sliding gate operator pull t24, -t24speed81.223.229.147/part/e/e_pull-t24-t24speed_290017.pdf ·...

8
Fields of application: For all cantilever and rail driven sliding gates. PULL T24, -T24speed features Programmable control panel accessible from exterior with illuminated display in english Direct connection of 8,2 kOhm contact barriers (safety sensing edges (2-channels) Adjustable soft stop (no loss of force even with reduced revolution speed) Three operating modes (impulse, automatic and dead man) Adjustable partial opening Built in control board in separate housing Safety system ARS (automatic reversal system) Self locking worm gear Emergency release, lockable with profile half cylinder (3 keys included) - changeable, thus incorporation into an existing house key system is possible. Backup battery can be integrated (optional) 24V motor Drive unit (gearbox unit) made of steel and runs in an oil bath Worm gear and worm wheel made of tempered steel Permanently selflearning force Current consumption in standby is minimal thanks to switch-mode power supply Technical information / Planning document Sliding gate operator PULL T24, -T24speed Tousek Ges.m.b.H. Austria A-1230 Vienna Zetschegasse 1 Tel. +43/ 1/ 667 36 01 Fax +43/ 1/ 667 89 23 [email protected] Tousek GmbH Germany D-83395 Freilassing Traunsteiner Straße 12 Tel. +49/ 8654/ 77 66-0 Fax +49/ 8654/ 57 196 [email protected] Tousek Benelux NV BE-3930 Hamont - Achel Buitenheide 2A/ 1 Tel. +32/ 11/ 91 61 60 Fax +32/ 11/ 96 87 05 [email protected] Tousek Sp. z o.o. Poland PL 43-190 Mikołów (k/Katowic) Gliwicka 67 Tel. +48/ 32/ 738 53 65 Fax +48/ 32/ 738 53 66 [email protected] Tousek s.r.o. Czech Republic CZ-130 00 Praha 3 Jagellonská 9 Tel. +420/ 2/ 2209 0980 Fax +420/ 2/ 2209 0989 [email protected] Safety Sensor b y T Ü V - S ü d I N I T I A L T E S T UNDER EN 13241-1*)

Upload: tranquynh

Post on 21-Jun-2018

289 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Sliding gate operator PULL T24, -T24speed81.223.229.147/part/E/E_PULL-T24-T24speed_290017.pdf · PULL T24, -T24speed features ... (KE) Connector for battery 24Vd.c. (optional) (KM)

Fields of application:

• For all cantilever and rail driven sliding gates.

PULL T24, -T24speed features

• Programmable control panel accessible from exterior with illuminated display in english • Direct connection of 8,2 kOhm contact barriers (safety sensing edges (2-channels) • Adjustable soft stop (no loss of force even with reduced revolution speed) • Three operating modes (impulse, automatic and dead man) • Adjustable partial opening• Built in control board in separate housing• Safety system ARS (automatic reversal system)• Self locking worm gear• Emergencyrelease,lockablewithprofilehalfcylinder(3keysincluded)-changeable,thus

incorporation into an existing house key system is possible.• Backup battery can be integrated (optional) • 24V motor • Drive unit (gearbox unit) made of steel and runs in an oil bath • Worm gear and worm wheel made of tempered steel• Permanentlyselflearningforce• Current consumption in standby is minimal thanks to switch-mode power supply

Technical information / Planning document

Sliding gate operator PULL T24, -T24speed

tousek PRODUCTS

• slidinggateoperators

• cantileversystems

• swinggateoperators

• garagedooroperators

• foldingdooroperators

• trafficbarriers

• carparkmanagementsystem

• windowoperators

• domelightoperators

• slidingdooroperators

• electroniccontrols

• radioremotecontrols

• keyoperatedswitches

• accesscontrol

• safetydevices

• accessories

your service partner:

Tousek Ges.m.b.H.AustriaA-1230ViennaZetschegasse1

Tel.+43/1/6673601Fax+43/1/6678923

[email protected]

Tousek GmbHGermanyD-83395Freilassing

TraunsteinerStraße12Tel.+49/8654/7766-0Fax+49/8654/57196

[email protected]

Tousek BeneluxNVBE-3930Hamont-Achel

Buitenheide2A/1Tel.+32/11/916160Fax+32/11/968705

[email protected]

Tousek Sp. z o.o.PolandPL43-190Mikołów(k/Katowic)

Gliwicka67Tel.+48/32/7385365Fax+48/32/7385366

[email protected]

Tousek s.r.o.CzechRepublicCZ-13000Praha3

Jagellonská9Tel.+420/2/22090980Fax+420/2/22090989

[email protected]

Wereservetherighttochangedimensionsand/ortechnicalspecificationswith-outpriornotice.Claimsresultingfrommisprintsorerrorscannotbeaccepted.

