9
6
Screening
Pin Signal Pin Signal
2 3 5
RXDTXDGND
1 6 9
not connectednot connectednot connected
4 7 8
DTRRTSCTS
Casing = screening
3.7 Interface ConnectorRS232
Pin assignmentRS232
24 BG 805 195 BE / B (2004-08) TPG261.oi
4 Operation
VACUUM
Degas activated
Measurement value in floating point orexponential format or status messages
Measurementunit
Parameter modeactivated
Warning/error(flashing)
Operator keys
Switching function status
Offset value ≠ 0Correction factor ≠ 1
Gauge activatedNo function
4.1 Front Panel
BG 805 195 BE / B (2004-08) TPG261.oi 25
Make sure the TPG 261 is correctly installed and thespecifications in the Technical Data are met.
The power switch is on therear of the unit.Turn the TPG 261 on withthe power switch (or cen-trally, via a switched powerdistributor, if the unit is in-corporated in a rack).
After power on, the TPG 261 …• automatically performs a self-test• identifies the connected gauge• activates the parameters that were in effect before
the last power off• switches to the Measurement mode• adapts the parameters if required (if another gauge
was previously connected).
Turn the TPG 261 off with the power switch (or centrally,via a switched power distributor, if the unit is incorpo-rated in a rack).
Wait at least 10 s before turning the TPG 261on again in order for it to correctly initialize it-self.
4.2 Turning theTPG 261 On and Off
Turning the TPG 261on
Turning the TPG 261off
26 BG 805 195 BE / B (2004-08) TPG261.oi
The TPG 261 works in the following operating modes:• Measurement mode
for displaying measurement values or statuses(→ 27)
• Parameter modefor displaying or editing parameters (→ 31)− Switching function parameter group
for entering or displaying thresholds (→ 33)− Gauge parameter group
for entering or displaying gauge parameters(→ 37)
− Gauge control group for entering or displaying gauge control parame-ters (→ 46)
− General parameter group for entering or displaying general parameters(→ 51)
− Test program group for running internal test programs (→ 55)
• Program transfer modefor updating the firmware (→ 95)
4.3 Operating Modes
BG 805 195 BE / B (2004-08) TPG261.oi 27
The Measurement mode is the standard operating modeof the TPG 261. Measurement values and statuses aswell as the gauge identification are displayed in thismode.
Parametermode
>10 s
Measurement mode
Status
Power on
Measurement value
Gauge identification
dependingon history
4.4 Measurement Mode
28 BG 805 195 BE / B (2004-08) TPG261.oi
Certain gauges can be turned on and off manually, if thegauge control is set to (→ 49).Available for:
Pirani Gauge (TPR)Pirani Capacitance Gauge (PCR)Cold Cathode Gauge (IKR)FullRange™ CC Gauge (PKR)Process Ion Gauge (IMR)FullRange™ BA Gauge (PBR)Capacitance Gauge (CMR)Piezo Gauge (APR)
Press key >1 s:The gauge isturned off.
is dis-played instead ofthe measurementvalue.Press key >1 s:The gauge isturned on. A statusmessage may bedisplayed insteadof the measure-ment value.
Turning the gauge onand off
30 BG 805 195 BE / B (2004-08) TPG261.oi
Press keys >0.5 s:The type of the connectedgauge is automatically iden-tified and displayed for 4 s:
Pirani Gauge(TPR 261, TPR 265, TPR 280,TPR 281)Pirani Capacitance Gauge 1)
(PCR 260)
Cold Cathode Gauge(IKR251, IKR261)
Cold Cathode Gauge(IKR270)
FullRange™ CC Gauge(PKR251, PKR261)
Process Ion Gauge(IMR265)
FullRange™ BA Gauge(PBR260)
Capacitance Gauge(CMR261 … CMR275)
Piezo Gauge(APR250 … APR267)
No gauge connected(no Sensor)
Connected gauge cannot beidentified (no Identifier)
1) TPR and PCR have identical identifiers. Inthe TPG 261, there is no distinction made onthe display and in data evaluation, since pres-sure ranges of these gauges are approximatelythe same.
→ 31
Displaying the gaugeidentification
Getting to theParameter mode
BG 805 195 BE / B (2004-08) TPG261.oi 31
The Parameter mode is used for displaying, editing andentering parameter values as well as for testing theTPG 261. For ease of operation, the parameters are di-vided into groups.
Power on
Parameter mode
dependingon history
Switching function parameters
Gauge parameters
Gauge control
General parameters
Test parameters>10 s
Measurementmode
4.5 Parameter Mode
32 BG 805 195 BE / B (2004-08) TPG261.oi
Switching function parame-ters → 33Gauge parameters → 37Gauge control → 46General parameters→ 51Test parameters→ 55
Modifications of parameters come into effect immedi-ately and are stored automatically. Exceptions are men-tioned under the corresponding parameters.
Selecting a parametergroup
Selecting a parameterin a parameter group
Editing a parameter ina parameters group
BG 805 195 BE / B (2004-08) TPG261.oi 33
The switching function parametergroup (setpoint parameters) isused for displaying, entering andediting threshold values of the twoswitching functions.
Mea
surm
ent m
ode
Parameter modedependingon history
Switching function 1 lower threshold
Switching function 1 upper threshold
Switching function 2 lower threshold
Swiching function 2 upper threshold
>10 s
4.5.1 SwitchingFunctionParameters
34 BG 805 195 BE / B (2004-08) TPG261.oi
The TPG 261 has two switching functions with two ad-justable thresholds each. The status of the switchingfunction is displayed on the front panel (→ 24, 21) andcan be evaluated via the floating contacts at the relayconnector.
Pres
sure
pSw
itchi
ngfu
nctio
n
On Off
Time t
Off234
234
234
Dis
play
Measurement value
The name of the parameter,
e.g.:Switching function 1lower setpoint
is displayed as long as thekey is pressed or at least for1.5 s.Afterwards, the currentlyvalid threshold value is dis-played.
Selecting a parameter
BG 805 195 BE / B (2004-08) TPG261.oi 35
Press key <1 s:The value is increased/decreased by 1 increment.
Press key >1 s:The value is increased/decreased continuously.
Value
The lower switching threshold(Setpoint low) defines the pres-sure at which the switching func-tion is activated when the pres-sure is dropping.
e.g.: Gauge dependent (→ table).If another gauge type is con-nected, the TPG 261 automati-cally adjusts the switchingthreshold if required.
low
erth
resh
old
limit
uppe
rth
resh
old
limit
1×10-2
1000
5×10-4
1×10-9
1×10-6
10005×10-10
all values in mbar, CAL=1
1×10-21×10-11
10001×10-9
1500
F.S. / 1000 F.S.
Editing the thresholdvalue
Limits of the lowerswitching thresholds
36 BG 805 195 BE / B (2004-08) TPG261.oi
The minimum hysteresis between the upperand lower switching threshold is at least 10% ofthe lower threshold or 1% of the set full scalevalue. If the value of the minimum hysteresisdrops below these values, the upper thresholdis automatically adjusted to a minimum hystere-sis. This prevents unstable states.
Value
The upper switching threshold(Setpoint high) defines the pres-sure at which the switching func-tion is deactivated when the pres-sure is rising.
e.g.: Gauge dependent (→ table).If another gauge type is con-nected, the TPG 261 automati-cally adjusts the threshold ifrequired.
