sm00053 d
TRANSCRIPT
AR3200CAR3200C
SM00053Revision D
Automated Iron RoughneckService Manual
July 1, 2005
ii AR3200 SM000053, Rev D
Copyright 2005, Varco International, Inc.
All rights reserved. This publication is the property of and contains information proprietary to Varco International, Inc. No part of this publication may be reproduced or copied in any form or by any means, including electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Varco International, Inc.
Product names mentioned in this publication may be trademarks or registered trademarks of their respective holders and are hereby acknowledged.
Contents iii
Contents
PrefaceManual conventions ............................................................................................ xi
Safety information ........................................................................................ xiProduct Bulletins ......................................................................................... xiiDirectional references .................................................................................. xiiPLC configurations ...................................................................................... xiiIllustrations .................................................................................................. xii
Varco Service Centers ........................................................................................ xii
Chapter 1 DescriptionGeneral description ........................................................................................... 1-5
Makeup mode ..............................................................................................1-5Breakout mode ............................................................................................ 1-6Operator controls .........................................................................................1-6
Manual Control Station ........................................................................ 1-6Operating in manual mode ..............................................................1-6
Automatic Control Station ................................................................... 1-6Tool J-box controls .............................................................................. 1-7
Major component description ............................................................................ 1-8Chassis assembly ...................................................................................... 1-10
Frame .................................................................................................. 1-10Carriage .............................................................................................. 1-10Drive foot assemblies ......................................................................... 1-12
TW-102 Hydraulic Torque Wrench assembly .......................................... 1-14Soft clamp feature .............................................................................. 1-14
SSW-50 Spinning Wrench assembly ........................................................ 1-16Electrical control system ........................................................................... 1-18
Power distribution .............................................................................. 1-18Systems with optional purge systems............................................1-19
PLC assembly and enclosure ............................................................. 1-21Siemens PLC .................................................................................1-21Central Processing Unit (CPU) microprocessor ............................1-21CPU Random Access Memory (RAM) .........................................1-21Erasable Programmable Read-Only Memory (EPROM) slot .......1-22Backup battery...............................................................................1-22Input/Output (I/O) interface...........................................................1-23PLC power supply .........................................................................1-23Digital I/O module.........................................................................1-23Solenoid drivers.............................................................................1-23Power supply (encoder) .................................................................1-25
iv AR3200 SM00053, Rev D
IS isolation amplifiers and Zener barriers......................................1-25Expo PLC purge air system (optional) ..........................................1-25
Position and proximity sensors/switches ............................................ 1-26 Hydraulic system ..................................................................................... 1-30
Hydraulic manifold assembly ............................................................. 1-30Pressure-reducing Valve (PRV) ......................................................... 1-30Lift cylinder circuit ............................................................................. 1-31Linear position slave cylinder assembly ............................................ 1-31Horizontal travel circuit ...................................................................... 1-31Spinning wrench clamp circuit ........................................................... 1-31Spinning wrench spin circuit .............................................................. 1-31Tilt cylinder circuit ............................................................................. 1-32Torque wrench clamp circuit .............................................................. 1-32Torque cylinders makeup and breakout circuit .................................. 1-33NFPA 496 Type Y roughneck J-box purge system
(UL only) .......................................................................... 1-33Internal Blow Out Preventer (IBOP) hanger kit (optional) ................ 1-33
Specifications .................................................................................................. 1-34Other specifications .................................................................................. 1-37
Drive rails/adapter plates ...............................................................1-37Spinning wrench (pipe spinner).....................................................1-37Torque wrench ...............................................................................1-38Horizontal movement ....................................................................1-38Vertical movement.........................................................................1-38Tilt movement................................................................................1-39
Main materials of construction (type and grade) ...................................... 1-40Cylinders........................................................................................1-40Hydraulic hose ...............................................................................1-41
Chapter 2 InstallationUnpacking and handling procedure ................................................................... 2-5Short and long term storage ............................................................................... 2-6Initial inspection ................................................................................................ 2-6Preinstallation requirements .............................................................................. 2-7
General requirements .................................................................................. 2-7Electrical requirements ............................................................................... 2-7Hydraulic requirements ............................................................................... 2-7Pneumatic requirements .............................................................................. 2-8UL tool J-box purge system requirements .................................................. 2-8PLC purge system requirements ................................................................. 2-8Special tools and support equipment .......................................................... 2-8
Installation procedures ....................................................................................... 2-9Referenced drawings ................................................................................... 2-9Component installation ............................................................................. 2-10
Installing the AR3200 adapter plate ................................................... 2-10Installing the AR3200 rails ................................................................. 2-11
SM00053, Rev D Contents v
Installing the AR3200 assembly ........................................................ 2-12Installing the derrick J-box mounting plate and hydraulic derrick plate assembly .................................................................................... 2-14
Derrick J-box mounting plate ....................................................... 2-14Hydraulic derrick plate assembly ................................................. 2-14
Installing the hydraulic pressure transducer ....................................... 2-17Installing the hydraulic torque gauge ................................................. 2-18Installing the hydraulic service loop .................................................. 2-19Interconnecting purge air (UL configurations) .................................. 2-20Installing the monitor and optional control stations ........................... 2-21
Control station options.................................................................. 2-21Installing the AC voltage regulator .................................................... 2-23
Nonpurged installation ................................................................. 2-23UL and EEx installation ............................................................... 2-23General notes ................................................................................ 2-23
Installing the PLC enclosure (nonpurged) ......................................... 2-24Installing the optional PLC enclosure purge unit ............................... 2-24Installing the electrical service loop ................................................... 2-25
Chapter 3 OperationAR3200 operator controls ................................................................................. 3-5
About the operator control panels ........................................................ 3-5Torque gauge ................................................................................. 3-5
Automatic Sequence controls ............................................................... 3-6Controls in sequenced operation .................................................... 3-6Controls in manual mode ............................................................... 3-7EMERGENCY STOP (ESD) control ............................................ 3-7
Tool J-box controls .............................................................................. 3-7Manual Control Station ........................................................................ 3-7
Automatic Control Station ........................................................... 3-10Remote Monitor Station ..................................................................... 3-11Optional Remote Control Station ....................................................... 3-13Tool J-box controls ............................................................................ 3-15
Preoperation .................................................................................................... 3-16Preoperational checklist ............................................................................ 3-16
AR3200 PLC startup .......................................................................... 3-21Installing the EPROM ........................................................................ 3-21Indexing the AR3200 ......................................................................... 3-22Initializing an automatic sequence ..................................................... 3-23Setting up the AR3200 LEARN MODE ............................................ 3-24
AR3200 function tests .............................................................................. 3-26Function checks .................................................................................. 3-26
Pressure-reducing valve ............................................................... 3-26Torque Wrench ............................................................................ 3-27Spinning Wrench ......................................................................... 3-27Carriage vertical positioning ....................................................... 3-27Rolling operations ........................................................................ 3-27
vi AR3200 SM00053, Rev D
Tilt operation ................................................................................ 3-27Automatic makeup ....................................................................... 3-28Automatic breakout ...................................................................... 3-29Semiautomatic makeup with manual height positioning ............. 3-30Semiautomatic breakout with manual height adjustment ............ 3-31Automatic makeup, PS MODE .................................................... 3-32Automatic breakout, PS MODE .................................................. 3-33Automatic makeup, Torque Wrench backup mode (soft clamp) . 3-34Automatic breakout, Torque Wrench backup mode (soft clamp) 3-35LEARN MODE ........................................................................... 3-36
Operating procedures ....................................................................................... 3-37AR3200 checkout procedures ................................................................... 3-37Manual control switches ........................................................................... 3-38
Setting the makeup torque ........................................................... 3-38Mousehole operations ......................................................................... 3-39End-of-stroke interlock ....................................................................... 3-40
Resetting after an interlock condition .......................................... 3-40Automatic sequence control ...................................................................... 3-41
Torque Wrench backup mode ............................................................ 3-41Automatic makeup ............................................................................. 3-42Automatic breakout ............................................................................ 3-43Auto/manual height adjustment operation ......................................... 3-44
Manual positioning mode ............................................................ 3-44Autopositioning mode .................................................................. 3-44
Tool joint length and tool joint height ................................................ 3-45Horizontal/vertical position adjustments ............................................ 3-46
Purge operation ................................................................................................ 3-47Operating the purge unit for PLC enclosure ............................................. 3-49Operating the J-box purge control unit ..................................................... 3-50
IBOP hanger operation (optional) ................................................................... 3-52Commissioning Procedure (FIP00055) ........................................................... 3-52
Chapter 4 MaintenanceGeneral inspection requirements ....................................................................... 4-5
Scheduled inspection requirements ............................................................. 4-6Removal and installation procedures ............................................................... 4-13
Mechanical components ............................................................................ 4-13Tong die .............................................................................................. 4-13
System hydraulic components .................................................................. 4-14Inlet pressure gauge ............................................................................ 4-14Torque gauge ...................................................................................... 4-15Torque adjustment valve .................................................................... 4-16Dump valve ........................................................................................ 4-17Pressure-reducing valve ..................................................................... 4-18Carriage lift cylinders ......................................................................... 4-19Spinning Wrench main motors ........................................................... 4-20
SM00053, Rev D Contents vii
Spinning Wrench jaw motors ............................................................. 4-21Pressure-reducing valve (2,000/2,500 psi) ......................................... 4-22Speed control valve ............................................................................ 4-23Foot motor .......................................................................................... 4-23
Control manifold hydraulic components .................................................. 4-24EEx and UL directional control valves .............................................. 4-26
Electrical components ............................................................................... 4-27Tool joint position sensor ................................................................... 4-27Torque jaw position sensor ................................................................ 4-28
Adjustment procedures .................................................................................... 4-29Adjusting the Spinning Wrench speed control ......................................... 4-29Adjusting the carriage lift counterbalance ................................................ 4-30Adjusting the vertical travel speed ........................................................... 4-30Adjusting the horizontal travel speed ....................................................... 4-30Adjusting the tilt cylinder speed control ................................................... 4-31Adjusting the regenerative valves of the torque wrench clamp cylinder .. 4-31Adjusting the manual torque pressure control valve ................................ 4-32Adjusting the hydraulic pressure relief valve ........................................... 4-32Adjusting the wear plate and tool joint detector sensor ............................ 4-32Adjusting the torque wrench position sensor ............................................ 4-33Adjusting the torque wrench dump valve ................................................. 4-33Adjusting the horizontal index sensor ...................................................... 4-34Adjusting the 2,500 psi hydraulic pressure valve ..................................... 4-34Adjusting the 2,000 psi hydraulic pressure valve ..................................... 4-35Adjusting the horizontal position sensor .................................................. 4-35Adjusting the spinout sensor ..................................................................... 4-35Adjusting the tool joint length switch voltage supply .............................. 4-36Adjusting the end-of-stroke proximity sensor .......................................... 4-36Adjusting the stabbing guide .................................................................... 4-36
Chapter 5 LubricationLubrication schedules ........................................................................................ 5-5Lubrication procedures .................................................................................... 5-10
Lubricating the frame and carriage ........................................................... 5-10Lubricating the foot assemblies ................................................................ 5-11Lubricating the tilt lever ........................................................................... 5-12Lubricating the TW-102 Hydraulic Torque Wrench ................................ 5-13Lubricating the SSW-50 Spinning Wrench Assembly ............................. 5-14
viii AR3200 SM00053, Rev D
July 1, 2005
Chapter 6 TroubleshootingTroubleshooting components ............................................................................ 6-5
Troubleshooting mechanical components ................................................... 6-6Torque Wrench ................................................................................... 6-11Spinning Wrench ................................................................................ 6-14
Troubleshooting hydraulic circuits and valves ......................................... 6-16Pressure-reducing valve circuit (PRV) ............................................... 6-17Lift cylinder circuit ............................................................................. 6-19Horizontal travel circuit ...................................................................... 6-20Spinning Wrench clamp circuit .......................................................... 6-21Spinning Wrench spin circuit ............................................................. 6-22Tilt cylinder circuit ............................................................................. 6-23Torque Wrench clamp circuit ............................................................. 6-24
Soft clamp mode .......................................................................... 6-24Torque cylinders circuit ...................................................................... 6-25Directional valves ............................................................................... 6-26
About directional solenoid-controlled valves .............................. 6-26General diagnostic procedure for solenoid-controlled valves ..... 6-26Isolating a faulty solenoid-operated directional valve ................. 6-27Repairing a stuck spool ................................................................ 6-27Two-position, solenoid-operated, four-way, (spring offset) ........ 6-28Three-position, solenoid-operated, four-way (spring-centered),float center ................................................................................... 6-29Three position, pilot-operated, solenoid controlled, four-way (spring-centered), float center ...................................................... 6-30
Load-holding valves ........................................................................... 6-32Counterbalance valve, pilot assisted ............................................ 6-32Relief valve, pilot-operated .......................................................... 6-35Check valve, pilot-operated ......................................................... 6-37
Pressure control valves ....................................................................... 6-39Pilot-operated, pressure-reducing valve ...................................... 6-39
Auxiliary valves ................................................................................. 6-41Check valve, pilot-to-close .......................................................... 6-41Check valve .................................................................................. 6-43
Flow valves ......................................................................................... 6-44Orifice .......................................................................................... 6-44Pressure-compensated, fixed orifice ............................................ 6-45Flow control valve, adjustable, pressure compensated, full reverse free flow .................................................................... 6-47
Output actuators ........................................................................................ 6-49Hydraulic cylinders ............................................................................ 6-49Hydraulic motors ................................................................................ 6-51
Troubleshooting electrical and control system components ........................... 6-53Causes of malfunction ............................................................................... 6-53AR3200 control system ............................................................................. 6-53Troubleshooting the PLC .......................................................................... 6-56
Last resort PLC troubleshooting procedure ........................................ 6-56
SM00053, Rev D Contents ix
PLC power supply .............................................................................. 6-62Digital input/output module ............................................................... 6-62Control system inputs ......................................................................... 6-65
Encoders ...................................................................................... 6-65Proximity sensors ............................................................................... 6-66Intrinsic safety devices ....................................................................... 6-67
Zener safety barriers .................................................................... 6-67Intrinsically safe amplifiers ......................................................... 6-68Transformer isolated barriers ....................................................... 6-70
Chapter 7 Supplemental MaterialsSupplement list .................................................................................................. 7-5
Chapter 8 DrawingsDrawings by assembly ...................................................................................... 8-5Drawings in numerical order ............................................................................. 8-7
x AR3200 SM00053, Rev D
July 1, 2005
Preface xi
Preface
Manual conventionsThis Preface contains the conventions used throughout this manual. Avoid injury to personnel and/or equipment damage by reading this manual and related documents before operating, inspecting, or servicing the equipment.
Safety informationThe following examples explain the symbols for notes, cautions, and warnings. Please pay close attention to these important advisories.
Note
z Provides additional information on procedures involving little or no risk of injury to personnel or equipment damage.
Caution
e Alerts the reader to procedures involving a risk of equipment damage.
Warning
n Warns the reader of procedures involving a definite risk of injury to rig personnel.
xii AR3200 SM00053, Rev D
July 1, 2005
Product BulletinsThe Product Bulletin tab defines a section of the manual in which you can store Product and Safety bulletins that may be issued from time to time by Varco.
Directional referencesReferences to locations to the right or left of components described in this manual assume the perspective of the tool assembly itself (e.g., the torque gauge located on the roughneck is defined to be on the right side of the tool).
PLC configurationsThe PLC configurations described in this manual are typical, but not universal. See your Technical Drawings Book for rig-specific information.
IllustrationsFigures present a graphical representation of tool components for use in identifying parts or establishing nomenclature.
For more specific component information pertinent to your rig configuration, see the technical drawings that accompany your Varco documentation.
Varco Service CentersIf you need technical assistance, see the back cover of this manual for a complete list of Varco’s Worldwide Service Centers.
AR3200
AutomatedIronRoughneck
Description
July 1, 2005
1-2 AR3200 SM00053, Rev D
Description 1-3
Chapter 1 Contents
Chapter 1 DescriptionGeneral description ........................................................................................... 1-5
Makeup mode ..............................................................................................1-5Breakout mode ............................................................................................ 1-6Operator controls .........................................................................................1-6
Manual Control Station ........................................................................ 1-6Operating in manual mode ..............................................................1-6
Automatic Control Station ................................................................... 1-6Tool J-box controls .............................................................................. 1-7
Major component description ............................................................................ 1-8Chassis assembly ...................................................................................... 1-10
Frame .................................................................................................. 1-10Carriage .............................................................................................. 1-10Drive foot assemblies ......................................................................... 1-12
TW-102 Hydraulic Torque Wrench assembly .......................................... 1-14Soft clamp feature .............................................................................. 1-14
SSW-50 Spinning Wrench assembly ........................................................ 1-16Electrical control system ........................................................................... 1-18
Power distribution .............................................................................. 1-18Systems with optional purge systems............................................1-19
PLC assembly and enclosure ............................................................. 1-21Siemens PLC .................................................................................1-21Central Processing Unit (CPU) microprocessor ............................1-21CPU Random Access Memory (RAM) .........................................1-21Erasable Programmable Read-Only Memory (EPROM) slot .......1-22Backup battery...............................................................................1-22Input/Output (I/O) interface...........................................................1-23PLC power supply .........................................................................1-23Digital I/O module.........................................................................1-23Solenoid drivers.............................................................................1-23Power supply (encoder) .................................................................1-25IS isolation amplifiers and Zener barriers .....................................1-25Expo PLC purge air system (optional) ..........................................1-25
Position and proximity sensors/switches ........................................... 1-26 Hydraulic system ..................................................................................... 1-30
Hydraulic manifold assembly ............................................................ 1-30Pressure-reducing Valve (PRV) ......................................................... 1-30Lift cylinder circuit ............................................................................ 1-31Linear position slave cylinder assembly ............................................ 1-31Horizontal travel circuit ..................................................................... 1-31Spinning wrench clamp circuit ........................................................... 1-31
1-4 AR3200 SM00053, Rev D
July 1, 2005
Spinning wrench spin circuit .............................................................. 1-31Tilt cylinder circuit ............................................................................. 1-32Torque wrench clamp circuit .............................................................. 1-32Torque cylinders makeup and breakout circuit .................................. 1-33NFPA 496 Type Y roughneck J-box purge system
(UL only) .......................................................................... 1-33Internal Blow Out Preventer (IBOP) hanger kit (optional) ................ 1-33
Specifications .................................................................................................. 1-34Other specifications .................................................................................. 1-37
Drive rails/adapter plates ...............................................................1-37Spinning wrench (pipe spinner).....................................................1-37Torque wrench ...............................................................................1-38Horizontal movement ....................................................................1-38Vertical movement.........................................................................1-38Tilt movement................................................................................1-39
Main materials of construction (type and grade) ...................................... 1-40Cylinders........................................................................................1-40Hydraulic hose ...............................................................................1-41
Description 1-5
Chapter 1
Description
General descriptionThe AR3200 Automated Roughneck (sometimes referred to as the “Roughneck”) allows one operator to make up or break out drill string connections automatically. The AR3200 uses a Programmable Logic Controller (PLC), PLC software, sensors, and solenoid-actuated hydraulic valves to operate the unit through a makeup or breakout sequence.
The base control system allows the operator to initiate tool function sequences that automatically position the torque wrench at the tool joint and make up or break out the joint.
Makeup modeIn the makeup mode, the sequence of functions stops before applying makeup torque (allowing the tool to be used as a stabbing guide), stops again while makeup torque is applied (allowing the operator/driller to verify correct torque), and returns to the Home position with a single operator action.
1-6 AR3200 SM00053, Rev D
July 1, 2005
Breakout modeIn the breakout mode, the unit executes a full sequence and returns to the Home position with a single operator action.
Operator controlsOperator controls allow for horizontal and vertical positioning, breakout/spin, spin/torque and mousehole tilt (up to 7°), using electrohydraulic controls.
MANUAL CONTROL STATION
The Manual Control Station can be on either the right or left side of the unit and contains all switches that control AR3200 functions individually. (For detailed information see the Operation chapter.)
Operating in manual mode
By using manual mode switches you can interrupt any automatic sequence in progress and initiate the manual function.
z Normally, the AR3200 operates at a setting of 2,000 psi. When set to 2,500 psi, the AR3200 must be operated manually. Integrated sensors and interlocks enable the AR3200 to perform several functions sequentially without operator intervention. Interlocks also prevent the operator from inadvertently initiating inappropriate operating sequences.
When the AR3200 is operating in manual mode, only the end-of stroke interlock is in effect. The other interlocks do not function.
For drill collars or special operations, you can switch to manual mode at a setting of 2,500 psi.
AUTOMATIC CONTROL STATION
The Automatic Control Station is located either beside the Manual Control Station (UL) or on the Manual Control Station panel (EEx). (For detailed information see the Operation chapter.)
EMERGENCY STOP
You can stop tool operation at any time by using the EMERGENCY STOP pushbutton located on the manual control station or the remote monitor station. You also can set the tool to operate in OVERRIDE mode.
SM00053, Rev D Description 1-7
Operator controls
TOOL J-BOX CONTROLS
The tool J-box holds a two-switch panel for selecting the tool joint length and power slip mode. The top switch selects either manual mode or a preset tool joint length for 8, 10, 12., 14., or heavy weight (HW) tool joints. With a preset tool joint length, the AR3200 finds the tool joint automatically.
The lower switch selects the power slip mode: ON (when using a power slip) or OFF. When set to ON, the AR3200 adjusts its carriage height to clear a power slip.
See the Operation chapter for the control panel layout.
1-8 AR3200 SM00053, Rev D
July 1, 2005
Major component descriptionThe AR3200 consists of the following basic assemblies:
❏ Chassis assembly (page 1-10)
❏ TW-102 Hydraulic Torque Wrench (page 1-14)
❏ SSW-50 Spinning Wrench (page 1-16)
❏ Electrical control system (page 1-18)
❏ Hydraulic system (page 1-30)
❏ NFPA tool J-box purge system (UL configurations, page 1-33)
Figure 1- 1 shows the general arrangement of the AR3200 in relation to the derrick. Figure 1-2 shows the general arrangement of the AR3200.
SM00053, Rev D Description 1-9
Major component description
CIRCUITS
SAFE
INTRINSICALLY
To Remote Controller
Mounting Plate
Drill Floor
C WellL
AR3200AutomatedRoughneck
HydraulicService Loop
ElectricalService Loops
Derrick
Derrick Plate
Service Loop Bracket
RemoteController (PLC)
AC Regulator
Figure 1- 1. Typical AR3200 General arrangement
1-10 AR3200 SM00053, Rev D
July1, 2005
Chassis assemblyThe primary AR3200 chassis assembly components include the frame, carriage and drive feet.
FRAME
The frame consists of two uprights connected by a removable strong back and a cross beam at the top. Two hydraulic motor-driven feet support the frame at the base. The motors in the feet propel the AR3200 from the standby, or Home, position to well center and back. The feet mount on rails welded to the rig floor on opposite sides of the well bore and across the rotary table.
CARRIAGE
The carriage assembly is located between the two uprights of the frame, supported by vertical guides, rollers, and two hydraulic vertical lift cylinders. The carriage supports a torque wrench and Spinning Wrench. Two vertical lift cylinders move the carriage up and down to position the torque wrench jaws above and below the pipe joint.
The carriage can tilt up to 7° to match the angle of the pipe in a mousehole. An optional reverse tilt feature allows the AR3200 to reach a mousehole installed between the rotary table and the drawworks.
A wear plate, mounted under the carriage, supports and positions the tool joint sensor
SM00053, Rev D Description 1-11
Major component description
HWMAN
8"
10" 12"
14"
PS-16
OFF ON
TJ LENGTH
Lower TorqueWrench Jaw
Upper TorqueWrench Jaw TW-102
Torque WrenchAssembly
ControlStation
MotorDrivenFoot (2)
HydraulicHorizontalDrives (2)
FrameAssembly
Uprights(2)
SSW-50Spinning WrenchAssembly
ClampRollers (2)
PressureRollers (2)
HydraulicRoller Drives (4)
Stabbing Guide
Tool Electrical J-Box Carriage LiftCylinders (2)
Figure 1-2. Typical AR3200 Automated Iron Roughneck
1-12 AR3200 SM00053, Rev D
July 1, 2005
DRIVE FOOT ASSEMBLIES
Two motor-driven feet on either side of the AR3200 chassis support the AR3200 (Figure 1-3). The feet move on cogged drive rails, allowing the tool to travel to and from well center and the Home position. The right foot contains a horizontal index sensor. (See the Maintenance chapter for adjustment procedures.)
The left foot contains a horizontal position sensor and a J-box routed to the horizontal position sensor. The gearbox cover of each drive foot faces the inside of the roughneck, while the motor access covers face the outside. Both drive feet include the following:
❏ An idler roller located at the front of each foot
❏ A cogged drive roller located at the rear of each foot
❏ A hydraulic motor
❏ A gearbox
❏ A motor access cover
❏ A gearbox cover
SM00053, Rev D Description 1-13
Major component description
Gearbox
Gearbox Cover
Idler Roller
Hydraulic Motor
Cogged Drive Roller
Foot Assy.
Motor Access Cover
Foot Access Cover
Figure 1-3. Typical AR3200 drive foot
1-14 AR3200 SM00053, Rev D
July 1, 2005
TW-102 Hydraulic Torque Wrench assemblyThe TW-102 Hydraulic Torque Wrench (Figure 1-4) is an open throat design that eliminates all gates and latches. The torque wrench can make and break connections for 3 1/2 in. drill pipe to 9 3/4 in. drill collars and provides up to 100,000 ft-lb of makeup torque and 120,000 ft-lb of breakout torque.
The torque wrench consists of two gateless, upper and lower clamping jaws. A 9 in. (229 mm) hydraulic cylinder located at the back of each jaw provides sufficient clamping force to apply torque without distorting the box and pin, nor allowing the gripping dies to slip.
Two hydraulic cylinders mount to the sides of the upper wrench, enabling the upper jaw to partially rotate up to 28° during make up or break out.
Bolted to each clamping jaw are gripping dies. Each gripping die consists of a special tong die and die retainer. The die retainers and the tong dies are easily removable. You must change the tong dies and die retainers when changing pipe size. For details on changing the dies, see the Operation chapter.
SOFT CLAMP FEATURE
When set to backup mode, only the lower jaw clamps during spinning operation. This feature is also known as a soft clamp.
SM00053, Rev D Description 1-15
Major component description
Upper JawClamp Cylinder
Upper JawTorque Cylinder
Tong Diesand Retainer
Figure 1-4. Hydraulic Torque Wrench Assembly
1-16 AR3200 SM00053, Rev D
July 1, 2005
SSW-50 Spinning Wrench assemblyThe SSW-50 Spinning Wrench (Figure 1-5) spins tubulars from 3 1/2 to 9 3/4 in. in diameter without requiring manual size adjustment. A “floating” mount design compensates for minor pipe misalignment. The roller arms open sufficiently to pass 18 in. diameter drilling stabilizers. The spinner rotates 5 in. diameter pipe at up to 150 rpm and produces up to 2,000 ft-lb of rotational torque.
Table 1-1 describes the operational modes of the Spinning Wrench assembly.
For more information on the operating modes, see the Operation chapter.
The Spinning Wrench contains four drive rollers: two pressure rollers and two clamping rollers. Four hydraulic motors drive one each of the four rollers. Hydraulic flow dividers supply fluid to the four motors to ensure positive spinning force without the need for a complicated transmission. This system transfers power to the drill pipe and collars more efficiently, increasing the spinning torque by 50%, while requiring 50% less clamping force on a tubular.
Table 1-1. Spinning Wrench operational modes
Mode Description Function
Normal Pressure mode switched to the 2,000 psi position
The spinner rotates at full speed for drill pipe.
Drill Collar Pressure mode switched to the 2,500 psi position
The spinner rotates at reduced speed for “walking in” large drill collars.
SM00053, Rev D Description 1-17
Major component description
HydraulicMotors (4)
ClampingRollers (2)
PressureRollers (2)
ClampCylinder (2)
Figure 1-5. SSW-50 Spinning Wrench assembly
1-18 AR3200 SM00053, Rev D
July 1, 2005
Electrical control systemThe electrical control system (Figure 1-6 and Figure 1-7) includes a Programmable Logic Controller (PLC) assembly, PLC software, sensors, and electrically actuated solenoids. The solenoids control hydraulic valves for operating the unit during makeup and breakout sequences. The electrical control system also includes a manual control station, which allows you to manually initiate Roughneck functions.
PLC programming directs all normal makeup and breakout functions. An operator can perform makeup and breakout functions with the AR3200 manually-one function at a time, or automatically with a single operator action.
The automatic and manual controls are located on either the left or right side of the tool, depending on the configuration purchased. (See the Operation chapter for details on the automatic and manual controls.
POWER DISTRIBUTION
Input power for the AR3200 can range from 90 to 520 VAC, single phase at 50/60 Hz. Input power first enters an AC voltage regulator. The AC voltage regulator converts the input power to 115 VAC, single phase, 50/60 Hz and must be mounted in a nonhazardous area. The voltage regulator outputs the 115 VAC to the following circuit breakers:
❏ 1-amp and 5-amp circuit breakers on standard configurations with no optional purge systems
❏ 1-amp and 5-amp circuit breakers on EEx configurations with an optional PLC purge system, through a purge loss-of-pressure switch
❏ 1-amp and 5-amp circuit breakers on UL configurations with AR3200 tool J-box and optional PLC purge systems, through the PLC purge loss-of-pressure switch and isolation relay (controlled by the AR3200 tool J-box loss of pressure switch)
❏ 1-amp and 5-amp circuit breakers on UL configurations with the AR3200 tool J-box purge system, through a purge loss-of-pressure switch
SM00053, Rev D Description 1-19
Major component description
Systems with optional purge systems
Purge loss-of-pressure-switch contacts close when the required minimum purge pressure is reached. purge loss-of-pressure switch contacts open when the purge pressure falls below the minimum requirement.
Two 1-amp circuit breakers connect to the 24 and 12-volt DC power supplies located inside the PLC assembly enclosure.
Two 5-amp circuit breakers connect to the AR3200 solenoids via a kill relay and solenoid drivers. The kill relay is part of the ESD circuit. In normal operation, the kill relay is activated and the ESD circuit is closed. When the ESD circuit is open, the kill relay prevents the 115 VAC required by the solenoids from passing through the solenoid drivers.
Manual Controls
AR3200
SolenoidOperated
DCV
PLCAssembly
ToolJ-Box
Service Loops (3)
VoltageRegulator
RemoteMonitorStation
OptionalDriller'sControl
Sensors
Figure 1-6. Typical AR3200 electrical control system
1-20 AR3200 SM00053, Rev D
July 1, 2005
Manual Controls
AR3200
SolenoidOperated
DCV
PLCAssembly
ToolJ-Box
Service Loops (3)
PurgePurge Lossof Pressure Switch
VoltageRegulator
RemoteMonitorStation
Sensors
Figure 1-7. Typical AR3200 electrical control system with PLC purge
SM00053, Rev D Description 1-21
Major component description
PLC ASSEMBLY AND ENCLOSURE
The AR3200 PLC assembly is located in an enclosure remotely located from the tool. The primary PLC assembly components include the following items, as shown on Figure 1-8 on page 1-24:
❏ Siemens S5-95U PLC (page 1-21)
• Central Processing Unit (CPU) microprocessor (1-21)
• CPU Random Access Memory (RAM) (1-21)
• Erasable Programmable Read-Only Memory (EPROM) receptacle (slot) (page 1-22)
• Digital input/output (I/O) module (page 1-23)
• PLC power supply (1-23)
❏ Backup battery (page 1-22)
❏ Solenoid drivers (page 1-23)
❏ Power supplies (page 1-25)
❏ Intrinsically Safe (IS) and Zener barriers (page 1-25)
❏ Expo PLC purge air system (optional) (page 1-25)
Siemens PLC
The Siemens S5-95U PLC consists of the following main components:
Central Processing Unit (CPU) microprocessor
The CPU microprocessor processes all data provided by AR3200 control system components.
CPU Random Access Memory (RAM)
The RAM temporarily stores the data that the CPU microprocessor uses.
z RAM requires electrical power to retain data. If power to the PLC is interrupted, all data in the RAM is lost. (See Backup battery on page 1-22.)
1-22 AR3200 SM00053, Rev D
July 1, 2005
Erasable Programmable Read-Only Memory (EPROM) slot
The Varco-supplied software is stored in a 32-kilobyte Erasable Programmable Read-Only Memory (EPROM). The EPROM receptacle provides an interface between the EPROM and the CPU.
The CPU copies (loads) the Varco software from the EPROM to the RAM for actual use by the microprocessor.
z The memory in the EPROM is nonvolatile; i.e., it does not require power to keep the software in its memory. As it is read-only memory, the software in the EPROM cannot be accidentally changed.
Backup battery
The PLC lithium backup battery continues to supply power to prevent loss of data stored in the RAM if the regular power supply to the CPU is interrupted.
z All data in the RAM is lost if power interruptions last long enough to completely discharge the backup battery. Under normal operating conditions, the lithium backup battery supplied with the AR3200 PLC should last approximately one year. Replace batteries older than one year with new lithium batteries to prevent data loss.
SM00053, Rev D Description 1-23
Major component description
Input/Output (I/O) interface
The I/O interface allows the CPU to transfer data to and from external I/O modules. (See Potentiometer driver on page 1-23.)
PLC power supply
The PLC power supply is part of the Siemens PLC assembly. The power supply provides 24 VDC electrical power to the following PLC assembly components:
❏ Siemens PLC
❏ Intrinsically Safe (IS) isolation amplifiers and barriers
❏ Emergency Shutdown (ESD) manual control switches
❏ Potentiometer driver
Digital I/O module
z The digital I/O module allows for additional connections (interfaces) between the CPU and other control system components, such as proximity switches and solenoid drivers.)
Solenoid drivers
The solenoid drivers in the PLC assembly are solid state relays. The drivers switch 115 VAC power to actuate the solenoids that direct hydraulic valves on the AR3200. The CPU determines when to actuate a particular solenoid.
