slim brochure

12
in association with Autex ® New Zealand AnutoneSlim AnutoneSlim Brochure 1.4 May 2009 FABRIC WALL SYSTEMS www.anutone.com/fabrics.htm Design Flexibility of Fabric Walls

Upload: anutone-acoustics-limited

Post on 17-Mar-2016

231 views

Category:

Documents


2 download

DESCRIPTION

Design Flexibility of Fabric Walls FABRIC WALL SYSTEMS www.anutone.com/fabrics.htm AnutoneSlim Brochure 1.4 May 2009 in association with Autex ® New Zealand • Music rooms • Classrooms • Home theatres • Entranceways / corridors • Restaurants / bars / cafes • Lecture halls • Offices • Libraries • Retail fitouts 2

TRANSCRIPT

Page 1: Slim Brochure

in association withAutex® New Zealand

AnutoneSlim

AnutoneSlim Brochure 1.4May 2009

FABRIC WALL SYSTEMSwww.anutone.com/fabrics.htm

Design Flexibility of Fabric Walls

Page 2: Slim Brochure

Applications

• Offices

• Boardrooms

• Classrooms

• Lecture halls

• Libraries

• Entranceways / corridors

• Music rooms

• Bedrooms

• Showrooms

• Retail fitouts

• Motor homes

• Home theatres

• Restaurants / bars / cafes

2

Page 3: Slim Brochure

The coming together of Anutone India and Autex New Zealand for interiorsolutions, augurs well for space users in India and South Asia.

Walls need never be drab or boring again. AnutoneSlim wall coveringsprovide a colourful and practical solution with the freedom of design choice.

AnutoneSlim is the perfect choice for applications such as office, school,home and even yachts. AnutoneSlim is also ideal as a finish on officepartitions, exhibition panels and retail displays.

Keeping it quiet

AnutoneSlim acoustic wall coverings come with a 10-12mm polyesterbacking to create a multi-use wall covering with exceptional acousticproperties. Entire wall can be covered with AnutoneSlim reducingreverberated noise by approximately 40 per cent (NRC rating 0.4).With backings like AnutoneSmooth or MAT with AnutoneSynth AWthe NRC ratings can be increased upto 0.9.

With easy installation options AnutoneSlim is ideal choice for educationsectors, commercial offices, movie theatres, libraries, retail shops,restaurants and cafes, residential applications - anywhere where youneed a surface that can reduce noise and/or act as a noticeboard.

Exceptional features

AnutoneSlim is “hook and loop” receptive, while it is also pin and staplereceptive, eliminating unsightly pin holes in the wall.

Available in roll form allowing for greater design flexibility.

Available in six fashionable colours, offering complete design freedom tocomplement any decor.

The use of specialised non-woven manufacturing processes meansAnutoneSlim will not zip or fray.

Polyester fibre is safe, non toxic, recyclable, environmentally friendlyand highly resistant to fading.

AnutoneSlim is also stain and moisture resistant which means it won’trot or breakdown, providing years of good looks and service.

Complete design freedomwith AnutoneSlim

Caution! Colours printed are for indicativepurposes only. Actual fabric colours will differ.Please ask for current colours and samples.

Chilli Red Sanz

Nautilus Myst

Lime Simba

Aubergine Silhouette

3

Page 4: Slim Brochure

Installation Drawings

4

Page 5: Slim Brochure

Architectural SpecificationsGENERAL

1.01 Scope

A. Supply and install AnutoneSlim Wall System asmanufactured by Anutone Acoustics LimitedBangalore – India and as required by the ContractDocuments.

B. Related Work Elsewhere

• Preparation of smooth, flat and plumbsubstrate.

• Architectural Woodwork, Masonry, Doors andFrames, Hardware, Gypsum Drywall,Plastering, Ceilings, Wall Covering Painting andElectrical Work.

1.02 Standards

The AnutoneSlim Wall System shall have less spreadof flame & smoke developed in accordance withAS1530 Part 3 testing parameters.

1.03 Qualifications

The installation work of this Section shall be performedby an authorized applicator, licensed by themanufacturer.

1.04 Quality Assurance

A. The AnutoneSlim shall be pasted over thesubsurface directly with the use of AnutoneStick S7or on MAT Primer with AnutoneStrut CC22.

B. The AnutoneSlim border shall be pastedcompletely into the wall / MAT primer creating aclean crisp appearance devoid of raw edges orloose threads.

C. The AnutoneSlim shall be installed from the faceside after installing the core material and is securelyfastened to ensure perfect alignment.