+10% lower threshold
low
er th
resh
old
1500
1×10-2
1000
+10% lower threshold
+10% lower threshold
+10% lower threshold
1000
all values in mbar, CAL=1
uppe
rth
ersh
old
limit
low
erth
resh
old
limit
1×10-2+10% lower threshold
1000+10% lower threshold
F.S.+1% measurementrange (F.S.)
The minimum hysteresis between the upperand lower switching threshold is at least 10% ofthe lower threshold or 1% of the set full scalevalue. This prevents unstable states.
Limits of the upperswitching thresholds
BG 805 195 BE / B (2004-08) TPG261.oi 37
The Gauge parameter group(sensor parameters) is used fordisplaying, entering and editingparameters of the connectedgauge.
Mea
sure
men
t mod
edependingon history
Filter time constant
Calibration factor
Measurement range
Offset
Penning Underrange Control
Degas
Parameter mode
>10 s
4.5.2 Gauge Parameters
38 BG 805 195 BE / B (2004-08) TPG261.oi
The name of the parameter,
e.g.:Filter time constant
is displayed as long as thekey is pressed or at least for1.5 s.Afterwards, the currentlyvalid parameter value is dis-played.
Some parameters are not available for all gauges andthus not always displayed.
→ 38 40 41 42 43 45
*) depending on pressure
*)
*)Ava
ilabl
e fo
r
The measurement value filter permits a better evaluationof unstable or disturbed measuring signals.
The measurement value filter does not affectthe analog output (→ 21).
Selecting a parameter
Measurement valuefilter
BG 805 195 BE / B (2004-08) TPG261.oi 39
Value
Fast:The TPG 261 responds quicklyto fluctuations of the measure-ment value. As a result, it willrespond faster to interferencein measured values.
Pressure p
Time t
Normal:Good relationship between re-sponse and sensitivity of thedisplay and the switching func-tions to changes in the meas-ured values.
Pressure p
Time t
Slow:The TPG 261 does not re-spond to small changes inmeasured values. As a result,it will respond more slowly tochanges in the measured val-ues.
Pressure p
Time t
40 BG 805 195 BE / B (2004-08) TPG261.oi
The value is increased/decreased by the defined in-crements.
The calibration factor allows the measured value to becalibrated for other gases than N2 (→ characteristiccurves in [1] … [12]).Available for:
Pirani Gauge (TPR)Pirani Capacitance Gauge (PCR)Cold Cathode Gauge (IKR)FullRange™ CC Gauge (PKR)Process Ion Gauge *) (IMR)FullRange™ BA Gauge **) (PBR)Capacitance Gauge (CMR)Piezo Gauge (APR)*) only for pressures <1×10-2 mbar.**) only for pressures <1×10-1 mbar.
Value
e.g.: No correction
e.g.: Measurement valuecorrected by a factorof 0.10 … 9.99(logarithmic gauges).Measurement valuecorrected by a factorof 0.500 … 2.000(linear gauges).
Calibration factor
BG 805 195 BE / B (2004-08) TPG261.oi 41
Press key <1 s:The value is increased/decreased by 1 increment.
Press key >1 s:The value is increased/decreased continuously.
For linear gauges, the full scale (F.S.) value has to bedefined according to the connected gauge type. Forlogarithmic gauges it is automatically recognized.Available for:
Pirani Gauge (TPR)Pirani Capacitance Gauge (PCR)Cold Cathode Gauge (IKR)FullRange™ CC Gauge (PKR)Process Ion Gauge (IMR)FullRange™ BA Gauge (PBR)Capacitance Gauge (CMR)Piezo Gauge (APR)
Value
e.g.: 0.01 mbar0.1 mbar1 mbar10 mbar100 mbar1000 mbar2 bar5 bar10 bar50 barConversion table→ Appendix 93
The value is increased/decreased by the defined in-crements.
Measurement range(F.S.) of lineargauges
42 BG 805 195 BE / B (2004-08) TPG261.oi
The offset value is displayed and readjusted accordingto the actual measurement value (in the range of-5 … +110% of the set full scale value).Available for:
Pirani Gauge (TPR)Pirani Capacitance Gauge (PCR)Cold Cathode Gauge (IKR)FullRange™ CC Gauge (PKR)Process Ion Gauge (IMR)FullRange™ BA Gauge (PBR)Capacitance Gauge (CMR)Piezo Gauge (APR)
The offset correction affects:the displayed measurement valuethe displayed threshold value of the switching functionsthe analog output at the control connector (→ 21)
Value
Offset correctiondeactivated
e.g.: Offset correctionactivated
Press key >1.5 s:The offset value is read-justed. The actual measure-ment value is accepted asnew offset value.
Reset the offset value.
When the offset correction is activated, the saved offsetvalue is subtracted from the actual measurement value.This allows measuring relative to a reference pressure.
When the zero of the gauge is readjusted, theoffset correction must be deactivated.
Offset correction
BG 805 195 BE / B (2004-08) TPG261.oi 43
Behavior in the event of an underrange with Cold Cath-ode Gauges (Penning underrange control).Available for:
Pirani Gauge (TPR)Pirani Capacitance Gauge (PCR)Cold Cathode Gauge (IKR)FullRange™ CC Gauge (PKR)Process Ion Gauge (IMR)FullRange™ BA Gauge (PBR)Capacitance Gauge (CMR)Piezo Gauge (APR)
There is a number of possible causes of an underrange:• the pressure in the vacuum system is lower than the
measurement range• the measurement element has not ignited (yet)• the discharge has failed• a defect has occurred
Caution
Caution: relay is switchingAn underrange can lead to unintended reac-tions of the connected control system.Prevent false control signals and messagesby disconnecting the sensor and control ca-bles.
Underrange control
44 BG 805 195 BE / B (2004-08) TPG261.oi
Value
Underrange state is interpretedas admissible measurementvalue. is displayed.The switching function remainsON.Underrange state is interpretedas inadmissible measurementvalue. is displayed.The switching functionchanges to OFF.
Activate/deactivate theunderrange control.
If chances are that the pressure in the vacuumsystem drops below the measurement range ofthe gauge, it is advisable to select .
If is selected, the evaluation of theswitching function is suppressed for approx.10 seconds when the gauge is turned on andeach time after an underrange has occurred.During this time, the switching function remainsOFF.
BG 805 195 BE / B (2004-08) TPG261.oi 45
Contamination deposits on the electrode system of hotcathode gauges may cause instabilities of the measure-ment values. The Degas function allows to clean theelectrode system.Available for:
Pirani Gauge (TPR)Pirani Capacitance Gauge (PCR)Cold Cathode Gauge (IKR)FullRange™ CC Gauge (PKR)Process Ion Gauge (IMR)FullRange™ BA Gauge (PBR )Capacitance Gauge (CMR)Piezo Gauge (APR)
Value
Normal operation.
Degas: The electroncollection grid isheated to ≈700 °C byelectron bombard-ment and the elec-trode system is thuscleaned.
Start degas.Duration of the Degas func-tion 3 min. (can be aborted).
Abort degas.
Degas
46 BG 805 195 BE / B (2004-08) TPG261.oi
The Gauge control group (controlparameters) is used for display-ing, entering and editing parame-ters which define the activation/deactivation of the connectedgauge.
If the connected gaugecannot be controlled(→ 48), this group isnot available.
dependingon history
Gauge deactivation
OFF threshold
Parameter mode
>10 s
Gauge activation
Mea
sure
men
t mod
e
4.5.3 Gauge Control
BG 805 195 BE / B (2004-08) TPG261.oi 47
The name of the parameter,
e.g.:Gauge activation
is displayed as long as thekey is pressed or at least for1.5 s.Afterwards, the currentlyvalid parameter value is dis-played.