1-24 AR3200 SM00053, Rev D
July 1, 2005
12
34
56
78
998
76
54
32
1
1
1
1
1
1
1
1
1
1
8
7
6
5
4
3
2
11
2
3
4
5
6
7
8
TB 7
715
764
A
B
C
D
4
5
TB 1
3
2
1
0
61
51
41
12
31
11
01
9
8
7
6
71
81
91
2
3
5
4
3
0
1
2
6
21
22
2 3
2 4
2 5
2 6
2 7
2 8
2 9
3
3
3
3
3
3
2
19
18
17
6
7
8
9
10
11
13
21
14
15
16
5
4
3
2
1
0
6
2
2
1
0
3
4
5
3
1
2 2
2 3
2 4
2 5
2 6
2 7
2 8
2 9
3
3
3
3
3
3
1
2
3
4
5
6
7
8
0
9
1
8
7
6
5
4
3
2
1
9
01
TB 3
1
2
3
4
5
6
7
8
9
0
11
2
3
4
5
6
7
32
22
12
02
9
8
42
8
7
6
5
4
3
2
1
1
9
0
11
1 2
1 3
1 4
1 5
1 6
71
32
22
12
02
19
81
2 4
TB 2TB 4
TB 5
1
9
0
8
7
6
5
4
3
2
1
10
9
1
2
3
4
5
6
7
8
1 8
91
2 0
2 1
2 2
1 7
61
51
41
31
21
11
01
9
8
7
6
5
4
3
2
1
1 8
91
2 0
2 1
2 2
1 7
61
51
41
31
21
11
0
9
1
1
2
3
4
5
6
7
8
TB 9
4
3
2
1
4
3
2
1
1
2
3
4
5
6 6
5
4
3
2
1
TB 6
5
6
7
88
7
6
5 1
1
5
5
MODULE D
98
76
54
32
1 12
34
56
78
9
MODULE C
12
34
56
78
9 98
76
54
32
11
23
45
67
899
87
65
43
21
MODULE A
MODULE B
SPARE
TEACH
OFF ON
ONOFF
TB 8
121114
42 12 22
A2A2A1
321 4
1 2 3 4
24V Power Supply Backup Battery CPU EPROM I/O Module PLC Box Assy
SolenoidDrivers
Kill Relay(ESD)
SolenoidDrivers
1AMPCircuitBreakers
5 AMPCircuit Breakers
Isolation Relay(BEBCO UL Purgeon Tool J-Box)
EncoderSafetyBarrier
ISPotentiometerDriver
12V PowerSupply(Encoder)
IS Terminal Blocks(Knife Switch Type)
Learn Mode Switch
ISAmplifier/Barrier
Figure 1-8. AR3200 PLC assembly and enclosure
SM00053, Rev D Description 1-25
Major component description
Power supply (encoder)
A 12-volt power supply (encoder) is located in the PLC assembly enclosure and provides electrical power for the optical encoder. (For more information on the optical encoder, see Table 1-2, Sensor functions, on page 1-27.)
IS isolation amplifiers and Zener barriers
The AR3200 PLC uses IS isolation amplifiers and Zener barriers for the sensors and the optical encoder to provide required protection against an explosion in hazardous areas. This method of protection limits the energy in devices located in hazardous areas.
In the event a fault results in either excessive voltage or current, an internal fuse ruptures, preventing unsafe energy levels in the hazardous area.
Expo PLC purge air system (optional)
The optional Expo PLC purge system mounts on the PLC assembly enclosure. The PLC purge system allows locating the PLC assembly enclosure in Zone 2 (European) or Division 2 (NEC) hazardous areas.
The purge system uses clean, dry pressurized air plumbed into the PLC assembly enclosure to prevent accumulation of flammable or explosive fumes inside the enclosure. The system also eliminates heat, moisture and dust contamination within the PLC assembly enclosure.
A purge pressure switch monitors the purge system and detects a loss of purge air supply pressure in the PLC enclosure.
1-26 AR3200 SM00053, Rev D
July 1, 2005
POSITION AND PROXIMITY SENSORS/SWITCHES
The AR3200 contains the following sensors:
❏ Five proximity sensors
❏ One vertical position encoder
❏ One flow sensor
❏ One spinout (proximity) sensor
Proximity sensors (Figure 1-9) monitor equipment functions. These sensors detect the presence or absence of metal. AR3200 proximity sensors sense the presence or absence of a metal target located on various moving components. The PLC uses input from theses sensors to help direct operating sequences.
Figure 1-10 and Figure 1-11 indicate the locations of the proximity sensors on the AR3200. The sensors function as shown in Table 1-2.
Figure 1-9. Typical proximity sensor
SM00053, Rev D Description 1-27
Major component description
Table 1-2. Sensor functions
Sensor Function
Torque wrench position sensor Enables the PLC to direct positioning of the torque wrench bodies before performing a makeup or breakout sequence. It also allows the PLC to determine when a restroke is required during a makeup sequence. This sensor is on the left side of the torque wrench body.
Tool joint detector sensor Detects the upset of the drill pipe joint when it senses the absence of metal as it vertically scans.
End-of-stroke sensor Prevents bending the carriage when the slips are not holding the pipe tightly enough. Detects when the carriage is approximately 3/4 in. (19 mm) from its lowest position. This sensor also functions as a vertical index sensor, providing a fixed point of reference in determining the absolute carriage position.
Horizontal position sensor Provides the PLC with input to determine the AR3200 position on its track relative to an index cutout in the cogged drive rails. (See the Installation and Operation chapters for details on the cogged drive rails and indexing.) This sensor allows the PLC to count the number of drive rail cogs detected relative to the index cutout when the tool moves back and forth.
Horizontal index sensor Resets the horizontal position count in the PLC when the AR3200 moves over the index cutout in the cogged drive rails. It provides a fixed point of reference in determining the absolute horizontal posi-tion of the tool.
Vertical position optical encoder
This incremental optical encoder, measures the carriage height of the torque wrench jaws relative to the pipe joint.
Flow sensor Monitors hydraulic return flow and signals the PLC when the fol-lowing conditions exist:
• The torque wrench jaws are fully opened, closed, or clamped.
• The torque wrench body is in the full makeup or breakout position.
• The Spinning Wrench spins pipe in and the joint is shoulder-to shoulder.
• The Spinning Wrench arms are fully open, closed, or clamped.
Spinout sensor Located on the back of the Spinning Wrench in a junction box, this sensor detects spinout activity (bumping) and relays this information to the PLC. This proximity sensor contains a target and spring. Varying the target distance of the proximity sensor inside the sensor J-box adjusts the spinout sensor sensitivity.
1-28 AR3200 SM00053, Rev D
July 1, 2005
HWMAN
8"
10" 12"
14"
PS-16
OFF ON
TJ LENGTH
Spinout Sensor(Behind SSW-50)
Horizontal PositionSensor
Torque WrenchPosition Sensor
Tool Joint Detector
Figure 1-10. AR3200 sensor locations
SM00053, Rev D Description 1-29
Major component description
Flow Switch(Behind Intake Manifold)
EOS Sensor
Horizontal IndexSensor
Vertical Position Encoder
Figure 1-11. AR3200 sensor locations
1-30 AR3200 SM00053, Rev D
July 1, 2005
Hydraulic systemThe AR3200 hydraulic system includes the following components:
❏ Hydraulic manifold assembly (page 1-30)
❏ Pressure-reducing valve (PRV) (page 1-30
❏ Lift cylinder circuit (page 1-31)
❏ Linear position slave cylinder assembly (page 1-31)
❏ Horizontal travel circuit (page 1-31)
❏ Spinning wrench clamp circuit (page 1-31)
❏ Spinning wrench spin circuit (page 1-31)
❏ Tilt cylinder circuit (page 1-32)
❏ Torque wrench clamp circuit (page 1-32)
❏ Torque cylinders make up and breakout circuit (page 1-33)
See the Troubleshooting chapter for additional information on the hydraulic circuit components.
HYDRAULIC MANIFOLD ASSEMBLY
A hydraulic manifold assembly mounts on the AR3200 carriage. The hydraulic manifold assembly consists of electrically actuated solenoids controlling the hydraulic valves that direct all hydraulic functions of the AR3200.
PRESSURE-REDUCING VALVE (PRV)
The pressure-reducing valve (PRV) sets the hydraulic pressure at either 2,000 psi or 2,500 psi (128 - 172 Bar) to spin in and make up drill pipe and drill collars. The AR3200 has 100,000 ft-lb of torque available for makeup and 120,000 ft-lb of torque available for breakout torque.
z The tool applies the full 120,000 ft-lb of torque when breaking out.
The PRV changes pressure by activating a solenoid valve. The operator selects 2,000 psi or 2,500 psi using a switch on the manual control station located on the roughneck.
SM00053, Rev D Description 1-31
Major component description
LIFT CYLINDER CIRCUIT
Hydraulic pressure travels through the directional control valve (DCV) and two flow control valves, allowing lift cylinder speed control.
If the driller starts to lower the string in the hole while drilling with the torque wrench clamped onto the drill pipe, pressure builds up on the rod end of the lift cylinder. When the hydraulic pressure reaches a preset level, the counterbalance valve opens and the carriage lowers.
LINEAR POSITION SLAVE CYLINDER ASSEMBLY
The slave cylinder assembly is located behind the tool carriage, adjacent to the right side lift cylinder. The slave cylinder provides positive drive for the optical encoder, converting the vertical motion of the carriage to the rotary motion of the optical encoder.
The end-of-stroke sensor is located in the slave cylinder assembly. When the end-of-stroke sensor detects that the carriage is within 3/4 in. (19 mm) of reaching bottom, the torque wrench jaws and the Spinning Wrench clamp open solenoids energize, preventing damage to the AR3200.
HORIZONTAL TRAVEL CIRCUIT
The horizontal travel hydraulic circuit moves through directional control valves (DCV) and flow control valves allowing horizontal speed control. As the AR3200 approaches the well center, a deceleration valve (PLC control) automatically reduces the tool’s speed.
SPINNING WRENCH CLAMP CIRCUIT
Hydraulic flow travels through the DCV directly to the clamp cylinders. The Spinning Wrench clamp contains a hydraulic check valve that maintains full clamp force on the Spinning Wrench jaws.
SPINNING WRENCH SPIN CIRCUIT
The Spinning Wrench spin circuit contains four hydraulic motors that can work at two different speeds-fast (at 2,000 psi) and slow (at 2,500 psi). DCVs control the direction and flow dividers ensure that all motors run at an equal speed. The speed adjustment control works in 2,500 psi mode only.
1-32 AR3200 SM00053, Rev D
July 1, 2005
TILT CYLINDER CIRCUIT
Hydraulic flow travels through the DCV to the tilt cylinder. The tilt cylinder circuit contains check and flow control valves. The check valves maintain the cylinder’s position in the event a pressure drop occurs. The flow control valves allow adjustment of the tilting speed.
TORQUE WRENCH CLAMP CIRCUIT
The AR3200 torque wrench clamp circuit has a regenerative circuit to increase operating speed. The regenerative circuit directs hydraulic pressure to the blind end from the rod end, allowing greater flow and increased speed.
The AR3200 torque wrench clamp circuit directs hydraulic pressure out of the B working port of the DCV to the blind end of the torque wrench clamp cylinder. This causes the cylinder to start stroking, causing pressure to build up on the rod side of the cylinder. A check valve allows additional fluid to empty the B Line circuit, allowing greater flow into the blind end of the cylinder. This increases the clamping speed.
The AR3200 soft clamp mode enables the tool to hold the box while spinning in drill pipe. See the Operation chapter for details.
SM00053, Rev D Description 1-33
Major component description
TORQUE CYLINDERS MAKEUP AND BREAKOUT CIRCUIT
The torque wrench makeup/breakout circuit directs hydraulic flow through the DCV directly to the torque cylinders. A pressure reducing valve allows the operator to select the required makeup torque from 5,000 to 100,000 ft-lb. Breakout torque is fixed at 120,000 ft-lb.
NFPA 496 TYPE Y ROUGHNECK J-BOX PURGE SYSTEM (UL ONLY)
The NFPA 496 purge system allows operating the AR3200 in Class 1, Division 1 areas. The purge system uses pressurized air plumbed into the electrical tool J-box located on the roughneck. A purge pressure loss switch monitors the purge system and detects a loss of purge pressure.
INTERNAL BLOW OUT PREVENTER (IBOP) HANGER KIT (OPTIONAL)
The IBOP hanger is an optional feature of the AR3200 and is installed on the AR3200 at the factory when purchased. The IBOP hanger assembly is bolted onto the left side of the carriage and supports and aids in stabbing and connecting an IBOP.
1-34 AR3200 SM00053, Rev D
July 1, 2005
SpecificationsFigure 1-12 and Figure 1-13 provide dimensional information on the AR3200.These illustrations are based on 59" track spacing. For 75" track spacing, see your rig-specific documentation.
SM00053, Rev D Description 1-35
Specifications
59.0
(149
9)R
AIL
SP
AC
ING
70.0
(177
8)
66.0(1676) TW-102
CONTROLS
- FOR 37-1/2" ROTARY TABLE- FOR 49 -1/2" ROTARY TABLE**
*
COG DRIVE TRACK(LENGTH-AS REQUIRED)
127.0(3226)MIN, 175.0(4445)MAX
84.0(2134)MIN, 132.0(3353)MAX
48.0(1219)MIN
48.0(1219)MIN
32.0(813)MIN80.0(2032)MAX
EXPOSED ROTATINGSURFACES COVERED(BY CUSTOMER)
17.0(432)MIN
Mousehole
34.4(874)DIA
HINGEDADAPTERPLATE
89.92(2284)-REF
31.0(787)*38.0(965)**
31.0(787)*38.0(965)**
AlternateMousehole
ALL DIMENSIONS AREFOR REFERENCE ONLY
Figure 1-12. Dimensional data
1-36 AR3200 SM00053, Rev D
July 1, 2005
135.0
28.25
[3429]
SSW Fully Extended
102.0[2591]
[718]
65.4 [1661]60.0 [1290]
Pin/BoxShoulder
RIGHTHAND
LEFTHAND
Well Bore
28.0 [711]3500 LB
[1720 KG] 2500 LB[1228 KG]WHEEL
Foot BottomCL
DrivenWheel
Typical unit weight with accessories is 12,000 lb.The weight of heaviest component to be handled duringmaintenance is Torque Wrench Assembly-3,400 lb.
ALL DIMENSIONS AREFOR REFERENCE ONLY
62.5 [1588]
66.0 [1676]
63.6 [1615]
33.0[838]Stroke
WellBoreCL
31.8 [808]
Figure 1-13. Dimensional data
SM00053, Rev D Description 1-37
Specifications
Other specificationsHydraulic operating pressure required 2,000 - 2,500 psi (138 - 172 Bar)
Hydraulic flow rate required (min.) 45 gpm (170 lpm)
Hydraulic pressure at max. flow 2,500 psi (172 Bar)
PLC purge air pressure required 60 psi (min.) 100 psi (max.)4 Bar (min.) 7 Bar (max.)
UL tool purge air pressure required 5 psi (min.) 120 psi (max.).34 Bar (min.) 8 Bar (max.)
Air flow rate required (max.) 4 SCFM
Drive rails/adapter plates
Adapter plates (hinge to hinge) 70 in. (1778 mm)
Overall rail length 127 in. (3226 mm) (min.)
Width over rails 59 in. (1499 mm) or75 in. (1905 mm)
Rail section (size) 1 in. x 5 in. (25 mm x 127 mm)
Fastening method Welded to rig floor
Spinning wrench (pipe spinner)
Minimum pipe size capacity 3 1/2 in. (drill pipe)
Maximum pipe size capacity 9 3/4 in. (drill collar)
Open jaw width 18 1/2 in. (470 mm)
Number of spinner motors 4 (four)
Gripping force adjustable No
Spinning speed adjustable (5 in. d.p.) 0-150 rpm
Number of driven rollers 4 (four)
Spin-in speed max. (6 5/8 in. d.p.) 100 rpm
Spin-out speed max. (6 5/8 in. d.p.) 100 rpm
Spin-in torque at stall 2,000 ft-lb with 5 in. pipe
Spin-out torque at stall 2,000 ft-lb with 5 in. pipe
1-38 AR3200 SM00053, Rev D
July 1, 2005
Torque wrench
Minimum pipe size capacity 3 1/2 in. (drill pipe)
Maximum pipe size capacity 9 3/4 in. (drill collar)
Makeup torque (maximum) 100,000 ft-lb (135600 N-m)
Breakout torque (fixed) 120,000 ft-lb (162700 N-m)
Torque range adjustable Yes
Gripping force adjustable Yes, with Variable Clamp Force Kit
Degrees of rotation 28°
Length of stroke (torque) 8.5 in. (216 mm)
Length of stroke (clamp) 5.98 in. (152 mm)
Cylinder bore (torque) 5 in. (127 mm)
Cylinder bore (clamp) 9 in. (229 mm)
Requirement for jaw gates No
Horizontal movement
Drive type Hydraulic
Number of drive motors 2 (two)
Number of driven wheels 2 (two)
Speed 1 ft./sec. (.30 m/sec.), nom.
Vertical movement
Drive type Hydraulic
Number of cylinders 2 (two)
Vertical movement 33 in. (838 mm)
Adjustable end stops No
Speed adjustable No
Speed 6 in./sec. (152 mm/sec), nom.
SM00053, Rev D Description 1-39
Specifications
Tilt movement
Drive type Hydraulic
Number of tilt cylinders 2 rev. tilt, 1 forw. tilt
Cylinder bore 2 1/2 in. (64 mm)
Cylinder stroke 7 in. (178 mm)
Maximum tilt angle 7° (rev. & forw. tilt)
Tilt angle adjustable Yes (Forward only)
1-40 AR3200 SM00053, Rev D
July 1, 2005
Main materials of construction (type and grade)Main body MS 00001 Grade 150-135
Torque wrench die holders 4130 Steel
Torque wrench die 86 L20 Steel
Spinner rollers 4140 Steel
Cylinders
Body ASTM A36 Steel
Piston ASTM A36 Steel
Rod 17-4 PH
Seals BUNA-N
Guide rails M1020 Steel
Wheels 86 L20 Steel
Adapter plate A36 Steel (Diamond Patt.)
Hydraulic tube Cadmium-plated steel
Hydraulic tube/hose fittings Cadmium-plated steel
SM00053, Rev D Description 1-41
Specifications
Hydraulic hose
Specification/type 100R2
SizePressure rating
Burst pressure
Fire resistance
Material
3/8 in. 5,000 16,000 Yes Rubber/Wirebraid
1/2 in. 4,250 14,000 Yes Rubber/Wirebraid
3/4 in. 3,000 9,000 Yes Rubber/Wirebraid
1 in. 2,500 8,000 Yes Rubber/Wirebraid
Specification/type 100R9
SizePressure rating
Burst pressure
Fire resistance
Material
3/8 in. 4,500 18,000 Yes Rubber/Wirebraid
1/2 in. 4,000 16,000 Yes Rubber/Wirebraid
3/4 in. 3,000 12,000 Yes Rubber/Wirebraid
1 in. 3,000 12,000 Yes Rubber/Wirebraid
1-42 AR3200 SM00053, Rev D
July 1, 2005
AR3200
AutomatedRoughneck
Installation
July 1, 2005
2-2 AR3200 SM00053, Rev D
Installation 2-3
Chapter 2 Contents
Chapter 2 Installation
Unpacking and handling procedure ................................................................... 2-5Short and long term storage ........................................................................................ 2-6
Initial inspection ................................................................................................ 2-6Preinstallation requirements .............................................................................. 2-7
General requirements .................................................................................. 2-7Electrical requirements ............................................................................... 2-7Hydraulic requirements .............................................................................. 2-7Pneumatic requirements .............................................................................. 2-8UL tool J-box purge system requirements .................................................. 2-8PLC purge system requirements ................................................................. 2-8Special tools and support equipment .......................................................... 2-8
Installation procedures ...................................................................................... 2-9Referenced drawings .................................................................................. 2-9Component installation ............................................................................. 2-10
Installing the AR3200 adapter plate ................................................... 2-10Installing the AR3200 rails ................................................................ 2-11Installing the AR3200 assembly ........................................................ 2-12Installing the derrick J-box mounting plate and hydraulic derrick plate assembly ........................................................................ 2-14
Derrick J-box mounting plate ...................................................... 2-14Hydraulic derrick plate assembly ................................................ 2-14
Installing the hydraulic pressure transducer ....................................... 2-17Installing the hydraulic torque gauge ................................................. 2-18Installing the hydraulic service loop .................................................. 2-19Interconnecting purge air (UL configurations) .................................. 2-20Installing the monitor and optional control stations ........................... 2-21
Control station options ................................................................. 2-21Installing the AC voltage regulator .................................................... 2-23
Nonpurged installation ................................................................ 2-23UL and EEx installation .............................................................. 2-23General notes ............................................................................... 2-23
Installing the PLC enclosure (nonpurged) ......................................... 2-24Installing the optional PLC enclosure purge unit ............................... 2-24Installing the electrical service loop ................................................... 2-25
2-4 AR3200 SM00053, Rev D
July 1, 2005
Installation 2-5
Chapter 2
Installation
Unpacking and handling procedureTo unpack the AR3200:
1. Remove crate from component or part.
z The roughneck assembly is shipped on its back.
2. Unwrap protective covering from component or part.
3. Remove tape from machined and/or gasket surface.
4. Remove any remaining adhesive using a clean cloth and solvent.
5. Clean component or part of any nonessential oil or grease used as a protective coating for shipment or storage.
6. Remove protective caps from electrical and hydraulic connectors.
2-6 AR3200 SM00053, Rev D
July 1, 2005
Short and long term storageSee Pipehandling Systems Preshipment Preparation Short & Long Term Storage, QA 00016 in the Supplemental Materials chapter.
Initial inspectionFor initial inspection, use the following drawings in the Drawings chapter:
❏ AR3200 Installation - 59" (or 75") Track Spacing drawing
❏ AR3200 Electrical Installation Kit drawing
❏ Also use the packing list.
After unpacking components and parts, inspect as follows:
1. Inventory all components and parts. In case of missing or incorrect parts, notify Varco.
2. Inspect all components and parts for shipment damage and corrosion. If damage to a component or part occurred during shipment, notify the carrier. If corrosion beyond reasonable limits is present, notify Varco.
SM00053, Rev D Installation 2-7
Preinstallation requirements
Preinstallation requirements
e Be sure to satisfy all electrical and hydraulic requirements before installing the AR3200. UL installations with an AR3200 J-box purge system, AR3200s with an optional PLC purge system, and casing AR3200s also have pneumatic requirements.
General requirementsBefore installing the AR3200, be sure to satisfy the following requirements:
❏ The rig floor must be capable of supporting the weight of the AR3200 [approximately 12,000 lb (5,896 kg.)].
n When using rig tongs, the AR3200 home (standby) position must be located far enough away from well center to clear the tongs and prevent equipment collisions. Otherwise, use snub lines on the tongs to ensure tool clearance.
Electrical requirementsThe AR3200 requires an electric supply of 95 to 520 VAC at 15 amps, 50/60 Hz single phase. (For detailed information, see the electrical installation drawings in the Drawings chapter.)
z Installation of an AC regulator for the AR3200 is required.
Hydraulic requirementsThe AR3200 requires a closed-center hydraulic power supply capable of providing at least 45 gpm (170 lpm) at 2,500 psi (172 Bar). When using an open-center hydraulic power supply, use a converter. Varco offers an optional open-to-closed center converter.
2-8 AR3200 SM00053, Rev D
July 1, 2005
Pneumatic requirementsThe following configurations of the AR3200 require a clean, dry, pressurized air supply:
❏ UL configuration with a purge system on the AR3200 tool J-box (
❏ All configurations with a purge system on the PLC
❏ All casing configurations
UL tool J-box purge system requirementsThe UL configuration with tool J-box purge system (API Class I, Division I) requires the following:
❏ 80-120 psi (550-830KPa) at 2.21 SCFM/cu. ft. (60 L/Min.) depending upon the rate of leakage.
PLC purge system requirementsThe PLC purge system (API Class I, Division II or European Standard Zone 2 Area) requires the following:
❏ a minimum of 60 psi (4 Bar) and a maximum of 100 psi (7 Bar) at 4 SCFM.
Special tools and support equipmentTable 2-1 lists special tools and support equipment required for the AR3200.
Table 2-1. Special tools and support equipment
Description Supplier & Model No. Accuracy Range
Multimeter Various <1% FS N/A
Hydraulic Pressure Test Gauge
Various 3-5% FS 0-3000 psi
(0-206 Bar)
*Pneumatic Pressure Test Gauge
Various 3-5% FS 0-150 psi
(0-10 Bar)
*Only required on UL installations with purge system on the roughneck, any configuration with a purge system on the PLC, and casing roughneck configurations.
SM00053, Rev D Installation 2-9
Preinstallation requirements
Installation proceduresTo install the AR3200 components and parts, use the referenced drawings in the Drawings chapter.
Referenced drawings❏ AR3200 Installation - 59" (or 75" ) Track Spacing
❏ AR3200 Hydraulic Service Loop Assembly
❏ AR3200 Electrical Assembly
❏ AR3200 Electrical Installation Kit
❏ AR3200 Automated Iron Roughneck Assembly
❏ AR3200 Interconnect Diagram
❏ AR3200 Remote Controller Assembly (PLC)
❏ AR3200 Derrick Plate Assembly
❏ Rig Floor - 59 " Outside Rail Spacing Kit
❏ Hinged Cog Drive Adapter Plate
2-10 AR3200 SM00053, Rev D
July 1, 2005
Component installationInstalling the AR3200 involves installing the following components:
❏ AR3200 adapter plate (page 2-10)
❏ Rails (page 2-11)
❏ AR3200 assembly (page 2-12)
❏ Derrick J-box mounting plate and hydraulic derrick plate assembly (page 2-14)
❏ Hydraulic torque gauge (page 2-17)
❏ Hydraulic torque gauge (page 2-18)
❏ Hydraulic service loop (page 2-19)
❏ Monitor and optional control stations (page 2-21)
❏ AC voltage regulator (page 2-23)
❏ PLC enclosure, nonpurged (page 2-24)
❏ Optional PLC purge unit (page 2-24)
INSTALLING THE AR3200 ADAPTER PLATE
See the following drawings in the Drawings chapter:
❏ Hinged Cog Drive Adapter Plate
❏ AR3200 Installation - 59" (or 75") Track Spacing
The adapter plate places rails on opposite sides of the well bore and across the rotary table, allowing the AR3200 to travel between home, well center, and the mousehole. The length of the rails varies, based on the desired home position and the position of the mousehole.
Install rails and a hinged two-piece adapter plate to the rig floor so the AR3200 drive rails can clear the rotary table. See the drawings for adapter plate installation specifications and details.
SM00053, Rev D Installation 2-11
Preinstallation requirements
INSTALLING THE AR3200 RAILS
See the following drawings in the Drawings chapter:
❏ Rig Floor - 59" (or 75") Outside Rail Spacing Kit
❏ AR3200 Installation - 59" (or 75") Track Spacing
The feet of the AR3200 mount on cog drive rails welded to the rig floor. Use continuous shims to elevate the cog drive rails so they are level with the rails of the adapter plate. Use a gauge (see the Rig Floor - 59 " Outside Rail Spacing Kit drawing) to mount the cog drive rails. Locate the forward and aft rail stops as specified on the AR3200 Installation - 59" Track Spacing.
The AR3200 requires an index slot to be cut into the cog drive rail so the automatic control system recognizes the tool position relative to the index slot. Cut an index slot in the right cog drive rail as shown on the drawing.
z Rig configurations with removable track or those that require the AR3200 to travel more than 197 ft (60046 mm) from the well center may require an alternate index slot configuration and/or software enhancements.
2-12 AR3200 SM00053, Rev D
July 1, 2005
INSTALLING THE AR3200 ASSEMBLY
See the following drawings in the Drawings chapter:
❏ Automated Iron Roughneck Assembly drawing for steps 1 through 5.
❏ Installation - 59" (or 75") Track Spacing drawing for step 6.
To install the AR3200 Assembly (Figure 2-1):
1. Lift the AR3200 assembly and place it on the installed cog drive rails. Make sure the wheel cogs align with rail notches.
2. Remove the wire rope sling.
3. Remove the shackles.
4. Remove the shipping strap.
5. Remove the shipping bar.
6. Attach lock brackets to the AR3200 drive feet with bolts.
Verify adequate clearance between bracket and rail to permit the tool to travel.
SM00053, Rev D Installation 2-13
Preinstallation requirements
Figure 2-1. AR 3200 t yp ical installation
AR3200 AutomatedIron Roughneck
Track
Hydraulic ServiceLoop
HydraulicService Loop
Mounting Bracket
18' or 30'Mounting
Height
Hydraulic Mounting Plate
Derrick Plate(With J-Box)
ElectricalService Loops
PLC Box Mounting Plate(Plate supplied by others)
AC Regulator
Rig Air for Purge
To ACPower Source
Safe Area
(Mount in Derrick)
Rotary TableAdapter PLates
WellCenter
(Optional)ControlStation
(At Drillers'sConsole)
MonitorStation
2-14 AR3200 SM00053, Rev D
July 1, 2005
INSTALLING THE DERRICK J-BOX MOUNTING PLATE AND HYDRAULIC DERRICK PLATE ASSEMBLY
n Ground all J-boxes (i.e., PLC J-box and derrick J-box). Varco-supplied J-boxes have 10mm grounding studs. Attach one end of a ground strap (customer supplied) to the J-box grounding stud and attach the other end to rig earth.
Derrick J-box mounting plate
A derrick J-box is required to interconnect the AR3200 electrical service loops to the PLC enclosure with derrick wiring (Figure 2-2).
See the following drawings in the Drawings chapter for instructions on mounting the derrick J-box mounting plate to the assembly:
❏ AR3200 Installation - 59" (or 75") Track Spacing
The mounting height depends on the length of the service loop and rig arrangement. The plate contains lifting holes and mounting holes. A bracket securely supports the service loop ends. Service loop pigtails terminate in the derrick J-box (mounted on the plate) through glands in the bottom of the J-box. Make rig connections through the side plates. Use the supplied clamp brackets to secure the rig wiring to the derrick plate.
Hydraulic derrick plate assembly
See the following drawings in the Drawings chapter:
❏ AR3200 Installation - 59" (or 75") Track Spacing
❏ AR3200 Electrical Installation Kit
See Figure 2-2, Hydraulic Derrick Plate, for identification of main components.
The hydraulic derrick plate assembly provides connections for the following:
❏ Pneumatic supply for UL installations and casing roughnecks
❏ Hydraulic supply
❏ Hydraulic return
❏ Hydraulic torque gauge option or Hydraulic pressure transducer option
SM00053, Rev D Installation 2-15
Preinstallation requirements
TorqueGaugeOption
J-Box
1/4" NPT
1/2" NPT1" NPT
1 1/4" NPT
Torque Gauge
PressureTransducer
Option
J-Box
1/4" NPT
1/2" NPT1" NPT
1 1/4" NPT
Pressure Transducer
Figure 2-2. Hydraulic Derrick Plate
2-16 AR3200 SM00053, Rev D
July 1, 2005
The hydraulic derrick plate assembly also provides a place to mount a power J-box for UL configurations with an AR3200 J-box purge system.
Mount the plate on the derrick 30 ft (9144 mm) above the rig floor (when using the standard 37 ft [11278 mm] service loop) and no more than 220 in. (5588 mm) away from well center (Table 2-2).
z
z For UL installations with a purge system on the tool, plumb the rig purge air supply into the 1/2 in. bulkhead fitting on the derrick mounting plate.
Table 2-2. Service loop table
Service Loop Configuration
Loop Length Loop Mounting Height
Recommended Maximum Travel
Standard 37 ft + 1 ft (11278 mm)
30 ft + 1 ft(9144 mm)
18 ft(5486 mm)
Option 25 ft + 1 ft(7620 mm)
18 ft + 1 ft(5486 mm)
13 ft (3962 mm)
Table 2-3. Thread size table
Thread size Service Description
1/4 in. NPT Hydraulic Torque Gauge option
or
Hydraulic Pressure Transducer option
1/2 in. NPT Pneumatic Instrument, Quality Air/Purge System
1 in. NPT Hydraulic Power Supply (Pressure)
1 1/4 in. NPT Hydraulic Power Supply (Return)
SM00053, Rev D Installation 2-17
Preinstallation requirements
INSTALLING THE HYDRAULIC PRESSURE TRANSDUCER
See the following drawing in the Drawings chapter:
❏ AR3200 Electrical Installation Kit
Mount the hydraulic pressure transducer on the hydraulic derrick plate as specified on the drawing. Read the following installation note before installing the hydraulic pressure transducer. (See the drawing for mounting dimensions.)
z The transducer uses the 1/4 in. hydraulic line in the hydraulic service loop.
2-18 AR3200 SM00053, Rev D
July 1, 2005
INSTALLING THE HYDRAULIC TORQUE GAUGE
See the following drawings in the Drawings chapter:
❏ AR3200 Installation - 59" (or 75") Track Spacing
Mount the hydraulic torque gauge in the driller’s control console as specified on the drawing.
n Make sure the operator has an unobstructed view of the gauge dial and the roughneck area of the drill floor.
Read the following installation notes before installing the hydraulic torque gauge. (See the drawings for mounting dimensions.)
z The gauge uses the 1/4 in. hydraulic line in the hydraulic service loop.
z Install a gauge damper in series between the hydraulic torque gauge and the hydraulic service loop.