Safety Sensor

by TÜV-Süd

INITIAL TEST

UNDER

EN 13241-1*)

Page 2: Sliding gate operator PULL T24, -T24speed81.223.229.147/part/E/E_PULL-T24-T24speed_290017.pdf · PULL T24, -T24speed features ... (KE) Connector for battery 24Vd.c. (optional) (KM)

- 2 - tousek/E_PULL-T24-T24speed_29001705/23.04.2018

2

5a

11

3

1

4a4

5

66a

6b

9

10

8

7

(5) Control board (Display and control buttons)

(5a) Removable display cover(6) Control housing(6a) Cover for optional, pluggable

radio module(6b) Indication for opt. additional module(7) Sensor(8) Motor condenser(9) Motor-/gear unit(10) Threaded hole for attachment of

motor cover(11) Motor cover

(1) Lockable emergency release (PHZ)(2) Gear wheel(3) Cablefittings(4) Ground plate(4a) Slotted holes (4x) for mounting on

the foundation/ground

Sliding gate operator PULL T24, -T24speed

Technical dataSliding gate operator PULL- T24 T24speed T24 T24speedControl board intégrée Max. drive distance 30m

Power supplyMotor tension

230Va.c.50Hz24V d.c. Dutycycle(S3mode) 40–80%

Max. current consumption (excl. equipment) 1A Ambient temperature -20° +40°C

Gear wheel Z16M4 Z20M4 Protection class IP44

Max. gate weight 600kg 400kg Speed sensor

Speed 13m/min 16m/minArticle number 11110540 11110550

Torque 20Nm

Optional equipmentpluggable receiver • addtional module for courtyard lamp/control lamp • additional module for evaluation of gate status • bracket with cap rail included •radiotransmissionsystemTX310•inductive system TX 400i

* at low temperatures or with rough running gates a reduction in speed is possible depending on system used (24V DC motor)!

Motor selection by using a spring scale T5 T8 T10 T15 T24 T24speedAttach the spring scale to the gate at approx. the height of the rack. Then pull horizontallyandwithoutrockingatmotorspeed.Comparethemax.detectedtractive force with the guide values listed on the right.

up to 20kg

up to 30kg

up to 40kg

up to 60kg

up to 25kg

up to 20kg

Page 3: Sliding gate operator PULL T24, -T24speed81.223.229.147/part/E/E_PULL-T24-T24speed_290017.pdf · PULL T24, -T24speed features ... (KE) Connector for battery 24Vd.c. (optional) (KM)

tousek/E_PULL-T24-T24speed_29001705/23.04.2018 - 3 -

Main layer Sub layer Settings/adjustmentsbutton/switches impulse button OPEN/STOP/CLOSE

OPEN/CLOSE/OPENOPENDEAD MAN

*) if impulse button is set to DEADMAN, then the pedestrian and close button are also set automatically to DEADMAN mode. (not selectable under „pedest.- button“))

pedestrian button OPEN/STOP/CLOSEOPEN/CLOSE/OPENOPEN Impulse OPENDEAD MAN *)

safety G photocell activenot active

G main safety edge active radio edge TXTX 400not active

G side safety edge active radio edge TXTX 400not active

photoc.-function when closing reversestop - after release openduring close stop, then close

PHC-pause time noinfluenceofphotocellabort of pause time re-start of pause time immediate close after opening

PHC-self test activenot active

motor max. force 50...100% [increment 5 ] = 100%

ARS-response time 0,15...0,95s [increment 0,05] = 0,50s

speed 55...100% [increment 5] = 100%

soft stop way 0...2m [increment 0,1] = 0,5m

soft speed 10...50% [increment 5] = 40%

limit position OPEN 0...-30 [increment1] = -5

limit position CLOSE 0...-30 [increment1] = -5

operating mode impulse mode stop, start of pause time impulse suppression when openingpause time extension