Some parameters are not available for all gauges andthus not always displayed.
→ 48 49 50
Avai
labl
e fo
r
Selecting a parameter
48 BG 805 195 BE / B (2004-08) TPG261.oi
Certain gauges can be activated by different means.The following gauges can be controlled:
Pirani Gauge (TPR)Pirani Capacitance Gauge (PCR)Cold Cathode Gauge (IKR)FullRange™ CC Gauge (PKR)Process Ion Gauge (IMR)FullRange™ BA Gauge (PBR)Capacitance Gauge (CMR)Piezo Gauge (APR)
Value
Manual activation:The gauge can be activated bypressing the key.External activation:The gauge is activated by aninput signal fed via the controlconnector (→ 21).Hotstart:The gauge is automatically ac-tivated when the TPG 261 isturned on. Measurement isthus automatically resumedafter a power failure. Gaugedeactivation → 49.
Increase/decrease the valueby the defined increments.
Gauge activation
BG 805 195 BE / B (2004-08) TPG261.oi 49
Certain gauges can be deactivated by different means.The following gauges can be controlled:
Pirani Gauge (TPR)Pirani Capacitance Gauge (PCR)Cold Cathode Gauge (IKR)FullRange™ CC Gauge *) (PKRx)Process Ion Gauge *) (IMR)FullRange™ BA Gauge *) (PBR)Capacitance Gauge (CMRx)Piezo Gauge (APR)*) except for self control
Value
Manual deactivation:The gauge is deactivated bypressing the key.External deactivation:The gauge is deactivated byan input signal fed via thecontrol connector (→ 21).
Additionally for ColdCathode Gauge:
Self control:The gauge deactivates itselfwhen the pressure rises(→ 50).
Increase/decrease the valueby the defined increments.
Gauge deactivation
50 BG 805 195 BE / B (2004-08) TPG261.oi
Definition of the OFF threshold for the gauge to be de-activated by itself (self control).Available for:
Pirani Gauge (TPR)Pirani Capacitance Gauge (PCR)Cold Cathode Gauge (IKRx)FullRange™ CC Gauge (PKR)Process Ion Gauge (IMR)FullRange™ BA Gauge (PBR)Capacitance Gauge (CMR)Piezo Gauge (APR)
Adjustment range
e.g.:
10-5…10-2 mbar, CAL=1
Press key <1 s:The value is increased/decreased by 1 increment.
Press key >1 s:The value is increased/decreased continuously.
OFF threshold
BG 805 195 BE / B (2004-08) TPG261.oi 51
The General parameter group(general parameters) is used fordisplaying, entering and editinggenerally applicable system pa-rameters.
Measurement unit
Transmission rate
Display resolution
Default settings
Parameter mode
>10 s
dependingon historyM
easu
rem
ent m
ode
4.5.4 GeneralParameters
52 BG 805 195 BE / B (2004-08) TPG261.oi
The name of the parameter
e.g.:Measurement unit
is displayed as long as thekey is pressed or at least for1.5 s.Afterwards, the currentlyvalid parameter value is dis-played.
The parameters are available for all gauge types andthus always displayed.
→ 53 53 54 54
Ava
ilabl
e fo
r
all gauges
Increase/decrease the valueby the defined increments.
Selecting a parameter
Editing a parameter
BG 805 195 BE / B (2004-08) TPG261.oi 53
Unit of measured values, thresholds etc. See Appendix(→ 93) for conversion.
Value
mbar/bar
Torr (only available ifTorr lock is not activatedi.e. Torr is notsuppressed → 58)
Pascal
Transmission rate of the RS232C interface.
Value
e.g.: 9600 baud19200 baud38400 baud
Measurement unit
Transmission rate
54 BG 805 195 BE / B (2004-08) TPG261.oi
Display resolution of measured values.
Value
Display• rounded to one
decimal digit• or two integrals
Display• rounded to two
decimal digits• or three inte-
grals
All user parameter settings are replaced by the factorysettings.
Loading of the default parameter settings is ir-reversible.
Value
The default values are loaded(→ 94).
Display resolution
Default settings
BG 805 195 BE / B (2004-08) TPG261.oi 55
The Test parameter group is usedfor displaying the firmware ver-sion, entering and editing specialparameter values, and for runningtest programs.
This group is only avail-able if the key waspressed while theTPG 261 was turned on.
Mea
sure
men
t mod
e
Firmware version
Watchdog control
Keylock
RAM test program
RS232C test program
Parameter mode
Poweron
dependingon history
4.5.5 Test Parameters
56 BG 805 195 BE / B (2004-08) TPG261.oi
The name of the parameter
e.g.:Firmware version
is displayed.
The parameters are available for all gauge types andthus always displayed.
→ 57 57 58 58A
vaila
ble
for
all g
auge
s
The name of the parameter is dis-played as long as the key is pressedor at least for 1.5 s.
The firmware version is continuously displayed.
→ 59 59 60 60 61 61 62 63
Ava
ilabl
e fo
ral
l gau
ges
The name of the test program is displayed untilit is started.
Increase/decrease the valueby the defined increments.
Selecting a parameter
Editing a parameter
BG 805 195 BE / B (2004-08) TPG261.oi 57
Start test program.
The firmware version (program version) is displayed.
Version
The two parts of the firmwarenumber are displayed alter-nately.
The last character indicates the modifi-cation index (-, A … Z). Please mentionthis index when contactingPfeiffer Vacuum in the event of a prob-lem.
Behavior of the system control (watchdog) in the eventof an error.
Setting
The system automatically ac-knowledges error messages ofthe watchdog after 2 s.Error messages of the watch-dog have to be acknowledgedby the operator.
Starting the testprogram
Firmware version
Watchdog control
58 BG 805 195 BE / B (2004-08) TPG261.oi
The measurement unit can be suppressed in thecorresponding parameter setting (→ 53).
Setting
Measurement unit avail-able.
Measurement unit notavailable.
The entry lock function prevents inadvertent entries inthe Parameter mode and thus malfunctions.
Setting
Entry lock function disabled.
Entry lock function enabled. is displayed when
the user attempts to edit a set-ting in the Parameter mode.
Torr lock
Keylock
BG 805 195 BE / B (2004-08) TPG261.oi 59
Test of the main memory.
Test sequence
The test runs automatically onetime:
Test in process (very briefly).
Test finished, no error found.
Test finished, error(s) found.The lamp flashes.If the error message persistsafter several test sequenceshave been run, please contactyour local Pfeiffer Vacuumservice center.
Test of the program memory.
Test sequence
The test runs automatically onetime:
Test in process
Test finished, no error found.After the test, a four-digitchecksum (hexadecimal for-mat) is displayed.Test finished, error(s) found.After the test, a four-digitchecksum (hexadecimal for-mat) is displayed. The lamp flashes.If the error message persistsafter several test sequenceshave been run, please contactyour local Pfeiffer Vacuumservice center.
RAM test
EPROM test
60 BG 805 195 BE / B (2004-08) TPG261.oi
Test of the parameter memory.
Test sequence
The test runs automatically onetime:
Test in process (very briefly).
Test finished, no error found.
Test finished, error(s) found.The lamp flashes.If the error message persistsafter several test sequenceshave been run, please contactyour local Pfeiffer Vacuumservice center.
Test of the display.
Test sequence
The test runs automati-cally one time*):
First, all display ele-ments are lit at thesame time, ...
:
... and then, each ele-ment is lit individually.