SM00053, Rev D Installation 2-19
Preinstallation requirements
INSTALLING THE HYDRAULIC SERVICE LOOP
See the following drawings in the Drawings chapter:
❏ AR3200 Hydraulic Service Loop Assembly
❏ AR3200 Electrical Installation Kit
The hydraulic service loop hangs in the service loop bracket. Depending upon the configuration purchased, the AR3200 has either three or four hydraulic lines as follows:
❏ 1 in. supply
❏ 1 1/4 in. return
❏ 1/4 in. hydraulic torque gauge
❏ 1/2 in. air (UL purge and/or casing line)
e The hydraulic service loop contains an electrical line on UL configurations with purge systems on the tool and on casing-ready roughnecks. If used for any purpose, this electrical line must be terminated in the J-box.
e The self-sealing hydraulic line quick disconnects (QDs) must be fully shouldered when fastened together. If not fully shouldered, the self-sealing valves do not open or only open partially. This causes a severe drop in pressure through the QD. The drop in pressure causes the hydraulic fluid to overheat and overload the hydraulic power supply. The overload prevents the AR3200 from working correctly.
To interconnect the rig hydraulic system and the AR3200:
1. Connect the 1 1/4 in. threaded hose connector from the service loop to the 1 1/4 in. hydraulic return bulkhead fitting on the hydraulic derrick mounting plate.
2. Connect the 1 in. threaded hose connector from the service loop to the 1 in. hydraulic supply bulkhead fitting on the hydraulic derrick mounting plate.
3. Use a 1 in-to-1 1/4 in. adapter (customer supplied) to connect the supply to the return line at the tool end of the service loop.
4. Operate the hydraulic power supply for approximately 15 minutes to remove contaminants from the system. Reconnect the supply and return lines to their respective fittings after flushing the system.
5. Connect the 1 1/4 in. QD hose connector from the service loop to the 1 1/4 in. hydraulic return QD fitting on the AR3200 inlet manifold assembly.
6. Connect the 1 in. QD connector from the service loop to the 1 in. hydraulic supply QD fitting on the AR3200 inlet manifold assembly.
2-20 AR3200 SM00053, Rev D
July 1, 2005
7. Connect the 1/4 in. threaded hose connector from the service loop to the 1/4 in. hydraulic torque gauge bulkhead fitting on the hydraulic derrick mounting plate.
8. Connect the 1/4 in. QD hose connector from the service loop to the 1/4 in. hydraulic torque gauge QD fitting on the AR3200 inlet manifold assembly.
9. After connecting the AR3200 to a hydraulic power supply, remove air trapped in the system.
10. Secure the service loop to the AR3200 using brackets and bolts provided.
11. Inspect the service loop for any binding kinks, areas of contact with rig structures or other equipment, which may be detrimental to the life of the service loop.
INTERCONNECTING PURGE AIR (UL CONFIGURATIONS)
See the following drawing in the Drawings chapter:
❏ AR3200 Hydraulic Service Loop Assembly
To interconnect purge air:
1. Connect the 1/2 in. threaded hose connector from the service loop to the 1/2 in. purge air bulkhead connector on the derrick mounting plate.
2. Connect the 1/2 in. QD hose connector from the service loop to the 1/2 in. purge air QD connector on the AR3200 inlet manifold assembly.
SM00053, Rev D Installation 2-21
Preinstallation requirements
INSTALLING THE MONITOR AND OPTIONAL CONTROL STATIONS
See the following drawings in the Drawings chapter:
❏ AR3200 Installation - 59" Track Spacing
❏ AR3200 Remote Controller Assembly (PLC)
❏ AR3200 Electrical Installation Kit
❏ AR3200 Interconnect Diagram
Mount both the monitor and control stations at the driller’s control console in a convenient location for operation as specified on the drawing.
n Make sure the operator can see the hydraulic torque gauge and the roughneck area of the rig floor, as well as the controls.
Read the following installation notes before installing the monitor and control stations.
Control station options
The AR3200 has either of two control options:
❏ A monitor station, but no control station
❏ A monitor station and a control station
Table 2-4 shows the control station options and what each includes.
Table 2-4. Control station options
Station type Includes
UL monitor station Two indicator lights (one for ENGAGED and one for CLEAR) and an EMERGENCY SHUTDOWN switch (ESD).
EEx monitor station Two indicator lights (one for ENGAGED and one for CLEAR) and an EMERGENCY SHUTDOWN switch (ESD).
UL control station One trip in/trip out switch and one auto start button.
EEx control station One trip in/trip out switch and one auto start button.
2-22 AR3200 SM00053, Rev D
July 1, 2005
To install the monitor and optional control stations:
1. Connect the control station and monitor station cables from the driller’s console to the PLC box as specified on the wiring diagram.
The AR3200 Installation - 59" Track Spacing drawing provides mounting specifications.
z The monitor control station uses cable S01.The driller’s control stations uses cable S02.
2. When installing the monitor station, remove the jumper between TB3-5 and TB3-6 in the PLC assembly enclosure.
e Remove the jumper between TB3-5 and TB3-6 in the PLC assembly enclosure if the monitor station is installed. Failure to remove this jumper disables the monitor station ESD.
SM00053, Rev D Installation 2-23
Preinstallation requirements
INSTALLING THE AC VOLTAGE REGULATOR
Read the following notes before installing the AC voltage regulator. Procedures vary between nonpurged and (optional) purged installations.
Nonpurged installation
In a nonpurged installation, the AC voltage regulator (2,000VA, 50Hz) connects rig power to a PLC box. (See Installing the PLC enclosure (nonpurged) on page 2-24.) The AC voltage regulator must be installed in a safe area
UL and EEx installation
In a UL or EEx installation, the AC regulating transformer (1,500 VA, 60Hz) connects rig power to a power J-box.
General notes
Terminate derrick power leads into the AC Regulator with line power connected according to Table 2-5:
Terminate the output of the AC voltage regulator to the PLC J-box terminal TB6-1 for a regulated line and to terminal TB6-2 for neutral. Wire the ground to terminal TB6-3.
Table 2-5. Rig power
Line Voltage AC Regulator Terminal
95-130 VAC H1 and H2
175-235 VAC H1 and H3
190-260 VAC H1 and H4
380-520 VAC H1 and H5
2-24 AR3200 SM00053, Rev D
July 1, 2005
INSTALLING THE PLC ENCLOSURE (NONPURGED)
See the following drawings in the Drawings chapter:
❏ AR3200 Electrical Installation Kit drawing
❏ AR3200 Interconnect Diagram drawing
The PLC enclosure contains all components necessary for the automatic control system, except for sensors and switches. Mount the PLC in an accessible, nonhazardous area.
To install the PLC enclosure:
1. Mount the PLC enclosure onto a customer-supplied steel plate. (See the Electrical Installation Kit drawing for layout.)
2. Mount the steel plate assembly onto the rig structure in a location that is protected from the elements if possible.
INSTALLING THE OPTIONAL PLC ENCLOSURE PURGE UNIT
See the following drawings in the Drawings chapter:
❏ AR3200 Installation - 59" (or 75") Track Spacing drawing
❏ AR3200 Remote Controller Assembly (PLC) drawing
The optional PLC purge unit mounts on top of the PLC enclosure.
To install the optional PLC enclosure purge unit:
1. Remove the stiffener plate.
2. Assemble the following components:
a. Purge Airline
b. Gasket
c. PLC enclosure
d. Stiffener plate
3. Connect the purge air line and fitting to the purge air exit fitting.
4. Route the air line behind the J-box panel.
5. Use the four supplied screws to attach the PLC purge unit to the PLC enclosure.
SM00053, Rev D Installation 2-25
Preinstallation requirements
INSTALLING THE ELECTRICAL SERVICE LOOP
See the following drawings in the Drawings chapter:
❏ AR3200 Electrical Installation Kit drawing
❏ AR3200 Interconnect Diagram drawing
❏ AR3200 Derrick Plate Assembly drawing
To install and interconnect the electrical service loop:
1. Connect the electrical service loops to the derrick plate assembly.
2. Terminate pigtails in the derrick J-box.
3. Trim the wires at the end of the pigtails to length and terminate (see AR3200 Interconnect Diagram drawing).
z Varco recommends the use of crimp ferrules.
4. Make sure that the glands connecting the wire mesh armor of the cable to the J-box are properly installed to provide airtight and leakage free (U.L purge systems) shielding.
Two nuts on each gland connect it to the cable. The first nut traps the wire braid in place. The second nut provides an environmental seal. If necessary, tighten first the inner, then the outer nut to prevent dust or moisture from entering the J-box.
5. Clamp pigtails in place on the right side of the left torque wrench guard (see AR3200 Electrical Installation Kit drawing) and in two places on the left leg of the roughneck assembly.
6. Allow enough slack to cover the AR3200 travel distance to prevent binding or kinking.
7. Trim the wires at the end of the pigtails to length and terminate. (See AR3200 Interconnect Diagram drawing.)
8. Install the service loop guard over the electrical cables.
2-26 AR3200 SM00053, Rev D
July 1, 2005
AR3200
AutomatedRoughneck
Operation
July 1, 2005
3-2 AR3200 SM00053, Rev D
Operation 3-3
Chapter 3 Contents
Chapter 3 Operation
AR3200 operator controls ................................................................................ 3-5About the operator control panels ........................................................ 3-5
Torque gauge ................................................................................. 3-5Automatic Sequence controls ............................................................... 3-6
Controls in sequenced operation .................................................... 3-6Controls in manual mode ............................................................... 3-7EMERGENCY STOP (ESD) control ............................................ 3-7
Tool J-box controls .............................................................................. 3-7Manual Control Station ........................................................................ 3-7
Automatic Control Station ........................................................... 3-10Remote Monitor Station ..................................................................... 3-11Optional Remote Control Station ....................................................... 3-13Tool J-box controls ............................................................................ 3-15
Preoperation .................................................................................................... 3-16Preoperational checklist ............................................................................ 3-16
AR3200 PLC startup .......................................................................... 3-21Installing the EPROM ........................................................................ 3-21Indexing the AR3200 ......................................................................... 3-22Initializing an automatic sequence ..................................................... 3-23Setting up the AR3200 LEARN MODE ............................................ 3-24
AR3200 function tests .............................................................................. 3-26Function checks .................................................................................. 3-26
Pressure-reducing valve ............................................................... 3-26Torque Wrench ............................................................................ 3-27Spinning Wrench ......................................................................... 3-27Carriage vertical positioning ....................................................... 3-27Rolling operations ........................................................................ 3-27Tilt operation ............................................................................... 3-27Automatic makeup ....................................................................... 3-28Automatic breakout ..................................................................... 3-29Semiautomatic makeup with manual height positioning ............. 3-30Semiautomatic breakout with manual height adjustment ............ 3-31Automatic makeup, PS MODE ................................................... 3-32Automatic breakout, PS MODE .................................................. 3-33Automatic makeup, Torque Wrench backup mode (soft clamp) . 3-34Automatic breakout, Torque Wrench backup mode (soft clamp) 3-35LEARN MODE ........................................................................... 3-36
Operating procedures ...................................................................................... 3-37AR3200 checkout procedures ................................................................... 3-37Manual control switches ........................................................................... 3-38
Setting the makeup torque ........................................................... 3-38
3-4 AR3200 SM00053, Rev D
July 1, 2005
Mousehole operations ......................................................................... 3-39End-of-stroke interlock ....................................................................... 3-40
Resetting after an interlock condition .......................................... 3-40Automatic sequence control ...................................................................... 3-41
Torque Wrench backup mode ............................................................ 3-41Automatic makeup ............................................................................. 3-42Automatic breakout ............................................................................ 3-43Auto/manual height adjustment operation ......................................... 3-44
Manual positioning mode ............................................................ 3-44Autopositioning mode .................................................................. 3-44
Tool joint length and tool joint height ................................................ 3-45Horizontal/vertical position adjustments ............................................ 3-46
Purge operation ................................................................................................ 3-47Operating the purge unit for PLC enclosure ............................................. 3-49Operating the J-box purge control unit ..................................................... 3-50
IBOP hanger operation (optional) ................................................................... 3-52Commissioning Procedure (FIP00055) ........................................................... 3-52
Operation 3-5
Chapter 3
Operation
AR3200 operator controlsThe AR3200 contains the following types of controls:
❏ Manual Operator Control Panels (Figure 3-1 and Figure 3-2)
❏ Automatic Control Station on the tool (Figure 3-3)
❏ Remote Monitor Station (Figure 3-4 and Figure 3-5)
❏ Optional Remote Control Station (Figure 3-6 and Figure 3-7)
❏ Tool J-box controls (Figure 3-8)
ABOUT THE OPERATOR CONTROL PANELS
The operator controls are located on either the right or left side of the AR3200, depending upon the configuration purchased. In this manual, the left-hand configuration is illustrated, but the controls function identically, regardless of the side of the tool on which they are located.
Torque gauge
A torque gauge, located on the frame of the AR3200, helps set and verify torque when operating the tool manually. A remote torque gauge, usually mounted at the driller’s console, also indicates makeup torque.
3-6 AR3200 SM00053, Rev D
July 1, 2005
AUTOMATIC SEQUENCE CONTROLS
Automatic sequence controls are located as follows:
❏ Automatic Control Station on the tool (Figure 3-3)
❏ Remote Monitor Station (Figure 3-4 and Figure 3-5)
❏ Optional Remote Control Station (Figure 3-6 and Figure 3-7)
These remote stations can be mounted almost anywhere, although they are typically located on or near the driller’s control console.
The AR3200 requires minimal operator intervention. You set the torque and tool joint length only once per trip for each type of pipe used.
Controls in sequenced operation
After the selecting TRIP IN or TRIP OUT, press the AUTO SEQUENCE button for the AR3200 to begin a sequence of makeup or breakout functions automatically. A sequence can include positioning the unit, spinning in or out, and torquing or breaking out a joint. PLC software directs the tool to perform all normal makeup and breakout functions.
Normally, the AR3200 operates at a setting of 2,000 psi. Integrated sensors and interlocks enable the tool to perform several functions sequentially. Interlocks also prevent the operator from inadvertently initiating inappropriate operating sequences.
SM00053, Rev D Operation 3-7
AR3200 operator controls
Controls in manual mode
For drill collars or special operations, set the TJ LENGTH switch to MAN (manual mode) and set the tool to 2,500 psi. This slows the Spinning Wrench speed to prevent thread damage.
z In manual mode, none of the interlocks function, except for the end-of-stroke interlock. In this mode, only the index and position-counting sensors function.
EMERGENCY STOP (ESD) control
You can stop tool operation at any time, whether in operating manually or in sequenced mode, by pushing the EMERGENCY STOP button located on the Manual Control Station. Pulling the button out allows you to restart the operation.
TOOL J-BOX CONTROLS
The tool J-box contains switches for selecting either manual or automatic tool joint height detection and for turning the power slips mode (PS-MODE) on or off (Figure 3-9).
MANUAL CONTROL STATION
The Manual Control Station (Figure 3-1 and Figure 3-2) is located on either the right or left side of the unit and contains switches that allow you to control AR3200 functions individually. The Manual Control Station also contains an EMERGENCY STOP button. Table 3-1 describes the controls and their function.
3-8 AR3200 SM00053, Rev D
July 1, 2005
.
OUT IN
SPIN SPIN
UNCLAMP CLAMP
SPINNING WRENCH
UNCLAMP CLAMP
TORQUE WRENCH
BREAKOUT
MAKEUP
TORQUE TORQUE
PUSH TO STOP
OVERRIDEON
OFF
NORMAL BACKUP
TW MODE
VERTICAL TILT
2500 PSI 2000 PSI
PULL TO RESET
WELL HOME
UP
DONE
9 7 5 4 3
111068
2 1
12 13
Figure 3-1. Manual Control Station (left UL configuration)
TORQUE TORQUE WRENCH
TW MODE
OVERRIDEON VERTICAL TILTOFF
2500PSIPSI
2000
SPIN
OUT IN
OUT UPBREAK MAKE
SPIN. WRENCH
CLAMPUNCLAMP
UNCLAMP CLAMP
BACKUP
NORMAL
EMERGENCY STOPDOWN
HOME
UP
WELL
AUTO SEQUENCE
IN
TRIP
OUT
14 9 7 2 13 5 4 12
1110136815
Figure 3-2. Manual Control Station (left EEx configuration)
SM00053, Rev D Operation 3-9
AR3200 operator controls
Table 3-1. AR3200 Manual Control Station
# Switch Switch Type Function
1 2500 PSI/2000 PSI Two-position Selects two hydraulic operating levels. The normal operational level is 2,000 psi. Select 2,500 psi for drill collars or special operations.
2 OFF/ON/OVERRIDE Three-position Selects the operating mode of the AR3200 from the Manual Control Station.
3 EMERGENCY STOP Pushbutton Stops operation of the AR3200 when the button is pushed in. Pull out to allow operation.
4 SPINNING WRENCHUNCLAMP/CLAMP
Three-position Selects the clamping or unclamping function of the Spinning Wrench.
5 SPIN OUT/IN Three-position Selects the Spinning Wrench rotational direction.
6 HOME Pushbutton Moves the AR3200 away from well center.
7 UP Pushbutton Moves the AR3200 carriage upward.
8 DOWN Pushbutton Moves the AR3200 carriage downward.
9 WELL Pushbutton Moves the AR3200 toward well center.
10 TORQUEBREAKOUT/MAKEUP
Three-position Selects partial rotation of the upper Torque Wrench jaws in one direction or the other when the TW MODE BACKUP/NORMAL switch in the NORMAL position.
11 TORQUE WRENCH UNCLAMP/CLAMP
Three-position Selects clamping or unclamping of the upper and lower Torque Wrench jaws.
12 TW MODENORMAL/BACKUP
Two-position Selects specific combinations of operations.In backup mode, only the lower jaws are clamped, allowing the Torque Wrench to back up the spinning function (soft clamp).This mode forces the upper jaws to unclamp.
13 VERTICAL/TILT Two-position selects the vertical or tilted position of the carriage. Use tilting for making mousehole connections.
14 TRIP IN/OUT Two-position Selects the tripping mode for either making up (TRIP IN) or breaking out (TRIP OUT) sequences.
15 AUTO SEQUENCE Pushbutton Initiates the automatic makeup or breakout sequence.
3-10 AR3200 SM00053, Rev D
July 1, 2005
Automatic Control Station
The Automatic Control Station (Figure 3-3) is located either on the side of the tool adjacent to the Manual Control Station (UL) or on the Manual Control Station panel (EEx).This control station contains an AUTO SEQUENCE button that initiates a sequence. The TRIP IN/OUT switch selects the sequence for making up (TRIP IN) or breaking out (TRIP OUT) sequences.
OUT IN
TRIP
AUTOMATICSEQUENCE
Figure 3-3. Automatic Control Station (UL)
SM00053, Rev D Operation 3-11
AR3200 operator controls
REMOTE MONITOR STATION
The remote monitor station (Figure 3-4 and Figure 3-5) is typically located on or near the driller’s control console. The station includes two indicator lights (one for ENGAGED and one for CLEAR) and an Emergency Shutdown (ESD) pushbutton.
.
ENGAGED
CLEAR
PUSH TO STOP
PULL TO START
Figure 3-4. Remote monitor station (UL)
3-12 AR3200 SM00053, Rev D
July 1, 2005
PUSH TO STOPRELEASE TO START
CLEAR
ENGAGED
Figure 3-5. Remote Monitor Station (EEx)
SM00053, Rev D Operation 3-13
AR3200 operator controls
OPTIONAL REMOTE CONTROL STATION
The optional Remote Control Station (Figure 3-6 and Figure 3-7) is typically located on or near the driller’s control console. The station includes a duplicate set of Automatic Control Station controls: one TRIP IN/OUT switch and one AUTO SEQUENCE button.
Figure 3-6. Optional Remote Control Station (UL)
OUT IN
TRIP
AUTOMATICSEQUENCE
3-14 AR3200 SM00053, Rev D
TRIP
AUTOMATICSEQUENCE
OUT IN
Figure 3-7. Optional Remote Control Station (EEx)
SM00053, Rev D Operation 3-15
AR3200 operator controls
TOOL J-BOX CONTROLS
Two switches are mounted on the tool J-box (Figure 3-8). Table 3-2 explains the function of each switch.
Table 3-2. Tool joint length and power slip switches
Selector Switch Function
TJ LENGTH (MAN, 8", 10", 12", 14", HW)
MAN = Allows you to manually set the tool joint size for an irregular tool joint length when in AUTO SEQUENCE MODE. 8", 10", 12", 14" = Specifies a preset length. The AR3200 finds the tool joint automatically.HW = Sets the tool joint size to accom-modate Heavy Weight tubulars.
PS MODE (ON, OFF) Selects the power slip mode.ON = when using a power slip. The carriage mode adjusts the AR3200 carriage height to clear a power slip.OFF = when not using a power slip.
Figure 3-8. Tool joint length and power slip mode switches
HWMAN
P/N
107
475
8"
10" 12"
14"
PS-MODE
OFF ON
TJ LENGTH
Tool Joint Length Switch
Power Slip Switch
3-16 AR3200 SM00053, Rev D
July 1, 2005
PreoperationPreoperation activities include
❏ Completing the preoperational checklist
❏ Starting up the PLC
❏ Performing the AR3200 function tests
Preoperational checklistComplete the preoperational checklist Table 3-3 before operating the AR3200.
SM00053, Rev D Operation 3-17
Preoperation
Table 3-3. Preoperational checklist
Component/Assembly
Inspection Action
❏ Derrick J-box mount-ing plate
Inspect the derrick J-box plate assembly for mounting security by checking bolts and lock wire for tightness.
Secure the J-box as required.
Check electrical wiring in the derrick J-box for proper termination. The maximum resistance is 2 Ohm end-to-end.
Make sure all wires are secured. (See the electrical wiring diagrams in the Drawings chapter.
Check all electrical cables from the PLC to the derrick J-box and the derrick J-box to the AR3200 (service loops) for abrasion, pinching, cracking, kinking, and excessive bending or twisting.
Adjust.
❏ Service loops Inspect the connection between the derrick hydraulic supply line to the 1 in. hydraulic sup-ply bulkhead connector on the mounting plate. Make sure threaded fittings are fluid-tight.
Tighten as required.
Inspect the connection between the 1 in. hydraulic supply bulkhead connector on the mounting plate to the AR3200 hydraulic supply hose. Make sure threaded fittings are fluid-tight.
Tighten as required.
Inspect the connection between the 1 1/4 in. derrick hydraulic return line to the inlet manifold bulkhead connector on the mounting plate. Make sure threaded fittings are fluid-tight.
Tighten as required.
Inspect the connection between the 1 1/4 in. hydraulic return bulkhead connector on the mounting plate to the AR3200 hydraulic return hose. Make sure threaded fittings are fluid-tight.
Tighten as required.
Inspect the connection between the derrick hydraulic instrument line to the 1/4 in. hydrau-lic bulkhead connector on the mounting plate. Make sure threaded fittings are fluid-tight.
Tighten as required.
Inspect the connection between the 1/4 in. hydraulic instrument bulkhead connector on the mounting plate to the AR3200 hydraulic hose. Make sure threaded fittings are fluid-tight.
Tighten as required.
3-18 AR3200 SM00053, Rev D
July 1, 2005
❑ Inlet manifold Check hydraulic supply, hydraulic return, and hydraulic instrument QDs for fluid-tight con-nection to the inlet manifold.
Tighten as required.
Check the filter in the hydraulic system for clogging.
To clean the filter:
1. Disconnect the supply and return line QDs.
2. Remove the bolt at the bottom of the filter for drainage.
3. Drain the filter.
4. Remove the filter.
❑ Main hydraulic manifold
Check manifold-mounted pressure-reduction valves, directional control valves, pressure gauge, and hoses for tightness.
Tighten as required.
❑ Drive tracks Inspect for rail cog damage. Repair or replace as required.
Inspect mechanical stops for damage (broken stops).
Repair as required.
Inspect for level alignment and proper span. Relevel and/or align as required
Inspect mounting welds for cracks. Tighten or replace hard-ware as required. Reweld if required.
Check hinges on the hinged rails. Tighten.
❑ Frame Inspect the frame for loose or missing hardware and fittings.
Tighten or replace as required.
Check the lift cylinder, tilt cylinder, and main hydraulic manifold hoses for abrasion, pinch-ing, kinking, cracking, and excessive bending or twisting.
Replace damaged hoses as required.
Check all hydraulic hose connections from the main hydraulic manifold to the lift cylinder, tilt cylinder, and main hydraulic manifold for tight-ness.
Use a wrench to tighten the connections as required.
Check all electrical cables for abrasion, pinch-ing, kinking, cracking, and excessive bending or twisting.
Replace damaged cables as required.
Check all hoses for abrasion, pinching, kinking, cracking and excessive bending or twisting.
Replace damaged hoses as required.
Table 3-3. Preoperational checklist (continued)
Component/Assembly
Inspection Action
SM00053, Rev D Operation 3-19
Preoperation
❑ Carriage Inspect for loose or missing hardware and fittings.
Tighten or replace as required.
Check all electrical cables for abrasion, pinch-ing, and excessive bending or twisting.
Replace damaged cables as required.
Check the rollers for damage and freedom of movement.
Repair or replace as required
Inspect proximity sensors for mounting security.
Secure as required.
Inspect the proximity sensor for damage, obstructions, and proper installation.
Adjust; replace as required.
Check all hydraulic hose connections from the main hydraulic manifold to the foot assembly hydraulic motors for tightness.
Tighten as required.
❑ Torque Wrench Inspect the Torque Wrench for loose hardware and fittings.
Tighten or replace as required.
Check the Torque Wrench hoses for abrasion, pinching, cracking, kinking, and excessive bending or twisting.
Replace damaged hoses as required.
Check all hydraulic hose connections from the main hydraulic manifold to the upper and lower Torque Wrench clamping cylinders for tightness.
Tighten as required.
Check all hydraulic hose connections from the main hydraulic manifold to the upper and lower Torque Wrench torque cylinders for tightness.
Tighten as required.
Inspect the Torque Wrench jaw and make sure the tong dies are properly installed and service-able. Make sure the Torque Wrench jaw assem-bly has the correct tong dies for the pipe size used.
See the Maintenance chap-ter for details on changing tong dies.
Make sure the tool joint sensor assembly is in proper position for the pipe size.
Adjust as required.
Inspect the proximity sensors for damage, obstructions, and proper installation.
Adjust; replace as required.
Table 3-3. Preoperational checklist (continued)
Component/Assembly
Inspection Action
3-20 AR3200 SM00053, Rev D
July 1, 2005
❑ Spinning Wrench Inspect for loose hardware and fittings. Tighten.
Check the Spinning Wrench hoses for abrasion, pinching, cracking, kinking, and excessive bending or twisting.
Replace damaged hoses as required.
Check all hydraulic hose connections from the main hydraulic manifold to the Spinning Wrench clamp cylinder for tightness.
Tighten as required.
Check all hydraulic hose connections from the main hydraulic manifold to the Spinning Wrench hydraulic manifold for tightness.
Tighten as required.
Check all hydraulic hose connections from the Spinning Wrench hydraulic manifold to the Spinning Wrench hydraulic motors for tightness.
Tighten as required.
Inspect guide rollers for damage and freedom of movement.
Repair or replace as required.
❑ Control cubicle Inspect the exterior of the control cubicle for signs of damage and gland tightness. If neces-sary, adjust the gland nuts to form a climate-resistant seal.
Repair as required.
Open the electrical enclosure and inspect the door seal for signs of deterioration or damage.
Replace door seal as required.
❑ Hydraulic supply Make sure the hydraulic power supply is ser-viceable and capable of a minimum output of 2,500 psi and 45 gpm
Adjust.
Table 3-3. Preoperational checklist (continued)
Component/Assembly
Inspection Action
SM00053, Rev D Operation 3-21
Preoperation
AR3200 PLC STARTUP
To prepare the AR3200 for startup requires the following procedures:
1. Installing the EPROM (page 3-21)
2. Indexing the AR3200 (page 3-22)(Allows the system to detect the relative position of the tool.)
3. Initializing an automatic sequence (page 3-23)
4. Setting up the AR3200 LEARN MODE (page 3-24)
n Before beginning these procedures, verify that no hazardous gases are present, then install a jumper wire at the purge loss of pressure switch to enable the PLC enclosure to be energized during startup. Be sure to remove the jumper switch before operating the AR3200.
INSTALLING THE EPROM
To install the EPROM:
1. Make sure the PLC power is off.
2. Remove the battery (if already installed).
3. Insert the AR3200 EPROM into the PLC.
4. Set the Run/Stop switch to RUN.
5. Turn power on.
A yellow lamp that normally indicates a low battery illuminates.
6. The red and green LEDs on the front of PLC illuminate as follows:
a. The red LED lights up for a few seconds.
b. The red LED flickers for about two seconds.
c. The red LED extinguishes and the green LED illuminates.
7. Reinstall the battery.
The yellow lamp indicating low battery turns off.
3-22 AR3200 SM00053, Rev D
INDEXING THE AR3200
1. Make sure all AR3200 switches are set to OFF, Safe, or neutral positions.
2. Start the HPU.
3. Set the tool mode switch to ON.
4. Turn the Torque Wrench (TW) and Spinning Wrench (SW) clamp switches to the open position, then set to the center (OFF) position for automatic operation.
5. Turn the TW Make/Break switch so that the TW position proximity sensor makes contact at both ends of the stroke.
6. Drive the AR3200 forward and reverse over the cutout index slot in cog drive rail to index the horizontal counting system.
7. Six inches before well center, the AR3200 automatically sets the pressure to 2,500 psi and slows its forward speed.
8. Raise the carriage all the way up.
9. Turn the Torque Wrench and Spinning Wrench switches to the Clamp position.
10. Lower the carriage all the way to the end-of-stroke to index the vertical counting system. As the carriage moves downward, near the bottom of the stroke, it activates the end-of-stroke sensor, which causes the interlocks to open the jaws.
SM00053, Rev D Operation 3-23
Preoperation
INITIALIZING AN AUTOMATIC SEQUENCE
To initialize the AR3200 automatic sequence mode:
1. Set the Torque Wrench and Spinning Wrench clamp switches to the center (off) position.
2. Set the tilt switch to VERTICAL.
3. Set the pressure select switch to 2,000 psi.
4. Set the LEARN MODE switch to Off.
5. Set the tool mode switch to ON.
6. Set the trip mode to IN or OUT.
3-24 AR3200 SM00053, Rev D
SETTING UP THE AR3200 LEARN MODE
See Figure 3-9 before setting up the AR3200 LEARN MODE.
To set up the AR3200 LEARN MODE:
1. Set the Torque Wrench and Spinning Wrench CLAMP switches the center (OFF) position.
2. Set the TILT switch to VERTICAL.
3. Set the PRESSURE SELECT switch to 2,000 psi.
4. Set the LEARN MODE switch located in the PLC enclosure to ON.
5. Set the TOOL MODE switch to ON.
6. Drive the AR3200 forward to the well.
It is not necessary to have a pipe in the slips, but the tool must be at well center position to start.
7. Select a height (not above tool joint height) and position the carriage at that height.
8. Press the AUTO SEQUENCE button.
a. If there is an overhead obstruction, drive the AR3200 away from well at least 10 track cogs (21.5 in. minimum).
b. If there is no overhead obstruction, no duck height programming is required. Drive the AR3200 directly to the HOME position and press the AUTO SEQUENCE button.
9. Lower the carriage to the end-of-stroke and press the AUTO SEQUENCE button. This programs the duck height.
10. Drive the AR3200 to the HOME position, and press the AUTO SEQUENCE button again.
11. Set LEARN MODE switch to OFF.
z Selecting a default height of up to 7 in. (178 mm) above the end-of-stroke allows the AR3200 to follow the same positioning procedures as if the PS MODE were selected. If no overhead obstruction exists, the tool presets vertical height in the HOME position at the end of each makeup or breakout routine. If an overhead obstruction is present, the tool performs vertical positioning on the way to well center as soon as it clears the obstruction. If the learned height is zero (below detection of end-of-stroke) the carriage is left at end-of-stroke following either positioning function.
SM00053, Rev D Operation 3-25
Preoperation
Figure 3-9. AR3200 LEARN MODE diagram
Forward With ObstructionAt Well PS Zone
Forward Without ObstructionAt Well PS Zone
Learned Height
Overhead Obstruction
PS Height
Learned Height
PS Height
Note: If PS is selected, learned height will beignored and carriage destination will be PS height.
Note: If PS is selected, learned height will beignored and carriage destination will be PS height.
No vertical adjustmentallowed behind obstruction.
Reverse With ObstructionAt Well PS Zone
Learned Height
Overhead Obstruction
PS HeightNo vertical adjustmentallowed behind obstruction.
Vertical height resetat "Home" position.
Reverse Without ObstructionAt Well PS Zone
Learned Height
PS Height
Vertical height resetat "Home" position.
3-26 AR3200 SM00053, Rev D
AR3200 function testsThis section describes all AR3200 preoperational function tests. Use these checklists to make sure the AR3200 is operating properly before using the tool.
FUNCTION CHECKS
Perform function checks on the following:
❏ Pressure-reducing valve (page 3-26)
❏ Torque Wrench (page 3-27)
❏ Spinning Wrench (page 3-27)
❏ Carriage vertical positioning (page 3-27)
❏ Rolling operations (page 3-27)
❏ Tilt operation (page 3-27)
❏ Automatic makeup (page 3-28)
❏ Automatic breakout (page 3-29)
❏ Semiautomatic makeup with manual height positioning (page 3-30)
❏ Semiautomatic breakout with manual height adjustment (page 3-31)
❏ Automatic makeup, PS MODE (page 3-32)
❏ Automatic breakout, PS MODE (page 3-33)
❏ Automatic makeup, Torque Wrench backup mode (soft clamp) (page 3-34)
❏ Automatic breakout, Torque Wrench backup mode (soft clamp) (page 3-35)
❏ LEARN MODE (page 3-36)
Pressure-reducing valve
1. Select 2,000 psi on the manual controller and verify the pressure on the AR3200 gauge.
2. Select 2,500 psi on the manual controller and verify the pressure on the AR3200 gauge.
SM00053, Rev D Operation 3-27
Preoperation
Torque Wrench
1. Operate the Torque Wrench in torque mode, both fully clamped and fully unclamped (clamping speed approximately 2-3 seconds).