G opening direction <<<– left–>>> right

G operating mode impulse modeaut. close 1...255s [increment 1]

partial opening 10...100% [increment 1] =30%

automatic mode complete/partial openingonly complete openingonly partial opening

pause time logic noinfluencealways open in automatic mode

lights/lamps prewarning OPEN OFF,1...30s = OFF

prewarning CLOSE OFF,1...30s = OFF

additional module yard/control lightstatus display 1status display 2

courtyard light 1) OFF, 5...950s = OFF

control lamp 1) illuminates when opening/closingblinks slowly / illuminates / blinks illuminates in open position

diagnosis status display status display of all inputs

delete position NOYES

factory setting NOYES

software version show software version

serial number show serial number

protocol show protocol notes

status sensor show sensor

1) The menu points courtyard lamp and control lamp will only appear on display if in menu „Additional module" courtyard lamp/control lamp is selected.

Menu structure Adjustments - overview

+

integr. control board for sliders PULL T24, -T24speed

ESC ENTER

Note

: som

e ad

just

men

ts re

gard

ing

func

tion

or o

pera

ting

logi

c ca

n on

ly b

e ex

ecut

ed if

gat

e is

clo

sed

and

if th

e di

spla

y sh

ows

„rea

dy“.

Page 4: Sliding gate operator PULL T24, -T24speed81.223.229.147/part/E/E_PULL-T24-T24speed_290017.pdf · PULL T24, -T24speed features ... (KE) Connector for battery 24Vd.c. (optional) (KM)

- 4 - tousek/E_PULL-T24-T24speed_29001705/23.04.2018

ground connection

Grounding

The grounding connection is made on the operator housing with the designated grounding screw!

K

F

FE ZM

S

D

Elements of control board

(K) Terminal blocks(KE) Connector for battery 24Vd.c. (optional)(KM) Motor clamps(KN) Power supply low tension 24Vd.c.(S) Sensor plug(D) Display plug

(FE) Slot for optional radio receiver(ZM) Connection slot for optional module(F) Safety fuse T 4A

1918

KE– +

KM– +

KN– +

Overview of the control unit

Control board Sliding gate operator PULL T24, -T24speed

Important

The optional tousek- service-interface must be connected with socket (D)!

Attention

During connection, adjustment and maintenance works please take care, that the electronic circuit board won´t be damaged by moisture (rain).

Page 5: Sliding gate operator PULL T24, -T24speed81.223.229.147/part/E/E_PULL-T24-T24speed_290017.pdf · PULL T24, -T24speed features ... (KE) Connector for battery 24Vd.c. (optional) (KM)

tousek/E_PULL-T24-T24speed_29001705/23.04.2018 - 5 -

Terminal assignment Sliding gate operator PULL T24, -T24speed

Attention

• Before taking off the control cover, the mains switch must be turned off!

• If the control is power supplied, its inner part is under tension.

• In order to avoid electrical strokes, the safety regula-tions have to be kept.

• The device may only be connected by trained profes-sionals

• The product is not suitable for installation in explosion-hazardous areas.

• An all-pole disconnecting mains switch with a contact opening gap of min. 3 mm has to be foreseen. The gate facility has to be secured according to the valid safety regulations!

• IMPORTANT: The control lines (buttons, radio, pho-tocells, etc.) have to be laid separately from the 230V lines (supply line, motors, signal lamp).

The stop input has no emergency stop function! - In order to ensure the emergency stop function, provide the supply line with an all-pole disconnecting emergency stop switch, that locks after actuation!

signal lamp 230V, 100W

power supply 230V a.c.

violet input switch-mode power supplyviolet 230V a.c.