*) Stop the test sequenceand activate one elementafter another by pressingthe key once per element.
EEPROM test
Display test
BG 805 195 BE / B (2004-08) TPG261.oi 61
Test of channel 0 of the analog/digital converter (with areference voltage at the signal input of the sensor con-nector (→ 20)).
If the signal input is open, the TPG 261 dis-plays a default value that may easily fluctuatebecause of the high sensitivity of the openmeasurement circuit.
Test sequence
e.g.: Measuring signal in Volt.
Test of channel 1 of the analog/digital converter (with areference voltage at the signal input of the sensor con-nector (→ 20)).
If the signal input is open, the TPG 261 dis-plays a default value that may easily fluctuatebecause of the high sensitivity of the openmeasurement circuit.
Test sequence
e.g.: Gauge identification voltage.
No gauge connected.
A/D converter test 0
A/D converter test 1
62 BG 805 195 BE / B (2004-08) TPG261.oi
Test of the relays of the TPG 261. The program teststheir switching function.
Caution
Caution: The relays switch irrespective of thepressureStarting a test program may cause unwantedeffects in connected control systems.Disconnect all sensor and control systemlines to ensure that no control commands ormessages are triggered by mistake.
The relays switch on and off cyclically. The switchingoperations are indicated optically and can be heard.The contacts of the switching functions 1 … 4 are con-nected to the relay connector (→ 22), the contacts ofthe error relay to the control connector (→ 21) on therear of the housing. Check their function with an ohm-meter.
Test sequence
The test runs automatically onetime:
All relays deactivated
Switching function relay 1
Switching function relay 2
: No function
I/O test
BG 805 195 BE / B (2004-08) TPG261.oi 63
No function
Gauge relay
No function
Error relay
Test of the RS232C interface. The TPG 261 repeatseach sign transmitted by the communicating HOST.
The data transferred from/to the TPG 261 canbe displayed by the computer only (→ 64).
Test sequence
The test runs automatically.
RS232C test
64 BG 805 195 BE / B (2004-08) TPG261.oi
5 Communication (Serial Interface)
The serial interface is used for communication betweenthe TPG 26x 1) and a computer. A terminal can be con-nected for test purposes.When the TPG 26x is put into operation, it starts trans-mitting measured values in intervals of 1 s. As soon asthe first character is transferred to the TPG 26x, theautomatic transmission of measured values stops. Afterthe necessary inquiries or parameter modifications havebeen made, the transmission of measured values can bestarted again with the COM command (→ 71).
Pin assignment of the 9-pole D-Sub connector andRS232 interface cable → 23.
The data transmission is bi-directional, i.e. data andcontrol commands can be transmitted in either direction.
1 start bit8 data bitsNo parity bit1 stop bitNo hardware handshake
1) Communication structure and procedures are identi-cal for both controllers TPG 261 and TPG 262.Therefore the term TPG 26x is used in this chapter.
5.1 RS232C Interface
Connection diagramconnection cable
5.1.1 Data Transmission
Data format
BG 805 195 BE / B (2004-08) TPG261.oi 65
The following abbreviations and symbols are used:
Symbol MeaningHOST Computer or terminal[...] Optional elementsASCII American Standard Code for Information
InterchangeDec. Hex.
<ETX> END OF TEXT (CTRL C)Reset the interface
3 03
<CR> CARRIAGE RETURNGo to beginning of line
13 0D
<LF> LINE FEEDAdvance by one line
10 0A
<ENQ>
ENQUIRYRequest for data transmission
5 05
<ACK> ACKNOWLEDGEPositive report signal
6 06
<NAK> NEGATIVE ACKNOWLEDGENegative report signal
21 15
"Transmit": Data transfer from HOST to TPG 26x"Receive": Data transfer from TPG 26x to HOST
After each ASCII string, the HOST must wait for a reportsignal (<ACK><CR><LF> or <NAK> <CR><LF>).The input buffer of the HOST must have a capacity of atleast 32 bytes.
Definitions
Flow Control
66 BG 805 195 BE / B (2004-08) TPG261.oi
Messages are transmitted to the TPG 26x as ASCIIstrings in the form of mnemonic operating codes andparameters. All mnemonics comprise three ASCII char-acters.Spaces are ignored. <ETX> (CTRL C) clears the inputbuffer in the TPG 26x.
HOST TPG 26x ExplanationMnemonics[and parameters] ><CR>[<LF>] >
Receives messagewith "end of mes-sage"
< <ACK><CR><LF> Positive acknowledg-ment of a receivedmessage
When requested with a mnemonic instruction, theTPG 26x transmits the measurement data or parametersas ASCII strings to the HOST.<ENQ> must be transmitted to request the transmissionof an ASCII string. Additional strings, according to thelast selected mnemonic, are read out by repetitivetransmission of <ENQ>.If <ENQ> is received without a valid request, theERROR word is transmitted.
5.1.2 CommunicationProtocol
Transmission format
Transmissionprotocol
Reception format
BG 805 195 BE / B (2004-08) TPG261.oi 67
HOST TPG 26x ExplanationMnemonics[and parameters] ><CR>[<LF>] >
Receives messagewith "end of mes-sage"
< <ACK><CR><LF> Positive acknowledg-ment of a receivedmessage
<ENQ> > Requests to transmitdata
< Measurement valuesor parameters
< <CR><LF>
Transmits data with"end of message"
: :<ENQ> > Requests to transmit
data< Measurement values
or parameters< <CR><LF>
Transmits data with"end of message"
The strings received are verified in the TPG 26x. If anerror is detected, a negative acknowledgment <NAK> isoutput.
HOST TPG 26x ExplanationMnemonics[and parameters] ><CR>[<LF>] >
Receives messagewith "end of mes-sage"
***** Transmission or programming error *****
< <NAK><CR><LF> Negative acknowl-edgment of a re-ceived message
Mnemonics[and parameters] ><CR>[<LF>] >
Receives messagewith "end of mes-sage"
< <ACK><CR><LF> Positive acknowl-edgment of a re-ceived message
Reception protocol
Error processing
Error recognitionprotocol
68 BG 805 195 BE / B (2004-08) TPG261.oi
→ ADC A/D converter test 85BAU Baud rate (transmission rate) 81COM Continuous mode 71CAL Calibration factor 77DCD Display control digits (display resolution) 81DGS Degas 79DIC Display control (display changeover) 82DIS Display test 84EEP EEPROM test 84EPR EPROM test 84ERR Error status 73FIL Filter time constant (measurement value filter) 76FSR Full scale range (measurement range of linear gauges) 77IOT I/O test 86LOC Keylock 83OFC Offset correction (linear gauges) 78OFD Offset display (linear gauges) 78PNR Program number (firmware version) 82PR1 Pressure measurement (measurement data) gauge 1 69PR2 Pressure measurement (measurement data) gauge 2 69PRX Pressure measurement (measurement data) gauge 1 and 2 70PUC Penning underrange control (underrange control) 79RAM RAM test 84RES Reset 74RST RS232 test 87SAV Save parameters to EEPROM 82SC1 Sensor control 1 (gauge control 1) 80SC2 Sensor control 2 (gauge control 2) 80SCT Sensor channel change (measurement channel change) 73SEN Sensors on/off 72SP1 Setpoint 1 (switching function 1) 75SP2 Setpoint 2 (switching function 2) 75SP3 Setpoint 3 (switching function 3) 75SP4 Setpoint 4 (switching function 4) 75SPS Setpoint status (switching function status) 76TID Transmitter identification (gauge identification) 72TKB Keyboard test (operator key test) 87TLC Torr lock 83UNI Pressure unit 81WDT Watchdog control 83
5.2 Mnemonics
BG 805 195 BE / B (2004-08) TPG261.oi 69
Transmit: PRx <CR>[<LF>]
Measurement value x = 1 –> Gauge 12 –> Gauge 2
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x,sx.xxxxEsxx <CR><LF>
Measurement value 1)
[in current pressure unit]
Status, x =0 –> Measurement data okay1 –> Underrange2 –> Overrange3 –> Sensor error4 –> Sensor off (IKR, PKR, IMR, PBR)5 –> No sensor (output: 5,2.0000E-2 [mbar])6 –> Identification error
1) Values always in exponential format.For logarithmic gauges, the 3rd and 4th decimalare always 0.