2. Check the dump valve for proper operation. When activated, the torque gauge should read 0-5 ft-lb.
3. Check the proximity sensor alignment with the target. The correct alignment is.16 in. + .062 in.
4. Check all fittings and hoses for leaks.
5. Operate the Torque Wrench clamp with the Normal/BACKUP switch in backup position and verify that only the lower jaw clamps.
Spinning Wrench
1. Operate the Spinning Wrench in clamp, spin in, spin out, and unclamp mode.
Do not run the spinner on the tool joint to prevent damage to the spinner motor housing.
2. Check the Spinning Wrench rpm. It should be 110-155 rpm at 2,000 psi and 30 rpm at 2,500 psi.
3. Check the clamp speed. It should be 1 1/2 to 3 seconds.
4. Check all hoses and fittings for leaks.
Carriage vertical positioning
1. Move the carriage up and down. The carriage should stay in any given position when the switch is released, without creeping.
2. Check all hoses and fittings for leaks.
Rolling operations
1. Extend and retract the tool, checking for smooth operation across the rails.
2. Make sure the tool stays in position when releasing the control.
Tilt operation
1. Check the operation of the tilt function for interference and binding. The tilt is adjustable from 3° - 7° and is preset at the factory to customer specifications.
z Forward tilt is adjustable from 3° - 7°. Reverse tilt is fixed at 7°.
2. Check all fittings and hoses for leaks.
3-28 AR3200 SM00053, Rev D
July 1, 2005
Automatic makeup
e For any automatic sequence, the TORQUE WRENCH CLAMP and SPINNING WRENCH CLAMP, TILT, and TEACH switches must be in the OFF position.
1. Locate the tool in the HOME position and fully lower the carriage.
2. Set a joint of drill pipe in the slips.
3. Lower the pin of an additional joint(s) into the box of the joint in the slip. Hold the joint loosely in elevators.
e Secure the slips before making up a single joint to prevent the drill pipe from spinning the slips in the rotary table. Do not use power slips for this operation.
1. Set the tool control switches as follows:
2. Press the AUTO SEQUENCE button and verify that the tool moves to well center. The Torque Wrench cycles to the makeup ready (full breakout) position and the tool slows down before contacting the pipe. The tool joint is positioned between the upper and lower Torque Wrench jaws.
3. Press the AUTO SEQUENCE button again and verify that the tool performs as follows:
a. Spinning Wrench clamps.
b. Performs a short spinout to engage threads.
c. Spins pipe fully into the box section.
d. Torque Wrench jaws clamp on tool joint.
e. Applies correct makeup torque (as selected by the operator using the pressure-reducing valve [PRV]).
Torque should hold until you press the AUTO SEQUENCE button again.
Switch Setting
OFF/ON/OVERRIDE ON
TJ LENGTH Select the proper tool joint length, e.g., 8", 10", 12", etc.
TRIP IN
SM00053, Rev D Operation 3-29
Preoperation
4. Press the AUTO SEQUENCE button again and verify that the tool performs as follows:
a. Spinning Wrench unclamps.
b. Torque Wrench unclamps.
c. Tool moves to the HOME position.
5. When the tool is in the HOME position, verify the following:
a. Torque Wrench recycles to makeup ready (full breakout) position.
b. Carriage is fully lowered (or at learned height).
Automatic breakout
1. Locate the tool in the HOME position and fully lower the carriage. Set the tool control switches as follows:
2. Press the AUTO SEQUENCE button.
3. Verify that the tool moves to well center. The Torque Wrench cycles to breakout ready (full makeup) position. The tool slows down before contacting the pipe and performs as follows:
a. The tool joint is positioned between the upper and lower Torque Wrench jaws.
b. The Torque Wrench and Spinning Wrench jaws clamp onto the pipe.
c. Applies breakout torque.
d. Torque Wrench unclamps.
e. Spins pipe fully out.
f. Spinning Wrench unclamps.
g. Moves to HOME position.
4. When the tool is in the HOME position verify the following:
a. Torque Wrench recycles to breakout (full makeup) position.
b. Carriage lowers fully (or at learned height).
Switch Setting
OFF/ON/OVERRIDE ON
TJ LENGTH Select the proper tool joint length, e.g., 8", 10", 12", etc.
TRIP OUT
3-30 AR3200 SM00053, Rev D
July 1, 2005
Semiautomatic makeup with manual height positioning
1. Make sure the tool is in the HOME position and the carriage is fully lowered. Set the tool control switches as follows:
2. Press the AUTO SEQUENCE button.
3. Verify that the tool moves to well center. The Torque Wrench cycles to makeup ready (full breakout) position, and the tool slows down before contact with pipe. The tool height should not change.
4. Position the Torque Wrench to proper height using the manual control vertical switches.
5. Press the AUTO SEQUENCE button again and verify that the tool performs as follows:
a. Spinning Wrench clamps.
b. Performs a short spinout to engage the threads.
c. Spins pipe fully into the box section.
d. Torque Wrench jaws clamp onto the tool joint.
e. Applies correct makeup torque (as selected using the PRV).
Torque should hold until you press the AUTO SEQUENCE button again.
6. Press the AUTO SEQUENCE button again and verify that the tool performs as follows:
a. Spinning Wrench unclamps.
b. Torque Wrench unclamps.
c. Tool moves to HOME position.
7. When the tool is in the HOME position, verify that the tool performs the following:
a. Torque Wrench returns to makeup ready position.
b. Carriage height does not change.
Switch Setting
OFF/ON/OVERRIDE ON
TJ LENGTH MAN
TRIP IN
SM00053, Rev D Operation 3-31
Preoperation
Semiautomatic breakout with manual height adjustment
1. Locate the tool in the HOME position and fully lower the carriage. Set the tool control switches as follows:
2. Press the AUTO SEQUENCE button.
3. Verify that the tool moves to well center. The Torque Wrench moves to breakout ready (full makeup) position, and the tool slows down before contacting the pipe. Tool height should not change.
4. Position the Torque Wrench to the proper height using the manual control vertical switches.
5. Press the AUTO SEQUENCE button again and verify that the tool performs as follows:
a. Torque Wrench and Spinning Wrench clamp on pipe.
b. Applies breakout torque.
c. Torque Wrench unclamps.
d. Spins pipe fully out of the box section.
e. Spinning Wrench unclamps.
f. Tool moves to HOME position.
6. When the tool is in the HOME position, verify that the tool performs as follows:
a. Torque Wrench returns to breakout ready position.
b. Carriage height does not change.
Switch Setting
OFF/ON/OVERRIDE ON
TJ LENGTH MAN
TRIP OUT
3-32 AR3200 SM00053, Rev D
July 1, 2005
Automatic makeup, PS MODE
1. Make sure the tool is in the HOME position and the carriage is fully lowered.
1. Set the tool control switches as follows:
2. Press the AUTO SEQUENCE button. Verify that the tool moves to well center, raises to power slip height, and slows down before contacting the pipe.
3. Press the AUTO SEQUENCE button again and verify that the tool performs as follows:
a. Spinning Wrench clamps.
b. Tool performs a short spin out.
c. Spins pipe fully into the box section.
d. Torque Wrench jaws clamp onto the pipe.
e. Applies correct makeup torque (as selected using the PRV).
The torque should hold until the AUTO SEQUENCE button is depressed.
4. Press the AUTO SEQUENCE button again and verify that the tool performs as follows:
a. Spinning Wrench unclamps.
b. Torque Wrench unclamps.
c. Tool moves to HOME position.
5. When the tool is in the HOME position, verify that the tool performs as follows:
a. Torque Wrench returns to makeup ready position.
b. Carriage lowers fully and then raises 7 in. (178 mm) minimum, i.e., power slip height.
Switch Setting
PS MODE ON
OFF/ON/OVERRIDE ON
TJ LENGTH Select the proper tool joint length, e.g., 8", 10", 12", etc.
TRIP IN
SM00053, Rev D Operation 3-33
Preoperation
Automatic breakout, PS MODE
1. Set the tool control switches as follows:
2. Press the AUTO SEQUENCE button. Verify that the tool moves to well center, raises to power slip height, and that the tool slows down before contacting the pipe. Make sure that the tool joint is properly positioned between the upper and lower Torque Wrench jaws.
3. Press the AUTO SEQUENCE button again and verify that the tool performs as follows:
a. Torque Wrench and Spinning Wrench jaws clamp on tool joint.
b. Breakout torque is applied.
c. Torque Wrench unclamps.
d. Spins pipe fully out of box section.
e. Spinning Wrench unclamps.
f. Tool moves to HOME position.
4. When the tool is in the HOME position, verify that the tool performs as follows:
a. Torque Wrench recycles to breakout position.
b. Carriage lowers fully and then raises 7 in. (178 mm) minimum, i.e., power slip height.
Switch Setting
PS MODE ON
OFF/ON/OVERRIDE ON
TJ LENGTH Select the proper tool joint length, e.g., 8", 10", 12", etc.
TRIP OUT
3-34 AR3200 SM00053, Rev D
July 1, 2005
Automatic makeup, Torque Wrench backup mode (soft clamp)
1. Locate the tool in the HOME position and fully lower the carriage. Set the tool control switches as follows:
2. Press the AUTO SEQUENCE button and verify that the tool moves to well center. The Torque Wrench cycles to makeup ready (full breakout) position, and the tool slows down before contacting the pipe. Make sure the tool joint is properly positioned between the Torque Wrench jaws.
3. Press the AUTO SEQUENCE button again and verify that the tool performs as follows:
a. Spinning Wrench and lower Torque Wrench jaws clamp. Upper Torque Wrench jaw remains unclamped.
b. Performs a short spin out.
c. Spins pipe fully into the box section.
d. Upper Torque Wrench jaw clamps on tool joint.
e. Applies correct makeup torque (as selected using the PRV). Torque should hold until the AUTO SEQUENCE button is depressed again.
4. Press the AUTO SEQUENCE button again and verify that the tool performs as follows:
a. Spinning Wrench unclamps.
b. Torque Wrench unclamps.
c. Tool moves to HOME position.
5. When the tool is in the HOME position, verify that the tool performs as follows:
a. Torque Wrench recycles to makeup ready position.
b. Carriage lowers fully (or at learned height).
Switch Setting
TW MODE BACKUP
OFF/ON/OVERRIDE ON
TJ LENGTH Select the proper tool joint length, e.g., 8", 10", 12", etc.
TRIP IN
SM00053, Rev D Operation 3-35
Preoperation
Automatic breakout, Torque Wrench backup mode (soft clamp)
1. Locate the tool in the HOME position and fully lower the carriage. Set the tool control switches as follows:
2. Press the AUTO SEQUENCE button. Verify that the tool moves to well center and slows down before contacting the pipe Make sure that the tool joint is properly positioned between the Torque Wrench jaws. Torque Wrench cycles to breakout ready position.
3. Press the AUTO SEQUENCE button again and verify that the tool performs as follows:
a. The Torque Wrench and Spinning Wrench jaws clamp on tool joint.
b. Breakout torque is applied.
c. The upper Torque Wrench unclamps.
d. The pipe is fully spun out of box section.
e. The lower Torque Wrench jaw unclamps.
f. The Spinning Wrench unclamps.
g. The tool moves to HOME position.
4. When the tool is in the HOME position, verify the tool performs as follows:
a. Torque Wrench recycles to breakout ready position.
b. Carriage is fully lowered.
Switch Setting
TW MODE BACKUP
OFF/ON/OVERRIDE ON
TJ LENGTH (Select the proper tool joint length, e.g., 8", 10", 12", etc.)
TRIP OUT
3-36 AR3200 SM00053, Rev D
July 1, 2005
LEARN MODE
LEARN MODE initializes the AR3200 positions.
e Depending on the rig configuration, the AR3200 may be parked beneath or in front of a structure or object. During the Learn Mode program, program the tool so that it is not possible for it to elevate or travel into these structures or objects to prevent damage to the tool.
To initialize the height, duck, and HOME positions:
1. Set the tool control switches as follows:
2. Drive the AR3200 to well center.
3. Set the carriage to the desired height and press the AUTO SEQUENCE button.
4. Drive the AR3200 in reverse from the well to the duck or HOME position.
5. Lower the carriage to the end-of-stroke and press the AUTO SEQUENCE button.
If this is the desired HOME position, set the LEARN MODE to OFF.
6. Drive the tool in reverse to the HOME position and press the AUTO SEQUENCE button.
7. Set LEARN MODE to OFF.
Selecting a default height of up to 7 in. (178 mm) above the end-of-stroke allows the AR3200 to follow the same positioning procedures as if the PS MODE were selected. If no overhead obstruction exists, the tool presets vertical height in the HOME position at the end of each makeup or breakout routine.
If an overhead obstruction is present, the tool performs vertical positioning on the way to well center after it clears the obstruction.
If the learned height is zero (below detection of end-of-stroke) the carriage is left at end-of-stroke following either positioning function.
Switch Setting
OFF/ON/OVERRIDE ON
LEARN MODE ON
SM00053, Rev D Operation 3-37
Operating procedures
Operating proceduresThis section describes the AR3200 operating procedures. Verify the items listed in AR3200 checkout procedures before operating the tool.
AR3200 checkout proceduresThe AR3200 is preset to the following settings at the factory. Before operating the tool, verify the switch settings and conditions listed on Table 3-4:
z When operating the tool in normal operation select the 2,000 psi mode and the vertical position.
Table 3-4. Verify before operating
Switch Setting
AIR SUPPLY (on PLC purge system)
ON
Pressure control regulator Adjusted so the pressure indicator rests on the safe reading on the purge pres-sure gauge.
z Run the purge cycle at least 5 times to be sure no possible contaminated air is removed from the enclosure.
Electrical supply switch ON
z The PLC control unit contains two 1-Amp and two 5-Amp circuit breakers. Make sure both sets of circuit breakers are ON.
TEACH OFF
SPARE OFF
PURGE PRESSURE ON
PLC PLC RUN
EPROM (Inserted)
ESD for monitor station in Driller’s Control Station
Pulled out
ESD for manual control box Pulled out
Manual control box switches Neutral (generally, the center position)
HPU ON
3-38 AR3200 SM00053, Rev D
July 1, 2005
Make sure the correct-size tong dies are installed for the pipe selected.
z See the Instruction Plate, Jaw Sizing Data drawing for details.
Manual control switchesManual control switches allow you to control each function of the tool individually by setting the switches mounted on the Torque Wrench guard on the side of the tool.
To operate the tool in the manual mode:
1. Verify the following settings:
2. Set the makeup torque.
Setting the makeup torque
Adjust the torque adjustment knob located on the carriage below the torque gauge.
z Make the adjustment while making up a joint.
1. Turn the knob clockwise to increase torque and counterclockwise to decrease torque.
The torque gauge indicates the actual torque. Turning the knob counterclockwise while making up a joint reduces the pressure and the gauge reading, but not the torque. In this case, break the joint, then torque it to the new, lower value.
z If you apply too much torque (overtorque), break out the pipe, then make up again. Turning the torque adjustment knob counterclockwise while in backup mode reduces the torque reading on the gauge, but not the actual torque applied to the pipe connection.
Pipe size Configuration
3 3/4 - 7 3/4 in. 86711-2
5 3/4 - 9 3/4 in. 86771-1
Switch Setting
OFF-ON-OVERRIDE ON
EMERGENCY STOP switches on the tool and on the driller’s console
Pulled out.
SM00053, Rev D Operation 3-39
Operating procedures
2. Open the Torque Wrench jaws and Spinning Wrench arms.
Once these initial settings are made, operation in the manual mode consists of using the appropriate switches to control the tool’s position, the Spinning Wrench, and the Torque Wrench functions. See AR3200 function tests on page page 3-26 for detailed operating procedures.
MOUSEHOLE OPERATIONS
The AR3200 performs mousehole operations in manual mode because of the angle of the pipe in the mousehole. The tool can be tilted or in vertical position to make the connection, depending on how close to the rotary table the mousehole is located.
Set the TW MODE to BACKUP for mousehole operations to keep the single joint below the tool from spinning.
3-40 AR3200 SM00053, Rev D
July 1, 2005
END-OF-STROKE INTERLOCK
The end-of-stroke interlock prevents damage to the AR3200. Without this safeguard, pipe could slip down when the tool is clamped to it. The resultant weight of the drill string causes the carriage counterbalance valve to relieve pressure and the carriage to drop, while still supporting the weight of the drill string.
When the AR3200 reaches the end-of-stroke, the jaws are forced open and remain open. The Spinning Wrench and Torque Wrench CLAMP/UNCLAMP switches becomes inoperative. A manual override is not possible because the tool would be damaged.
The interlock also activates when you operate the AR3200 manually. Make sure the tool operates above the 3/4 in. (19 mm) zone whenever the Torque Wrench and Spinning Wrench jaws are clamped.
Resetting after an interlock condition
To reset the tool after an interlock condition:
1. Turn the Spinning Wrench and Torque Wrench CLAMP/UNCLAMP switches to the UNCLAMP position, then to the neutral (center, OFF) position.
2. Raise the carriage to clear the interlock zone.
SM00053, Rev D Operation 3-41
Operating procedures
Automatic sequence controlWith automatic sequence control you press one button to send the tool through a sequence of operations that either makes up or breaks out a connection.
Set up the tool as follows:
Once these initial settings are made, press the AUTO SEQUENCE button to begin the automatic sequence.
TORQUE WRENCH BACKUP MODE
To operate in backup mode, turn the TW MODE switch to the BACKUP position. Backup mode has lockouts that hold the upper jaws open; only the lower jaws clamp, allowing the Torque Wrench to back up the spinning function. This feature is also known as a soft clamp.
Use the backup mode to back up the spin in and spin out operations when the slips used are not designed to react torque. Using backup mode prevents the Spinning Wrench from turning the pipe in the slips. Backup mode also is useful for lightweight pipe or short strings or when the down hole orientation of the drill string must be maintained.
z Always use the backup mode for mousehole operations.
Switch Setting
OFF-ON-OVERRIDE ON
EMERGENCY STOP switches on the tool and on the driller’s console
Pulled out.
TORQUE WRENCH and SPINNING WRENCH
Center (OFF)
TRIP IN or OUT
TORQUE ADJUST-MENT KNOB
Set the makeup torque. Make this adjustment while making up a joint.Turn the knob clockwise to increase the torque.Turning counterclockwise while making up a joint reduces the pressure and the gauge reading, but not the torque. In this case, break the joint, then torque it to the new, lower value.
3-42 AR3200 SM00053, Rev D
July 1, 2005
AUTOMATIC MAKEUP
To initiate a makeup sequence, press the AUTO SEQUENCE button.
In a makeup sequence, the AR3200 does the following:
1. Automatically moves to well center and positions itself so that the joint is located against the back of the Torque Wrench cutout.
2. Raises the carriage until it detects the upset of the tool joint. Then the tool raises or lowers to adjust the Torque Wrench to the preselected length of the tool joint:
(Dependent upon the TJ LENGTH switch setting at 8", 10", 12", 14", or HW.)
3. Halts and waits for the next stand to be stabbed into the box in the rotary table.
When this operation is complete, press the AUTO SEQUENCE button again.
4. Clamps the Spinning Wrench onto the pipe and spins in the joint.
If the AR3200 does not detect that the joint has been shouldered, press the AUTO SEQUENCE button again and continue on to the next step.
5. Clamps the Torque Wrench jaws and makes up the joint to the previously selected torque.
When the driller confirms the torque, press the AUTO SEQUENCE button to unclamp the Torque Wrench jaws.
6. Unclamps the Spinning Wrench and the sequence continues.
If the AR3200 does not reach the selected torque in the full rotation of the upper jaw, the tool automatically restrokes.
7. Moves back to the HOME position and lowers the carriage to be ready for the next sequence.
SM00053, Rev D Operation 3-43
Operating procedures
AUTOMATIC BREAKOUT
To initiate a breakout sequence, press the AUTO SEQUENCE button.
In a breakout sequence, the AR3200 does the following:
1. Automatically moves to well center and positions itself so that the joint is located against the back of the Torque Wrench cutout.
2. Raises the carriage until it detects the upset of the tool joint. Then the tool raises or lowers to adjust the Torque Wrench to the preselected tool joint length.
(Dependent upon the TJ LENGTH switch setting at 8", 10", 12", 14", or HW.)
3. Clamps the Torque Wrench and Spinning Wrench jaws and breaks out the joint a full 28° of rotation.
When complete, the Torque Wrench upper jaws unclamp partially.
4. Spins out the joint.
When spinout is complete, the Spinning Wrench unclamps. If the tool does not detect the spin out it automatically recycles.
5. Moves back to the HOME position and cycles the Torque Wrench. It then lowers the carriage to be prepared for the next sequence.
3-44 AR3200 SM00053, Rev D
July 1, 2005
AUTO/MANUAL HEIGHT ADJUSTMENT OPERATION
Manual positioning mode
To set the tool to the manual mode, set the TJ LENGTH switch on the J-box (Figure 3-8 on page 3-15) to MAN. Pressing the AUTO SEQUENCE button causes the tool to move to well center and stop. After you make the necessary height adjustments, press the AUTO SEQUENCE button again to continue with a breakout or makeup sequence.
Autopositioning mode
To set the tool to the autopositioning mode, set the TJ LENGTH switch (Figure 3-8 on page 3-15) to any position other than MAN. Pressing the AUTO SEQUENCE button causes the tool to move to well center and scan up to find the tool joint.
If a makeup sequence is in progress, the tool stops to allow the pin to be stabbed. Pressing the AUTO SEQUENCE button again causes the tool to continue with the makeup routine.
If a breakout sequence is in progress, the tool continues with the breakout routine without stopping.
SM00053, Rev D Operation 3-45
Operating procedures
TOOL JOINT LENGTH AND TOOL JOINT HEIGHT
The TJ LENGTH switch on the tool J-box (Figure 3-8 on page 3-15) selects the tool joint box length of the current string of drill pipe. The AR3200 uses this input to correctly position the Torque Wrench on the box section. Figure 3-10 defines the tool joint length.
Tool Joint Length{8", 10", 12", 14" & HW (21.5")}
Figure 3-10. Tool joint length
3-46 AR3200 SM00053, Rev D
July 1, 2005
HORIZONTAL/VERTICAL POSITION ADJUSTMENTS
You can adjust the tool’s horizontal and vertical position by manually adjusting the four-position buttons. These buttons position the tool toward or away from well center and raise and lower the carriage. Using any of the manual switches terminates an automatic sequence.
31.0"Minimum
64.0"(Maximum)
Figure 3-11. Tool joint height
SM00053, Rev D Operation 3-47
Purge operation
Purge operationTwo purge control units are available for the AR3200: one unit for the AR3200 U.L. tool J-box and an optional one for the PLC enclosure. Figure 3-12 shows the PLC purge control unit. Table 3-5 describes the component functions.
Table 3-5. PLC purge control unit functions
# Component Function
1 Purge pressure gauge Displays the purge pressure. Normal operating pressure is 10 mbarg.
2 Pressure regulator
3 Timer restrictor Controls the rate of purge air flow to the reservoir, thereby adjusting the time required for PURGE COMPLETE status.
4 Brass collar
5 Red collar
6 Green collar
8 Alarm Pressurized indicator When the electronics enclosure pressurizes to the cor-rect level and the low pressure switching valve opens, this normally red pressurized indicator changes to green.
9 Purge Complete indicator When the electronics enclosure pressurizes to the proper level and the time delay and the purge timer switching valve actuates, this normally red PURGE COMPLETE indicator changes to green.
14 Minimum pressure sensor Produces a pneumatic “pressurized” signal when the enclosed pressure is above 0.1" wc (0.25 mb). When pressurized, the Alarm Pressurized indicator changes from red to green.When pressure falls below the set point of the sensor, the “pressurized” signal goes off, causing the Alarm Pressurized indicator to come o
15 Manual drain filter
17 Flow control valve Adjusts enclosure pressure. When pressurized, the Alarm Pressurized indicator turns green.
18 Timer valve Contains an indicator. When the timer has timed out, the indicator should return to the “out” position when pressed.
20 Plug in “or” gate For alarm only option; allows air flow either to the red collar (hold-on pipe) or green collar (alarm and trip pipe).
3-48 AR3200 SM00053, Rev D
July 1, 2005
23 Alarm and trip pipe
24 Hold on pipe
25 Logic base blank plate
26 Plug (PE test point)
76 Purge time selector
Table 3-5. PLC purge control unit functions (continued)
# Component Function
308 1 0
16min
DO NOT OVERTIGHTEN
8 4 2 1
308 1 0
16min
DO NOT OVERTIGHTEN
8 4 2 1
MIN
Purge Time Selector
Door Internal
For Alarm Only Option
241
14
15
17
17 25 762 3
54
23
6
Plug-in "or" Gate (Item 20)
To Reservoirs
TimerPinchValve
BRASSRED GREEN
89
Figure 3-12. PLC purge control unit
SM00053, Rev D Operation 3-49
Purge operation
Operating the purge unit for PLC enclosureTo operate the PLC enclosure purge unit:
1. Make sure the purge rate restrictor is fully closed.
2. Verify that the pressure gauge reads 10 mbarg.
3. Turn the unit on and open the purge restrictor until the PRESSURIZED lamp is on.
4. reduce the flow rate until the PRESSURIZED lamp is off. Make sure the pressure is 5 mbarg or greater.
5. Increase the purge flow rate until the PRESSURIZED lamp is on. At this point, the purge timer starts. Make sure the purge time is at least 10 minutes.
6. When the purge timer stops, turn the power to the enclosure on.
z Varco recommends setting the purge flow rate 15 to 20 percent above the flow rate at which the PRESSURIZED lamp is on to allow a safety margin for absorbing fluctuations in the system supply pressure.
3-50 AR3200 SM00053, Rev D
July 1, 2005
Operating the J-box purge control unit To operate the purge system for the AR3200 J-box (Figure 3-13):
1. Pull the pressure control into its adjustment position.
2. Open the pressure control regulator by turning it counterclockwise to set the pressure indicator to .25 in. pressure (safe range).
3. Push the pressure control valve to snap it into its lock position.
4. Verify that the pressure indicator maintains .25 in. pressure (safe range) for one minute.
5. The nameplate mounted on the purge control unit indicates the required purge time. Turn the power switch on at completion of the purge procedure.
SM00053, Rev D Operation 3-51
Purge operation
Purge TimeNameplate
Pressure ControlRegulator Knob
Purge PressureIndicator
Purge ControlJ-Box
Figure 3-13. AR3200 J-box purge control unit
3-52 AR3200 SM00053, Rev D
July 1, 2005
IBOP hanger operation (optional)The IBOP (Internal Blowout Preventer) hanger is an optional feature with the AR3200. The IBOP and its extender are stored in a hanger that swings to the side of the tool and locks into position. In the ready-to-stab position, the bottom of the IBOP thread is located about 2 in. (51 mm) above the Torque Wrench upper and lower jaw split line.
The IBOP hanger assembly is locked in its stored position.
To operate the IBOP hanger:
1. Raise the carriage.
2. Unlock the IBOP hanger assembly by pulling the pin.
3. Swing the IBOP valve into working position.
4. Move the AR3200 to well center.
5. Clamp the Spinning Wrench onto the IBOP.
6. Stab the IBOP by lowering the carriage so that the IBOP hanger does not interfere with the clamp assembly as the IBOP is threaded in.
7. Spin in and open the Spinning Wrench.
8. Clamp the Torque Wrench onto the IBOP, apply torque, and open the Torque Wrench jaws.
9. Open the hanger at the hinges by removing the pin.
10. Move the arm back to the storage position and relock it in place.
11. Move the AR3200 to the HOME position.
Commissioning Procedure (FIP00055)See Commissioning Test Specification, FIP00055, in the Supplemental Materials chapter as preoperation and function test checklists when performing these activities.
AR3200
AutomatedRoughneck
Maintenance
July 1, 2005
4-2 AR3200 SM00053, Rev D
Maintenance 4-3
Chapter 4 Contents
Chapter 4 MaintenanceGeneral inspection requirements ....................................................................... 4-5
Scheduled inspection requirements ............................................................ 4-6Removal and installation procedures .............................................................. 4-12
Mechanical components ........................................................................... 4-12Tong die ............................................................................................. 4-12
System hydraulic components .................................................................. 4-13Inlet pressure gauge ............................................................................ 4-13Torque gauge ...................................................................................... 4-14Torque adjustment valve .................................................................... 4-15Dump valve ........................................................................................ 4-16Pressure-reducing valve ..................................................................... 4-17Carriage lift cylinders ......................................................................... 4-18Spinning Wrench main motors ........................................................... 4-19Spinning Wrench jaw motors ............................................................. 4-20Pressure-reducing valve (2,000/2,500 psi) ......................................... 4-21Speed control valve ............................................................................ 4-22Foot motor .......................................................................................... 4-22
Control manifold hydraulic components .................................................. 4-23EEx and UL directional control valves .............................................. 4-25
Electrical components ............................................................................... 4-26Tool joint position sensor ................................................................... 4-26Torque jaw position sensor ................................................................ 4-27
Adjustment procedures .................................................................................... 4-28Adjusting the Spinning Wrench speed control ......................................... 4-28Adjusting the carriage lift counterbalance ................................................ 4-29Adjusting the vertical travel speed ........................................................... 4-29Adjusting the horizontal travel speed ....................................................... 4-29Adjusting the tilt cylinder speed control ................................................... 4-30Adjusting the regenerative valves of the torque wrench clamp cylinder .. 4-30Adjusting the manual torque pressure control valve ................................ 4-31Adjusting the hydraulic pressure relief valve ........................................... 4-31Adjusting the wear plate and tool joint detector sensor ............................ 4-31Adjusting the torque wrench position sensor ............................................ 4-32Adjusting the torque wrench dump valve ................................................. 4-32Adjusting the horizontal index sensor ...................................................... 4-33Adjusting the 2,500 psi hydraulic pressure valve ..................................... 4-33Adjusting the 2,000 psi hydraulic pressure valve ..................................... 4-34Adjusting the horizontal position sensor .................................................. 4-34Adjusting the spinout sensor ..................................................................... 4-34Adjusting the tool joint length switch voltage supply .............................. 4-35
4-4 AR3200 SM00053, Rev D
September 18, 1998
Adjusting the end-of-stroke proximity sensor .......................................... 4-35Adjusting the stabbing guide .................................................................... 4-35
Maintenance 4-5
Chapter 4
Maintenance
General inspection requirementsThis section describes inspection procedures for AR3200 assemblies and components that require routine maintenance. For information on repair or replacement parts, see the individual assembly and disassembly procedures in this chapter and the Engineering Drawings in the Drawings chapter.
❏ Inspect the assemblies and components listed in the inspection tables (Table 4-1 through Table 4-5) as noted.
❏ Special inspection requirements for specific assemblies and components are described later in this section.
n Before checking hoses for damage, make sure all AR3200 components are stationary, the OFF-ON-OVERRIDE switch is off and the HPU is off.
4-6 AR3200 SM00053, Rev D
July 1, 2005
Scheduled inspection requirementsThis section describes scheduled inspection requirements for specific assemblies and components. Perform these inspections at the intervals noted in the inspection tables.
Table 4-1. Every trip
Assembly Component Check for Action
AR3200 Assembly
All Loose hardware and fittings. Tighten or replace as necessary.
Hydraulic hose connections
e Before checking hoses for
damage, make sure all AR3200
components are stationary, the
OFF/ON/OVERRIDE switch is
off and the HPU is off.
Loose connections. Tighten as required.
Hydraulic hoses (Operate in man-ual mode using all functions.)
Abrasion, pinching, kinking, cracking, or excessive bend-ing or twisting of hydraulic hoses.
Replace damaged hoses as required.
Valves, plugs, fit-tings, and tubes
Damage or leaks. Repair or replace as necessary.
Hydraulic cylin-der rod end-to cle-vis connections
Connections are properly shouldered and tight.
Tighten as required.
All cylinders Damage and leaks. Repair or replace as necessary.
Electrical cables (Operate in man-ual mode using all functions.)
Abrasion, pinching, kinking, cracking or excessive bend-ing or twisting.
Replace damaged cables as required.
Oil filter element Cleanliness. Clean or replace.
SM00053, Rev D Maintenance 4-7
General inspection requirements
TW-102 Hydraulic Torque Wrench
Tong dies Visual inspection. Wire brush before each trip.
All tool joint detector and torque wrench position sensor mounting hard-ware
Tightness. Tighten; Replace.
Hydraulic hoses Abrasion, pinching, kinking, cracking, and excessive bending or twisting.
Observes the hoses while cycling the torque wrench through clamp and unclamp functions and while cycling the torque wrench through makeup and breakout in fully clamped and unclamped positions. Replace damaged hoses as required.
e Before checking hoses for damage, make sure all AR3200 components are stationary, the OFF/ON/OVERRIDE switch is off and the HPU is off.
Electrical cables of the tool joint detector and torque wrench position proximity sensor
Abrasion, pinching, kinking, cracking, and excessive bending or twisting.
Observe the cables while cycling the torque wrench through clamp and unclamp functions and while cycling the torque wrench through makeup and breakout in fully clamped and unclamped positions. Replace damaged cables as required.
SSW-50 Spinning Wrench
Rollers Clean and check for exces-sive wear, pitting, or crack-ing.
Repair; replace.
Body Clamp the SSW-50 on pipe and verify sufficient clear-ance exists between the Spin-ning Wrench body and drill pipe.
Adjust.
Clamping arms Smooth movement through the clamp and unclamp func-tions; rollers turn smoothly without excessive noise.
Adjust; lubricate.
Clamp cylinders and motors
Damage and leaks. Repair; replace
Table 4-1. Every trip (continued)
Assembly Component Check for Action
4-8 AR3200 SM00053, Rev D
July 1, 2005
SSW-50 Spin-ning Wrench (continued)
Hydraulic hoses Abrasion, pinching, kinking, cracking, and excessive bending or twisting.
