Easy-To-UseCable AndAntenna Tester
-
7/29/2019 Site Analyzer - Brochure 1
2/8
The BestPortableCable And Antenna tester For
Wireless Professionals
The BestPortableCable And Antenna tester For
WirelessProfessionals
Site AnalyzerEasy-to-use cable and antenna tester
World-wide applications include Cellular and PCS/DCS systemswith AMPS, CDMA, GSM or TDMA modulation schemes.Other applications include 3G, Paging and Trunking Currentfrequency range is 806 to 2300 MHz
Easy operation for first-time, occasionalor experienced users
Accurate and repeatable measurements Immunity to on-channel interference (+13 dBm)
for testing at co-located antenna sites
High-resolution color display Fast sweep rate On-screen comparison of live sweep and recalled trace Unlimited trace overlays per report to compare
antennas and track performance over time Power meter option compatible with Bird power sensors
Identify Small ProblemsBefore They Grow Into Big HeadachesThe Site Analyzers advanced design and high resolution color display
help you detect minor problems before they become major headaches.Birds instrument easily uncovers faults that elude less sophisticated testers.
And the Site Analyzers high directivity and low source match ensure accurateand repeatable Match and Fault Location measurements.
Locate long range problems with 238 display points. Pinpoint small problems with 60 dB dynamic range. High resolution marker reports VSWR with the precision of expensive laboratory equipment. Site Analyzer measurements are interchangeable with your existing measurement data. Perform cable insertion loss measurements Include optional power measurement capability
Superior Signal Immunity
Lets You Test When Its ConvenientHigh ambient RF levels can limit the usefulnessof other cable and antenna test instruments.Birds advanced Site Analyzer rejectson-channel interfering signals to +13 dBm,so you can test antennas located in activesites. Work when its convenient not justwhen a site can be powered-down.
-
7/29/2019 Site Analyzer - Brochure 1
3/8
PortableAnalytical power
Helps You DoThe Job Right
PortableAnalytical power
Helps You Do The Job Right
Display forward and reflected poweras well as VSWR and return loss
Compatible with Model 5010 Digital Power Sensor
Small and lightweight sensor Multi-carrier capable, may be placed at
output of transmit combineror linear power amplifier
Accuracy of 5% of readingwith 40:1 Dymanic RangeExample, 50W element measuresfrom 1.25 to 50W
On-screen Data Comparison No PC RequiredSelf-contained analytical capabilities let you precisely compare two traceson-screen without using a PC. The Site Analyzer provides a lot more thanreliable measurements of Fault Location, Return Loss and VSWR.
The bright, color screen highlights key information to help youquickly pot problems. State-of-the-art transflective LCD technologyprovides crisp visibility in everything from darkened sheltersto direct sunlight!
Precise markers report VSWR to 0.01 dB. An automatic deltamarker compares two traces to reveal any degradation in antenna
system performance. A Pass-Fail indicator facilitates quick Go/No Go Testing. Digital signal processing provides trace updates in only 2 seconds. Stores 60 sets of measurement data with a time/date stamp. Built-in parallel printer port for direct printing of professional
looking, instant reports. Built-in drivers support popular HP ink jet printers. Serial interface supports data transfer to a PC for additional analysis
with our Windows 95/98/NT compatible software. Cable loss mode Power measurement with 5010 Sensor
-
7/29/2019 Site Analyzer - Brochure 1
4/8
Fast, EasyOperation
Increases YouProfitability
Fast, EasyOperation
Increases Your
ProfitabilityBird designed the Site Analyzer to be exceptionally easy-to-operate. Extensive user beta tests led to numerous refinements.The final product is a portable cable and antenna tester thatsurpasses all others in testing capability, operating speed andits ability to be mastered by inexperienced technicians.
1
2
3
3
4
6
7
5
1 High-impact housing is lightweight, rugged andergonomically sculpted for comfortable hand-held use.
2 Bright, high resolution color screen accentuatesimportant findings and clearly organizes operatingfunctions and test results.