5.2.1 MeasurementMode
Measurement datagauge1 or 2
70 BG 805 195 BE / B (2004-08) TPG261.oi
Transmit: PRX <CR>[<LF>]Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x,sx.xxxxEsxx,y,sy.yyyyEsyy <CR><LF>
Measurement value gauge 2 1)
[in current pressure unit] Status gauge 2 Measurement value gauge 1 1)
[in current pressure unit]
Status gauge 1, x =0 –> Measurement data okay1 –> Underrange2 –> Overrange3 –> Sensor error4 –> Sensor off (IKR, PKR, IMR, PBR)5 –> No sensor (output: 5,2.0000E-2 [mbar])6 –> Identification error
1) Values always in exponential format.For logarithmic gauges, the 3rd and 4th decimalare always 0.
Measurement datagauges 1 and 2
BG 805 195 BE / B (2004-08) TPG261.oi 71
Transmit: COM [,x] <CR>[<LF>]
Mode x = 0 –> 100 ms1 –> 1 s (default)2 –> 1 min.
Receive: <ACK><CR><LF><ACK> is immediately followed by the con-tinuous output of the measurement value inthe desired interval.
Receive: x,sx.xxxxEsxx,y,sy.yyyyEsyy <CR><LF> Measurement value gauge 2 1)
[in current pressure unit] Status gauge 2 Measurement value gauge 1 1)
[in current pressure unit]
Status gauge 1, x =0 –> Measurement data okay1 –> Underrange2 –> Overrange3 –> Sensor error4 –> Sensor off (IKR, PKR, IMR, PBR)5 –> No sensor (output: 5,2.0000E-2 [mbar])6 –> Identification error
1) Values always in exponential format.For logarithmic gauges, the 3rd and 4th decimalare always 0.
Continuous output ofmeasurement values(RS232)
72 BG 805 195 BE / B (2004-08) TPG261.oi
Transmit: SEN [,x,x] <CR>[<LF>] Gauge 2, x =
0 –> No status change1 –> Turn gauge off2 –> Turn gauge on
Gauge 1
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x,x <CR><LF>
Status gauge 2, x =
0 –> Gauge cannot be turned on/off1 –> Gauge turned off2 –> Gauge turned on
Status gauge 1
Transmit: TID <CR>[<LF>]Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x,x <CR><LF>
Identification gauge 2, x =
TPR (Pirani Gauge orPirani Capacitive gauge 1))
IKR9 (Cold Cathode Gauge 10-9)IKR11 (Cold Cathode Gauge 10-11)PKR (FullRange CC Gauge)PBR (FullRange BA Gauge)IMR (Pirani / High Pressure Gauge)CMR (Linear gauge)noSEn (no SEnsor)noid (no identifier)
Identification gauge 1
1) TPR and PCR have identical identifiers.There is no distinction made in communicationand in data evaluation, since pressure rangesof these gauges are approximately the same.
Turning a gaugeon/off
Gauge identification
BG 805 195 BE / B (2004-08) TPG261.oi 73
Transmit: SCT [,x] <CR>[<LF>]
Display channel, x =0 –> Gauge 11 –> Gauge 2
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x <CR><LF>
Display channel
Transmit: ERR <CR>[<LF>]Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: xxxx <CR><LF>
xxxx =0000 –> No error1000 –> Error Controller error
(See displayon front panel)
0100 –> NO HWR No hardware0010 –> PAR Inadmissible
parameter0001 –> SYN Syntax error
The ERROR word is cancelled when read out.If the error persists, it is immediately set again.
Measurementchannel change
Error status
74 BG 805 195 BE / B (2004-08) TPG261.oi
Transmit: RES [,x] <CR>[<LF>]
x = 1 –> Cancels currently active error and returns to measurement mode
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: [x]x,[x]x,... <CR><LF>
List of all present error messages, xx =
0 –> No error 1 –> Watchdog has responded 2 –> Task fail error 3 –> EPROM error 4 –> RAM error 5 –> EEPROM error 6 –> DISPLAY error 7 –> A/D converter error 9 –> Gauge 1 error (e.g. filament
rupture, no supply)10 –> Gauge 1 identification error11 –> Gauge 2 error (e.g. filament
rupture, no supply)12 –> Gauge 2 identification error
Reset
BG 805 195 BE / B (2004-08) TPG261.oi 75
Transmit: SPx [,y,x.xxxxEsxx,x.xxxxEsxx] <CR>[<LF>] Upper threshold 1)
[in current pressure unit] (default = depending on gauge) Lower threshold 1)
[in current pressure unit] (default = depending on gauge) Switching function assignment, y =
0 –> Meas. channel 1 1 –> Meas. channel 2
1 –> Switching function 1 2 –> Switching function 2 3 –> Switching function 3 4 –> Switching function 4
1) Values can be entered in any format. Theyare internally converted into the floating pointformat.
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: y,x.xxxxEsxx,x.xxxxEsxx <CR><LF>
Upper threshold [in current pressure unit] Lower threshold [in current pressure unit]
Switching function assignment
5.2.2 Parameter Mode
5.2.2.1 SwitchingFunctionParameters
Threshold valuesetting, allocation
76 BG 805 195 BE / B (2004-08) TPG261.oi
Transmit: SPS <CR>[<LF>]Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x,x,x,x <CR><LF>
Status switching function 4 1)
Status switching function 3 1)
Status switching function 2 1)
Status switching function 1 1)
1) x = 0 –> off1 –> on
Transmit: FIL [,x,x] <CR>[<LF>] Gauge 2 x = 0 –> fast
1 –> medium(default)
2 –> slow
Gauge 1
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x,x <CR><LF>
Filter time constant gauge 2
Filter time constant gauge 1
Switching functionstatus
5.2.2.2 Gauge Parameters
Measurement valuefilter
BG 805 195 BE / B (2004-08) TPG261.oi 77
Transmit: CAL [,x.xxx,x.xxx] <CR>[<LF>] ( ) Gauge 2 log. 0.100 ... 9.990
(default = 1.000) lin. 0.500 ... 2.000
(default = 1.000)
Gauge 1
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x.xxx,x.xxx <CR><LF>
Calibration factor gauge 2
Calibration factor gauge 1
The full scale value of the measurement range(Full Scale) of linear gauges has to be definedby the user; the full scale value of logarithmicgauges is automatically recognized.