Observe the hoses while clamping and unclamping the spinner on drill pipe at well center. Replace damaged hoses as required.
e Before checking hoses for damage, make sure all AR3200 components are stationary, the OFF/ON/OVERRIDE switch is off and the HPU is off.
Spinout sensor electrical cables
Abrasion, pinching, kinking, cracking, and excessive bending or twisting.
Observe the cables while clamping and unclamping the spinner on drill pipe at the well center. Replace damaged cables as required.
Table 4-2. Daily inspection
Component Location Check for Action
TW-102 Torque Wrench
Motion between the TW-102 upper and lower jaw sets is smooth when cycling.
Correct any interference between the upper and lower jaw sets.
SSW-50 Spinning Wrench
Drive rollers Spin the pipe in until a connection shoulders and check for slippage.
Spinout sensors Proper operation
Frame and car-riage
Cam followers rotate freely.
Adjust; lubricate.
Vertical movement of car-riage in the frame is smooth and free of bind-ing.
Adjust; lubricate.
Tilt lever Assembly operates smoothly without binding.
Attachment pins and bear-ings for excessive wear and binding.
Foot assemblies Assemblies travel fully forward and backward smoothly and without excessive noise.
Adjust; lubricate.
Table 4-1. Every trip (continued)
Assembly Component Check for Action
SM00053, Rev D Maintenance 4-9
General inspection requirements
EXPO PLC purge system (optional)
Purge air supply Contains enough air to complete the operation without interruption.
Increase air
PRESSURIZED indicator
Shows green when the sys-tem is activated.
PRESSURIZATION COMPLETE indica-tor
Shows green after the purge cycle is complete (about 10 minutes).
Filter bowl Accumulated liquid. Clean, dry as necessary.
NFPA 496-type Y tool J-box purge system (optional)
Purge Pressure Gauge
Reading is stable within the safe operating range.
Adjust as necessary.
Table 4-3. Weekly inspection
Assembly Component Check for Action
AR3200 Assembly
All functions in manual mode.
All directional control valves operate properly (i.e., their spools shift fully to both sides.)
Carriage System pressure functions properly.
1. Select MANUAL mode.
2. Select 2,500 psi and verify that pressure gauge indicates 2,500 psi.
3. Select 2,000 psi and verify that pressure gauge indicates 2,000 psi.
TW-102 Torque Wrench
Dump valve Proper operation. See Adjusting the torque wrench dump valve on page 4-33.
Position proximity sensor
Gap between the sensor and target place is .12 to .20 in. (3 to 5 mm).
Adjust.
Entire assembly Excessive wear or hard-ware breakage.
Repair; replace.
Table 4-2. Daily inspection (continued)
Component Location Check for Action
4-10 AR3200 SM00053, Rev D
July 1, 2005
SSW-50 Spinning Wrench
All of the follow-ing pins:
• Hinge pins
• Clamp cylinder pins
• Clevis clamp pins
• Trunnion pins
Excessive wear. Repair; replace.
Manifold Valves, plugs, fit-tings, and tubes
Damage and leaks.
Directional control valves
Excessive humming noise, heat build up, or high cur-rent indicate when spools are not shifting fully. Typical operating current is .6 Amp.
Repair; replace
Cleanliness; inspect for excessive wear or hard-ware breakage.
Inlet manifold Filter element Inspect for cleanliness Clean as required. A popout indicator on the filter housing protrudes when you need to replace the filter.
EXPO PLC purge system (optional)
Purge control unit Indications of damage. Repair; replace faulty components.
PLC enclosure Signs of damage, leaks, and moisture accumula-tion.
Repair; replace faulty components.
Pressure switch Damage and leaks Replace.
Purge tubing Loose fittings, damage, and leaks.
Replace.
Filter bowl Accumulated liquid Clean, dry as necessary.
Filter element Inspect for cleanliness. Clean as required. A popout indicator on the filter housing pops out when you need to replace the filter.
Table 4-3. Weekly inspection (continued)
Assembly Component Check for Action
SM00053, Rev D Maintenance 4-11
General inspection requirements
Optional NFPA 496-type Y tool J-box purge system
Fittings Leaks Tighten as required.
Filter (if used) Cleanliness. Clean or drain as necessary.
Purge loss-of-pres-sure switch
Switch operates properly Adjust; replace.
Pressure gauge sintered vent on the bottom of the tool J-box
Cleanliness and passage of air.
Air supply Cleanliness and dryness. Change air supply if necessary.
Table 4-4. Every three months
Assembly Component Check for Action
Foot assemblies Foot gearbox Remove the covers and inspect the gearboxes for play in the bearings and for excessive shaft wear.
After inspection, repack the gearboxes with grease. Replace the gaskets when reinstalling the cover. See
EXPO PLC purge system (optional)
Air supply inlet Pressure is correct. Adjust as necessary
Purge flow Flow rate is correct. Adjust as necessary.
NFPA 496 type Y tool J-box purge system (optional)
Tool J-box Accumulation of mois-ture, dirt, or oil due to dirty supply air.
Clean and dry. Check air supply.
Enclosure protec-tion vent
Proper operation. Repair, replace as necessary.
Inlet pressure Inspect for proper pressure. Adjust pressure.
Table 4-3. Weekly inspection (continued)
Assembly Component Check for Action
4-12 AR3200 SM00053, Rev D
July 1, 2005
Table 4-5. Every six months
Component Check for Action
TW-102 Torque Wrench Wear on the following:
• Hinge pins
• Clamp cylinder pins
• Clamp cylinder pins
• Torque cylinder clevis pins
• Torque cylinder trunnion
• pins
Repair/replace
SM00053, Rev D Maintenance 4-13
Removal and installation procedures
Removal and installation proceduresThis section describes removal and installation procedures for AR3200 components. See the appropriate drawings in the Drawings chapter when removing or installing a component.
n Make sure maintenance personnel are familiar with the lockwire procedures contained in ASP00019 in the Supplemental Materials chapter.
Mechanical componentsThis section describes removal and installation procedures for mechanical components.
TONG DIE
❏ See Engineering Drawing: Instruction Plate, Jaw Sizing Data
Change the tong dies to fit the selected pipe size. Use configuration 86711-2 for pipe size 3 1/2" to 7 3/4" and configuration 86711-1 for pipe size 5 3/4" to 9 3/4."
Removal
❏ See Engineering Drawing: Torque Wrench Jaw Assembly
1. Open the jaws fully.
2. Turn off the hydraulic power supply.
3. Reduce the hydraulic pressure to zero.
4. Turn off all electrical power to the AR3200.
5. Remove the mounting bolts from die retainer and remove retainer.
If the retainer is difficult to pull out, remove the two outer plugs and tighten the pry-out set screws, forcing the retainer assembly out of its socket.
6. Remove the die stop mounting bolts from the die retainer.
7. Remove the tong die.
Installation
❏ See Engineering Drawing: Torque Wrench Jaw Assembly
1. Clean the groove of any debris.
2. Install the new tong die in the retainer.
3. Install the die stop against the tong die and tighten the bolts.
4. Install the retainer into its socket and secure the mounting bolts.
4-14 AR3200 SM00053, Rev D
July 1, 2005
System hydraulic componentsThis section describes removal and installation procedures for hydraulic components.
INLET PRESSURE GAUGE
Removal
❏ See Engineering Drawing: AR3200 Iron Roughneck Assembly
1. Turn off the hydraulic power supply.
2. Reduce the hydraulic pressure to zero.
3. Turn off all electrical power to the AR3200.
4. From the rear of the AR3200, locate the inlet pressure gauge tubing and connector on the right side of the carriage.
5. Remove the tubing connector from the elbow mounted on the rear of the inlet pressure gauge.
6. Install a plug in the open connector to prevent debris and contaminants from entering the hydraulic line.
7. From the right side of the AR3200 carriage remove three screws securing the gauge to the carriage.
8. Remove the inlet pressure gauge from the carriage.
9. Note the position of the elbow relative to the gauge.
10. Remove the elbow from the inlet pressure gauge.
Installation
❏ See Engineering Drawing: AR3200 Iron Roughneck Assembly
1. Wrap the threads of the elbow with antiseize tape.
2. Install the elbow in the pressure port of the inlet pressure gauge and position the elbow to the position noted in step 9 of the removal procedure.
3. From the right side of the AR3200, place the elbow and body of the inlet pressure gauge through the mounting hole in the carriage and secure the gauge to the carriage using three screws.
4. From the rear of the AR3200, locate the gauge hydraulic line and remove the protective plug from the connector.
5. Attach the connector to the gauge elbow and secure.
SM00053, Rev D Maintenance 4-15
Removal and installation procedures
TORQUE GAUGE
Removal
❏ See Engineering Drawing: AR3200 Iron Roughneck Assembly
1. Turn off the hydraulic power supply.
2. Reduce the hydraulic pressure to zero.
3. Turn off all electrical power to the AR3200.
4. From the rear of the AR3200, locate the torque gauge tubing and fittings on the right side of the carriage.
5. Disconnect the gauge tubing connector from the tee.
6. Install a cap over the open tee to prevent debris and contaminants from entering the hydraulic line.
7. From the right side of the AR3200 carriage, remove three hex bolts securing the gauge to the carriage.
8. Remove the torque gauge from the carriage.
9. Disconnect the tubing from the gauge and remove.
Installation
❏ See Engineering Drawing: AR3200 Iron Roughneck Assembly
1. Install the tubing assembly on the torque gauge and secure.
2. From the right side of the AR3200, place the elbow and body of the torque gauge through the mounting hole in the carriage and secure the gauge to the carriage using three hex-head bolts.
3. From the rear of the AR3200, locate the gauge hydraulic line and remove the protective cap from the tee.
4. Connect the gauge tubing connector to the tee and secure.
4-16 AR3200 SM00053, Rev D
July 1, 2005
TORQUE ADJUSTMENT VALVE
Removal
❏ See Engineering Drawing AR3200 Iron Roughneck Assembly
1. Turn off the hydraulic power supply.
2. Reduce the hydraulic pressure to zero.
3. Turn off all electrical power to the AR3200.
4. From the rear of the AR3200 locate the torque adjustment valve tubing and connector on the right side of the carriage.
5. Remove the tubing connector from the elbow mounted on the rear of the torque adjustment valve.
6. Install a plug in the open connector to prevent debris and contaminants from entering the hydraulic line.
7. From the right side of the AR3200 carriage remove four socket-head cap screws securing the valve to the carriage.
8. Remove the torque adjustment valve from the carriage.
9. Note the position of the elbow relative to the valve.
10. Remove the elbow from the torque adjustment valve.
Installation
❏ See Engineering Drawing AR3200 Iron Roughneck Assembly
1. Wrap the threads of the elbow with antiseize tape.
2. Install the elbow in the pressure port of the torque adjustment valve and position the elbow to the position noted in step 9 of the removal procedure.
3. From the right side of the AR3200, place the elbow and body of the torque adjustment valve through the mounting hole in the carriage and secure the valve to the carriage using socket-head cap screws.
4. From the rear of the AR3200, locate the valve hydraulic line and remove the protective plug from the connector.
5. Attach the connector to the valve elbow and secure.
SM00053, Rev D Maintenance 4-17
Removal and installation procedures
DUMP VALVE
Removal
❏ See Engineering Drawing: TW-102 Torque Wrench Assembly
1. Turn off the hydraulic power supply.
2. Reduce the hydraulic pressure to zero.
3. Turn off all electrical power to the AR3200.
4. From the left side of the AR3200, remove the retaining pin from the TW guard and swing the guard open.
5. Disconnect the hydraulic line from the side of the dump valve.
6. Install a plug in the open line connector to prevent debris and contaminants from entering the hydraulic line.
7. Disconnect the hydraulic line from the end of the dump valve.
8. Install a plug in the open line connector to prevent debris and contaminants from entering the hydraulic line.
9. Remove the hex retaining nut from the valve body.
10. Remove the dump valve from the valve mounting bracket.
Installation
❏ See Engineering Drawing: Torque Wrench Assembly
1. From the left side of the AR3200, install the dump valve in the valve mounting bracket and secure with hex nut.
2. Remove the protective plug from the side hydraulic line.
3. Install the hydraulic line on the valve side nipple and secure.
4. Remove the protective plug from the end hydraulic line.
5. Install the hydraulic line on the valve end nipple and secure.
6. Check for proper operation and adjust as necessary. (See Adjusting the torque wrench dump valve on page 4-33.)
7. Close the TW guard and secure with the retaining pin.
4-18 AR3200 SM00053, Rev D
July 1, 2005
PRESSURE-REDUCING VALVE
Removal
❏ See Engineering Drawing: Valves, Manifold Assembly
1. Turn off the hydraulic power supply.
2. Reduce the hydraulic pressure to zero.
3. Turn off all electrical power to the AR3200.
4. From the rear of the AR3200, locate the pressure-reducing valve on the rear of the main hydraulic manifold.
5. Remove the 3/8" connector from the tee.
6. Install a cap over the open tee to prevent debris and contaminants from entering the hydraulic line.
7. Remove the 1/4" connector from tee.
8. Install a cap over the open tee to prevent debris and contaminants from entering the hydraulic line.
9. Remove four socket-head cap screws and four lockwashers from the reducing valve and manifold.
10. Remove the pressure-reducing valve from the main manifold.
11. Remove all packing from the valve and manifold ports.
12. Discard packing.
Installation
❏ See Engineering Drawing: Valves, Manifold Assembly
1. Install new packing in the pressure-reducing valve ports.
2. Align the pressure-reducing valve mounting holes with the mounting holes in the main manifold, install four lockwashers and four socket-head cap screws.
3. Secure the socket-head cap screws.
4. Remove the cap from the 1/4" tee, install the line, and secure.
5. Remove the cap from the 3/8" tee, install the line, and secure.
SM00053, Rev D Maintenance 4-19
Removal and installation procedures
CARRIAGE LIFT CYLINDERS
Removal
❏ See Engineering Drawing: AR3200 Iron Roughneck Assembly
1. Lower the carriage to the full bottom position.
2. Turn off the hydraulic power supply.
3. Reduce the hydraulic pressure to zero.
4. Turn off all electrical power to the AR3200.
5. From the rear of the AR3200, locate the faulty cylinder.
6. Support the AR3200 carriage so it cannot move.
7. Remove the cotter pin from the lower cylinder pivot pin.
8. Remove the bottom pivot pin from the cylinder and carriage mount.
9. Support the bottom of the cylinder before removing the upper pivot pin.
10. Remove the cotter pin from the upper cylinder pivot pin.
11. Remove the top pivot pin from the cylinder and remove the cylinder from the AR3200.
12. Remove the clevis from the cylinder rod end.
Installation
❏ See Engineering Drawing: AR3200 Iron Roughneck Assembly
1. Install the clevis on the cylinder rod end.
2. Place the cylinder in AR3200 with the rod end upward.
3. Align the cylinder clevis with the frame bracket and install the pivot pin.
4. Install a new cotter pin in the pivot pin.
5. Align the lower cylinder yoke with the carriage mount and install the pivot pin.
6. Install a new cotter pin in the pivot pin.
4-20 AR3200 SM00053, Rev D
July 1, 2005
SPINNING WRENCH MAIN MOTORS
Removal
❏ See Engineering Drawing: Spinning Wrench-50 Assembly
1. Turn off the hydraulic power supply.
2. Reduce the hydraulic pressure to zero.
3. Turn off all electrical power to the AR3200.
4. Disconnect the 1/4" connector from the motor.
5. Install a plug in the open connector to prevent debris and contaminants from entering the hydraulic line.
6. Disconnect and match-mark as A and B the two 1/2" connectors from the motor.
7. Install a plug in the open connectors to prevent debris and contaminants from entering the hydraulic lines.
8. Support the motor before removing the retaining bolts.
9. Remove three hex-head bolts and lock wire from the motor and wrench body.
10. Remove the motor from the wrench body.
Installation
❏ See Engineering Drawing: Spinning Wrench 50 Assembly
1. Insert the spline shaft of the motor in the wrench body and align with the splines in the roller shaft.
2. Align the mounting holes of the motor with the mounting holes in the wrench body and install three hex bolts and lock wire.
3. Secure the bolts with lockwire in accordance with ASP00019 in the Supplemental Materials chapter.
4. Remove the plugs from the 1/2" connector and connect the lines to the 1/2” motor fittings using the A and B marks to match the proper connectors and secure.
5. Remove the plug from the 1/4" connector and connect the line to the 1/4” motor fitting and secure.
SM00053, Rev D Maintenance 4-21
Removal and installation procedures
SPINNING WRENCH JAW MOTORS
Removal
❏ See Engineering Drawing: Spinning Wrench 50 Assembly
1. Turn off the hydraulic power supply.
2. Reduce the hydraulic pressure to zero.
3. Turn off all electrical power to the AR3200.
4. Disconnect the 1/4” hydraulic line from the motor.
5. Install a plug in the open connector to prevent debris and contaminants from entering the hydraulic line.
6. Disconnect and match-mark as A and B the two 1/2” hydraulic lines from the motor.
7. Install a plug in the open connectors to prevent debris and contaminants from entering the hydraulic lines.
8. Support the motor before removing the retaining bolts.
9. Remove three hex-head bolts and lock wire from the motor and wrench arm.
10. Remove the motor from the wrench jaw.
Installation
❏ See Engineering Drawing: Spinning Wrench SSW-50 Assembly
1. Insert the spline shaft of the motor in the wrench arm and align with the spline in roller shaft.
2. Align the mounting holes of the motor with the mounting holes in the wrench jaw and install three hex bolts.
3. Secure the bolts with lockwire.
4. Remove the plugs from the 1/2" hydraulic lines and connect the lines to the 1/2” motor fittings and secure.
5. Remove the plug from the 1/4” hydraulic line and connect the line to the 1/4” motor fitting, using the A and B marks to match the proper fitting, and secure.
4-22 AR3200 SM00053, Rev D
July 1, 2005
PRESSURE-REDUCING VALVE (2,000/2,500 PSI)
Removal
❏ See Engineering Drawing: Valves, Manifold Assembly B16
1. Turn off the hydraulic power supply.
2. Reduce the hydraulic pressure to zero.
3. Turn off all electrical power to the AR3200.
4. From the rear of the AR3200, locate the 2,000/2,500 psi pressure-reducing valve on the rear of the main manifold.
5. Disconnect the electrical connector from the valve solenoid.
6. Remove four socket-head cap screws and four lockwashers.
7. Remove the reducing valve from the manifold.
8. Remove all packing from the valve and manifold ports.
9. Discard packing.
Installation
❏ See Engineering Drawing: Valves, Manifold Assembly
1. Install new packing on all valve ports.
2. Align the mounting holes on the valve with the mounting holes on the main manifold and install four lockwashers and four socket-head cap screws.
3. Secure the socket-head cap screws.
4. Connect the electrical connector to valve solenoid.
SM00053, Rev D Maintenance 4-23
Removal and installation procedures
SPEED CONTROL VALVE
Removal
❏ See Engineering Drawing: Valves, Manifold Assembly
1. Turn off the hydraulic power supply.
2. Reduce the hydraulic pressure to zero.
3. Turn off all electrical power to the AR3200.
4. From the rear of the AR3200, locate the speed control valve mounted on the rear of the main manifold.
5. Unscrew the speed control valve from the manifold.
6. Remove packing from valve or manifold and discard.
Installation
❏ See Engineering Drawing: Speed Control Valve
1. Install new packing on speed control valve.
2. Install the valve in the mounting hole in the manifold and secure.
FOOT MOTOR
Removal
❏ See Engineering Drawing: Foot Assembly
1. Turn off the hydraulic power supply.
2. Reduce the hydraulic pressure to zero.
3. Remove the cover plate.
4. Remove the gear cover plate.
5. Remove the gear cover gasket.
6. Remove the cotter pin, nut, and gear motor retainer.
7. Remove the drive gear.
8. Disconnect and match-mark the two hose assemblies A and B.
9. Unbolt the motor assembly by removing the cotter pin and retaining nut. Remove the assembly.
4-24 AR3200 SM00053, Rev D
July 1, 2005
Installation
❏ See Engineering Drawing: Foot Assembly
1. Mount the motor assembly using the retaining nut and new cotter pin.
2. Connect the two hose assemblies using the A and B marks to make the proper connections.
3. Mount the drive gear and replace the cotter pin, nut, and gear motor retainer.
4. Replace the gear cover gasket with a new one.
5. Reinstall the cover plate.
Control manifold hydraulic componentsSee Table 4-6 and the Valves, Manifold Assembly drawing for a listing and stacking order of control manifold hydraulic components when performing the maintenance procedures in this section.
Table 4-6. Manifold-mounted components
Top component name
Second component name
Third component name
Fourth component
“Wrench Spin” 3-Position, 35 gpm Valve
None None None
“Vertical Travel” 3-Position, 15 gpm Valve
Dual Flow-control Valve
Counterbalance Valve Anticavitation Valve
“Horizontal Travel” 3-Position, 15 gpm Valve
Decel Valve Cross-Port Relief Valve
None
“Spinning Wrench” 3-position, 15 gpm Valve
Pressure Port Check Valve
None None
“Carriage Tilt” 2-Position, 15 gpm Valve
Pressure Port Check Valve
Dual Flow-control Valve
None
“TW Upper Clamp” 3-Position, 35 gpm Valve
Regenerative Valve None None
SM00053, Rev D Maintenance 4-25
Removal and installation procedures
“TW Lower Clamp” 3-Position, 35 gpm Valve
Regenerative Valve None None
“Torque Wrench” 3-position, 35 gpm Valve
"T" Check Sandwich Valve
None None
Table 4-6. Manifold-mounted components (continued)
Top component name
Second component name
Third component name
Fourth component
4-26 AR3200 SM00053, Rev D
July 1, 2005
EEX AND UL DIRECTIONAL CONTROL VALVES
This section contains removal and installation procedures for the following stacked EEx and UL directional control valves:
❏ Vertical Travel Directional Control Valve
❏ Horizontal Travel Directional Control Valve
❏ Spinning Wrench Directional Control Valve
❏ Carriage Tilt Directional Control Valve
❏ TW Upper Clamp Directional Control Valve
❏ TW Lower Clamp Directional Control Valve
❏ Torque Wrench Directional Control Valve
Removal
1. Turn off the hydraulic power supply.
2. Reduce the hydraulic pressure to zero.
3. Turn off all electrical power to the AR3200.
4. Remove four bolts from the carriage front plate and remove the front plate.
5. Locate the valve on the front of the main manifold.
6. Remove one socket-head cap screw (EEx)/nut (UL) from the end of each solenoid coil housing and remove both solenoid coil housings from the valve.
7. Remove four socket-head cap screws (EEx)/nuts (UL) from the valve assembly.
8. Remove the valve and the valve stackup from the main manifold.
9. Remove packing from all manifold ports and discard.
10. Separate stacked components from the valve assembly. (See Table 4-6.)
11. Remove packing from valve ports and discard.
e Improperly installed solenoids may damage armature tubes.
SM00053, Rev D Maintenance 4-27
Removal and installation procedures
Installation
1. Install new packing in valve ports.
2. Stack up the Dual Flow Control valve, the Counterbalance valve, the Anticavitation valve, and the valve assembly as per Table 4-6.
3. Align the valve mounting holes in the stackup and install four lock washers and four socket-head cap screws (EEx)/nuts (UL).
4. Align the screws (EEx)/nuts (UL) with the mounting holes in the main manifold and attach the valve stackup to the manifold.
5. Secure the socket-head cap screws (EEx)/nuts (UL).
6. Install both solenoid coil housings on the valve assembly and install one socket-head cap screw (EEx)/nut (UL) in each.
7. Secure the screws (EEx)/nuts (UL).
8. Align the mounting holes in the carriage front plate with the mounting holes in the carriage and install four hex bolts.
9. Secure the hex bolts.
Electrical components
TOOL JOINT POSITION SENSOR
Removal
❏ See Engineering Drawing: AR3200 Auto Electrical Assembly Drawing
1. Turn off the hydraulic power supply.
2. Reduce the hydraulic pressure to zero.
3. Turn off all electrical power to the AR3200.
4. From the left side of the carriage remove the retaining pin and open the TW guard.
5. Open the sensor J-box and disconnect the tool joint sensor wiring from the terminal strip.
6. From the front of the unit below the torque wrench lower jaw, remove the retaining nut from the tool joint position sensor.
7. Remove the sensor and wiring from AR3200.
4-28 AR3200 SM00053, Rev D
July 1, 2005
Installation
1. From the front of the AR3200, install the tool joint sensor in the sensor mounting bracket and install the retaining nut.
2. Adjust the sensor per the adjustment procedure provided later in this guide.
3. Secure the retaining nut.
4. Crimp the ferrules to the lead wires.
5. Route the sensor wiring to the sensor J-box and connect it to the terminal strip.
6. Close the sensor J-box.
7. Close the TW guard and secure it with the retaining pin.
TORQUE JAW POSITION SENSOR
Removal
❏ See Engineering Drawing: AR3200 Auto Electrical Assembly Drawing
1. Turn off the hydraulic power supply.
2. Reduce the hydraulic pressure to zero.
3. Turn off all electrical power to the AR3200.
4. From the left side of the carriage, remove the retaining pin and open the TW guard.
5. Open the sensor J-box and disconnect the torque jaw position sensor wiring from the terminal strip.
6. Remove the retaining nut from the torque jaw position sensor.
7. Remove the sensor and wiring from the AR3200.
Installation
1. From the front of the AR3200, install the torque jaw position sensor in the sensor mounting bracket and install the retaining nut.
2. Adjust the sensor per the adjustment procedure provided later in this guide.
3. Secure the retaining nut.
4. Crimp the ferrules to the lead wires.
5. Route the sensor wiring to the sensor J-box and connect it to the terminal strip.
6. Close the sensor J-box.
7. Close the TW guard and secure it with the retaining pin.
SM00053, Rev D Maintenance 4-29
Adjustment procedures
Adjustment proceduresThis section describes adjustment procedures necessary to maintain optimal AR3200 operation. In general, refer to the appropriate adjustment procedure after replacing or servicing any component.
Adjusting the Spinning Wrench speed control ❏ See Engineering Drawing: Valves, Manifold Assembly
Adjusting the hydraulic flow to the Spinning Wrench motors changes the spin-in/spin-out speed. The speed control valve is located high on the back of the hydraulic valve manifold and is labelled “SC.”
To adjust the Spinning Wrench speed control:
1. Set the AR3200 to 2,500 psi.
2. Adjust the SC valve on the hydraulic valve manifold clockwise (faster) or counterclockwise (slower) to adjust the Spinning Wrench speed for 5 in. OD pipe to 30 + 5 rpm.
3. Set the AR3200 to 2,000 psi.
4. The Spinning Wrench speed for 5 in. OD pipe should be 125 + 25 rpm.
4-30 AR3200 SM00053, Rev D
July 1, 2005
Adjusting the carriage lift counterbalance❏ See Engineering Drawing: Valves, Manifold Assembly
The carriage lift counterbalance allows the raised carriage lift cylinder to relieve pressure when the carriage is supporting a large weight. The counterbalance is located behind the Vertical Travel directional control valve, between the Speed Control and Anticavitation valves.
To adjust the carriage lift counterbalance:
1. Loosen the lock nut and turn the valve counterclockwise all of the way out.
2. Raise the carriage and release the button. The carriage should not move.
3. Turn the valve in clockwise until the carriage begins to lower.
4. Adjust the valve until it is to the balance point (the valve setting at which the carriage just holds without dropping).
5. Turn the valve out counterclockwise an additional 1/4 turn.
6. Tighten the lockout.
Adjusting the vertical travel speed ❏ See Engineering Drawing: Valves, Manifold Assembly
Two vertical travel speed control valves are located behind the vertical travel solenoid. Adjusting the vertical travel speed control valves changes the vertical speed in both directions at which the carriage moves. One valve adjusts the speed of travel when the carriage raises (on the left from the tool’s perspective). The other valve adjusts the speed of travel when the carriage lowers (on the right from the tool’s perspective). Turning either valve clockwise increases the associated vertical travel speed. Turning either valve counterclockwise decreases the associated vertical travel speed. Set the vertical travel speed in both directions to approximately 5 - 6 in./sec (127 -152mm/sec).
Adjusting the horizontal travel speed ❏ See Engineering Drawing: Valves, Manifold Assembly
Adjusting the horizontal travel speed changes the speed of the drive foot motors. The horizontal travel speed adjustment valve is located behind the horizontal travel solenoid valve. Adjust the drive foot motors to travel approximately 12 + 2 in./sec. (304 + 51 mm/sec.) The deceleration speed is set by an orifice at the 2,500 psi mode.
SM00053, Rev D Maintenance 4-31
Adjustment procedures
Adjusting the tilt cylinder speed control ❏ See Engineering Drawing: Valves, Manifold Assembly
The tilt cylinder speed control valves control the speed of the tilt cylinder function. The two valves are located behind the tilt cylinder solenoid valve.
Turning the right valve clockwise increases the tilt cylinder speed when traveling to the vertical position. Turning the right valve counterclockwise decreases the tilt cylinder speed when traveling to the vertical position.
Turning the left valve clockwise increases the cylinder speed when tilting. Turning the left valve counterclockwise decreases the tilt cylinder speed when tilting.
Adjusting the regenerative valves of the torque wrench clamp cylinder ❏ See Engineering Drawing: Valves, Manifold Assembly
The regenerative valves of the torque wrench clamp cylinder control the speed boost of the clamp cylinder. One regenerative valve is located on the left side of each torque wrench clamp solenoid valve.
Turning the regenerative valve counterclockwise increases the clamp cylinder speed; turning it clockwise decreases the clamp cylinder speed.
Turn the valve counterclockwise until maximum speed is reached. Adjust the speed to obtain equal clamping speed of the upper and lower jaws, within approximately 2-3 seconds. Then adjust the speed as required to avoid false reading of the flow switch. If the flow switch reading is wrong, the torque wrench prestrokes.
4-32 AR3200 SM00053, Rev D
July 1, 2005
Adjusting the manual torque pressure control valveThe manual torque pressure control valve controls the makeup torque. The valve is located below the torque gauge, on the right side of the roughneck.
To adjust the torque pressure control valve:
z Make the adjustment while making up a joint.
Turn the knob clockwise to increase torque and counterclockwise to decrease torque.
z The torque gauge indicates the actual torque. Turning the knob counterclockwise while making up a joint reduces the pressure and the gauge reading, but not the torque. In this case, break the joint, then torque it to the new, lower value.
If you apply too much torque (overtorque), break out the pipe, then make up again. Turning the torque adjustment knob counterclockwise while in backup mode reduces the torque reading on the gauge, but not the actual torque applied to the pipe connection.
Adjusting the hydraulic pressure relief valve ❏ See Engineering Drawing: Valves, Manifold Assembly
The hydraulic pressure relief valve controls the hydraulic pressure of the torque wrench. It is located on the lower back of the valve manifold assembly.
Turn the valve clockwise to obtain the maximum pressure setting.
Adjusting the wear plate and tool joint detector sensor ❏ See Engineering Drawing: AR3200 Auto Electrical Assembly
❏ AR3200 Automated Iron Roughneck Assembly
The wear plate is mounted under the carriage and supports the tool joint detector sensor.
The tool joint detector sensor senses the presence of the metal pipe and is located under the torque wrench.
SM00053, Rev D Maintenance 4-33
Adjustment procedures
To adjust the wear plate for the selected pipe size:
1. Remove the two fitted screws on the bottom left and right side of the wear plate.
2. Loosen the two screws in the slotted holes.
3. Slide the wear plate out (toward well center) for pipe sizes 3 1/2 in. to 7 3/4 in., or slide it in for pipe size 5 3/4 in. to 9 3/4 in. until the loosened screws slide into the new slotted position on the carriage.
4. Tighten the loosened screws and the fitted screws.
5. Adjust the sensor to .12 to .18 in. behind the face of the bracket.
6. Adjust the bracket to .63 in. travel available using the travel adjustment screw.
Adjusting the torque wrench position sensor❏ See Engineering Drawing: AR3200 Auto Electrical Assembly
The torque wrench position sensor senses the position of the torque wrench during makeup end-of-stroke (EOS) and breakout EOS.
Adjust the sensor to .10 to .22 in. from the target as required.
Adjusting the torque wrench dump valve❏ See Engineering Drawing: TW 102 Torque Wrench Assembly
The torque wrench dump valve dumps torque wrench pressure to a faulty reading on the torque meter.
Adjust the valve to dump pressure on the torque meter when the torque wrench torque cylinder reaches the end-of-stroke.
Once the valve is activated, the torque gauge should read 0 to 5 ft lb.
4-34 AR3200 SM00053, Rev D
July 1, 2005
Adjusting the horizontal index sensor❏ See Engineering Drawing: AR3200 Auto Electrical Assembly
The horizontal index sensor, located in the right foot of the tool, detects slots in the track. The sensor controls initiation of deceleration when approaching the pipe.
On upgraded AR3000 tools only, adjust the sensor to .31 to .34 in. (7.8 to 8.6 mm) above the track by loosening three attachment bolts on the side of the right foot. Then adjust the height manually. The AR3200 does not require adjustment of the horizontal index sensor.
Adjusting the 2,500 psi hydraulic pressure valve❏ See Engineering Drawing: Valves, Manifold Assembly
The 2,500 psi hydraulic pressure valve sets the operating pressure in 2,500 psi mode. The valve is located high on the back of the valve manifold assembly, below the Spinning Wrench speed control valve.
To adjust the pressure:
1. Adjust the power unit to 2,500 to 3,000 psi.
2. Set the 2,000/2,500 psi mode switch to 2,500 psi.
3. Adjust the valve to 2,500 psi, using the tool pressure gauge on the right side of the tool.
4. Turn the valve clockwise to increase the pressure and counterclockwise to decrease the pressure.
SM00053, Rev D Maintenance 4-35
Adjustment procedures
Adjusting the 2,000 psi hydraulic pressure valve❏ See Engineering Drawing: Valves, Manifold Assembly
The 2,000 psi hydraulic pressure valve sets the tool’s operating pressure in 2,000 psi mode. The valve is located with the 2,500 psi hydraulic pressure valve described above.
