Page 2: Slope Stabilization with Steel H-Piles

Overview

• Project site – landslide features and subsurface conditions

• Slope stability – existing and stabilized • Lateral pile design – distribution of lateral load • Pile layout • Construction

Page 3: Slope Stabilization with Steel H-Piles

Site Location

Source: ESRI, Digital Globe, GeoEye, i-Cubed

Page 4: Slope Stabilization with Steel H-Piles

N

Source: ESRI, Digital Globe, GeoEye, i-Cubed

Site Location

Page 5: Slope Stabilization with Steel H-Piles

Scarp

Page 6: Slope Stabilization with Steel H-Piles

Damage along Old SR 15

Page 7: Slope Stabilization with Steel H-Piles

Plan View

SCARP

CRACK

SR 15

MASW B

MASW A

BULGE RESERVOIR

1303+00 1300+00

6 PIEZOMETERS 10 INCLINOMETERS

PVMT BULGE

WATER

Page 8: Slope Stabilization with Steel H-Piles

Subsurface Profile – Station 1303+00

φ=16.4º φ=25º φ=36º (RESIDUAL) (PEAK)

OLD SR 15

Page 9: Slope Stabilization with Steel H-Piles

Geophysics Profile along Old SR 15

Deformation in Inclinometers

Page 10: Slope Stabilization with Steel H-Piles

Slope Stability

• GSTABL7 – Wedge • Existing slope without piles: FS = 1.0 • Remediated slope with piles: FS = 1.3

– Pile resistance input as lateral load – Lateral load input per foot of embankment

PILE

Page 11: Slope Stabilization with Steel H-Piles

Pile Design

• Computer software LPILE • Lateral load triangularly distributed • p-multiplier • Pile tip fixity • Moment criteria for MMAX ≤ MRESISTING • Pile layout

Page 12: Slope Stabilization with Steel H-Piles

Lateral Load Distribution

Ground Surface

Failure Surface

Pile

𝑃𝑃 = 2 ∗𝐹𝑃

𝐿𝐿𝐿𝐿𝐿𝑃∗𝑃𝑃𝐿𝑃 𝑆𝑃𝑆𝑆𝑃𝑆𝑆

# 𝑅𝑅𝑅𝑆

Pile Layout – Plan View

I I I I I I I

I I I I I I

I I I I I I I

I I I I I I

Fh

Length

Triangular distribution per ODOT (2011) Geotechnical Bulletin 7

Page 13: Slope Stabilization with Steel H-Piles

Lateral Load Distribution - Example

Ground Surface

Failure Surface

Pile Pile Layout – Plan View

I I I I I I I

I I I I I I

I I I I I I I

I I I I I I

75 kpf

35 ft 𝑃𝑃 = 2 ∗

75 𝑘/𝑓𝐿35 𝑓𝐿

∗6 𝑓𝐿

4 𝑟𝑟𝑟𝑟

= 6.43 kips/ft per pile = 536 lbs/in

6 ft

Page 14: Slope Stabilization with Steel H-Piles

Lateral Load Distribution - Example

Ground Surface

Failure Surface

Pile

35’ = 420” 𝑃𝑃 = 2 ∗

75 𝑘/𝑓𝐿35 𝑓𝐿

∗6 𝑓𝐿

4 𝑟𝑟𝑟𝑟

= 6.43 kips/ft per pile = 536 lbs/in

Page 15: Slope Stabilization with Steel H-Piles

Subsurface Profile for Lateral Pile Analysis

• Reduction to soil resistance (p-y curves) – Active landslide – Pile spacing:diameter – FS in front of pile – p-multiplier = 0. 231

Ref: ODOT (2011) GB 7

Page 16: Slope Stabilization with Steel H-Piles

Lateral Pile Analysis Results (HP 12x53)

MMAX = 1,744 kip-in <

MRES = 1,983 kip-in

VMAX = 41 kips <

VRES = 98 kips

Just for interest δ = 2.2 in.

Page 17: Slope Stabilization with Steel H-Piles

Piles Layout

SCARP

3 ROWS 4 ROWS

Design: 462 PILES

Page 18: Slope Stabilization with Steel H-Piles

Piles Layout

Page 19: Slope Stabilization with Steel H-Piles

Test Piles

Page 20: Slope Stabilization with Steel H-Piles

Test Piles

Page 21: Slope Stabilization with Steel H-Piles

Test Piles

Page 22: Slope Stabilization with Steel H-Piles

Test Piles

20+ BPF

PDA > 150 KIPS

L=50’

L=50’ L=55’ L=55’

L=45’ L=45’

DESIGN PILE LENGTH

L=35’ L=40’

Page 23: Slope Stabilization with Steel H-Piles

Production Driving

Photo courtesy of Glenn O. Hawbaker, Inc.

Page 24: Slope Stabilization with Steel H-Piles

Production Driving

Photo courtesy of Glenn O. Hawbaker, Inc.

Page 25: Slope Stabilization with Steel H-Piles

Production Driving

Page 26: Slope Stabilization with Steel H-Piles

Pile Quantities

SCARP Design: 8 test piles with total length = 465 LF 454 production piles with total length = 22,325 LF Construction: 29 piles lengthened by 5’ 10 piles added with L = 60’

∆ Total Length = 3%

Page 27: Slope Stabilization with Steel H-Piles

Summary

• Slope failure and subsurface conditions • Existing slope model calibrated to FS = 1.0 • Slope stability

– FS=1.3 Strength limit state of lateral pile load • Lateral pile design

– Lateral load triangularly distributed – p-multiplier

• Pile layout based on geophysics profile • Quantity of installed piles only 3% > design

Page 28: Slope Stabilization with Steel H-Piles

Acknowledgements

Thank you!

Photo courtesy of PennDOT