Transmit: FSR [,x,x] <CR>[<LF>] Gauge 2, x =
0 –> 0.01 mbar1 –> 0.1 mbar2 –> 1 mbar3 –> 10 mbar4 –> 100 mbar5 –> 1000 mbar (default)6 –> 2 bar7 –> 5 bar8 –> 10 bar9 –> 50 bar
Gauge 1
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x,x <CR><LF>
Measurement range gauge 2
Measurement range gauge 1
Calibration factor
Measurement range(F.S.) oflinear gauges
78 BG 805 195 BE / B (2004-08) TPG261.oi
Transmit: OFC [,x,x] <CR>[<LF>] ( ) Gauge 2, x =
0 –> off (default)1 –> on2 –> auto (offset measurement)
Gauge 1
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x,x <CR><LF>
Gauge 2
Gauge 1
Transmit: OFD [,sx.xxxxEsxx,sx.xxxxEsxx] <CR>[<LF>] Gauge 2 Offset 1)
[in current pressure unit] (default = 0.0000)
Gauge 11) Values can be entered in any format. Theyare internally converted into the floating pointformat.
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: sx.xxxxEsxx,sx.xxxxEsxx <CR><LF>
Gauge 2
Gauge 1
Offset correction(linear gauges)
Offset display(linear gauges)
BG 805 195 BE / B (2004-08) TPG261.oi 79
Transmit: PUC [,x,x] <CR>[<LF>] Gauge 2, x = 0 –> off (default)
1 –> on
Gauge 1
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x,x <CR><LF>
Gauge 2
Gauge 1
Transmit: DGS [,x,x] <CR>[<LF>] ( .) Gauge 2, x =
0 –> Degas off (default)1 –> Degas on (3 min.)
Gauge 1
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x,x <CR><LF>
Degas status gauge 2
Degas status gauge 1
Underrange control
Degas
80 BG 805 195 BE / B (2004-08) TPG261.oi
Transmit: SCx [,x,y,x.xxEsxx,y.yyEsyy] <CR>[<LF>] OFF threshold ON threshold Controlling source for gauge deactivation, x = 0 –> no control 1 –> automatic deactivation 2 –> manual deactivation (default) 3 –> external deactivation 4 –> self control Controlling source for gauge
activation, x =0 –> no control1 –> automatic activation2 –> manual activation (default)3 –> external activation4 –> hot start
Controlled gauge, x =1 –> Gauge 12 –> Gauge 2
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x,y,x.xxEsxx,y.yyEsyy <CR><LF>
OFF threshold ON threshold Controlling source for deactivating the gauge
Controlling source for activating the gauge
5.2.2.3 Gauge Control
Gauge control
BG 805 195 BE / B (2004-08) TPG261.oi 81
Transmit: UNI [,x] <CR>[<LF>]
Pressure unit, x =0 –> mbar/bar (default)1 –> Torr2 –> Pascal
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x <CR><LF>
Pressure unit
Transmit: BAU [,x] <CR>[<LF>]
Transmission rate, x =0 –> 9600 baud (default)1 –> 19200 baud2 –> 38400 baud
As soon as the new baud rate has been en-tered, the report signal is transmitted at the newtransmission rate.
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x <CR><LF>
Transmission rate
Transmit: DCD [,x] <CR>[<LF>]
Resolution, x =2 –> Display x.x (2 digits)
(default)3 –> Display x.xx (3 digits)
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x <CR><LF>
Resolution
5.2.2.4 GeneralParameters
Pressure unit
Transmission rate
Display resolution
82 BG 805 195 BE / B (2004-08) TPG261.oi
Transmit: SAV [,x] <CR>[<LF>]
x = 0 –> Save default parameters1 –> Save user parameters
Receive: <ACK><CR><LF>
Transmit: DIC [,x] <CR>[<LF>]
Measurement display behaviorwhen a Pirani gauge or a Pirani Capacitance gauge is combinedwith a linear gauge with 1000 mbar F.S., x =0 –>manual (default)1 –>automatic
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x <CR><LF>
Measurement display behavior
(For service personnel)
Transmit: PNR <CR>[<LF>]Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: 302-510-x <CR><LF>
-x = Modification index (-- = original version)
Firmware number
Save parameters toEEPROM
Display changeover
5.2.2.5 Test Parameters
Firmware version
BG 805 195 BE / B (2004-08) TPG261.oi 83
Transmit: WDT [,x] <CR>[<LF>]
x = 0 –> Manual erroracknowledgement
1 –> Automatic erroracknowledgement 1)
(default)1) If the watchdog has responded, the error isautomatically acknowledged and cancelled af-ter 2 s.
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x <CR><LF>
Watchdog control
Transmit: TLC [,x] <CR>[<LF>]
x = 0 –> off (default)1 –> on
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x <CR><LF>
Torr lock status
Transmit: LOC [,x] <CR>[<LF>]
x = 0 –> off (default)1 –> on
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x <CR><LF>
Keylock status
Watchdog control
Torr lock
Keylock
84 BG 805 195 BE / B (2004-08) TPG261.oi
Transmit: RAM <CR>[<LF>]Receive: <ACK><CR><LF>Transmit: <ENQ> Starts the test (duration <1 s)
Receive: xxxx <CR><LF>
ERROR word
Transmit: EPR <CR>[<LF>]Receive: <ACK><CR><LF>Transmit: <ENQ> Starts the test (duration ≈5 s)
Receive: xxxx,yyyy <CR><LF> Check sum (hex)
ERROR word
Transmit: EEP <CR>[<LF>]Receive: <ACK><CR><LF>Transmit: <ENQ> Starts the test (duration <1 s)
Do not keep repeating the test (EEPROM life).
Receive: xxxx <CR><LF>
ERROR word
Transmit: DIS [,x] <CR>[<LF>]
x = 0 –> Stops the test – displayaccording to currentoperating mode (default)
1 –> Starts the test –all LEDs on
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x <CR><LF>
Display test status
RAM test
EPROM test
EEPROM test
Display test
BG 805 195 BE / B (2004-08) TPG261.oi 85
Transmit: ADC <CR>[<LF>]Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: [x]x.xxxx,[x]x.xxxx,x.xxxx,x.xxxx <CR><LF>
ADC channel 4 identification Gauge 2 [0.0000 ... 5.0000 V] ADC channel 3 Gauge 1 identification [0.0000 ... 5.0000 V] ADC channel 2 Measurement signal
gauge 2[0.0000 ... 11.0000 V]
ADC channel 1Measurement signal gauge 1[0.0000 ... 11.0000 V]
ADC test
86 BG 805 195 BE / B (2004-08) TPG261.oi
Caution
Caution: The relays switch irrespective of thepressure.Starting a test program may cause unwantedeffects in connected control systems.Disconnect all sensor cables and controlsystem lines to ensure that no control com-mands or messages are triggered by mistake.
Transmit: IOT [,x,yy] <CR>[<LF>] Relay status (in hex format), yy =
00 –> All relays deactivated01 –> Switching function relay 1
activated02 –> Switching function relay 2
activated04 –> Switching function relay 3
activated08 –> Switching function relay 4
activated10 –> Gauge relay CH1 activated20 –> Gauge relay CH2 activated40 –> Error relay activated7F –> All relays activated
x = 0 –> Test stopped1 –> Test runs
Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: x,yy <CR><LF>
Relay status
I/O test status
I/O test
BG 805 195 BE / B (2004-08) TPG261.oi 87
Transmit: TKB <CR>[<LF>]Receive: <ACK><CR><LF>Transmit: <ENQ>Receive: xxxx <CR><LF>
Key 4 x = 0 –> Not pushed1 –> Pushed
Key 3
Key 2
Key 1
Transmit: RST <CR>[<LF>]Receive: <ACK><CR><LF>Transmit: <ENQ> Starts the test (repeats each
character, test is interruptedwith <CTRL> C)
Operator key test
RS232 test
88 BG 805 195 BE / B (2004-08) TPG261.oi
"Transmit (T)" and "Receive (R)" are related to Host.