To adjust the pressure:
1. set the 2,000/2,500 psi mode switch to 2,000 psi.
2. Adjust the valve to 2,000 psi, using the tool pressure gauge.
3. Turn the valve clockwise to increase the pressure and counterclockwise to decrease the pressure.
Adjusting the horizontal position sensor❏ See Engineering Drawing: Valves, Manifold Assembly
The horizontal position sensor counts the cogs as the drive wheel rotates. The sensor is located in the left foot of the tool.
Adjust the sensor to .08 to .10 in. (distance between the sensor and the top of the cog). Verify the correct distance between the sensor and each cog by measuring.
Adjusting the spinout sensor ❏ See Engineering Drawing: AR3200 Auto Electrical Assembly
The spinout sensor detects the amount of shock as the threads disengage. It is located on a bracket that is attached to the Spinning Wrench.
To adjust the sensor, remove the J-box housing cover. Adjust the sensor to .100 in. Increase the distance to increase the sensor’s sensitivity.
4-36 AR3200 SM00053, Rev D
July 1, 2005
Adjusting the tool joint length switch voltage supply ❏ See Engineering Drawing: AR3200 Remote controller (PLC Assembly).
The tool joint length switch voltage is supplied by the potentiometer driver. The voltage supply is located inside the PLC box.
Set the voltage to 10 V. To adjust the value, turn the screw on top of the potentiometer clockwise to increase the voltage and counterclockwise to decrease the voltage.
Adjusting the end-of-stroke proximity sensor❏ See Engineering Drawing: AR3200 Electrical Assembly
The end-of-stroke proximity sensor, located at the top of the slave cylinder, detects the target at the bottom of the stroke.
Adjust the sensor to .04 to .06 in. (1 to 1.5 mm) above the target.
Adjusting the stabbing guide❏ See Engineering Drawing: AR3200 Automated Iron Roughneck Assembly
1. Use the horizontal travel and vertical travel controls to position the torque wrench on the tool joint box.
2. Close the lower jaws.
3. Stab the next stand.
4. Loosen two adjusting nuts and align the inside edge of the stabbing guide with the outer circumference of the pipe. Tighten the nuts.
5. When coming out of the hole or when handling drill collars, unscrew the front nuts and push the guide back, out of the way.
AR3200
AutomatedRoughneck
Lubrication
July 1, 2005
5-2 AR3200 SM00053, Rev D
Lubrication 5-3
Chapter 5 Contents
Chapter 5 Lubrication
Lubrication schedules ........................................................................................ 5-5Lubrication procedures .................................................................................... 5-10
Lubricating the frame and carriage ........................................................... 5-10Lubricating the foot assemblies ................................................................ 5-11Lubricating the tilt lever ........................................................................... 5-12Lubricating the TW-102 Hydraulic Torque Wrench ................................ 5-13Lubricating the SSW-50 Spinning Wrench Assembly ............................. 5-14
5-4 AR3200 SM00053, Rev D
July 1, 2005
Lubrication 5-5
Chapter 5
Lubrication
Lubrication schedulesThis section identifies recommended lubricants and hydraulic fluids (Table 5-1), and provides lubrication schedules for AR3200 assemblies and components (Table 5-2 through Table 5-4). See the referenced figures and engineering drawings for grease fitting locations.
5-6A
R3200
SM
00053, Rev D
July 1, 2005Table 5-1. Recommended lubricants and hydraulic fluids
A M B I E N T T E M P E R A T U R E R A N G E
Manufacturer General Purpose Grease Motor GreaseExtreme Pressure/
Severe Service GreaseGear Oil Hydraulic Oil
Above -20 C Below -20 CAll Temperatures
Above -20 C Below -20 C Above -21 C 7 to 30 C -6 to 16 C 40 to 65 C 25 to 55 C
Castrol MP grease - - - Alpha LS-320 Alpha-150 Alpha LS-68 Hyapin AWS-46
Hyapin AWS-32
Chevron Avi-Motive Avi-Motive - - - Alpha LS-320 NL Gear 150 NL Gear 68 AW Hyd oil 46
AW Hyd Oil 32
Exxon Lidok EP2 Lidok EP1 - - - Alpha LS-320 Spartan EP 150
Spartan EP68
Nuto H46 Nuto H32
Gulf Gulf Crown EP32
Gulf Crown EP31
- - - EP Lube HD320
EP Lube HD150
EP Lube HD68
Harmony 46 AW
Harmony 32AW
Mobile Mobilux EP2 Mobilux EP1 - - - MobileGear 632
MobileGear 629
MobileGear 626
DTE25 DTE24
Shell Alvania EP2 Alvania EP1 Cyprina RA P/C 70437 - Omala320 Omala150 Omala68 Tellus46 Tellus32
Statoil Uniway EP2N Uniway EP2N - - - LoadwayEP320
LoadwayEP150
Statoil HydrawayHMA46
HydrawayHMA32
Texaco Multifak EP2 Multifak EP2 - - - Meropa 320 Meropa 150 Meropa 68 Rando oil HD46
Rando oil HD32
Total Multis EP2 Multis EP2 - - - Carter EP 320
CarterEP 150 Carter EP 68 Azolia ZS46 Azolia ZS32
Union Unoba EP2 Unoba EP2 - - P/C 54810 Extra Duty NL6EP
Extra Duty NL4EP
Extra Duty NL2EP
Unax AW46 Unax AW32
NGLI 2 1 - 2 1 - - - - -
AGMA - - - - - 6EP 4EP 2EP 1 -
ISO Viscosity Grade
- - - - - 320 150 68 46 32
SM00053, Rev D Lubrication 5-7
Lubrication schedules
Table 5-2. Lubricate each trip
Component Location Reference Method
Frame and carriage Figure 5-2 and AR3200 Automated Roughneck drawing
Apply general purpose EP grease to all frame and car-riage grease fittings.
Foot assemblies Figure 5-1 Apply general purpose EP grease to all foot assembly grease fittings each trip.
Tilt lever Figure 5-3 and Stan-dard Tilt Lever Assem-bly drawing
Apply general purpose EP grease to all grease fittings.
TW-102 Hydraulic Torque Wrench
Figure 5-4 and TW-102 Torque Wrench Assembly drawing
Apply general purpose EP grease to all grease fittings.
Clamp cylinder pins Apply greases to the four fittings.
Hinge pins Apply grease to the four fittings.
Torque cylinder clevis pins Apply grease to the four fittings.
Upper and lower torque cylinder trunnion pins
Apply grease to the four fittings.
Upper roller bearing (Each side) Apply grease to the two fittings.
5-8 AR3200 SM00053, Rev D
July 1, 2005
SSW-50 Spinning Wrench
All grease fittings Figure 5-5 and SSW-50 Spinning Wrench Assembly drawing
Apply general purpose EP grease.
Upper roller bearing Apply grease to the two fittings.
Clamp arm hinge pin (Each side) Apply grease.
Upper cylinder trunnioin (Each side) Apply grease.
Lower cylinder trunnion (Each side) Apply grease.
Rear cam roller (Each side) Apply grease.
Forward cam roller (Each side) Apply grease.
Spherical rod-end bearing (Each side) Apply grease.
Lower roller bearings (Each side) Apply grease to the two fittings.
Foot assembly Rear drive roller shaft (Each foot) Apply grease to the fitting.
Front idler roller shaft (Each foot) Apply grease to the two fit-tings.
Table 5-2. Lubricate each trip (continued)
Component Location Reference Method
SM00053, Rev D Lubrication 5-9
Lubrication schedules
Table 5-3. Weekly lubrication
Component Location Reference Method
SSW-50 Frame/carriage
Forward spinner carriage rollers
Figure 5-5 Apply grease to the two fittings.
Rear spinner carriage rollers
Apply grease to the two fittings.
Upper cam followers Apply grease to the two fittings.
Rear cam followers Apply grease to the two fittings.
Lower cam followers Apply grease to the two fittings.
Tilt lever/carriage Pivot pin Figure 5-3 Apply grease to the two fittings.
Cam follower bearing Apply grease to the two fittings.
Table 5-4. Every three months lubrication
Component Location Reference Method
Foot Assembly Gearboxes Figure 5-1 After inspection, repack with grease and install new gaskets before reinstalling the foot gearbox covers.
5-10 AR3200 SM00053, Rev D
July 1, 2005
Lubrication procedures
Lubricating the frame and carriageFigure 5-1 shows the location of the frame and carriage grease fittings. Apply general purpose EP grease to all frame and carriage grease fittings each trip. (See also Table 5-1, Recommended lubricants and hydraulic fluids, on page 5-6.
UpperCamFollowerGreaseFitting(2 PL)
Rear CamFollowerGreaseFitting(2 PL)
Lower CamFollowerGreaseFitting(Far End)(2 PL)
ForwardSpinnerCarriageRollersGrease Fitting(Farside) (2 PL)
Rear SpinnerCarriageRollersGrease Fitting(2 PL)
Figure 5-1. Lubricatin g the AR3200 frame and carria ge
SM00053, Rev D Lubrication 5-11
Lubrication procedures
Lubricating the foot assembliesSee Figure 5-2 for foot assembly grease fitting locations. Apply general purpose EP grease to all foot assembly grease fittings each trip. (See also Table 5-1, Recommended lubricants and hydraulic fluids, on page 5-6.)
Foot Gear Boxes (2)(Far Side)
(Same Lubrication Points on Both Feet)
Rear DriveRoller Shaft (2)
Front IdlerRoller Shaft (2)
Figure 5-2. Lubricating the AR3200 foot assemblies
5-12 AR3200 SM00053, Rev D
July 1, 2005
Lubricating the tilt leverSee Figure 5-3 and the following engineering drawing:
Tilt Lever Assembly, Standard, for grease fitting locations. (See also Table 5-1, Recommended lubricants and hydraulic fluids, on page 5-6.).
Tilt Lever / Carriage Pivot PinGrease Fitting
Cam FollowerGrease Fitting
Figure 5-3. Lubricating the tilt lever
SM00053, Rev D Lubrication 5-13
Lubrication procedures
Lubricating the TW-102 Hydraulic Torque WrenchSee Figure 5-4 and the TW-102 Torque Wrench Assembly engineering drawing for torque wrench grease fitting locations. See also Table 5-1, Recommended lubricants and hydraulic fluids, on page 5-6.
Clamp Cylinder PinGrease Fitting (2)
Clamp Cylinder PinGrease Fitting (2)
Torque CylinderClevis PinGrease Fitting
Torque CylinderTrunnion PinGrease Fitting (2)
Hinge PinGrease Fitting (2)
Hinge PinGrease Fitting (2)
Figure 5-4. Lubricating the TW-102 Torque Wrench
5-14 AR3200 SM00053, Rev D
July 1, 2005
Lubricating the SSW-50 Spinning Wrench AssemblySee Figure 5-5 and SSW-50 Spinning Wrench Assembly engineering drawing for Spinning Wrench grease fitting locations. (See also Table 5-1, Recommended lubricants and hydraulic fluids, on page 5-6.)
.
Upper Roller BearingGrease Fitting
Upper Roller BearingGrease Fitting
Upper Cylinder TrunnionGrease Fitting
Lower CylinderTrunnionGrease Fitting
Forward Cam RollerGrease Fitting(Far End)
Lower Roller BearingGrease Fitting
Lower Roller BearingGrease Fitting
Rear Cam RollerGrease Fitting(Far End)
Spherical Rod End BearingGrease Fitting
Clamp Arm Hinge PinGrease Fitting
Figure 5-5. Lubricating the AR3200 Spinning Wrench
AR3200
AutomatedRoughneck
Troubleshooting
July 1, 2005
6-2 AR3200 SM00053, Rev D
Troubleshooting 6-3
Chapter 6 Contents
Chapter 6 Troubleshooting
Troubleshooting components ............................................................................ 6-5Troubleshooting mechanical components .................................................. 6-6
Torque Wrench ................................................................................... 6-11Spinning Wrench ................................................................................ 6-14
Troubleshooting hydraulic circuits and valves ......................................... 6-16Pressure-reducing valve circuit (PRV) ............................................... 6-17Lift cylinder circuit ............................................................................ 6-19Horizontal travel circuit ..................................................................... 6-20Spinning Wrench clamp circuit .......................................................... 6-21Spinning Wrench spin circuit ............................................................. 6-22Tilt cylinder circuit ............................................................................. 6-23Torque Wrench clamp circuit ............................................................. 6-24
Soft clamp mode .......................................................................... 6-24Torque cylinders circuit ..................................................................... 6-25Directional valves ............................................................................... 6-26
About directional solenoid-controlled valves .............................. 6-26General diagnostic procedure for solenoid-controlled valves ..... 6-26Isolating a faulty solenoid-operated directional valve ................. 6-27Repairing a stuck spool ................................................................ 6-27Two-position, solenoid-operated, four-way, (spring offset) ........ 6-28Three-position, solenoid-operated, four-way (spring-centered),float center ................................................................................... 6-29Three position, pilot-operated, solenoid controlled, four-way (spring-centered), float center ...................................................... 6-30
Load-holding valves ........................................................................... 6-32Counterbalance valve, pilot assisted ............................................ 6-32Relief valve, pilot-operated ......................................................... 6-35Check valve, pilot-operated ......................................................... 6-37
Pressure control valves ....................................................................... 6-39Pilot-operated, pressure-reducing valve ...................................... 6-39
Auxiliary valves ................................................................................. 6-41Check valve, pilot-to-close .......................................................... 6-41Check valve ................................................................................. 6-43
Flow valves ........................................................................................ 6-44Orifice .......................................................................................... 6-44Pressure-compensated, fixed orifice ............................................ 6-45Flow control valve, adjustable, pressure compensated, full reverse free flow .................................................................... 6-47
Output actuators ........................................................................................ 6-49Hydraulic cylinders ............................................................................ 6-49Hydraulic motors ................................................................................ 6-51
6-4 AR3200 SM00053, Rev D
July 1, 2005
Troubleshooting electrical and control system components ........................... 6-53Causes of malfunction ............................................................................... 6-53AR3200 control system ............................................................................. 6-53Troubleshooting the PLC .......................................................................... 6-56
Last resort PLC troubleshooting procedure ........................................ 6-56PLC power supply .............................................................................. 6-62Digital input/output module ............................................................... 6-62Control system inputs ......................................................................... 6-65
Encoders ....................................................................................... 6-65Proximity sensors ............................................................................... 6-66Intrinsic safety devices ....................................................................... 6-67
Zener safety barriers .................................................................... 6-67Intrinsically safe amplifiers ......................................................... 6-68Transformer isolated barriers ....................................................... 6-70
Troubleshooting 6-5
Chapter 6
Troubleshooting
Troubleshooting componentsPotential AR3200 component failure falls into the following categories:
❏ Mechanical components
❏ Hydraulic components
❏ Electrical and control system components
Use the troubleshooting tables (Table 6-1 through Table 6-5) and the Troubleshooting Flow Chart, (Figure 6-10 on page 6-55) to help determine the source and remedy for an AR3200 operational problem. More detailed information on various components is presented later in this chapter.
6-6 AR3200 SM00053, Rev D
July 1, 2005
Troubleshooting mechanical componentsThis section describes troubleshooting procedures for AR3200 mechanical components.
Table 6-1. Operating mode problems
Symptom Probable cause Remedy
Tool does not operate manually.
No AC power going to the sole-noids.
No hydraulic power.
Verify the following:
1. ESD switches are pulled out (reset position) on the manual control box and driller’s monitor station.
2. The ON/OFF/OVERRIDE switch on the manual control box is set to ON.
3. The purge system is set for proper operation.
4. PLC box circuit breakers have closed circuits.
5. Hydraulic pressure gauge provides the expected reading.
When operating the tool manu-ally, one solenoid does not function when sequenced.
The tool has a loose connection or a defective coil.
Place the tool in an auto sequence and check the control function. If operating, check the manual con-trol switch and circuit.
In an auto sequence, the tool does not move forward to well center.
Malfunction of the horizontal sole-noid or malfunction of the solenoid driver.
Check solenoid operation and/or solenoid driver.
In an auto sequence, the tool moves toward the well but fails to stop the hydraulic drive motor.
Malfunction of the tool joint detec-tor sensor and/or the IS amplifier.
Check the tool joint detector sensor and cable for physical damage.Check the amplifiers for correct operation.
Horizontal solenoid is sticking. Check the horizontal solenoid.
With a preset height selected, tool does not stop vertical up movement at the shoulder.
Vertical solenoid is sticking. Check the vertical solenoid.
SM00053, Rev D Troubleshooting 6-7
Troubleshooting mechanical components
With a preset height selected, the tool finds the shoulder but not the tool joint.
Vertical height sensor is not operat-ing.
Verify the following:
1. All wiring associated with the vertical sensor is correct.
2. Encoder power supply, Zener barriers, and optical isolator function properly.
The tool does not spin the pin section completely out of the box.
Improper adjustment of the spinout sensor.
Check sensor adjustment. (See Adjusting the spinout sensor in the Maintenance chapter.)
Defective spinout sensor. Check all wiring associated with the spinout sensor. (See the Spin Out Sensor drawing in the Draw-ings chapter.)
The tool fails to detect when the pin has shouldered up with the box section during a spin in function.
Failure to detect no flow caused by a defective flow switch.
Check all wiring. See the Electrical drawings in the Drawings chapter and rig-specific electrical drawings.
z If the spinner rollers continue after shouldering, a “no flow” condition is not detected. Flow dividers in the Spinning Wrench hydraulic circuit should prevent this from occurring. (See Table 6-5, Troubleshooting the Spinning Wrench, on page 6-14.)
Table 6-1. Operating mode problems (continued)
Symptom Probable cause Remedy
6-8 AR3200 SM00053, Rev D
July 1, 2005
The Torque Wrench cycles over to one side in preparation for either a makeup or breakout sequence and the sequence stops.
Malfunction of the Torque Wrench position sensor and/or the IS amplifier.
1. Check the Torque Wrench proximity sensor for proper height above the metal target. Adjust the height to within 3/16" from the metal target.
2. Check the metal target alignment when the Torque Wrench is at both full makeup or breakout position. The target should cover the proximity sensor.
3. Place a metal object in front of the sensor and monitor the LED on the IS amplifier. The LED should be on when metal is present and off when not present. Replace the sensor and/or the IS amplifier.
Tool runs slowly. Hydraulic quick disconnect (QD) on the supply or return line is not fully shouldered.
Tighten until fully shouldered.
Power unit is not delivering the full flow.
Check the power supply flow while the SSW-50 spinout valve is actu-ated. Flow should be 40 gpm minimum.
Power unit return line filter is dirty. Replace the filter element.
Pressure filter is dirty. Replace the filter element.
System pressure gauge shows inconsistent pressure reading or gauge needle bounces.
Contaminated or defective dual pressure-reducing valve on the back of the manifold.
Inspect, clean, or replace.
Table 6-1. Operating mode problems (continued)
Symptom Probable cause Remedy
SM00053, Rev D Troubleshooting 6-9
Troubleshooting mechanical components
Table 6-2. Horizontal positioning problems
Symptom Probable cause Remedy
The AR3200 moves in one direction only or does not move at all.
Power supply is not operating. Check the power supply pressure gauge for indication. Make sure supply pressure remains high with the operating valve energized.
Flow control valve on the manifold is defective, contaminated, or is not adjusted properly.
Clean, repair or adjust the valve.
Motor is defective or contaminated.
Clean or repair the motor.
Dual cross-port relief valve on the manifold is defective, contami-nated, or is not adjusted properly.
Clean, repair, or adjust the valve.
Defective solenoid-operated valve. Operate the solenoid valve manu-ally; replace if defective.
Gears are jammed. Inspect and clean or replace.
Feet are not aligned with each other (cog drive only).
Check that both feet are properly aligned on the rails.
6-10 AR3200 SM00053, Rev D
July 1, 2005
Table 6-3. Vertical positioning problems
Symptom Probable cause Remedy
Vertical positioning assembly moves in one direction only or does not move at all.
Power supply is not operating. Check the power supply pressure gauge for indication. Make sure supply pressure remains high with the operating valve energized.
Counterbalance valve on the manifold is defective, contami-nated, or is not adjusted properly.
Clean, repair or adjust the valve.
Defective solenoid-operated valve. Operate the solenoid valve manually; replace if defective.
Lift cylinders are damaged or dirty. Clean or repair the cylinder.
Binding or carriage in the pedestal. Lubricate or replace the side rollers.
Vertical positioning assembly does not maintain vertical position.
Counterbalance valve is out of adjustment.
Clean, replace or adjust the coun-terbalance valve to maintain vertical position with the operating valve in neutral.
Lift cylinders leak. Replace the seals.
Defective solenoid-operated valve. Operate the solenoid valve manually; replace if defective.
SM00053, Rev D Troubleshooting 6-11
Troubleshooting mechanical components
TORQUE WRENCH
Table 6-4 describes troubleshooting procedures for the torque wrench.
Table 6-4. Troubleshooting the torque wrench
Symptom Probable cause Remedy
Torque cylinders do not make up.
Torque-adjusting valve is improperly set.
Check that the valve is not set too low.
Torque-adjusting valve or pres-sure-reducing valve is stuck closed, dirty, or damaged.
Check valves, clean or replace.
Torque cylinder is damaged. Check, clean, or replace.
Dump valve is stuck open (depressed, pressure does not build up).
Manually actuate the valve, repair or replace it is faulty.
Check valve on the manifold is contaminated or defective.
Check, clean or replace.
Defective solenoid-operated valve. Operate the solenoid valve manually; replace if defective.
Flow divider valve on the manifold is contaminated or defective.
Check the valve, clean or replace.
Torque cylinders do not main-tain equal stroke while the bodies clamp and unclamp.
Flow divider valve on the manifold is contaminated or defective.
Check the valve, clean or replace.
Check valve on the manifold is contaminated or defective.
Check the valve, clean or replace.
Torque cylinders do not break out.
Torque-adjusting valve (makeup only) or pressure-reducing valve is stuck closed, dirty, or damaged.
Check valves, clean or replace.
Check valves on the manifold are contaminated or defective.
Check the valves, clean or replace.
Defective solenoid-operated valve. Operate the solenoid valve manually; replace it if defective.
6-12 AR3200 SM00053, Rev D
July 1, 2005
Torque cylinders drift in the makeup direction.
Sticking or worn main operating valve.
Disassemble the valve, inspect for contamination or wear, and repair or replace.
Torque cylinders drift in the breakout direction.
Excessive back pressure on the return line.
Check for restriction in return line. Check the hydraulic power supply.
Sticking or worn main operating valve.
Disassemble the valve, inspect for contamination or wear, and repair or replace.
Dirty filter in the power supply. Replace the filter element.
Air in the torque gauge or lines. Bleed the gauge or the lines.
Torque gauge does not indicate pressure during make up.
Dirty inlet port or gauge. Clean the inlet port or replace gauge.
Dump valve is stuck open (depressed, pressure does not build up).
Manually actuate valve, repair or replace if faulty.
Torque cylinders reached the end of stroke and actuated the dump valve.
Reset for additional stroke.
Gauge damper is closed. Open the damper (rotate counterclockwise).
Torque gauge does not return to zero.
Gauge is not adjusted to zero. Rotate the zero adjust knob on the back of the gauge case. Recheck the torque setting.
Defective gauge. Replace.
Joint is not centered in the torque wrench upper jaws when clamped.
Torque cylinders do not maintain equal stroke while bodies are clamping.
See the remedy provided for torque cylinders on this table.
Table 6-4. Troubleshooting the torque wrench (continued)
Symptom Probable cause Remedy
SM00053, Rev D Troubleshooting 6-13
Troubleshooting mechanical components
Jaws slip on the tool joint. Worn or broken dies. Replace the dies.
Pressure from hydraulic power supply is too low.
Set the pump outlet pressure to above 2,500 psi.
Pressure setting of the AR3200 dual pressure-reducing valve is set too low.
Set AR3200 dual pressure-reducing valve (on the AR3200 manifold) to 2,000 psi when the selector switch is at 2,000 psi and to 2,500 psi when the selector switch is at 2,500 psi position.
Pressure is bleeding off from the clamp cylinders.
Inspect for defective or contami-nated pressure port check valve under the main operational valve.
Upper torque wrench body set lifts while cycling in makeup or breakout mode.
Interference between the upper and lower body sets.
Check and remove interference.
Torque Wrench clamp cylin-ders are too slow or uneven.
Regenerative valves on the mani-fold are contaminated, defective, or not adjusted properly.
Clean, repair, or adjust the valves.
Check the defective solenoid oper-ated valve.
Operate the solenoid valve manually; replace if defective.
Lack of lubrication Lubricate all grease fittings.
Table 6-4. Troubleshooting the torque wrench (continued)
Symptom Probable cause Remedy
6-14 AR3200 SM00053, Rev D
July 1, 2005
SPINNING WRENCH
Table 6-5 describes troubleshooting procedures for the Spinning Wrench.
Table 6-5. Troubleshooting the Spinning Wrench
Symptom Probable cause Remedy
Spinning Wrench arms do not clamp or unclamp and/or motor does not run.
Flow is restricted. Locate the cause of the restriction and correct it.
Power supply is defective. Check the power supply pressure gauge for indication. make sure the supply pressure remains high with the operating valve energized.
Defective solenoid-operated valve. Operate the solenoid valve manually; replace if defective.
Defective solenoid driver. Replace the solenoid driver.
Arms or motor creep with the valve in neutral position
Leaking or sticky control valve. Return the valve to center position manually. If the problem persists, inspect the valve spool for wear or contamination.
Motor runs irregularly. Contaminated motor. Clean the motor.
Defective motor. Repair the motor or replace.
Arms to not move in unison. Defective linkage. Check the hinge pins and bores and repair or replace as required.
Lack of lubrication. Lube all the grease fittings.
Defective bearing in the arm, body, or cylinder.
Repair or replace.
Drive roller does not turn with the motor running.
Sheared drive roller key. Replace the key.
Broken motor drive shaft. Replace the motor.
Drive roller does not turn, motor stalls at full torque.
Motor seal is blown. Replace the motor seal. Check that motor drain lines are open to tank.
Loss of power or torque. Power supply is not operating. Check the power supply pressure gauge for indication. Make sure the supply pressure remains high with the operating valve energized.
Restricted hydraulic lines. Check for pinched, clogged, or oth-erwise obstructed hydraulic lines. Clean the obstruction.
Worn motor. Replace the motor.
Worn valve. Replace the valve.
SM00053, Rev D Troubleshooting 6-15
Troubleshooting mechanical components
Worn internal valves on the motor. Repair the motor
Pressure filter on the AR3200 is dirty.
Replace the filter element.
Motor stops rotating while spinning in or spinning out.
Flow to the motor is restricted. Locate the cause of restriction and correct it.
Defective drive roller bearings. Replace the bearings.
Defective motor. Repair the motor.
Motor drive shaft is broken. Replace the shaft.
Drill pipe or collars rub against the body of the wrench during spinning.
Drive roller is worn excessively. Replace the drive roller.
Drive rollers slip. Insufficient clamping pressure. Check the power supply outlet and set it above 2,500 psi. Check for leaks in the clamping lines and replace as required. Inspect for defective or contaminated pressure port check valve under the main operating valve and clean or replace as required.
Corrosion- preventing coating on new drill pipe is making the surface too slippery.
Remove the coating.
Rollers are worn. Replace the rollers.
One or two drive rollers slip. Defective, leaking, or sticking flow divider(s).
Inspect the flow divider(s), repair or replace as necessary.
Roller is worn. Replace the roller.
SSW-50 does not spin, spins too fast, or too slowly when the pressure selection switch is at 2,500 psi.
Speed-control valve on the back of the manifold is defective, contami-nated, or not adjusted properly.
Adjust, clean, or repair the valve.
Table 6-5. Troubleshooting the Spinning Wrench (continued)
Symptom Probable cause Remedy
6-16 AR3200 SM00053, Rev D
July 1, 2005
Troubleshooting hydraulic circuits and valvesThis section describes the AR3200 hydraulic components, their function, and operation.
The AR3200 contains the following hydraulic circuits and valves:
❏ Pressure-reducing valve circuit (page 6-17)
❏ Lift cylinder circuit (page 6-19)
❏ Horizontal travel circuit (page 6-20)
❏ Spinning Wrench clamp circuit (page 6-21)
❏ Spinning Wrench spin circuit (page 6-22)
❏ Tilt cylinder circuit (page 6-23)
❏ Torque Wrench clamp circuit (page 6-24)
❏ Torque cylinders circuit (page 6-25)
❏ Directional valves (page 6-26)
❏ Load-holding valves (page 6-32)
❏ Pressure-control valves (page 6-39)
❏ Auxiliary valves (page 6-41)
❏ Flow valves (page 6-44)
SM00053, Rev D Troubleshooting 6-17
Troubleshooting mechanical components
PRESSURE-REDUCING VALVE CIRCUIT (PRV)
Hydraulic fluid flows from the hydraulic power unit through a high-pressure filter mounted on the AR3200 (Figure 6-1), and to the main manifold through a pressure-reducing valve. The PRV is a large, normally open valve controlled by smaller pilot-operated valves. Valve A is set to 2,000 psi and valve B to 2,500 psi. An electrical solenoid valve that can select either 2,000 psi or 2,500 psi controls the pilot line from the main PRV and the A and B PRVs.
When the solenoid valve deenergizes, the pilot line from the 2,000 psi PRV flows to the tank. When pressure reaches 2,000 psi in the pilot line going to the A valve, the valve opens. The pressure on the inlet side of the PRV reduces more than the pilot pressure applied to the side of the main PRV opposite the spring. This closes the main PRV. The pilot line going to the A and B PRVs also goes to a speed-control valve. At 2,000 psi, the normal operating pressure of the AR3200, all circuits work at full speed.
Selecting 2,500 psi takes the A PRV out of the circuit by placing it into a loop, where it opens, but the flow is back into the incoming circuit. The B PRV, set to 2,500 psi, is in the circuit and operates identically to the A PRV valve circuit when using 2,000 psi operational mode.
The speed control pilot line also goes to the tank. The manual setting of the speed-control valve adjusts the speed of the Spinning Wrench for spinning in drill collars.
6-18 AR3200 SM00053, Rev D
July 1, 2005
Pressure
Filter
50 PSID
Main PRV
2000 PSI
2500 PSI
Speed Control
Spin Valve
Tank
Figure 6-1. Pressure-reducing valve circuit
SM00053, Rev D Troubleshooting 6-19
Troubleshooting mechanical components
LIFT CYLINDER CIRCUIT
The lift cylinder circuit hydraulic fluid flows through the check valve of the counterbalance manifold and to the rod end of the lift cylinders, causing the carriage and the torque wrench to rise (Figure 6-2).
To lower the torque wrench, actuate the valve to the lower position. Hydraulic fluid flows through the valve, through a flow-control valve and to the blind end of the lift cylinders, lowering the carriage. As the carriage lowers, hydraulic pressure builds up on the rod side of the lift cylinder. This pressure opens the counterbalance valve, relieving the hydraulic pressure and allowing the carriage to lower.
Pressure
Tank
Figure 6-2. Lift cylinder circuit
6-20 AR3200 SM00053, Rev D
July 1, 2005
HORIZONTAL TRAVEL CIRCUIT
When the AR3200 travels in either direction with the solenoid valve deenergized, all hydraulic fluid flow stops on the motor side of the valve (Figure 6-3). To prevent shearing, since the motors are unable to turn, the AR3200 uses cross-port relief valves. As pressure builds up from the motor attempting to turn, the pilot opens the cross-port relief to the other side of the line. This also creates a braking effect, but allows movement if pressures become too great.
In 2,500 psi mode, the Decel valve is activated and flow to the motors is restricted, reducing the roughneck travel speed.
Figure 6-3. Horizontal travel circuit
Pressure
Tank
CrossportRelief
Foot Motors
Horizontal Travel Circuit
SM00053, Rev D Troubleshooting 6-21
Troubleshooting mechanical components
SPINNING WRENCH CLAMP CIRCUIT
In the Spinning Wrench clamp circuit (Figure 6-4), hydraulic pressure flows through a check valve. The check valve maintains full pressure on the clamp circuit with drops in supply pressure. Hydraulic fluid flows through the directional valve directly to the clamp cylinders.
Pressure
Tank
Figure 6-4. Spinning Wrench clamp circuit
6-22 AR3200 SM00053, Rev D
July 1, 2005
SPINNING WRENCH SPIN CIRCUIT
The Spinning Wrench spin circuit is a high-flow volume circuit. Hydraulic fluid flows from the main PRV through the speed-control valve to the spin valve, flow dividers, the four hydraulic motors and then to tank (Figure 6-5).
Pressure-reducing valve circuit (PRV) on page 6-17 contains information on speed control in 2,500 psi (slow) and 2,000 psi (fast and normal) modes.
Pressure Main PRV
2000 PSI
2500 PSI
Speed Control
Spin Valve
Tank
Figure 6-5. Spinning Wrench spin circuit
SM00053, Rev D Troubleshooting 6-23
Troubleshooting mechanical components
TILT CYLINDER CIRCUIT
In the tilt cylinder circuit, hydraulic pressure flows through a check valve (Figure 6-6). The check valve maintains full pressure on the tilt cylinder with drops in supply pressure. Hydraulic fluid flows through the directional valve directly to the tilt cylinder.
Tank
Pressure
Figure 6-6. Tilt cylinder circuit
6-24 AR3200 SM00053, Rev D
July 1, 2005
TORQUE WRENCH CLAMP CIRCUIT
When the AR3200 torque wrench clamp function energizes, hydraulic oil flows out of the B port to the blind end of the torque wrench clamp cylinder (Figure 6-7). This causes the cylinder to start stroking, resulting in pressure buildup on the rod side of the cylinder. The counterbalance valve in the return line prevents this pressure (flow) from going to tank. A check valve allows the hydraulic oil to flow into the B line, allowing a greater flow to fill the blind end of the clamp cylinder. This condition is known as “regenerative mode.”