Contact for photocellCommon PHC-contactPower supply photocell receiverPower supply photocell transmittercommon photocell

Main safety sensing edgeSide safety sensing edgecommon contact safety edgePedestrian-switchCLOSE-switchcommonImpulse-switch

STOP-contact

grey

ba

ttery

con

nect

ion

24Vd

.c. (

optio

nal)

yello

wbl

ack

mot

or 2

4Vre

dbl

ue

Con

nect

ion

bloc

k su

pply

and

oran

ge

supp

ly m

ax. 2

4Vd.

c., 5

W

(a

cces

sory

)

p r e - w i r e d

4041

4345

4631

3732

3033

3452

5150

114

1015

11

L N

8.k28.k2

8584 161918 17

– + – +

L N

– +

-

-

+

24V=

24V=

Terminals 40/41 and 40/43 in gate position CLOSE (ready for use) are in eco mode (= without tension).

Important: no external ac-cessories are allowed on these terminals!

N

Safety sensing edges

Function main safety sensing edge (MCE): Safety during closingFunction side safety sensing edges (SE): Safety during opening

MCE

SE

CLOSE OPEN

If no stop switch is connected, termi-nals 31/37 have to be wire-bridged.

Page 6: Sliding gate operator PULL T24, -T24speed81.223.229.147/part/E/E_PULL-T24-T24speed_290017.pdf · PULL T24, -T24speed features ... (KE) Connector for battery 24Vd.c. (optional) (KM)

- 6 - tousek/E_PULL-T24-T24speed_29001705/23.04.2018

NO

TE c

once

rnin

g ca

ble

layi

ng Th

e el

ectri

c ca

bles

hav

e to

be

laid

in in

sula

ting

slee

ves

whi

ch a

re s

uita

ble

for u

nder

grou

nd u

s-ag

e. T

he in

sula

ting

slee

ves

have

to b

e le

ad in

to

the

inne

r of t

he o

pera

tor h

ousi

ng.

230Vcablesandcontrollineshavetobelaidin

sepa

rate

sle

eves

.O

nly d

oubl

e-in

sula

ted

cabl

es, w

hich

are

suita

ble

for u

nder

grou

nd u

sage

(e.g

. E-Y

Y-J)

may

be

used

.In

cas

e th

at s

peci

al re

gula

tions

requ

ire a

noth

er

type

of c

able

, cab

les

acco

rdin

g to

thes

e re

gula

-tio

ns h

ave

to b

e us

ed.

SA

FETY

NO

TEPl

ease

be

awar

e th

at t

he b

esid

e pi

ctur

e is

onl

y a

sym

bolic

sam

ple

illus

trat

ion

of a

gat

e fa

cilit

y an

d m

ay

ther

efor

e no

t sho

w a

ll sa

fety

dev

ices

requ

ired

for y

our

spec

ific

appl

icat

ion.

To a

chie

ve a

n op

timum

saf

ety

leve

l at y

our g

ate

faci

l-ity

, ple

ase

mak

e su

re th

at a

ll sa

fety

com

pone

nts

and

acce

ssor

ies

whi

ch -

acco

rdin

g to

the

appl

ying

saf

ety

rule

s an

d la

ws

- are

req

uire

d in

you

r pa

rtic

ular

cas

e (e

.g. p

hoto

cells

, indu

ctio

n lo

ops,

sens

ing

edge

s, si

gnal

la

mps

, tra

ffic

light

s, m

ains

- and

em

erge

ncy

pow

er o

ff sw

itche

s et

c.)

are

prop

erly

ins

talle

d, o

pera

ted,

and

se

rvic

ed.

In th

is c

onte

xt p

leas

e fo

llow

the

EU M

achi

ne D

irect

ive,

ac

cide

nt p

reve

ntio

n ru

les

and

law

s, a

s w

ell a

s ap

ply-

ing

EU- a

nd n

atio

nal s

tand

ards

in fo

rce

at th

e tim

e of

in

stal

latio

n an

d op

erat

ion

of th

e ga

te fa

cilit

y.Th

e To

usek

Ges

.m.b

.H. c

anno

t be

hel

d re

spon

sibl

e fo

r an

y co

nseq

uenc

es r

esul

ting

from

di

sreg

ard

of

appl

ying

sta

ndar

ds a

nd l

aws

durin

g in

stal

latio

n or

op

erat

ion

of th

e ga

te fa

cilit

y.

The

0,75

mm

2 con

trol

line

s ar

e sh

own

with

out

grou

nd le

ad. I

n or

der t

o fa

cilit

ate

conn

ectio

ns

we

reco

mm

end

usin

g fle

xibl

e w

ires

and

not

usin

g th

icke

r wire

s fo

r the

con

trol

line

s.

