1000W Pure Sine Wave Inverters SK
FEATURES
True sine wave output (THD < 3%)
Power ON-OFF remote control
Input & output fully isolation
Load control cooling fan
Advanced microprocessor
Output frequency 50/60 Hz switch selectable
Low power saving mode to conserve energy
Input polarity reverse / under voltage / over voltage protections
Output short circuit / overload / over temperature protections
Tri-color indicators display input, output level & failure status
e-13 / CE / FCC approved
North America (GFCI)NEMA 5-15R Schuko
Australia
New Zealand United KingdomUniversal
OUTPUT
INPUT
AC VOLTAGERATED POWER
SURGE POWER
WAVEFORM
FREQUENCY
AC REGULATION
STANDARD RECEPTACLES
LED INDICATOR
NO LOAD CURRENT DRAW
VOLTAGE RAN GE
EFFICIENCY(Typ.)
FUSE
REMOTE CONTROL UNIT
100 / 110 / 120VAC1000W
2000W
True sine wave (THD < 3%)
50 / 60 Hz selectable by DIP switch
NEMA5-15R / GFCI
Input voltage level, output load level and fault status
CR6 / CR8 optional
SK1000-112 SK1000-124 SK1000-148 SK1000-212
220 / 230 / 240 VAC
Schuko / UK / Australia / Universal
0.38A
12VDC
1.20A 0.60A
10.5~15.0VDC
POWER FACTORALLOWED COS -90 O ~ COS +90
O
MODEL No. SK1000-224 SK1000-248
1.43A 0.75A 0.28A
DC VOLTAGE
STAND-BY CURRENT DRAW 0.25A 0.15A 0.09A 0.08A0.15A0.25A
24VDC 48VDC 12VDC 24VDC 48VDC
21.0~30.0VDC 4 2. 0~ 60 VD C 1 0. 5~ 15 .0 VD C 2 1. 0~ 30 .0 VD C 4 2. 0~ 60 VD C
92.0%89.0% 93.0% 91.0% 94.0%93.0%
20A x 240A x 4 20A x 4
PROTECTION
ENVIRONMENT
SAFETY& EMC
OTHERS
BAT. LOW SHUTDO WN
OVER LOAD
OVER VO LTAGE
OVER TEMPERATURE
OUTPUT SHORT
BAT. POLARI TY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP. HUMIDITY
SAFETYSTANDARDS
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
EMS IMMUNITY
LVD
e-MARK
DIMENSION
PACKING
COOLING
APPLICATION
10.5VDC
Shut off output voltage, re-power on to recover
15.3VDC
Shut off output voltage, recovers automatically after temperature goes down
Shut off output voltage, re-power on to recover
By fuse open
0 ~ +40 C
20% ~ 90% RH non-condensing
- 30 C ~ + 70 / C - 2 2 F ~ + 1 58 F / 1 0 ~9 5 %
Meet UL458
I/P ~ O/P: 100M Ohms / 500VDC
Compliance to FCC classA
-----
-----
-----
383 x 182 x 88mm (L x W x H)
4.0kgs; 4sets / 20kgs / CARTON
Home and Office applianc es, Power tools and Portable equi pments, Vehicle, Yacht and Solar power systems …etc.
30.6VDC
-----
Compliance to EN55022 class A
Compliance to EN61000-3 -2, 3
Compliance to EN60950-1
Compliance to e-13 * 72/245/EEC, 95/54/EC
BAT. LOWALA RM 11VDC 22VDC 44VDC 11VDC 22VDC 44VDC
21.0VDC 42.0VDC 10.5VDC 21.0VDC 42.0VDC
Loading controlled cooling fan
61.2VDC 15.3VDC 30.6VDC 61.2VDC
%3
20A x 240A x 4 20A x 4