When pressure builds up on the blind end of the cylinder, the counterbalance valve opens from pilot pressure of the upper clamp B line and allows the flow from the rod end of the cylinder to go to tank. The system applies 2,000 psi to the blind end of the clamping cylinder.
Soft clamp mode
The AR3200 has a soft clamp mode to safely hold the box while spinning in drill pipe. In the soft clamp mode, only the lower clamp solenoid energizes. Pressure (flow) only goes to the B line, applying force to the blind end of the cylinder. The rod end of the cylinder oil enters a regenerative mode. Because there is never enough force to open the counterbalance valve, the lower clamp stays in the regenerative mode. In this case, the clamping force is equal to the area of the cylinder, minus the area of the rod, multiplied by the pressure (2,000 psi).
Pressure
Torque Wrench Clamp Upper
Torque Wrench Clamp Lower
Figure 6-7. Torque Wrench clamp circuit
SM00053, Rev D Troubleshooting 6-25
Troubleshooting mechanical components
TORQUE CYLINDERS CIRCUIT
The AR3200 torque adjust circuit (Figure 6-8) operates by selecting the appropriate make or break solenoid. Selecting the break out solenoid provides full breakout torque by allowing the 2,000/2,500 psi to flow to the blind end of the cylinders. It applies full torque because there is no control on the blind end of the cylinder.
In makeup mode, hydraulic flow first goes through a pressure-reducing valve that is set at maximum pressure. This PRV has an external port which, if left open to atmosphere, only allows about 100 psi of pressure to be generated through the PRV valve. By controlling this external port, an AR3200 operator can control the makeup pressure required for torquing the drill pipe connection.
The AR3200 also has another pressure-reducing valve on the external port of the PRV. Adjusting this valve allows adjusting the external port pressure, thus adjusting the pressure of the primary PRV. This allows achieving the torque required for makeup.
A dump valve on the external port, on the end-of-stroke, is used for makeup. When end-of-stroke is reached in the makeup mode, the valve actuates, releasing the pressure on the external port of the PRV. The AR3200 uses this signal for another restroke during an automatic sequence.
Tank Remote Adjust
Set at Max
Pressure
Figure 6-8. Torque cylinders circuit
6-26 AR3200 SM00053, Rev D
July 1, 2005
DIRECTIONAL VALVES
The AR3200 contains the following directional valves:
❏ Solenoid-operated, 2-position, 4-way (spring offset) (page 6-28)
❏ Solenoid-operated, three-position, four-way (spring-centered), float center (page 6-29)
❏ Solenoid-controlled, pilot-operated, 3 position, 4-way (spring-centered), float center (page 6-30)
About directional solenoid-controlled valves
Four-way directional valves contain a cylindrical piece called a spool, which slides in a machined bore in the valve housing. The housing has a number of ports to which the pressure, tank, and working lines for the actuator are connected. Internally, the ports are connected to cast or machined passages in the valve housing, which terminate at the machined bore where the spool is located. The axial movement of the spool in the bore determines which ports are connected together.
A manual override button is located on the end of the solenoid housing. Pressing this button performs the same function as the solenoid coil by manually shifting the spool against the spring. This valve is a manifold-mounted valve in that the ports are all located on the valve mounting surface and are equipped with O-ring face seals.
General diagnostic procedure for solenoid-controlled valves
A problem with this type of valve is usually related to improper shifting of the spool. For example, the spool doesn’t shift when the solenoid is energized, the spring doesn’t return or hold the spool offset when the solenoid is deenergized, or the spool does not shift fully in one or both directions. The most common cause of a stuck spool is particulate contamination of the hydraulic fluid. (See Hydraulic Fluid Cleanliness, SM00081, in the Supplemental Materials chapter.)
The other type of potential failure is an O-ring failure at the mounting surface, but the external leakage of hydraulic fluid makes this easy to detect. The detection procedure assumes there is no electrical problem; i.e., the coil is drawing the proper amount of current when energized.
SM00053, Rev D Troubleshooting 6-27
Troubleshooting mechanical components
Isolating a faulty solenoid-operated directional valve
To isolate the valve:
1. Verify that supply pressure (usually 2,500 psi) is available at the pressure port of the valve by connecting a test gauge to the appropriate test point. If the required pressure is not present, the valve is probably not the problem. Check for problems upstream of the supply port.
2. Using a test gauge on the test points for the A and B work ports, verify that a change in state occurs on the work ports when the valve is cycled. The valve can be actuated either electrically or by using the manual override button on the solenoid housing. If the manual override button is used, the coil should be in the deenergized state. With a normally operating valve, the pressure at a work port should alternate between a relatively low value and a much higher value, with the opposite value at the opposite work port. If no change of state is present, the spool is probably stuck in one position. (See Repairing a stuck spool to correct the problem.)
3. Using a test gauge on the test points for the A and B work ports, verify that the pressure at each work port equalizes with the supply pressure measured in step 1. You may have to wait for an actuator to move to its end of stroke before the pressure can stabilize. If the pressure does not stabilize, the valve is probably not the problem. There may be an internal leak somewhere downstream of the valve.
Repairing a stuck spool
To repair a stuck spool:
1. Try to free the spool by pressing on the manual override button, or apply a light tapping action on the body of the valve.
It may help to turn off the HPU (or press the EMERGENCY STOP button on the operator’s console) while performing step 1.
2. If performing step 1 doesn’t free the spool, remove the valve to expose the spool through its ports. Clean the area around the valve before removing it to prevent contamination of the exposed sealing surfaces and passageways.
3. Attempt to free the spool using a screwdriver in between the lands of the spool. (Do not pry on the outside diameter of the spool.)
4. If the spool appears to move freely when the manual override button is pressed, lubricate the inside of the valve with a light mineral based oil and remount the valve.
If you cannot free the spool, or the problem reoccurs, replace the valve.
6-28 AR3200 SM00053, Rev D
July 1, 2005
Two-position, solenoid-operated, four-way, (spring offset)
Function
This valve is identified on hydraulic schematic drawings using the following symbol:
The two-position, solenoid-operated, four-way directional valve directs hydraulic fluid between one of two flow paths. The flow path selection is determined by the presence or absence of electrical current in the single solenoid coil. This valve is a low-flow valve and supplies hydraulic fluid to small actuators. Or, this valve may be used as pilot operator for larger valves.
Theory of operation
The valve contains a spool held in one of two positions by a spring. In this position, the P (pressure) port is connected to the A working port and the B working port is connected to the T (tank) port.
A solenoid is located at the end of the spool opposite the spring. If the coil is energized, the solenoid armature moves the spool through a push pin, enough force is generated to overcome the spring, and the spool shifts in the housing. In this position, the P port is connected to the B working port, and the A working port is connected to the T port. When the solenoid coil is deenergized, the spring returns the spool to its original position.
Diagnostic procedure
See Isolating a faulty solenoid-operated directional valve on page 6-27.
aA B
P T
2 Position, Solenoid-Operated Valve,4 Way (Spring Offset)
SM00053, Rev D Troubleshooting 6-29
Troubleshooting mechanical components
Three-position, solenoid-operated, four-way (spring-centered), float center
This valve is identified on hydraulic schematic drawings using the following symbol:
Function
The three-position, solenoid-operated, four-way (spring-centered), directional valve directs hydraulic fluid to one of three possible flow paths. The flow path selection is determined by the presence or absence of electrical current in the two solenoid coils. This low-flow valve supplies hydraulic fluid to small actuators. Or, it can be used as pilot operator for larger valves.
Theory of operation
The valve contains a spool held in one of two positions by springs. In this position, the P (pressure) port is blocked and both the A and B ports are connected to the T (tank) port. Solenoids are located at either end of the spool. If one of the coils is energized, the solenoid armature moves the spool through a push pin, enough force is generated to overcome the spring and the spool shifts in the housing. In this position, the P port is connected to the B working port, and the A working port is connected to the T port. When the “a” solenoid coil is deenergized, the spring returns the spool to its center position.
When the “b” solenoid coil is energized, enough force is generated to overcome the spring and the spool will shift in the housing. In this position, the P port is connected to the A working port and the B working port is connected to the T port. When the “b” solenoid coil is deenergized, the spring returns the spool to its center position.
Diagnostic procedures
See Isolating a faulty solenoid-operated directional valve on page 6-27.
a bA B
P T
3 Position, Solenoid-Operated Valve,4 Way (Spring Centered), Float Center
6-30 AR3200 SM00053, Rev D
July 1, 2005
Three position, pilot-operated, solenoid controlled, four-way (spring-centered), float center
The valve is shown here in a typical circuit and as identified on hydraulic schematic drawings.
Function
The three-position, pilot-operated, solenoid controlled, four-way directional control valve directs hydraulic fluid between one of three flow paths. The presence or absence of sufficient hydraulic pressure acting on the two pilot pistons determines the selection of flow path. This valve normally handles medium to large flows and is controlled by a small, solenoid-operated, four-way pilot valve.
A B
P T
3 Position, Pilot-Operated Directional Control Valve,Solenoid-Controlled, 4 Way (Spring Centered),
Float Center, Typical Circuit
a
x y
bA B
P T
x yA B
P T
Pilot-Operated Valve,4 Way (Spring Centered), Float Center
SM00053, Rev D Troubleshooting 6-31
Troubleshooting mechanical components
Theory of operation
This valve consists of a pilot-operated main valve with a solenoid-operated pilot valve directly coupled, hydraulically and mechanically, to the main valve. The pilot valve takes its pressure supply and directs its return flow through the main valve. Similarly, the two working ports (A and B) of the pilot valve are connected to the pilot pistons of the main valve through internal passages in the main valve. the main valve has provisions to allow the supply pressure for the pilot valve to come from an external source (the x port). An internal plug is used to isolate the pressure supply of the main valve in this case. a similar port (the y port) exists for external pilot drain (return).
Diagnostic procedures
See Isolating a faulty solenoid-operated directional valve on page 6-27.
6-32 AR3200 SM00053, Rev D
July 1, 2005
LOAD-HOLDING VALVES
This section describes the load-holding valves contained in the AR3200.
Counterbalance valve, pilot assisted
The valve is shown here in a typical circuit and as identified on hydraulic schematic drawings.
Weight
CounterbalanceValve
Counterbalance Valve - Typical Circuit
P T
Counterbalance Valve
Free-flowCheck Valve
Major BiasSpring Adjustment
Cylinder Port
Valve Port
Pilot AssistPort
SM00053, Rev D Troubleshooting 6-33
Troubleshooting mechanical components
Function
The counterbalance valve with pilot assist is used for overrunning load control and hydraulic load locking. These valves restrict flow out of a hydraulic cylinder or motor to prevent cavitation, or formation of a partial vacuum. (Such cavitation can occur if the load causes the actuator to move faster than the supply coming from the pump.) The counterbalance valve locks the loaded actuator in place, should the hydraulic line of the actuator break, and also provides relief protection if the actuator is driven by an external force.
Theory of operation
Circuits using counterbalance valves use a directional control valve that connects the working ports A and B to the tank in the center position. This type of directional valve allows the best control and positioning of the load and provides an unrestricted path to the tank for any oil displaced when the counterbalance valves act as reliefs. As illustrated in the counterbalance valve symbol, counterbalance valves respond to pressure from two different sources. These are the pressure induced by the load acting on the cylinder or motor and the pressure at the pilot assist port. The forces generated by pressure at these two ports open the valve when the sum of the two forces is high enough to overcome the major bias spring (valve pressure setting). The reverse free flow check valve permits a free flow of fluid toward the actuator in the reverse direction of operation.
Diagnostic procedure
This valve can fail in either the open or closed position. If it fails while open, the load causes the actuator to drift over time. If the actuator appears to be drifting, troubleshooting consists of verifying that the valve has, indeed, failed in the open position and that it is not open due to incorrect adjustment or being piloted open.
If the valve fails while closed, actuator movement is impaired in the protected direction (i.e., opposite the free flow direction). Blocked flow across the check valve in the free flow direction is unlikely because of the large forces available to move the valve stem in this direction.
6-34 AR3200 SM00053, Rev D
July 1, 2005
To isolate a faulty load-holding valve:
1. If the actuator holds its position when the direction controlling valve is in neutral and the actuator is not at the end of its travel, proceed to step 4.
2. Measure the pressure at the pilot assist port. With the actuator's control valve in the center (neutral) position, the pilot pressure should be relatively low, usually less than 100 psi. Higher pressures may allow the valve to open, so check for a failure in the part of the circuit related to the pilot assist port.
3. If the pilot pressure measured in step 2 is normal (less than 100 psi), try increasing the valve pressure setting by turning the adjusting screw counterclockwise. If the load continues to drift, contamination may be preventing the valve from closing. Remove the valve and replace it with a new one.
4. Activate the control valve in the direction that will cause pressure to be applied to the pilot assist port. If the actuator does not move, measure the pressure at the pilot assist port while the control valve is actuated. With no load induced pressure acting on the valve, 800 psi at the pilot assist port should open the valve and allow the actuator to move. Higher load induced pressures reduces the required pilot pressure by approximately 30 psi for every 100 psi acting directly on the valve's cylinder port. If the required amount of pilot pressure is present and the actuator does not move, reduce the pressure setting by turning the adjusting screw clockwise. If this does not correct the problem, replace the valve.
SM00053, Rev D Troubleshooting 6-35
Troubleshooting mechanical components
Relief valve, pilot-operated
The relief valve is identified on hydraulic schematic drawings using the following symbol.
Function
The pilot-operated relief valve smoothly regulates maximum system pressure in a hydraulic system or subsystem over widely varying flow conditions.
Theory of operation
A pilot-operated relief valve consists of two sections: the main valve and a pilot section. The main valve contains inlet and outlet ports, a spool with an orifice in the center, and a spool bias spring.
The pilot section consists of a small capacity, direct-acting, relief valve with a screw adjustment. The pilot supply orifice in the piston end of the main spool connects the inlet of the valve to the bias spring cavity. The areas of the piston at the inlet and in the spring cavity are essentially equal, so the pressure/area forces on the main spool are in balance. If fluid entering through the pilot supply orifice cannot escape, the piston is in hydraulic balance and the bias spring holds the spool in the closed position, blocking the passage from inlet to return.
The small capacity, direct acting, relief valve is held in position by the adjustable pilot spring. This pilot spring establishes the pressure level at which the inlet pilot flow will be directed to a lower pressure level - return to tank. When pressure in the bias spring cavity is high enough to open the small relief, fluid flows from the cavity to the return. This flow creates a pressure differential across the orifice. When this pressure differential is high enough to overcome the force of the bias spring, the piston opens and creates a large flow path from the inlet to return to tank.
Inlet
Outlet(Tank)
Bias Spring(Adjustment)
Pilot-Operated Relief Valve
6-36 AR3200 SM00053, Rev D
July 1, 2005
Diagnostic procedure
If a problem occurs with this component, it is usually that it relieves at too low a pressure, or that it does not relieve at all.
To isolate a faulty relief valve:
1. If the relief valve opens at a pressure below what is expected, measure the differential pressure across the valve (the difference in pressure between the valve’s inlet and outlet ports) and compare it to the required setting. Increase the valve setting as required.
Turning the adjustment screw in (clockwise) increases the setting of the valve. If the valve stays open regardless of the setting and/or differential pressure across the valve, it is probably stuck open and should be replaced.
2. If the valve opens at too high a pressure or does not open at all, measure the differential pressure across the valve (the difference in pressure between the valve’s inlet and outlet ports) and compare it to the required setting. Decrease the valve setting as required.
Turning the adjustment screw out (counterclockwise) decreases the setting of the valve. If reducing the valve set point still does not allow the valve to open, it may be stuck and should be replaced.
SM00053, Rev D Troubleshooting 6-37
Troubleshooting mechanical components
Check valve, pilot-operated
The valve is shown here in a typical circuit and as identified on hydraulic schematic drawings.
Function
The pilot-operated check valve positively locks a pressurized load, but releases the load upon application of a pressure signal at the pilot port. This valve is normally used to lock an actuator in position when the directional valve is centered (neutral). The valve is used in applications where overrunning load control and/or a relief function is not needed or is provided by other means.
Weight
Pilot-OperatedCheck Valve
Pilot-Operated Check Valve,Typical Circuit
P T
Cylinder Port
Pilot-Operated Check Valve
Valve Port
Pilot Port
6-38 AR3200 SM00053, Rev D
July 1, 2005
Theory of operation
A pilot-operated check valve consists of a valve body with inlet and outlet ports and a poppet held against a seat by a spring, as in an ordinary check valve. Directly Opposite the check valve poppet is a plunger and a plunger piston, which is biased by a light spring. Pilot pressure is sensed at the plunger piston through the pilot port. The valve allows free flow from its inlet port to its outlet port like an ordinary check valve. Fluid flow attempting to pass through the valve from the outlet port to the inlet port forces the poppet onto its seat, blocking flow through the valve. When enough pilot pressure is sensed at the plunger piston, the plunger moves and unseats the check valve, allowing fluid to pass. The ratio of the load pressure to the pilot pressure required to release the load is called the pilot ratio.
Diagnostic procedure
If this valve fails, usually it is in the open position. That is, the valve does not positively lock the pressurized load. If the valve fails closed, in the free flow direction, severe contamination or damage to the internal sliding surfaces probably exists.
To isolate a faulty pilot-operated check valve:
1. If the valve does not pass flow in the free-flow direction, measure the pressure on both sides of the valve using test gauges. If the upstream pressure is significantly higher than the downstream pressure, the valve is probably stuck closed and should be replaced.
2. If the valve does not lock the pressurized load with the directional valve centered, measure the pressure at the pilot port. This pressure should be relatively low (usually less than 100 psi). Higher pressures may allow the valve to open, so check for a problem with the part of the circuit connected to the pilot port.
3. If the pressurized load cannot be released, check the pressures at both the pilot port and the outlet port (the port connected to the actuator). If the pilot pressure is greater than the actuator pressure divided by the pilot ratio (usually 3:1), the valve should open. If it does not, replace the valve.
SM00053, Rev D Troubleshooting 6-39
Troubleshooting mechanical components
PRESSURE CONTROL VALVES
Pilot-operated, pressure-reducing valve
The valve is shown here in a typical circuit and as identified on hydraulic schematic drawings.
Function
The pilot-operated, pressure-reducing valve regulates pressure in a hydraulic circuit.
W
Control Cover
Hydrostat Insert
Fixed Orifice (Proportional Valve)
Pilot-Operated Pressure Reducing ValveTypical Circuit
Inlet
OutletPilot-Operated Pressure Reducing Valve
Pilot Drain
Bias Spring(Adjustment)
6-40 AR3200 SM00053, Rev D
July 1, 2005
Theory of operation
The pilot-operated, pressure-reducing valve consists of two sections: the main valve and a pilot section. The main valve contains inlet (nonregulated pressure) and outlet (regulated pressure) ports, a spool with an orifice in the center, and a spool bias spring.
The pilot section consists of a small-capacity, direct-acting, relief valve with a screw adjustment. The orifice in the spool connects the regulated pressure of the valve to the bias spring cavity. The areas of the spool at the inlet and in the spring cavity contain equal pressure, so the forces on the main spool are in balance. When fluid enters through the pilot supply orifice (the relief valve is closed), the fluid cannot escape. A hydraulic balance exists, and the bias spring holds the spool in the open position, allowing full flow from inlet to return.
The screw adjustment compresses the pilot spring, which establishes the pressure level at which the pilot flow ends up at a lower pressure (drain). When pressure in the bias spring cavity is high enough to open the small relief valve, fluid flows from the cavity to return. This flow creates a pressure differential across the orifice. When this pressure differential is high enough to overcome the force of the bias spring, the spool begins to close, creating a restriction in the flow path. This restriction limits the flow from the inlet to the outlet to a value which maintains the selected reduced pressure in the outlet portion of the circuit.
Any pressure at the drain port is additive to the pressure setting of the valve. This characteristic can be used to implement remote control of the valve.
Diagnostic procedure
Usually, if the pressure-reducing valve fails, it fails to close down. Hence, the valve does not provide the required pressure reduction.
To isolate a faulty pilot-operated pressure-reducing valve:
1. If the outlet pressure is too high, try reducing the setting of the valve by turning the adjusting screw out (counterclockwise) while observing the pressure at the outlet port. If this procedure does not reduce the pressure to the desired level, measure the pressure at the pilot drain port. If this pressure is higher than the desired set point, a condition exists in the pilot drain circuit that prevents the pressure-reducing valve from being adjusted lower. Correct this problem and then readjust the valve.
2. If the pilot drain pressure measured in step 1 is below the desired valve setting and the valve will not adjust lower, the spool may be stuck and the valve should be replaced.
SM00053, Rev D Troubleshooting 6-41
Troubleshooting mechanical components
AUXILIARY VALVES
Check valve, pilot-to-close
This valve is identified on hydraulic schematic drawings using the following symbol:
Function
The pilot-to-close check valve allows flow in one direction only but prevents flow in the free-flow direction upon application of sufficient pressure at the pilot port. This valve normally locks an actuator in position when the directional valve is centered (neutral). The valve is used in applications where multiple functional modes are required, such as for regenerative circuits.
Theory of operation
A pilot-to-close check valve consists of a valve body with inlet and outlet ports and a poppet, which is held against a seat by a spring, as in an ordinary check valve. Directly opposite the check valve poppet is a pilot piston. The pilot piston and the poppet are held apart by a light spring. Pilot pressure is sensed at the pilot piston through the pilot port.
The valve allows free flow from its inlet port to its outlet port. Fluid flow attempting to pass through the valve from the outlet port to the inlet port forces the poppet onto its seat, blocking flow through the valve. When enough pressure is present at the pilot piston, the piston moves against the poppet, preventing flow in either direction. The ratio of the load pressure to the pilot pressure required to lock the load is called the pilot ratio.
Inlet
OutletPilot Port
Check Valve, Pilot to Close
6-42 AR3200 SM00053, Rev D
July 1, 2005
Diagnostic procedure
If this valve fails, it usually fails in the open position. That is, the valve allows flow in both directions. If the valve fails closed, in the free-flow direction, severe contamination or damage to the internal sliding surfaces probably exists.
To isolate a faulty check valve:
1. If the valve does not pass flow in the free-flow direction, measure the pressure on both sides of the valve using test gauges. If the upstream pressure is significantly higher than the downstream pressure, the valve is probably stuck closed and should be replaced.
2. If the valve does not block flow from the outlet to the inlet, measure the pressure at the inlet and outlet ports of the valve. If the pressure on the outlet is higher than at the inlet, remove the valve and check for damaged seals and replace as necessary. If the seals are not damaged, the poppet is probably stuck open due to contamination and the valve should be replaced.
3. Perform this step if the valve does not appear to block flow in the free-flow direction when piloted closed. Measure the pressure at the pilot and inlet ports. If the pilot pressure is at least 1.8 times the inlet pressure, flow in the free flow direction should be prevented. If it is not, remove the valve and check for damaged seals and replace as required. If the seals are not damaged, the poppet is probably stuck open due to contamination and the valve should be replaced.
z Any pressure at the outlet port reduces the required pilot ratio to values below 1.8.
SM00053, Rev D Troubleshooting 6-43
Troubleshooting mechanical components
Check valve
This valve is identified on hydraulic schematic drawings using one of the following symbols:
Function
The check valve allows flow in one direction only.
Theory of operation
A check valve consists of a valve body with inlet and outlet ports and a poppet held against a seat by a spring. The valve allows free flow from its inlet port to its outlet port when the differential pressure between the inlet and outlet is greater than the “cracking pressure” of the valve. The cracking pressure is determined by the strength of the spring and the areas exposed to the differential pressure across the valve. Fluid flow attempting to pass through the valve from the outlet port to the inlet port forces the poppet onto its seat, blocking flow through the valve.
Diagnostic procedure
If this valve fails, it is usually in the open position. That is, the valve permits flow in both directions. If the valve fails closed, in the free flow direction, severe contamination or damage to the internal sliding surfaces probably exists.
To isolate a faulty check valve:
1. If the valve does not pass flow in the free flow direction, measure the pressure on both sides of the valve using test gauges. If the upstream pressure is higher than the downstream pressure by an amount at least 50 psi greater than the cracking pressure, the valve is probably stuck closed and should be replaced.
2. If the valve does not block flow from the outlet to the inlet, measure the pressure at the inlet and outlet ports of the valve. If the pressure on the outlet is higher than at the inlet, remove the valve, check for damaged seals and replace as necessary. If the seals are not damaged, the poppet is probably stuck open due to contamination and the valve should be replaced.
Inlet
Outlet
Inlet
Check Valve
Outlet
6-44 AR3200 SM00053, Rev D
July 1, 2005
FLOW VALVES
This section describes troubleshooting various types of flow valves.
Orifice
This component is identified on hydraulic schematic drawings using the following symbol:
Function
Orifices are used in hydraulic circuits to provide a known restriction in a flow path.
Theory of operation
An orifice is a relatively small opening in a fluid’s flow path. For a given fluid type, the flow rate through an orifice is affected by the diameter of the orifice, the pressure differential across the orifice, and the temperature of the fluid. Common examples of fixed orifices used in hydraulics are threaded plugs or check valves with a hole drilled through their centers.
Diagnostic procedure
This component fails to perform if it becomes plugged, either fully or partially, by contamination. If a circuit that includes an orifice is not performing properly, remove and clean the orifice.
Orifice
SM00053, Rev D Troubleshooting 6-45
Troubleshooting mechanical components
Pressure-compensated, fixed orifice
This component is identified on hydraulic schematic drawings using the following symbol:
Function
This flow-control valve uses a fixed orifice to control the flow rate in a circuit. The valve is pressure-compensated to provide constant regulated flow, regardless of load variations. The flow rate is factory set by means of a fixed orifice. This valve is capable of reverse, noncompensated flow equal to the flow setting (orifice size).
Theory of operation
This valve consists of a body with an inlet and outlet, a compensator spool with a fixed orifice and a spring. Flow passes through the orifice in the center of the compensator spool, then out the side of the spool through a series of radially located holes. The valve body also contains a series of radially located holes in the area of the outlet port.
The compensator spool senses both the incoming pressure and the load pressure and moves to restrict the flow through the two sets of holes, maintaining a constant pressure drop across the orifice. This movement causes the valve to maintain a constant flow output, regardless of variations in the upstream or downstream pressure. Reverse flow from the outlet to the inlet causes the compensator spool to move all the way to one side, fully opening the two sets of holes to the outlet port. Only the fixed orifice acts to regulate the flow and is, therefore, not pressure-compensated.
Flow Control Valve,Pressure Compensated,
Fixed Orifice
6-46 AR3200 SM00053, Rev D
July 1, 2005
Diagnostic procedure
This component fails to perform when the orifice becomes plugged or the compensator spool sticks because of contamination.
To check this component:
1. If the valve allows too much flow to pass in the controlled direction, remove it and check for damaged seals and replace as required. If the seals are not damaged, the compensator spool or the check function may be stuck open by contamination and the valve should be replaced.
2. If the valve does not allow enough flow to pass in the controlled direction, the orifice may have become plugged. Remove the valve, check for contamination, and clean it. If this does not solve the problem, the compensator spool may be stuck closed by contamination and should be replaced.
SM00053, Rev D Troubleshooting 6-47
Troubleshooting mechanical components
Flow control valve, adjustable, pressure compensated, full reverse free flow
This component is identified on hydraulic schematic drawings using the following symbol:
Function
This flow-control valve uses a variable orifice spool to control the flow rate in a circuit. The valve is pressure compensated to provide constant regulated flow regardless of load variations. The flow rate is adjustable by means of a threaded screw. This valve is capable of full reverse, noncompensated flow, regardless of the flow setting.
Theory of operation
This valve consists of a body with an inlet and outlet, a compensator spool with a fixed orifice, and a bias spring. It also contains a smaller spring to provide full reverse free flow. Flow must pass through the orifice in the center of the compensator spool and then out the side of the spool through a series of holes that are radially located. The valve body also has a series of radially located holes in the area of the outlet port. A second set of holes in the valve body in conjunction with an annular groove on the outside of the compensator spool allows for full reverse free flow.
The compensator spool senses both the incoming pressure and the load pressure and moves to restrict the flow through the two sets of holes maintaining a constant pressure drop across the orifice. This causes the valve to maintain a constant flow output, regardless of variations in the upstream or downstream pressure. The value of the bias spring adjustment controls the maximum compensated flow through the valve. Reverse flow from the outlet to the inlet causes the compensator spool to move against the small spring all the way to one side connecting the inlet to the outlet through the second set of holes in the valve body in conjunction with the annular groove on the outside of the compensator spool.
Flow Control Valve, Adjustable, Pressure-Compensated, Full-Reverse Free Flow
6-48 AR3200 SM00053, Rev D
July 1, 2005
Diagnostic procedure
This component fails to perform if the orifice becomes plugged or the compensator spool sticks because of contamination. (See Diagnostic procedure for Flow control valve, adjustable, pressure compensated, full reverse free flow on page 6-47.)
SM00053, Rev D Troubleshooting 6-49
Troubleshooting mechanical components
Output actuators
HYDRAULIC CYLINDERS
This section describes troubleshooting procedures for hydraulic cylinders. Hydraulic cylinders are identified on hydraulic schematic drawings using the following symbols:
Function
The hydraulic cylinder converts hydraulic energy into straight-line mechanical energy. A hydraulic cylinder can also be used to hold and lower a load against gravity forces, with the addition of suitable hydraulic circuitry.
Theory of operation
A hydraulic cylinder consists of a cylinder body, a movable piston, and a piston rod attached to the piston. End caps attach to the cylinder body barrel by threads, tie rods, or a weld. The end through which the rod extends is called the “head” (or “rod”) end; the opposite end is called the “cap” (or “blind”) end. Each end cap contains a port that allows fluid to enter and exit that end of the cylinder. As the cylinder rod moves in and out, it is guided and supported by a removable bushing called a rod gland or rod bearing. The rod gland contains a piston rod wiper and a primary seal. The piston is equipped with one or more primary seals and, in some cases, wear rings.
Single Rod Cylinder Double Rod Cylinder
Hydraulic Cylinders
Tandem Cylinder
6-50 AR3200 SM00053, Rev D
July 1, 2005
Diagnostic procedure
A hydraulic cylinder problem is usually related to the cylinder not producing the required push or pull force. If the fault is with the cylinder, and not its related hydraulic circuitry, the fault is likely being caused by internal or external leakage of the pressurized fluid. External leakage is easy to detect and is not dealt with here.
If the piston seals fail, fluid from the high pressure side of the piston passes to the low pressure side, which is generally connected to tank through a directional valve. If this leak is large enough, the hydraulic power unit cannot maintain the pressure at the intended level. If the cylinder is supporting a gravity load, internal leakage may allow the rod to extend or retract until end of stroke is reached.
Internal seal failure
To troubleshoot an internal seal failure, you should determine if the cylinder can hold pressure over time.
To diagnose a hydraulic cylinder problem:
1. If the cylinder is required to support a gravity load and is not holding its position, verify that the related load-holding valves are functioning properly. (See Load-holding valves on page 6-32.)
2. Attach a test gauge to the appropriate test point in the line for the cylinder in question. Actuate the appropriate directional valve and observe the pressure as the cylinder strokes. When the cylinder reaches end of stroke, the reading should rise and stabilize at the supply pressure value.
In diagnosing, it may help to operate only a single pump and use the slowest speed available for the function. A faulty piston seal can prevent the pressure from stabilizing.
You may hear the flow of the oil leaking across the piston. If so, replace the piston seals.
SM00053, Rev D Troubleshooting 6-51
Troubleshooting mechanical components
HYDRAULIC MOTORS
Hydraulic motors are identified on hydraulic schematic drawings using the following symbol:
Function
The hydraulic motor converts hydraulic energy into rotary mechanical energy.
Theory of operation
Hydraulic motors operate by causing an imbalance that results in the rotation of a shaft. A Geroler motor is a type of internal gear motor with an inner drive gear and an outer drive gear with one more tooth than the inner gear. The inner gear is attached to a shaft connected to the load. The outer gear in a geroler motor consists of several rollers held in place by a slotted ring. The imbalance in this type of motor is caused by the difference in gear area exposed to hydraulic pressure at the motor inlet. The exposed area of the inner gear increases at the inlet. Fluid pressure acting on these unequally exposed teeth results in a torque at the motor shaft. Larger gears or higher pressures create higher torques at the output shaft. A cylindrical porting ring directs fluid between the inlet and outlet ports and the rotating group through passages in the motor housing. A case drain is sometimes provided to protect the shaft seals from damage due to internal motor leakage. Hydraulic motors are identified on hydraulic schematic drawings using the following symbol:
Case Drain
Hydraulic Motor
6-52 AR3200 SM00053, Rev D
July 1, 2005
Diagnostic procedure
A problem with this component is usually related to a loss of output torque due either to internal binding or to excessive internal leakage. Perform the following steps to check the motor:
1. If the motor fails to rotate freely when not under load or excessive heat or noise is generated, internal damage has occurred, and the motor should be replaced.
2. To check for excessive internal leakage, operate the motor in a stalled condition. Check the pressure at both the inlet and outlet ports of the motor. The inlet pressure should be very near the supply pressure for this circuit, normally 2,500 psi. The pressure at the outlet port should be near that of the tank pressure, less than 100 psi. If this is not the case, or excessive flow across the stalled rotor is evidenced by heat or noise, replace the motor.
SM00053, Rev D Troubleshooting 6-53
T
Troubleshooting electrical and control system components
Causes of malfunctionThe most common causes of control system malfunction are
❏ Lack of hydraulic pressure or
❏ Electrical supply voltage
The AR3200 PLC control boxes are located remotely from the tool. Interconnection is through service loops that run from the tool J-box to the derrick J-box and through rig wiring to the PLC. Numerous wire runs and connections that interconnect the AR3200 and the PLC must be properly marked and terminated to avoid improper wiring and high resistance.
z Improper interconnection wiring is another common cause of control system malfunction.
AR3200 control systemThe AR3200 control system consists of control loops made up of combinations of a few basic types of components.