3 Intuitive soft key, menu operationlets you focus on testing.
4 Four dedicated keys for commonly usedfunctions accelerate testing.
5 Up to 5 calibration profiles are stored in
non-volatile memory.
6 Pop-up menus contain over 70 cable types and30 frequency band presets. Quickly select testparameters without set-up errors.
7 Measurement data is stored in non-volatile memory. Data labeling allowsdescriptive naming of measurement data. The automatic time-date stampis another convenient way of organizing measurement results.
-
7/29/2019 Site Analyzer - Brochure 1
5/8
AdvancedBattery
TechnologyFor Reliable Portable Op
The new Site AnalyzerTM brings portable operation to unprecedented
levels with an advanced power system.A memory-free Li-Ion batteryreliably provides 3 hours minimum operating time per charge. Nospecial conditioning or discharge cycling is required. Longeroperation is available using an optional external battery pack.
Advanced Li-ion battery operates 3+ hours on a single charge. Li-Ion has no memory effects like old fashioned Nicad
batteries; no special charge conditioning is required. Battery power pack can be repaired in the field while your
data remains safe in nonvolatile memory. Automatic power-down conserves battery life.
Charge activity and battery condition are easilyviewed on the front panel indicator. Can also be powered with any 9-16 Vdc power supply.
An AC Power Supply and Automotive Adapter are included.
Optional SA-BATPAK external battery pack is available for usersdesiring longer operating time than the 3 hours provided by theSiteAnalyzers internal power supply.
Powerful Analysis Software
Creates Professional ReportsThe Site Analyzer features built-in analytical and reportingfunctions, but you can also download measurement data to a PCfor additional analysis. Birds user-friendly MS Windows 95/98/NTcompatible software does everything from analyzing an unlimitednumber of traces to using data generated by other cable andantenna testers.
Compatibility with existing data generated by the Anritsu SiteMaster, Bird Site Analyzer and Bird AT-Series Testers.
Familiar Windows 95/98/NT interface simplifies dataanalysis and report generation.
Operates with Windows 3.1/95/98 equipped PCs orWindows NT Workstations.
Supports long file names for easy data identification. Build historical records with an unlimited number of traces
in one document.
Intelligent drag-and-drop automatically converts tracesto a common scale for precise and reliable comparisons.
Automatic cursor calibration maintains accurate readoutsof trace data even if the x-axis changes.
Windows is a registered trademark of Microsoft Corporation.
AdvancedBattery
TechnologyFor Reliable Portable Operation
-
7/29/2019 Site Analyzer - Brochure 1
6/8
on
Precision Calibration Combos
Three precision standards combinedin one convenient component.
Type N and 7/16 DIN available.
These all-in-one, T-design
devices contain a precision load,open, and short for calibration of the Site Analyzer. A choice ofconnectors enables these kits to be used at the Site Analyzers testport, or the end of a test cable.
Part No. Description
CAL-MN-A N-type male connectors
CAL-FN-A N-type female connectors
CAL-ME-A 7/16 DIN male connectors
CAL-FE-A 7/16 DIN female connectors
Test Port Extension Cables
Phase-stable for reliable,consistent results.
Armored shield holdsup to field use.
TC-Series test cables are available in a variety of lengths and
terminations. The male N-type termination connects to the SiteAnalyzer test port. The other connector is available as male orfemale N type or 7/16 DIN.
