smartpack new
DESCRIPTION
PowerTRANSCRIPT
June 2006
2
Eltek
Scaleable and flexible control module for the entire Eltek product range
3
Eltek
Small but powerfulSmall but powerful
44mm
109 mm
144 mm
< 300g
4
Eltek
”Traffic Light”LEDs
Front PanelStandardFront PanelStandard
2x16 character display
3 button Keypad
USB Port
CAN Bus IDDIP switches
5
Eltek
Rear PanelCAN BusRear PanelCAN Bus
CAN bus
Part No : 242100.110(RoHS compliant)
120 ohm term. required at each end
ID based serial bus communications
Max 8 Smartpack
Max 50 Rectifiers
6
Eltek
Rear PanelBattery MonitoringRear PanelBattery Monitoring
Battery Monitoring
Part No : 242100.110(RoHS compliant)
Con 4 : StandardCon 3 : Extended
• Symmetry measurement
• 8 strings mid point or2 strings 12V block
• Temp sense
7
Eltek
Rear PanelInternal SystemRear PanelInternal System
Internal System
Part No : 242100.110(RoHS compliant)
System measurements
Unit Power
2xLVD control (Latched)
Battery fuse fail
8
Eltek
Rear PanelAlarm I/ORear PanelAlarm I/O
Alarm I/O
Part No : 242100.110(RoHS compliant)
Con 1 (standard):-
2 + 2 relay input / output
Con 2 (extended):-
4 + 4 relay input / output
9
Eltek
RS-232 OptionRS-232 Option
RS-232 mounted
Part No : 242100.111(RoHS compliant)
•Enables connection of Standalone Webpower or modem
•Rear position : Replaces extended Battery symmetry card
Part No : 242100.112(RoHS compliant)
10
Eltek
1. Remove 4 chassis screws2. Remove top D-Sub fixings (CON 2 & 3).3. Lift top cover from the front.(Re-assemble in reverse order)
Opening the SmartpackOpening the Smartpack
11
Eltek
Rear PanelEmbedded WebpowerRear PanelEmbedded Webpower
Embedded
WebPower
Part No : 242100.113(RoHS compliant)
Ethernet interface of remote monitoring of SmartpackIs possible to “tunnel” Powersuite remotely also.
12
Eltek
FunctionalityFunctionality
Battery monitoring and testing
Temperature compensated charging
Battery lifetime indication
Alarm/event log (1000) with time and date
And much more ….
13
Eltek
ScalabilityScalability
Smartpack MasterSmartpack Slave n
System functionalityVoltage input 1
Symmetry inputs 8 (2x4x12V)
Current inputs 2
Temperature inputs 2
General purpose inputs 6
Load fuse input 1
Batt fuse input 2
Relay outputs 6
Contactor control 2+
System functionalityVoltage inputs 2
Symmetry inputs 16 (4x4x12V)
Current inputs 4
Temperature inputs 4
General purpose inputs 12
Load fuse input 2
Batt fuse input 4
Relay outputs 12
Contactor control 4+
System functionality with 8 modulesVoltage inputs 8
Symmetry inputs 64 (16x4x12V)
Current inputs 2x8
Temperature inputs 2x8
General purpose inputs 6x8
Load fuse input 1x8
Batt fuse input 2x8
Relay outputs 6x8
Contactor control 2+x8
Smartpack Slave 1
CAN/Power bus
14
Eltek
ConnectivityBatteryConnectivityBattery
CON3 & CON4 – Battery Connections
Temp SenseCable
Pin Function
1 Symmetry I/P 1
2 Symmetry I/P 2
3 Symmetry I/P 3
4 Symmetry I/P 4
5 Symmetry I/P 5
6 Symmetry I/P 6
7 Symmetry I/P 7
8 Symmetry I/P 8
9-10 Con 3 : Temp sense 2Con 4 : Temp sense 1
11 - 14 Con 3 – 2nd batt current, batt fuseCon 4 : Not used
15
Eltek
Symmetry measurement options
ConnectivitySymmetryConnectivitySymmetry
16
Eltek
ConnectivitySystemConnectivitySystem
CON5 – System ConnectionsPin Function
1 Positive Input
2 Negative Input
3 Batt Current +ve
4 Batt Current -ve
5 Batt Fuse +ve
6 Batt Fuse -ve
7 Load Fuse Fail
8 LVD1 Active
9 LVD1 Common
10 LVD2 Active
11 LVD2 CommonSystem Connection Card. Art 200625
17
Eltek
ConnectivitySystemConnectivitySystem
System card configuration
JP1-48v system = 1-2 +24v system = 2-3
JP2-48v system = ‘Neg’+24v system = ‘Pos’
18
Eltek
Connectivity Latched ContactorsConnectivity Latched Contactors
A latching contactor changes state only when a reversed pulse voltage is applied to the coil.
Protection Diode
19
Eltek
ConnectivityExternal Alarm I/OConnectivityExternal Alarm I/O
CON1 & CON2 – I/O Connections
Pin Function
1 - 2 Alarm input 1 ( + / -)
3 – 4 Alarm input 2 ( + / -)
5 - 7 Alarm output 1 ( NO /C / NC)
8 - 10 Alarm output 2 ( NO /C / NC)
1 - 2 Alarm input 3 ( + / -)
3 - 4 Alarm input 4 ( + / -)
5 - 6 Alarm input 5 ( + / -)
7 - 8 Alarm input 6 ( + / -)
9 - 11 Alarm output 3 ( NO /C / NC)
12 - 14 Alarm output 4 ( NO /C / NC)
15 - 17 Alarm output 5 ( NO /C / NC)
18 - 20 Alarm output 6 ( NO /C / NC)Alarm Output & Input Card
Art 105954
20
Eltek
Smartpack Extended Master Smartnode
CAN/Power bus Customer equipment
Convert PCOMM to Customer specific Protocol
Part no: 242100.200
Communicating with Smartpack on CAN bus
RS232 and RS485 serial interface as standard
SmartnodeSmartnode
Customer bus (RS 485)
Smartpack has only PCOMM protocol
21
Eltek
PowerSuitePowerSuite
Explorer oriented easy to use PC SW
USB gives simple access.
Wide functionality with clear graphic presentation.
22
Eltek
PowerSuitePowerSuite
Live Demo
29
Eltek
End of PresentationEnd of Presentation
Let’s us know if you found this presentation useful or would like more information.
Eltek values your feedback.