Figure 6-9 illustrates a typical control loop.
Inputs from the operator and feedback on machine movement are directed into the Programmable Logic Controller (PLC). The PLC also initiates the system's outputs.
Troubleshooting a problem with the control system involves determining which of the control system components has failed. Each PLC input and output has an associated diagnostic indicator showing each component's current state. Upon indication of AR3200 equipment failure, use the general troubleshooting flow chart illustrated in Figure 6-10 to help isolate the problem. Follow the appropriate diagnostic procedures to check the AR3200 components and consult the corresponding troubleshooting tables.
6-54 AR3200 SM00053, Rev D
July 1, 2005
Operator Inputs
OUTPUTFUNCTION
PLC Output CardOutput Device
Test Point
PLC CPU
CONTROLSOFTWARE
INTERLOCKROUTINE
OUTPUTROUTINE
(Switches)
LED
PLC Input Card Feedback Device(Sensor)LED
Figure 6-9. Typical control loop
SM00053, Rev D Troubleshooting 6-55
AR3200 control system
TroubleShooting
Yes
No
Yes
No
Yes
No
Actuate InputSwitch
Is There ACommunication
Error?
Check OperatorInterface Hardware
IsInterlock On?
Check PLCHardware
Yes
NoDoes InterlockCondition
Exist?
Check InterlockCircuit
Operation isCorrect -
Clear InterlockCondition Before
Proceeding
Is OutputIndicator
On?
CheckOutput Device
Figure 6-10. Troubleshooting flow chart
6-56 AR3200 SM00053, Rev D
July 1, 2005
Troubleshooting the PLCThis section describes general procedures for diagnosing and troubleshooting the PLC. See also the Siemens manual and Figure 6-12 and Figure 6-13 for additional PLC troubleshooting information.
z The PLC configurations describes in this manual are typical, but not universal. See your Technical Drawings Book for rig-specific information.
❏ If a particular function on the tool is not working, determine if the PLC received the input and if the corresponding output was energized.
❏ If a control sensor is actuated and the input LED does not illuminate, check the devices (i.e., sensors and barriers) connected on the input side.
❏ If a control switch is actuated and the input LED does not illuminate, check the devices (i.e., switches and barriers) connected on the input side.
❏ If the output LED illuminates but the related output actuator does not function, check the devices (i.e., solenoid drivers) connected on the output side.
❏ If an input LED illuminates but the related output LED does not illuminate, either the PLC and/or its related hardware has failed, or an interlock condition exists. This applies to the manual mode only. When in a sequenced operation, not all input LEDs have corresponding output LEDs.
Replace any faulty PLC component upon detection.
LAST RESORT PLC TROUBLESHOOTING PROCEDURE
If you cannot bring the PLC into the RUN operating mode, the battery was probably installed or changed while power to the PLC was OFF. Use the following procedure to reset the PLC, load the software from the EPROM to the PLC, and return the PLC to the RUN operating mode:
1. Set the operating mode switch to STOP.
2. Remove the battery.
3. Set the ON/OFF switch to ON.
4. Set the RUN/STOP switch to RUN.
5. Install the battery.
Contact Varco if the above measures are ineffective.
6-57 AR3200 SM00053, Rev D
July 1, 2005
Figure 6-12. Siemens digital I/O module
6-58 AR3200 SM00053, Rev D
July 1, 2005
Table 6-6. S5-95U LEDs, controls, and interfaces
# Component Function
1 Battery compartment
2 Front panel connector For digital inputs (I 32.0 to I 33.7) and digital outputs (Q 32.0 to Q 33.7)
3 Battery low LED
4 ON/OFF switch
5 LED display for digital inputs and outputs
6 Terminals for connecting the power supply
7 SINEC L2 bus fault LED for S5-95U, Order Nos. 6ES5 095-8MB...; SINEC L2-DP bus fault LED for S5-95U, Order Nos. 6ES5 095-8MD...
8 Cable connector for S5-100U modules
9 RUN/STOP LEDs: Green LED --> RUN, Red LED --> STOP
10 Interface For analog inputs (IW 40 to IW 54) and for analog output (QW 40)
11 SINEC L2 interface for S5-95-U, Order Nos. 6ES5 095-8MB...;2nd serial interface for S5-95U, Order Nos. 6ES5 095-8MC...;SINEC L2-DP interface for S5-95U, Order Nos. 6ES5 095-8MD...
12 RUN/STOP/COPY switch
13 Receptacle for E(E)PROM submodule
14 Interface for a programmer, PC, OP, or SINEC L1 bus
15 Interface For interrupt inputs (I 34.0 to 34.3) and for counter inputs (IW 36, IW 38)
SM00053, Rev D Troubleshooting 6-59
AR3200 control system
12
3
45
6
7
8
9
10
11
12131415
Battery
L+
RUNSTOPCOPY
BF
RUN
STOP
DC 24VM
123456789
1011121314151617181920
ba 1234567891011121314151617181920
Figure 6-13. Siemens S5-95U LEDs, controls and interfaces
6-60 AR3200 SM00053, Rev D
July 1, 2005
Table 6-7. PLC LEDs
Manual Control Switch
PLC Box TB2
CPU Input LED
CPU Output LED
CableSolenoid driver
Function
UP 2 I32.0 Q32.0 C01 A-1 Carriage up
DOWN 3 I32.1 Q32.1 C02 A-2 Carriage down
WELL 4 I32.2 Q32.2 C03 A-3 Well center
HOME 5 I32.3 Q32.3 C04 A-4 Home
TW UNCLAMP1 10 I33.0 Q32.4 C05 B-1 TW upper jaws open TW CLAMP1 11 I33.1 Q32.5 C06 B-2 TW upper jaws close TW UNCLAMP1, 2 10 I33.0 Q32.6 C07 B-3 TW lower jaws open TW CLAMP1, 2 11 I33.1 Q32.7 C08 B-4 TW lower jaws close
SW UNCLAMP 8 I32.6 Q33.0 C09 C-1 SW arms open
SW CLAMP 9 I32.7 Q33.1 C10 C-2 SW arms close
TW MAKEUP 12 I33.2 Q33.2 C11 C-3 TW makeup
TW BREAKOUT
13 I33.3 Q33.3 C12 C-4 TW breakout
SW IN 6 I32.4 Q33.4 C13 D-1 Spin in
SW OUT 7 I32.5 Q33.5 C14 D-2 Spin out
TILT 15 I33.5 Q33.6 C15 D-3 Tilt
2,000/2,500 14 I33.4 Q33.7 C16 D-4 2500 psi
Automode 16 I33.6
MANUAL mode 17 I33.7
ESD switch 18
ESD switch 19
Autostart 20
TRIP IN 21 I65.0
TW BACKUP mode 22 I65.1
Spare 23 I65.2
Spare 24
1Both upper and lower jaws close/open. 2Only lower jaws close/open in TW backup mode.
SM00053, Rev D Troubleshooting 6-61
AR3200 control system
Sensor PLC Box TB1
CPU Input LED
PLC Box Check
PS-Mode SW 1, 2 I64.0 IS Barrier switches
TW position 4, 5 I64.1 IS Barrier switches
TJD proximity 7, 8 I64.2 IS Barrier switches
Horizontal index (slot) 10, 11 I64.3 IS Barrier switches
Horizontal position 13, 14 I64.5 IS Barrier switches
Flow SW 16, 17 I64.5 IS Barrier switches
EOS proximity 19, 20 IS Barrier switches
Vertical encoder 22, 23 25, 26 Zener safety barrier switches
Spinout proximity 28, 29 IS Barrier switches
TJ length SW 31, 32 VR 9.9-10.IV IS potentiometer driver
Switch PLC Box TB3
CPU Input LED
Drill cont. autostart 2 I65.3
TRIP IN 3 I65.4
Spare 4 I65.5
Drill Monitor station ESC
5, 6
REM IND1 7 Q64.0 (output)
REM IND2 8 Q64.1 (output)
-- 9 Q64.2 (output)
LEARN 64.6
Spare 64.7
6-62 AR3200 SM00053, Rev D
July 1, 2005
PLC POWER SUPPLY
The PLC power supply provides all internal PLC power requirements.
Theory of operation
The 115/230 V switch must be on 115 V. It generates an open-circuit output voltage of 24 VDC at 2A.
Diagnostic procedure
The front panel of the power supply contains several test points for diagnosing problems.
In case of any power supply fault indication, replace the power supply or battery.
DIGITAL INPUT/OUTPUT MODULE
The digital input/output module (Figure 6-12) converts the external discrete input signals to the internal signal level of the programmable controller. The module interfaces with all operator control switches and tool proximity switches.
Theory of operation
The input signals are first conditioned by input conditioning circuitry that suppresses any interference. Part of the input circuitry contains input status LEDs that provide visual indication of each input state. Each input on the module is galvanically isolated to 1,250 VAC and has a maximum signal input frequency of 100 Hz. Input signal voltage of 0 to 5 V is considered to be logic 0; 13 to 33 V is a logic 1. The modules require an enabling input voltage and power supply voltage.
SM00053, Rev D Troubleshooting 6-63
AR3200 control system
12
34
56
78
998
76
54
32
1
1
1
1
1
1
1
1
1
1
8
7
6
5
4
3
2
11
2
3
4
5
6
7
8
TB 7
715
764
A
B
C
D
4
5
TB 1
3
2
1
0
61
51
41
12
31
11
01
9
8
7
6
71
81
91
2
3
5
4
3
0
1
2
6
21
22
2 3
2 4
2 5
2 6
2 7
2 8
2 9
3
3
3
3
3
3
2
19
18
17
6
7
8
9
10
11
13
21
14
15
16
5
4
3
2
1
0
6
2
2
1
0
3
4
5
3
1
2 2
2 3
2 4
2 5
2 6
2 7
2 8
2 9
3
3
3
3
3
3
1
2
3
4
5
6
7
8
0
9
1
8
7
6
5
4
3
2
1
9
01
TB 3
1
2
3
4
5
6
7
8
9
0
11
2
3
4
5
6
7
32
22
12
02
9
8
42
8
7
6
5
4
3
2
1
1
9
0
11
1 2
1 3
1 4
1 5
1 6
71
32
22
12
02
19
81
2 4
TB 2TB 4
TB 5
1
9
0
8
7
6
5
4
3
2
1
10
9
1
2
3
4
5
6
7
8
1 8
91
2 0
2 1
2 2
1 7
61
51
41
31
21
11
01
9
8
7
6
5
4
3
2
1
1 8
91
2 0
2 1
2 2
1 7
61
51
41
31
21
11
0
9
1
1
2
3
4
5
6
7
8
TB 9
4
3
2
1
4
3
2
1
1
2
3
4
5
6 6
5
4
3
2
1
TB 6
5
6
7
88
7
6
5 1
1
5
5
MODULE D
98
76
54
32
1 12
34
56
78
9
MODULE C
12
34
56
78
9 98
76
54
32
11
23
45
67
899
87
65
43
21
MODULE A
MODULE B
SPARE
TEACH
OFF ON
ONOFF
TB 8
121114
42 12 22
A2A2A1
321 4
1 2 3 4
24V Power Supply Backup Battery CPU EPROM I/O Module PLC Box Assy
SolenoidDrivers
Kill Relay(ESD)
SolenoidDrivers
1AMPCircuitBreakers
5 AMPCircuit Breakers
Isolation Relay(BEBCO UL Purgeon Tool J-Box)
EncoderSafetyBarrier
ISPotentiometerDriver
12V PowerSupply(Encoder)
IS Terminal Blocks(Knife Switch Type)
Learn Mode Switch
ISAmplifier/Barrier
Figure 6-14. AR3200 PLC assembly and enclosure
6-64 AR3200 SM00053, Rev D
July 1, 2005
Diagnostic procedure
The basic diagnostic procedure of a defect is to replace the defective module.
Each input on the module contains an associated green input status LED that illuminates when an input voltage of 13 + 33 VDC is applied.
1. If a known input does not turn on the appropriate LED, check the voltage to the input terminal.
2. Using a Digital Volt Meter (DVM), place the positive lead on the appropriate module input terminal and the negative lead on terminal 21.
Verify that the measured voltage is 13 to 33 VDC.
3. If the input voltage is acceptable and the input LED is not on, the module is defective and should be changed.
4. If the input voltage is not acceptable, check the appropriate IS input module, switch, circuit, or power supply.
5. If known inputs exist on the module, and no input status LEDs are on, check the enable input voltage and/or module DC voltage supply.
6. Using a DVM, place the positive lead on terminal 1 and the negative lead on terminal 2.
Verify that the enabling voltage is 13 to 33 VDC.
SM00053, Rev D Troubleshooting 6-65
AR3200 control system
CONTROL SYSTEM INPUTS
Encoders
Encoders provide relative position measurements.
Theory of operation
The encoder contains a “glass” disc with 250 etched windows, an LED, and two photo-amplifiers with output transistors. As the disc rotates, the light from the LED passes through the etched windows where the photo-amplifier sense it, turning on their appropriate output transistors. This produces two square wave signals, channel A and B. The photo-amplifiers are precisely positioned so that channel B output leads channel A by 90o when the encoder shaft rotates clockwise (as viewed from the shaft end). The encoders are certified intrinsically safe (IS) when used with appropriate Zener safety barriers; these barriers are contained within the PLC assembly enclosure.
Diagnostic procedure
1. At the encoder terminals, measure the IS Voltage source at terminal 1 with respect to terminal 4 (0 V side). Verify that the voltage is approximately 5.0 to 6.0 V. If no voltage is present, or if it is significantly out of range, check the appropriate field terminals, Zener barrier, and encoder voltage source located in the control enclosure.
2. The following procedure is used to verify channel A and B outputs. (Note: The encoder shaft gear may require removal.)
❏ Measure the voltage at terminal 2 with respect to terminal 4 (0 volt side) for channel A and terminal 3 with respect to terminal 4 (0 volt side) for channel B. The voltage should change from 12 + 1 V to 0.7 + 0.5 V as the encoder shaft is slowly rotated. (Note: There are 250 transitions for each full rotation of the shaft.) Failure to detect a 12 V pulse level indicates an encoder device failure or possible field terminal or Zener barrier failure. Detecting a constant 0.7 V level indicates a barrier failure.
6-66 AR3200 SM00053, Rev D
July 1, 2005
PROXIMITY SENSORS
Proximity sensors provide the information necessary to determine relative tool positions and also provide an absolute position for determining physical positions (index). They also provide input data and detect spinout completion.
Theory of operation
The proximity sensor employs a 2-wire technique known as NAMUR and meets DIN 19234 for intrinsic safety. The system proximity sensors are similar to standard DC and AC inductive proximity sensors that normally include an oscillator, amplifier, and trigger circuits. The sensors furnished in the AR3200 include only the oscillator and require an external IS amplifier and trigger circuit. When a metal target is outside the sensing range of the device, the oscillator oscillates and requires a current of greater than 3.0 mA. When a metal target is within the sensing range, the oscillator stops oscillating and the current reduces to less than 1.0 mA. The external amplifiers and trigger circuits detect these differences in currents, thereby signaling the presence or absence of a metal target in range of the proximity sensors.
Diagnostic procedure
1. To verify operation of the device, monitor the LEDs located on the appropriate IS amplifier in the PLC assembly. Each amplifier channel contains two LED indicators. Yellow indicates the state of the proximity sensor (on or off) and red indicates the condition of the proximity sensor wiring.
2. A wiring short (current greater than 6.0 mA) or open condition (current less than 0.1 mA) causes the red indicator to illuminate. Check the field terminals and wire conductivity. If the red LED is not illuminated and the yellow LED does not change state with switch operation, measure the current in the proximity sensor.
3. Open one of the appropriate field terminals at the PLC assembly and, using a milliampere meter, measure the switch current. If the current is either 1.0 or 3.0 mA ± 0.5 and does not change when a metal target is moved in and out of range of the proximity switch, the proximity sensor is defective. If the above measurements are normal, the IS Amplifier may be defective.
SM00053, Rev D Troubleshooting 6-67
AR3200 control system
INTRINSIC SAFETY DEVICES
Zener safety barriers
The Zener safety barriers provide protection for the encoder located within a hazardous area. These safety barriers provide intrinsic safety (IS) by limiting current and voltage so that the energy released is insufficient to ignite explosive mixtures during operation or if there is a short circuit.
Diagnostic procedure
Measure the input voltage at terminals 1 and 2 of the 715 barrier. Input voltage should be 12 VDC.
The 715 Zener safety barrier is located between the power supply in the PLC box and the encoder. The 764 Zener safety barrier is located between the encoder and the PLC. Measure the output voltage of both barriers (terminals 3 and 4). Internal resistance of the barriers should cause a voltage drop.
A measured voltage of 12 V indicates an open circuit. If the voltage measured at the barrier is .7 V, check the barrier resistance. Remove the 12-volt power source and measure the resistance between terminals 1 and 3 of the affected barrier. The resistance should be between 100 (715 barrier) and 1000 (764 barrier) Ohms. An open circuit indicates a failed barrier.
6-68 AR3200 SM00053, Rev D
July 1, 2005
Intrinsically safe amplifiers
The control system contains four two-channel IS amplifiers (Figure 6-15). The barriers operate in one of two available modes. You can set them to respond either to open circuits or to closed circuits.
The topmost LED on each IS amplifier is a green power indicator. The middle pair of LEDs on each IS amplifier are red fault indicators-one LED for each channel. The bottom pair of LEDs on each IS amplifier are yellow output indicators-one LED for each channel.
Spinout Sensor
Torque WrenchPosition Sensor
Horizontal IndexSensor
Flow SwitchHorizontalPosition Sensor
Tool JointDetector Sensor
PS-MODE Switch
End of StrokeSensor
Figure 6-15. IS amplifiers
SM00053, Rev D Troubleshooting 6-69
AR3200 control system
Diagnostic procedure
Open the PLC assembly enclosure (only if the area is known to be free of explosive gas) and check the red status LEDs on each IS amplifier. If any red LED is on, a short or open circuit exists between the IS amplifier and the sensors. A green LED indicates that the power to the IS amplifiers is on.
z The Open/Short circuit diagnostic LED (red) does not work with the PS-MODE and flow switches. It works only with the proximity sensors.
Six of the channels are used for sensors and two are used for switches.
Each channel has a mode switch. The mode switches should be set as follows:
Mode 1: PS-MODE switch and flow switch circuits.
Mode 2: All other circuits.
Make sure that the channels operate properly by checking the yellow output status LEDs for the following:
1. The end-of-stroke sensor LED is off when the carriage is at least 3/4" above the end-of-stroke line.
2. The torque wrench position sensor LED is on at the extreme end-of-stroke (full makeup or full breakout).
3. The horizontal position sensor LED flickers when the AR3200 moves.
4. The flow switch LED turns off when the hydraulic flow (e.g., in foot drive motors) begins. The LED illuminates again when the flow stops.
5. The tool joint length sensor LED illuminates when the sensor detects the pipe. It will flash off momentarily as the tool joint detector encounters the box upset as it moves up the pipe.
6. The horizontal index sensor LED turns off momentarily when the AR3200 passes over the index slot.
7. The PS-MODE switch LED illuminates when the PS-MODE mode is selected.
8. The spinout sensor LED is normally illuminated during operation. It turns off momentarily when the tool has finished spinning. (The bump at thread out causes the target to move away from the sensor momentarily.)
Check the output status LED associated with each output. If the output is present at the driving source and there isn't a signal at the appropriate PLC terminal, the barrier in that circuit may be defective.
6-70 AR3200 SM00053, Rev D
July 1, 2005
Transformer isolated barriers
The potentiometer driver contains transformer isolated barriers that have a supply voltage of 20 - 35 VDC (terminal 7 and 8). The supply voltage is isolated from the input and output circuits. The excitation circuits are terminals 1 through 4. The input voltage to the transformer isolated barriers (terminals 7 and 8) is 24 V. When operating properly, an output voltage of 9.5 to 10.5 V is available to the potentiometer. Normally the voltage should be set to 10 V. It can, however, be adjusted to compensate for lead resistance.
Diagnostic procedure
A screw on top of the potentiometer allows you to adjust the voltage.
❏ See Engineering Drawing: AR3200 Remote controller (PLC) Assembly
1. Measure the barrier input voltage between terminals 11 and 12. It should be 24 VDC.
2. Open the knife switches in TB1 terminal blocks 31 through 35.
3. Check the barrier excitation voltage between terminals 1 and Earth. It should 10 V.
4. Close the knife switches in TB1 terminal blocks 31 through 35.
5. Check the excitation voltage again for a voltage drop. If a significant voltage drop is evident, either the barrier or switch has failed.
6. Check the output voltage of the tool joint length selector switch between terminal 3 and 4 on the potentiometer driver.
The voltage returned to the potentiometer driver for the tool joint length switch varies depending on the switch setting:
7. Check the barrier output voltage between terminals 7 and 8. The output voltage should correspond to the setting in the table above.
TOOL JOINT LENGTHSwitch setting
Output Voltage
MAN 0
8" 2
10" 4
12" 6
14" 8
HW 10
AR3200
AutomatedRoughneck
Supplemental Materials
July 1, 2005
7-2 AR3200 SM00053, Rev D
Supplemental Materials 7-3
Chapter 7 Contents
Chapter 7 Supplemental Materials
Supplement list .................................................................................................. 7-5
7-4 AR3200 SM00053, Rev D
July 1, 2005
Supplemental Materials 7-5
Chapter 7
Supplemental Materials
Supplement listThis section contains the following supplements:
❏ Safety Wiring Procedures, ASP00019
❏ AR3200 Commissioning Procedure, FIP00055
❏ Pipehandling Systems Preshipment Preparation Short & Long Term Storage, QA00016
❏ Hydraulic Fluid Cleanliness, SM00081
❏ Eaton Hydraulics Division, 2000 Series Char-Lynn Motors 005, VDR00058
❏ Eaton Hydraulics Division, 2000 Series Char-Lynn Motors 006, VDR00059
7-6 AR3200 SM00053, Rev D
July 1, 2005
HydraulicFluidCleanliness
SupplementSM00081
Rev. B.
2 Hydraulic Fluid Cleanliness SM00081-A
© Copyright 1979 and 1984 by Rexroth Corp.Excerpts used by persmission from the Rexroth Corporation,2315 City Line Road, Bethlehem, PA 18018.
SM00081-A Hydraulic Fluid Cleanliness 3
Contents
SupplementHydraulic Fluid Cleanliness ..................... 5
Hydraulic contamination .................................................... 5Solid contamination...................................................... 6
Classes of contamination......................................... 6Using ISO DIS 4406 ........................................ 8
Measuring the contamination of a system ............. 10Taking samples ............................................... 10Fluid sampling procedure ............................... 11
Analyzing the samples ........................................... 11
4 Hydraulic Fluid Cleanliness SM00081-A
SM00081-A Hydraulic Fluid Cleanliness 5
Supplement
Hydraulic FluidCleanliness
Hydraulic contamination
Varco recommends hydraulic fluid levels be maintained at acleanliness level of ISO 4406 15/12 or better. This documentpresents measurement and analysis criteria. When determiningcontamination of hydraulic fluids, you must consider the degreeof solid contamination.
6 Hydraulic Fluid Cleanliness SM00081-A
Solid contaminationThe contamination of hydraulic fluids by solid particles is coveredby a number of different classification systems:
❏ ISO DIS 4406
❏ MIL STD 1246 A
❏ NAS 1638
❏ SAE 749 D
❏ CETOP RP 70 H
Classes of contaminationThe various classes of contamination define the quantity ofparticles of a certain size in a 100 ml sample of fluid.
A classification is determined by counting and sizing thecontaminating solid particles. The classification is performedeither under a microscope, or by using an electronic particlecounter. The electronic counter method is more objective thanusing the microscope.
Above a dirt concentration of about 20 mg per liter, or if the fluidis very turbid, the contamination can only be ascertained byweight, i.e., by gravimetric analysis. However, with this method,the individual dirt particles cannot be classified.
Table 1 compares the various classification systems.
SM00081-A Hydraulic Fluid Cleanliness 7
Table 1. Comparison of contamination classifications
ISO DIS4406
orCetop RP
70 H
Particlesper ml
> 10 µm
ACFTDsolids
contentmg/L
MIL STD1246 A(1967)
NAS1638
(1964)
SAE749 D(1963)
26/23 140000 1000
25/23 85000 1000
23/20 14000 100 700
21/18 4500 12
20/18 2400 500
20/17 2300 11
20/16 1400 10
19/16 1200 10
18/15 580 9 6
17/14 280 300 8 5
16/13 140 1 7 4
15/12 70 6 3
14/12 40 200
14/11 35 5 2
13/10 14 0,1 4 1
12/9 9 3 0
18/8 5 2
10/8 3 100
10/7 2,3 1
10/6 1,4 0,01
9/6 1,2 0
8/5 0,6 00
7/5 0,3 50
6/3 0,14 0,001
5/2 0,04 25
Acc
epta
ble
rang
e fo
r V
arco
equ
ipm
ent
▼
▼
Acc
epta
ble
rang
e fo
r V
arco
equ
ipm
ent
▼
▼
8 Hydraulic Fluid Cleanliness SM00081-A
Using ISO DIS 4406
To determine the degree of contamination for the ISO DIS 4406,for example, first count all particles larger than 5 µm in the 100ml sample and give it a code number. Then count all particleslarger than 15µm and give them another code number (Figure 1).Using the example, if the sample contains 7,500 particles over5 µm, the code number is 13. If the particles larger than 15 µmis 300, the code number is 9. The code number for this samplewould be stated as 13/9.
These code numbers form the designation of the sample. Table 2lists the contamination figures and their coding.
Figure 1. Contamination coding to ISO DIS 4406
SM00081-A Hydraulic Fluid Cleanliness 9
Table 2. Contamination data and short form coding
No. of particles per 100 ml
over 5 um over 15 um
Code more than and up to more than and up to
20/17 500 k 1 M 64 k 130 k
20/16 500 k 1 M 32 k 64 k
20/15 500 k 1 M 16 k 32 k
20/14 500 k 1 M 8 k 16 k
19/16 250 k 500 k 32 k 64 k
19/15 250 k 500 k 16 k 32 k
19/14 250 k 500 k 8 k 16 k
19/13 250 k 500 k 4 k 8 k
18/15 130 k 250 k 16 k 32 k
18/14 130 k 250 k 8 k 16 k
18/13 130 k 250 k 4 k 8 k
18/12 130 k 250 k 2 k 4 k
17/14 64 k 130 k 8 k 16 k
17/13 64 k 130 k 4 k 8 k
17/12 64 k 130 k 2 k 4 k
17/11 64 k 130 k 1 k 2 k
16/13 32 k 64 k 4 k 8 k
16/12 32 k 64 k 2 k 4 k
16/11 32 k 64 k 1 k 2 k
16/10 32 k 64 k 500 1 k
15/12 16 k 32 k 2 k 4 k
15/11 16 k 32 k 1 k 2 k
15/10 16 k 32 k 500 1 k
15/9 16 k 32 k 250 500
14/11 8 k 16 k 1 k 2 k
14/10 8 k 16 k 500 1 k
14/9 8 k 16 k 250 500
14/8 8 k 16 k 130 250
13/10 4 k 8 k 500 1 k
13/9 4 k 8 k 250 500
13/8 4 k 8 k 130 250
12/9 2 k 4 k 250 500
12/8 2 k 4 k 130 250
11/8 1 k 2 k 130 250
10 Hydraulic Fluid Cleanliness SM00081-A
Measuring the contamination of a systemSolid particle contamination is measured by taking a sample offluid from the hydraulic system and analyzing it.
The analysis can reveal the following:
❏ Solid particle contamination of fluid delivered by suppliers
❏ Effectiveness of the system filters
❏ Flushing time when commissioning a system
❏ State of the system and any possible damage to componentswhen making regular checks
Taking samples
Take a sample from a moving fluid (known as dynamic sampling)(Figure 2).
Sampling point: Take the sample within a system that is operatingand which contains turbulent flow. (See ISO 4021.)
Figure 2. Taking a sample
SM00081-A Hydraulic Fluid Cleanliness 11
Fluid sampling procedure
Apply the following general measures when taking a sample:
❏ Before taking the sample, carefully flush out the samplingdevice with clean solvent.
❏ Use only sample bottles that have been cleaned with freshsolvent.
❏ Remove any remaining solvent before taking the sample.
❏ Allow at least two liters of system fluid to flush through thesampling device before taking the actual sample.
❏ Take a zero sample. This sample is not used for the analysisbecause it is not representative of the system contamination.
❏ Place the fluid to be analyzed into a new, clean sample bottle.The protective foil on the bottle should only be lifted.
Analyzing the samplesAnalyzing the fluid samples involves using a microscope to makea quick estimate of the amount of solid particle contamination.From this assessment, you can roughly assess the state of thesystem.
e Only properly trained personnel should be allowed to take the fluidsamples. Errors in sampling procedures can greatly affectcontamination classes below NAS 6.
To avoid errors in sampling, conduct particle counting on site.Do not allow rig personnel to attempt to check the samples at thetime of sampling. Send the samples to an appropriate institute fortesting.
Usually, samples are analyzed by means of an electronic particlecounter. These particle counters are employed by major users ofhydraulics, manufacturers of hydraulic filters, and by variousinstitutions. Since testing by an outside source may not be easilyaccessible from a rig, you can make a quick assessment of thefluid samples on the spot by using the assessment test charts inthis document.
z Mobile laboratory services also can perform the measurements forcustomers.
12 Hydraulic Fluid Cleanliness SM00081-A
AR3200
AutomatedRoughneck
Drawings
July 1, 2005
8-2 AR3200 SM00053, Rev D
8-3
Chapter 8 Contents
Chapter 8 DrawingsDrawings by assembly ...................................................................................... 7-5Drawings in numerical order ............................................................................. 7-7
8-4 AR3200 SM00053, Rev C
July 1, 2005
Drawings 8-5
Chapter 8
Drawings
This chapter provides a list of drawings included in this manual. The drawings are arranged both by assembly and numerically.
Drawings by assemblyAssembly
AR3200 Electrical Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107411
AR3200 Automated Iron Roughneck Assembly. . . . . . . . . . . . . . . 107413
Torque Wrench Jaw Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86711
SSW-50 Spinning Wrench Assembly . . . . . . . . . . . . . . . . . . . . . . . . 86990
TW-102 Torque Wrench Assembly . . . . . . . . . . . . . . . . . . . . . . . . . 89650
Foot Frame Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71446
IBOP Installation Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87864
Std. Tilt Lever Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87005
Reverse Tilt Lever Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87816
Hydraulic Subassembly
Valve Manifold Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86700
Inlet Manifold Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86957
8-6 AR3200 SM00053, Rev D
July 1, 2005
Hydraulic Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86965
Hydraulic Motor Arm Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87047
Manual Control Panel (EEx) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107535
Manual Control Panel (UL). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107729
Installation
AR3200 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107808
AR3200 Electrical Installation Kit . . . . . . . . . . . . . . . . . . . . . . . . .107412
AR3200 Interconnect Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . .107499
AR3200 Remote Controller (PLC) Assembly. . . . . . . . . . . . . . . . . . 99435
Rig Floor-59" Outside Rail Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86714
Hinged Cog Drive Adapter Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . 86911
Miscellaneous
AR3200 Derrick J-Box Assembly. . . . . . . . . . . . . . . . . . . . . . . . . .107154
AR3200 Derrick Plate Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . 107151
AR3200 Electrical Service Loop. . . . . . . . . . . . . . . . . . . . . . . . . . .108592
AR3200 Hydraulic Service Loop . . . . . . . . . . . . . . . . . . . . . . . . . . 108593
AR3200 I.S. Electrical Service Loop . . . . . . . . . . . . . . . . . . . . . . .108594
AR3200 Flowcharts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108102
AR3200 Tool J-Box Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . .107462
AR3200 Solenoid Driver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99871
AR3200 Switch Replacements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109835
Instruction Plate, Jaw Sizing Data. . . . . . . . . . . . . . . . . . . . . . . . . . . 87519
Linear Position Slave Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96975
Spares Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108941
Spin Out Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93788
SM00053, Rev D Drawings 8-7
Drawings in numerical orderFoot Frame Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71446
Valve Manifold Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86700
Torque Wrench Jaw Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86711
Rig Floor-59" Outside Rail Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86714
Hinged Cog Drive Adapter Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . 86911
Inlet Manifold Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86957
Hydraulic Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86965
SSW-50 Spinning Wrench Assembly . . . . . . . . . . . . . . . . . . . . . . . . 86990
Std. Tilt Lever Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87005
Hydraulic Motor Arm Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87047
Instruction Plate, Jaw Sizing Data . . . . . . . . . . . . . . . . . . . . . . . . . . 87519
Reverse Tilt Lever Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87816
IBOP Installation Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87864
TW-102 Torque Wrench Assembly . . . . . . . . . . . . . . . . . . . . . . . . . 89650
Spin Out Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93788
Linear Position Slave Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96975
AR3200 Remote Controller (PLC) Assembly . . . . . . . . . . . . . . . . . 99435
AR3200 Solenoid Driver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99871
AR3200 Derrick Plate Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . 107151
AR3200 Derrick J-Box Assembly . . . . . . . . . . . . . . . . . . . . . . . . . 107154
AR3200 Electrical Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107411
AR3200 Electrical Installation Kit . . . . . . . . . . . . . . . . . . . . . . . . . 107412
AR3200 Automated Iron Roughneck Assembly. . . . . . . . . . . . . . . 107413
AR3200 Tool J-Box Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107462
AR3200 Interconnect Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107499
Manual Control Panel (EEx). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107535
Manual Control Panel (UL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107729
AR3200 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107808
AR3200 Flowcharts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108102
AR3200 Electrical Service Loop . . . . . . . . . . . . . . . . . . . . . . . . . . 108592
AR3200 Hydraulic Service Loop . . . . . . . . . . . . . . . . . . . . . . . . . . 108593
AR3200 I.S. Electrical Service Loop . . . . . . . . . . . . . . . . . . . . . . . 108594
8-8 AR3200 SM00053, Rev D
July 1, 2005
Spares Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108941
AR3200 Switch Replacements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109835