S: TID <CR> [<LF>]E: <ACK> <CR> <LF>S: <ENQ>E: TPR,CMR <CR> <LF>
Request for gauge identificationPositive acknowledgementRequest for data transmissionGauge identifications
S: SEN <CR> [<LF>]E: <ACK> <CR> <LF>S: <ENQ>E: 0,0 <CR> <LF>
Request for gauge statusesPositive acknowledgementRequest for data transmissionGauge statuses
S: SP1 <CR> [<LF>]
E: <ACK> <CR> <LF>S: <ENQ>E: 0,1.0000E-09,9.0000E-07 <CR> <LF>
Request for parameters ofswitching function 1 (setpoint 1)Positive acknowledgementRequest for data transmissionThresholds
S: SP1,1,6.80E-3,9.80E-3 <CR> [<LF>]
E: <ACK> <CR> <LF>
Modification of parameters ofswitching function 1 (setpoint 1)Positive acknowledgement
S: FOL,1,2 <CR> [<LF>]
E: <NAK> <CR> <LF>S: <ENQ>E: 0001 <CR> <LF>S: FIL,1,2 <CR> [<LF>]E: <ACK> <CR> <LF>S: <ENQ>E: 1,2 <CR> <LF>
Modification of filter time constant(syntax error)Negative acknowledgementRequest for data transmissionERROR wordModification of filter time constantPositive acknowledgementRequest for data transmissionFilter time constants
5.2.3 Example
BG 805 195 BE / B (2004-08) TPG261.oi 89
6 Maintenance
The product requires no maintenance.
For cleaning the outside of the TPG 261, a slightly moistcloth will usually do. Do not use any aggressive orscouring cleaning agents.
DANGER
Caution: mains voltageContact with live parts is extremely hazardouswhen liquids penetrate into the unit.Make sure no liquids penetrate into theequipment.
Cleaning the TPG 261
90 BG 805 195 BE / B (2004-08) TPG261.oi
7 Troubleshooting
and the error relay opens (→ 21).
Possible cause and remedy/acknowledgement
Interruption or instability in sensor lineor connector (Sensor error).
Acknowledge with the . keyIf the problem persists, or
is displayed.
Possible cause and remedy/acknowledgement
The TPG 261 has been turned on toofast after power off.
Acknowledge with the key.If the watchdog is set to ,the TPG 261 acknowledges themessage automatically after 2 s(→ 57).
The watchdog has tripped because ofa severe electric disturbance or an op-erating system error.
Acknowledge with the key.If the watchdog is set to ,the TPG 261 acknowledges themessage automatically after 2 s(→ 57).
Possible cause and remedy/acknowledgement
Main memory (RAM) error.
Acknowledge with the key.
Possible cause and remedy/acknowledgement
Program memory (EPROM) error.
Acknowledge with the key.
Signalization of errors
Error messages
BG 805 195 BE / B (2004-08) TPG261.oi 91
Possible cause and remedy/acknowledgement
Parameter memory (EEPROM) error.
Acknowledge with the key.
Possible cause and remedy/acknowledgement
Display driver error.
Acknowledge with the key.
Possible cause and remedy/acknowledgement
A/D converter error.
Acknowledge with the key.
Possible cause and remedy/acknowledgement
Operating system (Task Fail) error.
Acknowledge with the key.
If the problem persists after the message has beenacknowledged for several times and/or the gaugehas been exchanged, please contact you localPfeiffer Vacuum service center.
8 Repair
Return defective products to your nearestPfeiffer Vacuum service center for repair.Pfeiffer Vacuum assumes no liability and the warrantybecomes null and void if repair work is carried out by theend-user or third parties.
Technical support
92 BG 805 195 BE / B (2004-08) TPG261.oi
9 Storage
Caution
Caution: electronic componentInappropriate storage (static electricity, hu-midity etc.) can damage electronic compo-nents.Store the product in an antistatic bag or con-tainer. Observe the corresponding specifica-tions in the technical data (→ 9).
10 Disposal
N
WARNING
Caution: substances detrimental to the envi-ronmentProducts or parts thereof (mechanical andelectric components, operating fluids etc.)can be detrimental to the environment.Dispose of such substances in accordancewith the relevant local regulations.
After disassembling the product, separate its compo-nents according to the following criteria:
Such components must be separated according to theirmaterials and recycled.
Such components must be separated according to theirmaterials and recycled.
Separating thecomponents
Non-electroniccomponents
Electroniccomponents
BG 805 195 BE / B (2004-08) TPG261.oi 93
Appendix
kg lb slug ozkg 1 2.205 68.522×10-3 35.274lb 0.454 1 31.081×10-3 16slug 14.594 32.174 1 514.785oz 28.349×10-3 62.5×10-3 1.943×10-3 1
N/m2, Pa bar mbar Torr atN/m2, Pa 1 10×10-6 10×10-3 7.5×10-3 9.869×10-6
bar 100×103 1 103 750.062 0.987mbar 100 10-3 1 750.062×10-3 0.987×10-3
Torr 133.322 1.333×10-3 1.333 1 1.316×10-3
at 101.325×103 1.013 1.013×103 760 1
mbar Pascal Torr mmWs psimbar 1 100 750.062×10-3 10.2 14.504×10-3
Pascal 10×10-3 1 7.5×10-3 0.102 0.145×10-3
Torr 1.333 133.322 1 13.595 19.337×10-3
mmWs 9.81×10-2 9.81 7.356×10-2 1 1.422×10-3
psi 68.948 6.895×103 51.715 703 1
mm m inch ftmm 1 10-3 39.37×10-3 3.281×10-3
m 103 1 39.37 3.281inch 25.4 25.4×10-3 1 8.333×10-2
ft 304.8 0.305 12 1
Kelvin Celsius FahrenheitKelvin 1 °C+273.15 (°F+459.67)×5/9Celsius K-273.15 1 5/9×°F-17.778Fahrenheit 9/5×K-459.67 9/5×(°C+17.778) 1
A: Conversion Tables
Weights
Pressures
Pressure units used inthe vacuum technology
Linear measures
Temperature
94 BG 805 195 BE / B (2004-08) TPG261.oi
The following values are activated when the default set-tings are loaded (→ 54):
1000 mbar
1.00 (log)1.000 (lin)
normal
off0×10-2 mbar
1×10-11 mbar
Default
off
mbar
9600
2 Digit
User
off
off
Auto
Hand
9×10-11 mbar
B: Default Settings
BG 805 195 BE / B (2004-08) TPG261.oi 95
If your TPG 261 firmware needs updating, e.g. forimplementing a new gauge type, please contactyour local Pfeiffer Vacuum service center.
Most of the settings you may have defined in the Pa-rameter and Test mode will not be affected by a firm-ware update. To be sure, note your parameter settingsbefore upgrading the firmware (→ 94).
Turn the TPG 261 off.
Connect the TPG 261 with the serial COM1(COM2) interface of your PC via a 9-pole D-Subextension cable (→ 23) (the firmware of theTPG 261 cannot be loaded from a Mac).
With a pin (ø<2 mm), depress the switch on thetop of the unit, under the housing, and turn theTPG 261 on.
After power on, the display remains dark.
C: Firmware Update
User parameters
Preparing the TPG 261for a program transfer
96 BG 805 195 BE / B (2004-08) TPG261.oi
In the following instructions, the index is used insteadof the actual index.