1.05 Submittal

A. Submit manufacturer’s product specifications andsuch other data as may be required to showcompliance with the Contract Documents.

B. Submit in writing to the Owner, through the Architect,the manufacturer’s dealer certification.

C. Submit installation Dealer’s Limited Warrantyagainst defects in the AnutoneSlim materials andworkmanship.

D. Installation applicator shall submit a list with aminimum of five (5) comparable installations.

1.06 Product Handling

A. Store all materials off the ground and protectedfrom dirt and dust of construction operations.

B. Handle materials in a manner that will protect themfrom damage and soiling.

PRODUCTS

2.01 Acoustical Wall Treatment System

A. The system shall consist of site installed andfabricated, concealed AnutoneSlim System asmanufactured by Anutone Acoustics Limited

Contact details of manufacturer / Authorized dealer

1. The System Components shall consist of thefollowing items :a AnutoneStrut CC22b AnutoneSynth AW 10x25mm.c. AnutoneStick S7d. MAT White Primere. AnutoneSlim

B. AnutoneSlim : Shall be approved by the consultant/ applicator for its suitability. The Manufacturer shallsubmit the following information concerning theconsultant / applicator• Fabric Manufacturer• Width of Fabric• Contents• Color• Flame Retardant• Sample of fabric (at least 300mm x 300mm)• Built up samples (300mm x 300mm)

EXECUTION

3.01 Existing Conditions

A. Examine the condition of the substrate and theconditions under which the work of the Section is tobe performed. Notify the Contractor in writing aboutany unsatisfactory conditions. Do not proceed withthe work until the conditions have been corrected ina manner satisfactory to the installer.

B. Do not install acoustical wall panel fabric in anyspace until:• The space is enclosed and is weather tight.• All wet work have been completed and is dry.• Painting is completed and wall base and floor

covering installed.

• All adjacent and related work of other tradeshave been completed including, in partArchitectural Woodwork, Masonry, Doors andFrames, Hardware, Painting, Ceiling Grid,Electrical Work. etc

3.02 Installation

A. Field measure each wall area, which is to receivethe AnutoneSlim treatment to establish the exactlayout of the units as shown on elevations.

B. Prior to installation, walls and surfaces must beclean, dust free and void of any defects orimperfections. Dents and cracks should belevelled and sealed with proprietary and suitableinterior grade materials. All joints in thesubstrateshould be taped with a proprietary sealing tape tostop the ingress of dust and foreign particlestravelling from the wall cavity through to the fabric.

5

Page 6: Slim Brochure

C. Check Installed AnutoneSlim for plumb and straight,flush in proper alignment.

D. Cut AnutoneSlim from each roll to the requiredshape.

E. Install directly on the wall with AnutoneStick S7 or,on MAT primer mounted on CC22 (Grouted directlyto wall by using AnutoneStitch fasteners at every600mm centers) with a backing of AnutoneSynthAW 10x25mm.

F. Installation shall be timely and applicators shallbe courteous and cooperate with other trades

3.03 Cleaning and Protection

A. Clean exposed surfaces of wall as necessary,

comply with manufacturer’s instructions forcleaning and repair of minor finish damage.Remove and replace work that cannot besuccessfully cleaned and repaired to permanentlyeliminate evidence of damage.

B. The Installer shall advise the Contractor of requiredprotection, including soiling from other trades anddust control, so that the work will be withoutdamage and deterioration at the time ofacceptance by the Owner.

Tender SpecificationsSupply and Installation of AnutoneSlim Wall paneling System have a thickness of 10mm that can be installed directly on thewall with AnutoneStick S7 or, on MAT primer mounted on CC22 (Grouted directly to wall by using AnutoneStitch fasteners atevery 600mm centers) with a backing of AnutoneSynth AW 10x25mm.

AnutoneSlim (subject to change without prior notice)

Fibre 100% polyester fibre

Total Product Weight 1600gsm

Total Nominal Thickness 10-12mm

Roll Length/Width Standard 25m x 1.22m wide

Moisture Absorption 0.006%.Will not rot or smell

Fire Ratings AS1530 Part 3:Spread of Flame (Index 0-10)0Smoke Developed (Index 0-10)5-Tested April 2002, CSIRO

AS/NZS 3837:1998:Group Number 3Average Speci .c Extinction Area:157.7m 2 /kg-Tested August 2004,CSIRO

Care and Maintenance See page 7 of this document or ask your local distributor.

Installation Installation instructions are included in every pack of tiles, or see page 4-6of this document, or ask your local distributor.