Part No. Length, Connectors
TC-MNMN-1.5 1.5 meters.Male N + Male NTC-MNMN-3.0 3 meters. Male N + Male N
TC-MNMN-5.0 5 meters.Male N + Male N
TC-MNMN-1.5 1.5 meters.Male N + Female N
TC-MNMN-3.0 3 meters.Male N + Female N
TC-MNMN-5.0 5 meters.Male N + Female N
TC-MNMN-1.5 1.5 meters. Male N + Female 7/16 DIN
TC-MNMN-3.0 3 meters.Male N + Female 7/16 DIN
TC-MNMN-5.0 5 meters.Male N + Female 7/16 DIN
Model 5010
Digital Power Sensor and DPM Elements
Display forward and reflected power as well
as VSWR and return loss Small and lightweighted sensor
Multi-carrier capable, may be placed at
output of transmit combiner or linear
power amplifier
Accuracy of 5% of reading with 40:1 Dymanic Range
Example, 50W element measures from 1.25 to 50W
Connector Adapters
These adapters permit you to mate
N-type and 7/16 DIN male and femaleconnectors. They are an ideal accessory for use withthe TC Series armored, phase-stable test cables.
Compensated transition ensures repeatable results. Type N to 7/16 DIN male and female.
Part No. Description
PA-MNME N-type male to 7/16 DIN male
PA-FNME N-type female to 7/16 DIN male
PA-MNFE N-type male to 7/16 DIN female
PA-FNFE N-type female to 7/16 DIN female
External Battery Pack
Up to 2 hours additional operation. Reliable lead-acid technology.
The SA-BATPAK External Battery Pack delivers up to two hoursof additional operating time. A case, shoulder strap, belt clip,and charge adapter are included.
Transit Case
The Model 7002B870 Transit Case affords maximum protection for
the Site Analyzer and accessory items during field use or shipmentof the unit. Durable hardshell, polyethylene molded construction withmetal frame and latches.
Optional Site Analyzer
AccessoriesFor Assembling Custom Test Packages
-
7/29/2019 Site Analyzer - Brochure 1
7/8
Preliminary specifications. Bird reserves the right to change features and specification without notice or obligation.Meter,sensor, and plug-in elements priced separately.
* Power and frequency range based on selected plug-in elements.Select FWD and RFL elements with a 10:1 power ratio.
Example: Select 50 W FWD element and 5 W RFL element.
SPECIFICATIONS
SITE ANALYZERAND
STANDARD ACCESSORIES
FREQUENCY CHARACTERISTICSMODEL SA-2000A
Frequency Range: 806 - 2300 MHz
Trace Resolution: 238 data points
MEASUREMENTCHARACTERISTICS
Return Loss: 0 to -60 dBTest Port: N-type female connector
Impedance: 50
Speed: 1 multi-frequency scan/2 secondsImmunity to Interfering Signals: Rejects on-channel signals up to +13 dBm.
Maximum Input Signal: +22 dBm
PERIPHERAL PORTSData transfer: 9-pin RS-232 (DB9), compatible with PC serial port.
Selectable baud, parity, and handshake.
Printer: 25-pin (DB25) parallel. Built-in drivers for popularHP-type ink jet printers.
POWERInternal: Rechargeable (fast charge) Li-Ion batteries.
3 hour minimum operating time.Auto shut-off conserves battery life.
External DC: 9 to 16 Vdc, fused
External AC: 100 to 240 Vac, 50-60 Hz
ENVIRONMENTALOperating Temperature: -10 to 50 C (14 to 122 F)
Storage Temperature: -40 to 80 C (-40 to 176 F)Humidity: 95% 5% max., (non-condensing)
Altitude: Up to 15,000 feet (4572 m)
FORM FACTORDimensions: 10-1/2" x 8-1/2" x 3-1/4" (267 x 216 x 83 mm)
Weight: 4-1/2 lb (2 kg)
STANDARD ACCESSORIESThe Site Analyzer includes Carrying Case, Instruction Manual,Serial Cable, PC Tool Software for Windows, AC Power Supplyand Automotive Power Adapter.
-
7/29/2019 Site Analyzer - Brochure 1
8/8
30303 Aurora Road, Cleveland, OH 44139-2794
Tel: 440-248-1200
Fax:440-248-5426
Email: [email protected]
Website: http://www.bird-electronic.com
Electronic CorporationA Member of Bird Technologies Group
2000 Bird Electronic Cor871-SAT0