Slow Ground Motion Studies at Fermilab
James T Volk
Accelerator Division
Andrey Chupyra, Shavkat Singatulin, Budker Institute of Nuclear Physics
Vladimir Shiltsev, Sten Hansen, Terry KiperFermilab
Principle that water seeks its own level
There are two types of HLS systems in use
James T Volk May 2009
Budker Institute of Nuclear Physics
Fermilab designed Tevatron style
Balluff proximity sensor
Capacitive sensor
Water pool
Air line
Water line
Fermilab Design Tevatron Style
James T Volk May 2009
8 channel readout card Ether net interface
Balluff sensor and pool
Power supplyRS232 port
Paper in IWAA-08 J Volk
Tevatron Sensors on Quad
James T Volk May 2009
In the circle is a water level pot on a Tevatron quadrupole
Air Line
Water line
Difference in sensors on CQ5 and DQ5
James T Volk May 2009
Date
Mic
ro m
eter
s
B3 Dumped burned upChanges in tunnel temp and pressure
Layout of MINOS water level
James T Volk May 2009
MINOS detector
30 meters30 meters30 meters
Not to scale
direction
Sensor
Water line
Depth of floor 100 meters below grade406 feet above sea level Maquoketa shale
Location of Horizontal andVertical seismometer New
sensors
James T Volk May 2009
FFT of MINOS data difference between two sensors
December 2007
0.0 1.0x10-4 2.0x10-4 3.0x10-4 4.0x10-4 5.0x10-4 6.0x10-4 7.0x10-4 8.0x10-4
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
Frequency (Hz)
Am
plit
ude
12 hours tidesFFT of MINOS data L3-L0 sensors
59 minutes