Quality Standards Manufactured to ISO 9001 International Quality Standards

General Test result certificates are available upon request.

6

Page 7: Slim Brochure

Butt Jointing Method

It is imperative that you planyour installation prior tocutting into the product. Werecommend that you“measure twice -cut once.”

1 2 3 4

Lay a waste cloth onto thefloor before applyingAnutoneStick S7. Theadhesive must be applied tothe entire substrate beforehanging AnutoneSlim

Before hanging theremaining drops you mustensure the first butt joint istight and no gaps appear, aswith all joints when hangingAnutoneSlim

Roll the AnutoneSlimdrops towards the buttjoint first, then roll theentire drop.

• Before the AnutoneSlim drops are hung, they should be checked for any minor faults which should be cutout. Anallowance is given for agreed defects.

• AnutoneStick S7 should be applied strictly to the manufacturers instructions. Adhesives should be applied to thesubstrate with a roller, not onto the product.

• Any adhesive spills or fabric sur face contamination should be cleaned immediately as per the manufacturersrecommendations on the care and maintenance guide for this product.

• The job should be progressively checked and any variations in colour or appearance of variation must be reportedto Anutone immediately.

TOOLS REQUIRED • snap off knife • cutting board• tape measure • straight edge• hand roller • waste cloth• AnutoneStick S7 • 6-10mm pile roller and adhesive tray

General InformationWall and Surface Preparation

Prior to installation, walls and surfaces must be clean, dustfree and void of any defects or imperfections. Dents and cracksshould be levelled and sealed with proprietary and suitableinterior grade materials. All joints in the substrate should betaped with a proprietary sealing tape to stop the ingress ofdust and foreign particles travelling from the wall cavity throughto the fabric.

General Wall Use

Anutone recommends using putty formulations for semiporous and sealed surfaces such as matt painted timberand cementitious surfaces.

Very porous surfaces such as gypsum board should first besized with a proprietary sealer. Semi gloss and gloss finishesshould be lightly sanded and dusted prior to application.

Installation Guidelines

7

Page 8: Slim Brochure

Using Rigid ProfilesTOOLS REQUIRED – • snap off knife

• cutting board• tape measure• straight edge• hacksaw• hand roller• rigid profiles• AnutoneStick S7• staple gun and staples• 6-10mm pile roller and tray for the adhesive

It is imperative that you planyour installation prior tocutting into the product. Werecommend that you“measure twice -cut once.”

1 2 3 4

5 6 7 8

We recommend that youinstall the rigid profiles priorto hanging Composition.Staples can be used onsuitable substrates. Forconcrete surfaces useconstruction adhesive - thismust be used as permanufacturers instructions.

Using a piece ofComposition width,measure the spacebetween each H-Spline andmark where the H-Spline isto go, then staple the H-Spline in place.

Cut AnutoneSlim to therequired drop sizes. To avoidany variation in pile direction,ensure all drops are hung inthe direction. Use the arrowson the back of the product toensure you have the directionalarrows going the same way,either up or down.

Using the adhesive roller,apply the adhesive onto thewall - not the product.Leave a gap of 70mmeither side of the rigidprofiles to allow for tuckingthe product in.

Place the drops on the walloverlapping at the top andbottom.

Using the hand roller, rollthe product to ensureadequate adhesion of theproduct to the wall.

Tuck the product into the endcaps and top caps.

8

Page 9: Slim Brochure

Using External Corners

Before you staple the external corner in place,youmust measure the space required using a piece ofComposition to allow the product to be tucked underthe profile.

Using Internal Corners

Cut the internal profile to size and staple in place.Using the adhesive roller, apply the adhesive ontothe wall, leaving a 70mm gap either side of theinternal corner.

9

Page 10: Slim Brochure

AnutoneSlim range of products are extremely durable and require little attention to maintain their good looks. Light vacuumingon a regular basis will prevent dust build up and most marks can be cleaned with a mild detergent solution followed by rinsingand blotting. Stains should be dealt with according to the chart below.

• Before carrying out a proposed cleaning method, apply to a concealed section to ensure it will not affect the adhesive or wallcovering

• Avoid severe abrasion• Vacuum to restore pile, but do not use a stiff brush.

Note: Anutone does not recommend solvent based cleaners on AnutoneSlim

Anutone offers the above recommendations in good faith. However, Anutone cannot be responsible for unsatisfactory results arising from the proposed treatments

Anutone recommends that you contact professional cleaning experts should you require further assistance with the cleaningand maintenance of AnutoneSlim.