11

2x0,

75 m

m2

4x0,

75 m

m2

3x1,

5 m

m2

2x1,

5 m

m2

coax

ial c

able

2x0,

75 m

m2

1

2a

2a2b

4

3

5

7

8o8s 9

2b

10

6

7 m

ain

switc

h 16

A

Not

e:A

n al

l-pol

e di

scon

nect

ing

mai

n sw

itch

with

a c

onta

ct

opening-gapofminimum

3mmhastobeforeseen.

8 sa

fety

sen

sing

edg

e9

pow

er s

uppl

y sy

tem

TX

100

for m

ovin

g ga

te c

ompo

nent

s.

W

hen

usin

g ot

her p

ower

sup

ply

syst

em (e

.g. T

X20

0i)

10 c

onne

ctio

n so

cket

11 s

top

mom

enta

ry c

onta

ct s

witc

h

1 op

erat

or T

OU

SE

K P

ULL

T24

, -T2

4spe

ed2

a - o

uter

pho

toce

ll / b

- in

ner p

hoto

cell

3 an

tenn

a fo

r bui

lt-in

radi

o re

ceiv

er4

key-

oper

ated

con

tact

sw

itch

5signalflashinglight

6 fu

se 1

2A

C

able

pla

n

Slid

ing

gate

ope

rato

r PU

LL P

ULL

T24

, -T2

4spe

ed

Page 7: Sliding gate operator PULL T24, -T24speed81.223.229.147/part/E/E_PULL-T24-T24speed_290017.pdf · PULL T24, -T24speed features ... (KE) Connector for battery 24Vd.c. (optional) (KM)

tousek/E_PULL-T24-T24speed_29001705/23.04.2018 - 7 -

We reserve the right to change dimensions and technical specifications without prior notice.

Dimensioned drawing Sliding gate operator PULL T24, -T24speed

• Dimensions in mm

(1) lockable emergency release (euro standard cylinder) (2) gear wheel (3) cable entrance (4) ground plate (4a) slotted holes (4x) for mounting on foundation (5) display for programming

PULL -T24 -T24speed1) gear wheel Z16M4,r36 Z20M4, r442) gear wheel center 633) gear wheel top 99 107

1

2

5

A B

View B: View A:

306,5

133

63

316

206,5

22

1263,4

gear wheel 1) ge

ar w

hell

top

3)

gear

whe

el

cent

er 2)

3

272

48,5

40

8552

13,5

4

58,5

4a

309

119,

5

Page 8: Sliding gate operator PULL T24, -T24speed81.223.229.147/part/E/E_PULL-T24-T24speed_290017.pdf · PULL T24, -T24speed features ... (KE) Connector for battery 24Vd.c. (optional) (KM)

tousekE_PULL-T24-T24speed_2900170523.04.2018

This manual is the sole property of the TOUSEK Ges.m.b.H. and may not be made available to competitors. All rights reserved. No part of it may be reproduced without our prior written permission. We will not accept liability for any claims resulting from misprints or errors. This edition of the manual replaces all earlier publications of the same.

Additional module Sliding gate operator PULL T24, -T24speed

• The use of one of the addtional modules is optional.• Depending on which device, e.g. a Courtyard-/Control lamp is chosen or evaluation of gate status should be effected,

the corresponding module (Z) has to be plugged to the according slot/plug (ZM) of control board.• Additionally the corresponding value has to be selected in menu point „Additional module“.

Additional module Courtyard lamp/Control lamp • Ontheterminals12/13acourtyardlamp(H)

can be connected: 230V, max. 100W• On the terminals 70/71 a control lamp (K)

can be connected: 24Vd.c., max. 2W

Additional module Gate status display

• With potential free signal contacts K1 (Kl. 90/91) andK2(Kl.92/93)thegatestaturscanbeevaluatedintwo ways (see menu point „Additional module“).

• Contact load: 24Va.c./d.c., max. 10W

Z

ZM

6b

L N

12 13 70 71

H K

– +

90 91 92 93

Sign

al c

onta

ct K

1

Sign

al c

onta

ct K

2