Unpack the self extracting file.
If you have not connected the TPG 261 to theCOM1 interface:
• Open the batch file …
• … edit the interface …
• … and save the new setting.
Start batch file .
The new firmware is transmitted to the TPG 261.
Program transfer
BG 805 195 BE / B (2004-08) TPG261.oi 97
If the program transfer was successful, quit the Updatemode by turning the TPG 261 off.
Wait at least 10 s before turning the TPG 261on again in order for it to correctly initialize it-self.
The TPG 261 is now ready for operation. To besure, check that the current parameter settings areidentical with the previously defined settings(→ 94).
Starting the TPG 261with the updated firm-ware
98 BG 805 195 BE / B (2004-08) TPG261.oi
[1] www.pfeiffer-vacuum.deInstruction SheetCompact Pirani Gauge TPR 261BG 805 105 BEPfeiffer Vacuum GmbH, D–35614 Asslar,Deutschland
[2] www.pfeiffer-vacuum.deOperating InstructionsCompact Pirani Gauge TPR 265BG 805 177 BEPfeiffer Vacuum GmbH, D–35614 Asslar,Deutschland
[3] www.pfeiffer-vacuum.deOperating InstructionsPirani-Messröhre TPR 280BG 805 178 BEPfeiffer Vacuum GmbH, D–35614 Asslar,Deutschland
[4] www.pfeiffer-vacuum.deOperating InstructionsPirani-Messröhre TPR 281BG 5179 BEPfeiffer Vacuum GmbH, D–35614 Asslar,Deutschland
[5] www.pfeiffer-vacuum.deOperating InstructionsCompact Pirani Capacitance Gauge PCR 260BG 805 180 BEPfeiffer Vacuum GmbH, D–35614 Asslar,Deutschland
[6] www.pfeiffer-vacuum.deInstruction SheetCompact Cold Cathode Gauge IKR 251BG 805 110 BNPfeiffer Vacuum GmbH, D–35614 Asslar,Deutschland
[7] www.pfeiffer-vacuum.deInstruction SheetCompact Cold Cathode Gauge IKR 261BG 805 113 BNPfeiffer Vacuum GmbH, D–35614 Asslar,Deutschland
D: Literature
BG 805 195 BE / B (2004-08) TPG261.oi 99
[8] www.pfeiffer-vacuum.deInstruction SheetCompact Cold Cathode Gauge IKR 270BG 805 115 BE / APfeiffer Vacuum GmbH, D–35614 Asslar,Deutschland
[9] www.pfeiffer-vacuum.deInstruction SheetCompact FullRange™ Gauge PKR 251BG 805 119 BNPfeiffer Vacuum GmbH, D–35614 Asslar,Deutschland
[10] www.pfeiffer-vacuum.deInstruction SheetCompact FullRange™ Gauge PKR 261BG 805 122 BNPfeiffer Vacuum GmbH, D–35614 Asslar,Deutschland
[11] www.pfeiffer-vacuum.deInstruction SheetCompact Process Ion Gauge IMR 265BG 805 132 BEPfeiffer Vacuum GmbH, D–35614 Asslar,Deutschland
[12] www.pfeiffer-vacuum.deInstruction SheetCompact FullRange™ BA Gauge PBR 260BG 805 131 BEPfeiffer Vacuum GmbH, D–35614 Asslar,Deutschland
[13] www.pfeiffer-vacuum.deInstruction SheetCompact Capacitance GaugeCMR 261 … CMR275BG 805 133 BEPfeiffer Vacuum GmbH, D–35614 Asslar,Deutschland
[14] www.pfeiffer-vacuum.deInstruction SheetCompact Piezo Gauge APR 250 … APR 267BG 805 127 BNPfeiffer Vacuum GmbH, D–35614 Asslar,Deutschland
100 BG 805 195 BE / B (2004-08) TPG261.oi
– A –A/D converter test 61
– B –Baud rate 53
– C –Calibration factor 40Cleaning 89Communication 64
interface 64Conformity 102Connectors
control 21mains power 19relay 22RS232 23sensor 20
Contact positionscontrol 21relay 22
Contents 4control connector 21Conversion 93
– D –Default settings 54; 94Degas 45Display
resolution 54test 60
Disposal 92
– E –EEPROM test 60EPROM test 59Error messages 90Example 88
– F –Factory settings 54; 94Filter 38Firmware
update 95version 2; 57
– G –Gauge connector 20Gauge control 46
gauge activation 48gauge deactivation 49OFF threshold 50
Gauge identification 30Gauge parameters 37
calibration factor 40Degas 45measurement range 41measurement value filter 38offset 42underrange control 43
General parameters 51default settings 54display resolution 54measurement units 53transmission rate 53
– I –I/O test 62Identification of gauges 30Intended Use 3Interface
connector 23test 63transmission rate 53
– K –Keylock 58
– L –Liability 8Literature 98
– M –Mains power connector 19Maintenance 89Measurement mode 27; 69
gauge identification 30status messages 28turning the gauge on/off 28
Measurement range 41Measurement units 53
conversion 93Measurement value filter 38Mnemonics 68
E: Index
BG 805 195 BE / B (2004-08) TPG261.oi 101
– O –OFF threshold 50Offset 42Operating modes
Measurement mode 27overview 26Parameter mode 31Program transfer mode 95
Operationpower off 25power on 25
– P –Parameter mode 31; 75
Gauge control 46Gauge parameters 37General parameters 51Switching functionparameters 33Test parameters 55
Pin assignmentcontrol 21relay 22RS232 23
Power connector 19Power off 25Power on 25Pressure units 53
conversion 93Program
update 95version 2; 57
– R –RAM test 59relay connector 22Repair 91RS232
connector 23RS232C
test 63
– S –Safety 6
Scope of delivery 3sensor connector 20Serial interface
connector 23Status messages 28Storage 92Switching functionparameters 33Switching functions 22; 35; 36Symbols 6
– T –Test parameters 55Test program 55
A/D converter test 61display test 60EEPROM test 60EPROM test 59firmware version 57I/O test 62keylock 58RAM test 59RS232C test 63Torr lock 58watchdog 58
Thresholds 35; 36Torr lock 58Transmission rate 53Troubleshooting 90
– U –Underrange control 43Units
conversion 93Update 95
– V –Validity 2
– W –Warranty 8Watchdog 58
102 BG 805 195 BE / B (2004-08) TPG261.oi
Declaration of Conformity
We, Pfeiffer Vacuum, hereby declare that the equipmentmentioned below complies with the provisions of the Di-rective relating to electrical equipment designed for usewithin certain voltage limits 73/23/EEC and the Directiverelating to electromagnetic compatibility 89/336/EEC.
SingleGauge™Single-Channel Measurement andControl Unit for Compact Gauges
TPG 261
PTG28030
Harmonized and international/national standards andspecifications:• EN 61010-1 (Safety requirements for electrical equipment
for measurement, control and laboratory use)
• EN 50081-1 (Electromagnetic compatibility generic emissionstandard)
• EN 50082-2 (Electromagnetic compatibility generic immunitystandard)
Pfeiffer Vacuum GmbH, Asslar9 May 2001
Wolfgang DondorfManaging director
Product
Part number
Standards
Signature
Berliner Strasse 43D–35614 AsslarDeutschlandTel +49 (0) 6441 802-0Fax +49 (0) 6441 802-202
Original: German BG 805 195 BD / B (2004-08) [email protected]
bg805195be/ b www.pfeiffer-vacuum.de