Maintenance Guidelines

A Mop up excess as soon as possible with a sponge or cloth.

B Remove surplus with a knife edge or appropriate instrument.

C Sponge with a solutions of carpet shampoo working from well outside the stain in a circular motion towards the centre(this avoids spreading the stain). Sponge afterwards with clean warm water and mop up excess moisture with a cleandry cloth or sponge. Allow to dry then brush gently with a soft brush. If any stain remains, sponge with a solution of one parthousehold bleach to six parts clear water. Thoroughly rinse after treatment.

D Lightly sponge with household dry cleaning fluid and blot. Apply sparingly, as the substance may have an adverse effecton the adhesive.

E Sponge with methylated spirits and blot dry.

G Apply nail polish remover. The nail polish remover should not include lanolin or be of a greasy nature.

H Sponge with turpentine (or substitute).

I Freeze with ice cubes and scrape away while cold.

J Clean with regular extractive carpet cleaner (if possible).

K Use circular cutter and remove damaged portion. Re-glue new piece into place.

Stain Treatment Guide Stain Treatment GuideBlood A C Lipstick B E C DBurn/Scorch Mark K Mildew CChewing Gum I B D C Milk A EChocolate B D C Mud B CCooking Oils B D C Nail Polish A GCrayon/Colour Markers B D C Oil B D CDrinks (cola, tea, juices, beer etc) A C Paint (water based) A CDust/Dirt Vacuum, then J or C Paint (oil based) A H D CExcrement B C Sauces B C DGrass C Shoe Polish B C DGrease B D C Urine A CInk (ballpoint) D E Vomit A C DInk (fountain) A C Wine A Add Salt C

10

Page 11: Slim Brochure

Technially, a typical AnutoneSlim wall panel system comprises visually with or without track material, and acousticallyperforming core material. Each of these material will have two each componets, in addition to the surface finish and aspecial adhesive. The specs of these materials, for a typical model, can be:

Material Specifications

TECH PRIMER

Sl# Description AnutoneSlim

1 Thickness (mm) 10 / 12

2 Size (mm) Width upto 1200mm / Length upto 25000 (1 Roll)

3 Core High Density Polyester fibres

4 Nominal Density (Kg/m3) NA

5 Weight (Kg/m2) 1600gsm

6 Edge Square

7 NRC / STC Upto 0.75

8 Fire Class A

9 Moisture Resistance (%) RH 90

10 Light Reflectance (%) Color Dependent

11 Warranty 5 Years

12 Installation Directly to the wall / Mat by using adhesive

13 Color 8 Colors

14 Maintenance Vacuum & Cleaning with mild detergent solutions

Sl # Description Units AnutoneSlim Composition

Direct on wall CC 22 mounting

Thickness mm 10-12 54-56

1 AnutoneStrut CC22 @600 C/C vertically - - 169.2

2 MAT 600 X 20 - - 100

3 AnutoneSynth AW m2 - 100

4 AnutoneStick S7 Ltrs 35 70

5 Fabric - 100 100

6 Labour hrs

Estimated Installed Cost / m2 Rs 2300 4400

BILL OF QUANTITIES (BOQ) - 100M2

Assuming area 100m2 (Length 10m & Height 10m)

Abbreviation – lm - Linear meter, m2 - Square meter, Ltr - Litre, LS - LumpSum, hrs - Hours

11

* The above indicated values are very approximate and dependent on several variables. They are for guidance only and subject to change without prior notice.

Page 12: Slim Brochure

Do

cum

en

t #

90

90

10

-50

0

231, 7th Cross, Indiranagar 1st Stage,Bengaluru 560 038, IndiaPhone +9180 2520 3114Fax +9180 2520 [email protected]

ANUTONE INTERIORS(a division of Anutone Acoustics Limited)

Anutone® is a registered trademark of Anutone Acoustics Limited. Specs are subject to change due to continuous improvement programmes at Anutone®. Contents under copyright registration. No part of thisbrochure may be reproduced, stored in a retrieval system, scanned or transmitted in any form or by any means electronic, photocopying, recording or otherwise, without the prior written permission of Anutone®.

www.anutone.com

• Bahrain • Budapest • Chennai • Dammam • Doha• Dubai • Jeddah • Kolkata • Kuwait • Manila• Mumbai • Muscat • Nairobi • New Delhi • Riyadh

Anutone is member of

ISO 9001:2008 CERTIFIED ISO 14001:2004 CERTIFIED